Attachment 2 -Temperature Dewpoint Sensor Accuracy Specification.pdf
PDF 106 KB Posted
- Solicitation number
- 142084-25-0100
About this file
Attachment 2 is a technical specification document detailing temperature and dewpoint sensor accuracy requirements for an Automatic Radiosonde Launching/Observing System (AROS). The accuracy specifications are defined across multiple temperature ranges, with precise measurement tolerances:
For ambient temperature, the sensor must maintain ±1 degree accuracy between -58°F to +122°F, and ±2 degrees through the remainder of its operational range. Dewpoint temperature accuracy is specified using Root Mean Square Error (RMSE) with varying precision: ±2°F RMSE from +30°F to +86°F, ±3°F RMSE from -10°F to +30°F, and ±4°F RMSE from -30°F to -10°F. These detailed specifications indicate the required precision for temperature and dewpoint measurements across different environmental conditions, which is critical for meteorological and atmospheric research equipment.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 2 - Temperature / Dewpoint Sensor Accuracy Specification
Temperature Accuracy
Ambient temperature ±1 degree, -58°F to +122°F
±2 degrees through remainder of operational range
Dewpoint temperature
±2°F Root Mean Square Error (RMSE) +30°F to +86°F
±3°F RMSE, -10°F to +30°F
±4°F RMSE, -30°F to -10°F