This document is a Safety Guide for a USSOCOM (United States Special Operations Command) Technical Experimentation Event. The guide outlines the safety requirements and processes for firms demonstrating equipment at the event. Firms are encouraged to submit a Deliberate Risk Assessment (DRA) worksheet, such as DD Form 2977, to identify and mitigate safety risks. Common safety analyses, such as Safety Assessment Reports and Hazard Analyses, are also recommended. The guide provides specific information requirements for systems containing lasers, energetic materials, or radio-frequency/magneto-inductive emitters. Firms are encouraged to integrate system safety into their technology development process and submit relevant safety artifacts beyond the required DRA form. This Safety Guide supports the USSOCOM RFI TE 25-2 Collaborative Autonomy Integration contract opportunity, which seeks solutions for collaborative autonomy integration.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USSOCOM Technical Experimentation Event

Safety Guide

The purpose of this guide is to ensure safety risks associated with the operation of equipment to be demonstrated at a USSOCOM technical experimentation event are identified. Following a rigorous safety process will ensure proper mitigations are identified and implemented facilitating a safe demonstration.

The desired format for submitting a record of safety risks is a Deliberate Risk Assessment (DRA) worksheet. An example is DD Form 2977 which can be found at this link: DD2977. However, the https://sam.gov/ posting should be consulted.

for specific requirements.

Firms developing material for the Department of Defense are encouraged to integrate system safety into the technology development process. Any outputs of this integration will be useful to the team managing the USSOCOM technical experimentation event.

Examples of common safety analyses include: Safety Assessment Reports, System / Subsystem Hazard Analyses, Laser Safety Evaluations, Interim/Final Hazard Classifications, Energetic Material Sensitivity Analyses, Fuse Safety Analyses, and Developmental Test Reports & User Documentation with Warnings/Cautions incorporated.

The typical reference for System Safety within USSOCOM & the Department of Defense is Military-Standard 882, “Standard Practice: System Safety”. The current revision (MIL- STD-882E) is available publicly on the web.

The methodology described in MIL-STD-882E, to include the definitions of probability, severity & risk level, are utilized across all DOD Components & most defense contractors. Consider using these common terms and measures when developing hazard analyses. Submission of safety artifacts beyond the required DD2977 form is highly encouraged, as are efforts to tailor mitigations to the specific technology being demonstrated & the testing scenario.

For reference, the next page lists several areas of frequent concern with the general safety data requirements associated with each area.

If the system contains a laser, the following information should be readily available to the range Laser Systems Safety Officer:

Nominal Ocular Hazard Distance (NOHD) with/without magnification (As applicable) https://va-form.com/ https://beta.sam.gov/ http://www.assistdocs.com/

Optical Density (OD) requirements Design wavelength Beam divergence Output power Any records of a verification of laser output (independent measurement preferred)

If the system contains energetic materials (e.g. propellants, pyrotechnics, explosives), the following information should be made available to the experimentation team:

Record of an Interim Hazard Classification (IHC) Any evaluation of Energetic materials [if novel] (e.g. sensitivity test results) Any evaluation of Fuzing / Safe & Arm / Ignition Safety systems Recommended standoff distances, surface danger zones and/or range fans Summary of any prior live fire testing

If the system contains a Radio-Frequency / Magneto-Inductive (or other) emitter, the following information should be made available to the experimentation team:

Number of frequencies requested and band Transmitter output power Antenna gain Any “Radiation Hazard” (RADHAZ) analyses performed Any established Safe Stand-off Distances (SSDs) for Ordnance, Personnel & fueling operations