Attachment 3 - Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter dated July 26 2024.pdf
PDF 475 KB Posted
- Solicitation number
- MB00525
- Issued by
-
Department of Energy Office of Science
About this file
This document is a Technical Specification for Lead Tungstate (PbWO4) crystals to be used in the Backward Electromagnetic Calorimeter of the Electron-Ion Collider (EIC) detector at Brookhaven National Laboratory.
The specification outlines the technical and performance requirements for the PbWO4 crystals, including physical dimensions, optical properties, radiation tolerance, and environmental, safety, and health requirements. The crystals will be used to precisely measure scattered electrons and photons in Deep Inelastic Scattering experiments at the EIC. The document describes the preproduction testing and acceptance testing that will be performed to ensure the crystals meet the specified requirements. The related federal contract opportunity solicits bids to provide these PbWO4 crystals for the EIC project, with a solicitation number of MB00525 from the Department of Energy Office of Science.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Electron-Ion Collider, Brookhaven National Laboratory
Doc No. EIC-DET-SPC-020 Author: Alexander Bazilevsky Effective Date: July 26, 2024 Review Frequency: N/A
Specification Title: Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter Revision: 01
TECHNICAL SPECIFICATION
for PbWO4 Crystals for the Backward Electromagnetic Calorimeter
Quality Classification: A-3
Prepared By:
_________________________________ Date: __________________ Alexander Bazilevsky, CAM
Tanja Horn, DSL
Reviewed By:
Joseph Zipper, Quality Representative
Marcel Romero, Procurement Liaison Engineer
Chuck Schaefer, ESH Manager
Approved By:
Elke Aschenauer, Level 2 Manager
Docusign Envelope ID: B4329373-B599-4E4E-B96D-ABA70D42A462
7/26/2024
7/26/2024
7/29/2024
7/26/2024
7/26/2024
7/29/2024
Doc No. EIC-DET-SPC-020 Author: Alexander Bazilevsky Effective Date: July 26, 2024 Review Frequency: N/A
Specification Title: Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter Revision: 01
This page intentionally left blank, to accommodate back-to-back printing.
Doc No. EIC-DET-SPC-020 Author: Alexander Bazilevsky Effective Date: July 26, 2024 Review Frequency: N/A
Specification Title: Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter Revision: 01
REVISION HISTORY
Revision # Effective Date Summary of Change
00 1/16/2024 Initial Release
01 7/26/24 Minor revisions to spacing and formatting throughout document.
Doc No. EIC-DET-SPC-020 Author: Alexander Bazilevsky Effective Date: July 26, 2024 Review Frequency: N/A
Specification Title: Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter Revision: 01
TABLE OF CONTENTS
1 BACKGROUND
1.1 Background
2 APPLICABLE DOCUMENTS
3 REQUIREMENTS
3.1 Technical/Performance Characteristics
3.2 Materials
3.3 Environment, Safety and Health
4 VERIFICATION
4.1 Classification of Inspections
Doc No. EIC-DET-SPC-020 Author: Alexander Bazilevsky Effective Date: July 26, 2024 Review Frequency: N/A
Specification Title: Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter Revision: 01
LIST OF ACRONYMS
BNL Brookhaven National Laboratory BSA Brookhaven Science Associates DOE Department Of Energy EIC Electron-Ion Collider ESH Environment, Safety and Health ESR Electron Storage Ring HSR Hadron Storage Ring
PBWO4
RHIC
Lead Tungstate Relativistic Heavy Ion Collider
RCS Rapid Cycling Synchrotron
Doc No. EIC-DET-SPC-020 Author: Alexander Bazilevsky Effective Date: July 26, 2024 Review Frequency: N/A
Specification Title: Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter Revision: 01
Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter
1 BACKGROUND
The Electron-Ion Collider (EIC) is a Nuclear Physics facility being built at the United States (U.S).
Department of Energy’s (DOE) Brookhaven National Laboratory (BNL). The EIC will create intense beams of relativistic energy electrons and ions in opposing particle storage rings that will be brought into collision in a large experimental detector. This will provide insight into the internal structure of protons and neutrons and the gluelike force that holds them together.
1.1 Background
The EIC Project includes one interaction region, with an allowance for a second, and one detector.
The EIC detector is being designed as a hermetic, general-purpose detector. It will be an approximately 10-meter-long cylindrical barrel detector with additional instrumentation that extends to up to 45m in each direction down the EIC beamline. It will use cutting-edge technologies to detect particles created in collisions between high energy electrons and protons or heavy ions (the nuclei of larger atoms) moving close to the speed of light. It will be based on a 1.7 Tesla superconducting magnet for curving the trajectories of charged particles created in these collisions and will include high precision tracking and particle identification systems to measure and identify charged particles, electromagnetic calorimeters to measure and identify electromagnetic particles, and hadronic calorimeters to allow for high precision jet (a collimated spray of particles) measurements.
The Backward Electromagnetic Calorimeter role in the EIC detector is the high precision measurements of scattered electrons to determine the event kinematics in inclusive Deep Inelastic Scattering events, and final state photons. Its design is based on high quality PbWO4 crystals, which convert the energy of the impact electrons and photons into light, subsequently detected by photo sensors.
2 APPLICABLE DOCUMENTS
None.
Doc No. EIC-DET-SPC-020 Author: Alexander Bazilevsky Effective Date: January 16, 2024 Review Frequency: N/A
Specification Title: Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter Revision: 00
3 REQUIREMENTS
3.1 Technical/Performance Characteristics
Parameter Unit Length cm 20 Sides cm 2 Tolerance in Length µm ≤±150 Tolerance in Sides µm ≤±50 Surface polished, roughness Ra µm <0.02 Perpendicularity, parallelism mm ≤0.02 Surface flatness mm ≤0.02 Tolerance in Rectangularity degrees ≤0.1 Emission peak nm 420 Longitudinal Transmission at λ=360nm λ=420nm λ=600nm
>35 >60 >70
Inhomogeneity of Transverse Transmission ∆λ at T=50% nm ≤5
Light Yield at 18degC within gate 100ns pe/MeV >15 Light Yield (100ns)/Light Yield(1 µs) % ≥95 Light Yield uniformity between blocks % 10
Transverse Transmission and Light Yield uniformity along crystal
% 10
Radiation-induced absorption coefficient dk at 18degC for integral dose 30Gy at λ=420nm m-1 ≤1.5
Mean value of dk m-1 ≤0.75
3.2 Materials
Raw material quality shall be commensurate with high quality crystals.
Doc No. EIC-DET-SPC-020 Author: Alexander Bazilevsky Effective Date: January 16, 2024 Review Frequency: N/A
Specification Title: Technical Specification for PbWO4 Crystals for the Backward Electromagnetic Calorimeter Revision: 00
3.3 Environment, Safety and Health
Identification of hazards, and their mitigation, during all stages of the life of the Equipment including; installation, commissioning, operation, maintenance, and repair. Identification of means to eliminate or manage each hazard shall be provided based on the following hierarchy:
• Eliminate the hazard, or
• Substitute with something less hazardous, or
• Engineer – mitigate the severity of the hazard, or
• User Personal Protective Equipment (least desirable).
4 VERIFICATION
Appropriate inspection/tests shall be performed to ensure crystals conform to all requirements in section 3 of this specification.
4.1 Classification of Inspections
Items covered by this specification shall be subjected to the following tests to determine compliance with all applicable requirements:
4.1.1. Preproduction Tests (First Article).
For this purpose, 140 crystals meeting this specification shall be requested by BSA.
4.1.2. Acceptance Tests.
The approval to proceed into production shall be granted based on the results of the tests with first article crystals coordinated by BSA and Detector Subsystem Leader.
| 1 BACKGROUND |
| 1.1 Background |
| 2 APPLICABLE DOCUMENTS |
| 3 REQUIREMENTS |
| 3.1 Technical/Performance Characteristics |
| 3.2 Materials |
| 3.3 Environment, Safety and Health |
| 4 VERIFICATION |
| 4.1 Classification of Inspections |
| 2024-07-29T09:21:44-0700 | |