Attachment 3 combine - Tranche 1 Villa 10.pdf
PDF 1 MB Posted
- Attached to
- 19M05522Q0010 Installation of Security Upgrades
- Solicitation number
- 561621
- Issued by
-
Department of State
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GSPublisherVersion 0.3.100.100
Do not scale. All dimensions to be checked on site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_600(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Grilles de pergola - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
T1/V10
'U' en acier, 20x40 mm Galvanisé
Tube carré en acier 20x20 mm Galvanisé
Paumelles
Fer plat en acier Galvanisé pattes de scellement
Quincaillerie : Serrures, poignées et loqueteaux. Acier galvanisé
Tôle perforée (Galvanisé si acier)
Couleur de peinture : Blanc pur RAL 9010
LÉGENDE
Fer plat en acier
A - A F - F
COUPE DETAILÉE
Tube carré en acier, 20x20
'U' en acier, 40x20 'U' en acier, 40x20
Tube carré en acier, 20x20
Paumelles 140mm
B - B
'U' en acier, 40x20 Fer plat en acier
Ligne de tube carré en acier, 20x20
2, 310 4,710
2, 2, 3104,710
1, 1, 2, 2, 2, 1, G3
G4 fer plat on acier monté côté escalier
100mm
100mm
TRANCHE 1 - VILLA 10
FENÊTRE
A
A
B B Paumelles montées côté pergola
La porte pivote en direction de la pergola
20x20
F
F
PE
R
G O
LA
O
U
VE
R
TE
S U
R L
A
VO
IE
IN
TÉ
R
IE
U
R D
U G
R O
U
PE
M
EN
T
OUVERTE AU JARDIN DE LA MÊME PARCELLE
OUVERTE AU JARDIN DE LA MÊME PARCELLE
PE
R
G O
LA
O
U
VE
R
TE
S U
R L
A
VO
IE
IN
TÉ
R
IE
U
R D
U G
R O
U
PE
M
EN
T
40x20 'U' en acier
20x20 Tube carré en acier pattes de scellement
40x20 'U' en acier pattes de scellement
Tube carré en acier
Façade proposée: a'-a'
Façade proposée: b'-b' b' b' a' a'
24 Mai 22
ND
1:50 site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_601(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Mur de Clôture en Maçonnerie - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
Réception
Piscine
Pergola
Terrasse
Jardin
Entr ée
Cuisine
Cour
Cage d'escaliers
Toilette
Séjour
Coin fe u
Entrée
Jardin
T138699/38
Villa9 S/Sol+Rdc+1étage
Niveau Consistances
TABLEAU DES CONTENANCES
Villa
Cour
Piscine
Contenance
2 10 A Ca
0 22 A Ca
0 27 A Ca
TerrasseRDC 0 44 A Ca
Pergola 0 30 A Ca
Jardin et Escaliers 4 59 A Ca
Total 7 92 A Ca
Vers 1er étage
Local technique
Total 3 33 A Ca
365110
365120
365130
365140
A
A
Con du ite G
AZODUC Exis tan te (L= m)
Lo t A
P.F
P.F
R
OUTE PRIN
CIPALE
no
.22 , 6
0m
VOIE IN
TÉRIEUR D
E LO
TISSEMENT,
Tra nc he 1, 8m
Mur nécessitant surélévation de poteau and barreaudage = 50.2m longueur totale
LÉGENDE
bambou existante
MUR D
E M
AÇONNERIE à mm et mm au -de ss us du ni ve au du ja rdi n ( va ria ble
MUR D
E M
AÇONNERIE à m m et m m au -de ss us du ni ve au du so l a dja ce nt
(va ria ble
MUR DE MAÇONNERIE à 1300mm et 1600mm au-dessus du niveau du jardin (variable) MUR DE MAÇONNERIE à 670 mm et 970 mm au-dessus du niveau du sol adjacent (variable)
MUR DE MAÇONNERIE à 1200mm et 1500mm au-dessus du niveau du jardin (variable)
MUR DE MAÇONNERIE à 1370 mm et 1670 mm au-dessus du niveau du sol adjacent (variable)
MUR DE MAÇONNERIE à 1200mm et 1500mm au-dessus du niveau du jardin (variable)
MUR DE MAÇONNERIE à 2220 mm et 2520 mm au-dessus du niveau du sol adjacent (variable)
PROPRIÉTÉ AVOISINANTE SOUS DIFFÉRENTS PROPRIÉTAIRES
VOIE INTÉRIEUR DE LOTISSEMENT, 12m
2, 2, 2, 2, 2, 2, 2, 7,800 20,023 7,175 6,710 5,191
2, 2, 2, 2, 2, 1, 1, 1, Variation sur la longueur du périmètre. Les longueurs sont approximatives et doivent correspondre aux créneaux. A vérifier sur place avant fabrication.
1, 1, 1, 1, 2, 2, Le niveau du sol extérieur adjacent varie considérablement dans cette villa et nous suggérons cinq hauteurs de clôture différentes sur ce périmètre. Veuillez consulter la schéma ci-dessous pour les hauteurs approximatives.
le point le plus élevé du barreaudage doit être à au moins 2m au-dessus du niveau du sol lorsqu'il est mesuré du côté extérieur de la propriété. A vérifier sur place avant fabrication.
niveau du sol adjacent varie entre
+0.93m à -0.92m +0mm niveau du jardin 60
LÉGENDE
Barreaudage en acier, sections de 30x50mm et 50x50mm (variable): Galvanisé, blanc pur RAL 9010
Section carrée en acier, 50x50mm: Galvanisé, blanc pur RAL 9010 pattes de scellements encastrées, barre plate en acier. Galvanisé, blanc pur RAL 9010
Barreaudage en acier galvanisé : Sections de 30 x 50 mm et 50 x 50 mm.
Galvanisé, blanc pur RAL 9010
Section carrée en acier, 50 x 50mm Galvanisé, blanc pur RAL 9010 pattes de scellements encastrées, barre plate en acier.
Galvanisé, blanc pur RAL 9010
10mm écart de drainage sous l'acier les barreaudages doivent être montées au ras du côté extérieur de la propriété tête inclinée
La largeur des traverses du barreaudage varie entre:
30 et 50mm
Les écarts entre les traverses du barreaudage varient entre:
50 et 100mm
50 100
100 30 va rie s va rie s va rie s va rie s
+ 1600mm tête de mur indicative niveau du sol adjacent varie entre +0.93m à -0.92m
+0mm niveau du sol du jardin indicatif
+ 1300mm tête de mur indicative
+ 2000mm haut des poteaux de extérieur de la parcelle
Barreaudage en acier: Sections de 30 x 50 mm et 50 x 50 mm.
Galvanisé, blanc pur RAL 9010
Tube carrée en acier, 50 x 50mm Galvanisé, blanc pur RAL 9010 pattes de scellements encastrées, barre plate en acier Galvanisé, blanc pur RAL 9010 dimensions indicatives
10mm écart de drainage sous l'acier
24 Mai 22
ND
Détail de la façade, 1:20
Détail, 1:10 Façade partielle (côté jardin), 1:50
Façade indicative (côté jardin) montrant cinq hauteurs de clôture suggérées. Hors l'échelle.
site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_602(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Clôture Métallique - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
Posts requiring extension (13 no.)
Posts not requiring extension (13 no.)
LEGEND
New fence Installation (2m high) = 28.7m total length
Planting proposed = 30.3m total length
Fabric privacy mesh proposed = 15.8m total length
New fence Installation (1.54m high) = 18.6m total length
Réception
Piscine
Pergola
Terrasse
Jardin
Entr ée
Cuisine
Cour
Cage d'escaliers
Toilette
Séjour
Coin fe u
Entrée
Jardin
T138699/38
Villa9 S/Sol+Rdc+1étage
Niveau Consistances
TABLEAU DES CONTENANCES
Villa
Cour
Piscine
Contenance
2 10 A Ca
0 22 A Ca
0 27 A Ca
TerrasseRDC 0 44 A Ca
Pergola 0 30 A Ca
Jardin et Escaliers 4 59 A Ca
Total 7 92 A Ca
NPLAN DU REZ DE CHAUSSEE
TR1-VILLA10
Vers 1er étage
Local technique
Total 3 33 A Ca
365110
365120
365130
365140
A
A
Con du ite G
AZODUC Exis tan te (L= m)
Lo t A
P.F
P.F
R
OUTE PRIN
CIPALE
no
.22 , 6
0m
VOIE IN
TÉRIEUR D
E LO
TISSEMENT,
Tra nc he 1, 8m
PROPRIÉTÉ AVOISINANTE SOUS DIFFÉRENTS PROPRIÉTAIRES
VOIE INTÉRIEUR DE LOTISSEMENT, 12m
Poteaux qui nécessitent surélévation (13 U.)
Poteaux qui ne nécessitent pas surélévation (13 U.)
LÉGENDE
Installation d'un nouveau barreaudage (2m de ht.) = 28,7 m de longueur totale
Plantation proposée = 30,3 m de longueur totale brise-vue proposée, en polyéthylène ultra résistant = 15,8 m de long. totale
Installation d'un nouveau barreaudage (1,54 m de ht.) = 18,6 m de long. tot.
2, 1, 1, 1, 1, 1, 100mm 100mm
État de la clôture existante poteau en acier: 60 x 60mm section carrée, Galvanisé, vert
Nouvelle clôture avec surélévation de poteau
Pince de clôture, acier galvanisé, vissé
Clôture grillagée Galvanisé, vert bouchon de poteau, plastique, vert poteau encastré dans une fondation en béton
Extension de poteau
« Sabot » en métal pour gainer la tête de poteau existante, boulonné en position. Poteau identique à monter par dessus cornière en acier: 60 x 60mm Galvanisé, vert barre plate en acier, boulonné à l'angle en acier :
Galvanisé, vert fer carré en acier: 15 x 15mm tête coudée (pointe) Galvanisé, vert
Nouvelle clôture sans surélévation requise bouchon de poteau, plastique, vert
« Sabot » en métal pour gainer la tête de poteau existante, boulonné en position.
cornière en acier: 60 x 60mm boulonné à poteau existant Galvanisé, vert
Fer plat en acier, boulonné à l'angle en acier :
Galvanisé, vert poteau en acier: 60 x 60mm section carrée, Galvanisé, vert bouchon de poteau, plastique, vert fer carré en acier: 15 x 15mm tête coudée (pointe) Galvanisé, vert
24 Mai 22
ND
DÉTAIL PROPOSÉ, 1:10
site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_603(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Clôture de la Piscine - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
257 847 2,928 1,055
2,161
7,199 1,000
Réception
Piscine
Terrasse
Local technique
P.F
La porte coulissante nécessite des grilles fixes à cet endroit
1, 1, 20x20mm Tube carré en acier inoxydable, 50 x 50 mm cornière en acier inoxydable fer plate en acier
A
6.6.2 (11mm) verre feuilleté
Angles de scellement en acier inoxydable
6.6.2
Verrouillage de la barrière de sécurité de la piscine et des enfants à 1372 mm au-dessus du niveau du sol, minimum
Paumelles
LÉGENDE
fer plat en acier inoxydable, 5 x 20 mm verre feuilleté, 6.6.2 (11mm) verre feuilleté Tube carré en acier inoxydable, 50 x 50 mm
Tube carré en acier inoxydable, 50 x 50 mm cornière en acier inoxydable
Tube carré en acier inoxydable, 50 x 50 mm cornière en acier inoxydable, 20 x 20 mm
Entrée dans la clôture de la piscine
LÉGENDE
Ligne de clôture de piscine, haut. 1,22m min.
24 Mai 22
ND
DÉTAIL PROPOSÉ, hors échelle
PLAN PROPOSÉ, 1:100
Verrouillage de la barrière de sécurité de la piscine et des enfants à 1372 mm au-dessus du niveau du sol, minimum.
site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_604(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Grilles de Securité 01:
Fenêtres et Portes - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
T1V10
WG01
T1V10
WG02
T1V10
WG03
T1V10
WG04
T1V10
WG05
T1V10
WG06
T1V10
WG07
T1V10
WG08
T1V10
WG09
T1V10
WG10
T1V10
WG11
T1V10
WG12 T1V10
WG13
T1V10
WG14
Aération
FAÇADE LATERALE GAUCHE
FAÇADE ARRIÈRE
FAÇADE LATERALE DROITE
FAÇADE PRINCIPALE
LÉGENDE
Pattes de scellement
* Toutes les serrures doivent être entourées d'une barrière de protection en acier galvanisé de 5 cm
'U' en acier, 20x40 mm Galvanisé
Fer carré en acier 20x20 mm Galvanisé
Paumelles
Fer plat en acier Galvanisé
Quincaillerie : Serrures, poignées et loqueteaux. Acier galvanisé
Tôle perforée (Galvanisé si acier)
Couleur de peinture : Blanc pur RAL 9010
24 Mai 22 site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_605(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Grilles de Securité 02:
Fenêtres et Portes - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
LÉGENDE
Pattes de scellement
* Toutes les serrures doivent être entourées d'une barrière de protection en acier galvanisé de 5 cm
'U' en acier, 20x40 mm Galvanisé
Fer carré en acier 20x20 mm Galvanisé
Paumelles
Fer plat en acier Galvanisé
Quincaillerie : Serrures, poignées et loqueteaux. Acier galvanisé
Tôle perforée (Galvanisé si acier)
Couleur de peinture : Blanc pur RAL 9010
COUPES DÉTAILLÉES
Paumelles 140mm
'U' en acier 20x40
Fer carré en acier 20x20 fer plat en acier
Ligne de fer carré en acier 20x20
Paumelles 140mm
Paumelles 140mm
Fer carré en acier 20x20
'U' en acier 20x40 fer plat en acier
'U' en acier 20x40 fer plat en acier fer plat en acier'U' en acier 20x40
Ligne de fer carré en acier 20x20
A - A B - B
D - D
C - C
2,000 580 3,000
1, 1, 1, 2,980
3,460
1, 2, 3,950 3,310
2, 2, T1V10
WG03
T1V10
WG04
T1V10
WG06
T1V10
WG05
T1V10
WG07
T1V10
WG08
T1V10 WG01 et WG02
A
A
100mm
20x20 40x20
A
A
100mm
20x20
40x20A
A
100mm
20x20
40x20
A
A
100mm
20x20 40x20
B
B
100mm
C C
20x20 40x20
A
100mm
20x20 40x20
A
20x20 40x20
A
100mm
A pattes de scellement
Fer carré en acier
'U' en acier
LoqueteauxPaumelles
Fer carré en acier
'U' en acier
'U' en acierFer carré en acier pattes de scellement pattes de scellement
Fer carré en acier 'U' en acier pattes de scellement pattes de scellement
Fer carré en acier 'U' en acier
Fer carré en acier 'U' en acier pattes de scellement
Fer carré en acier 'U' en acier pattes de scellement 24 Mai 22 site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_606(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Grilles de Securité 03:
Fenêtres et Portes - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
LÉGENDE
Pattes de scellement
* Toutes les serrures doivent être entourées d'une barrière de protection en acier galvanisé de 5 cm
'U' en acier, 20x40 mm Galvanisé
Fer carré en acier 20x20 mm Galvanisé
Paumelles
Fer plat en acier Galvanisé
Quincaillerie : Serrures, poignées et loqueteaux. Acier galvanisé
Tôle perforée (Galvanisé si acier)
Couleur de peinture : Blanc pur RAL 9010
COUPES DÉTAILLÉES
Paumelles 140mm
'U' en acier 20x40
Fer carré en acier 20x20 fer plat en acier
Ligne de fer carré en acier 20x20
Paumelles 140mm
Paumelles 140mm
Fer carré en acier 20x20
'U' en acier 20x40 fer plat en acier
'U' en acier 20x40 fer plat en acier fer plat en acier'U' en acier 20x40
Ligne de fer carré en acier 20x20
A - A B - B
D - D
C - C
3,960
2, 2, 770 72
1,920 65
T1V10
WG09
T1V10
WG10
T1V10
WG11
T1V10
WG14
T1V10
WG12
T1V10
WG13
A
A
20x20
40x20 B
B
100mm
D D
20x20
40x20
100mm
A
A
100mm
20x20 40x20
20x20 20x20 20x20
100mm 100mm
A
A
A
A A
A pattes de scellement pattes de scellement
Fer carré en acier
'U' en acier
Fer carré en acier
'U' en acier
Paumelles pattes de scellement
Fer carré en acier 'U' en acier
Fer carré en acier
40x20 'U' en acier pattes de scellement pattes de scellement pattes de scellement
40x20 'U' en acier
Fer carré en acier Fer carré en acier
40x20 'U' en acier
1,160 100mm
24 Mai 22 site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_607(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Séparation en Tôle Galvanisé - Tranche 1 Villa
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
30 40 30
1,047
1, A - A
A
A
A A joint soudé Pattes de scellement
Couleur de peinture : Blanc pur RAL 9010
* ouvertures 10 x 80 mm, espacées de 20 mm dans chaque direction
Tôle métallique galvanisé, perforée découpée au laser.
DÉTAIL
LÉGENDE
'U' en acier, 20x40
Pattes de scellement tôle métallique galvanisé, perforée découpée au laser
Tôle métallique galvanisé, perforée découpée au laser.
Les ouvertures ne doivent pas dépasser 10 mm de hauteur.
'U' en acier, 20x40 mm.
Galvanisé
Pattes de scellement
'U' en acier, 20x40 2, Aération Réserve
REAR FACADE
RIGHT SIDE FACADE
Terrasse
TerrasseTerrasse
Jardin
Terrasse
Terrasse
Suite Parentale 'Pièce Sécurisée'
Chambre pl.
pl.
24 Mai 22 site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_608(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Niche pour Bouteilles de Propanes - Tranche 1 Villa
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
120 900 130
1, 1, 1,200
LÉGENDE
Plan Coupe a' - a' Plan d'en haut
Façade Coupe b' - b'
Plaque en acier inoxydable avec boulon verrouillable
Boulon béton armé, peinture blanc
Carreaux a' a' b' b'
A A
Paumelles 140mmA - A Barre en acier, forme 'U' 20x40
Support de boulon en tôle d'acier
DÉTAIL
Vantaux: voir détail A-A
Carreaux (comme les carreaux de sol existants)
Socle en béton armé lissé parois en brique 8 trous, enduit, peinture blanc
Toiture en carreaux sur béton armé, peinture blanc
Connexion à travers le mur au-dessus des bouteilles
'U' en acier 20x40 mm Galvanisé
Paumelles
Fer plat en acier Galvanisé
Pattes de scellement
Quincaillerie : Serrures, poignées et loqueteaux. Acier galvanisé
Couleur de peinture : Blanc pur RAL 9010
Carreaux
Pattes de scellement
Barre plate en acier tôle métallique galvanisé, perforée découpée au laser tôle métallique galvanisé, perforée découpée au laser tôle métallique galvanisé, perforée découpée au laser tôle métallique galvanisé, perforée découpée au laser parois en brique de 8 trous, enduit, peint en blanc
Socle en béton armé lissé
'U' en acier 20x40
Paumelles
Socle en béton armé lissé parois en brique 8 trous, enduit, peinture blanc béton armé, peinture blanc
'U' en acier 20x40
Connexion à travers le mur au-dessus des bouteilles
1,150
Entrée
A
Cuisine
Cour escalier
24 Mai 22
ND
Plan de Situation site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_609(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Éclairage Extérieur - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
Aération Chaudière
Aération Réserve
2 31 4 5
6 7
8 8
FAÇADE ARRIÈRE
FAÇADE LATERALE DROITE
FAÇADE LATERALE GAUCHE
FAÇADE PRINCIPALE
Réception
Piscine
Pergola
Terrasse
Jardin
Entr ée
Cuisine
Cour
Cage d'escaliers
Toilette
Séjour
Coin fe u
Entrée
Jardin
T138699/38
Villa9 S/Sol+Rdc+1étage
Niveau Consistances
TABLEAU DES CONTENANCES
Villa
Cour
Piscine
Contenance
2 10 A Ca
0 22 A Ca
0 27 A Ca
TerrasseRDC 0 44 A Ca
Pergola 0 30 A Ca
Jardin et Escaliers 4 59 A Ca
Total 7 92 A Ca
PLAN DU REZ DE CHAUSSEE
TR1-VILLA10
Vers 1er étage
Local technique
Total 3 33 A Ca
365110
365120
365130
365140
A
A
Con du ite G
AZODUC Exis tan te (L= m)
Lo t A
P.F
P.F
N nouveau circuit d'éclairage
R
OUTE PRIN
CIPALE
no
.22 , 6
0m
VOIE IN
TÉRIEUR D
E LO
TISSEMENT,
Tra nc he 1, 8m
VOIE INTÉRIEUR DE LOTISSEMENT, 12m
PROPRIÉTÉ AVOISINANTE SOUS DIFFÉRENTS PROPRIÉTAIRES
Projecteur LED solaire extérieur avec détecteur de mouvement, étanche (10 u.)
LÉGENDE
Maintenir le projecteur existant avec l'ajout d'un dispositif de détection de mouvement (1 u.)
Cable U1000R2V 3x2.5mm2
24 Mai 22 site prior to commencement of work
DRAWING NO:
CHECKED BY:
SCALE: DATE:
REV:
DRAWN BY:
#Pln/A.06
1:1
DRAWING TITLE
Layout
JOB TITLE
#Project Name for #Client Company
38 New City Road Glasgow - G4 9JT 0141 352 6929 info@jawarchitects.co.uk www.jawarchitects.co.uk
Jewitt and Wilkie architects
Des ign{ } N A O M I D A H H A N
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
DAHHAN DESIGN
D es ig n } N
A O
M I
D A
H H
A N
A R C H
IT
EC
TU
R A L C O N
SU
LT
A N T
A N D D
ES
IG
N
ER
D A H H A N D E S
IG
N G M A
IL
.C O M
R A B A T, M O R O C C O
Ne pas mettre à l'échelle. Toutes les dimensions doivent être vérifiées en chantier avant le début des travaux.
RÉVISIONS
PROJET
TITRE DU DESSIN
1029/L_T1V10_610(fr)
Maison Indigo III - Phase 1 pour L'Ambassade Américaine
Mur d'Entrée et Portails - Tranche 1 Villa 10
No DE DESSIN:
VÉRIFIÉ PAR:
ÉCHELLE: DATE:
RÉV:
DESSINÉ PAR:
0 34
1,230 1,076 1,040
760 320
0 34
1,230 1,076 1,040
760 320
1, 2, 1,230 1,076 1,040
1, 1, D: 0.795 x 1.585m
Pl. Pl.D: 1.04 x 1.21m
D: 0.795 x 1.585m
D: 1.04 x 1.985m pilier non modifié voir dessin T1V10_602 pour la clôture
Façade: Existante
Plan: Proposé
Façade: Proposée
Tube carré en acier, galvanisé 40 x 40 mm
Tôle galvanisée, 4mm ép.
Supports encastrés et paumelles pour accrocher le vantail de la porte
Cornière en acier inoxydable ou galvanisé 15 x 15 mml
Couronnement du mur revêtu de pierre
A
A
A
A A - A
Portail de l'Extérieur
Structure du Portail Intérieur
Tôle galvanisée
Tube carré en acier 40 x 40mm cornière 15x15mm verre feuilleté dépoli supports encastrés
LED Solaire
LÉGENDE
cornière en acier inoxydable (portail piéton) 20x 50mm
Fer plat en acier, Galvanisé verre feuilleté dépoli, 5.5.2
Couleur de peinture : Blanc pur RAL 9010
Tôle galvanisée verre feuilleté dépoli
Tube carré en acier 40 x 40mm
Couronnement du mur revêtues de pierre
Plan: Existant
LED Solaire pilier non modifié
24 Mai 22
| L_T1V10_600(fr) Grilles de pergola - Tranche 1 Villa 10 |
| L_T1V10_600(fr) Grilles de pergola - Tranche 1 Villa 10 |
| L_T1V10_601(fr) Mur de Clôture en Maçonnerie - Tranche 1 Villa 10 |
| L_T1V10_601(fr) Mur de Clôture en Maçonnerie - Tranche 1 Villa 10 |
| L_T1V10_602(fr) Clôture Métallique - Tranche 1 Villa 10 |
| L_T1V10_602(fr) Clôture Métallique - Tranche 1 Villa 10 |
| L_T1V10_603(fr) Clôture de la Piscine - Tranche 1 Villa 10 |
| L_T1V10_603(fr) Clôture de la Piscine - Tranche 1 Villa 10 |
| L_T1V10_604(fr) Grilles de Securité 01_ Fenêtres et Portes - Tranche 1 Villa 10 |
| L_T1V10_604(fr) Grilles de Securité 01: Fenêtres et Portes - Tranche 1 Villa 10 |
| L_T1V10_605(fr) Grilles de Securité 02_ Fenêtres et Portes - Tranche 1 Villa 10 |
| L_T1V10_605(fr) Grilles de Securité 02: Fenêtres et Portes - Tranche 1 Villa 10 |
| L_T1V10_606(fr) Grilles de Securité 03_ Fenêtres et Portes - Tranche 1 Villa 10 |
| L_T1V10_606(fr) Grilles de Securité 03: Fenêtres et Portes - Tranche 1 Villa 10 |
| L_T1V10_607(fr) Séparation en Tôle Galvanisé - Tranche 1 Villa 10 |
| L_T1V10_607(fr) Séparation en Tôle Galvanisé - Tranche 1 Villa 10 |
| L_T1V10_608(fr) Niche pour Bouteilles de Propanes - Tranche 1 Villa 10 |
| L_T1V10_608(fr) Niche pour Bouteilles de Propanes - Tranche 1 Villa 10 |
| L_T1V10_609(fr) Éclairage Extérieur - Tranche 1 Villa 10 |
| L_T1V10_609(fr) Éclairage Extérieur - Tranche 1 Villa 10 |
| L_T1V10_610(fr) Mur d'Entrée et Portails - Tranche 1 Villa 10 |
| L_T1V10_610(fr) Mur d'Entrée et Portails - Tranche 1 Villa 10 |
File details come from the government source that posted it. Updated .