Attachment 3 - Asbestos Testing Report.pdf

PDF 8 MB Posted

Attached to
FA4613 - B34 2nd/3rd Floor Carpet Federal contract opportunity
Solicitation number
FA461325Q0012
Issued by
Department of the Air Force Global Strike Command

About this file

The document is an Asbestos Testing Report for Building 34 at F.E. Warren Air Force Base in Cheyenne, Wyoming, conducted by Asbestos & Technical Services, Inc. on April 25, 2024. The comprehensive inspection involved taking 40 total samples across the 1st, 2nd, and 3rd floors, examining various materials including vinyl cove bases, carpet, drywall, floor sealants, glue, and concrete surfaces. Critically, the report conclusively found no asbestos-containing materials (ACM) in any of the samples tested, which is significant for the related carpet replacement solicitation (FA461325Q0012) for the Security Forces Group building.

The testing report was prepared using EPA and OSHA guidelines, with samples analyzed through polarized light microscopy at CA Labs. The inspection methodology included non-destructive sampling protocols and followed industry standards for identifying potentially hazardous materials. The report emphasizes that while the inspection was thorough, it cannot guarantee absolute elimination of all potential asbestos-containing materials, and recommends stopping work and testing any newly discovered suspect materials during future renovation or demolition activities.

View the file

Other files for this federal contract opportunity

Other files attached to FA4613 - B34 2nd/3rd Floor Carpet, newest first.
File Type Posted
SF 30 - FA461325Q00120004.pdf PDF
SF 30 - FA461325Q00120003.pdf PDF
Attachment 6 - Post Site Visit Questions and Answers.pdf PDF
Attachment 7 - Brand Name or Equal JA (Redacted).pdf PDF
SF 30 - FA461325Q00120001.pdf PDF
Attachment 5 - Hazmat Auth Request.pdf PDF
Attchment 2 - B34 Drawings.pdf PDF
Solicitation - FA461325Q0012.pdf PDF
Attachment 1 - Performance Work Statement 03 Feb 25.pdf PDF
Attachment 4 - Salient Characteristics.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos & Technical Services, Inc P.O. Box 2574

Cheyenne, WY 82003

307-214-0904

Asbestos & Lead Inspection Report

April 30, 2024

Chris Carter

Project: FE Warren AFB, Building 34 (1st Floor, 2nd Floor, Attic -Carpet Replacement)

Cheyenne, WY 82001

Dear Mr. Carter, On April 25, 2024, ATS performed an asbestos inspection of the above-mentioned project. The purpose of the survey is to identify asbestos containing material (ACM) using nondestructive sampling protocols.

Inspection, sampling and analytical procedures were performed in general accordance with the Environmental Protection

Agency’s (EPA) interpretations, and guidelines of the Asbestos Hazardous Emergency Response Act (AHERA).

Asbestos containing materials as defined by the Occupational Safety and Health Administration (OSHA), the Environmental

Protection Agency and the State of Wyoming are material with asbestos concentration greater than 1% (>1%) by volume.

However, OSHA governs asbestos exposures to employees above the Permissible Exposure Limit regardless of asbestos containing material concentration.

No inspection can eliminate the uncertainty regarding the presence of ACM. ATS’s level of diligence and investigative procedures are intended to reduce, but not eliminate potential uncertainty regarding the presence of ACM. The determinations in this report should not be constructed as a guarantee that all ACM present in the subject property has been included in this report.

The inspection was performed in a manner consistent with the level of care and expertise exercised by members of the asbestos inspection and assessment profession. Those entities and persons involved with the inspection and generation of this report do not imply or guarantee that all potential ACM on or in the building has been identified and sampled.

Historically, asbestos has been added as a component to over 3,000 materials and products produced in the United States.

The inspection was intended to identify those accessible materials that were reasonable suspect and that were most likely to contain asbestos in quantities subject to regulation, based on existing industry and regulatory standards.

If suspect material is discovered during renovation or demolition, work needs to be stopped and suspect material needs to be tested prior to proceeding.

Total samples taken: 40

FIELD NOTES AND SAMPLE LOCATIONS:

Sample #/Description Location:

1ST FLOOR – INTERIOR:

• 042524-B34-1 Grey vinyl cove base and tan glue on drywall Room #151

• 042524-B34-2 Blue and tan rolled carpet flooring on wood Room #151

• 042524-B34-3 Drywall with orange-peel texture Room #151

• 042524-B34-4 Yellow floor sealant under carpet, on wood Hall

• 042524-B34-5 Grey carpet square and tan glue Hall

• 042524-B34-6 Grey cove base and drywall texture Room #180

• 042524-B34-7 Blue and tan rolled carpet Room #180

• 042524-B34-8 Brown cove base Room #180

• 042524-B34-9 Blue and tan carpet Room #169

• 042524-B34-10 Floor sealants under carpet Room #169

• 042524-B34-11 Grey carpet square Hall

• 042524-B34-12 Floor sealants Hall

• 042524-B34-13 Black and grey high traffic carpet South Entrance

• 042524-B34-14 Grey transition strip South Entrance

• 042524-B34-15 Black and grey high traffic carpet South Entrance

• 042524-B34-16 Brown cove base Hall

• 042524-B34-17 Drywall with orange-peel texture Hall

• 042524-B34-18 Light brown cove base Room #104

• 042524-B34-19 Pink/purple/blue rolled carpet Room #104

2ND FLOOR – INTERIOR:

• 042524-B34-20 Remnant black glue near elevator transition Hall #240

• 042524-B34-21 Drywall with orange-peel texture Hall #240

• 042524-B34-22 Caulking and remnant orange glue near wall to floor corner Hall

• 042524-B34-23 Tan carpet (remnant) Hall

• 042524-B34-24 Remnant orange/brown glue on painted CMU block wall, North Hall

• 042524-B34-25 Drywall with orange-peel texture Hall

• 042524-B34-26 Grey and black striped carpet square Hall

• 042524-B34-27 Blue and tan rolled carpet Room #292

• 042524-B34-28 Tan glue on wood floor Room #292

• 042524-B34-29 Grey cove base Room #292

• 042524-B34-30 Grey cove base Room #214

• 042524-B34-31 Drywall with orange-peel texture Room #214

• 042524-B34-32 Pink/orange vinyl transition bar Room #214

3RD FLOOR – INTERIOR:

• 042524-B34-33 CMU mortar, Northwest wall Room #304C

• 042524-B34-34 Remnant orange/brown glue on painted CMU block wall, North Room #304C

• 042524-B34-35 Sealants on CMU block wall Room #304C

• 042524-B34-36 Brown and grey striped carpet square Hallway

• 042524-B34-37 Black mastic on wood underlayment Room #312

• 042524-B34-38 Terrazzo rock flooring Room #312

• 042524-B34-39 Concrete floor fill Room #312

• 042524-B34-40 Plaster and skim-coat Room #312

FINDINGS:

None of the samples collected above were found to contain asbestos. Please refer to the attached CA Lab results.

Please feel free to contact me with any questions.

Sincerely, Nate Challenger

Asbestos Building Inspector

Attn:

Customer Project:

Reference #: Date: 04/30/24

Analysis and Method

Discussion

Qualifications

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Materials Characterization - Bulk Asbestos Analysis Laboratory Analysis Report - Polarized Light

Asbestos & Technical Services P.O. Box 2574

Cheyenne, WY 82003

David Blackwell

042524-B34, FE Warren AFB, B34

CAL24043269AS

Summary of polarized light microscopy (PLM / Stereomicroscopy bulk asbestos analysis) using the methods described in 40CFR Part 763

Appendix E to Subpart E (Interim and EPA 600 / R-93 / 116 (Improved). The sample is first viewed with the aid of a stereomicroscope. Numerous liquid slide preparations are created for analysis under the polarized microscope where identifications and quantifications are preformed. Calibrated liquid refractive oils are used as liquid mouting medium. These oils are used for identification (dispersion staining). A calibrated visual estimation is reported, should any asbestiform mineral be present. Other techniques such as acid washing are used in conjugation with refractive oils for detection of smaller quantities of asbestos. All asbestos percentages are based on calibrated visual estimation traceable to NIST standards for regulated asbestos. Traceability to measurement and calibration is achieved by using known amounts and types of asbestos from standards where analyst and laboratory accuracy are measured. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 0.50% (well above the laboratory definition of trace).

Vermiculite containing samples may contain trace amounts of actinolite/tremolite. When not detected by PLM, these samples should be analyzed using TEM methods and / or water separation techniques. Suspected actinolite/vermiculite presence will be indicated through the sample comment section of this report.

Fibrous talc containing samples may contain a regulated asbestos fiber known as anthophyllite. Under certain conditions the same fiber may actually contain both talc and anthophyllite (a phenomenon called intergrowth). Again, TEM detection methods are recommended. CA Labs PLM report comments will denote suspected amounts of asbestiform anthophyllite with talc, where further analysis is recommended.

Some samples (floor tiles, surfacings, etc.) may contain fibers too small to be detectable by PLM analysis and should be analyzed by TEM bulk protocols.

A "trace asbestos" will be reported if the analyst observes far less than 1% asbestos. CA Labs defines "trace asbestos" as a few fibers detected by the analyst in several preparations and will indicate as such under these circumstances.

Since allowable variation in quantification of samples close to 1% is high, <1% may be reported. Such results are ideal for point counting, and the technique is mandatory for friable samples (NESHAP, Nov. 1990 and clarification letter 8 May 1991) under 1% percent asbestos or "trace asbestos".

In order to make all initial PLM reports issued from CA Labs NESHAP compliant, all <1% asbestos results (except floor tiles) will be point counted at no additional charge.

CA Labs is accredited by the National Voluntary Accreditation Program (NVLAP) for selected test methods for airborne fiber analysis (TEM), and for bulk asbestos fiber analysis (PLM). CA Labs is also accredited by AIHA LAP, LLC. in the PLM asbestos field of testing for Industrial Hygiene. All analysts have completed college courses or hold a degree in a natural science (geology, biology, or environmental science). Recognition by a state professional board in one these disciplines is preferred, but not required. Extensive in-house training programs are used to augment the educational background of the analyst. The Laboratory Director and Quality Manager have received supplemental McCrone Research training for asbestos identification. Analysis performed at Crisp Analytical Labs, LLC 1929 Old Denton Road Carrollton, TX 75006

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Labs

A

C

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 1 of 10

Customer Project: 042524-B34, FE Warren AFB, B34 CA Labs Project #: CAL24043269AS

No Asbestos Detected.

Glossary of abbreviations (non-asbestos fibers and non-fibrous minerals):

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Overview of Project Sample Material Containing Asbestos

Laboratory

Sample ID

Sample # Layer # Analysts Physical Description of

Subsample

Asbestos type / calibrated visual estimate percent

List of Affected

Building Material

Types

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929 ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

This report relates to the items tested as received. This report is not to be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, AIHA LAP, LLC, or any other agency of the federal government. This report may not be reproduced except in full without written permission from CA Labs. These results are submitted pursuant to CA Labs' current terms and sale, condition of sale, including the company's standard warranty and limitations of liability provisions and no responsibility or liability is assumed for the manner in which the results are used or interpreted.

Unless notified in writing to return the samples covered by this report, CA Labs will store the samples for a period of ninety (90) days before discarding. A shipping or handling fee may be assessed for the return of any samples.

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 2 of 10

Customer Info: Attn:

Date:

Phone #

Fax #

Justin Cox Senior Analyst

Analyst Julio Robles

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services CAL24043269AS

P.O. Box 2574

Cheyenne, WY 82003

Customer Project:

042524-B34, FE Warren AFB, B34 Turnaround Time: 4/30/2024

2 Days Samples Rec'd: 4/26/24 10:30AM

307-214-0904 Date Of Sampling: 4/25/2024

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

36964

042524-B34-

1 1-1 Cove Base/ gray baseboard y None Detected 100% gy,ma

36964 1-2 tan mastic y None Detected 100% gy,bi

36965

042524-B34-

2 2-1 Carpet/ blue carpeting y None Detected 100% sy

36965 2-2 tan mastic y None Detected 100% gy,bi

36966

042524-B34-

3 3-1

100% gy,bi,ot

Drywall/ tan drywall with brown paper n None Detected 15% ce

5-1

85% qu,gy

36967

042524-B34-

4 4-1 Floor Sealant/ tan mastic with debris n None Detected

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

Carpet/ black carpeting y None Detected 100% sy36968

042524-B34-

Approved Signatories:

Technical Manager ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

10. TEM analysis suggested

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 3 of 10

Phone #

Fax #

Justin Cox Senior Analyst

Analyst Julio Robles

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services CAL24043269AS

P.O. Box 2574

Cheyenne, WY 82003

Customer Project:

042524-B34, FE Warren AFB, B34 Turnaround Time: 4/30/2024

2 Days Samples Rec'd: 4/26/24 10:30AM

307-214-0904 Date Of Sampling: 4/25/2024

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

36969

042524-B34-

6 6-1 Cove Base/ gray baseboard y None Detected 100% gy,ma

36969 6-2 tan mastic y None Detected 100% gy,bi

36970

042524-B34-

7 7-1 Carpet/ black carpeting y None Detected 100% sy

36971

042524-B34-

8 8-1 Cove Base/ brown baseboard y None Detected 100% gy,ma

36972

042524-B34-

9 9-1

100% gy,bi

Carpet/ blue carpeting y None Detected 100% sy

10-2

36973

042524-B34-

10 10-1 Floor Sealant/ tan mastic y None Detected

100% qu,ca

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

gray grouting y None Detected36973

Approved Signatories:

Technical Manager ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 4 of 10

Phone #

Fax #

Justin Cox Senior Analyst

Analyst Julio Robles

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services CAL24043269AS

P.O. Box 2574

Cheyenne, WY 82003

Customer Project:

042524-B34, FE Warren AFB, B34 Turnaround Time: 4/30/2024

2 Days Samples Rec'd: 4/26/24 10:30AM

307-214-0904 Date Of Sampling: 4/25/2024

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

36974

042524-B34-

11 11-1 Carpet/ black carpeting y None Detected 100% sy

36975

042524-B34-

12 12-1 Floor Sealant/ tan mastic y None Detected 100% gy,bi

36975 12-2 gray grouting y None Detected 100% qu,ca

36976

042524-B34-

13 13-1 Carpet/ black carpeting y None Detected 100% sy

36977

042524-B34-

14 14-1

100% sy

Transition Strip/ brown baseboard y None Detected

16-1

100% gy,ma

36978

042524-B34-

15 15-1 Carpet/ black carpeting y None Detected

100% gy,ma

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

Cove Base/ brown baseboard y None Detected36979

042524-B34-

Approved Signatories:

Technical Manager ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 5 of 10

Phone #

Fax #

Justin Cox Senior Analyst

Analyst Julio Robles

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services CAL24043269AS

P.O. Box 2574

Cheyenne, WY 82003

Customer Project:

042524-B34, FE Warren AFB, B34 Turnaround Time: 4/30/2024

2 Days Samples Rec'd: 4/26/24 10:30AM

307-214-0904 Date Of Sampling: 4/25/2024

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

36980

042524-B34-

17 17-1 Drywall/ white surfaced white compound n None Detected

100% mi,qu,bi,ca

36980 17-2 tan drywall with brown paper n None Detected 15% ce 85% qu,gy

36981

042524-B34-

18 18-1 Carpet/ brown baseboard y None Detected 100% gy,ma

36982

042524-B34-

19 19-1 Cove Base/ gray carpeting y None Detected 100% sy

36983

042524-B34-

20 20-1

100% mi,qu,bi,ca

Transition Strip/ tan mastic with debris n None Detected

22-1

100% gy,bi,ot

36984

042524-B34-

21 21-1 Drywall/ white surfaced white compound n None Detected

100% qu,bi,ca

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

Caulking/ white surfaced red caulking n None Detected36985

042524-B34-

Approved Signatories:

Technical Manager ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 6 of 10

Phone #

Fax #

Justin Cox Senior Analyst

Analyst Julio Robles

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services CAL24043269AS

P.O. Box 2574

Cheyenne, WY 82003

Customer Project:

042524-B34, FE Warren AFB, B34 Turnaround Time: 4/30/2024

2 Days Samples Rec'd: 4/26/24 10:30AM

307-214-0904 Date Of Sampling: 4/25/2024

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

36986

042524-B34-

23 23-1 Carpet/ gray carpeting y None Detected 100% sy

36987

042524-B34-

24 24-1 Drywall/ white surfaced white compound n None Detected

100% mi,qu,bi,ca

36988

042524-B34-

25 25-1 Cove Base/ black baseboard y None Detected 100% gy,ma

36989

042524-B34-

26 26-1 Carpet/ gray carpeting y None Detected 100% sy

36990

042524-B34-

27 27-1

100% gy,bi

Carpet/ blue carpeting y None Detected 100% sy

29-1

36991

042524-B34-

28 28-1 Glue/ tan mastic y None Detected

100% gy,ma

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

Cove Base/ gray baseboard y None Detected36992

042524-B34-

Approved Signatories:

Technical Manager ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 7 of 10

Phone #

Fax #

Justin Cox Senior Analyst

Analyst Julio Robles

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services CAL24043269AS

P.O. Box 2574

Cheyenne, WY 82003

Customer Project:

042524-B34, FE Warren AFB, B34 Turnaround Time: 4/30/2024

2 Days Samples Rec'd: 4/26/24 10:30AM

307-214-0904 Date Of Sampling: 4/25/2024

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

36993

042524-B34-

30 30-1 Cove Base/ gray baseboard y None Detected 100% gy,ma

36993 30-2 tan mastic y None Detected 100% gy,bi

36994

042524-B34-

31 31-1 Drywall/ white drywall with brown paper n None Detected 15% ce 85% qu,gy

36995

042524-B34-

32 32-1 Transition Bar/ brown baseboard y None Detected 100% gy,ma

36995 32-2

100% sy tan mastic y None Detected

34-1

100% gy,bi

36996

042524-B34-

33 33-1 Carpet/ brown carpeting y None Detected

100% gy,ma

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

Cove Base/ brown baseboard y None Detected36997

042524-B34-

Approved Signatories:

Technical Manager ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 8 of 10

Phone #

Fax #

Justin Cox Senior Analyst

Analyst Julio Robles

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services CAL24043269AS

P.O. Box 2574

Cheyenne, WY 82003

Customer Project:

042524-B34, FE Warren AFB, B34 Turnaround Time: 4/30/2024

2 Days Samples Rec'd: 4/26/24 10:30AM

307-214-0904 Date Of Sampling: 4/25/2024

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

36997 34-2 tan mastic y None Detected 100% gy,bi

36998

042524-B34-

35 35-1 Drywall/ tan surfaced white compound n None Detected

100% mi,qu,bi,ca

36998 35-2 tan drywall with brown paper n None Detected 10% ce 90% qu,gy

36999

042524-B34-

36 36-1 Carpet/ gray carpeting y None Detected 100% sy

37000

042524-B34-

37 37-1

100% qu,ma,ot

Mastic/ black felt y None Detected 35% ce

39-1

65% qu,bi

37001

042524-B34-

38 38-1 Terrazzo/ red terrazzo tile y None Detected

100% qu,ca

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

Floor Sealant/ gray concrete y None Detected37002

042524-B34-

Approved Signatories:

Technical Manager ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 9 of 10

Phone #

Fax #

Justin Cox Senior Analyst

Analyst Julio Robles

CA Labs Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road Carrollton, TX 75006 Phone 972-242-2754 Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32 Baton Rouge, LA 70809 Phone 225-751-5632 Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services CAL24043269AS

P.O. Box 2574

Cheyenne, WY 82003

Customer Project:

042524-B34, FE Warren AFB, B34 Turnaround Time: 4/30/2024

2 Days Samples Rec'd: 4/26/24 10:30AM

307-214-0904 Date Of Sampling: 4/25/2024

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

37003

042524-B34-

40 40-1 Plaster/ green surfaced white finishing compound n None Detected

100% qu,bi,ca

37003 40-2 gray plaster y None Detected 100% qu,bi,ca

Dallas NVLAP Lab Code 200349-0 TEM/PLM TDSHS 30-0235 AIHA LAP, LLC Laboratory #102929

Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:

Technical Manager

Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 6 10/30/2023) Page 10 of 10

Cheyenne, WY 82003

Asbestos & Lead Inspection Report

February 10, 2023

Chris Carter

Project: FE Warren AFB, Building 34 (SFG 2nd Floor Carpet Replacement)

Cheyenne, WY 82001

Dear Mr. Carter, On February 7, 2023, ATS performed an asbestos inspection of the above-mentioned project. The purpose of the survey is to identify asbestos containing material (ACM) using nondestructive sampling protocols.

Inspection, sampling and analytical procedures were performed in general accordance with the Environmental Protection

Agency’s (EPA) interpretations, and guidelines of the Asbestos Hazardous Emergency Response Act (AHERA).

Asbestos containing materials as defined by the Occupational Safety and Health Administration (OSHA), the Environmental

Protection Agency and the State of Wyoming are material with asbestos concentration greater than 1% (>1%) by volume.

However, OSHA governs asbestos exposures to employees above the Permissible Exposure Limit regardless of asbestos containing material concentration.

No inspection can eliminate the uncertainty regarding the presence of ACM. ATS’s level of diligence and investigative procedures are intended to reduce, but not eliminate potential uncertainty regarding the presence of ACM. The determinations in this report should not be constructed as a guarantee that all ACM present in the subject property has been included in this report.

The inspection was performed in a manner consistent with the level of care and expertise exercised by members of the asbestos inspection and assessment profession. Those entities and persons involved with the inspection and generation of this report do not imply or guarantee that all potential ACM on or in the building has been identified and sampled.

Historically, asbestos has been added as a component to over 3,000 materials and products produced in the United States.

The inspection was intended to identify those accessible materials that were reasonable suspect and that were most likely to contain asbestos in quantities subject to regulation, based on existing industry and regulatory standards.

If suspect material is discovered during renovation or demolition, work needs to be stopped and suspect material needs to

Total samples taken: 9

2ND FLOOR – INTERIOR:

• 020723-B34-1 Grey vinyl cove base and tan glue on drywall Room #292

• 020723-B34-2 Grey brick mortar and red brick wall Room #292

• 020723-B34-3 CMU mortar, Northwest wall Room #292

• 020723-B34-4 Remnant orange/brown glue on painted CMU block wall, North Room #292

• 020723-B34-5 Sealants on CMU block wall Room #290D

• 020723-B34-6 Pale yellow and painted paper wrapped pipe insulation Room #290D

• 020723-B34-7 Off-white fitting material and painted cloth wrap Room #290D

• 020723-B34-8 Brown insulation and tar paper (below roof deck) Room #290D

• 020723-B34-9 Black cove base and brown glue on CMU wall Hallway #290

FINDINGS:

None of the samples collected above were found to contain asbestos. Please refer to the attached CA Lab results.

LEAD INSPECTION NOTES:

On February 7, 2023, ATS performed non-invasive/non-destructive inspection services for FE Warren AFB, Building 34, Cheyenne Wyoming in the proposed work area. The purpose of this inspection was to identify where lead-based (LBP) may reside for planned building renovations and determine if corrective measures should be taken to minimize possible exposure. ATS tested the following:

Total samples taken: 4 (homogeneous throughout renovation areas)

Lead Analysis Location: Color Change:

• L-01, Tan paint on grey paint on drywall Interior- Room #290 - Side D NO

Testing Method: 3M Lead Test (swab) Kit.

RESULTS: After a 5-minute wait time, the sample collected above did not show signs of changing color and ATS assumes that the associated paint layers for Hallway #290 and the adjacent offices (5 areas) does not contain lead paint.

PHOTOS:

Background for Lead Test Kits:

On April 22, 2008, EPA published the Lead Renovation, Repair and Painting (RRP) rule, which, among other things, established performance recognition criteria for lead test kits for use as an option to determine if regulated lead-based paint is not present in target housing and child-occupied facilities. Currently, the EPA is reviewing the application and expansion of the RRP rule to include public and commercial buildings. According to the EPA, the use of an EPA-recognized lead test kit, when used by a trained professional, can reliably determine that regulated lead-based paint is not present by virtue of a negative result. The EPA recognizes that when used by a Certified Renovator, the 3M™ Lead Check™ lead test kit can reliably determine that regulated lead-based paint is not present on wood, ferrous metal (alloys that contain iron), or drywall and plaster surfaces. The results of swab testing are not quantitative. A positive result may indicate the presence of lead-based paint and should be dealt with by an EPA- RRP contractor or certified Lead Abatement firm.

IN

SP

EC

TIO

N

F.E. W A

R R

EN

A

.F.B ., B

, C H

EY

EN

N E W

Y:

B U

LK

SA

M P

LES FR

O

M

FEB

R U

A R

Y

, 2

N

D

FLO

O R

SFG

(n o t to scale

B u lk S a m p le

L o c a tio n s

N o n -d e te c t

T ra c e (0

-1

A

C M

(a b o v e

.0

T ra c e (0

-1

A

SB

ESTO

S &

TEC

H

N

IC

A L

SER

V

IC

ES, IN

C

N O R T H

2 3

5 6

A

D

B

C

S w ip e

S a m p le L o c a tio n s

N o

C o lo r C h a n g e C o lo r C h a n g e

S ta irs

L

Attn:

Reference #: Date: 02/09/23

Analysis and Method

Discussion

Qualifications

CA Labs

Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road

Carrollton, TX 75006

Phone 972-242-2754

Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

Materials Characterization - Bulk Asbestos Analysis Laboratory Analysis Report - Polarized Light

Asbestos & Technical Services David Blackwell

P.O. Box 2574

Cheyenne, WY 82003 020723-B34, FE Warren AFB, B34

CAL23021129AS

Summary of polarized light microscopy (PLM / Stereomicroscopy bulk asbestos analysis) using the methods described in 40CFR Part 763

Appendix E to Subpart E (Interim and EPA 600 / R-93 / 116 (Improved). The sample is first viewed with the aid of a stereomicroscope. Numerous liquid slide preparations are created for analysis under the polarized microscope where identifications and quantifications are preformed. Calibrated liquid refractive oils are used as liquid mouting medium. These oils are used for identification (dispersion staining). A calibrated visual estimation is reported, should any asbestiform mineral be present. Other techniques such as acid washing are used in conjugation with refractive oils for detection of smaller quantities of asbestos. All asbestos percentages are based on calibrated visual estimation traceable to NIST standards for regulated asbestos. Traceability to measurement and calibration is achieved by using known amounts and types of asbestos from standards where analyst and laboratory accuracy are measured. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 0.50% (well above the laboratory definition of trace).

Vermiculite containing samples may contain trace amounts of actinolite/tremolite. When not detected by PLM, these samples should be analyzed using TEM methods and / or water separation techniques. Suspected actinolite/vermiculite presence will be indicated through the sample comment section of this report.

Fibrous talc containing samples may contain a regulated asbestos fiber known as anthophyllite. Under certain conditions the same fiber may actually contain both talc and anthophyllite (a phenomenon called intergrowth). Again, TEM detection methods are recommended. CA Labs PLM report comments will denote suspected amounts of asbestiform anthophyllite with talc, where further analysis is recommended.

Some samples (floor tiles, surfacings, etc.) may contain fibers too small to be detectable by PLM analysis and should be analyzed by TEM bulk protocols.

A "trace asbestos" will be reported if the analyst observes far less than 1% asbestos. CA Labs defines "trace asbestos" as a few fibers detected by the analyst in several preparations and will indicate as such under these circumstances.

Since allowable variation in quantification of samples close to 1% is high, <1% may be reported. Such results are ideal for point counting, and the technique is mandatory for friable samples (NESHAP, Nov. 1990 and clarification letter 8 May 1991) under 1% percent asbestos or "trace asbestos".

In order to make all initial PLM reports issued from CA Labs NESHAP compliant, all <1% asbestos results (except floor tiles) will be point counted at no additional charge.

CA Labs is accredited by the National Voluntary Accreditation Program (NVLAP) for selected test methods for airborne fiber analysis (TEM), and for bulk asbestos fiber analysis (PLM). CA Labs is also accredited by AIHA LAP, LLC. in the PLM asbestos field of testing for Industrial Hygiene. All analysts have completed college courses or hold a degree in a natural science (geology, biology, or environmental science). Recognition by a state professional board in one these disciplines is preferred, but not required. Extensive in-house training programs are used to augment the educational background of the analyst. The Laboratory Director and Quality Manager have received supplemental McCrone Research training for asbestos identification. Analysis performed at Crisp Analytical Labs, LLC 1929 Old Denton Road Carrollton, TX 75006

Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235

AIHA LAP, LLC Laboratory #102929

Labs

A

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 1 of 5

Customer Project: 020723-B34, FE Warren AFB, B34 CA Labs Project #: CAL23021129AS

Glossary of abbreviations (non-asbestos fibers and non-fibrous minerals):

CA Labs

Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road

Carrollton, TX 75006

Phone 972-242-2754

Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

Overview of Project Sample Material Containing Asbestos

Laboratory

Sample ID

Sample # Layer # Analysts Physical Description of

Subsample

Asbestos type / calibrated visual estimate percent

List of Affected

Building Material

Types

Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235

AIHA LAP, LLC Laboratory #102929 ca - carbonate gypsum - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastinite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay)

This report relates to the items tested. This report is not to be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST, AIHA LAP, LLC, or any other agency of the federal government. This report may not be reproduced except in full without written permission from CA Labs. These results are submitted pursuant to CA Labs' current terms and sale, condition of sale, including the company's standard warranty and limitations of liability provisions and no responsibility or liability is assumed for the manner in which the results are used or interpreted. Unless notified in writing to return the samples covered by this report, CA Labs will store the samples for a period of ninety (90) days before discarding. A shipping or handling fee may be assessed for the return of any samples.

Labs

A

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 2 of 5

Customer Info: Attn: Customer Project:

Phone #

Fax #

John Monaco Senior Analyst

Analyst Julio Robles

CA Labs

Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road

Carrollton, TX 75006

Phone 972-242-2754

Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services 020723-B34, FE Warren AFB, B34

CAL23021129AS

P.O. Box 2574

Cheyenne, WY 82003 Turnaround Time: 2/9/2023

24 Hours Samples Rec'd: 2/9/23 10:30AM

307-214-0904 Date Of Sampling: 2/7/2023

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

10750 B34-1 B34-1-

1 Cove Base/ gray baseboard y None Detected 100% gy,ma

10750 B34-1-

2 tan mastic y None Detected 100% gy,bi

10751 B34-2 B34-2-

Drywall/ tan surfaced white compound n None Detected 100% qu,bi,ca

10751 B34-2-

2 pink drywall with brown paper n None Detected 20% ce 80% qu,gy

10752 B34-3 B34-3-

Carpet/ black and blue carpeting y None Detected 100% sy

10752 B34-3-

2 tan mastic y None Detected 100% gy,bi

10753 B34-4 B34-4-

Adhesive/ tan mastic with brown wooden fragments n None Detected 30% ce 70% gy,bi

Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235

AIHA LAP, LLC Laboratory #102929 Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

ca - carbonate gy - gypsum bi - binder or - organic ma - matrix mi - mica ve - vermiculite ot - other pe - perlite qu - quartz fg - fiberglass mw - mineral wool wo - wollastonite ta - talc sy - synthetic ce - cellulose br - brucite ka - kaolin (clay) pa - palygorskite (clay) Approved Signatories:

Julio Robles Technical Manager

Analyst Tanner Rasmussen

1. Fire Damage significant fiber damage - reported percentages reflect unaltered fibers

2. Fire Damage no significant fiber damages effecting fibrous percentages

3. Actinolite in association with Vermiculite

4. Layer not analyzed - attached to previous positive layer and contamination is suspected

5. Not enough sample to analyze

6. Anthophyllite in association with Fibrous Talc

7. Contamination suspected from other building materials

8. Favorable scenario for water separation on vermiculite for possible analysis by another method

9. < 1% Result point counted positive

10. TEM analysis suggested

Labs

A

/data/wordandspreadsheets/templates/asbestos/PLMReport.xls (Revision 4 2/25/2020) Page 3 of 5

Phone #

Fax #

John Monaco Senior Analyst

Analyst Julio Robles

CA Labs

Dedicated to QualityDedicated to QualityDedicated to QualityDedicated to Quality

Crisp Analytical, L.L.C.

1929 Old Denton Road

Carrollton, TX 75006

Phone 972-242-2754

Fax 972-242-2798

CA Labs, L.L.C.

12232 Industriplex, Suite 32

Baton Rouge, LA 70809

Phone 225-751-5632

Fax 225-751-5634

Polarized Light Asbestiform Materials Characterization

David Blackwell CA Labs Project #:

Asbestos & Technical Services 020723-B34, FE Warren AFB, B34

CAL23021129AS

P.O. Box 2574

Cheyenne, WY 82003 Turnaround Time: 2/9/2023

24 Hours Samples Rec'd: 2/9/23 10:30AM

307-214-0904 Date Of Sampling: 2/7/2023

Purchase Order #:

Laboratory

Sample ID

Sample # Com ment

Layer

Analysts Physical Description of

Subsample

Homo-geneo us

(Y/N)

Asbestos type / calibrated visual estimate percent

Non-asbestos fiber type / percent

Non-fibrous type / percent

10754 B34-5 B34-5-

Adhesive/ tan mastic with brown wooden fragments n None Detected 30% ce 70% gy,bi

10755 B34-6 B34-6-

1 Carpet/ blue carpeting y None Detected 100% sy

10755 B34-6-

2 tan mastic y None Detected 100% gy,bi

10756 B34-7 B34-7-

1 Cove Base/ gray baseboard y None Detected 100% gy,ma

10756 B34-7-

2 tan mastic y None Detected 100% gy,bi

10757 B34-8 B34-8-

Drywall/ white surfaced white compound n None Detected 100% qu,bi,ca

10757 B34-8-

2 white drywall with brown paper n None Detected 20% ce 80% qu,gy

Dallas NVLAP Lab Code 200349-0 TEM/PLM TCEQ# T104704513-15-3 TDH 30-0235

AIHA LAP, LLC Laboratory #102929 Analysis Method: Interim (40CFR Part 763 Appendix E to Subpart E) / Improved (EPA-600 / R-93/116). All samples received in good condition unless noted.

Preparation Method: HCL acid washing for carbonate based samples, chemical reduction for organically bound components, oil immersion for identification of asbestos types by dispersion attaining / becke line method.

ca -…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .