Attachment 3 - SOW Attch 02 - AS003_ Site Plan.pdf
PDF 792 KB Posted
- Solicitation number
- 36C77625R0049
About this file
The document is a future architectural site plan for the Tucson CMOP (Central Mail Out Pharmacy) Building located at 3675 E. Britannia Dr. in Tucson, Arizona. The site plan details comprehensive physical security measures, including multiple gate systems with advanced security features such as electric strikes, dual-authentication PIV & PIN code access control systems, auto-closers, contact sensors with anti-prop alarms, and fixed facial analytics cameras tied to the VA employee database. The plan includes various gate types (pedestrian, sliding, and vehicle gates), anti-ram barriers meeting ASTM F2656 standards, and provisions for future building expansion, with precise measurements and detailed placement of security infrastructure across the site.
The site plan specifically outlines security elements like 30', 40', and 50' sliding gates, gate control islands, retractable anti-ram systems, and secure fence connections between new and existing perimeters. The design incorporates multiple entry and exit points for different functions (employee, delivery, logistics) with controlled access and one-way traffic flow. The drawing is marked as "Issued for Construction" on 03/14/2022, with subsequent addendums in 05/20/2022 and 06/19/2023, and is part of the VA Health Care System's project with drawing number AS003 and project number 762-301.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. ARM EACH EXISTING AND FUTURE PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH
COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT
SENSOR WITH ANTI-PROP ALARM, AND FIXED FACIAL ANALYTICS CAMERA, ALL MONITORED BY
THE SCC AND A LOCALIZED STATION WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP
MANAGER). ENSURE THE FACIAL ANALYTICS CAMERAS ARE TIED TO THE VA EMPLOYEE
DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE CREDENTIAL USAGE
OR TAILGATING. REFER ELECTRICAL.
2. INSTALL PEDESTRIAN GATES AT EACH VEHICLE GATE, ENSURING THE PEDESTRIAN GATES
ARE CONSTRUCTED OF THE SAME MATERIAL AS THE FENCE SYSTEM, AND ARMED AS
DETAILED IN ITEM 1 ABOVE. ARM EACH PEDESTRIAN GATE WITH AN ELECTRIC STRIKE (WITH
COVER PLATE), DUAL-AUTHENTICATION PIV & PIN CODE PACS, AUTO-CLOSER, AND CONTACT
SENSOR WITH ANTI-PROP ALARM, ALL MONITORED BY THE SCC AND A LOCALIZED STATION
WITHIN THE CMOP (I.E., ADMINISTRATION DESK OR CMOP MANAGER). ADDITIONALLY, ENSURE
A FIXED FACIAL ANALYTICS CAMERA IS INSTALLED AT THE GATE ENTRY, TIED TO THE VA
EMPLOYEE DATABASE FOR CONFIRMATION, AS TO PREVENT UNAUTHORIZED/FORCE
CREDENTIAL USAGE OR TAILGATING. REFER ELECTRICAL.
3. BOLLARD SPACING IS 4" O.C. TYP.
GENERAL PLAN NOTES
EXISTING LANDSCAPED AREA
PAVED AREA
EXISTING BUILDING
NEW LANDSCAPED AREA
FUTURE BUILDING
EXISTING FENCING
NEW FENCING
LIGHT FIXTURE REF. ELECTRICAL
E BRITANNIA DR
E H
E M
IS
P
H E
R E
L O
O P
DELIVERY/
LOGISTIC EXIT
E DESERT WALK LN
CMOP
DELIVERY
EXIT
DELIVERY/
LOGISTIC
ENTRY
EMPLOYEE
ENTRY / EXIT
EMPLOYEE
ENTRY / EXIT
ONE WAY EXIT ONLY
ONE
WAY
TRAFFIC
ONE WAY EXIT ONLY
'-4
'-0
1'
-6
F V
2.08 32.09
2.082.12
32.03 32.02
32.04
32.03 32.02
32.07
32.05
32.03 32.06
32.02
32.08
2.13
32.12
2.08
32.02
32.07
2.12
2.15
32.11
2.12
2.16
2.17
2.18 32.1132.1132.11
32.07
26.04
FUTURE BLDG
STORAGE / ADMIN
DELIVERY
ENTRY
9'
-2
107'-4"
92'-0" 89'-4"
21 21 21 21
81010
910 10
'-0
7'-0" 20'-0" 1'-6" 32'-0"
'-0
'-1
'-1
1"
'-1 0"
'-8
6' -1
0"
'-0
113'-6"68'-5" 99'-7" 7'-5" 84'-7"
5'
-2
F V
85'-0" 85'-0" 85'-0" 57'-7"
357'-0"
'-1
0"
'-0
'-0
3'
-4
9"4'-0"
32.06
32.03 32.13
4'-0" 4'-6"
'-1
0"
32.12
32.13
370'-0" FV
32.13
26.04
26.04
26.04
26.04
26.04
26.04
32.02
32.02
32.05
32.14
32.14
32.14
32.14
32.14
32.14
32.15
32.15
32.15
32.15
32.15
32.15
32.15 32.15 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
CERTIFICATE OF AUTHORITY NO. 20013-0
EXP. 09/30/2022
CIVIL ENGINEER
H2B, INC.
1225 NORTH LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/1
/2
:5 :1
P
M
FUTURE ARCHITECTURAL SITE PLAN
ECO 19 36DRH
ISSUED FOR CONSTRUCTION
TUCSON CMOP BUILDING
ACQUISITION MINOR
03/14/2022
762-301
VA CMOP
3675 E. BRITANNIA DR.
TUCSON, ARIZONA, 85706
AS003
SPUR #: 2091.02
N
SITE PLAN LEGEND
1" = 50'-0"
FUTURE SITE PLAN1
KEYNOTE LEGEND
2.08 EXISTING FENCE TO REMAIN
2.12 EXISTING MAN GATE TO REMAIN
2.13 EXISTING LIGHTING PEDESTAL TO REMAIN
2.15 EXISTING HVAC UNITS TO REMAIN
2.16 EXISTING CONEX / HVAC EQUIP. TO REMAIN
2.17 EXISTING UPS TO REMAIN
2.18 EXISTING GENERATOR TO REMAIN
26.04 FUTURE LIGHT FIXTURE, TYP. REF. ELECTRICAL. OUT OF SCOPE
32.02 NEW FENCE TO MATCH EXISTING
32.03 GATE CONTROL ISLAND
32.04 ANTI-RAM BARRIERS ASTM F2656 M10
32.05 RETRACTABLE ANTI-RAM SYSTEM ASTM F2656 M30
32.06 NEW PEDESTRIAN GATE
32.07 30' SLIDING GATE AND TRACK
32.08 40' SLIDING GATE AND TRACK
32.09 50' SLIDING GATE AND TRACK
32.11 ANTI-RAM BARRIERS ASTM F2656 M30
32.12 FUTURE SLIDING GATE AND TRACK, OUT OF SCOPE
32.13 FUTURE FENCE TO MATCH EXISTING, OUT OF SCOPE
32.14 GATE OPERATOR. LOCATION TO BE COORDINATED ON FIELD. REF. SPEC FOR CONCRETE
PAD, IF NEEDED.
32.15 PROVIDE SECURE CONNECTION BETWEEN NEW AND EXISTING FENCE AT THIS LOCATION
FOR REFERENCE ONLY
No. REVISION DESCRIPTION DATE
1 ADDENDUM 01 05/20/2022
3 ADDENDUM 03 06/19/2023
File details come from the government source that posted it. Updated .