Attachment 4 - Concept Floor Plan.pdf
PDF 3 MB Posted
- Solicitation number
- W9123821R0001
About this file
This document package includes conceptual floor plans and an overview of a solicitation for a design-build project. The Army Corps of Engineers is seeking proposals to design and construct a 185,000 square foot Software Sustainment Center at Hill Air Force Base in Utah. The facility will include computer labs, auditorium-style conference rooms, and multiple secured office spaces. An attached 560-stall parking garage is also required. Design and construction services will cover civil, architectural, structural, mechanical, electrical and communications work. The estimated value of construction is between $100-$250 million. Offerors should have a North American Industry Classification System code of 236220 for commercial and industrial building construction and a size standard of $39.5 million or less. Proposals are due in accordance with Defense Federal Acquisition Regulation Supplement 236.204(iii).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
O U
T H
P A
C
IF
IC
D
IV
IS
IO
N
S A
C R
A M
E N
T O
D
IS
T R
IC
T
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
SACRAMENTO DISTRICT
P R
O J E
C T
N U
M B
E R
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
2 864 10
E
F
G
F O
R O
F F
IC
IA
L U
S E
O N
L Y
DRAWINGS ARE INTENDED AS A SUPPLEMENT TO
SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL
BASIS OF DESIGN. FINAL FLOOR PLANS AND THE
FACILITY FINAL DESIGN REQUIREMENTS (TYPE,
QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE
RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR
AND THE DESIGNER OF RECORD (DOR). CONCEPT
DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;
THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND
COORDINATING FINAL DESIGN REQUIREMENTS WITH
APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,
AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY
CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL
REQUIRE APPROVAL OF THE CONTRACTING OFFICER.
/3
/2
:0
:1
P
M
A-200
D e s ig n e r
C h e c k e r
A u th o r
F E
B R
U A
R Y
P ro j.
N o
A C
E N
T R
A L
H
IL
L A
IR
F
O R
C E
B A
S E
U
T A
H
E X
T E
R
IO
R M
A S
S
IN
G
G R
O U
N D
B A
S E
D S
T R
A T
E G
IC
D
E F
E N
S E
SCALE
A7
EXTERIOR MASSING
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
For Refe ren ce nly
PLAN LEGEND
SECURE BOUNDARY
EXIT ONLY / IDS
CARD READER / X-10 LOCK / KEY PAD
CARD READER
DOOR ACCESS CONTROL
E/I
CX
C
SEE A-011 FOR
UPPER LEVEL
SEATING
LOADING
AREA
TO PARKING
GARAGE
1 3 6 7 8 9 10 11 134 12
A
B
C
D
E
G
F
H
J.1
L
M
N
P
16' - 6" 11' - 6" 16' - 0" 22' - 0" 30' - 0" 22' - 6" 17' - 6" 28' - 0" 26' - 0" 26' - 0" 30' - 0" 30' - 0"
276' - 0"
K
J
7.1
SURVEILLANCE
OFFICE
OFFICE AQUISITION ROOM
OFFICE OFFICE COMM
OFFICE
OFFICE
TRAINING ROOM
MEETING MEETING
CONFERENCE
(30-PERSON)
MEETINGMEETING
OFFICE MAIL RECEIVING BAY
EM ELEC
MECHANICAL ROOM
UPS ELEC
ELEC
UPS ELEC
ELEV MACHCOMM
ELEC
VESTSTOR
STAIR 3 FREIGHT
ELEC
VEST
STOR
VEST
FITNESS
MEN WOMEN
UP UPUP
CORR
LOCKERS
BADGE WAITINGCOMM
OFFICE
OFFICE OFFICE
CONFERENCE
(20-PERSON)
ADMINWAIT
STAIR 1
BREAK
SEC WAIT
BADGESEC BRIEF
COMM
SECURITY POST
HSI LAB
DESTRUC.
CONFERENCE
(30-PERSON)
OFFICE
UNISEX
COMM
ALARM
COMSEC
DUP
POST SECURITY
ENGINEERING
SOFTWARE SUPPORT
NEW HIRE
MULTI-USE
COFFEE
MECH
RESTRM
RESTRM
MOTHER
JAN
WOMEN
MEN
ELEC
COMM
CORR
ELEV
SOFTWARE TEAM
ROOM
STAIR 2
BREAK / QOL
BUILDING SUPPORT
CIRCULATION
ENG SOFTWARE SUPPORT
FACILITY SUPPORT
FITNESS
HSI LAB
LEADERSHIP OFFICE
MECH, ELEC, COMM
NEW HIRE
POST SECURITY
PROGRAM SECURITY OFFICE
SECURITY
SHARED SPACE
SOFTWARE TEAM ROOM
E/I
CX
C
C
C
C
C
C
C
C C
E/I
C
C
C C
C
C
C
E/I
E/I E/I
STOR
C
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
T H
P A
C
IF
IC
D
IV
IS
IO
N
S A
C R
A M
E N
T O
D
IS
T R
IC
T
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
SACRAMENTO DISTRICT
P R
O J E
C T
N U
M B
E R
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
2 864 10
E
F
G
F O
R O
F F
IC
IA
L U
S E
O N
L Y
DRAWINGS ARE INTENDED AS A SUPPLEMENT TO
SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL
BASIS OF DESIGN. FINAL FLOOR PLANS AND THE
FACILITY FINAL DESIGN REQUIREMENTS (TYPE,
QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE
RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR
AND THE DESIGNER OF RECORD (DOR). CONCEPT
DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;
THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND
COORDINATING FINAL DESIGN REQUIREMENTS WITH
APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,
AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY
CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL
REQUIRE APPROVAL OF THE CONTRACTING OFFICER.
/3
/2
:0
:0
P
M
/1
A-010
J B
L A
N D
C h e c k e r
J B
L A
N D
F E
B R
U A
R Y
P ro j.
N o
A C
E N
T R
A L
H
IL
L A
IR
F
O R
C E
B A
S E
U
T A
H
O V
E R
A L L G
R O
U N
D F
L O
O R
P L A
N
G R
O U
N D
B A
S E
D S
T R
A T
E G
IC
D
E F
E N
S E
SCALE 1/16" = 1'-0"
OVERALL GROUND FLOOR PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
0 8' 16' 32'
N
GROSS AREA SCHEDULE
AREA SQUARE FOOTAGE
LEVEL 01 53,922 SF
LEVEL 02 42,784 SF
LEVEL 03 40,044 SF
LEVEL 04 39,982 SF
TOTAL 176,731 SFFor Refe ren ce
EXIT ONLY / IDS
CARD READER / X-10 LOCK / KEY PAD
CARD READER
DOOR ACCESS CONTROL
E/I
CX
C
1 3 6 7 8 9 10 11 134 12
A
B
C
D
E
G
F
H
J.1
L
M
N
P
2 5
K
J
7.1
COMM
COMM
COMM
MISSION DEFENSE
OPS CENTER
OFFICE OFFICE
BUILDING SUPPORT
CIRCULATION
HSI LAB
MECH, ELEC, COMM
MISSION DEFENSE CYBER SECURITY
MISSION DEFENSE ENGINEERING
MISSION DEFENSE INTEL GROUP
MISSION DEFENSE NUCLEAR SECURITY
MISSION DEFENSE OPS CENTER
SECURITY
SHARED SPACE
SOFTWARE TEAM ROOM
STAIR 1
STAIR 3
OPEN TO BELOW
OPEN TO BELOW
OPEN TO BELOW
COMM
CONFERENCE
(20-PERSON)
OFFICE
OFFICE
OFFICE COMM
ALARM
OPS FLOOR
SUPPORT
CONFERENCE
(20-PERSON)
MD TDY STATIONS
COMM ELEC
MECH
UNISEX
UNISEX
MOTHER
MEN
ELEC
WOMEN ELEV
MISSION DEFENSE
ENGINEERING
MISSION DEFENSE
CYBER SECURITY
MISSION DEFENSE
NUCLEAR SECURITY
STOR
JAN
STAIR 2
FREIGHT
ELEC
MD OPS TRAINER
OFFICE
CONFERENCE
(30-PERSON)
CONFERENCE
(20-PERSON)
ALARM
VISITOR WORK
SPACE
MD INTELSECURE POST
TRAINER SIM
SUPPORT
MD OPS
CMD OFFICE
CORR
CORR
CONFERENCE
(20-PERSON)
MD INTEGRATION
TEAM
MD ADVERSARY
EMULATION
CX
C
CC
C C
C
C
C
C
C
C
CC
C
C
C
C
C
C COFFICE
CX
CORR
CORR
LOCKERS
C
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
T H
P A
C
IF
IC
D
IV
IS
IO
N
S A
C R
A M
E N
T O
D
IS
T R
IC
T
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
SACRAMENTO DISTRICT
P R
O J E
C T
N U
M B
E R
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
2 864 10
E
F
G
F O
R O
F F
IC
IA
L U
S E
O N
L Y
DRAWINGS ARE INTENDED AS A SUPPLEMENT TO
SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL
BASIS OF DESIGN. FINAL FLOOR PLANS AND THE
FACILITY FINAL DESIGN REQUIREMENTS (TYPE,
QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE
RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR
AND THE DESIGNER OF RECORD (DOR). CONCEPT
DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;
THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND
COORDINATING FINAL DESIGN REQUIREMENTS WITH
APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,
AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY
CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL
REQUIRE APPROVAL OF THE CONTRACTING OFFICER.
/3
/2
:0
:3
P
M
/1
A-011
D e s ig n e r
C h e c k e r
A u th o r
F E
B R
U A
R Y
P ro j.
N o
A C
E N
T R
A L
H
IL
L A
IR
F
O R
C E
B A
S E
U
T A
H
O V
E R
A L L S
E C
O N
D F
L O
O R
P L A
N
G R
O U
N D
B A
S E
D S
T R
A T
E G
IC
D
E F
E N
S E
0 8' 16' 32'
N
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE 1/16" = 1'-0"
OVERALL SECOND FLOOR PLAN For Refe ren ce
EXIT ONLY / IDS
CARD READER / X-10 LOCK / KEY PAD
CARD READER
DOOR ACCESS CONTROL
E/I
CX
C
1 3 6 7 8 9 10 11 134 12
A
B
C
D
E
G
F
H
J.1
L
M
N
P
2 5
K
J
7.1
16' - 6" 11' - 6" 16' - 0" 22' - 0" 30' - 0" 22' - 6" 17' - 6" 28' - 0" 26' - 0" 26' - 0" 30' - 0" 30' - 0"
276' - 0"
BUILDING SUPPORT
CIRCULATION
MECH, ELEC, COMM
MULTI-TEAM
RESTROOMS
SECURITY
SHARED SPACE
SMALL TEAM
STAND ALONE ALARMED ROOM
SYSTEM ADMIN / SERVER LAB
MULTI-TEAM
FREIGHT
OUTDOOR
PC BUILD
IT STOR
SERVER
SERVER SUPPORT
SERVER MAINT
ELEC
SERVER MAINT
SERVER
TEST LAB
MULTI-TEAM
SMALL TEAM
SMALL TEAM
SMALL TEAM
ELEC ELEC
SERVER
COMM
ALARM
COMM
SERVER SUPPORT
OFFICE
ALARM OFFICE OFFICE
CONFERENCE
(10-PERSON)
SECURITY POST
STAND ALONE
ALARM ROOM
COMM ELEC
TEST LAB
COMM
OFFICE
COMM
CONFERENCE
(12-PERSON)
CONFERENCE
(8-PERSON)
CONFERENCE
(8-PERSON)
OFFICE
CONFERENCE
(8-PERSON)
CONFERENCE
(8-PERSON)
OFFICE
ELEC STAIR 3
CORR
CORR
MECH
MOTHER
UNISEX
UNISEXELEC
COMM
MEN
WOMEN
ELEV
STOR
JAN
STAIR 1
CX
C C
C
C
C C
C
C
C
C C C
C
C
C
C
C
C
C
C
C
C
C
STAIR 2
ROOF
BELOW
ROOF
BELOW
ROOF
BELOW
LOCKERS
C
CX
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
T H
P A
C
IF
IC
D
IV
IS
IO
N
S A
C R
A M
E N
T O
D
IS
T R
IC
T
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
SACRAMENTO DISTRICT
P R
O J E
C T
N U
M B
E R
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
2 864 10
E
F
G
F O
R O
F F
IC
IA
L U
S E
O N
L Y
DRAWINGS ARE INTENDED AS A SUPPLEMENT TO
SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL
BASIS OF DESIGN. FINAL FLOOR PLANS AND THE
FACILITY FINAL DESIGN REQUIREMENTS (TYPE,
QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE
RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR
AND THE DESIGNER OF RECORD (DOR). CONCEPT
DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;
THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND
COORDINATING FINAL DESIGN REQUIREMENTS WITH
APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,
AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY
CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL
REQUIRE APPROVAL OF THE CONTRACTING OFFICER.
/3
/2
:0
:4
P
M
/1
A-012
D e s ig n e r
C h e c k e r
A u th o r
F E
B R
U A
R Y
P ro j.
N o
A C
E N
T R
A L
H
IL
L A
IR
F
O R
C E
B A
S E
U
T A
H
O V
E R
A L L T
H
IR
D F
L O
O R
P L A
N
G R
O U
N D
B A
S E
D S
T R
A T
E G
IC
D
E F
E N
S E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE 1/16" = 1'-0"
OVERALL THIRD FLOOR PLAN
0 8' 16' 32'
NFor Refe ren ce
EXIT ONLY / IDS
CARD READER / X-10 LOCK / KEY PAD
CARD READER
DOOR ACCESS CONTROL
E/I
CX
C 1 3 6 7 8 9 10 114 12
C
D
E
G
F
H
J.1
L
M
N
P
2 5
K
J
7.1
PATIO
BELOW
16' - 6" 11' - 6" 16' - 0" 22' - 0" 30' - 0" 22' - 6" 17' - 6" 28' - 0" 26' - 0" 26' - 0" 30' - 0"
PC BUILD
MULTI-TEAM
CONFERENCE
(10-PERSON)
COMM
ALARM
CORR
BUILDING SUPPORT
CIRCULATION
MECH, ELEC, COMM
MULTI-TEAM
SECURITY
SHARED SPACE
SMALL TEAM
STAND ALONE ALARMED ROOM
SYSTEM ADMIN / SERVER LAB
SERVER MAINT
SERVER
CONFERENCE
(30-PERSON)
ELEC
TEST LAB
OFFICE
SYSTEM ENG
SERVER
ELEC
IT STOR
COMM
SMALL TEAM
SMALL TEAM
SMALL TEAM
OFFICE
COMM
COMM ELEC
STAND ALONE
ALARM ROOM
ALARM OFFICEOFFICE
TEST LAB
SERVER SUPPORT
OFFICE
SERVER SUPPORT
MULTI-TEAM
MECH
STOR
JAN
UNISEX
UNISEX
MEN
WOMENMOTHER
ELEC
CORR
COMM
SECURITY POST
ELEV
CONFERENCE
(8-PERSON)
CONFERENCE
(8-PERSON)
OFFICE
CONFERENCE
(10-PERSON)
CONFERENCE
(8-PERSON)
OFFICE
FREIGHTELEC STAIR 3
CONFERENCE
(12-PERSON)
OFFICE
COMM
STAIR 1
C
C
C
C
C
C
C
C
C
C C
CX
C
C
CC
C
C
C
C
C C
C
C
C
E/I
STAIR 2
C
CX
LOCKERS
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C
O N
T R
A C
T N
O
A F
D R
A W
IN
G
C O
D E
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
U
T H
P A
C
IF
IC
D
IV
IS
IO
N
S A
C R
A M
E N
T O
D
IS
T R
IC
T
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
US ARMY CORPS
OF ENGINEERS
SACRAMENTO DISTRICT
P R
O J E
C T
N U
M B
E R
SHEET ID
N O
T F
O R
C O
N S
T R
U C
T
IO
N
2 864 10
E
F
G
F O
R O
F F
IC
IA
L U
S E
O N
L Y
DRAWINGS ARE INTENDED AS A SUPPLEMENT TO
SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL
BASIS OF DESIGN. FINAL FLOOR PLANS AND THE
FACILITY FINAL DESIGN REQUIREMENTS (TYPE,
QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE
RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR
AND THE DESIGNER OF RECORD (DOR). CONCEPT
DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;
THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND
COORDINATING FINAL DESIGN REQUIREMENTS WITH
APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,
AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY
CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL
REQUIRE APPROVAL OF THE CONTRACTING OFFICER.
/3
/2
:0
:4
P
M
/1
A-013
D e s ig n e r
C h e c k e r
A u th o r
F E
B R
U A
R Y
P ro j.
N o
A C
E N
T R
A L
H
IL
L A
IR
F
O R
C E
B A
S E
U
T A
H
O V
E R
A L L F
O U
R T
H F
L O
O R
P L A
N
G R
O U
N D
B A
S E
D S
T R
A T
E G
IC
D
E F
E N
S E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SCALE 1/16" = 1'-0"
OVERALL FOURTH FLOOR PLAN
0 8' 16' 32'
NFor Refe ren ce
File details come from the government source that posted it. Updated .