This is a technical specification document from the Colorado Inactive Mine Reclamation Program detailing the design and installation requirements for a bat cupola shaft grating system. The document specifies the construction of a shaft grate alternative featuring a bat cupola structure designed to accommodate bat populations while securing inactive mine shafts. The grating specifications include 1 1/4" x 3/16" bearing bars spaced at 1 3/16" on center with 1/4" round cross rods spaced at 4" on center, type WXA (19-4-53), with cross rods positioned on the inside of the grate frame. The cupola frame construction requires 2"x2"x 1/4" angle material, and the opening in the shaft grate must be framed with matching 2"x2"x 1/4" angle. The bat cupola shall extend a minimum of 24 inches above the shaft grating and be welded to the framed opening. The document includes side view and plan view technical drawings illustrating the proper assembly and positioning of all components relative to the 6" shaft grating.
No information regarding pricing, bidding timelines, contract terms, funding sources, or procurement procedures is contained within this technical specification document. This file functions solely as a design guide for contractors and engineers implementing shaft grating and bat cupola installations under Colorado's Inactive Mine Reclamation Program.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 3
Shaft Grate with Bat Alternative
Bat Cupola
Grating (1
"x
" bearing bars @ 1
" O.C., " round cross rods @ 4" O.C., type WXA
(19-4-53); tack weld every other bearing bar to grate frame; cross rod side inside.
∠2"x2"x cupola frame
6" shaft grating
Colorado Inactive Mine Reclamation Program
Bat Cupola Drawing
SIDE VIEW
PLAN VIEW
SIDE VIEW
∠2"x2"x cupola frame
Opening in shaft grate shall be framed with 2"x2"x
" angle. Bat cupola shall stick up above and be welded to framed opening.
shaft grating
6" maximum cupola grating cupola grating cupola grating
∠2"x2"x
24" minimum
∠2"x2"x opening frame
∠2"x2"x opening frame
∠2"x2"x opening frame