This is a Fixture Conversion Schedule for Clarkston Community Schools' Early Childhood Center, detailing a comprehensive LED lighting retrofit project. The document specifies the conversion of existing fluorescent fixtures to energy-efficient LED alternatives across the entire facility, including classrooms, administrative offices, hallways, bathrooms, and mechanical spaces. The project encompasses 503 existing fixtures requiring conversion to 503 replacement fixtures, resulting in a total of 958 individual lamps, fixtures, or devices. The vast majority of conversions involve replacing 4-foot 3-lamp or 2-lamp 32W T8 fluorescent fixtures with 4-foot 15W 4000K LED linear tubes through a retrofit process that removes existing fluorescent tubes and installs 2 LED linear tubes per fixture. Additional conversions include replacing 1-lamp 32W PL downlights in 8-inch recessed housings with 10W 4000K LED downlights, and 2-lamp 32W PL pendant fixtures with 7W 4000K LED PL lamps. The retrofit approach is standardized across nearly all applications, maintaining the existing fixture housings while upgrading the light sources.

The document provides detailed specifications for each room and area within the Early Childhood Center, organized by functional areas such as classrooms (201-216), administrative sections, storage and mechanical spaces, and hallway and bathroom zones. Classroom fixtures account for the majority of conversions, with rooms like 203, 201, 204, 202, 207-216, 209, and 210 each containing 15 main fixtures requiring conversion, plus associated storage and bathroom fixtures. The conversion plan maintains consistency in methodology across the facility, with retrofit fixtures specified to remove three existing fluorescent tubes and replace them with two LED linear tubes, optimizing energy efficiency while maintaining appropriate lighting levels. No pricing information, contract terms, award dates, or bidding procedures are specified in this schedule, as it functions as a technical specification document defining the scope and nature of the LED conversion work.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment #23

Type of Area Room Name Type of Fixture Replacement Product

# of Existing

Fixtures or

Devices

# of

Replacement

Fixtures or

Devices Fixture Conversion Plan

# of

Replacement

Lamps / Fixture

Total # of

Lamps, Fixtures, or Devices

Classrooms LGR Motor Skills 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms Occupational & PT 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 8 8 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 16

Classrooms 206 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 206 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 206 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms RCC 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Storage and Mechanical Mechanical Room 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 18 18 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 36

Classrooms 205 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 205 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 205 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Hallways and Bathrooms Staff Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Hallways and Bathrooms Staff Bathroom 1 Lamp 32W PL in 8" RC 10W 4000K LED Down Light 1 1 Replace existing fixture with a new LED down light. 1 1

Hallways and Bathrooms Bathrooms - Boys 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Hallways and Bathrooms Bathrooms - Girls 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Hallways and Bathrooms Staff Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Hallways and Bathrooms Staff Bathroom 1 Lamp 32W PL in 8" RC 10W 4000K LED Down Light 1 1 Replace existing fixture with a new LED down light. 1 1

Fixture Conversion Schedule

Clarkston Community Schools

Early Childhood Center

# of Existing

Fixtures or

Devices

# of

Replacement

Fixtures or

Devices Fixture Conversion Plan

# of

Replacement

Lamps / Fixture

Total # of

Lamps, Fixtures, or Devices

Fixture Conversion Schedule

Clarkston Community Schools

Early Childhood Center

Classrooms Spice 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Classrooms 203 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 16 16 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 32

Classrooms 203 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 203 Bathrooms 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Classrooms 201 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 16 16 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 32

Classrooms 201 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 201 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 204 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 204 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Classrooms 204 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 202 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 202 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 202 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms Speech Office 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Storage and Mechanical Custodial Closet 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Hallways and Bathrooms Lobby Area 2 Lamp 32W PL in 8" RC 10W 4000K LED Down Light 9 9 Replace existing fixture with a new LED down light. 1 9

# of Existing

Fixtures or

Devices

# of

Replacement

Fixtures or

Devices Fixture Conversion Plan

# of

Replacement

Lamps / Fixture

Total # of

Lamps, Fixtures, or Devices

Fixture Conversion Schedule

Clarkston Community Schools

Early Childhood Center

Administration Records 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Hallways and Bathrooms Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Administration Office 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Administration Conference Room 200 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Administration Office 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Administration Group 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 3 3 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 6

Storage and Mechanical Air Handling 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 5 5 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 10

Hallways and Bathrooms Lobby Area 2 Lamp 32W PL in Pendent 7W 4000K LED PL Lamp 4 4 Replace existing fixture with a new LED down light. 1 4

Hallways and Bathrooms Lobby Area 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Storage and Mechanical Custodial Closet 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Hallways and Bathrooms Bathrooms - Boys 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Hallways and Bathrooms Bathrooms - Girls 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Hallways and Bathrooms Bathrooms - Boys 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Hallways and Bathrooms Bathrooms - Girls 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Classrooms 211 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 211 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

# of Existing

Fixtures or

Devices

# of

Replacement

Fixtures or

Devices Fixture Conversion Plan

# of

Replacement

Lamps / Fixture

Total # of

Lamps, Fixtures, or Devices

Fixture Conversion Schedule

Clarkston Community Schools

Early Childhood Center

Classrooms 211 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 212 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 212 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 212 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 213 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 213 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 213 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 214 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 214 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 214 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 215 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 215 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 215 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 216 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 216 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 216 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

# of Existing

Fixtures or

Devices

# of

Replacement

Fixtures or

Devices Fixture Conversion Plan

# of

Replacement

Lamps / Fixture

Total # of

Lamps, Fixtures, or Devices

Fixture Conversion Schedule

Clarkston Community Schools

Early Childhood Center

Storage and Mechanical Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 3 3 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 6

Storage and Mechanical Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 2 2 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 4

Storage and Mechanical Electrical Closet 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 4 4 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 8

Classrooms 209 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 209 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 209 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 210 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 210 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 210 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 208 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 208 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 208 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 207 4' 3 Lamp 32W T8 4' 15W 4000K LED Linear Tube 15 15 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 30

Classrooms 207 Storage 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Classrooms 207 Bathroom 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 1 1 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 2

Hallways and Bathrooms Hallways 4' 2 Lamp 32W T8 4' 15W 4000K LED Linear Tube 46 46 Retrofit fixture. Remove the existing 3 fluorescent tubes and replace them with 2 LED linear tubes.

2 92

# of Existing

Fixtures or

Devices

# of

Replacement

Fixtures or

Devices Fixture Conversion Plan

# of

Replacement

Lamps / Fixture

Total # of

Lamps, Fixtures, or Devices

Fixture Conversion Schedule

Clarkston Community Schools

Early Childhood Center

Hallways and Bathrooms Hallways 2' 2 Lamp 32W T8 UB 2' 15W 4000K LED Linear Tube 23 23 Retrofit fixture. Replace existing fluorescent tubes with LED linear tubes on a one for one basis.

2 46

Hallways and Bathrooms Hallways 1 Lamp 32W PL in 8" RC 10W 4000K LED Down Light 28 28 Replace existing fixture with a new LED down light. 1 28

Hallways and Bathrooms Hallways 2 Lamp 32W PL in Pendent 7W 4000K LED PL Lamp 5 5 Replace existing fixture with a new LED down light. 1 5

503 503 958