Attachment 1 - Operating and Non-Operating Conditions.pdf
PDF 114 KB Posted
- Solicitation number
- 142084-25-0100
About this file
Attachment 1 is a detailed specifications table outlining operating and non-operating environmental conditions for an Automatic Radiosonde Launching/Observing System (AROS). The document specifies technical parameters across multiple environmental factors, including air pressure (1070 hPa to 700 hPa for operating conditions), air temperature (-55°C to 50°C), relative humidity (0% to 100%), surface wind speed (≤50 knots), and precipitation limits (< 50 mm per hour). The table also indicates resistance requirements for various conditions such as ultraviolet/infrared radiation, corrosion in coastal locations, lightning, and salt/marine environments. The withstanding conditions column provides slightly expanded parameters, such as air temperature ranging to 60°C and surface wind speeds up to 112 knots, suggesting the system must endure more extreme environmental conditions beyond standard operating parameters.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 - Operating and Non-Operating Conditions
Condition Operating Conditions Withstanding
Conditions
Air Pressure 1070 hPa to 700 hPa 1070 hPa to 532 hPa
Air Temperature -55°C to 50°C -55°C to 60°C
Air RH 0% to 100% 0% to 100%
Surface wind speed ≤ 50 knots ≤ 112 knots
Liquid or frozen precipitation < 50 mm per hour < 50 mm per hour
Weight of accumulated frozen precipitation on launch door < 150 kg ≥ 150 kg
Ultraviolet, Visible and Infrared solar radiation Resistant Resistant
Corrosion conditions in coastal locations Resistant Resistant
Lightning resistant with structure and equipment connected to grounding Resistant Resistant
Salt & Marine Environment Resistant Resistant
File details come from the government source that posted it. Updated .