Attachment 2 Statement of Work (SOW).pdf
PDF 284 KB Posted
- Attached to
- 50T Crane Main Lift Cylinder Repair
- Solicitation number
- FA441825Q0006
About this file
This Statement of Work (SOW) dated 13 February 2025 details repair requirements for a Grove Rough Terrain Crane, Model RT600E (2009), Serial no. 230141, located at Joint Base Charleston Naval Weapons Station. The crane has a hydraulic fluid leak from the main boom lift cylinder's wiper seal, dripping approximately once per minute.
The contractor must transport the crane to their facility, disassemble the main boom lift cylinder, replace all seals, resurface the cylinder rod with new chrome-coating, and reinstall the refurbished cylinder. The work includes OSHA-compliant weight testing and certification, with documentation required upon delivery. The contractor is responsible for all labor, tools, parts, materials, and transportation. A one-year warranty on parts and labor is required upon completion. Any repairs identified outside this scope require prior authorization from the Contracting Officer. The work must comply with all federal, state, and local regulations, including environmental codes.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work 13 February 2025
Description of Discrepancy:
The Grove Rough Terrain Crane, Model RT600E (Year 2009), Serial no. 230141, has a hydraulic fluid leak from the main boom lift cylinder. A visual inspection indicates the leak originates from the wiper seal, with a rate of approximately one drip per minute.
Required Maintenance:
The contractor shall transport the crane to a repair facility, disassemble the main boom lift cylinder, replace all seals, resurface the cylinder rod with a new chrome-coating, and reinstall the refurbished cylinder. Upon reinstallation, the cylinder must be free of leaks and defects. The crane will undergo weight testing and certification in compliance with OSHA requirements, with certification paperwork provided upon delivery. The Contractor shall provide all labor, tools, parts, materials, and transportation to and from Joint Base Charleston Naval Weapons Station. All work must comply with applicable federal, state, and local regulations, including environmental codes. Work shall be completed to industry standards.
Scope of Work:
1. Transport the crane to the repair facility.
2. Disassemble the main boom lift cylinder, replace all seals, resurface the cylinder rod with a chrome coating, and reinstall the refurbished cylinder, ensuring it is free of leaks and defects.
3. Perform weight testing and certification in accordance with OSHA requirements, providing all certification documentation.
4. Transport the crane back to Joint Base Charleston upon certification.
5. Provide a 1 (one) year warranty on parts and labor upon completion.
If needed repairs are identified outside of this scope of work, the Contractor shall contact the Contract Specialist and the Contracting Officer immediately and shall not proceed with any additional repairs until prior authorization from the Contracting Officer is received.
Performance outside the scope of the contract will be considered voluntary and will not result in additional compensation from the government.
File details come from the government source that posted it. Updated .