This document package includes conceptual floor plans and an overview of a solicitation for a design-build project. The Army Corps of Engineers is seeking proposals to design and construct a 185,000 square foot Software Sustainment Center at Hill Air Force Base in Utah. The facility will include computer labs, auditorium-style conference rooms, and multiple secured office spaces. An attached 560-stall parking garage is also required. Design and construction services will cover civil, architectural, structural, mechanical, electrical and communications work. The estimated value of construction is between $100-$250 million. Offerors should have a North American Industry Classification System code of 236220 for commercial and industrial building construction and a size standard of $39.5 million or less. Proposals are due in accordance with Defense Federal Acquisition Regulation Supplement 236.204(iii).

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

O U

T H

P A

C

IF

IC

D

IV

IS

IO

N

S A

C R

A M

E N

T O

D

IS

T R

IC

T

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

US ARMY CORPS

OF ENGINEERS

SACRAMENTO DISTRICT

P R

O J E

C T

N U

M B

E R

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

2 864 10

E

F

G

F O

R O

F F

IC

IA

L U

S E

O N

L Y

DRAWINGS ARE INTENDED AS A SUPPLEMENT TO

SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL

BASIS OF DESIGN. FINAL FLOOR PLANS AND THE

FACILITY FINAL DESIGN REQUIREMENTS (TYPE,

QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE

RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR

AND THE DESIGNER OF RECORD (DOR). CONCEPT

DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;

THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND

COORDINATING FINAL DESIGN REQUIREMENTS WITH

APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,

AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY

CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL

REQUIRE APPROVAL OF THE CONTRACTING OFFICER.

/3

/2

:0

:1

P

M

A-200

D e s ig n e r

C h e c k e r

A u th o r

F E

B R

U A

R Y

P ro j.

N o

A C

E N

T R

A L

H

IL

L A

IR

F

O R

C E

B A

S E

U

T A

H

E X

T E

R

IO

R M

A S

S

IN

G

G R

O U

N D

B A

S E

D S

T R

A T

E G

IC

D

E F

E N

S E

SCALE

A7

EXTERIOR MASSING

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

For Refe ren ce nly

PLAN LEGEND

SECURE BOUNDARY

EXIT ONLY / IDS

CARD READER / X-10 LOCK / KEY PAD

CARD READER

DOOR ACCESS CONTROL

E/I

CX

C

SEE A-011 FOR

UPPER LEVEL

SEATING

LOADING

AREA

TO PARKING

GARAGE

MAIL

1 3 6 7 8 9 10 11 134 12

A

B

C

D

E

G

F

H

J.1

L

M

N

P

16' - 6" 11' - 6" 16' - 0" 22' - 0" 30' - 0" 22' - 6" 17' - 6" 28' - 0" 26' - 0" 26' - 0" 30' - 0" 30' - 0"

276' - 0"

K

J

7.1

SURVEILLANCE

OFFICE

OFFICE AQUISITION ROOM

OFFICE OFFICE COMM

OFFICE

OFFICE

TRAINING ROOM

MEETING MEETING

CONFERENCE

(30-PERSON)

MEETINGMEETING

OFFICE MAIL RECEIVING BAY

EM ELEC

MECHANICAL ROOM

UPS ELEC

ELEC

UPS ELEC

ELEV MACHCOMM

ELEC

VESTSTOR

STAIR 3 FREIGHT

ELEC

VEST

STOR

VEST

FITNESS

MEN WOMEN

UP UPUP

CORR

LOCKERS

BADGE WAITINGCOMM

OFFICE

OFFICE OFFICE

CONFERENCE

(20-PERSON)

ADMINWAIT

STAIR 1

BREAK

SEC WAIT

BADGESEC BRIEF

COMM

SECURITY POST

HSI LAB

DESTRUC.

CONFERENCE

(30-PERSON)

OFFICE

UNISEX

COMM

ALARM

COMSEC

DUP

POST SECURITY

ENGINEERING

SOFTWARE SUPPORT

NEW HIRE

MULTI-USE

COFFEE

MECH

RESTRM

RESTRM

MOTHER

JAN

WOMEN

MEN

ELEC

COMM

CORR

ELEV

SOFTWARE TEAM

ROOM

STAIR 2

BREAK / QOL

BUILDING SUPPORT

CIRCULATION

ENG SOFTWARE SUPPORT

FACILITY SUPPORT

FITNESS

HSI LAB

LEADERSHIP OFFICE

MECH, ELEC, COMM

NEW HIRE

POST SECURITY

PROGRAM SECURITY OFFICE

SECURITY

SHARED SPACE

SOFTWARE TEAM ROOM

E/I

CX

C

C

C

C

C

C

C

C C

E/I

C

C

C C

C

C

C

E/I

E/I E/I

STOR

C

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

T H

P A

C

IF

IC

D

IV

IS

IO

N

S A

C R

A M

E N

T O

D

IS

T R

IC

T

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

US ARMY CORPS

OF ENGINEERS

SACRAMENTO DISTRICT

P R

O J E

C T

N U

M B

E R

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

2 864 10

E

F

G

F O

R O

F F

IC

IA

L U

S E

O N

L Y

DRAWINGS ARE INTENDED AS A SUPPLEMENT TO

SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL

BASIS OF DESIGN. FINAL FLOOR PLANS AND THE

FACILITY FINAL DESIGN REQUIREMENTS (TYPE,

QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE

RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR

AND THE DESIGNER OF RECORD (DOR). CONCEPT

DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;

THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND

COORDINATING FINAL DESIGN REQUIREMENTS WITH

APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,

AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY

CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL

REQUIRE APPROVAL OF THE CONTRACTING OFFICER.

/3

/2

:0

:0

P

M

/1

A-010

J B

L A

N D

C h e c k e r

J B

L A

N D

F E

B R

U A

R Y

P ro j.

N o

A C

E N

T R

A L

H

IL

L A

IR

F

O R

C E

B A

S E

U

T A

H

O V

E R

A L L G

R O

U N

D F

L O

O R

P L A

N

G R

O U

N D

B A

S E

D S

T R

A T

E G

IC

D

E F

E N

S E

SCALE 1/16" = 1'-0"

OVERALL GROUND FLOOR PLAN

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

0 8' 16' 32'

N

GROSS AREA SCHEDULE

AREA SQUARE FOOTAGE

LEVEL 01 53,922 SF

LEVEL 02 42,784 SF

LEVEL 03 40,044 SF

LEVEL 04 39,982 SF

TOTAL 176,731 SFFor Refe ren ce

EXIT ONLY / IDS

CARD READER / X-10 LOCK / KEY PAD

CARD READER

DOOR ACCESS CONTROL

E/I

CX

C

1 3 6 7 8 9 10 11 134 12

A

B

C

D

E

G

F

H

J.1

L

M

N

P

2 5

K

J

7.1

COMM

COMM

COMM

MISSION DEFENSE

OPS CENTER

OFFICE OFFICE

BUILDING SUPPORT

CIRCULATION

HSI LAB

MECH, ELEC, COMM

MISSION DEFENSE CYBER SECURITY

MISSION DEFENSE ENGINEERING

MISSION DEFENSE INTEL GROUP

MISSION DEFENSE NUCLEAR SECURITY

MISSION DEFENSE OPS CENTER

SECURITY

SHARED SPACE

SOFTWARE TEAM ROOM

STAIR 1

STAIR 3

OPEN TO BELOW

OPEN TO BELOW

OPEN TO BELOW

COMM

CONFERENCE

(20-PERSON)

OFFICE

OFFICE

OFFICE COMM

ALARM

OPS FLOOR

SUPPORT

CONFERENCE

(20-PERSON)

MD TDY STATIONS

COMM ELEC

MECH

UNISEX

UNISEX

MOTHER

MEN

ELEC

WOMEN ELEV

MISSION DEFENSE

ENGINEERING

MISSION DEFENSE

CYBER SECURITY

MISSION DEFENSE

NUCLEAR SECURITY

STOR

JAN

STAIR 2

FREIGHT

ELEC

MD OPS TRAINER

OFFICE

CONFERENCE

(30-PERSON)

CONFERENCE

(20-PERSON)

ALARM

VISITOR WORK

SPACE

MD INTELSECURE POST

TRAINER SIM

SUPPORT

MD OPS

CMD OFFICE

CORR

CORR

CONFERENCE

(20-PERSON)

MD INTEGRATION

TEAM

MD ADVERSARY

EMULATION

CX

C

CC

C C

C

C

C

C

C

C

CC

C

C

C

C

C

C COFFICE

CX

CORR

CORR

LOCKERS

C

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

T H

P A

C

IF

IC

D

IV

IS

IO

N

S A

C R

A M

E N

T O

D

IS

T R

IC

T

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

US ARMY CORPS

OF ENGINEERS

SACRAMENTO DISTRICT

P R

O J E

C T

N U

M B

E R

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

2 864 10

E

F

G

F O

R O

F F

IC

IA

L U

S E

O N

L Y

DRAWINGS ARE INTENDED AS A SUPPLEMENT TO

SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL

BASIS OF DESIGN. FINAL FLOOR PLANS AND THE

FACILITY FINAL DESIGN REQUIREMENTS (TYPE,

QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE

RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR

AND THE DESIGNER OF RECORD (DOR). CONCEPT

DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;

THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND

COORDINATING FINAL DESIGN REQUIREMENTS WITH

APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,

AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY

CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL

REQUIRE APPROVAL OF THE CONTRACTING OFFICER.

/3

/2

:0

:3

P

M

/1

A-011

D e s ig n e r

C h e c k e r

A u th o r

F E

B R

U A

R Y

P ro j.

N o

A C

E N

T R

A L

H

IL

L A

IR

F

O R

C E

B A

S E

U

T A

H

O V

E R

A L L S

E C

O N

D F

L O

O R

P L A

N

G R

O U

N D

B A

S E

D S

T R

A T

E G

IC

D

E F

E N

S E

0 8' 16' 32'

N

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SCALE 1/16" = 1'-0"

OVERALL SECOND FLOOR PLAN For Refe ren ce

EXIT ONLY / IDS

CARD READER / X-10 LOCK / KEY PAD

CARD READER

DOOR ACCESS CONTROL

E/I

CX

C

1 3 6 7 8 9 10 11 134 12

A

B

C

D

E

G

F

H

J.1

L

M

N

P

2 5

K

J

7.1

16' - 6" 11' - 6" 16' - 0" 22' - 0" 30' - 0" 22' - 6" 17' - 6" 28' - 0" 26' - 0" 26' - 0" 30' - 0" 30' - 0"

276' - 0"

BUILDING SUPPORT

CIRCULATION

MECH, ELEC, COMM

MULTI-TEAM

RESTROOMS

SECURITY

SHARED SPACE

SMALL TEAM

STAND ALONE ALARMED ROOM

SYSTEM ADMIN / SERVER LAB

MULTI-TEAM

FREIGHT

OUTDOOR

PC BUILD

IT STOR

SERVER

SERVER SUPPORT

SERVER MAINT

ELEC

SERVER MAINT

SERVER

TEST LAB

MULTI-TEAM

SMALL TEAM

SMALL TEAM

SMALL TEAM

ELEC ELEC

SERVER

COMM

ALARM

COMM

SERVER SUPPORT

OFFICE

ALARM OFFICE OFFICE

CONFERENCE

(10-PERSON)

SECURITY POST

STAND ALONE

ALARM ROOM

COMM ELEC

TEST LAB

COMM

OFFICE

COMM

CONFERENCE

(12-PERSON)

CONFERENCE

(8-PERSON)

CONFERENCE

(8-PERSON)

OFFICE

CONFERENCE

(8-PERSON)

CONFERENCE

(8-PERSON)

OFFICE

ELEC STAIR 3

CORR

CORR

MECH

MOTHER

UNISEX

UNISEXELEC

COMM

MEN

WOMEN

ELEV

STOR

JAN

STAIR 1

CX

C C

C

C

C C

C

C

C

C C C

C

C

C

C

C

C

C

C

C

C

C

STAIR 2

ROOF

BELOW

ROOF

BELOW

ROOF

BELOW

LOCKERS

C

CX

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

T H

P A

C

IF

IC

D

IV

IS

IO

N

S A

C R

A M

E N

T O

D

IS

T R

IC

T

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

US ARMY CORPS

OF ENGINEERS

SACRAMENTO DISTRICT

P R

O J E

C T

N U

M B

E R

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

2 864 10

E

F

G

F O

R O

F F

IC

IA

L U

S E

O N

L Y

DRAWINGS ARE INTENDED AS A SUPPLEMENT TO

SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL

BASIS OF DESIGN. FINAL FLOOR PLANS AND THE

FACILITY FINAL DESIGN REQUIREMENTS (TYPE,

QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE

RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR

AND THE DESIGNER OF RECORD (DOR). CONCEPT

DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;

THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND

COORDINATING FINAL DESIGN REQUIREMENTS WITH

APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,

AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY

CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL

REQUIRE APPROVAL OF THE CONTRACTING OFFICER.

/3

/2

:0

:4

P

M

/1

A-012

D e s ig n e r

C h e c k e r

A u th o r

F E

B R

U A

R Y

P ro j.

N o

A C

E N

T R

A L

H

IL

L A

IR

F

O R

C E

B A

S E

U

T A

H

O V

E R

A L L T

H

IR

D F

L O

O R

P L A

N

G R

O U

N D

B A

S E

D S

T R

A T

E G

IC

D

E F

E N

S E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SCALE 1/16" = 1'-0"

OVERALL THIRD FLOOR PLAN

0 8' 16' 32'

NFor Refe ren ce

EXIT ONLY / IDS

CARD READER / X-10 LOCK / KEY PAD

CARD READER

DOOR ACCESS CONTROL

E/I

CX

C 1 3 6 7 8 9 10 114 12

C

D

E

G

F

H

J.1

L

M

N

P

2 5

K

J

7.1

PATIO

BELOW

16' - 6" 11' - 6" 16' - 0" 22' - 0" 30' - 0" 22' - 6" 17' - 6" 28' - 0" 26' - 0" 26' - 0" 30' - 0"

PC BUILD

MULTI-TEAM

CONFERENCE

(10-PERSON)

COMM

ALARM

CORR

BUILDING SUPPORT

CIRCULATION

MECH, ELEC, COMM

MULTI-TEAM

SECURITY

SHARED SPACE

SMALL TEAM

STAND ALONE ALARMED ROOM

SYSTEM ADMIN / SERVER LAB

SERVER MAINT

SERVER

CONFERENCE

(30-PERSON)

ELEC

TEST LAB

OFFICE

SYSTEM ENG

SERVER

ELEC

IT STOR

COMM

SMALL TEAM

SMALL TEAM

SMALL TEAM

OFFICE

COMM

COMM ELEC

STAND ALONE

ALARM ROOM

ALARM OFFICEOFFICE

TEST LAB

SERVER SUPPORT

OFFICE

SERVER SUPPORT

MULTI-TEAM

MECH

STOR

JAN

UNISEX

UNISEX

MEN

WOMENMOTHER

ELEC

CORR

COMM

SECURITY POST

ELEV

CONFERENCE

(8-PERSON)

CONFERENCE

(8-PERSON)

OFFICE

CONFERENCE

(10-PERSON)

CONFERENCE

(8-PERSON)

OFFICE

FREIGHTELEC STAIR 3

CONFERENCE

(12-PERSON)

OFFICE

COMM

STAIR 1

C

C

C

C

C

C

C

C

C

C C

CX

C

C

CC

C

C

C

C

C C

C

C

C

E/I

STAIR 2

C

CX

LOCKERS

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

F

IL

E N

A M

E

S

IZ

E

P L O

T S

C A

L E

IS

S

U E

D A

T E

P R

O J E

C T

N O

C

O N

T R

A C

T N

O

A F

D R

A W

IN

G

C O

D E

X

S O

L

IC

IT

A

T

IO

N N

O

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

U

T H

P A

C

IF

IC

D

IV

IS

IO

N

S A

C R

A M

E N

T O

D

IS

T R

IC

T

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

1 753

A

B

C

D

US ARMY CORPS

OF ENGINEERS

SACRAMENTO DISTRICT

P R

O J E

C T

N U

M B

E R

SHEET ID

N O

T F

O R

C O

N S

T R

U C

T

IO

N

2 864 10

E

F

G

F O

R O

F F

IC

IA

L U

S E

O N

L Y

DRAWINGS ARE INTENDED AS A SUPPLEMENT TO

SECTION 01 10 10, AND PROVIDED AS A CONCEPTUAL

BASIS OF DESIGN. FINAL FLOOR PLANS AND THE

FACILITY FINAL DESIGN REQUIREMENTS (TYPE,

QUANTITY, SIZE, LOCATION, ETC.) ARE THE SOLE

RESPONSIBILITY OF THE DESIGN BUILD CONTRACTOR

AND THE DESIGNER OF RECORD (DOR). CONCEPT

DRAWING INDICATES MINIMUM REQUIREMENTS ONLY;

THE DOR WILL BE RESPONSIBLE FOR VERIFYING AND

COORDINATING FINAL DESIGN REQUIREMENTS WITH

APPLICABLE DOD DESIGN REFERENCE GUIDES, CODES,

AND GOVERNMENT DESIGN TEAM PERSONNEL. ANY

CHANGES TO THE SITE LAYOUT OR FLOOR PLAN WILL

REQUIRE APPROVAL OF THE CONTRACTING OFFICER.

/3

/2

:0

:4

P

M

/1

A-013

D e s ig n e r

C h e c k e r

A u th o r

F E

B R

U A

R Y

P ro j.

N o

A C

E N

T R

A L

H

IL

L A

IR

F

O R

C E

B A

S E

U

T A

H

O V

E R

A L L F

O U

R T

H F

L O

O R

P L A

N

G R

O U

N D

B A

S E

D S

T R

A T

E G

IC

D

E F

E N

S E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SCALE 1/16" = 1'-0"

OVERALL FOURTH FLOOR PLAN

0 8' 16' 32'

NFor Refe ren ce

File details come from the government source that posted it. Updated .