Attachment 3 Technical Compliance Matrix.docx

DOCX document 36 KB Posted

Attached to
AXION BIOSYSTEMS MAESTRO PRO MICROELECTRODE ARRAY (MEA) SYSTEM – BRAND NAME OR EQUAL
Solicitation number
CBER-2026-135659
Issued by

About this file

This is a Technical Compliance Matrix template that quoters must complete and submit with their quotations for an Axion BioSystems Maestro Pro Microelectrode Array (MEA) System or equal product in response to Solicitation CBER-2026-135659 issued by FDA's Center for Biologics Evaluation and Research (CBER).

The matrix requires contractors to demonstrate compliance across thirteen categories of requirements. Core system requirements include a new, high-throughput, non-invasive, label-free bioelectronic assay platform capable of real-time in vitro electrophysiological measurements with integrated impedance measurement capability, supporting both 2D monolayer and 3D biological models (spheroids and organoids) for neural and cardiomyocyte applications. Recording and stimulation specifications mandate minimum 768 simultaneous channels, 12.5 kHz sampling rate, 0.01 Hz to 5 kHz bandwidth, voltage stimulation up to ±1.2V, and current stimulation up to ±250 microamps. The system must be compatible with multiple MEA plate formats (6-, 24-, 48-, 96-well, and 384-well impedance), including BioCircuit, CytoView, Lumos, and CytoView-Z plates. Environmental controls must include integrated temperature (ambient +7°C to 46°C), CO₂ (0-10%), and humidity control without requiring external incubators. The quotation must include all necessary software (acquisition and analysis modules with neural, impedance, and viability functionality), computer, monitor, consumables, accessories, onsite installation within 30 calendar days, up to two days of onsite training within 60 calendar days, delivery within 90 calendar days, standard one-year manufacturer warranty, and an optional one-year performance assurance/preventive maintenance service package. For each requirement, quoters must state compliance status, describe specific proposed specifications, cite supporting documentation, and identify any deviations, with incomplete responses subject to rejection as technically unacceptable.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 3

SIDE-BY-SIDE TECHNICAL COMPLIANCE MATRIX

Axion BioSystems Maestro Pro Microelectrode Array (MEA) System – Brand Name or Equal Solicitation Number: ______________________________ Quoter/Contractor Name: ______________________________ Manufacturer: ______________________________ Proposed Product/Model: ______________________________ Manufacturer Part Number: ______________________________

UEI: ______________________________

INSTRUCTIONS TO QUOTERS

The quoter shall complete this matrix and submit it with its quotation.

For each requirement, the quoter shall:

1. State whether the proposed product Complies with the Government requirement;

1. Describe the specific feature, capability, or specification of the proposed product;

1. Identify the page, section, URL, technical data sheet, manual, or other supporting documentation where the Government can verify the information; and

1. Identify and explain any deviation from the stated requirement.

A response consisting solely of “Complies,” “Yes,” “Meets Requirement,” or similar wording without supporting technical information may be considered insufficient.

For a product offered as brand name or equal, the Government will use this matrix and supporting documentation to determine whether the proposed product meets all required salient characteristics.

Failure to demonstrate compliance with a material requirement may result in a rating of Technically Unacceptable.

A. SYSTEM AND GENERAL REQUIREMENTS

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Specification / Response
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
A1
Equipment Condition
One new Microelectrode Array system. Equipment shall be new and complete.
A2
Brand Name or Equal
Axion BioSystems Maestro Pro MEA System, or equal.
A3
System Type
High-throughput, non-invasive, label-free bioelectronic assay platform.
A4
Electrophysiology
System shall provide real-time in-vitro electrophysiological measurement.
A5
Impedance Measurement
System shall provide integrated impedance measurement capability.
A6
2D Cell Culture Compatibility
System shall support 2D monolayer cell cultures.
A7
3D Model Compatibility
System shall support 3D biological models, including spheroids and organoids.
A8
Neural Cell Applications
System shall support applications involving neurons, including iPSC-derived neurons.
A9
Cardiomyocyte Applications
System shall support applications involving cardiomyocytes.
A10
Complete Operational System
Quotation shall include all components, accessories, hardware, software, licenses, and other items required for a complete operational system.

B. RECORDING AND STIMULATION CAPABILITIES

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Specification / Response
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
B1
Simultaneous Channels
Minimum 768 simultaneous recording and stimulation channels.
B2
Sampling Rate
Minimum sampling rate of 12.5 kHz.
B3
Bandwidth
Required bandwidth approximately 0.01 Hz – 5 kHz.
B4
Voltage Stimulation
Stimulation capability up to approximately +/-1.2 V.
B5
Current Stimulation
Stimulation capability up to approximately +/-250 microamps.
B6
Multi-Channel Stimulation
Stimulation capability shall be available across all required channels.
B7
Recording Technology
Technology shall provide performance functionally equivalent to Axion BioCore v4 chip technology.

C. IMPEDANCE MEASUREMENT

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Specification / Response
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
C1
Electrode Impedance Dynamic Range
Approximately 50 ohms – 5 kohms.
C2
MEA Viability Dynamic Range
Approximately 5 kohms – 100 kohms.
C3
Automatic Monitoring
System shall provide automatic integrated impedance monitoring.
C4
Real-Time Monitoring
Impedance monitoring shall be available in real time.
C5
Viability Measurement
System shall support MEA viability measurements.

D. PLATE COMPATIBILITY

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Specification / Response
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
D1
6-Well MEA
Compatible with 6-well MEA format.
D2
24-Well MEA
Compatible with 24-well MEA format.
D3
48-Well MEA
Compatible with 48-well MEA format.
D4
96-Well MEA
Compatible with 96-well MEA format.
D5
384-Well Impedance
Impedance measurement capability up to 384-well format.
D6
BioCircuit MEA Compatibility
Compatible with BioCircuit MEA plates or functionally equivalent plate technology.
D7
CytoView MEA Compatibility
Compatible with CytoView MEA plates or functionally equivalent technology.
D8
Lumos MEA Compatibility
Compatible with Lumos MEA plates or functionally equivalent technology.
D9
CytoView-Z Compatibility
Compatible with CytoView-Z or functionally equivalent technology.
D10
3D MEA Applications
Supports required 3D MEA plate/application capability.

E. ENVIRONMENTAL CONTROL

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Specification / Response
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
E1
Integrated Environmental Chamber
System shall contain integrated environmental control.
E2
Temperature Control
Approximately ambient +7 degrees C through 46 degrees C.
E3
CO2 Control
Approximately 0–10% CO2 control range.
E4
Humidity Control
Integrated humidity control.
E5
External Incubator
System shall support experimentation without requiring an external incubator during data acquisition.

F. PHYSICAL AND ELECTRICAL REQUIREMENTS

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Specification / Response
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
F1
Physical Footprint
Proposed system shall be suitable for laboratory installation. Reference system dimensions: approximately 280 x 452 x 225 mm (W x D x H).
F2
System Weight
Reference system weight approximately 30.6 lbs / 13.9 kg. Identify proposed system weight.
F3
Electrical Power
Compatible with approximately 100–240 V AC, 50–60 Hz laboratory power.
F4
Power Requirement
Identify amperage and any special electrical requirements.

G. SOFTWARE REQUIREMENTS

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Specification / Response
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
G1
Integrated Acquisition Software
Integrated software for data acquisition.
G2
Real-Time Visualization
Software shall provide real-time data visualization.
G3
Data Analysis
Software shall provide data analysis capabilities.
G4
Neural Module
Neural electrophysiology analysis module or equivalent.
G5
Impedance Module
Impedance analysis functionality.
G6
MEA Viability Module
MEA viability functionality or equivalent.
G7
Automation
System shall provide automation capability.
G8
API Capability
Identify supported automation/API capability. Reference system supports C#, Python, and MATLAB integration.
G9
AxIS Navigator
AxIS Navigator or functionally equivalent acquisition/navigation software.
G10
AxIS Analysis
AxIS Analysis or functionally equivalent analysis software.
G11
Software Licenses
All software licenses required to operate the system shall be included.
G12
Analysis Seats
Minimum two analysis-software seats/licenses.
G13
License Type
Identify whether licenses are perpetual, subscription, node-locked, floating, or other.
G14
License Term
Identify duration of each software license.
G15
Software Updates
Describe included software updates/upgrades during warranty period.

H. COMPUTER AND MONITOR

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Specification / Response
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
H1
Computer
Contractor shall provide the computer required to operate the system.
H2
Monitor
Contractor shall provide required monitor/display.
H3
System Compatibility
Computer shall meet or exceed manufacturer’s recommended specifications for all included software and hardware.
H4
Operating System
Identify operating system and version.
H5
Processor
Identify processor specification.
H6
Memory
Identify installed RAM.
H7
Storage
Identify storage capacity and configuration.

I. CONSUMABLES AND ACCESSORIES

No.
Government Requirement / Salient Characteristic
Minimum Government Requirement
Contractor Proposed Product / Quantity
Supporting Documentation / Page Reference
Complies? Yes/No
Contractor Comments / Explanation
I1
CytoView MEA 48-Well Plates
Provide required 48-well MEA plates or equal.
I2
CytoView MEA 96-Well Plates
Provide required 96-well MEA plates or equal.
I3
3DMap MEA Plates
Provide required 3DMap MEA plates or equal.
I4
MEA Creator Kit
Provide MEA Creator Kit or equal.
I5
Required Accessories
Include all cables, connectors, adapters, and accessories required for full operation.
I6
Additional Consumables
Identify all additional consumables included in the quotation.

J. INSTALLATION AND SYSTEM VALIDATION

No.
Government Requirement
Minimum Government Requirement
Contractor Proposed Approach / Response
Supporting Documentation / Reference
Complies? Yes/No
Contractor Comments / Explanation
J1
Onsite Installation
Contractor shall provide onsite installation at FDA/CBER, Silver Spring, Maryland.
J2
Hardware Setup
Contractor shall install and configure all hardware.
J3
Software Installation
Contractor shall install all required software.
J4
Software Activation
Contractor shall activate all required software licenses.
J5
Calibration
Contractor shall perform required system calibration.
J6
Performance Verification
Contractor shall verify system performance to manufacturer specifications.
J7
Validation Documentation
Contractor shall provide written installation/system-validation confirmation.
J8
Installation Schedule
Installation/validation shall be completed within 30 calendar days after equipment delivery.

K. TRAINING

No.
Government Requirement
Minimum Government Requirement
Contractor Proposed Approach / Response
Supporting Documentation / Reference
Complies? Yes/No
Contractor Comments / Explanation
K1
Onsite Training
Provide onsite user training at FDA/CBER.
K2
Duration
Up to two days of onsite training.
K3
Hardware Operation
Training shall cover hardware operation.
K4
Acquisition Software
Training shall cover AxIS Navigator or equivalent.
K5
Analysis Software
Training shall cover AxIS Analysis or equivalent.
K6
Neural Applications
Training shall address neural electrophysiology applications.
K7
Organoid Applications
Training shall address neural organoid MEA applications.
K8
Training Documentation
Contractor shall provide attendance or completion documentation.
K9
Training Schedule
Training shall be completed within 60 calendar days after equipment delivery.

L. DELIVERY

No.
Government Requirement
Minimum Government Requirement
Contractor Proposed Response
Supporting Documentation / Reference
Complies? Yes/No
Contractor Comments / Explanation
L1
Delivery Schedule
Equipment delivery within 90 calendar days after award.
L2
FOB
FOB Destination.
L3
Delivery Location
FDA/CBER, Building 52/72, Room 3148, 10903 New Hampshire Avenue, Silver Spring, MD 20993.
L4
Delivery Coordination
Contractor shall coordinate delivery with COR at least five business days in advance.
L5
Complete Delivery
All equipment and required components shall be delivered complete and undamaged.
L6
Packing List
Contractor shall provide a complete packing list.

M. WARRANTY

No.
Government Requirement
Minimum Government Requirement
Contractor Proposed Warranty
Supporting Documentation / Reference
Complies? Yes/No
Contractor Comments / Explanation
M1
Warranty Period
Standard manufacturer one-year warranty.
M2
Hardware Defects
Warranty shall cover hardware defects in design, workmanship, and materials.
M3
Parts Coverage
Identify parts coverage.
M4
Labor Coverage
Identify labor coverage.
M5
Warranty Start
Identify proposed warranty commencement date/event.
M6
Warranty Service
Describe procedure for requesting warranty service.
M7
Technical Support
Identify technical support available during warranty period.

N. OPTION YEAR 1 – PERFORMANCE ASSURANCE / PREVENTIVE MAINTENANCE

No.
Government Requirement
Minimum Government Requirement
Contractor Proposed Service
Supporting Documentation / Reference
Complies? Yes/No
Contractor Comments / Explanation
N1
Maintenance Plan
PASPM768PRO-OS onsite performance assurance/preventive maintenance service or equal.
N2
Option Duration
12 months.
N3
Commencement
Option period commences following expiration of standard manufacturer warranty.
N4
Onsite PM Visit
Minimum one onsite preventive maintenance visit during option period.
N5
Parts
Required parts included.
N6
Labor
Required labor included.
N7
System Verification
Contractor shall verify system operation following maintenance.
N8
Service Report
Written service report required after onsite preventive maintenance visit.
N9
Report Contents
Report shall identify services performed, parts replaced, if any, and system status.
N10
Report Due Date
Service report within 10 business days after onsite visit.

O. CONTRACTOR TECHNICAL CERTIFICATION

The undersigned certifies that:

1. The information provided in this matrix is complete and accurate;

1. The proposed equipment and services comply with the requirements identified as “Yes”;

1. Any exceptions or deviations have been fully disclosed;

1. Supporting documentation submitted with the quotation accurately describes the equipment proposed;

1. Country-of-origin and place-of-manufacture information is accurate to the best of the quoter’s knowledge; and

1. The quoter understands that the Government may rely upon this information in determining technical acceptability and eligibility for award.

Company Name: __________________________________________ Authorized Representative: __________________________________________ Title: __________________________________________ Signature: __________________________________________ Date: __________________________________________ Telephone: __________________________________________ Email: __________________________________________