Attachment 3 JNB-W8_Architectural Drawings.pdf
PDF 14 MB Posted
- Attached to
- RFP for a Construction project at a Government-owned property in Johannesburg, South Africa
- Solicitation number
- 19SF5026P0036
- Issued by
-
Department of State US Embassy Pretoria
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 19SF5026R0036.pdf | ||
| SF30-AMENDMEND TO 19SF5026R0036.pdf | ||
| 19SF5026R0036.pdf | ||
| Attachment 4 JNB-W8_ Structural Drawings.pdf | ||
| Attachment 5 JNB-W8_Electrical Drawings.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SAJ ARCHITECTSCC
8 SAINT SEBASTIAN DRIVE, WENDYWOOD, SANDTON, JOHANNESBURGP O BOX 18570, ACTONVILLE, 1506
TEL : 011 802 0854 FAX : 086 600 4896 CELL: 083 560 4986
E-MAIL : SUNDEEPJ@SAJARC.COM
ARCHITECTURAL DRAWINGS
SITE: 7 TREBYAM AVENUE, EDENBURG, SANDTON, JOHANNESBURG,2128. U.S.
CONSULATE GENERAL JOHANNESBURG, SOUTH AFRICA
mailto:sundeepj@sajarc.com mailto:sundeepj@sajarc.com
INDEX
Plans
1. 100 - Ground Floor Plan Demolition Layout
2. 101 - Ground Floor Plan Proposed New Layout
3. 102 - Wheelchair Maneuver Clearance
4. 103 - Overall Site Plan, Plan, Sections & Elevations
5. 104 - Site Plan, Section & Proposed Pool Fence
Details
5. 400 - Joinery Layout
6. 401 - Handrail Detail
7. 402 - ClearVu Fence Specifications
Schedules
8. 500 - Ground Floor Plan with Door & Window Tags
9. 501 - Door Schedule 001
10.503 - Door Schedule 002
11.504 - Door Schedule 003
12.505 - Window Schedule 001
13.506 - Sanitary Schedule
14.507 - Finishing Schedule
Room Data Sheets
15. 600 - Kitchen-Demolition Elevations
16. 601- Kitchen-Demolition Plan, Proposed New Plan & Sink Clearance Section
17. 602 - Kitchen-Proposed Elevations
18. 603 - Kitchen-Proposed Tiling and Ceiling Plans
19. 604 - Scullery- Demolition Plan & Elevations
20. 605 - Scullery-Proposed New Plan & Elevations
21. 606 - Bathroom 1-Demolition Plans & Elevations
22. 607 - Bathroom 1-Proposed New Plans & Elevations
23. 608 - Bathroom 1-Proposed Tiling & Ceiling Plans
24. 609 - Courtyard-Demolition Layout
25. 610 - Courtyard-Proposed New layout
Drawings
7.
Exist.
Family Room
4.
Exist.
Breakfast Room
3.
Exist.
Dining Room
5.
Exist. Kitchen
1.
Exist.
Lobby
10.
Exist.
Bathroom2
. E xi st
. P as sa ge
9.
Bathroom1
19.
Exist.
Bathroom3
18.
Exist.
Bedroom2 / playroom
8.
Exist.
Bedroom 1
12.
Exist.
Passage 3
12.
Exist.
Passage 2
13. Exist. Passage 1
14.
Exist.
Bedroom 4
17.
Exist.
Bathroom5
15.
Exist.
Bedroom 3
16.
Exist.
Bathroom4
BIC
BIC
21.
Exist.
Storeroom 1
23.
Exist.
Staffroom 2
22.
Exist.
Staffroom 4 24.
Exist.
Utility Room
25.
Exist.
Staffroom 1
Exist.
Gas
Cylinder Area
20.
Exist Courtyard Refer to Room
Data Sheet
-1871
-1871
-1535
-165
BIC
2.
Exist.
Lounge
FFL +00
FFL -296
FFL -375
BIC
BIC
BIC
BIC
BICLine of existing beam overhead
6.
Exist.
Scullery UP
C hi m ne y to b e br ic ke d up to m at ch th e ex is tin g w al l m at er ia l a nd fi ni sh
C hi m ne y to b e br ic ke d up to m at ch th e ex is tin g w al l m at er ia l a nd fi ni sh
Existing retaining wall
EXIST.
Lawn
Drivew ay
EXIST.
Grass/Lawn
EXIST.
Lawn
EXIST.
Grass/Lawn
EXIST.
Grass/Lawn
EXIST.
Grass/Lawn
A A
B
B
26.
Existing Parking
Existing ramp
D B
DB
EXIST.
Pavement
Existing covered patio
-165
EXIST.
Concrete Stair
UP
3m Building Line
3m Building Line
D em ol is h w al l
EXIST. Precast Wall
Existing Door to be removed and replaced
Existing Roof Line
Existing Roof Line
Ex is tin g
R oo f L in e
Ex is tin g
R oo f L in e Ex is tin g R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Exis tin g R oo f L ine
Ex is tin g
R oo f L in e
-1535
EXIST.
Concrete Stair
Exist.
Storeroom 2
EXIST.
Pavem ent
Existing retaining w all
Existing Storm water drain pipe
Existing Drain Channel
G
Existing drainage to municipal connection Existing Storm water drain pipe
Existing Storm water drain pipe
G
Ex is tin g
R oo f L in e
Existing tiles to be removed
Existing sink to removed and placed on opposite wall.
Existing Carpet to be removed and replaced with Luxury Vinyl Tile with self-leveling screed.
New Tile
Existing Carpet to be removed and replaced with Luxury Vinyl Tile with self-leveling screed.
Existing Carpet to be removed and replaced with Luxury Vinyl Tile with self-leveling screed.
Existing Carpet to be removed and replaced with Luxury Vinyl Tile with self-leveling screed.
Existing Door to be removed and replaced with window
Existing Door to be removed and replaced with new door and window
Existing door to be removed and replaced with new door and window
Existing door and door frame to be removed and replaced with window
Existing trees and hedges to be removed
Bath
BIC
Shower
Existing door and door frame to be removed Existing window and window frame to be demolished
D ou bl e do or be re m ov ed
Existing Island table to be removed
Demolish wall to increase opening to
1240mm
Portion of floor to be demolished
Portion of wall to be demolished as per door and window schedule for new door and window
Existing BIC to be demolished
Paving to be rem oved
Paving to be removed
Ex is tin g st ai rs to b e de m ol is he d
St ai rs to b e de m ol is he d
Existing drainage pipes along wall to be removed
Existing door and door frame to be removed
Existing fountain to be demolished and removed
966672
EXIST. Paved Walkway
Existing BIC to be removed
Existing door to be removed
All existing bathroom fixtures to be demolished and removed
Existing tiles to be removed
Existing tiles to be removed Existing tiles to be removed
Existing tiles to be removed
Existing door to be removed and opening to be increased to 930mm
Ex is tin g cu pb oa rd s an d ca bi ne ts to b e re m ov ed
Existing Roof Line
Ex is tin g
R oo f L in e
Ex is tin g
R oo f L in e
Storeroom to be lifted 174mm from Level -174 to +0
Wall to be demolished
Mesh grating to be placed over exposed stormwater pipe
Existing rubble to be rem oved, area to be filled along w ith new grass.
Walls to be demolished
Existing service pipes to be protected, electrical cables to be used for boundary wall, carport + ramp lighting
Existing gate to be removed
Walls to be demolished
To be repaved Pa vi ng to b e re m ov ed
Existing down pipe to be shifted to allow for new wall
Ex is tin g ga s cy lin de r co nc re te p lin th to b e de m ol is he d an d re m ov ed
Existing Conc. Stairs
Sliding door to be removed
GROUND FLOOR PLAN DEMOLITION LAYOUT
Scale 1:75
GENERAL NOTES
1.All materials and workmanship are to comply with the relevant S.A.B.S codes 2.This drawing is not to be scaled. Figured dimensions to be used. All dimensions are in millimetres unless otherwise stated
3. This drawing must be read in conjunction with all the relevant drawings and specifications
4. Any discrepancies on the drawing are to be brought to the architect's attention by the contractor before putting work in hand
5. All dimensions and levels must be checked on site by the contractor before putting work
6. The contractor must obtain the Architect's written confirmation of any instruction which involve a variation to the contract before putting work in hand
7. All voids, suspended ceilings and partitions to be rodent proof in accordance with the government rodent proofing regulations
8. All mechanical and electrical work is to be done in accordance with the National Building Regulations
9. The contractor is to locate and identify any/all existing services and to protect these from damage whilst on site throughout the construction period
DRAINAGE NOTES
1. Access eyes to all bends and junctions and changes in gradient to waste and soil pipes.
2. All rodding eyes to have marked covers at ground level.
3. All waste pipes to be fully accessible.
4. Waste fittings to have 75mm deep seal traps.
5. Gradients to waste branches to be between 1,25 and 5.
6. Gradients to soil branches to be between 2,5 and 45.
7. All soil pipes under building to be encased in min 150mm concrete.
PROJECT : Design and Construction documentation of Accessibility upgrade 7 TREBYAM AVENUE, EDENBURG SANDTON
CLIENT: DRAWING NAME:
DRAWING FOR:DATE:
DRAWN BY:
Rebaone Molokwane
CHECKED BY:
Sundeep Jivan
SITE:
SCALE:
As per drawing
JOB NO: DRAWING NO: REVISION:
REV Date Description Dwn by: Ckd by:
COPYRIGHTS. THE DESIGN AND DRAWINGS REMAIN THE INTELLECTUAL PROPERTY RIGHTS OF
SAJ ARCHITECTS. THIS DOCUMENT MAY ONLY BE REPRODUCED WITH WRITTEN PERMISSION
OF SAJ ARCHITECTS. ALL RIGHTS RESERVED
SAJ ARCHITECTS
8 SAINT SEBASTIAN DRIVE
WENDYWOOD, SANDTON
CELL: 083560 4986
sundeepj@sajarc.com sajsundeep@gmail.com
SHEET NO:
01 December 2025
7 Trebyam Avenue, Edenburg, Sandton, Johannesburg, 2128.
U.S. Consulate General Johannesburg, South Africa
Issue for Construction
D
ES
IG
N
IS
SU
E
FO
R C
O N
ST
R
U C
TI
O
N Unclassified (U)
This document is the property of the U.S. Government.
Further reproduction and distribution are prohibited without the express written approval of U.S. Department of State, Consulate General Johannesburg, 1 Sandton Drive, Sandhurst, Johannesburg, 2146, South Africa.
00 01 Dec 2025 R. Molokwane S.Jivan
WARNING
1. Ground Floor Plan Demolition Layout
Family Room
4, Exist.
Breakfast Room
3.
Exist.
Dining Room
5.
Exist. Kitchen
1.
Exist.
Lobby
10.
Exist.
Bathroom2
. E xi st
. P as sa ge
9.
Bathroom1
19.
Exist.
Bathroom3
18.
Exist.
Bedroom 2
8.
Exist.
Bedroom 1
12.
Exist. Passage 3
12.
Exist.
Passage 2
13. Exist. Passage 1
14.
Exist.
Bedroom 4
17.
Exist.
Bathroom5
15.
Exist.
Bedroom 3
16.
Exist.
Bathroom4
BIC
BIC
21.
Exist.
Storeroom 1
23.
Exist.
Staffroom 2
22.
Exist.
Staffroom 4 24.
Exist.
Utility Room
25.
Exist.
Staffroom 1
Exist.
Gas
Cylinder Area
20.
Exist Courtyard Refer to Room
Data Sheet
-1871
-1871
-1535
-165
BIC
2.
Exist.
Lounge
FFL +00
FFL -296
FFL -375
BIC
BIC
BIC
BIC
BICLine of existing beam overhead
6.
Exist.
Scullery
D
N ew
:1
R am p
1:12 Ramp
UP
Storeroom to be lifted 174mm from Level -174 to +0
New Slab
1:12 Ramp
1:12 Ramp
New Bath Non ADA
WHB
New Toilet
N ew
S ho w er ø1525
Chimney to be bricked up to match the existing wall material and finish
Chimney to be bricked up to match the existing wall material and finish
New 165 mm thick concrete slab to match entrance slab
1:12 Ramp12
1388 700
Existing retaining wall
EXIST.
Planting
Drivew ay
EXIST.
Grass/Lawn
EXIST.
Planting
EXIST.
Grass/Lawn
EXIST.
Grass/Lawn
EXIST.
Grass/Lawn
A A
B
B
Access aisles
26.
Existing Parking
Existing ramp
D B
DB
EXIST.
Pavement
-174
Existing covered patio
-165
EXIST.
Concrete Stair
UP
3m Building Line
3m Building Line
EXIST. Precast Wall
Install custom size single HPT door.
Existing Roof Line
Existing Roof Line
Ex is tin g
R oo f L in e
Ex is tin g
R oo f L in e Ex is tin g R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Exis tin g R oo f L ine
Ex is tin g
R oo f L in e -1535
-187
C on cr et e st ai r
0m m ri se r
0m m tr ea d
-13
New walkway - Max 1:20 slope
New 1:12 Ramp
New ramp
Landing
EXIST.
Concrete Stair
Exist.
Storeroom 2
EXIST.
Pavem ent
Existing retaining w all to be replasted
Existing Storm water drain pipe
Existing Drain Channel
Existing drainage to municipal connection G
Existing drainage to municipal connection Existing Storm water drain pipe
Existing Storm water drain pipe
G
Ex is tin g dr ai na ge un ic ip al c on ne ct io n Ex is tin g R oo f L in e
All switches to be moved to 1200mm from FFL to centerline of plug point.
All low plug points to be moved to 400mm from FFL to centerline of plug point.
New Tile
New Tile
New Tile
New Tile
New Tile, self-leveling screed from fireplace level to line up with lobby level.
UP
2086 4883
N ew w alkw ay - M ax 1:20 slope
N ew w al kw ay
M ax
:2 sl op e
New walkway - Max
1:20 slope
NEW.
Grass/Lawn
1825 600 1710
-593 -469
-339
-764
-902
610 5510
New Proposed drainage pipes to be placed on opposite South facing wall
N ew
D oo r
New Luxury Vinyl Tile with self-leveling screed.
New Tile
New Luxury Vinyl Tile with self-leveling screed.
New Luxury Vinyl Tile with self-leveling screed.
625 300 300
New Luxury Vinyl Tile with self-leveling screed.
Ramp to be made good again with plaster
Install standard single HPT door. Remaining space to be bricked up, plastered and painted.
New Window to match, bottom part to be bricked up, plastered and painted
Install standard single HPT door and window to match, remaining space to be bricked up, plastered and painted
Install standard single HPT and new window.
Remaining space to be bricked up, plastered and painted.
Install custom size single HPT door
Install ful height window to match
New 230mm brick wall at 1065mm height to match existing bricks height
Fix balustrade to ramp, handrail height
1065mm,handrail diameter 30mm
Driveway to be repaved
Install wall mounted handrail
Install wall mounted handrail
N ew
BI
Courtyard level to increase to match landing at -187
Install wall mounted handrail
Install wall mounted handrail
Install guardrail
115mm wall at 1100mm height
Built in desk
300x3550mm Timber Panel 950
EXIST. Paved Walkway
New Door
New Door
New Door
New Door
N ew
D oo r
New Door
New Door
Existing Roof Line
Ex is tin g
R oo f L in e
Ex is tin g
R oo f L in e
N
EW
. fill and grass
Parking floor to be made good again this plaster
Mesh grating to be placed over exposed stormwater pipe
U P
Storeroom to be repainted externally
Existing service pipes to be protected, electrical cables to be used for boundary wall + ramp lighting
New Door
Soakaway below to assist with water drainage
New retaining wall as per structural eng specs
614 1378
Existing half brick wall
Existing half brick w all
New grass to be planted
Ex is tin g he dg es to re m ai n
New drainage to bathroom to comply with
SANS 10400
New drainage to connect to existing lines to manhole
310mm handrail extensions on all courtyard handrails
GROUND FLOOR PLAN PROPOSED NEW LAYOUT
Scale 1:75
GENERAL NOTES
1.All materials and workmanship are to comply with the relevant S.A.B.S codes 2.This drawing is not to be scaled. Figured dimensions to be used. All dimensions are in millimetres unless otherwise stated
3. This drawing must be read in conjunction with all the relevant drawings and specifications
4. Any discrepancies on the drawing are to be brought to the architect's attention by the contractor before putting work in hand
5. All dimensions and levels must be checked on site by the contractor before putting work
6. The contractor must obtain the Architect's written confirmation of any instruction which involve a variation to the contract before putting work in hand
7. All voids, suspended ceilings and partitions to be rodent proof in accordance with the government rodent proofing regulations
8. All mechanical and electrical work is to be done in accordance with the National Building Regulations
9. The contractor is to locate and identify any/all existing services and to protect these from damage whilst on site throughout the construction period
DRAINAGE NOTES
1. Access eyes to all bends and junctions and changes in gradient to waste and soil pipes.
2. All rodding eyes to have marked covers at ground level.
3. All waste pipes to be fully accessible.
4. Waste fittings to have 75mm deep seal traps.
5. Gradients to waste branches to be between 1,25 and 5.
6. Gradients to soil branches to be between 2,5 and 45.
7. All soil pipes under building to be encased in min 150mm concrete.
PROJECT : Design and Construction documentation of Accessibility upgrade 7 TREBYAM AVENUE, EDENBURG SANDTON
CLIENT: DRAWING NAME:
DRAWING FOR:DATE:
DRAWN BY:
Rebaone Molokwane
CHECKED BY:
Sundeep Jivan
SITE:
SCALE:
As per drawing
JOB NO: DRAWING NO: REVISION:
REV Date Description Dwn by: Ckd by:
COPYRIGHTS. THE DESIGN AND DRAWINGS REMAIN THE INTELLECTUAL PROPERTY RIGHTS OF
SAJ ARCHITECTS. THIS DOCUMENT MAY ONLY BE REPRODUCED WITH WRITTEN PERMISSION
OF SAJ ARCHITECTS. ALL RIGHTS RESERVED
SAJ ARCHITECTS
8 SAINT SEBASTIAN DRIVE
WENDYWOOD, SANDTON
CELL: 083560 4986
sundeepj@sajarc.com sajsundeep@gmail.com
SHEET NO:
01 December 2025
7 Trebyam Avenue, Edenburg, Sandton, Johannesburg, 2128.
U.S. Consulate General Johannesburg, South Africa
Issue for Construction
D
ES
IG
N
IS
SU
E
FO
R C
O N
ST
R
U C
TI
the express written approval of U.S. Department of State, Consulate General Johannesburg, 1 Sandton Drive, Sandhurst, Johannesburg, 2146, South Africa.
00 01 Dec 2025 R. Molokwane S.Jivan
WARNING
1. Ground Floor Plan Proposed New Layout
All handrails and balustrades require approved shop drawings before manufacturing and installation.
Floor Level Power: All floor level power outlets that are installed lower than 380mm above ffl, measured to the center of the outlet, should be moved to 400mm above ffl. All outlets throughout the main residence.
Light Switches: All light switches that are installed higher than 1200 mm above ffl, measured to the center of the switch, should be moved to 1200mm above ffl. All switches throughout the main residence
Trebyam Avenue
ERF RE/8/92
3m Building Line
3m Building Line
3m Building Line
3m Building Line
D rivew ay
Entrance
EXIST.
Parking
EXISTING PROPERTY
A
B
C
D
Boundary Line 56.67m
Boundary Line 43.50m
Boundary Line - 43.50m
Boundary Line 56.67m
EXIST.
Retaining wall
EX
IS
T.
sw im m in g po ol 1200
Edenburg Township
EXIST. Brick Wall
EXIST. Precast W all
EXIST. Precast Wall
Grass/Lawn
Grass/Lawn
MH
Grass/Lawn
New Ramp
EXIST.
Pavement
Finished Floor Level
U/S Ceiling
2725 Exist. plaster and paint
Exist. Timber Window
Remove existing tomber door and install standard single HPT door, window to match, remainder to be bricked up, plastered and painted.
Exist. Timber Window
Existing roof with concrete tiles
Exist. plaster and paint Exist. plaster and paint
Existing roof with concrete tiles
Exist.
plaster and paint
Chimney to be bricked up
NGL
NGL
U/S Ceiling
Finish Floor Level 3
-375 Existing aluminum window
Existing roof with concrete tiles
Existing mono pitched corrugated roof
Existing steel window
Existing Door
Existing steel window
Existing timber window
Existing timber windows
Existing roof with concrete tiles
Chimney to be silled.
Exist. plaster and paint
Exist. plaster and paint
Exist. plaster and paint Existing timber window
Exist. plaster and paint
Exist. plaster and paint
NGL
NGL
Bath WC
Sh ow er
Existing drain to municipal connection To municipal connection
Existing timber window
IEIE
IE IE IE
RE
Finished Floor Level
U/S Ceiling
Chimney to be silled.
Chimney to be silled.
Existing roof with concrete tilesExisting roof with concrete tiles
Existing retaining wall
Ex is tin g re ta in in g w al l
Ex is t.
co lu m n
Ex is t.
co lu m n
Ex is t.
co lu m n
Ex is t.
co lu m n
Exist. timber windowExist. plaster and paint
Exist. plaster and paint
EXIST.
Concrete Stair
NGL
New Door New Window to match, bottom part to be bricked up, plastered and painted.
Remove door, install standard single HPT door, window to match, remainder to be bricked up, plastered and painted.
Remove existing door, install standard style HPT door. Brick up remainder, plaster and paint.
Patio Roof note: Existing Harvey Tile Roof too shallow and to be replaced with Kliplock Roof sheeting but will depend on funding.
Rotting/damaged purlins on western side of roof to be replaced. QS will allow for 30% replacement on the roof subject to what we discover.
Box Gutter to be added
Finished Floor Level
U/S Ceiling
2725 Existing roof with concrete tiles
Existing roof with concrete tiles Chimney to be silled.
Chimney to be silled.
Exist. timber window
Exist. plaster and paint
Exist. timber window
Exist. plaster and paint
EXIST.
Concrete Stair
EXIST.
Covered patio
Ex is t.
co lu m nExist. plaster and paint
Exist. plaster and paint
Ex is t.
pl as te r an d pa in t
New 1200mm high balastrade
New 165 mm thick concrete Slab to match entrance slab
EXIST.
Concrete Stair
NGL
NGL
Patio Roof note: Existing Harvey Tile Roof too shallow and to be replaced with Kliplock Roof sheeting but will depend on funding.
Rotting/damaged purlins on western side of roof to be replaced.
QS will allow for 30% replacement on the roof subject to what we discover.
Box Gutter to be added
Finished Floor Level
U/S Ceiling
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation Exist.
Foundation
Existing timber window
Existing timber window
Existing timber window
Existing timber window
Existing roof with concrete tiles
Existing roof with concrete tiles
Existing roof with concrete tiles
Chimney to be silled.
Exist. Beam to structural eng spec
Existing roof with concrete tiles
New 1200mm high wall
New 800mm Run 1:10 Ramp
Exist.
Family Room
Exist.
Scullery
Exist Courtyard
Exist.
Passage
Exist.
Passage 3
Exist.
Passage 2
Exist.
Passage 1
Exist. Bedroom 3Exist.
plaster and paint
FFL Level on passage 2 to be raised 80mm higher
Cortyard to be lifted 313mm from Level -500 to -187
U/S Ceiling
Finish Floor Level 3
-375
Existing roof with concrete tiles
Existing timber window
Exist. plaster and paintExist. covered patio
Exist.
Lounge
Exist.
Kitchen
Exist.
Scullery
Exist.
Staffroom 2 Exist. plaster and paint
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation
Exist.
Foundation
New 165 mm thick concrete Slab to match entrance slab
Existing single sink to be replaced with a double sink with a toe and knee clearance
Existing roof with concrete tiles
New 450mm deep kitchen cupboards
New 1:12 Ramp
New concrete slabNew 350mm wide 1:10 Ramp
Existing mono pitched corrugated roof
Existing mono pitched corrugated roof
New 1200mm high balastrade
Ex is t.
co lu m n
Patio Roof note: Existing Harvey Tile Roof too shallow and to be replaced with Kliplock Roof sheeting but will depend on funding.
Rotting/damaged purlins on western side of roof to be replaced.
QS will allow for 30% replacement on the roof subject to what we discover.
Box Gutter to be added for drainage
SCHEDULE OF RIGHTS
ZONING INFORMATION
DEVELOPMENT CONTROL MEASURES
Permissible Control Actual
Height Zone
Coverage
Floor Area
PROPERTY DESCRIPTION
Erf / Portion:
Town Planning Scheme:
Site Area:
Title Deed No.:
EXISTING AREA:
ERF RE/8/92
Edernburg
2464.00 m²
Use Zone:
Amendment Scheme No:
Annexure No:
1 storey's3 storey's
60%
1232.00 m²
481.00 m2
COJ 2021
Residential 1
02-2021
481.00 m2
N/A
Floor Area Ratio- 0.19
21.99 %
NOTES
• No changes to Floor area and Coverage.
7.
Exist.
Family Room
4, Exist.
Breakfast Room
3.
Exist.
Dining Room
5.
Exist. Kitchen
1.
Exist.
Lobby
10.
Exist.
Bathroom2
. E xi st
. P as sa ge
9.
Bathroom1
19.
Exist.
Bathroom3
18.
Exist.
Bedroom2 / playroom
8.
Exist.
Bedroom 1
12.
Exist. Passage 3
12.
Exist.
Passage 2
13. Exist. Passage 1
14.
Exist.
Bedroom 4
17.
Exist.
Bathroom5
15.
Exist.
Bedroom 3
16.
Exist.
Bathroom4
BIC
BIC
21.
Exist.
Storeroom 1
23.
Exist.
Staffroom 2
22.
Exist.
Staffroom 4 24.
Exist.
Utility Room
25.
Exist.
Staffroom 1
Exist.
Gas
Cylinder Area
Ex is t C ou rt ya rd R ef er to R oo
D at a
Sh ee t
-1871
-1871 -1535
-165
BIC
2.
Exist.
Lounge
BIC
BIC
BIC
BIC
BICLine of existing beam overhead
6.
Exist.
Scullery
D
D
N ew
:1
R am p
1:12 Ramp
UP
Storeroom to be lifted 174mm from Level -174 to +0
New Slab
1:12 Ramp 355010
D
New Bath
WHB
WC
Sh ow er ø1525
Chimney to be bricked up to match the existing wall material and finish
Chimney to be bricked up to match the existing wall material and finish
New 165 mm thick concrete slab to match entrance slab
1:12 Ramp12
1388 700
Existing retaining wall
EXIST.
Planting
Drivew ay
EXIST.
Grass/Lawn
EXIST.
Planting
EXIST.
Grass/Lawn
EXIST.
Grass/Lawn
EXIST.
Grass/Lawn
A A
B
B
Access aisles
26.
Existing Parking
Existing ramp
D B
DB
EXIST.
Pavement
-174
Existing covered patio
-165
EXIST.
Concrete Stair
UP
3m Building Line
3m Building Line
EXIST. Precast Wall
Install custom size single HPT door.
Existing Roof Line
Existing Roof Line
Ex is tin g
R oo f L in e
Ex is tin g
R oo f L in e Ex is tin g R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Existing Roof Line
Ex is tin g
R oo f L in e
Exis tin g R oo f L ine
Ex is tin g
R oo f L in e
-1535
-187
C on cr et e st ai r
0m m ri se r
0m m tr ea d
-13
New walkway - Max 1:20 slope
New 1:12 Ramp
New ramp
Landing
EXIST.
Concrete Stair
Exist.
Storeroom 2
EXIST.
Pavem ent Existing retaining w all to be replasted
Existing Storm water drain pipe
Existing Drain Channel
Existing drainage to municipal connection G
Existing drainage to municipal connection Existing Storm water drain pipe
Existing Storm water drain pipe
G
Ex is tin g dr ai na ge un ic ip al c on ne ct io n Ex is tin g R oo f L in e
All switches to be moved to 1200mm from FFL to centerline of plug point.
All low plug points to be moved to 400mm from FFL to centerline of plug point.
New Tile
New Tile
New Tile
New Tile
New Tile, self-leveling screed from fireplace level to line up with lobby level.
UP
2086 4883
N ew w alkw ay - M ax 1:20 slope
N ew w al kw ay
M ax
:2 sl op e
New walkway - Max
1:20 slope
NEW.
Grass/Lawn
1825 600 1710
-593 -469
-339
-764
-902
610 5510
New Proposed drainage pipes to be placed on opposite South facing wall
N ew
D oo r
New Luxury Vinyl Tile with self-leveling screed.
New Tile
New Luxury Vinyl Tile with self-leveling screed.
New Luxury Vinyl Tile with self-leveling screed.
625 300300
New Luxury Vinyl Tile with self-leveling screed.
Ramp to be made good again with plaster
Install standard single HPT door. Remaining space to be bricked up, plastered and painted.
New Window to match, bottom part to be bricked up, plastered and painted
Install standard single HPT door and window to match, remaining space to be bricked up, plastered and painted
Install standard single HPT and new window.
Remaining space to be bricked up, plastered and painted.
Install custom size single HPT door
Install ful height window to match
New 230mm brick wall at 1065mm height to match existing bricks height
Fix balustrade to ramp, handrail height
1065mm,handrail diameter 30mm
Driveway to be repaved
BI
Courtyard level to increase to match landing at -187
Install wall mounted handrail
Built in desk
EXIST. Paved Walkway
New Door New Door
New Door
New Door
D oo r
New Door
Existing Roof Line
Ex is tin g
R oo f L in e
Ex is tin g
R oo f L in e
N
EW
. fill and grass
Parking floor to be made good again this plaster
U P
Storeroom to be repainted externally
Existing service pipes to be protected, electrical cables to be used for boundary wall + ramp lighting
New Door
Soakaway below to assist with water drainage
New retaining wall as per structural eng specs
614 1378
Existing half brick wall
Existing half brick w all
New grass to be planted
Ex is tin g he dg es to re m ai n
GENERAL NOTES
1.All materials and workmanship are to comply with the relevant S.A.B.S codes 2.This drawing is not to be scaled. Figured dimensions to be used. All dimensions are in millimetres unless otherwise stated
3. This drawing must be read in conjunction with all the relevant drawings and specifications
4. Any discrepancies on the drawing are to be brought to the architect's attention by the contractor before putting work in hand
5. All dimensions and levels must be checked on site by the contractor before putting work
6. The contractor must obtain the Architect's written confirmation of any instruction which involve a variation to the contract before putting work in hand
7. All voids, suspended ceilings and partitions to be rodent proof in accordance with the government rodent proofing regulations
8. All mechanical and electrical work is to be done in accordance with the National Building Regulations
9. The contractor is to locate and identify any/all existing services and to protect these from damage whilst on site throughout the construction period
DRAINAGE NOTES
1. Access eyes to all bends and junctions and changes in gradient to waste and soil pipes.
2. All rodding eyes to have marked covers at ground level.
3. All waste pipes to be fully accessible.
4. Waste fittings to have 75mm deep seal traps.
5. Gradients to waste branches to be between 1,25 and 5.
6. Gradients to soil branches to be between 2,5 and 45.
7. All soil pipes under building to be encased in min 150mm concrete.
PROJECT : Design and Construction documentation of Accessibility upgrade 7 TREBYAM AVENUE, EDENBURG SANDTON
CLIENT: DRAWING NAME:
DRAWING FOR:DATE:
DRAWN BY:
Rebaone Molokwane
CHECKED BY:
Sundeep Jivan
SITE:
SCALE:
As per drawing
JOB NO: DRAWING NO: REVISION:
REV Date Description Dwn by: Ckd by:
COPYRIGHTS. THE DESIGN AND DRAWINGS REMAIN THE INTELLECTUAL PROPERTY RIGHTS OF
SAJ ARCHITECTS. THIS DOCUMENT MAY ONLY BE REPRODUCED WITH WRITTEN PERMISSION
OF SAJ ARCHITECTS. ALL RIGHTS RESERVED
SAJ ARCHITECTS
8 SAINT SEBASTIAN DRIVE
WENDYWOOD, SANDTON
CELL: 083560 4986
sundeepj@sajarc.com sajsundeep@gmail.com
SHEET NO:
01 December 2025
7 Trebyam Avenue, Edenburg, Sandton, Johannesburg, 2128.
U.S. Consulate General Johannesburg, South Africa
Issue for Construction
D
ES
IG
N
IS
SU
E
FO
R C
O N
ST
R
U C
TI
the express written approval of U.S. Department of State, Consulate General Johannesburg, 1 Sandton Drive, Sandhurst, Johannesburg, 2146, South Africa.
00 01 Dec 2025 R. Molokwane S.Jivan
WARNING
1. Proposed New Ground Floor Plan
2. Site Plan
3. Schedule of Rights
4. Section AA
5. Section BB
6. North Elevation
7. South Elevation
8. East Elevation
9. West Elevation
NORTH ELEVATION
Scale 1:100
EAST ELEVATION
Scale 1:100
WEST ELEVATION
Scale 1:100
SOUTH ELEVATION
Scale 1:100
SECTION BB
Scale 1:100
SECTION AA
Scale 1:100
SITE PLAN
Scale 1:500
PROPOSED NEW GROUND FLOOR PLAN
Scale 1:100
-220
-220 -220
-165
Existing covered patio
Existing paving
1200 1600
Ex is tin g
0m m h ig h br ic k w al l
Existing 300mm high brick wall
Ex is tin g re ta in in g w al l
C
C
Trebyam Avenue
ERF 19/92
ERF 20/92
ERF RE/8/92
ERF 4/92
3m Building Line
3m Building Line
3m Building Line
3m Building Line
D rivew ay
Entrance
EXIST.
Parking
EXISTING PROPERTY
A
B
C
D
Boundary Line 56.67m
Boundary Line 43.50m
Boundary Line - 43.50m
Boundary Line 56.67m
ERF 4/92
EXIST.
Retaining wall
EX
IS
T.
sw im m in g po ol
Edenburg Township
EXIST. Brick Wall
EXIST. Precast W all
EXIST. Precast Wall
Grass/Lawn
Grass/Lawn
MH
Grass/Lawn
New Ramp
EXIST.
Pavement
-650
-220
-900
Pool Ramp Section
Grass/Lawn
C
C
N ew
R am p
New RampN ew
R am p
New Ramp
New Pool Fence
Existing patio floor
Existing pool paving
GENERAL NOTES
1.All materials and workmanship are to comply with the relevant S.A.B.S codes 2.This drawing is not to be scaled. Figured dimensions to be used. All dimensions are in millimetres unless otherwise stated
3. This drawing must be read in conjunction with all the relevant drawings and specifications
4. Any discrepancies on the drawing are to be brought to the architect's attention by the contractor before putting work in hand
5. All dimensions and levels must be checked on site by the contractor before putting work
6. The contractor must obtain the Architect's written confirmation of any instruction which involve a variation to the contract before putting work in hand
7. All voids, suspended ceilings and partitions to be rodent proof in accordance with the government rodent proofing regulations
8. All mechanical and electrical work is to be done in accordance with the National Building Regulations
9. The contractor is to locate and identify any/all existing services and to protect these from damage whilst on site throughout the construction period
DRAINAGE NOTES
1. Access eyes to all bends and junctions and changes in gradient to waste and soil pipes.
2. All rodding eyes to have marked covers at ground level.
3. All waste pipes to be fully accessible.
4. Waste fittings to have 75mm deep seal traps.
5. Gradients to waste branches to be between 1,25 and 5.
6. Gradients to soil branches to be between 2,5 and 45.
7. All soil pipes under building to be encased in min 150mm concrete.
PROJECT : Design and Construction documentation of Accessibility upgrade 7 TREBYAM AVENUE, EDENBURG SANDTON
CLIENT: DRAWING NAME:
DRAWING FOR:DATE:
DRAWN BY:
Rebaone Molokwane
CHECKED BY:
Sundeep Jivan
SITE:
SCALE:
As per drawing
JOB NO: DRAWING NO: REVISION:
REV Date Description Dwn by: Ckd by:
COPYRIGHTS. THE DESIGN AND DRAWINGS REMAIN THE INTELLECTUAL PROPERTY RIGHTS OF
SAJ ARCHITECTS. THIS DOCUMENT MAY ONLY BE REPRODUCED WITH WRITTEN PERMISSION
OF SAJ ARCHITECTS. ALL RIGHTS RESERVED
SAJ ARCHITECTS
8 SAINT SEBASTIAN DRIVE
WENDYWOOD, SANDTON
CELL: 083560 4986
sundeepj@sajarc.com sajsundeep@gmail.com
SHEET NO:
01 December 2025
7 Trebyam Avenue, Edenburg, Sandton, Johannesburg, 2128.
U.S. Consulate General Johannesburg, South Africa
Issue for Construction
D
ES
IG
N
IS
SU
E
FO
R C
O N
ST
R
U C
TI
the express written approval of U.S. Department of State, Consulate General Johannesburg, 1 Sandton Drive, Sandhurst, Johannesburg, 2146, South Africa.
00 01 Dec 2025 R. Molokwane S.Jivan
WARNING
1200 x 1200mm concrete pad for possible pool lift
Proposed New Clearview fence to be installed around pool to manufacturers specification
Fence to have self-closing gate at a mini-mum of 1200m according to
SANS10400
SITE PLAN
Scale 1:200
Proposed new paving and retaining wall
1:12 Ramp to engineer's specs. No handrail is required if the landscaping is regraded to meet the same level.
Existing garden to be landscaped up to new concrete slab.
PROPOSED POOL FENCE AND RAMP LAYOUT
Scale 1:50
ClearVu posts to be positioned on the grass area
C le ar Vu p os ts to b e si tu at ed o n pr op os ed n ew c on cr et e
ClearVu posts to be situated on existing patio
SECTION CC
Scale 1:50
Self-closing Magnetic Pool Safety Gate Latch
1. Site Plan
2. Section CC
3. Proposed Pool Fence and Ramp Layout
1200x535mm Stainless Steel Drop on Franke kitchen sink
685mm high Knee Clearance
230mm high Toe Clearance
16mm thick Removable Formica Timber Panels in same colour as kitchen cupboards
92 197
Finished Floor Level
U/S Ceiling
New Door
1032460915
Panel to conceal sink
Angled panel to conceal pipes
OPEN BEYOND
Timber Panel
600mm wide granite counter to match existing at 860mm affl
Cupboard door handles to match existing handles
White subway tile backsplash to match existing
16mm thick white formica cupboard & drawer by specialist.
50mm recessed kickplate
Finished Floor Level
U/S Ceiling
Cupboard door handles to match existing handles
16mm thick white formica cupboard & drawer by specialist.
50mm recessed kickplate
New Cornice
New board to fill gap to be painted to match existing kitchen units
New Cupboards with shelves24
New Dishwasher
10 491 20 492 20 492 10
New Cornice
New board to fill gap to be painted to match existing kitchen units
New BIC
New Window
N ew
D oo r
N ew
D oo r
New single combined front-loading washer/dryer
New dishwasher
16 376 16 376 16
N ew
B ro om c lo se t
New shelves
Finished Floor Level
U/S Ceiling
Panel to conceal basins
Angled panel to conceal pipes
Finished Floor Level
U/S Ceiling
525x405mm Duravit Soleil Vanity Basin White
685mm high Knee Clearance
230mm high Toe Clearance
16mm thick Removable Formica Timber Panels in same colour as kitchen cupboards
Finished Floor Level
U/S Ceiling
Cupboard door handles to match existing handles
16mm thick white formica cupboard & drawer by specialist.
50mm recessed kickplate
New Cornice
New board to fill gap to be painted to match existing kitchen units
GENERAL NOTES
1.All materials and workmanship are to comply with the relevant S.A.B.S codes 2.This drawing is not to be scaled. Figured dimensions to be used. All dimensions are in millimetres unless otherwise stated
3. This drawing must be read in conjunction with all the relevant drawings and specifications
4. Any discrepancies on the drawing are to be brought to the architect's attention by the contractor before putting work in hand
5. All dimensions and levels must be checked on site by the contractor before putting work
6. The contractor must obtain the Architect's written confirmation of any instruction which involve a variation to the contract before putting work in hand
7. All voids, suspended ceilings and partitions to be rodent proof in accordance with the government rodent proofing regulations
8. All mechanical and electrical work is to be done in accordance with the National Building Regulations
9. The contractor is to locate and identify any/all existing services and to protect these from damage whilst on site throughout the construction period
DRAINAGE NOTES
1. Access eyes to all bends and junctions and changes in gradient to waste and soil pipes.
2. All rodding eyes to have marked covers at ground level.
3. All waste pipes to be fully accessible.
4. Waste fittings to have 75mm deep seal traps.
5. Gradients to waste branches to be between 1,25 and 5.
6. Gradients to soil branches to be between 2,5 and 45.
7. All soil pipes under building to be encased in min 150mm concrete.
PROJECT : Design and Construction documentation of Accessibility upgrade 7 TREBYAM AVENUE, EDENBURG SANDTON
CLIENT: DRAWING NAME:
DRAWING FOR:DATE:
DRAWN BY:
Rebaone Molokwane
CHECKED BY:
Sundeep Jivan
SITE:
SCALE:
As per drawing
JOB NO: DRAWING NO: REVISION:
REV Date Description Dwn by: Ckd by:
COPYRIGHTS. THE DESIGN AND DRAWINGS REMAIN THE INTELLECTUAL PROPERTY RIGHTS OF
SAJ ARCHITECTS. THIS DOCUMENT MAY ONLY BE REPRODUCED WITH WRITTEN PERMISSION
OF SAJ ARCHITECTS. ALL RIGHTS RESERVED
SAJ ARCHITECTS
8 SAINT SEBASTIAN DRIVE
WENDYWOOD, SANDTON
CELL: 083560 4986
sundeepj@sajarc.com sajsundeep@gmail.com
SHEET NO:
01 December 2025
7 Trebyam Avenue, Edenburg, Sandton, Johannesburg, 2128.
U.S. Consulate General Johannesburg, South Africa
Issue for Construction
D
ES
IG
N
IS
SU
E
FO
R C
O N
ST
R
U C
TI
the express written approval of U.S. Department of State, Consulate General Johannesburg, 1 Sandton Drive, Sandhurst, Johannesburg, 2146, South Africa.
00 01 Dec 2025 R. Molokwane S.Jivan
WARNING
PROPOSED KITCHEN SINK JOINERY
SECTION
Scale 1:20
PROPOSED KITCHEN SINK JOINERY
ELEVATION
Scale 1:20
PROPOSED KITCHEN SINK JOINERY
Scale 1:20
PROPOSED KITCHEN TALL CUPBOARD JOINERY
ELEVATION
Scale 1:20
PROPOSED SCULLERY CUPBOARD JOINERY ELEVATION
Scale 1:20
PROPOSED KITCHEN TALL CUPBOARD JOINERY
SECTION
Scale 1:20
PROPOSED BATHROOM VANITY JOINERY ELEVATION
Scale 1:20
PROPOSED BATHROOM VANITY JOINERY SECTION
Scale 1:20
PROPOSED SCULLERY CUPBOARD JOINERY SECTION AND OPEN CUPBOARD ELEVATION
Scale 1:20
1. Joinery Layout
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D01 - HPT Security Door Exist. Lobby
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
DOUBLE DOOR
(internal) D02
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D03 - Solid Core Door Exist. Lobby
New customized 44mm thick Solid-core door with new timber frame
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
N/A
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D04
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
SINGLE DOOR
(internal) D05 - Solid Core Door
Exist. Bedroom 1
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D06 - Solid Core Door New Bathroom 1
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D08
DOOR
SIZE
GLAZING
SIGNAGE
Scale 1:50
New customized 44mm thick Solid-core door with new timber frame
930 x 2032 x 44mm (x 1 leaf)
N/A
New min 32mm Timber Frame with a single rebate to accommodate larger door
New timber frame to be cleaned, sanded, and varnished
Drawing ScaleScale 1:50Drawing Scale Scale 1:50Drawing Scale
Scale 1:50Drawing ScaleScale 1:50Drawing ScaleScale 1:50Drawing ScaleScale 1:50Drawing Scale
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
U/S Lintel
Section View
Ex te rn al
In te
Ex is tin g
Br ic k
W al l Concrete lintel beam as per engineers specExisting
Brick Wall
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
U/S Lintel
Section View
Ex te k
W al l Concrete lintel beam as per engineers specExisting
Brick Wall
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
Section View
In te k W al l
Concrete lintel beam as per engineers spec
Existing Brick Wall
930 32
32 930 32
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
Section View
In te k W al l
Concrete lintel beam as per engineers spec
Existing Brick Wall
930 32
32 930 32
EX
IS
TI
NG
D
OOR
TO
B E
RE
M
OVE
D
AN
D
OPE
NI
NG
T
O R
EM
AI
N
EX
IS
TI
NG
D
OOR
TO
B E
RE
M
OVE
D
AN
D
CL
EA
R
OPE
NI
NG
S
IZ
E
TO
B E
IN
CR
EA
SE
D
DO
OR
TO
B E
RE
M
OVE
D
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
U/S Lintel
Section View
In te k
W al l Concrete lintel beam as per engineers specExisting
Brick Wall
32 930 32
32 930 32
N/A
930 x 2032 x 32mm (x 1 leaf)
N/A
New 32mm Timber Frame with a single rebate to accommodate larger door
New timber frame to be cleaned, sanded, and varnished
N/A
SINGLE DOOR
(internal)
CUSTOM SINGLE DOOR
(external)
New Custom Single HPT Door
N/A
Steel Reinforced Frame
Door clearing to be achieved to comply with ADA requirements. Manufacturer to confirm size of brick opening required and size of frame
N/A
New 32mm Timber Frame with a single rebate to accommodate larger door
New Brickwork
New Custom HPT Single Door
U/S Lintel
U/S Lintel2125
600 600
30 1140 30
N/A
930 x 2032 x 44mm (x 1 leaf)
SINGLE DOOR
(internal)
SINGLE DOOR
(internal)
SINGLE DOOR
(internal)
Space beside New HPT door to be bricked up, plastered and painted and made good.
Hinges - Stainless steel hinges (x3) Handle - Pello Stainless steel solid single lever handle by QS (x2) Lock Type - Stainless steel Cylinder 2 or 3 lever lockset (x1)
Hinges - Stainless steel hinges (x3) Handle - Pello Stainless steel solid single lever handle by QS (x2) Lock Type - Stainless steel Cylinder 2 or 3 lever lockset (x1)
Hinges - Stainless steel hinges (x3) Handle - Pello Stainless steel solid single lever handle by QS (x2) Lock Type - Stainless steel Cylinder 2 or 3 lever lockset (x1)
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
SINGLE DOOR
(external) R01, R02, R03, R04 - Exist.
Solid Core Doors Exist. Bathrooms 2, 3, 4 & 5
DOOR
SIZE
GLAZING
SIGNAGE
Existing Bathroom doors to remain but existing ironmongery to be replaced with new door handles to match new doors
Scale 1:50Drawing Scale
Existing Bathroom door frames to remain
Existing handles and locks to be replaced to match new doors
Handle - Pello Stainless steel solid single lever handles (x2) Lock Type - Stainless steel Cylinder 2 or 3 lever lockset (x1)
External
Internal
Clear opening
Overall Frame Width to Manufacturer Specification
New timber frame to be cleaned, sanded, and varnished
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
U/S Lintel
Section View
Ex te k W al l Concrete lintel beam as per engineers specExisting Brick Wall 946
Elevation View
Elevation Plan View
Section View Elevation View
Elevation Plan View
Section View
New customized 44mm thick Solid-core door with new timber frame
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
2 x High Gloss Enamel Finishing Coats
2 x High Gloss Enamel Finishing Coats
As per manufacturer's specification
As per manufacturer's specifications
As per manufacturer's specifications
As per manufacturer's specifications
As per manufacturer's specifications
Only Ironmongery on existing doors to be replaced to match new handles and locks
Exit. FFL
Door Handle
U/S Lintel
Ex te k W al l Concrete lintel beam as per engineers specExisting Brick Wall 946
Exit. FFL
Door Handle
U/S Lintel
Ex te k W al l Concrete lintel beam as per engineers specExisting Brick Wall 946
Note: All openings for custom HPT Doors to be 1050 wide and 2075 high.
Openings to be verified by Manufacturer.
GENERAL NOTES
1.All materials and workmanship are to comply with the relevant S.A.B.S codes 2.This drawing is not to be scaled. Figured dimensions to be used. All dimensions are in millimetres unless otherwise stated
3. This drawing must be read in conjunction with all the relevant drawings and specifications
4. Any discrepancies on the drawing are to be brought to the architect's attention by the contractor before putting work in hand
5. All dimensions and levels must be checked on site by the contractor before putting work
6. The contractor must obtain the Architect's written confirmation of any instruction which involve a variation to the contract before putting work in hand
7. All voids, suspended ceilings and partitions to be rodent proof in accordance with the government rodent proofing regulations
8. All mechanical and electrical work is to be done in accordance with the National Building Regulations
9. The contractor is to locate and identify any/all existing services and to protect these from damage whilst on site throughout the construction period
DRAINAGE NOTES
1. Access eyes to all bends and junctions and changes in gradient to waste and soil pipes.
2. All rodding eyes to have marked covers at ground level.
3. All waste pipes to be fully accessible.
4. Waste fittings to have 75mm deep seal traps.
5. Gradients to waste branches to be between 1,25 and 5.
6. Gradients to soil branches to be between 2,5 and 45.
7. All soil pipes under building to be encased in min 150mm concrete.
PROJECT : Design and Construction documentation of Accessibility upgrade 7 TREBYAM AVENUE, EDENBURG SANDTON
CLIENT: DRAWING NAME:
DRAWING FOR:DATE:
DRAWN BY:
Rebaone Molokwane
CHECKED BY:
Sundeep Jivan
SITE:
SCALE:
As per drawing
JOB NO: DRAWING NO: REVISION:
REV Date Description Dwn by: Ckd by:
COPYRIGHTS. THE DESIGN AND DRAWINGS REMAIN THE INTELLECTUAL PROPERTY RIGHTS OF
SAJ ARCHITECTS. THIS DOCUMENT MAY ONLY BE REPRODUCED WITH WRITTEN PERMISSION
OF SAJ ARCHITECTS. ALL RIGHTS RESERVED
SAJ ARCHITECTS
8 SAINT SEBASTIAN DRIVE
WENDYWOOD, SANDTON
CELL: 083560 4986
sundeepj@sajarc.com sajsundeep@gmail.com
SHEET NO:
01 December 2025
7 Trebyam Avenue, Edenburg, Sandton, Johannesburg, 2128.
U.S. Consulate General Johannesburg, South Africa
Issue for Construction
D
ES
IG
N
IS
SU
E
FO
R C
O N
ST
R
U C
TI
the express written approval of U.S. Department of State, Consulate General Johannesburg, 1 Sandton Drive, Sandhurst, Johannesburg, 2146, South Africa.
00 01 Dec 2025 R. Molokwane S.Jivan
WARNING
1. New Door Schedule_001
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D09 - Solid Core Door Exist. Bedroom 2
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D11
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D13 - Solid Core Door Exist. Bedroom 4
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D14 - Solid Core Door Exist. Bedroom 3
DOOR
SIZE
GLAZING
SIGNAGE
Scale 1:50Drawing ScaleScale 1:50Drawing ScaleDrawing ScaleScale 1:50Drawing Scale
Elevation View
Elevation Plan View
Section View
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
Section View
In te k W al l
Concrete lintel beam as per engineers spec
Existing Brick Wall
930 32
32 930 32
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
Section View
In te k W al l
Concrete lintel beam as per engineers spec
Existing Brick Wall
930 32
32 930 32
DO
OR
T
O B E
RE
M
OVE
D
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
Section View
In te k W al l
Concrete lintel beam as per engineers spec
Existing Brick Wall
930 32
32 930 32
U/S Lintel U/S LintelU/S Lintel
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D17 - HPT Security Door Exist. Bedroom 3
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D18
DOOR
SIZE
GLAZING
SIGNAGE
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
D19 - Exist. Pocket Door Exist. Dinner Room
DOOR
SIZE
GLAZING
SIGNAGE
Scale 1:50Drawing ScaleScale 1:50Drawing ScaleDrawing Scale
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
U/S Lintel
Section View
Ex te k W al l Concrete lintel beam as per engineers specExisting Brick Wall 927
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
Section View
In te k W al l Concrete lintel beam as per engineers spec
Existing Brick Wall U/S Lintel
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
U/S Lintel
Section View
Ex te k
W al l Concrete lintel beam as per engineers specExisting
Brick Wall
Top of Door Existing WindowExisting Window
EX
IS
TI
NG
D
OOR
T
O B E
RE
M
OVE
D
AN
D
RE
PL
AC
ED
W
IT
H W
IN
DO
W
133 1140
930 x 2032 x 32mm (x 1 leaf)
N/A
New 32mm Timber Frame with a single rebate to accommodate larger door
New timber frame to be cleaned, sanded, and varnished
N/A
SINGLE DOOR
(internal)
SINGLE DOOR
(internal)
930 x 2032 x 32mm (x 1 leaf)
N/A
New 32mm Timber Frame with a single rebate to accommodate larger door
New timber frame to be cleaned, sanded, and varnished
N/A
SINGLE DOOR
(internal)
930 x 2032 x 32mm (x 1 leaf)
N/A
New 32mm Timber Frame with a single rebate to accommodate larger door
Door Frame:
New timber frame to be cleaned, sanded, and varnished
N/A
SINGLE DOOR
(internal)
SINGLE DOOR
(external) DOUBLE DOOR
(external)
Existing Sliding door to remain
1140 x 2032 x 32mm (x 1 leaf)
N/A
N/A
SINGLE SLIDING DOOR
(internal)
1540 1800 1530
Scale 1:50
Hinges - Stainless steel hinges (x3) Handle - Pello Stainless steel solid single lever handle by QS (x2) Lock Type - Stainless steel Cylinder 2 or 3 lever lockset (x1)
Hinges - Stainless steel hinges (x3) Handle - Pello Stainless steel solid single lever handle by QS (x2) Lock Type - Stainless steel Cylinder 2 or 3 lever lockset (x1)
Hinges - Stainless steel hinges (x3) Handle - Pello Stainless steel solid single lever handle by QS (x2) Lock Type - Stainless steel Cylinder 2 or 3 lever lockset (x1)
Sliding mechanism to be cleaned and oiled to ensure door to runs smoothly
FRAME
DESCRIPTION
FRAME FINISH
FRAME SIZE
IRONMONGERY
NOTES
DOOR
NUMBER
DOOR
DESCRIPTION
DOOR
FINISH
DOUBLE DOOR
(internal) D20
DOOR
SIZE
GLAZING
SIGNAGE
Scale 1:50Drawing Scale
Elevation View
Elevation Plan View
Exit. FFL
Door Handle
U/S Lintel
Section View
Ex te k
W al l Concrete lintel beam as per engineers specExisting
Brick Wall
DO
OR
T
O B E
RE
M
OVE
D
AN
D
OPE
NI
NG
T
O R
EM
AI
N
External
Internal
600 600
30 1140 30
Scale 1:50
New Standard Single HPT Door
N/A
Steel Reinforced Frame
Door clearing to be achieved to comply with ADA requirements. Manufacturer to confirm size of brick opening required and size of frame
As per manufacturer's specification
N/A
Spaces beside New HPT door to be bricked up, plastered and painted and made good
New Brickwork
New customized 44mm thick Solid-core door with new timber frame
New customized 44mm thick Solid-core door with new timber frame
New customized 44mm thick Solid-core door with new timber frame
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
1 x Timber Primer Coat 1 x Universal Undercoat 2 x High Gloss Enamel Finishing Coats
As per manufacturer's specifications
As per manufacturer's specifications
As per manufacturer's specifications
As per manufacturer's specifications
Exit. FFL
Door Handle
U/S Lintel
Ex te k W al l Concrete lintel beam as per engineers specExisting Brick Wall 946
Overall frame width to manufacturer specification
Note: All openings for standard single HPT Doors to be 895 wide and 2075 high.
This is the start of the file's text. The full file is on GovTribe.