Attachment 3 - GAOA Building Improvements Drawings.pdf
PDF 7 MB Posted
- Attached to
- GAOA Building Improvements Creede Federal contract opportunity
- Solicitation number
- 1240LT24Q0013
- Issued by
- Department of Agriculture Forest Service
About this file
This solicitation is for building improvements at the GAOA Building in Creede, Colorado. The Forest Service is seeking proposals for repairs and renovations to the building located at 304 South Main Street in Creede. Work includes window replacements, concrete and porch repairs, exterior painting, electrical work, and lighting replacements or installations both inside and outside the building. Proposals are due no later than March 20, 2024. The solicitation was issued by the Department of Agriculture Forest Service.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 1240LT24Q0013 - A04 - Building Improvements Creede.pdf | ||
| Atch 09 Conduit Photos.zip | ZIP file | |
| Atch 06 Question and Answer Photos.pdf | ||
| Atch 05 Questions and Answers.pdf | ||
| Atch 08 CAD Drawings Creede.zip | ZIP file | |
| Atch 07 Site Visit Sign-in.pdf | ||
| Atch 10 Site Visit Photos.zip | ZIP file | |
| 1240LT24Q0013-A03 GAOA Building Improvments Creede.pdf | ||
| Amendment 2 1240LT24Q0013 GAOA Building Improvements Creede.pdf | ||
| 1240LT24Q0013-0001 Site Visit.pdf | ||
| Attachment 2 - GAOA Building Improvements Creede Specifications.pdf | ||
| Attachment 4 - WD CO20240001 20240105.pdf | ||
| 1240LT24Q0013 GAOA Building Improvements Creede.pdf | ||
| Attachment 1 - GAOA Building Improvements Creede Schedule of Items.xlsx | XLSX spreadsheet |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE
RECOMMENDED BY:
FOREST ENGINEER
PROJECT MANAGER
REGIONAL ENGINEER
FOREST SUPERVISOR
ENGINEERING/REGIONAL SPECIALIST [CDI MANAGER]
I HAVE REVIEWED THE TECHNICAL ASPECTS OF THESE DRAWINGS:
APPROVED BY:
THESE DRAWINGS COMPLY WITH THE FOREST PLAN AND PROJECT
SPECIFIC NEPA DOCUMENTATION:
DATE
DATE
DATE
DATE
PROJECT ADDRESS
304 SOUTH MAIN STREET
CREEDE, CO 801130
LATITUDE: 37°51'02.6" N
LONGITUDE: 106°55'34.6 W
T1.0 TITLE SHEET AND INDEX
G1.1 ABBREVIATIONS AND PROJECT NOTES
G1.2 PROJECT CODE SUMMARY
A1.1 REHAB FIRST FLOOR AND BASEMENT
A1.2 PHOTOGRAPHS
A1.3 PHOTOGRAPHS
A1.4 WEST AND EAST ELEVATIONS
A1.5 NORTH AND SOUTH ELEVATIONS
E0.1 LEGEND, SCHEDULES, AND GENERAL NOTES
E1.0 BASEMENT ELECTRICAL PLAN
E1.1 FIRST FLOOR ELECTRICAL PLAN
E2.1 PHOTOGRAPHS
SHEET DRAWING TITLE
PROJECT
LOCATION
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _G
EN
ER
AL
.D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
TITLE SHEET
AND
INDEX
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
RIO GRANDE
NATIONAL FOREST
MINERAL COUNTY, COLORADO
CREEDE OFFICE
UPGRADES
PROJECT LOCATION
GAOA - 6260183010602
KODY NATHE Digitally signed by KODY NATHE Date: 2022.12.29 15:01:47 -07'00'
MARGARET SULLIVAN
Digitally signed by MARGARET
SULLIVAN
Date: 2023.01.03 06:30:16 -07'00'
DAN DALLAS Digitally signed by DAN DALLAS Date: 2023.01.03 12:13:17 -07'00'
& AND
< ANGLE
@ AT
℄ CENTER LINE
° DEGREES
Ø DIAMETER
ɸ ELECTRICAL PHASE
' FOOT
FLOWLINE
" INCH
PERPENDICULAR
PITCH, SLOPE
# POUND(S) or NUMBER
⅊ PROPERTY LINE, PLATE
ABC AGGREGATE BASE COURSE
AB ANCHOR BOLT
ABV ABOVE
A/C AIR CONDITIONING
AC ACOUSTICAL
ACT ACOUSTICAL TILE
ADR ACCESS DOOR
AD AREA DRAIN
ADD ADDENDUM
ADH ADHESIVE
ADJ ADJACENT or ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AIP ABANDON IN PLACE
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE (LY)
ARCH ARCHITECT(URAL)
ASPH ASPHALT
ASTM AMERICAN SOCIETY FOR TESTING
AND MATERIALS
AUTO AUTOMATIC
A/V AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AWG AMERICAN WIRE GAUGE
AWP ACOUSTICAL WALL PANEL
B.O. BOTTOM OF
B BASE
BD BOARD
BATT INSULATION
BIT BITUMINOUS
BLDG BUILDING
BLKG BLOCKING
BM BEAM or BENCHMARK
BOL BEGINNING OF LINE
BOT BOTTOM
BR BACKER ROD
BRG BEARING
BS BOTH SIDES
BSMT BASEMENT
BW BOTH WAYS
C CAULKING
CAB CABINET
CAL CALIBER
CAS CASEMENT
CATV CABLE TELEVISION
CB CATCH BASIN
CCTV CLOSED CIRCUIT TELEVISION
CFM CUBIC FEET/MINUTE
CGR COILING GRILLE
CEM CEMENTITIOUS
CFL COUNTERFLASHING
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE CONCRETE
CIRC CIRCUMFERENCE
CJ CONTROL JOINT
CKT CRICKET
CL COLUMN LINE
CLG CEILING
CLR CLEAR(ANCE)
CLOS CLOSET
CM CENTIMETER(S)
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CTR CENTER
CO CONTRACTING OFFICER
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONST CONSTRUCTION
CONT CONTINUOUS or CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER REPRESNT'IVE
CORR CORRIDOR or CORRUGATED
CP CONTROL POINT
CPT CARPET (ED)
CT CERAMIC TILE
CTR COUNTER
CU CUBIC
CW COLD WATER
CWK CASEWORK
CX CONNECTION
CY CUBIC YARD
d PENNY
DAMP DAMPROOFING
DBL DOUBLE
DEMO DEMOLISH or DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPOSAL
DIV DIVISION
DN DOWN
DR DOOR
DS DOWNSPOUT
DSPR DISPENSER
DTL DETAIL
DWG DRAWING
DW DISHWASHER
DWR DRAWER
(E) EXISTING
E EAST
EA EACH
EB EXPANSION BOLT
EC ELECTRICAL COOKTOP
ED EXHAUST DUCT
EF EXHAUST FAN or EACH FACE
EG EXISTING GRADE
EJ EXPANSION JOINT
EL ELEVATION
ELB ELBOW
ELEV ELEVATOR
EMER EMERGENCY
ENC ENCLOSURE
ENGR ENGINEER
ENT ENTRANCE
EOP EDGE OF PAVEMENT
EOR EDGE OF ROAD
EOS EDGE OF SLAB
EP ELECTRICAL PANEL
EOL END OF LINE
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
ESR ELASTIC SHEET ROOFING
EST ESTIMATE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXPN EXPANSION
EXT EXTERIOR
F FAHRENHEIT
FA FIRE ALARM
FAA FEDERAL AVIATION ADMINISTRATION
FAC FIRE ALARM CABINET
FACP FIRE ALARM CONTROL PANEL
FCP FIBER CEMENT PANEL
FD FLOOR DRAIN or FIRE DAMPER
FDTN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FFE FINISHED FLOOR ELEVATION
FG FINISHED GROUND
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FHS FIRE HOSE STATION
FIN FINISH(ED)
FIX FIXED
FIXT FIXTURE
FL FLANGE
FLCO FLOOR CLEANOUT
FLG FLASHING
FLR(G) FLOOR(ING)
FND FOUNDATION
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FR FIRE RATED or FIRE RESISTIVE
FRP FIBERGLASS REINFORCED PANEL(ING)
FRT FIRE RETARDANT TREATED
FT FOOT or FEET
FTG FOOTING
FURN FURNISH(ED)
FURR FURRED or FURRING
GA GAUGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACT (OR)
GCMU GLAZED CONCRETE MASONRY UNIT
GF GOVERNMENT FURNISHED
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GL GLASS or GLAZING
GOVT GOVERNMENT
GR GRADE or GRILLE
GRD GROUND
GRT GROUT
GS GALVANIZED STEEL
GSM GALVANIZED SHEET METAL
GYPBD GYPSUM BOARD
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HDR HEADER
HDPE HIGH DENSITY POLYETHYLENE
HDWR HARDWARE
HK HOOK(S)
HM HOLLOW METAL
HORZ HORIZONTAL
HP HIGH POINT
HR HOUR
HT HEIGHT
HTR HEATER
HVAC HEATING, VENTILATION and AIR
CONDITIONING
HW HOT WATER
HWY HIGHWAY
HYD HYDRANT
ID INSIDE DIAMETER
IN INCH(ES)
INCL INCLUDE (D), (ING)
INFO INFORMATION
INS INSULATAION or INSULATED
INT INTERIOR
INTMED INTERMEDIATE
INV INVERT
IPS IRON PIPE SIZE
JAN JANITOR
JST JOIST
JT JOINT
KD KNOCKDOWN
KIT KITCHEN
KO KNOCKOUT
KP KICK PLATE
LAB LABORATORY
LAM LAMINATE (D)
LAV LAVATORY
LBL LABEL
LF LINEAL, LINEAR FOOT
LH LEFT HAND
LIB LIBRARY
LIN LINEAL
LKR LOCKER
LL LIVE LOAD
LT LIGHT
LTL LINTEL
LVR LOUVER
MACH MACHINERY
MAG MAGNETIC
MAINT MAINTAIN (ENANCE)
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MECH MECHANIC (AL)
MED MEDIUM
MEDC MEDICINE CABINET
MEMB MEMBRANE
MEP MECHANICAL, PLUMBING and PLUMBING
METL METAL
MEZZ MEZZANINE
MFR MANUFACTURE (ER)
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MM MILLIMETERS
MO MASONRY OPENING
MR MOISTURE RESISTANT
MT MOUNT (ED), (ING)
MTL METAL
MUL MULLION
MUTCD MANUAL ON UNIFORM
TRAFFIC CONTROL DEVICES
(N) NEW
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NPT NATIONAL PIPE THREAD
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O/ OVER
OA OVERALL
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OFF OFFICE
OH OVERHEAD
OPG OPENING
OPH OPPOSITE HAND
OPP OPPOSITE
OPS OPERATIONS
ORD OVERFLOW ROOF DRAIN
OTO OUTSIDE-TO-OUTSIDE
OZ OUNCE
PAR PARALLEL
PC PRECAST
PED PEDESTRIAN
PERF PERFORATED
PERIM PERIMETER
PH PHOTO
PKG PARKING
PL PROPERTY LINE or PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PNL PANEL
PNT PAINT(ED)
POL POLISHED
PR PAIR
PREFAB PREFABRICATED
PREFIN PREFINISHED
PRIM PRIMARY
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT OF TANGENCY or PORCELAIN TILE or POST TENSIONED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER
AND RECEPTACLE
PTN PARTITION
PTR PAPER TOWEL RECEPTOR
PVC POLYVINYL CHLORIDE
PVC POINT OF VERTICAL CURVE
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENT
PVMT PAVEMENT
PWD PLYWOOD
QT QUARRY TILE
QTY QUANTITY
(R) REMOVE
R RESISTANCE or RISER
RAD RADIUS
RB RUBBER BASE
RBC RUBBER BASE COVE
RBS RUBBER BASE STRAIGHT
RBT RUBBER TILE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN or ROAD RE REFERENCE or REFER TO
REC RECESS(ED)
RECP RECEPTACLE
REF REFRIGERATOR or REFRIGERATED
REINF REINFORCED
RESIL RESILIENT
REQ REQUIRED
REV REVISE(D) or REVISION
RF RESILIENT FLOORING
RFG ROOFING
RFL REFLECTED
RH RIGHT HAND
RINS RIGID INSULATION
RM ROOM
RO ROUGH OPENING
ROD ROOF OVERFLOW DRAIN
ROW RIGHT OF WAY
RP RADIANT PANEL
RVS REVERSE
S SOUTH or SEALED
SBLK SPLASH BLOCK
SC SOLID CORE
SCD SEAT COVER DISPENSER
SCH SCHEDULE
SD STORM DRAIN or SOAP DISPENSER
SEC SECTION
SF SQUARE FEET
SGT STRUCTURAL GLAZED TILE
SH SHELF, SHELVING
SHT SHEET
SHTHG SHEATHING
SHWR SHOWER
SIM SIMILIAR
SIP STRUCTURAL INSULATED PANEL
SNC SANITARY NAPKIN CABINET
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTOR
SOFF SOFFIT
SOG SLAB ON GRADE
SPC SPACER/SHIM
SPEC SPECIFICATION (S)
SPKL SPRINKLER
SPKR SPEAKER
SPRT SUPPORT
SQ SQUARE
SSK SERVICE SINK
SS STAINLESS STEEL or SOLID SURFACE
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SWBD SWITCHBOARD
SYM SYMMETRICAL
SYS SYSTEM
T.O. TOP OF
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TEST BORING or TOWEL BAR
TEL TELEPHONE
TEMP TEMPERATURE or TEMPORARY
TG TEMPERED GLASS
THERM THERMOSTAT
THK THICK (NESS)
THR THRESHOLD
THRU THROUGH
TOB TOP OF BEAM
TOC TOP OF CURB or CONCRETE
TOP TOP OF PARAPET
TOS TOP OF SLAB or STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPTN TOILET PARTITION
TR TRANSOM
TRANSL TRANSLUCENT
TS TUBE STEEL
TV TELEVISION
TWB TREATED WOOD BLOCKING
TX TRANSFORMER
TYP TYPICAL
TZ TERRAZZO
UC UNDERCUT
UL UNDERWRITERS LABORATORY
UNFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
UR URINAL
V VOLT
VAR VARIABLE or VARIES
VB VAPOR BARRIER
VC VERTICAL CURVE
VCT VINYL COMPOSITION TILE
VENT VENTILATION
VER VERIFY
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VIN VINYL or SHEET VINYL
VOL VOLUME
VTR VENT THROUGH ROOF
W.O. WHERE OCCURS
W WEST, WIDE or WIDTH
W/ WITH
W/C WATER CLOSET
W/O WITHOUT
WC WALL COVERING
WD WOOD
WF WIDE FLANGE or WOOD FLOORING WH WALL HYDRANT or WATER HEATER
WIN WINDOW
WP (G) WATERPROOF (ING)
WPT WORK POINT
WR WATER RESISTANT
WWF WELDED WIRE FABRIC
WGL WIRE GLASS
WSCT WAINSCOT
WT WEIGHT
x BY
XFMR TRANSFORMER CONTROL DEVICE
YD YARD
1. THE TERM 'GC' SHALL MEAN THE GENERAL
CONTRACTOR AND ITS SUBCONTRACTORS.
2. THE GC SHALL THOROUGHLY FAMILIARIZE
ITSELF W/ THE CONTRACT DOCUMENTS
AND THE SITE. SHOULD THE GC FIND
DISCREPANCIES IN, OR OMISSIONS FROM
THE DRAWINGS OR SPECIFICATIONS,
SHOULD THE GC BE IN DOUBT AS TO THEIR
INTENT OR MEANING, OR HAS QUESTIONS
CONCERNING CONSTRUCTABILITY OR
CODE COMPLIANCE, THE GC SHALL SEEK
CLARIFICATION FROM THE CO BEFORE
PROCEEDING W/ THE WORK. SHOULD A
CONFLICT OCCUR BETWEEN THE
DRAWINGS AND SPECIFICATIONS, THAT
IMPLYING GREATER QUANTITY OR QUALITY
SHALL PREVAIL.
3. THE INTENT OF THE CONTRACT
DOCUMENTS IS TO PROVIDE A COMPLETE
PROJECT, EVERY ITEM NECESSARILY
REQUIRED MAY NOT BE SPECIFICALLY
MENTIONED OR SHOWN. UNLESS
EXPRESSLY STATED, SYSTEMS AND
EQUIPMENT SHALL BE COMPLETELY
OPERATIONAL. PROVIDE INCIDENTAL,
ACCESSORY, AND ANY OTHER ITEMS NOT
SPECIFIED, BUT REQUIRED, FOR A
COMPLETE AND FINISHED ASSEMBLY.
4. THE ENTIRE SET OF CONTRACT
DOCUMENTS REPRESENT THE PROJECT AS
A WHOLE. THE GC IS RESPONSIBLE FOR
PROVIDING SUFFICIENT INFORMATION TO
ITS SUB-CONTRACTORS TO DETERMINE
AND PERFORM THEIR SCOPE OF WORK.
5. ANY ELECTRONIC CAD AND/OR BUILDING
INFORMATION MODELING (BIM) FILES
PROVIDED BY THE USFS IS SOLELY TO
ASSIST THE GC IN PREPARATION OF SHOP
DRAWINGS AND/OR LAYOUT OF THE
PROJECT. CAD AND BIM FILES ARE NOT A
PART OF THE CONTRACT DOCUMENTS, AND
ANY INFORMATION CONTAINED THEREIN
DOES NOT SUPERSEDE ANY INFORMATION
WITHIN THE CONTRACT DOCUMENTS.
6. THE GC IS RESPONSIBLE FOR MEANS AND
METHODS OF CONSTRUCTION,
COORDINATION OF TRADES, AND
SCHEDULING OF THE WORK.
7. THE GC SHALL NOT REVISE, SUBSTITUTE,
OR CHANGE THE WORK WITHOUT THE
WRITTEN CONSENT OF THE CO.
8. NOT EVERY CONDITION MAY BE DRAWN OR
DETAILED. CONDITIONS SIMILAR TO
DETAILED CONDITIONS SHALL BE
CONSTRUCTED TO THE SAME SIZE AND
CHARACTER AS THOSE FOR SIMILAR
CONDITIONS.
9. DO NOT SCALE THE DRAWINGS.
10. PROVIDE NECESSARY BLOCKING WHERE
REQUIRED IN WALLS, PARTITIONS, AND
CEILINGS FOR ITEMS INCLUDING, BUT NOT
LIMITED TO, THE FOLLOWING: PARTITION
AND CEILING-MOUNTED FIXTURES, GRAB
BARS, HANDRAILS, GUARDRAILS,
RESTROOM ACCESSORIES, CABINETRY,
PANELING, COUNTERTOPS, SHELVES,
CLOSET RODS, WHITE BOARDS, AND
DECORATIVE ELEMENTS.
11. THE CONTRACT DOCUMENTS ARE THE
PROPERTY OF THE USFS AND ITS
CONSULTANTS, AND ARE TO BE USED AS
INSTRUMENTS OF SERVICE FOR THE
CONSTRUCTION OF THIS PROJECT ONLY.
USE OF THESE DOCUMENTS BY THE GC
FOR ANY OTHER PROJECT OR PURPOSE
WITHOUT THE WRITTEN CONSENT OF THE
USFS IS PROHIBITED.
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _G
EN
ER
AL
.D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
ABBREVIATIONS
AND
PROJECT NOTES
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
PROJECT NOTES
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL EXISTING BUILDING CODE, (IEBC)
ALTERATION LEVEL 1
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2021 INTERNATIONAL FIRE CODE (IFC)
2021 INTERNATIONAL FUEL & GAS CODE (IFGC)
2021 INTERNATIONAL PLUMBING CODE (IPC)
2021 NFPA 72 NATIONAL FIRE ALARM CODE
2021 NFPA 101 LIFE SAFETY CODE
2020 NATIONAL ELECTRICAL CODE (NEC)
ADA, ABA OF 1968 ACCESSIBILITY STANDARDS (ABA)
ASHRAE 55 - 2019, THERMAL ENVIRONMENTAL CONDITIONS FOR HUMAN OCCUPANCY
ASHRAE 62.1 - 2019, VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY
ASHRAE 90.1 - 2019, ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS
USFS SUSTAINABILITY GUIDELINES
US DEPARTMENT OF COMMERCE, 2021 ENERGY PRICE INDICES AND DISCOUNT FACTORS FOR LIFE CYCLE COST
ANALYSIS
ZONING DESIGNATION: B-1
CONSTRUCTION TYPE: V-B
OCCUPANCY: BUSINESS (B)
ALLOWABLE HEIGHT: 40'-0” ABOVE GRADE PLANE, PER IBC TBL 504.3 (B)
(2) STORIES ABOVE GRADE PLANE, PER IBC TBL 504.4 (B)
ACTUAL HEIGHT: 21'-4” ABOVE GRADE PLANE
(2) STORIES ABOVE GRADE PLANE
ALLOWABLE AREA: BASIC ALLOWABLE = 9,000 SF (B) PER IBC TBL 506.2
FRONTAGE INCREASE = 4,500 SF 0.5 PER IBC TBL 506.3.3
TOTAL ALLOWABLE = 13,500 SF
ACTUAL AREA: LEVEL 0: 2,343 SF
LEVEL 1: 2,647 SF
TOTAL: 4,990 SF
FIRE SUPPRESSION: NOT REQUIRED BY IBC 903 DUE TO EXISTING HEIGHT AND AREA.
FIRE RESISTANCE RATING REQUIREMENT FOR BUILDFING ELEMENTS:
PRIMARY STRUCTURAL FRAME: 0 HR, PER IBC TBL 601
EXT BEARING WALLS: 0 HR
INT BEARING WALLS: 0 HR
EXT NON-BEARING WALLS: 0 HR
INT NON-BEARING WALLS: 0 HR
FLOOR CONSTRUCTION: 0 HR
ROOF CONSTRUCTION: 0 HR
FIRE RESISTANCE RATING REQUIREMENTS FOR EXT WALLS BASED ON FIRE SEPARATION DISTANCE:
10' < x < 30': 0 HR, PER IBC TBL 705.5
SHAFT ENCLOSURES: 1 HR PER IBC 713.4
ALLOWABLE AREA OF UNPROTECTED OPENINGS BASED ON FIRE SEPARATION DISTANCE:
0'-3': NOT PERMITTED, PER IBC TBL 705.8
3'-5': NOT PERMITTED
5'-10': 10% 10'-15': 15% 15'-20': 25% 20'-25': 45% 25'-30': 70%
> 30': NO LIMIT
OCCUPANT LOAD: (B) 150 GROSS PER TABLE 1004.5
34 OCCUPANTS FOR 4,990 SF
COMMON PATH OF TRAVEL: (B) 75' MAX. PER IBC TBL 1006.2.1
NUMBER OF EXITS | MEANS OF EGRESS:
(2) EXIT PER IBC TBL 1006.2.1, NOTING MAX. TRAVEL DISTANCE OF 75'
SEPARATION DISTANCE OF EXIT/EXIT ACCESS DOORS SHALL NOT BE LESS THAN 1/2 THE
LENGTH OF THE MAXIMUM OVERALL DIAGONAL DISTANCE OF THE AREA SERVED PER IBC
1007.1.1
EXIT ACCESS TRAVEL DISTANCE: (B) 200' MAX. PER IBC TBL 1017.2
CORRIDOR FIRE-RESISTANCE: (B) 1 HR PER IBC TBL 1020.1
CORRIDOR WIDTH MINIMUM: 36" W/ AN OCCUPANT LOAD OF LESS THAN 50, PER IBC TBL 1020.3
DEAD-END LIMIT: 20' MAX. PER IBC 1020.5
EXIT ACCESS STAIR ENCLOSURE: 1 HR FIRE RESISTANCE RATING PER 1023.2, AS FIRE BARRIERS
EXIT PASSAGEWAY: 1 HR FIRE RESISTANCE RATING PER 1023.3.1, AS FIRE BARRIERS
EXIT WIDTH: 36" MINIMUM WHEN SERVING OCCUPANT LOADS LESS THAN 50 PER IBC 1024.2
STAIRWAYS OTHER EGRESS COMPONENTS
0.3 PER OCC., PER IBC 1005.3.1 0.2 PER OCC., PER IBC 1005.3.2
FIRE ALARM: NOT REQUIRED
SMOKE DETECTION: NOT REQUIRED
MISC. EMERGENCY ALARM(S): NOT REQUIRED
PORTABLE FIRE EXTINGUISHERS: REQUIRED PER IBC 906.1
MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER IS 75' PER TABLE 906.3(1)
INT WALL & CEILING REQUIREMENTS @ EXIT STAIRS AND PASSAGEWAYS: CLASS 'A' PER TABLE 803.13
INT WALL & CEILING REQUIREMENTS @ CORRIDORS AND EXIT ACCESS STAIRS: CLASS 'B' PER TABLE 803.13
INT WALL & CEILING REQUIREMENTS @ ROOMS AND ENCLOSED SPACES: CLASS 'C' PER TABLE 803.13
ROOF COVERING CLASSIFICATION: CLASS 'C' PER TABLE 1505.1
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _G
EN
ER
AL
.D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
PROJECT CODE
SUMMARY
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
CODE SUMMARYAPPLICABLE CODES
PORCH
CLOSET
12"X8" VENT SCREENED
BACK.
COAL CHUTE
WOOD STORAGEHEATER ROOM
HALL
STORAGE ROOM
UNEXCAVATED
12"X8" VENT SCREENED
BACK
STORAGE ROOM
UNEXCAVAT'D STORAGE
CLOSET
OFFICE
UNEXCAVAT'D OFFICE
CLO.
24" x 18" BATTEN
DOOR
12" x 8" VENT
SCREENED
BACK
24" x 18"
OPENING
TYPE
WINDOW REPLACEMENT SCHEDULE
WINDOW NO.
52"H x 78"W
CAS-FIX-CAS
CAS-FIX-FIX-CAS
CAS-CAS
DIMENSIONS
FIELD VERIFY DIMENSIONS
REMARKS
52"H x 58"W
40"H x 40"W
21 3 4
15"H x 34"WCAS
FIELD VERIFY DIMENSIONS
FIELD VERIFY DIMENSIONS
FIELD VERIFY DIMENSIONS
FIELD VERIFY DIMENSIONS15"H x 22"WCAS
TYPE
WINDOW FIX SCHEDULE
WINDOW NO.
52"H x 78"W
CAS-FIX-CAS
CAS-FIX-FIX-CAS
DIMENSIONS
FIELD VERIFY DIMENSIONS
REMARKS
52"H x 58"W FIELD VERIFY DIMENSIONS
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _A
R C
H .D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
REHAB FIRST FLOOR
AND BASEMENT
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
FIRST FLOOR BASEMENT
PH5
A1.2
PH1
A1.2
PH3
A1.2 PH4
A1.2
PH2
A1.2
PH5
A1.2
PH1
A1.2
PH3
A1.2
PH2
A1.2
A1.4
A1.4
A1.4
A1.5
A1.5
A1.4
A1.5
A1.5
PH1,2
A1.3
PH4
A1.3 PH3
A1.3
PH5
A1.3
PH6
A1.3
PH7
A1.3
PH8
A1.3
PH9
A1.3
PH4
A1.2
8 0 8 16
SCALE OF FEET
REMOVE (E) SEALANT, FLASHING AND SIDING ADJACENT
TO (E) WINDOW, AS REQUIRED TO REMOVE (E) WINDOW,
FRAME, TRIM, AND ASSOCIATED COMPONENTS, TYP.
SALVAGE AND REUSE SIDING WHERE POSSIBLE.
SHIM (E) FRAMING AS NECESSARY, DO NOT CUT (E)
HEADER OR STUDS. INSTALL (N) WINDOWS IN (E) OPENING
AT SAME TOP ELEV, RE-TAPE/RE-APPLY WEATHER
BARRIER (IF PRESENT) FOR POSITIVE DRAINAGE. INSTALL
FRAMES, TRIM, BACKER ROD, SEALANT, FLASHING, AIR
SEAL TAPE AND ASSOCIATED COMPONENTS, TYP.
REATTACH SIDING TO MATCH ADJACENT FIELD OF (E)
MATERIAL/FINISH. IF DISCREPANCY, NOTIFY CO.
PROTECT (E) WINDOW SILLS AND INT FINISHES, TYP.
PATCH AND PAINT ANY DAMAGED INT DRYWALL AND
PLASTER CAUSED BY WINDOW REPLACEMENT/REPAIR TO
MATCH ADJACENT FIELD OF (E) MATERIAL/FINISH.
DEMO AND REHAB KEYNOTES
ENTIRE BUILDING: REMOVE (E) PAINT FROM (E)
ELECTRICAL, MECHANICAL, AND PLUMBING SYSTEMS
EQUIPMENT ATTACHED TO THE BUILDING, CLEAN
AND PREP SURFACES. APPLY (1) COAT PRIMER, (2)
COATS LATEX PAINT. DO NOT PAINT (N) EQUIPMENT.
FRONT PORCH: REPAIR/SECURE WD HANDRAIL.
REPAIR CONCRETE. REMOVE (E) AND/OR PREPARE
CONCRETE FOR POUR OR PATCH WORK. WHERE (E)
CONCRETE TO REMAIN, REMOVE DIRT AND
VEGETATION. CLEAN AND STRIP (E) PAINT FROM (E)
SURFACE. STAIR AND LANDING CONSTRUCTION TO
COMPLY W/ 2021 IBC, SECTION 1101 REQUIRMENTS,
TYP. PROVIDE PREFINISHED MTL FLASHING W/ DRIP
EDGE WHERE CONCRETE ABUTS (E) SIDING FOR
POSITIVE DRAINAGE. PAINT ALL CONCRETE W/ (1)
COAT CONCRETE PRIMER, (2-3) COATS ELASTOMERIC
(MASONRY) PAINT.
PATCH, SAND, VARNISH ANY DAMAGED (E) WINDOW SILL. INSTALL
CONT., COLOR-MATCH SEALANT AT WINDOW-TO-SILL INTERFACE.
REPAIR (E) WINDOW TO ENSURE OPERABILITY. IF UNABLE TO
REPAIR (E) WINDOW(S), REPLACE PER KEYNOTES 1-4.
ENTIRE BUILDING: REMOVE (E) EXT SIGNAGE, DOWNSPOUTS AND
GUTTERS AS NEEDED, STORE FOR REINSTALLATION. STRIP (E)
PAINT FROM BUILDING. PATCH ANY GOUGES OR GAPS W/
TWO-PART WOOD-EPOXY. INFILL CRACKS W/ PAINT-READY
SEALANT, SAND SURFACE UNTIL SMOOTH. HAND APPLY SOLUTION
TO KILL ANY MOLD OR MILDEW PRESENT, DO NOT POWERWASH.
APPLY CLEAR WATER REPELLANT W/ ANTI-MILDEW PROPERTIES.
PAINT EXT W/ (1) COAT PRIMER, (2) COATS TOP PAINT, INCLUDING
WD SIDING, GABLE ENDS, CORBELS, AWNINGS, RAFTER TAILS,
EAVES, TRIM, PLANTER BOXES, COLUMNS, HAND RAILS, ACCESS
DOORS, VENTS, AND CONCRETE STEM WALLS, TYP. REINSTALL
EXT SIGNAGE, DOWNSPOUTS AND GUTTERS AT (E) LOCATIONS.
ENSURE ATTIC VENT(S) PROVIDE VENTILATION AS REQUIRED THROUGH CONSISTENT SCREEN/GRATE
MATERIAL, REPLACE AS REQUIRED AND/OR PROTECT (E) DURING EXT PAINTING SCOPE.
REPAIR (E) FENCE, PAINT W/ (1) COAT PRIMER, (2) COATS TOP PAINT.
1. (E) INFORMATION SHOWN ON DRAWINGS AND PHOTOGRAPHS HAS BEEN TAKEN FROM LIMITED FIELD
OBSERVATIONS. FIELD VERIFY (E) CONDITIONS PRIOR TO BEGINNING WORK.
2. CORRECT AREAS AFFECTED BY INSTALLATIONS, MAINTAIN (E) ACCESS AND OPERABILITY, TYP.
3. MATCH (E) EXT PAINT SCHEME W/ THE FOLLOWING:
DARK - SHERWIN WILLIAMS DURATION EXTERIOR ACRYLIC SATIN FRENCH ROAST SW 6069
LIGHT - SHERWIN WILLIAMS DURATION EXTERIOR ACRYLIC SATIN JERSEY CREAM SW 6379
GENERAL NOTES
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _A
R C
H .D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
PHOTOGRAPHS
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
PH4
A1.1
PH1
A1.1
PH2
A1.1
PH3
A1.1
REMOVE (E) SEALANT, FLASHING AND SIDING ADJACENT
TO (E) WINDOW, AS REQUIRED TO REMOVE (E) WINDOW,
FRAME, TRIM, AND ASSOCIATED COMPONENTS, TYP.
SALVAGE AND REUSE SIDING WHERE POSSIBLE.
SHIM (E) FRAMING AS NECESSARY, DO NOT CUT (E)
HEADER OR STUDS. INSTALL (N) WINDOWS IN (E) OPENING
AT SAME TOP ELEV, RE-TAPE/RE-APPLY WEATHER
BARRIER (IF PRESENT) FOR POSITIVE DRAINAGE. INSTALL
FRAMES, TRIM, BACKER ROD, SEALANT, FLASHING, AIR
SEAL TAPE AND ASSOCIATED COMPONENTS, TYP.
REATTACH SIDING TO MATCH ADJACENT FIELD OF (E)
MATERIAL/FINISH. IF DISCREPANCY, NOTIFY CO.
PROTECT (E) WINDOW SILLS AND INT FINISHES, TYP.
PATCH AND PAINT ANY DAMAGED INT DRYWALL AND
PLASTER CAUSED BY WINDOW REPLACEMENT/REPAIR TO
MATCH ADJACENT FIELD OF (E) MATERIAL/FINISH.
DEMO AND REHAB KEYNOTES
ENTIRE BUILDING: REMOVE (E) PAINT FROM (E)
ELECTRICAL, MECHANICAL, AND PLUMBING SYSTEMS
EQUIPMENT ATTACHED TO THE BUILDING, CLEAN
AND PREP SURFACES. APPLY (1) COAT PRIMER, (2)
COATS LATEX PAINT. DO NOT PAINT (N) EQUIPMENT.
FRONT PORCH: REPAIR/SECURE WD HANDRAIL.
REPAIR CONCRETE. REMOVE (E) AND/OR PREPARE
CONCRETE FOR POUR OR PATCH WORK. WHERE (E)
CONCRETE TO REMAIN, REMOVE DIRT AND
VEGETATION. CLEAN AND STRIP (E) PAINT FROM (E)
SURFACE. STAIR AND LANDING CONSTRUCTION TO
COMPLY W/ 2021 IBC, SECTION 1101 REQUIRMENTS,
TYP. PROVIDE PREFINISHED MTL FLASHING W/ DRIP
EDGE WHERE CONCRETE ABUTS (E) SIDING FOR
POSITIVE DRAINAGE. PAINT ALL CONCRETE W/ (1)
COAT CONCRETE PRIMER, (2-3) COATS ELASTOMERIC
(MASONRY) PAINT.
PATCH, SAND, VARNISH ANY DAMAGED (E) WINDOW SILL. INSTALL
CONT., COLOR-MATCH SEALANT AT WINDOW-TO-SILL INTERFACE.
REPAIR (E) WINDOW TO ENSURE OPERABILITY. IF UNABLE TO
REPAIR (E) WINDOW(S), REPLACE PER KEYNOTES 1-4.
ENTIRE BUILDING: REMOVE (E) EXT SIGNAGE, DOWNSPOUTS AND
GUTTERS AS NEEDED, STORE FOR REINSTALLATION. STRIP (E)
PAINT FROM BUILDING. PATCH ANY GOUGES OR GAPS W/
TWO-PART WOOD-EPOXY. INFILL CRACKS W/ PAINT-READY
SEALANT, SAND SURFACE UNTIL SMOOTH. HAND APPLY SOLUTION
TO KILL ANY MOLD OR MILDEW PRESENT, DO NOT POWERWASH.
APPLY CLEAR WATER REPELLANT W/ ANTI-MILDEW PROPERTIES.
PAINT EXT W/ (1) COAT PRIMER, (2) COATS TOP PAINT, INCLUDING
WD SIDING, GABLE ENDS, CORBELS, AWNINGS, RAFTER TAILS,
EAVES, TRIM, PLANTER BOXES, COLUMNS, HAND RAILS, ACCESS
DOORS, VENTS, AND CONCRETE STEM WALLS, TYP. REINSTALL
EXT SIGNAGE, DOWNSPOUTS AND GUTTERS AT (E) LOCATIONS.
ENSURE ATTIC VENT(S) PROVIDE VENTILATION AS REQUIRED THROUGH CONSISTENT SCREEN/GRATE
MATERIAL, REPLACE AS REQUIRED AND/OR PROTECT (E) DURING EXT PAINTING SCOPE.
REPAIR (E) FENCE, PAINT W/ (1) COAT PRIMER, (2) COATS TOP PAINT.
1. (E) INFORMATION SHOWN ON DRAWINGS AND PHOTOGRAPHS HAS BEEN TAKEN FROM LIMITED FIELD
OBSERVATIONS. FIELD VERIFY (E) CONDITIONS PRIOR TO BEGINNING WORK.
2. CORRECT AREAS AFFECTED BY INSTALLATIONS, MAINTAIN (E) ACCESS AND OPERABILITY, TYP.
3. MATCH (E) EXT PAINT SCHEME W/ THE FOLLOWING:
DARK - SHERWIN WILLIAMS DURATION EXTERIOR ACRYLIC SATIN FRENCH ROAST SW 6069
LIGHT - SHERWIN WILLIAMS DURATION EXTERIOR ACRYLIC SATIN JERSEY CREAM SW 6379
GENERAL NOTES
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _A
R C
H .D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
PHOTOGRAPHS
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
PH2
A1.1
PH3
A1.1
PH5
A1.1
PH6
A1.1
PH4
A1.1
PH1
A1.1
PH9
A1.1
PH7
A1.1
PH8
A1.1
1 1 5
REMOVE (E) SEALANT, FLASHING AND SIDING ADJACENT
TO (E) WINDOW, AS REQUIRED TO REMOVE (E) WINDOW,
FRAME, TRIM, AND ASSOCIATED COMPONENTS, TYP.
SALVAGE AND REUSE SIDING WHERE POSSIBLE.
SHIM (E) FRAMING AS NECESSARY, DO NOT CUT (E)
HEADER OR STUDS. INSTALL (N) WINDOWS IN (E) OPENING
AT SAME TOP ELEV, RE-TAPE/RE-APPLY WEATHER
BARRIER (IF PRESENT) FOR POSITIVE DRAINAGE. INSTALL
FRAMES, TRIM, BACKER ROD, SEALANT, FLASHING, AIR
SEAL TAPE AND ASSOCIATED COMPONENTS, TYP.
REATTACH SIDING TO MATCH ADJACENT FIELD OF (E)
MATERIAL/FINISH. IF DISCREPANCY, NOTIFY CO.
PROTECT (E) WINDOW SILLS AND INT FINISHES, TYP.
PATCH AND PAINT ANY DAMAGED INT DRYWALL AND
PLASTER CAUSED BY WINDOW REPLACEMENT/REPAIR TO
MATCH ADJACENT FIELD OF (E) MATERIAL/FINISH.
DEMO AND REHAB KEYNOTES
ENTIRE BUILDING: REMOVE (E) PAINT FROM (E)
ELECTRICAL, MECHANICAL, AND PLUMBING SYSTEMS
EQUIPMENT ATTACHED TO THE BUILDING, CLEAN
AND PREP SURFACES. APPLY (1) COAT PRIMER, (2)
COATS LATEX PAINT. DO NOT PAINT (N) EQUIPMENT.
FRONT PORCH: REPAIR/SECURE WD HANDRAIL.
REPAIR CONCRETE. REMOVE (E) AND/OR PREPARE
CONCRETE FOR POUR OR PATCH WORK. WHERE (E)
CONCRETE TO REMAIN, REMOVE DIRT AND
VEGETATION. CLEAN AND STRIP (E) PAINT FROM (E)
SURFACE. STAIR AND LANDING CONSTRUCTION TO
COMPLY W/ 2021 IBC, SECTION 1101 REQUIRMENTS,
TYP. PROVIDE PREFINISHED MTL FLASHING W/ DRIP
EDGE WHERE CONCRETE ABUTS (E) SIDING FOR
POSITIVE DRAINAGE. PAINT ALL CONCRETE W/ (1)
COAT CONCRETE PRIMER, (2-3) COATS ELASTOMERIC
(MASONRY) PAINT.
PATCH, SAND, VARNISH ANY DAMAGED (E) WINDOW SILL. INSTALL
CONT., COLOR-MATCH SEALANT AT WINDOW-TO-SILL INTERFACE.
REPAIR (E) WINDOW TO ENSURE OPERABILITY. IF UNABLE TO
REPAIR (E) WINDOW(S), REPLACE PER KEYNOTES 1-4.
ENTIRE BUILDING: REMOVE (E) EXT SIGNAGE, DOWNSPOUTS AND
GUTTERS AS NEEDED, STORE FOR REINSTALLATION. STRIP (E)
PAINT FROM BUILDING. PATCH ANY GOUGES OR GAPS W/
TWO-PART WOOD-EPOXY. INFILL CRACKS W/ PAINT-READY
SEALANT, SAND SURFACE UNTIL SMOOTH. HAND APPLY SOLUTION
TO KILL ANY MOLD OR MILDEW PRESENT, DO NOT POWERWASH.
APPLY CLEAR WATER REPELLANT W/ ANTI-MILDEW PROPERTIES.
PAINT EXT W/ (1) COAT PRIMER, (2) COATS TOP PAINT, INCLUDING
WD SIDING, GABLE ENDS, CORBELS, AWNINGS, RAFTER TAILS,
EAVES, TRIM, PLANTER BOXES, COLUMNS, HAND RAILS, ACCESS
DOORS, VENTS, AND CONCRETE STEM WALLS, TYP. REINSTALL
EXT SIGNAGE, DOWNSPOUTS AND GUTTERS AT (E) LOCATIONS.
ENSURE ATTIC VENT(S) PROVIDE VENTILATION AS REQUIRED THROUGH CONSISTENT SCREEN/GRATE
MATERIAL, REPLACE AS REQUIRED AND/OR PROTECT (E) DURING EXT PAINTING SCOPE.
REPAIR (E) FENCE, PAINT W/ (1) COAT PRIMER, (2) COATS TOP PAINT.
1. (E) INFORMATION SHOWN ON DRAWINGS AND PHOTOGRAPHS HAS BEEN TAKEN FROM LIMITED FIELD
OBSERVATIONS. FIELD VERIFY (E) CONDITIONS PRIOR TO BEGINNING WORK.
2. CORRECT AREAS AFFECTED BY INSTALLATIONS, MAINTAIN (E) ACCESS AND OPERABILITY, TYP.
3. MATCH (E) EXT PAINT SCHEME W/ THE FOLLOWING:
DARK - SHERWIN WILLIAMS DURATION EXTERIOR ACRYLIC SATIN FRENCH ROAST SW 6069
LIGHT - SHERWIN WILLIAMS DURATION EXTERIOR ACRYLIC SATIN JERSEY CREAM SW 6379
1 2 3
5 4 46
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _A
R C
H .D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
WEST AND EAST
ELEVATIONS
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
WEST ELEVATION
EAST ELEVATION
A1.4
A1.4
REMOVE (E) SEALANT, FLASHING AND SIDING ADJACENT TO (E)
WINDOW, AS REQUIRED TO REMOVE (E) WINDOW, FRAME,
TRIM, AND
ASSOCIATED COMPONENTS, TYP. SALVAGE AND REUSE SIDING
WHERE POSSIBLE.
SHIM (E) FRAMING AS NECESSARY, DO NOT CUT (E) HEADER
OR STUDS. INSTALL (N) WINDOWS IN (E) OPENING AT SAME
TOP ELEV, RE-TAPE/RE-APPLY WEATHER BARRIER (IF
PRESENT) FOR POSITIVE DRAINAGE. INSTALL FRAMES, TRIM,
BACKER ROD, SEALANT, FLASHING, AIR SEAL TAPE AND
ASSOCIATED COMPONENTS, TYP. REATTACH SIDING TO
MATCH ADJACENT FIELD OF (E) MATERIAL/FINISH. IF
DISCREPANCY, NOTIFY CO.
PROTECT (E) WINDOW SILLS AND INT FINISHES, TYP. PATCH
AND PAINT ANY DAMAGED INT DRYWALL AND PLASTER
CAUSED BY WINDOW REPLACEMENT/REPAIR TO MATCH
ADJACENT FIELD OF (E) MATERIAL/FINISH.
PATCH, SAND, VARNISH ANY DAMAGED (E) WINDOW SILL.
INSTALL CONT., COLOR-MATCH SEALANT AT WINDOW-TO-SILL
INTERFACE.
REPAIR (E) WINDOW TO ENSURE OPERABILITY. IF UNABLE TO
REPAIR (E) WINDOW(S), REPLACE PER KEYNOTES 1-4.
ENTIRE BUILDING: REMOVE (E) EXT SIGNAGE, DOWNSPOUTS
AND GUTTERS AS NEEDED, STORE FOR REINSTALLATION.
STRIP (E) PAINT FROM BUILDING. PATCH ANY GOUGES OR
GAPS W/ TWO-PART WOOD-EPOXY. INFILL CRACKS W/
PAINT-READY SEALANT, SAND SURFACE UNTIL SMOOTH. HAND
APPLY SOLUTION TO KILL ANY MOLD OR MILDEW PRESENT, DO
NOT POWERWASH. APPLY CLEAR WATER REPELLANT W/
ANTI-MILDEW PROPERTIES. PAINT EXT W/ (1) COAT PRIMER, (2)
COATS TOP PAINT, INCLUDING WD SIDING, GABLE ENDS,
CORBELS, RAFTER TAILS, EAVES, TRIM, PLANTER BOXES,
COLUMNS, HAND RAILS, ACCESS DOORS, VENTS, AND
CONCRETE STEM WALLS, TYP. REINSTALL EXT SIGNAGE,
DOWNSPOUTS AND GUTTERS AT (E) LOCATIONS.
ENTIRE BUILDING: REMOVE (E) PAINT FROM (E) ELECTRICAL,
MECHANICAL, AND PLUMBING SYSTEMS EQUIPMENT
ATTACHED TO THE BUILDING, CLEAN AND PREP SURFACES.
APPLY (1) COAT PRIMER, (2) COATS LATEX PAINT. DO NOT
PAINT (N) EQUIPMENT.
FRONT PORCH: REPAIR/SECURE WD HANDRAIL.
REPAIR CONCRETE. REMOVE (E) AND/OR PREPARE CONCRETE
FOR POUR OR PATCH WORK. WHERE (E) CONCRETE TO
REMAIN, REMOVE DIRT AND VEGETATION. CLEAN AND STRIP
(E) PAINT FROM (E) SURFACE. STAIR AND LANDING
CONSTRUCTION TO COMPLY W/ 2021 IBC, SECTION 1101
REQUIRMENTS, TYP. PROVIDE PREFINISHED MTL FLASHING W/
DRIP EDGE WHERE CONCRETE ABUTS (E) SIDING FOR
POSITIVE DRAINAGE. PAINT ALL CONCRETE W/ (1) COAT
CONCRETE PRIMER, (2-3) COATS ELASTOMERIC (MASONRY)
PAINT.
ENSURE ATTIC VENT(S) PROVIDE VENTILATION AS REQUIRED
THROUGH CONSISTENT SCREEN/GRATE MATERIAL, REPLACE
AS REQUIRED AND/OR PROTECT (E) DURING EXT PAINTING
SCOPE.
REPAIR (E) FENCE, PAINT W/ (1) COAT PRIMER, (2) COATS TOP
PAINT.
DEMO AND REHAB KEYNOTES
1. (E) INFORMATION SHOWN ON DRAWINGS AND PHOTOGRAPHS
HAS BEEN TAKEN FROM LIMITED FIELD OBSERVATIONS. FIELD
VERIFY (E) CONDITIONS PRIOR TO BEGINNING WORK.
2. CORRECT AREAS AFFECTED BY INSTALLATIONS, MAINTAIN (E)
ACCESS AND OPERABILITY, TYP.
3. MATCH (E) EXT PAINT SCHEME W/ THE FOLLOWING:
DARK SHERWIN WILLIAMS DURATION EXT ACRYLIC SATIN
FRENCH ROAST SW 6069
LIGHT SHERWIN WILLIAMS DURATION EXT ACRYLIC SATIN
JERSEY CREAM SW 6379
4. (E) GUTTERS, DOWNSPOUTS, EXT SIGNAGE NOT SHOWN FOR
CLARITY.
GENERAL NOTES
SCALE OF FEET
SCALE OF FEET
4 4 4
4 4 4
2 3 3 2 22
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _A
R C
H .D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
NORTH AND SOUTH
ELEVATIONS
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
NORTH ELEVATION
SOUTH ELEVATION
1 1
51 11
9 1
A1.5
A1.5
SCALE OF FEET
SCALE OF FEET
REMOVE (E) SEALANT, FLASHING AND SIDING ADJACENT
TO (E) WINDOW, AS REQUIRED TO REMOVE (E) WINDOW,
FRAME, TRIM, AND ASSOCIATED COMPONENTS, TYP.
SALVAGE AND REUSE SIDING WHERE POSSIBLE.
SHIM (E) FRAMING AS NECESSARY, DO NOT CUT (E)
HEADER OR STUDS. INSTALL (N) WINDOWS IN (E) OPENING
AT SAME TOP ELEV, RE-TAPE/RE-APPLY WEATHER
BARRIER (IF PRESENT) FOR POSITIVE DRAINAGE. INSTALL
FRAMES, TRIM, BACKER ROD, SEALANT, FLASHING, AIR
SEAL TAPE AND ASSOCIATED COMPONENTS, TYP.
REATTACH SIDING TO MATCH ADJACENT FIELD OF (E)
MATERIAL/FINISH. IF DISCREPANCY, NOTIFY CO.
PROTECT (E) WINDOW SILLS AND INT FINISHES, TYP.
PATCH AND PAINT ANY DAMAGED INT DRYWALL AND
PLASTER CAUSED BY WINDOW REPLACEMENT/REPAIR TO
MATCH ADJACENT FIELD OF (E) MATERIAL/FINISH.
DEMO AND REHAB KEYNOTES
ENTIRE BUILDING: REMOVE (E) PAINT FROM (E)
ELECTRICAL, MECHANICAL, AND PLUMBING SYSTEMS
EQUIPMENT ATTACHED TO THE BUILDING, CLEAN
AND PREP SURFACES. APPLY (1) COAT PRIMER, (2)
COATS LATEX PAINT. DO NOT PAINT (N) EQUIPMENT.
FRONT PORCH: REPAIR/SECURE WD HANDRAIL.
REPAIR CONCRETE. REMOVE (E) AND/OR PREPARE
CONCRETE FOR POUR OR PATCH WORK. WHERE (E)
CONCRETE TO REMAIN, REMOVE DIRT AND
VEGETATION. CLEAN AND STRIP (E) PAINT FROM (E)
SURFACE. STAIR AND LANDING CONSTRUCTION TO
COMPLY W/ 2021 IBC, SECTION 1101 REQUIRMENTS,
TYP. PROVIDE PREFINISHED MTL FLASHING W/ DRIP
EDGE WHERE CONCRETE ABUTS (E) SIDING FOR
POSITIVE DRAINAGE. PAINT ALL CONCRETE W/ (1)
COAT CONCRETE PRIMER, (2-3) COATS ELASTOMERIC
(MASONRY) PAINT.
PATCH, SAND, VARNISH ANY DAMAGED (E) WINDOW SILL. INSTALL
CONT., COLOR-MATCH SEALANT AT WINDOW-TO-SILL INTERFACE.
REPAIR (E) WINDOW TO ENSURE OPERABILITY. IF UNABLE TO
REPAIR (E) WINDOW(S), REPLACE PER KEYNOTES 1-4.
ENTIRE BUILDING: REMOVE (E) EXT SIGNAGE, DOWNSPOUTS AND
GUTTERS AS NEEDED, STORE FOR REINSTALLATION. STRIP (E)
PAINT FROM BUILDING. PATCH ANY GOUGES OR GAPS W/
TWO-PART WOOD-EPOXY. INFILL CRACKS W/ PAINT-READY
SEALANT, SAND SURFACE UNTIL SMOOTH. HAND APPLY SOLUTION
TO KILL ANY MOLD OR MILDEW PRESENT, DO NOT POWERWASH.
APPLY CLEAR WATER REPELLANT W/ ANTI-MILDEW PROPERTIES.
PAINT EXT W/ (1) COAT PRIMER, (2) COATS TOP PAINT, INCLUDING
WD SIDING, GABLE ENDS, CORBELS, AWNINGS, RAFTER TAILS,
EAVES, TRIM, PLANTER BOXES, COLUMNS, HAND RAILS, ACCESS
DOORS, VENTS, AND CONCRETE STEM WALLS, TYP. REINSTALL
EXT SIGNAGE, DOWNSPOUTS AND GUTTERS AT (E) LOCATIONS.
ENSURE ATTIC VENT(S) PROVIDE VENTILATION AS REQUIRED THROUGH CONSISTENT SCREEN/GRATE
MATERIAL, REPLACE AS REQUIRED AND/OR PROTECT (E) DURING EXT PAINTING SCOPE.
REPAIR (E) FENCE, PAINT W/ (1) COAT PRIMER, (2) COATS TOP PAINT.
1. (E) INFORMATION SHOWN ON DRAWINGS AND PHOTOGRAPHS HAS BEEN TAKEN FROM LIMITED FIELD
OBSERVATIONS. FIELD VERIFY (E) CONDITIONS PRIOR TO BEGINNING WORK.
2. CORRECT AREAS AFFECTED BY INSTALLATIONS, MAINTAIN (E) ACCESS AND OPERABILITY, TYP.
3. MATCH (E) EXT PAINT SCHEME W/ THE FOLLOWING:
DARK - SHERWIN WILLIAMS DURATION EXTERIOR ACRYLIC SATIN FRENCH ROAST SW 6069
LIGHT - SHERWIN WILLIAMS DURATION EXTERIOR ACRYLIC SATIN JERSEY CREAM SW 6379
4. (E) GUTTERS, DOWNSPOUTS, EXT SIGNAGE NOT SHOWN FOR CLARITY.
GENERAL NOTES
10 10
A
ELECTRICAL LEGEND
OR
PH1
ME2.1
H
D I
F
B
H
S
D P
D T
TTB
S
M
V
W
MS
OS
E
G
AE
SDC
SSC
DELIVERED
6,119
MODEL
A
MANUFACTURER CRI
LITHONIA
REMARKS
LUMENS
TYPE
80+3500K
COLOR
TEMP
WATTS
49.9
6,119AX LITHONIA 80+3500K 49.9
SBL4-6000LM-80CRI-35K-MN10
GZT-MVOLT
SBL4-6000LM-80CRI-35K-MN10
GZT-MVOLT-E10WLCP
SQUARE BASKET 8.6"X48"X2.6", LED LUMINAIRE WITH ACRYLIC DIFFUSER,
DIMMING DRIVER
SQUARE BASKET 8.6"X48"X2.6", LED LUMINAIRE WITH ACRYLIC DIFFUSER,
DIMMING DRIVER
DIMMING
TYPE
0-10V, 10%-100%
0-10V, 10%-100%
VOLTS
FINISH
STANDARD
STANDARD
MOUNTING
SURFACE
SURFACE
X1 LITHONIA 120 WHITE- - - 1 SURFACETLE W 1R ELN EXIT SIGN, 11-7/8" X 7-3/4" X 7/8", LED, RED LETTERS, ONE FACE, WHITE HOUSING
W1 1201,080 5000K 70+ 11 SURFACETRL-ACEM-BR-CL
EXTERIOR EMERGENCY LUMINAIRE, 6.5" X 11.5" X 3.8", LED, COLD WEATHER
PACKAGE, BATTERY BACK UP, PHOTOCELL, DARK BRONZE HOUSING
PROVIDE W/ BATTERY BACKUP, PHOTOCELL, AND COLD LOCATION
PACKAGE.
G 120 WHITE SURFACE1,300SURFACE MOUNT DOWNLIGHT LED, 11" ROUND 3500K 90+ 15JUNO JSF-11IN 13LM-35K-90CRI
120 FRPC-WH
GX 120 WHITE SURFACE1,300SURFACE MOUNT DOWNLIGHT LED, 11" ROUND 3500K 90+ 15JUNO JSF-11IN 13LM-35K-90CRI
120 FRPC-WH-EL
120V
DRIVER
120V
DRIVER
L 120 WHITE SURFACE900LED KEYLESS LAMPHOLDER 3000K - 10LEVITON 000-09850-LED
B 120 WHITE SURFACE809WALL MOUNT 23.375"X3.875 X4.75, LED LUMINAIRE WITH ACRYLIC
DIFFUSER, DIMMING DRIVER, INTEGRAL OCCUPANCY SENSOR
3500K 90+ 7.5LITHONIA WL2-08L-EZB-LP835-NES7 120V
DRIVER
BARRON
LIGHTING GROUP
DESCRIPTION
DARK
BRONZE
W2 1205,075 SELECTABLE 80+ 35 SURFACEKT-FLED-R1B-UNV-8CSB-VDIM
EXTERIOR FLOOD LIGHT, 7.4" X 5.51" X 2.75", LED, 1/2" KNUCKLE, BRONZE
HOUSING, 4" ROUND FLOOD LIGHT JUNCTION COVER
PROVIDE W/ ROUND FLOOD LIGHT JUNCTION BOX COVER.0-10VKEYSTONE
TECHNOLOGIES
BRONZE
W3 1207,900 5000K - 56 POLEBGR LED P2 50K MVOLT PER DNA
EXTERIOR POLE LIGHT, 9.5" X 9.125" X 11.375", LED, GREY HOUSING WITH
MOUNTING ARM PROVIDE W/ MOUNTING ARM- GREYLITHONIA
WHERE WALL-MOUNTED, MATCH TYP MOUNTING HEIGHT
THROUGHOUT BLDG.
PROVIDE W/ BATTERY BACKUP. CENTER LIGHT FIXTURE ON
DOOR/OPENING, COORDINATE W/ DOOR SWING, WHERE OCCURS.
PROVIDE W/ BATTERY BACKUP.
PROVIDE W/ BATTERY BACKUP.
CENTER LIGHT FIXTURE ON SINK BELOW, TYP.
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _E
LE
C
.D W
G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
LEGEND, SCHEDULES,
AND
GENERAL NOTES
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
1. WORK INCLUDED IN THE CONTRACT IS DENOTED IN
BOLD. (E) CONDITIONS TO REMAIN ARE DENOTED
HALFTONE.
2. PROTECT (E) STRUCTURE AND EQUIPMENT FROM
DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO
ORIGINAL CONDITION, DAMAGE CAUSED UNDER
THIS CONTRACT.
3. (E) INFORMATION SHOWN ON DRAWINGS AND
PHOTOGRAPHS HAS BEEN TAKEN FROM LIMITED
FIELD OBSERVATIONS. FIELD VERIFY EXISTING
CONDITIONS PRIOR TO BEGINNING WORK.
4. DO NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY
SYSTEMS OR SERVICE W/O WRITTEN APPROVAL
FROM THE CO.
5. DEMOLITION/RENOVATION DRAWINGS MAY NOT
SHOW EVERY ITEM TO BE REMOVED. PRIOR TO
BEGINNING DEMOLITION/RENOVATION WORK,
VERIFY (E) CONDITIONS AND NOTIFY
CONTRACTING OFFICER OF ANY DISCREPANCIES.
6. REWORK (E) ELECTRICAL TO ACCEPT NEW WORK.
7. REMOVE ITEMS IN THEIR ENTIRETY BACK TO POINT
OF ORIGIN OR NEXT DEVICE TO REMAIN.
8. MAINTAIN CIRCUIT CONTINUITY TO (E) CIRCUITS
AND DEVICES TO REMAIN OR BE RELOCATED.
9. REMOVAL OF CONDUITS ROUTED IN CONCRETE
FLOOR SLABS, CONCRETE WALLS OR CONCRETE
CEILINGS: CUT BACK FLUSH W/ CONCRETE. FILL W/
GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH
FLUSH W/ CONCRETE SURFACE AFTER
CONDUCTORS HAVE BEEN REMOVED.
10. REMOVAL OF (E) DEVICES, SWITCHES, MOTOR
CONNECTIONS, ETC. FROM (E) WALLS TO REMAIN:
PATCH WALLS TO MATCH (E), ADJACENT FINISH.
INSTALL BLANK COVERPLATES TO MATCH (E) OVER
(E) BOXES, WHERE NOT REPLACED IN KIND, TYP.
11. REUSE (E) CONDUIT WHERE CURRENT NEC AND
LOCAL CODE REQUIREMENTS ARE MAINTAINED.
PROVIDE (N) CONDUIT AND WIRE FOR (N)
INSTALLATIONS AND EXTENSION OF (E)
INSTALLATIONS. REUSE (E) CONDUIT IN PLACE, DO
NOT REINSTALL EXISTING CONDUIT. LABEL
REUSED CONDUIT PER SPECIFICATIONS.
12. CLEAN RELOCATED EQUIPMENT AND DEVICES OF
ALL FOREIGN MATERIAL. REPLACE EQUIPMENT OR
DEVICES WHICH ARE DEFECTIVE OR DAMAGED
DURING RELOCATION.
GENERAL NOTES - ELECTRICAL
O
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _E
LE
C
.D W
G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
BASEMENT
ELECTRICAL
PLAN
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
BASEMENT ELECTRICAL PLAN
SCALE OF FEET
CL.
STORAGE ROOM
STORAGE
ROOM
OFFICE
CL.
UNEXCAVATED
WOOD
STORAGE
HALL
HEATER
ROOM
STORAGE
UNEXC.
OFFICE
UNEXCAVATED
PH3
E2.1
2PH4
E2.1
4 4
REMOVE (E) LIGHT, INSTALL (N) LIGHT AT SAME
LOCATION, TYP.
REMOVE (E) LIGHT W/ PULL STRING, INSTALL (N)
LIGHT AT SAME LOCATION. INSTALL
SURFACE-MOUNTED CONDUIT, CONDUCTORS AND
LIGHT SWITCH, RECESS INFRASTRUCTURE AND
COMPONENTS, WHERE POSSIBLE. CONNECT TO
LIGHT.
INSTALL EXIT LIGHT, CONNECT TO CIRCUIT PRIOR
TO SWITCHING, TYP. CENTER LIGHT FIXTURE ON
DOOR/OPENING, COORDINATE W/ DOOR SWING,
WHERE OCCURS.
REMOVE (E) 2' x 4' LIGHT. INSTALL (N) TYPE 'A' OR
'AX' LIGHT AT SAME LOCATION, WHERE OCCURS.
INSTALL OCCUPANCY SWITCH, ROUTE SURFACE
MOUNTED CONDUIT AND CONDUCTORS TO LIGHT.
REMOVE (E) FPE PANEL USED AS JUNCTION BOX.
INSTALL GUTTER AND JUNCTION BOXES AS
REQUIRED. EXTEND AND CONNECT CONDUITS AND
CONDUCTORS. CIRCUITS IN JUNCTION BOX ARE
FED FROM PANEL 'B'.
DEMO AND REHAB KEYNOTES
1. (E) INFORMATION SHOWN ON DRAWINGS AND
PHOTOGRAPHS HAS BEEN TAKEN FROM LIMITED
FIELD OBSERVATIONS. FIELD VERIFY (E) CONDITIONS
PRIOR TO BEGINNING WORK.
2. CORRECT AREAS AFFECTED BY INSTALLATIONS,
MAINTAIN (E) ACCESS AND OPERABILITY, TYP.
3. RECESS INFRASTRUCTURE AND COMPONENTS,
WHERE POSSIBLE.
4. WHERE INFRASTRUCTURE IS SURFACE-MOUNTED OR
EXPOSED, SUCH AS CONDUIT, PAINT TO MATCH
ADJACENT FIELD OF (E) MATERIAL/FINISH, TYP.
D
D
D D
D
3 3
DD
D
W2
D
W1 W1
W1
W1
W3
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _E
LE
C
.D W
G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATENO.
REVISION / ISSUE
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
GAOA - 6260183010602
FIRST FLOOR
ELECTRICAL
PLAN
CDI - TMICHAEL
CDI - KNATHE
12/2022
01/2022
100% - KNATHE
90% - TMICHAEL
FIRST FLOOR ELECTRICAL PLAN
PH1
E2.1
SCALE OF FEET
VISITOR
HALL/ELEC
LOBBY
CONFERENCE
SALES
HALL
RESTROOM
RESTROOM
HALL
LOBBY
109 KITCHENETTE
OFFICE
HALL
OFFICE
OFFICE
PORCH
CL.
PH2
E2.1
PH5
E2.1
PH7
E2.1
PH6
E2.1
1 REMOVE (E) LIGHT, INSTALL (N) LIGHT AT SAME
LOCATION, TYP.
REMOVE (E) LIGHT SWITCH, INSTALL (N) DIMMER
SWITCH AT SAME LOCATION, TYP.
INSTALL EXIT LIGHT, CONNECT TO CIRCUIT PRIOR
TO SWITCHING, TYP. CENTER LIGHT FIXTURE ON
DOOR/OPENING, COORDINATE W/ DOOR SWING,
WHERE OCCURS.
REMOVE (E) ELECTRICAL PANEL AND CIRCUIT
BREAKERS. INSTALL NEW 60A-2P PANEL W/ 12
SPACES AND COVER. INSTALL FOUR 20A-1P AND
ONE 25A-2P CIRCUIT BREAKERS. RECONNECT
EXISTING CIRCUITS. EXTEND SIX 1/2" SPARE
CONDUITS INTO ATTIC FOR FUTURE.
(E) MAIN SERVICE ENTRANCE PANEL AND METER
TO REMAIN.
REMOVE (E) EXT LIGHT, INSTALL (N) EMERGENCY
EGRESS LIGHT AT SAME LOCATION, TYP.
REMOVE (E) EXT FLOOD LIGHT, INSTALL (N) FLOOD
LIGHT. ADJUST ANGLE TO LIGHT FLAG.
REMOVE (E) EXT POLE LIGHT AND MOUNTING ARM,
INSTALL (N) POLE LIGHT AND MOUNTING ARM ON
(E) POLE.
DEMO AND REHAB KEYNOTES
1. (E) INFORMATION SHOWN ON DRAWINGS AND
PHOTOGRAPHS HAS BEEN TAKEN FROM LIMITED
FIELD OBSERVATIONS. FIELD VERIFY (E) CONDITIONS
PRIOR TO BEGINNING WORK.
2. CORRECT AREAS AFFECTED BY INSTALLATIONS,
MAINTAIN (E) ACCESS AND OPERABILITY, TYP.
3. RECESS INFRASTRUCTURE AND COMPONENTS,
WHERE POSSIBLE.
4. WHERE INFRASTRUCTURE IS SURFACE-MOUNTED OR
EXPOSED, SUCH AS CONDUIT, PAINT TO MATCH
ADJACENT FIELD OF (E) MATERIAL/FINISH, TYP.
GENERAL NOTES
CENTER LIGHT
FIXTURE ON SINK
BELOW
ROOM 101 AND 102 LIGHTSPH1
E1.1
CLOSET LIGHTPH3
E1.0
ELECTRICAL PANEL CPH4
E1.0
ELECTRICAL PANEL APH2
E1.1
EXTERIOR LIGHTPH5
E1.1
/2
9/
4:
K
O D
YN
AT
H E
C :\U
SE
R
S\
KO
D
YN
AT
H
E\
BO
X\ C
D I\R
IO
G
\B
LD
G S\
C R
EE
D
E\ D
IS
TR
IC
TO
FF
IC
E\
R
EH
AB
\0
C
AD
\C O
_R
IO
G
C R
EE
D
E D
O _E
LE
C
P H
O
TO
S.
D
W G
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
CREEDE OFFICE
UPGRADES
RIO GRANDE
NATIONAL FOREST
DIVIDE RANGER
DISTRICT
12/2022 12
R2
ROCKY MOUNTAIN
REGION
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
DATENO. REVISION / ISSUE
GAOA - 6260183010602
PHOTOGRAPHS
CDI - TMICHAEL
CDI - KNATHE
90% - TMICHAEL 01/2022
100% - KNATHE 12/2022
FLAG FLOOD LIGHTPH6
E1.1
POLE LIGHTPH7
E1.1
1 REMOVE (E) LIGHT, INSTALL (N) LIGHT AT SAME
LOCATION, TYP.
REMOVE (E) LIGHT SWITCH, INSTALL (N) DIMMER
SWITCH AT SAME LOCATION, TYP.
APPROXIMATE LOCATION OF (N) EXIT LIGHT.
REMOVE (E) ELECTRICAL PANEL, INSTALL (N) PANEL
AT SAME LOCATION W/ COVER.
REMOVE (E) LIGHT, INSTALL (N) LIGHT AT SAME
LOCATION. INSTALL LIGHT SWITCH, SURFACE
MOUNTED CONDUIT AND CONDUCTORS.
REMOVE (E) ELECTRICAL PANEL, INSTALL GUTTER
IN SAME LOCATION.
DEMO AND REHAB KEYNOTES
1. (E) INFORMATION SHOWN ON DRAWINGS AND
PHOTOGRAPHS HAS BEEN TAKEN FROM LIMITED
FIELD OBSERVATIONS. FIELD VERIFY (E)
CONDITIONS PRIOR TO BEGINNING WORK.
2. CORRECT AREAS AFFECTED BY INSTALLATIONS,
MAINTAIN (E) ACCESS AND OPERABILITY, TYP.
3. RECESS INFRASTRUCTURE AND COMPONENTS,
WHERE POSSIBLE.
4. WHERE INFRASTRUCTURE IS SURFACE-MOUNTED
OR EXPOSED, SUCH AS CONDUIT, PAINT TO MATCH
ADJACENT FIELD OF (E) MATERIAL/FINISH, TYP.
| 2023-01-03T15:16:41-0700 | |
| SHEILA CROSS |
| 2023-01-04T06:56:26-0700 | |
| DOUGLAS WISE |