The project scope includes general conditions, pavement and building repairs, grading, storm sewer, waterproofing, HVAC replacement, ductwork, masonry, and carpentry. The contractor will have 180 calendar days to complete the work from the notice to proceed date. The estimated contract value is between $1,000,000 and $5,000,000. The procurement is 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) who must be verified and registered in the VA's Vendor Information Pages prior to submitting a proposal. The solicitation number is 36C78624B0027 and the contracting officer is Shane Hilts.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING
BUILDING
BUILDING
CBMH-3
RIM 462.56
INV 454.43 (8" OUT)
CBMH-2
RIM 460.90
INV 453.19 (8" IN)
INV 452.28 (8" OUT)
62 LF 8" HDPE @ 2.00%
EX CB-1
RIM 453.36
INV 449.30 (8" IN)
INV 451.80 (4" IN)
INV 449.30 (12" OUT)
7 LF 8" HDPE @ 5.00%
CBMH-4
RIM 461.98
INV 458.27 (8" OUT)
8 LF 8" HDPE @ 1.00%
EX CBMH-5
RIM 460.92
INV 457.60 (8" IN)
INV 453.20 (4" IN)
INV 453.2 (12" OUT)
25 LF 8" HDPE @ 1.00%
53 LF 8" HDPE @ 5.00%
34 LF 8" HDPE @
1.00%
TC 462.60
TC 462.50
TC 462.60
TC 462.50
FG 460.50
FG 462.7
FG 462.6
EX MH
RIM 452.50
E. INV 449.7 (18" IN)
N. INV 446.7 (18" OUT)
SW. INV 446.7 (18" OUT)
EX MH
RIM 453.00
E. INV 447.8 (18" IN)
N. INV 447.8 (12" IN)
SW. INV 447.7 (18" OUT)
EX MH
RIM 453.00
SE. INV 448.80 (15" IN)
N. INV 450.1 (12" IN)
NW. INV 448.7 (12" IN)
SW. INV 448.6 (18" OUT)
EX MH
RIM 453.40
E. INV 449.5 (15" IN)
NW. INV 449.2 (15" OUT)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 17550
JEFFERSON BARRACKS
NATIONAL CEMETERY
CORRECT FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
MARCH 28, 2024
852CM3042
Fi le
P at h:
c
:\u se rs \e br od m ar kl e\ de sk to p\ ne w lo go
\v as he et x4
2-ne w lo go -2
3.
dw g ed it:
eb ro dm ar kl e sa ve d:
1/
/2
8:
A M p lo t:1 /1
6/
:0
A M
KEY MAP N.T.S.
CONSULTANTS
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314)-692-5195
03/28/2024
BUILDING 3001 GRADING
AND DRAINAGE PLAN
CG401
0 10' 20' N
LEGEND
PROPERTY LIMITS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
SILT FENCE
INLET PROTECTION 1
INLET PROTECTION 2
EXISTING GAS MAIN
EXISTING SANITARY SEWER
EXISTING STORM SEWER
EXISTING UNDERGROUND ELECTRIC
EXISTING COMMUNICATIONS
PROPOSED STORM SEWER
PROPOSED FOUNDATION DRAINTILE, SEE
DETAIL 5/CS501.
PROPOSED STORM INLETS
PROPOSED STORM BEND
TOP OF CURB ELEVATION
FINISHED GRADE ELEVATION
KEY NOTES
INSTALL NEW DRAINTILE AT BASE OF BUILDING
FOOTING
INSTALL NEW CATCH BASIN SEE DETAIL 10/CS501
INSTALL NEW STORM SEWER TO COLLECT ROOF
DRAINS. SEE DETAIL 5/CS501.
CORE DRILL DRAIN TILE AND HDPE INTO
EXISTING CATCH BASINS (TYPICAL).
20 LF DRAINTILE (TYPICAL). SEE DETAIL 7/CS502.
C
STORM STRUCTURE SCHEDULE
TC 800.1
STORM BEND
STORM
BEND
NOTES
1) ALL DISTURBED AREAS SHALL RECEIVE TOPSOIL
AND SOD. SEE SPECIFICATION SECTION 32 90 00.
FG 800.1
EB SL
STORM BEND
PROPOSED FOUNDATION DRAINTILE
PROPOSED FOUNDATION DRAINTILE
PROPOSED DRAINTILE
FFE 454.20
FFE 454.20
FFE 454.20
AutoCAD SHX Text
STAIRS
AutoCAD SHX Text
GARY R JOHNSON
AutoCAD SHX Text
NUMBER PE-2012005390
AutoCAD SHX Text
STRUCTURE NUMBER
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
CASTING (NEENAH OR APPROVED EQUAL)
AutoCAD SHX Text
EX CB-1
AutoCAD SHX Text
AutoCAD SHX Text
CBMH-2
AutoCAD SHX Text
8" NYLOPLAST OR EQUAL
AutoCAD SHX Text
EJ-1573A OR EQUAL
AutoCAD SHX Text
CBMH-3
AutoCAD SHX Text
8" NYLOPLAST OR EQUAL
AutoCAD SHX Text
EJ-1573A OR EQUAL
AutoCAD SHX Text
CBMH-4
AutoCAD SHX Text
8" NYLOPLAST OR EQUAL
AutoCAD SHX Text
EJ-1573A OR EQUAL
AutoCAD SHX Text
EX CBMH-5
AutoCAD SHX Text
(2) VARIABLE
INVERT
HEIGHT 1.50"
6.50"
(2) VARIABLE
OVERALL
HEIGHT
6" MIN.
NOTES:
1. GRATES/SOLID COVER SHALL BE DUCTILE IRON
PER ASTM A536 GRADE 70-50-05.
2. DRAIN BASIN TO BE CUSTOM MANUFACTURED
ACCORDING TO PLAN DETAILS.
3. DRAINAGE CONNECTION STUB JOINT TIGHTNESS
SHALL CONFORM TOASTM D3212 FOR
CORRUGATED HDPE (ADS & HANCOR DUAL WALL)
& SDR 35 PVC
4. DIMENSIONS ARE FOR REFERENCE ONLY
5. ACTUAL DIMENSIONS MAY VARY
(1) DUCTILE IRON GRATE
(3,4) VARIOUS TYPES OF INLET &
OUTLET ADAPTERS AVAILABLE:
4" - 8" FOR CORRUGATED HDPE
(ADS N-12/HANCOR DUAL WALL,
ADS/HANCOR SINGLE WALL), PVC
SEWER (EX: SDR 35), PVC DWV
(EX: SCH 40), PVC C900/C905,
CORRUGATED & RIBBED PVC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
JEFFERSON BARRACKS
NATIONAL CEMETERY
CORRECT FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
MARCH 28, 2024
852CM3042
Fi le
P at h:
c
:\u se rs \e br od m ar kl e\ de sk to p\ ne w lo go
\v as he et x4
2-ne w lo go -2
3.
dw eb ro dm ar kl d:
1/
/2
8:
lo t:1 /1
6/
:0
A M
CONSULTANTS
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314)-692-5195
03/28/2024
CIVIL SITE DETAILS 1
CS501
SCALE:9
ASPHALT PAVEMENT SECTION
AT ADJOINING EXISTING CURB/PAVEMENTS
NTSSCALE:8
ASPHALT PAVEMENT SECTIONS
NTS
CURB
10" FILTER ASSEMBLY
OVERFLOW 2 - TOP OF
CURB BOX
OVERFLOW 1 - CENTER
OF FILTER ASSEMBLY
HIGH-FLOW FABRIC CG-23 HIGH FLOW
NOTE: DEPENDING UPON CONFIGURATION, ATTACH FABRIC TO
WIRE MESH WITH HOG RINGS, STEEL POSTS WITH TIE WIRES, OR
WOOD POSTS WITH STAPLES.
DIRECTION OF
RUNOFF FLOW
2' MIN
TYPICAL INSTALLATION
6" MIN.
6" MIN.
SCALE:1
SILT FENCE
NTS
SCALE:2
INLET SEDIMENT PROTECTION
(INLET PROTECTION 1)
NTS
SCALE:7
MILL & OVERLAY
CONTRACT OPTION 2
NTS
SCALE:4
8" AREA DRAIN
NTS
8"8"4" 6"
2'-0"
R
PT
/P C
R=31"
PT
71 4"
5"
4"
2"
3 #5 DOWELS @
EXPANSION JOINTS
R 12 "
R
SCALE:6
ROLL CURB
CONTRACT OPTION 1
NTS
SCALE:3
BIOROLL INLET PROTECTION
(INLET PROTECTION 2)
NTS SCALE:5
FOUNDATION DRAINTILE DETAIL
NTS
9' -4
7 8"
12"
APPROVED SUBGRADE BY
CONTRACTORS INDEPENDENT TESTING
AGENCY. SEE GEOTECH REPORT.
SAWCUT PAVEMENT FULL DEPTH
MoDOT TYPE 5 AGGREGATE SUBBASE
ASPHALT TACK COAT
FLUSH W/ADJACENT PAVEMENT
ACC SURFACE
ACC BASE
EX. PAVEMENT
EXISTING SUBGRADE
ASPHALT TACK COAT
ASPHALT
TACK COAT
EXISTING CONCRETE
CURB AND GUTTER
2" ACC SURFACE
2" ACC BASE
EX. PAVEMENT OR NEW
ROADWAY PAVEMENT
ASPHALT TACK COAT
ENGINEERING FABRIC
FABRIC ANCHORAGE TRENCH
BACKFILL WITH TAMPED
NATURAL SOILMETAL OR WOOD
POST OR STAKE
WIRE MESH
REINFORCEMENT
(OPTIONAL)
NATURAL SOIL
EXISTING METAL GUTTER
EXISTING METAL DOWNSPOUT
2% MIN. GRADE
AWAY FROM
BUILDING
WATERPROOFING,
SEE ARCH
CONCRETE
FOUNDATION AND PIER
4" PVC DRAINTILE
WRAPPED WITH DRAINAGE
AGGREGATE AND
GEOTEXTILE FABRIC
EXISTING AGGREGATE
BASE TO REMAIN
DEMO
INSTALL
NEW ROADWAY ASPHALT PAVEMENT
NEW PARKING ASPHALT PAVEMENT
6" TYPE MoDOT TYPE 5
AGGREGATE BASE
2" ACC SURFACE
4" ACC BASE
EX. PAVEMENT OR NEW
ROADWAY PAVEMENT
ASPHALT TACK COAT
6" TYPE MoDOT TYPE 5
AGGREGATE BASE
EB SL
1.5" ACC OVERLAY
EXISTING ASPHALT
MILL 1.5"
NOTES:
1. SUBGRADE PREPARATION TO BE IN ACCORDANCE
WITH GEOTECH REPORT.
APPROVED SUBGRADE BY
CONTRACTORS INDEPENDENT
TESTING AGENCY. SEE
GEOTECH REPORT.
APPROVED SUBGRADE BY
CONTRACTORS INDEPENDENT
TESTING AGENCY. SEE
GEOTECH REPORT.
SCALE:10
DRAIN BASIN DETAIL
NTS
NOTES:
1. SEE DETAIL 5/CS501 FOR PROFILE VIEW
EXISTING GUTTER
8" DRAIN BASIN
36"
8" HDPE
3" DEPTH DRAINAGE
AGGREGATE (SEE
DETAIL 10/CS501)
8" DRAIN BASIN (SEE
DETAIL 4/CS501)
GEOTEXTILE FABRIC
DRAINAGE AGGREGATE
AutoCAD SHX Text
GARY R JOHNSON
NUMBER PE-2012005390
ME 454.21
454.02
454.24
ME 454.43
454.12
ME 454.31
1.0
1.1
1.2%
0.6%
0.7%
1.0%
9'
9'
9' 1.0
0.6%
0.6%
CIVIL SITE DETAILS 2
CS502
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
JEFFERSON BARRACKS
NATIONAL CEMETERY
CORRECT FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
MARCH 28, 2024
852CM3042
Fi le
P at h:
c
:\u se rs \e br od m ar kl e\ de sk to p\ ne w lo go
\v as he et x4
2-ne w lo go -2
3.
dw eb ro dm ar kl d:
1/
/2
8:
lo t:1 /1
6/
:0
A M
CONSULTANTS
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314)-692-5195
03/28/2024
SCALE:5
STREET SECTION A-A'
NTS
EXISTING ROLL CURB
AND GUTTER NEW ROLL CURB AND GUTTER
(CONTRACT OPTION 1)
VARIES VARIES
A A'
SCALE:6
STREET SECTION B-B'
NTS
EXISTING ROLL
CURB AND GUTTER EXISTING ROLL CURB
AND GUTTERVARIES VARIES
B B'
SCALE:8
STREET SECTION C-C'
NTS
EXISTING ROLL
CURB AND GUTTER
VARIES VARIES
C C'
SCALE:9
STREET SECTION D-D'
NTS
EXISTING ROLL
CURB AND GUTTER
VARIES VARIES
D D'
EXISTING ROLL CURB
AND GUTTEREXISTING ROLL CURB
AND GUTTER
18' PARKING STALL
18' PARKING STALL
VARIES (ROADWAY)
18' PARKING STALL
VARIES (ROADWAY) VARIES (ROADWAY)
VARIES (ROADWAY)
FILL WITH JOINT SEALER
6"
1/2"
1/ 2"
5'
1/4" RADIUS, TYP.
Z Z
Z Z
CONTROL JOINT
CONSTRUCTION JOINT
PROVIDE CONTROL JOINTS PER SITE
PLAN CS401.
3/8" JOINT SEALER
CONFORMING TO
ASTM D 1850
PREMOULDED EXPANSION
JOINT FILLER CONFORMING
TO ASTM D1751 OR D1752
24" #4 DOWEL 18" O.C.,
FIXED ONE SIDE, SLIP
OTHER
APPROVED SUBGRADE BY CONTRACTORS INDEPENDENT TESTING AGENCY. SEE
GEOTECH REPORT.
4" OPEN GRADED ROCK (ASTM C33 SIZE NO. 57
AGGREGATE OR SIMILAR)
WOVEN GEOTEXTILE FABRIC
FLUSH W/ADJACENT PAVEMENT
6" JOINTED PCC-REINFORCED 5000 PSI. 6% AIR
ENTRAINED
NO. 4 REINFORCEMENT BARS 18" O.C. E.W.
NOTES:
1. EXTEND 6" AGGREGATE BASE 1' MINIMUM PAST CONCRETE EDGE IF CONCRETE IS
NOT ABUTTING EXISTING PAVEMENT OR STRUCTURES.
2. VERIFY CONCRETE AND BASE COURSE WITH GEOTECHNICAL REPORT AND
RECOMMENDATIONS.
EXISTING SUBGRADE
EX. ACC OR PPC PAVEMENT
SCALE:7
HEAVY DUTY CONCRETE PAVEMENT
NTS
ASPHALT TACK COAT AT ADJOINING ACC
PAVEMENT SECTION
PROVIDE 24" #4 DOWEL FIXED ONE SIDE SLIP
THE OTHER AT ADJOINING EXISTING PCC
PAVEMENT
2"
EXPANSION JOINT
EXPANSION JOINT FILLER
4" MoDOT TYPE 5
AGGREGATE BASE
6" JOINTED PCC-NON-REINFORCED
5000 PSI. 6% AIR ENTRAINED.
EXISTING SUBGRADE
SCALE:1
AC CONCRETE PAD DETAIL
NTS
EB SL
NOTES:
1. ALL GRADE BREAKS WITHIN THE PARKING STALL SHALL BE PERPENDICULAR TO THE PATH OF
TRAVEL.
2. ALL SLOPES ARE ABSOLUTE, RATHER THAN RELATIVE TO SIDEWALK/ROADWAY GRADES.
SCALE:2
HANDICAP STALL LAYOUT DETAIL
1"-10'
SIGN TO MEET STATE
AND A.D.A. CODES
18"
18"
18"
12"
36"
PAVEMENT SURFACE
4" DIA. STEEL PIPE W/
CONCRETE INFILL
SIGN POST
12"
SCALE:3
HANDICAP SIGN INSTALLATION DETAIL
NTS
4" DRAINTILE
1/4"
1-1/2"MIN.
EXISTING
STRUCTURE/
PAVEMENT
12"
12"
6"
SCALE:4
CONCRETE JOINTS
NTS
AutoCAD SHX Text
GARY R JOHNSON
AutoCAD SHX Text
NUMBER PE-2012005390
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
PERMIT
AutoCAD SHX Text
REQUIRED
AutoCAD SHX Text
UP TO $200 FINE
FOR VIOLATION
1 HOUR 1 HOUR
FE
1.5
DCBA
123 1.5
DCBA FE
123 1.5
AS 1
185 SF
OIL & PAINT
STORAGE
455 SF
PARTS &
EQUIP
STORAGE
276 SF
CARPENTRY96 SF
114A
OTHER
40 SF
TOILET
1738 SF
REPAIR
AREA
860 SF
WASH
805 SF
REPAIR
AREA
55 SF
PESTICIDE
AREA
347 SF
STORAGE
AS 1
AS 1
'-0
AS 2
AS 1
AS 1
GARAGE BAY GARAGE BAY GARAGE BAY GARAGE BAY
FOR WORK TO BE COMPLETED IN GARAGE BAYS, CONTRACTOR SHALL ALLOW TWO OF FOUR BAYS TO BE ACCESSIBLE BY STAFF AT ALL TIMES.
FOR WORK TO BE COMPLETED NORTH OF GARAGE BAYS (RESTROOM, DUCTWORK, ETC.) CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK WITH CEMETERY AND COR.
G A
R A
G E
B A
Y A
P P
R O
X .3
7' -4
A P
P R
O X
3' -0
1' -2
2'
-0
S E
E M
E C
H
1.5
C
FL ELEV
455'-6"
AS 1
ROOF MOUNTED
EXHAUST FAN FOR
TOILET ROOM,
SEE MECHANICAL
(2X) ROOF MOUNTED
EXHAUST FAN,
SEE MECHANICAL
REMOVE DUCT,
INFILL WITH CMU
AND FACE BRICK
TO MATCH EXIST,
SEE
PARTIAL
REMOVAL OF
WALL FOR DUCT
PENETRATION.
PROVIDE
FLASHING AND
SEALANT. SEE
MECHANICAL
'-8
S
E E
M E
C H
1' -2
/5 AS 2
FL ELEV
455'-6"
FLASHING
REGLET
WATERPROOFING
DRAIN TILE SEE 5/CS501
AS 2
AS 2
EXIST GUTTER AND
DOWNSPOUT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314)-692-5195
C U s e rs
\e m a rk fo rt
\D o c u m e n ts \1
-J
B N
C
F C
A
-A
E
M a rk fo rt
.r v t
/2
/2
:0
:4
P
M
3001-AS 1
GENERAL NOTES, FLOOR PLAN,
PARTIAL CEILING PLAN, DETAILS
JEFFERSON BARRACKS
NATIONAL CEMETERY CORRECT
FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
853CM3042
MARCH 28, 2024 JL EM
17550
1/8" = 1'-0"
OVERALL PLAN
_SHEET NOTES
1. ALL EXISTING CONDITIONS MUST BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO DEMOLITION OR CONSTRUCTION. EXISTING
CONDITIONS THAT DIFFER FROM THOSE SHOWN MUST BE BROUGHT TO
THE ATTENTION OF THE C.O.R. TO INFORM THE ARCHITECT AND
ENGINEERS.
2. THE INFORMATION SHOWN ON THE DRAWINGS IS BASED ON DRAWINGS
AND PHOTOGRAPHS PROVIDED BY THE GOVERNMENT COMBINED WITH
OBSERVATIONS AND SURVEYED DATA FROM THE ARCHITECTS AND
ENGINEERS.
3. SEE CIVIL, ELECTRICAL, AND VENTILATION DRAWINGS AND
SPECIFICATIONS FOR ADDITIONAL DEMOLITION AND CONSTRUCTION
REQUIREMENTS.
_DEMOLITION PLAN KEYED NOTES
DE1 TEMPORARILY REMOVE EARTH ADJACENT TO NORTH WALL AND PARTIAL
REMOVAL OF EARTH AT EAST AND WEST WALLS TO ACCESS DRAIN TILE
AND WATERPROOFING
DE2 SAW CUT REGLET ALONG EAST, NORTH, AND WEST EXISTING WALLS FOR
NEW WATERPROOFING TERMINATION AT MASONRY JOINT ABOVE GRADE
DE3 REMOVE DRAIN TILE AND PREPARE FOR REPLACEMENT DRAIN TILE
DE4 REMOVE EXIST WATERPROOFING. PREPARE FOR SELF ADHERING
WATERPROOFING
DE5 PREPARE EXIST WALL FOR FLASHING
DE6 PREPARE WALL FOR INFILL AT REMOVED DUCTWORK, MATCH EXIST
DE7 PARTIAL ROOF REMOVAL FOR MECHANICAL EXHAUST, SEE MECHANICAL
DE8 REMOVE EXISTING CEILING IN RESTROOM, REMOVE ELECTRICAL AND
MECHANICAL COMPONENTS, SALVAGE SYSTEMS FOR REUSE AS
INDICATED BY ELECTRICAL AND MECHANICAL
DE9 PARTIAL REMOVAL OF WALL FOR DUCT PENTRATION, SEE MECHANICAL
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
DE1
DE2
DE3
DE4
DE5
FL1
FL2
FL3
FL4
FL5
DE6 FL6
DE6 FL6
FL7FL7 DE8
1/4" = 1'-0"
PARTIAL REFLECTED CEILING PLAN
0 8' 16'4'
0 4' 8'2'
RC1
RC2
RC3
1/8" = 1'-0"
EXIST EAST ELEVATION
1/8" = 1'-0"
EXIST SOUTH ELEVATION
0 8' 16'4'
0 8' 16'4' 1/8" = 1'-0"
BUILDING SECTION
1/2" = 1'-0"
WALL SECTION
0 2' 4'1'
_REFLECTED CEILING PLAN KEYED NOTES
RC1 ACT CEILING SYSTEM, MATCH EXIST HEIGHT. BASIS OF DESIGN
ARMSTRONG, CIRRUS ANGLED TEGULAR 5/16 #584, WHITE, 24"X48" WITH
GRID PRELUDE XL 15/16"
RC2 LED LIGHTING, SEE ELECTRICAL
RC3 EXHAUST FAN, SEE MECHANICAL
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_ROOF PLAN KEYED NOTES
RO1 INSTALL EXHAUST FAN, SEE MECHANICAL. CONSTRUCT CRICKETS,
PATCH AND REPAIR ROOF AS REQUIRED
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
_FLOOR PLAN KEYED NOTES
FL1 REPLACE EARTH TO MATCH EXIST CONDITIONS. ENSURE EARTH SLOPES
DOWN AND AWAY FROM BUILDING. SEE CIVIL DRAWINGS
FL2 CONSTRUCT REGLET IN ACCORDANCE WITH WATERPROOFING
MANUFACTURER INSTRUCTIONS. SEE 4/AS 2
FL3 DRAIN TILE AT FOOTING. COORDINATE WITH CIVIL
FL4 APPLY WATERPROOFING FROM REGLET TO FOOTING DRAIN TILE
FL5 FLASHING UNDER SOFFIT AT TOP OF MASONRY. SEE 6/AS 2
FL6 INFILL WALL, MATCH EXIST. SEE 5/AS 2
FL7 PATCH AND REPAIR WALL AT MODIFIED DUCT
FL8 PREPARE WALL OPENING WITH FLASHING AND SEALANT FOR DUCT
PENETRATION. SEE MECHANICAL.
FL9 ELECTRICAL PANELS, SEE ELECTRICAL
NOTE: NOT ALL KEYED NOTES MAY BE USED ON EACH PLAN
PHOTO NORTHEAST CORNER:
EXIST CONDITIONS WITH POSSIBLE
REGLET LOCATIONS
PHOTO WEST ELEVATION:
EXIST CONDITIONS WITH POSSIBLE
REGLET LOCATIONS
FL2 FL2
0 8' 16'4'
DE9 FL8
FL9
Revisions: Date:
1 2 31.5
1 HOUR 1 HOUR
FE
1.5
DCBA
AS 1
1.5
A B C D E F
DE7
DE7 DE7
RO1
RO1 RO1
3"
/ 1 2"
E X
IS
T
S
LO
P E
D N
E X
IS
T
S
LO
P E
D N
EXIST GUTTER 6"X6"EXIST DOWNSPOUT 5"X5" EXIST DOWNSPOUT 5"X5"
EXIST DOWNSPOUT 5"X5" EXIST GUTTER 6"x6"
EXIST MECHANICAL UNIT
3" / 1'-0"
EXIST SLOPE
DN 3" / 1'-0"
E X
IS
T
S
LO
P E
D N
3"
1' -0
E X
IS
T
S
LO
P E
D N
3"
1' -0
EXIST SLOPE
DN
EXIST
SLOPE
DN
REMOVE WOOD
INFILL, INFILL
WITH CMU AND
FACE BRICK TO
MATCH EXIST
REPLACE LOUVER
AS SPECIFIED
EXIST PIPE, TO
REMAIN
FL2
185 SF
OIL & PAINT
STORAGE
455 SF
PARTS &
EQUIP
STORAGE
276 SF
CARPENTRY96 SF
114A
OTHER
40 SF
TOILET
1738 SF
REPAIR
AREA
860 SF
WASH
805 SF
REPAIR
AREA
55 SF
PESTICIDE
AREA
347 SF
STORAGE
TRAVEL D
ISTANCE
'-1
0"
DIAGONAL D
IS
TANCE
99'-1 0"
VERIFY IN FIELD
81'-9", EXIST
FE
FE
FE
E X
IT
E X
IT
LIFE SAFETY SYMBOLS
1 HOUR FIRE
BARRIER
TRAVEL DISTANCE
100'-10"
TRAVEL DISTANCE
EXIT EXIT LIMITS OF
CONSTRUCTION
FIRE
EXTINGUISHER
FE
FIRE
EXTINGUISHER
CABINET
FEC
HAZARDOUS USE
ADJACENT SYMBOLS SHOW PARTITION RATING.
OPENINGS REQUIRE CLOSER & LATCH
NOTE: NOT ALL SYMBOLS MY BE USED ON EACH PLAN
APPLICABLE REGULATIONS
2024 NFPA 101 (LIFE SAFETY CODE)
ABA STANDARDS (2015) (ABAAS)
2021 IBC
VA PHYSICAL SECURITY AND RESILIENCE DESIGN MANUAL (PSRDM)
NFPA NATIONAL FIRE CODES (EXCEPTION: NFPA 5000 & 900)
OSHA STANDARDS
NATIONAL ELECTRIC CODE (NEC)
ASME CODE FOR PRESSURE PIPING
BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE,
AMERICAN CONCRETE INSTITUTE AND COMETARY (ACI 318)
MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE
FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL STEEL
BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
ENERGY POLICY ACT OF 2005 (EPAct)
DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS
FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE
RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL
BUILDINGS, 10 CFR PARTS 433,434 AND 435
FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE
BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
EXECUTIVE ORDER 13834
THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED
IN THE GENERAL REQUIREMENTS SECTION 01010 OF THE VA
MASTER CONSTRUCTION SPECIFICATION
VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE
STANDARD 62.1-2004
SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE
STANDARD 15 -2007
VA FIRE PROTECTION DESIGN MANUAL
VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA
NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER
GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL)
AREA SEPARATIONS / FIRE WALLS
TYPE(S) OF CONSTRUCTION - NO CHANGE
CONSTRUCTION TYPE(S)
SEE LIFE SAFETY PLANS
TYPE V [000] (NFPA 220 TABLE 4.1.1)
NOYESGENERAL TYPE OF PROJECT
REMODEL
ADDITION
NEW BUILDING
PROJECT DESCRIPTION
CODE SUMMARY
Provide repairs to Existing Maintenance Building at National Cemetery.
No changes to Areas, Heights, Occupant Load, Plumbing Fixtures, or Fire Resistive Requirements.
NOYESAUTHORITIES HAVING JURISDICTION (AHJ's)
THE JOINT COMMISSION (JC)
U.S. DEPARTMENT OF VETERANS AFFAIRS (VA)
NOYES
(Section 8.3)
CHANGE OF OCCUPANCY?
SEPARATED OCCUPANCIES?
FIRE BARRIER RATING(S) SEE LIFE SAFETY PLANS
OCCUPANCY CLASSIFICATION - NO CHANGE
OCCUPANCIES
(If Remodeling)
2024 LSC (TABLE 6.1.14.1)
SPECIAL PURPOSE INDUSTRIAL
TESTRATING (HRS)
OTHER
ROOF CONSTRUCTION
PRIME & SEC. FLOOR BEAMS, JOISTS
FLOOR/CEILING ASSEMBLY
FLOOR CONSTRUCTION
INTERIOR
NON-BEARING WALLS AND PARTITIONS
BEARING WALLS
COLUMNS
GIRDERS
TRUSSES
ROOF/CEILING ASSEMBLY
PRIME & SEC. ROOF BEAMS, JOISTS
EXTERIOR
INTERIOR BEARING WALLS
EXTERIOR BEARING WALLS
STRUCTURAL FRAME
FIRE-RESISTIVE REQUIREMENTS - NO CHANGE
ZERO/ 1-HR
ZERO
ZERO NA
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZERO
ZEROEXTERIOR DOORS AND WINDOWS
NA
NA
NA
NA
NA
U901
NA
NA
NA
NA
NA
KERF CUT INTO EXISTING BRICK
SEALANT
PREFINISHED REMOVABLE
BREAK METAL FLASHING
PREFINISHED BREAK METAL FLASHING
WATERPROOFING
PREFINISHED BREAK METAL
REGLET
GRADE
EXISTING WALL
CONSTRUCTION
8" M
IN
EXISTING WALL
CONSTRUCTION
4" FACEBRICK TO
MATCH EXIST
AS SCHEDULED, PAINT
FINISH, CORNER TO
CORNER
MASONRY TO
MATCH EXIST
AS SCHEDULED,
PAINT FINISH,
CORNER TO
CORNER
RATED CONSTRUCTION:
U901
SOUND TRANSMISSION CLASS:
44-49
SEALANT
PREFINISHED
METAL
FLASHING
EXISTING WALL
CONSTRUCTION
1/2"
SEALANT
EXISTING
BREAK METAL &
CLOSURE ANGLE
GARAGE BAY GARAGE BAY GARAGE BAY
FOR WORK TO BE COMPLETED IN GARAGE BAYS, CONTRACTOR SHALL ALLOW TWO OF FOUR BAYS TO BE ACCESSIBLE BY STAFF AT ALL TIMES.
FOR WORK TO BE COMPLETED NORTH OF GARAGE BAYS (RESTROOM, DUCTWORK, ETC.) CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK WITH CEMETERY AND COR.
G A
R A
G E
B A
Y A
P P
R O
X .3
7' -4
PAINT PAINT
P A
IN
T
P A
IN
T
P A
IN
T
P A
IN
T
185 SF
OIL & PAINT
STORAGE
455 SF
PARTS &
EQUIP
STORAGE
276 SF
CARPENTRY96 SF
114A
OTHER
40 SF
TOILET
1738 SF
REPAIR
AREA
860 SF
WASH
805 SF
REPAIR
AREA
55 SF
PESTICIDE
AREA
347 SF
STORAGE
GARAGE BAY
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314)-692-5195
C U s e rs
\e m a rk fo rt
\D o c u m e n ts \1
-J
B N
C
F C
A
-A
E
M a rk fo rt
.r v t
/2
/2
:0
:4
P
M
3001-AS 2
LIFE SAFETY PLAN, FINISH
SCHEDULE, ROOF PLAN, DETAILS
JEFFERSON BARRACKS
NATIONAL CEMETERY CORRECT
FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
853CM3042
MARCH 28, 2024 JL EM
17550
0 8' 16'4'1/8" = 1'-0"
ROOF PLAN
1/8" = 1'-0"
WEST ELEVATION
0 8' 16'4'
1/16" = 1'-0"
LIFE SAFETY PLAN
0 8' 16'4'
ROOM USE AREAS
Number Name Area
112 STORAGE 347 SF
113 CARPENTRY 276 SF
114 TOILET 40 SF
114A OTHER 96 SF
115 PARTS & EQUIP STORAGE 455 SF
116 OIL & PAINT STORAGE 185 SF
117 REPAIR AREA 1738 SF
118 WASH 860 SF
119 REPAIR AREA 805 SF
120 PESTICIDE AREA 55 SF
4856 SF
ROOM FINISH SCHEDULE
NO. NAME
WALL FINISH
FLOOR FINISH CEILING FINISH CEILING HEIGHT REMARKSNORTH EAST SOUTH WEST
112 STORAGE EXIST EXIST EXIST PAINT EXIST EXIST VARIES
113 CARPENTRY EXIST PAINT EXIST PAINT EXIST EXIST VARIES
114 TOILET EXIST EXIST EXIST EXIST EXIST ACT 9'-4" CEILING SHALL BE APPROXIMATELY AT THE SAME
HEIGHT AS EXISTING TO MAINTAIN FIRE ALARM
COMPONENT LOCATIONS
114A OTHER EXIST EXIST EXIST EXIST EXIST EXIST VARIES
115 PARTS & EQUIP STORAGE EXIST EXIST EXIST EXIST EXIST EXIST VARIES
116 OIL & PAINT STORAGE EXIST EXIST EXIST EXIST EXIST EXIST VARIES
117 REPAIR AREA PAINT EXIST EXIST EXIST EXIST EXIST VARIES
118 WASH PAINT EXIST EXIST EXIST EXIST EXIST VARIES
119 REPAIR AREA EXIST EXIST EXIST EXIST EXIST EXIST VARIES
120 PESTICIDE AREA EXIST EXIST EXIST EXIST EXIST EXIST VARIES
1 1/2" = 1'-0"
DETAIL - REGLET @ EXISTING BRICK
1 1/2" = 1'-0"
DETAIL - INFILL @ EXISTING BRICK
1 1/2" = 1'-0"
DETAIL - FLASHING @ EXISTING BRICK
1/8" = 1'-0"
FINISH PLAN
0 8' 16'4'
MTR
R
DSD
H
O
AI
AO
DI
DO
FS
FM
H
H
C
C
C
C
T
T
T
T
S
DIRECTION OF AIR FLOW
FLEXIBLE DUCT
MANUAL VOLUME DAMPER
RISE IN DIRECTION OF AIR FLOWR
DUCT CAP
DROP IN DIRECTION OF AIR FLOWD
DUCT DOWN
DUCT UP
SUPPLY/OUTSIDE AIR DUCT SECTION
RETURN AIR DUCT SECTION
EXHAUST/RELIEF AIR DUCT SECTION
4-WAY DIFFUSER WITH BLANKOFF IN ONE DIRECTION
SD-1
6/115
AIR TERMINAL PROPERTIES SYMBOL
NECK SIZE/CFM
TERMINAL AIR BOX (REFER TO SCHEDULE)###
### TERMINAL AIR BOX w/REHEAT COIL (REFER TO SCHEDULE)
HUMIDIFIERH
OPPOSED BLADE DAMPER (REFER TO SCHEDULE)
PARALLEL BLADE DAMPER (REFER TO SCHEDULE)
DIFFERENTIAL PRESSURE SENSOR
CARBON MONOXIDE SENSORC
CARBON DIOXIDE SENSORC2
HUMIDISTAT SENSORH
HUMIDISTAT/SENSOR (DUCT MOUNTED)H
OCCUPANCY SENSORO
PRESSURE SENSOR/MONITORP
PRESSURE SENSOR (DUCT MOUNTED)P
THERMOSTAT/SENSORT
TEMPERATURE SENSOR (DUCT MOUNTED)T
THERMOSTAT/SENSOR WITH HEAVY DUTY ENCLOSURET
VENTILATION SYMBOL LIST
SYMBOL: DESCRIPTION:
AIRFLOW MEASUREMENT SYMBOL
XX - DOAS SYMBOL
Y - SEQUENTIAL NUMBER
XX-Y
NOT ALL SYMBOLS MAY APPLY.
FAN POWERED TERMINAL AIR BOX w/REHEAT COIL (REFER TO
SCHEDULE)
VENTILATION ABBREVIATION KEY
ABBR: DESCRIPTION:
DIFFERENTIAL PRESSURE GAUGE (RANGE)DPG (0-2")
DIFFERENTIAL PRESSURE SWITCHDPS
AD ACCESS DOOR
ABOVE FINISHED FLOORAFF
CFSD CONTROL/FIRE/SMOKE DAMPER
EA EXHAUST/RELIEF AIR
FD FIRE DAMPER
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FSD FIRE/SMOKE DAMPER
MA MIXED AIR
OA OUTSIDE AIR
RA RETURN AIR
SA SUPPLY AIR
SD SMOKE DAMPER
TRANSFER DUCTTD
UC-1 DOOR UNDERCUT BY OTHERS (1" TYPICAL)
ECFSD EXISTING CONTROL FIRE SMOKE DAMPER
EFD EXISTING FIRE DAMPER
EFSD EXISTING FIRE SMOKE DAMPER
ESD EXISTING SMOKE DAMPER
TERMINAL AIR BOXTAB
TYPICALTYP
UON UNLESS OTHERWISE NOTED
N.C. NORMALLY CLOSED
NOT IN CONTRACTNIC
NORMALLY OPENN.O.
SCCR SHORT CIRCUIT CURRENT RATING
DCE DUST COLLECTION EXHAUST
MAU MAKEUP AIR
CO CLEANOUT
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
SIMSIM
INDICATES SIMILAR DETAIL REFERENCED IN
MULTIPLE LOCATIONS
LEVEL NAME
10' - 0" HEIGHT ABOVE
PROJECT 0' - 0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT WORK
REQUIRED, SPECIFIC TO THE SHEET AND/OR
DETAIL
N O R
HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
LINE TYPE AND TAG KEY:
NEW WORK BY THIS CONTRACTOR (WIDE LINE)
NEW
EXISTING TO BE REMOVED (SHORT DASHED PATTERN)
NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)
EXISTING
EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)
EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
HALFTONING DOES NOT MODIFY SCOPE.
'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING
TAG-1 UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL
INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST
INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL
T101
THE LINE TYPES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY RATINGS WITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL MATERIALS REQUIRED TO COMPLY
WITH THOSE RATINGS WHETHER SHOWN OR NOT.
FIRE / SMOKE BARRIER DESIGNATIONS
1 HOUR FIRE BARRIER
SMOKE BARRIER
1 HOUR FIRE/SMOKE BARRIER OR
SHAFT ENCLOSURE
2 HOUR FIRE/SMOKE BARRIER OR
SHAFT ENCLOSURE
3 HOUR FIRE/SMOKE BARRIER
4 HOUR FIRE/SMOKE BARRIER
SMOKE PARTITION
FIRE PARTITION
2 HOUR FIRE BARRIER OR WALL
3 HOUR FIRE BARRIER OR WALL
4 HOUR FIRE BARRIER OR WALL
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED TO, FIRE
PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS. DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC., AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES.
BRING ANY INTERFERENCES OR CONFLICTS TO THE ATTENTION OF THE COR BEFORE PROCEEDING WITH
FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE REASONABLE
ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER ACCESS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO COORDINATE SHALL
BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR EXPENSE TO THE GOVERNMENT.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL CHANGES REQUIRED
FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF DESIGN.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL AND OTHER MECHANICAL PLANS FOR
EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES, OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH
ORIGINAL CONSTRUCTION, FIRE RATING, AND FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE PANEL TYPE AND COLOR. NOTIFY THE
GC OF THE REQUIRED ACCESS PANELS PRIOR TO BIDDING.
10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING, AND DUCTS PENETRATE. PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH
WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION, FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO ANOTHER
AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS.
12. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT MANUFACTURERS.
CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND REQUIRED SERVICE CLEARANCES.
COORDINATE WITH LAYOUT OF EQUIPMENT PADS, PIPING, DUCTWORK, ETC.
13. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES.
14. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR STARTERS, SWITCHES, AND DISCONNECTS.
15. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL EXTEND MINIMUM 6”
BEYOND ALL SIDES OF EQUIPMENT.
16. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER NON-STRUCTURAL
BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE CRACKED CONCRETE APPROVED IN
ACCORDANCE WITH SPECIFICATIONS.
MECHANICAL RENOVATION NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED TO, FIRE
PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND REPORT ANY CONFLICTS BEFORE
PROCEEDING.
2. NOT ALL EXISTING DUCTWORK AND PIPING IS SHOWN. VERIFY EXISTING CONDITIONS BEFORE STARTING
WORK. NOTIFY COR OF ANY CONFLICTS WITH NEW WORK.
3. EACH CONTRACTOR SHALL FIELD VERIFY ACCESSIBILITY TO THE AREA OF HIS/HER WORK AND SHALL NOTIFY THE GENERAL CONTRACTOR PRIOR TO BIDDING IF OTHER UTILITIES ARE REQUIRED TO BE REMOVED OR
RELOCATED TO ALLOW ACCESS TO HIS/HER AREA OF WORK.
4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF ROOFS, WALLS, AND FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS. CONTRACTORS SHALL NOTIFY THE GC OF
AFFECTED AREAS PRIOR TO BIDDING.
5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL CONTRACTORS. NOTIFY THE GENERAL
CONTRACTOR OF AFFECTED AREAS PRIOR TO BIDDING.
6. WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER ARRANGE NEW EQUIPMENT, PIPING, OR DUCTWORK IN SUCH A FASHION THAT IT DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING MECHANICAL SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR
DUCTWORK.
7. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION.
MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONS THAT REMAIN ACTIVE.
8. OBTAIN PERMISSION FROM COR BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY REASON. MAINTAIN SERVICE
TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL NEW SYSTEMS ARE INSTALLED.
9. MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR TIE IN AND SWITCHOVER. DRAIN SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. OBTAIN PERMISSION FROM COR BEFORE PARTIALLY OR COMPLETELY DRAINING SYSTEM. MAKE CHANGEOVER TO NEW SYSTEMS WITH
MINIMUM OUTAGE.
10. DISCONNECT AND REMOVE MECHANICAL DEVICES AND EQUIPMENT SERVING EQUIPMENT THAT HAS BEEN
REMOVED.
1. UNLESS NOTED OTHERWISE, THE SIZE OF EACH BRANCH DUCT TO A TERMINAL AIR BOX (TAB) SHALL MATCH THE INLET SIZE UNLESS THE BRANCH IS GREATER THAN 6FEET IN LENGTH, IN WHICH CASE THE BRANCH DUCT
SHALL BE SIZED AT A PRESSURE DROP OF 0.07"W.C. PER 100' OF DUCTWORK.
2. UNLESS NOTED OTHERWISE, THE SIZE OF EACH BRANCH DUCT TO AN AIR TERMINAL SHALL MATCH THE INLET
SIZE.
3. PROVIDE ACCESS DOORS AT ALL DUCT MOUNTED EQUIPMENT.
VENTILATION GENERAL NOTES:
TEMPERATURE CONTROLS ABBREVIATION KEY
ABBR: DESCRIPTION:
MIXING VALVEMV
N.C. NORMALLY CLOSED
NOT IN CONTRACTNIC
NORMALLY OPENN.O.
TYPICAL TYP
UNLESS OTHERWISE NOTESUON
MA MIXED AIR
OA OUTSIDE AIR
RA RETURN AIR
SA SUPPLY AIR
EXHAUST/RELIEF AIREA
FAN
MOTOR
CONTACTOR
PUMP
HUMIDIFIER
DUCT SMOKE DETECTOR
ACT
DS
DP
CS
VS
ANALOG INPUT
ANALOG OUTPUT
DIGITAL OUTPUT
HEATING/ COOLING COIL
FILTER
AIR BLENDER
OPPOSED BLADE DAMPER
PARALLEL BLADE DAMPER
TERMINAL AIR BOX
TERMINAL AIR BOX W/ REHEAT
NORMAL CLOSED CONTACT
NORMALLY OPEN CONTACT
MANUAL MOTOR STARTER
W/THERMAL OVERLOAD
CONTROL SYMBOL LIST
SYMBOL: DESCRIPTION:
NOT ALL SYMBOLS MAY APPLY.
OCCUPANCY SENSOR
ACTUATOR
DOOR SWITCH
DIFFERENTIAL PRESSURE SWITCH
CURRENT SWITCH
VIBRATION SWITCH
SENSOR
AIR FLOW SWITCH
DUCT FLOW METER
FLOW METER
FM
FLOW SWITCH
F
FS FLOW SENSOR
HUMIDITY SENSOR
(DUCT MOUNTED)
H
HUMIDISTAT SENSOR
HUMIDISTAT / SENSOR
CARBON MONOXIDE SENSOR
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR (DUCT
MOUNTED)
CARBON DIOXIDE SENSOR (DUCT
MOUNTED)
STATIC SWITCH
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P
DIFFERENTIAL PRESSURE SENSOR
PRESSURE SENSOR (FURNISHED WITH BALL VALVE)P
P PRESSURE SENSOR (DUCT MOUNTED)
SP
T
THERMOSTAT
TEMPERATURE SENSOR (DUCT MOUNTED)
THERMOSTAT/SENSOR WITH HEAVY DUTY ENCLOSURET
TEMPERATURE SENSOR WITH WELL
T
THERMOMETER WITH WELL (DIAL TYPE)T
THERMOMETER WITH WELL (FILLED TYPE)
AVERAGING TEMPERATURE SENSOR
PROBE TEMPERATURE SENSOR
LOW LIMIT TEMPERATURE
SWITCH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314)-692-5195
C U s e rs
\k fi n c k \D o c u m e n ts \1
-J B
N C
F
C A
-M k fi n c k C
D K
.r v t
/2
/2
:2
:0
A
M
3001-MV000
VENTILATION COVERSHEET JEFFERSON BARRACKS
NATIONAL CEMETERY CORRECT
FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
853CM3042
03/28/2024
KTH RWB
17550
VENTILATION SHEET INDEX
3001-MV000 VENTILATION COVERSHEET
3001-MV111 VENTILATION FLOOR PLAN
3001-MV401 VENTILATION, CONTROL DIAGRAMS & DETAILS
GRAND TOTAL: 3
1.5
DCBA
3001-MV401
6ø
6ø
6ø 6ø
6ø
14x14
6ø
18x18
10ø x
3001-MV401
CONNECT NEW 14"x14"
EXHAUST DUCT TO EXISTING
14"x14" EXHAUST DUCT
REMOVE EXISTING EXHAUST DUCT
SHOWN DASHED
EF-1
REMOVE EXISTING OUTDOOR AIR
LOUVER AND EXHAUST DUCTWORK
PROVIDE BACKDRAFT DAMPER
WITH 48"x30" OUTDOOR AIR LOUVER.
REUSE EXISTING OPENING.
14" DIA. EXHAUST
DUCT TO EF-42.
REMOVE EXISTING
DUCTWORK SHOWN DASHED
ROUTE NEW EXHAUST DUCT UP THRU ROOF & FLASH ROOF
PENETRATION. TERMINATE WITH GOOSENECK &
BACKDRAFT DAMPER AT ROOFLINE. SEE DRAWING 3/MV-401.
C
CARBON MONOXIDE SENSOR/
DETECTOR FOR EF-1
EF-2
EF-28
REMOVE EXISTING
DUCTWORK SHOWN DASHED
REMOVE EXISTING
DUCTWORK SHOWN DASHED
3001-MV401
12x1220x20
NEW 12"x12" EXHAUST DUCT CUT AT
45 DEGREES, COVER OPENING WITH
1/4" WIRE MESH.
14x16
EF-42
14"x14" EXHAUST UP THRU ROOF & FLASH ROOF
PENETRATION. SEE DRAWING 4/MV401 FOR
EXHAUST HOOD DETAIL (ON ROOF).
MOUNT EF-42 PER MANUFACTURERS
RECOMMENDATIONS
6" EXHAUST UP THRU ROOF. SEE DRAWING
4/MV401 FOR EXHAUST HOOD DETAIL (ON ROOF).
SUPPORT EF-28 PER
MANUFACTURERS
RECOMMENDATIONS
SERVICE CLEARANCE
CONTRACTOR TO DEMO
DUCT AND PATCH WALL TO
MATCH EXISTING
CONTRACTOR TO DEMO EXISTING EXHAUST
FAN AND PATCH CEILING TO MATCH EXISTING
S
EF-1 OVER RIDE SWITCH
S
EF-42 SWITCH
S
EF-28 SWITCH
SCALE: 3/16" - 1'-0"
CONNECT NEW 14"x14"
EXHAUST DUCT TO EXISTING
14"x14" EXHAUST DUCT
BALANCE TO
600 CFM
BALANCE TO 1,000 CFM
BALANCE TO 1,000 CFM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314)-692-5195
C U s e rs
\k fi n c k \D o c u m e n ts \1
-J B
N C
F
C A
-M k fi n c k C
D K
.r v t
/2
/2
:2
:0
A
M
3001-MV111
VENTILATION FLOOR PLAN JEFFERSON BARRACKS
NATIONAL CEMETERY CORRECT
FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
853CM3042
03/28/2024
KTH RWB
17550
GENERAL NOTES:
1. MECHANICAL CONTRACTOR SHALL FIELD VERIFY
LOCATIONS OF EXISTING EQUIPMENT AND NEW
EQUIPMENT LOCATIONS PRIOR TO ROUGH-IN.
CONTRACTOR SHALL OBTAIN APPROVAL OF LAYOUTS
AND LOCTIONS FROM THE ARCHITECT / OWNER. ANY
LOCATION IN WHICH THE ARCHITECT DEEMS ARE NOT
COORDINATED SHALL BE REWORKED BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
2. MECHANICAL CONTRACTOR SHALL FABRICATE NEW
DUCTWORK PER SMACNA. ALL DUCTWORK TO BE
DESIGNED AT MEDIUM PRESSURE PER ASHRAE.
3. MECHANICAL CONTRACTOR TO COORDINATE HVAC
CONTROLS TO BE DETERMINED DURING DETAIL DESIGN.
4. EXHAUST DUCTWORK BASED ON .1 1N. W.C./100FT TO
SIZE EXHAUST DUCT VELOCITY.
KEYNOTES:
1. CONTRACTOR TO DEMO EXISTING AXIAL FAN. REPLACE
IN KIND PER DETAIL DESIGN DRAWINGS.
2. CONTRACTOR TO DEMO EXISTING RESTROOM EXHAUST
FAN AND ASSOCIATED DUCTWORK. REPLACE IN KIND
PER DETAIL DESIGN DRAWINGS.
3. INSTALL NEW 3-DROP PLYMOVENT SYSTEM TO INCLUDE
ONE ROOF PENETRATION. SINGLE FAN UNIT (FAN-42) AT
1500 TO 1650 CFM.
4. INSTALL NEW SINGLE DROP PLYMOVENT SYSTEM TO
INCLUDE ONE ROOF PENETRATION. SINGLE FAN UNIT
(FAN-28) AT 500 TO 550 CFM.
5. CONTRACTOR TO DISCONNECT AND STORE
CONDENSING UNIT DURING EXCAVATION. INCLUDES
CAPTURING REFRIGERANT, DISCONNECTING AND
LOCKING-OUT ELECTRICAL. CONTRACTOR TO REINSTALL
AND REFILL REFRIGERANT AFTER EXCAVATION,
RECONNECT ELECTRICAL AND VERIFY OPERATION.
FIRST LEVEL PLAN - VENTILATION
N O R
HT
ALL SELECTIONS ARE BASED ON AN ALTITUDE OF 0 FEET.
NOTE
EF-28 SHOP
PLYMOVENT
FAN-28
VEHICLE
EXHAUST
550 INLINE CENTRIFUGAL DIRECT 1 120 3400 1 0,75 6.3 - 10.0A SEE DRAWING 4/MV-111
EF-42 SHOP
PLYMOVENT
FAN-42
VEHICLE
EXHAUST
1650 UTILITY DIRECT 3 208 3400 2 1,5 2.5 - 4.0A SEE DRAWING 3/MV-111 EC MOTOR, PROVIDE CURB AND ATTACHMENTS. SEE DRAWING 1/MV401
EF-2
RESTROOM ABOVE
CEILING
GREENHECK
SP-AP0511W-1
TOILET
EXHAUST
80 TOILET FAN EC 1 120 817 - SEE DRAWING 2/MV-111
EF-1 SHOP
GREENHECK
SQ-160
PURGE
EXHAUST
3000 INLINE DIRECT 1 120 1200 1/2 - SEE DRAWING 1/MV-111 ADD VFD FOR RAMPING
CFM
TYPE DRIVE PHASE VOLT RPM
HP KW MOTOR PROTECTION
SWITCH (MPS)
MARK LOCATION
MANUFACTURER
/MODEL
SYSTEM
AND/OR
SERVICE
AIR FLOW
FAN
CONTROL SEQUENCE REMARKS
FAN SCHEDULE
NOTE 3
WOOD NAILING STRIP
ROOF CURB, WITH 12" MINIMUM
HEIGHT REQUIREMENT
COORDINATE SLOPE WITH
ARCHITECT/ROOFER
NOTE 2
NOTE 1
CURB CAP
ROOF
GRAVITY BACKDRAFT DAMPER
(EXHAUST ONLY, WHERE NOTED)
DUCT (SIZE AND
ROUTE PER PLANS)
NOTE:
1.
2.
3.
SECURE HOOD TO WOOD NAILING STRIP WITH 3/8" CADMIUM PLATED LAG BOLTS
NOT OVER 12" ON CENTER.
SECURE ROOF CURB, DUCTWORK AND DAMPER TO ROOF RUST RESISTANT BOLTS
(METAL DECK & BAR JOIST ROOF).
FACTORY ASSEMBLED HINGED HOOD WITH LATCH AND BIRD SCREEN LOREN COOK
PR OR EQUAL. THE SPUN ALUMINUM STRUCTURAL COMPONENTS SHALL BE
CONSTRUCTED OF MINIMUM 16 GAUGE MARINE ALLOY ALUMINUM BOLTED TO A
RIGID ALUMINUM SUPPORT STRUCTURE.
TRANSITION DUCT TO
FULL SIZE OF DAMPER
SUPPLIED WITH HOOD
NOTE 2
C S
DO
DI
FM
AI
FM
AI
AO
FM
AI
DO
DI
FM
AI
AO
LEVEL 01
0"
LEVEL 02
14'-0"
LEVEL 03
27'-1 1/2"
MHR-850
6ø
FLOOR
ROOFLINE
CEILING
EF-42 EXHAUST HOOD.
SEE DETAIL 4/MV401
EXHAUST FAN
EF-42
" EF-42 EXHAUST FAN
CURB WITH FLASHING.
12" MINIMUM HEIGHT
SEE DETAIL 4/MV401
14/14 EA
14" DIA. EA
ROUTE DRAIN LINE TO
NEAREST FLOOR DRAIN
LEVEL 01
0"
LEVEL 02
14'-0"
EF-1
20x20 20x20
FLOOR
SERVICE CLEARANCE
SERVICE CLEARANCE
REMOVE EXISTING
EXHAUST DUCTWORK
SHOWN DASHED
CONNECT 20x20 EXHAUST
DUCTWORK TO EXHAUST
LOUVER
LEVEL 01
0"
LEVEL 02
14'-0"
EF-2
PROVIDE BACKDRAFT
DAMPER AT ROOFLINE
FLOOR
RESTROOM
CEILING
PROVIDE GOOSENECK
OPENING 36" MINIMUM
ABOVE ROOF WITH
1/4" MESH COVER
OVER OPENING
REMOVE EXISTING EXHAUST
DUCTWORK AND GRILLE
SHOWN DASHED. PATCH
CEILING OPENING TO
MATCH EXISTING.
FAN ON/OFF
INTERLOCKED WITH
CARBON MONOXIDE
SENSOR/DETECTOR.
EXHAUST
ZONE AIR
SEQUENCE OF OPERATION (EF-1):
1) EXHAUST FAN SHALL INTERLOCK WITH CARBON MONOXIDE
SENSOR/DETECTOR.
2) WHEN THE CARBON MONOXIDE SENSOR/DETECTOR TRIPS - THE
EXHAUST FAN WILL START. ONCE THE CARBON MONOXIDE SENSOR
IS SATIFIED THE EXHAUST FAN WILL RAMP DOWN AND RUN FOR 15
MIN AND SHUT OFF.
3) HAND/ON/OFF/AUTO SWITCH IN CASE SOMEONE WANTS TO TURN
ON AND THERE IS NO CO.
ALARMS, INTERLOCKS AND SAFETIES:
NA
EXTERIOR
FAN ON/OFF
INTERLOCKED WITH
LIGHT SWITCH AND
TIMER
BATHROOM
ZONE AIR
SEQUENCE OF OPERATION (EF-2):
1) THE FAN SHALL RUN DURING OCCUPIED HOURS.
2) EXHAUST FAN SHALL INTERLOCK WITH BATHROOM FAN LIGHTS.
WHEN THE LIGHTS ARE TURNED ON THE EXHAUST FAN WILL START.
WHEN THE LIGHTS ARE TURNED OFF THE EXHAUST FAN WILL RUN
FOR 15 MIN AND SHUT OFF.
ALARMS, INTERLOCKS AND SAFETIES:
NA
FAN
STATUS
CS
START/
STOP
ACT
SEQUENCE OF OPERATION:
1) WHEN HOSE REEL COLLECTION UNIT IS ENABLED MOTOR OPERATED DAMPER
SHALL OPEN AND MODULATE TO MAINTAIN AIRFLOW SETPOINT CFM (ADJ.).
EXHAUST AIRFLOW SETPOINT FROM BUILDING SHALL REMAIN.
2) 2-POSITION DAMPER SHALL FULLY OPEN WHEN FAN IS ENERGIZED. WHEN FAN IS
DE-ENERGIZED, 2-POSITION DAMPER SHALL FULLY CLOSE.
ALARMS, INTERLOCKS AND SAFETIES:
AN ALARM SHALL BE GENERATED AT THE FMCS OPERATOR WORKSTATION IN THE
EVENT THE FMCS COMMANDS THE EXHAUST FAN TO OPERATE AND THE CURRENT
SENSING RELAY DETECTS INSUFFICIENT CURRENT DRAW.
EXHAUST AIR FROM
PLYMOVENT SYSTEM
EXHAUST AIR FROM
PLYMOVENT SYSTEM
TO ROOFTOP
EXHAUST VENT
OPEN/CLOSE
EXHAUST AIR FROM
PLYMOVENT SYSTEM
FAN
STATUS
CS
START/
STOP
ACT
SEQUENCE OF OPERATION:
1) WHEN HOSE REEL COLLECTION UNIT IS ENABLED MOTOR OPERATED DAMPER
SHALL OPEN AND MODULATE TO MAINTAIN AIRFLOW SETPOINT CFM (ADJ.).
EXHAUST AIRFLOW SETPOINT FROM BUILDING SHALL REMAIN.
2) 2-POSITION DAMPER SHALL FULLY OPEN WHEN FAN IS ENERGIZED. WHEN FAN IS
DE-ENERGIZED, 2-POSITION DAMPER SHALL FULLY CLOSE.
ALARMS, INTERLOCKS AND SAFETIES:
AN ALARM SHALL BE GENERATED AT THE FMCS OPERATOR WORKSTATION IN THE
EVENT THE FMCS COMMANDS THE EXHAUST FAN TO OPERATE AND THE CURRENT
SENSING RELAY DETECTS INSUFFICIENT CURRENT DRAW.
EXHAUST AIR FROM
PLYMOVENT SYSTEM
TO ROOFTOP
EXHAUST VENT
OPEN/CLOSE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314)-692-5195
C U s e rs
\k fi n c k \D o c u m e n ts \1
-J B
N C
F
C A
-M k fi n c k C
D K
.r v t
/2
/2
:2
:0
A
M
3001-MV401
VENTILATION, CONTROL
DIAGRAMS & DETAILS
JEFFERSON BARRACKS
NATIONAL CEMETERY CORRECT
FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
853CM3042
03/28/2024
KTF RWB
17550
PLYMOVENT INSTALLATION
SECTION AT EF-1
RESTROOM EXHAUST SECTION
EXHAUST HOOD DETAIL
EF-1 IN-LINE EXHAUST FAN CONTROL DIAGRAM 6
EF-2 BATHROOM EXHAUST FAN CONTROL DIAGRAM
EF-42 EXHAUST FAN CONTROL DIAGRAM
EF-28 EXHAUST FAN CONTROL DIAGRAM
NO SCALE NO SCALE NO SCALE NO SCALE
NO SCALE
NO SCALE NO SCALE NO SCALE
1.5
DCBA
C
J
J
J J
LIGHTING
PANEL L2B
LIGHTING
PANEL L2A
HEATING
PANEL H2
1 5
1 2
E F
-1
EF-2
F A
N -4
F A
N -2
A
EF-42
208V-3P/20A
PNL H2- 37,39,41
EF-1
PNL L2A- 37
EF-28
PNL L2A- 36
EF-2
PNL L2A- 34
MS
MS
MS
MS
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
T101
SIM
DETAIL REFERRED TO BY ELEVATION
SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
SIM
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
LEVEL NAME
10' - 0" HEIGHT ABOVE
PROJECT 0' - 0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N
O R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR
(DARK LONG DASHED LINE)
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN
(LIGHT SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR
(DARK SHORT DASHED LINE)
LINE TYPE KEY:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMP
321 4 5 6 7 8 9 10
CONSULTANTS
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314) 692-5195
C U s e rs \A
W e b e r\ D o c u m e n ts \1
-J
B N
C F
C A
-E a w e b e r9
S
.r v t
/2
/2
:1
:3
A
M
3001-EP101
ELECTRICAL FLOOR PLAN JEFFERSON BARRACKS
NATIONAL CEMETERY CORRECT
FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
853CM3042
MARCH 28, 2024 ATW JPC
1/8" = 1'-0"
FIRST LEVEL - ELECTRICAL
GENERAL NOTES:
A. ELECTRICAL CONTRACTOR SHALL COORDINATE
EXACT MOUNTING HEIGHTS AND LOCATIONS OF
WALL MOUNTED DEVICES WITH EXISTING EQUIPMENT
AND ARCHITECTURAL ELEVATIONS.
B. ELECTRICAL CONTRACTOR SHALL COORDINATE
EXACT LOCATIONS OF NEW SWITCHES/CONTROLLERS
IN ALL SPACES WITH EQUIPMENT LOCATIONS PRIOR
TO ROUGH-IN. CONTRACTOR SHALL OBTAIN APPROVAL
OF LAYOUTS AND LOCATIONS FROM THE COR. ANY
LOCATION IN WHICH THE COR DEEMS ARE NOT
COORDINATED SHALL BE REWORKED BY THE
CONTRACTOR AT NO ADDITIONAL COST TOTHE
GOVERNMENT.
C. ELECTRICAL CONTRACTOR SHALL FISH NEW WIRING
IN EXISTING WALLS OR CEILING WHERE POSSIBLE. IF
WALLS CANNOT BE FISHED, WIRING SHALL BE RUN IN A
SURFACE APPLIED METALLIC RACEWAY ONLY WHERE
PRE-APPROVED BY THE COR.
D. PROVIDE A UL LISTED FIRESTOPPING SYSTEM FOR ALL
PENETRATIONS AND SLEEVES THROUGH FIRE RATED
CONSTRUCTION UPON CONDUIT AND CABLING
INSTALLATION AS REQUIRED TO MAINTAIN THE INTEGRITY
OF THE RATED ASSEMBLY.
KEYNOTES:
1. (3) NO. 10 THWN & (1) NO.10 GROUND IN 3/4" CONDUIT.
2. APPROXIMATE LOCATION OF PLYMOVENT FAN-28
CONTROLLER FURNISHED BY MECHANICAL CONTRACTOR,
INSTALLED AND WIRED BY ELECTRICAL CONTRACTOR.
COORDINATE EXACT LOCATION AND REQUIREMENTS IN
FIELD.
3. APPROXIMATE LOCATION OF PLYMOVENT FAN-42
CONTROLLER FURNISHED BY MECHANICAL CONTRACTOR,
INSTALLED AND WIRED BY ELECTRICAL CONTRACTOR.
COORDINATE EXACT LOCATION AND REQUIREMENTS IN
FIELD.
4. APPROXIMATE LOCATION OF WALL EXHAUST FAN
CONTROLLER FURNISHED BY MECHANICAL CONTRACTOR,
INSTALLED AND WIRED BY ELECTRICAL CONTRACTOR.
COORDINATE EXACT LOCATION AND REQUIREMENTS IN
FIELD.
5. APPROXIMATE LOCATION OF BATHROOM EXHAUST SWITCH
FURNISHED BY MECHANICAL CONTRACTOR, INSTALLED
AND WIRED BY ELECTRICAL CONTRACTOR. COORDINATE
EXACT LOCATION AND REQUIREMENTS IN FIELD. SEE
DETAIL A1 ON SHEET 3001-EP500.
6. RP - DENOTES EXISTING DEVICE OR FIXTURE THAT SHALL
BE REPLACED WITH NEW IN SAME LOCATION. WIRE TO
EXISTING CIRCUITING AT LOCATION UNLESS OTHERWISE
NOTED.
ELECTRICAL SYMBOLS
SYMBOL DESCRIPTION
GROUND
NEUTRAL HOT
A-1
J J
CONDUIT CONCEALED ABOVE CEILING OR IN WALL WHEREVER POSSIBLE
CONDUIT CONCEALED BELOW SLAB OR GRADE
CONDUIT EXPOSED ON CEILING, WALL OR BAR JOIST FOR EXPOSED
TYPE BUILDING CONSTRUCTION
INDICATES NUMBER OF HOT, NEUTRAL, AND GROUND CONDUCTORS
IN CONDUIT. TO BE USED AS A GENERAL GUIDE TO SHOW INTENT OF
CIRCUITING AND SWITCHING ARRANGEMENT. NOT SHOWN IN ALL
CASES. CONTRACTOR SHALL VERIFY AND INSTALL ADDITIONAL
CONDUCTOR WHERE REQUIRED
HOME RUN TO PANELBOARD SHOWING CIRCUIT DESIGNATION,
INDICATING PANEL AND CIRCUIT BREAKER NUMBER WITHIN PANEL
HUBBELL WIRING DEVICE-KELLEMS OCCUPANCY SENSOR:HARD WIRED
WALL SWITCH BOX, WHITE MANUAL MODEL #WS1000W
120V-1P, 1HP MOTOR RATED SWITCH EQUAL TO LEVITON 1221.
208V, 3HP RATED, COMBINATION MOTOR DISCONNECT, HAND/OFF/AUTO
SWITCH WITH PILOT LIGHT EQUAL TO EATON ECH1601EJ.
JUNCTION BOX
MS
MS
H N 120V
CKT
EF
CIRCUIT BREAKER
LINE VOLTAGE WIRING &
CONDUIT BY E.C.
WS1000W SWITCH IN
INDIVIDUAL RESTROOM.
LIGHT IN BATHROOM.
DISCONNECT SWITCH FURNISHED WITH
EXHAUST FAN INSTALLED BY E.C. ABOVE
ACCESSIBLE CEILING.
FAN ON/OFF
INTERLOCKED WITH
LIGHT SWITCH AND
TIMER
BATHROOM
ZONE AIR
SEQUENCE OF OPERATION (EF-2):
1) THE FAN SHALL RUN DURING OCCUPIED HOURS.
2) EXHAUST FAN SHALL INTERLOCK WITH BATHROOM FAN LIGHTS.
WHEN THE LIGHTS ARE TURNED ON THE EXHAUST FAN WILL START.
WHEN THE LIGHTS ARE TURNED OFF THE EXHAUST FAN WILL RUN
FOR 15 MIN AND SHUT OFF.
ALARMS, INTERLOCKS AND SAFETIES:
NA
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMP
321 4 5 6 7 8 9 10
CONSULTANTS
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314) 692-5195
C U s e rs \A
W e b e r\ D o c u m e n ts \1
-J
B N
C F
C A
-E a w e b e r9
S
.r v t
/2
/2
:1
:3
A
M
3001-EP500
ELECTRICAL DETAILS JEFFERSON BARRACKS
NATIONAL CEMETERY CORRECT
FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
853CM3042
MARCH 28, 2024 ATW JPC
12" = 1'-0"
EXHAUST FAN WIRING DIAGRAM
12" = 1'-0"
EF-2 BATHROOM EXHAUST FAN CONTROL DIAGRAM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTSOffice of Design and Construction
Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
DESIGNER OF RECORD STAMP
321 4 5 6 7 8 9 10
CONSULTANTS
GEOTECHNICAL ENGINEER
TERRACON CONSULTANTS
11600 LILBURN PARK ROAD
ST. LOUIS, MO 63146
(314) 692-5195
C U s e rs \A
W e b e r\ D o c u m e n ts \1
-J
B N
C F
C A
-E a w e b e r9
S
.r v t
/2
/2
:1
:3
A
M
3001-EP600
ELECTRICAL SCHEDULES JEFFERSON BARRACKS
NATIONAL CEMETERY CORRECT
FCA DEFICIENCIES
2900 SHERIDAN ROAD, ST. LOUIS, MO 63125
853CM3042
MARCH 28, 2024 ATW JPC
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 9 A
TOTAL CONNECTED AMPS: 9.02 A
TOTAL ESTIMATED DEMAND LOAD: 3.25 kVA
TOTAL CONNECTED LOAD: 3.25 kVA
Power 3.25 kVA 100.00% 3.25 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
Total Amps: 8.33 8.33 10.42
Total Load: 1.00 kVA 1.00 kVA 1.25 kVA
41 42
39 40
37 EF-1 20 A 1 1 38
35 -- -- -- 0 1.25 1 20 A EF-28 36
33 -- -- -- 0 1 1 20 A EF-2 34
31 WELDER 150 A 3 0 0 1 150 A TL5-4I 32
29 LIGHTS FOR BAY #4 20 A 1 0 0 1 20 A FUEL MOTIONS 30
27 LIGHTS (FRONT 2 OF BAY #1, #2 ... 20 A 1 0 0 1 20 A EX LOAD 28
25 LIGHTS (FRONT 2 OF BAY #1, #2 ... 20 A 1 0 0 -- -- -- 26
23 220 VOLT RECEPT WIREMOLD 20 A 1 0 0 2 20 A TIRE BALANCER 24
21 EX LOAD 20 A 1 0 0 1 20 A RECEPT WASH AREA 22
19 STEAM RECEPT 20 A 1 0 0 1 20 A WORK BENCH 20
17 EX LOAD 20 A 1 0 0 1 20 A EX LOAD 18
15 LTG. OFFICE & CARPENTRY RMS. 20 A 1 0 0 1 20 A EX LOAD 16
13 LTG. PART RM. OIL ROOM FAN... 20 A 1 0 0 1 20 A EX LOAD 14
11 LTG. PAINT RM. 20 A 1 0 0 1 20 A EX LOAD 12
9 LTG. OUTSIDE 20 A 1 0 0 -- -- -- 10
7 LTG. BETWEEN DOOR 20 A 1 0 0 2 20 A EXHAUST FAN EF 2-2 8
5 LTG. WASH AREA 20 A 1 0 0 -- -- -- 6
3 STEAM RECEPT 20 A 1 0 0 -- -- -- 4
1 STEAM RECEPT 20 A 1 0 0 3 20 A OVERHEAD DOOR 2
CKT NO. LOAD DESCRIPTION
OCPD
AMPS
# OF
POLES
A B C # OF
POLES
OCPD
AMPS LOAD DESCRIPTION CKT NO.
NOTES: EXISTING SQUARE D TYPE NQ0B PANELBOARD.
ISC UNKNOWN
SCCR:
LOCATION: WIRE: 4
FED FROM: @ PHASE: 3
ENCLOSURE: Type 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: Surface MAIN: 225 A
LIGHTING PNL L2A
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 9.2 A
TOTAL CONNECTED AMPS: 9.19 A
TOTAL ESTIMATED DEMAND LOAD: 3.31 kVA
TOTAL CONNECTED LOAD: 3.31 kVA
Power 3.31 kVA 100.00% 3.31 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
Total Amps: 9.19 9.19 9.19
Total Load: 1.10 kVA 1.10…