Attachment 4 - ChickenRanchSiding location-layout.pdf
PDF 3 MB Posted
- Attached to
- Chicken Ranch siding replacement
- Solicitation number
- 1240LU26Q0123
- Issued by
-
Department of Agriculture Forest Service
About this file
This document is a figures and images file for the Gardiner Ranger District Chicken Ranch House Siding Replacement project, located in the Custer Gallatin National Forest near Gardiner, Montana.
The project involves comprehensive siding and related exterior work on a residential structure. Key work items include replacing all horizontal lap siding with new wood lap siding or concrete board panel siding, replacing all window trim across four building faces (east, west, north, and south), and installing new windows where indicated. Additional scope includes installing sheet metal flashing above rock/stone foundation elements on multiple faces, installing new ventilation components, removing and reinstalling a satellite dish, painting the underside of the front porch roof (without soffit installation), and performing repairs to wall sheathing as necessary based on investigation findings. The building dimensions are approximately 32 feet 4 inches by 28 feet 7 inches in plan, with varied wall heights ranging from 8 to 16 feet 8 inches. The document provides detailed photographs of existing conditions, including damaged siding, deteriorated soffits and fascia, and close-ups of windows requiring replacement. Design specifications indicate the use of building wrap/air barrier, batt insulation, gypsum board interior finish, and specific flashing and sealant details at door and window openings. All window trim replacements and flashing installations are noted across all four building elevations, with particular emphasis on proper air infiltration barriers and membrane flashing at vulnerable points.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Gardiner Ranger District Chicken Ranch Siding Replacement: Figures/Images
Figure 0: Vicinity Map
Figure 1: East Face Note: Replace all window trim.
Figure 2: West Face Note: Replace all window trim.
WINDOW TO
BE REPLACED
WINDOW TO BE
REPLACED
INSTALL FLASHING
ABOVE ROCK
INSTALL NEW
VENTS
Figure 3: South Face
Figure 4: North Face Note: Replace all window trim.
WINDOW TO
BE REPLACED WINDOW TO
BE REPLACED
INSTALL FLASHING
ABOVE ROCK
REMOVE AND REINSTALL
SATELITE DISH
Figure 5: Front Porch Note: Replace all window trim. Porch roof underside to be painted; no soffit.
Figure 6: Close up of West Face and large window; also note facia condition. Replace all window trim.
INSTALL NEW
VENTS
Figure 7: Photos of existing soffits and facia
Figure 8: Close up of damaged siding. Investigation indicates there is sheathing underneath;
some repairs may be required.
Figure 9: Plan View with dimensions
S
Z. HIEDEMAN
P. FRADY
D. BURNS
TBD
CLINT KOLARICH - DISTRICT RANGER
PARKS FRADY - FOREST ENGINEER
ZAC HIEDEMAN - FACILITY ENGINEER
0 2/10/26 90% DESIGN
DUSTIN BURNS - C.O.R.
RAY DESILVA - FACILITY MANAGER
PROFILE VIEW - SOUTH SIDE OF HOUSE
SCALE: NTS DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO VERIFY.
A
C
B
N
PROFILE VIEW - NORTH SIDE OF HOUSE
SCALE: NTS DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO VERIFY.
D
PROFILE VIEW - WEST SIDE OF HOUSE
SCALE: NTS DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO VERIFY.
PROFILE VIEW - EAST SIDE OF HOUSE
SCALE: NTS DIMENSIONS ARE APPROXIMATE. CONTRACTOR TO VERIFY.
34'-4"
7'
8'
28'-7" 3'-9"
8'
7'
16'-8"
3'-6"
4'-3"
16'-8"
34'-4"
8'
7' 7'
32'-4"
3'-6"
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
RANGER STATION
AutoCAD SHX Text
GARDINER
AutoCAD SHX Text
CUSTER GALLATIN
AutoCAD SHX Text
NATIONAL FOREST
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ISSUE INFORMATION
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AGRICULTURE
AutoCAD SHX Text The Northern Region
AutoCAD SHX Text
FOREST SERVICE
AutoCAD SHX Text
UNITED STATES
AutoCAD SHX Text
DEPARTMENT
AutoCAD SHX Text
J. SNYDER 4-8-87
AutoCAD SHX Text
OF
AutoCAD SHX Text
PROJECT TEAM
AutoCAD SHX Text
CHICKEN RANCH
AutoCAD SHX Text
SHEET OF 2
AutoCAD SHX Text
HOUSE SIDING
AutoCAD SHX Text
GARDINER
AutoCAD SHX Text
AutoCAD SHX Text
PROFILE VIEWS
AutoCAD SHX Text
HOUSE
F
C
TYPICAL WALL CONSTRUCTION
@ LAP SIDING
- WOOD LAP SIDING
- OVER BUILDING WRAP/ AIR BARRIER
- OVER WALL SHEATHING
- OVER WOOD STUDS, U.N.O.
- W/ BATT INSULATION
- W/ GYPSUM BOARD INTERIOR FINISH
UNLESS NOTED OTHERWISE
TYPICAL WALL CONSTRUCTION
@ PANEL & BATT SIDING
- CONCRETE BOARD PANEL & WOOD BATT SIDING
- OVER AIR INFILTRATION BARRIER
- OVER WALL SHEATHING
- OVER WALL FRAMING
- W/ BATT INSULATION
- W/ GYPSUM BOARD INTERIOR FINISH
UNLESS NOTED OTHERWISE
E
D
- OVER FOAM INSULATION
Z. HIEDEMAN
P. FRADY
D. BURNS
TBD
CLINT KOLARICH - DISTRICT RANGER
PARKS FRADY - FOREST ENGINEER
ZAC HIEDEMAN - FACILITY ENGINEER
0 2/10/26 90% DESIGN
DUSTIN BURNS - C.O.R.
RAY DESILVA - FACILITY MANAGER
A
DOOR INSTALLATION PROFILE B
WINDOW INSTALLATION PROFILE C
DOOR HEAD, DETAIL, TYP.
D
WINDOW HEAD, DETAIL, TYP. E
WINDOW SILL, DETAIL, TYP. F
DOOR THRESHOLD, DETAIL, TYP.
HORIZONTAL LAP SIDING
SHEET METAL HEAD FLASHING
2X6 WOOD HEAD TRIM, TYP.
JOINT SEALANT AND
BACKER ROD, TYP.
AIR INFILTRATION BARRIER,
SHOWN DASHED, LAP INTO
OPENING, TYP.
SHIM AS REQUIRED
WINDOW ASSEMBLY,
PER SHEET 7, TYP.
WINDOW ASSEMBLY,
PER SHEET 7, TYP.
4" X 4 HORIZONTAL
WOOD TRIM, TYP.
AIR INFILTRATION
BARRIER, LAP UP
AND OVER SILL
FRAMING, TAPE
WINDOW FLANGES,
TYP.
BATT INSULATION,
TYP.
WALL FRAMING, TYP.
CEMENT BOARD
AND WOOD BAT
SIDING OR
LAP SIDING, TYP.
DOOR ASSEMBLY,
TYP.
EXPANSION JOINT
MATERIAL, TYP.
THRESHOLD
FLOOR SHEATHING
P.T. SILL PLATE
S.S. SHEET METAL
PAN FLASHING, TYP.
EXTEND 6" MIN.
DOWN PAST CONCRETE
HORIZONTAL LAP
SIDING, TYP.
AIR INFILTRATION
BARRIER, LAP INTO
OPENING, TYP.
SHEET METAL
HEAD FLASHING, TYP.
JOINT SEALANT
AND BACKER
ROD, TYP.
SELF-ADHESIVE
MEMBRANE FLASHING,
TYP.
SHIM AS REQUIRED
DOOR ASSEMBLY
TAPE WINDOW FLANGES
W/ SELF-ADHESIVE
MEMBRANE FLASHING, TYP.
2X6 HEAD TRIM,
TYP.
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
RANGER STATION
AutoCAD SHX Text
GARDINER
AutoCAD SHX Text
CUSTER GALLATIN
AutoCAD SHX Text
NATIONAL FOREST
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
ISSUE INFORMATION
AutoCAD SHX Text
PROJECT NO:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
MARK
AutoCAD SHX Text
DATE
AutoCAD SHX Text
AGRICULTURE
AutoCAD SHX Text The Northern Region
AutoCAD SHX Text
FOREST SERVICE
AutoCAD SHX Text
UNITED STATES
AutoCAD SHX Text
DEPARTMENT
AutoCAD SHX Text
J. SNYDER 4-8-87
AutoCAD SHX Text
OF
AutoCAD SHX Text
PROJECT TEAM
AutoCAD SHX Text
CHICKEN RANCH
AutoCAD SHX Text
SHEET OF 2
AutoCAD SHX Text
HOUSE SIDING
AutoCAD SHX Text
AutoCAD SHX Text
WINDOW & DOOR
AutoCAD SHX Text
FLASH / SEAL
AutoCAD SHX Text
DETAILS
| Sheets and Views |
| Gardiner_ChickenRanchSiding_2026-ShopPlanProfile Sheet 5 |
| Gardiner_ChickenRanchSiding_2026-Details Sheet 10 |
File details come from the government source that posted it. Updated .