Attachment 2 - Statement of Work_Bldg 266 Rooms s200 and s226 furniture_31 July 2025.pdf
PDF 3 MB Posted
- Solicitation number
- FA860125Q0135
About this file
The document is a Statement of Work (SOW) for a furniture package renovation project at Wright Patterson Air Force Base, specifically for Rooms S200 and S226 in Building 266. The project involves a phased installation approach with two primary phases: Phase 1 focuses on Room S226 and must be completed within 19 weeks of contract award, while Phase 2 involves Room S200 and must be completed within 13 weeks after Phase 1's completion. The scope includes comprehensive furniture removal, electrical disconnection, flooring replacement, and new furniture installation, with specific requirements for workstations, seating, tables, privacy screens, storage solutions, and other office furnishings.
The project requires detailed design services, with contractors expected to provide comprehensive layout drawings, 3D renderings, and precise specifications for each furniture type. Key requirements include manufacturer-certified installation, recycling of existing materials, adherence to specific design standards, and coordination with government electrical and communication work. The solicitation is a Request for Quote (RFQ) using simplified acquisition procedures, with an optional site visit scheduled for 15 August 2025 and quote submissions due by 25 August 2025. The anticipated contract is firm-fixed price, with award based on technical capability and lowest total evaluated price, targeting furniture and flooring upgrades that meet specific government specifications for Wright Patterson Air Force Base.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
01-SOW Statement of Work -Furniture Package Wright Patterson AFB, OH
DAF version 12 JUNE 2025
Packaged Office Furniture
Statement of Work
31 July 2025
10266, Rooms S200 and S226, Second Floor
Area A
4225 Logistics Ave Dayton, OH 45433
Stephanie Nishanov Wright Patterson AFB
CEG-Interior Design Specialist 5151 Wright Ave, Building 11
WPAFB, OH 45433-5339
937-207-2098
DAF version 12 JUNE 2025
Revision History
Author Name Date Reason For Changes Version
1.0 Scope
This project will be proposed using product lines with Open Market/GSA/Package Office Furniture. This project will be awarded on a competitive basis using total project cost.
The Contractor shall provide all supervision, labor, materials, equipment, and Certified Electrician to hook up the Systems Furniture and White Noise/Sound Masking to Building power; this in addition, includes transportation to accomplish this project in accordance with this Statement of Work (SOW), project drawings.
The Contractor shall provide 30 days storage, and the requirements contained in the soliciting documents.
The Contractor shall provide removal of existing furniture as stated in detail in Section
7.2 Removal of Existing Furniture. Existing Floorplans Attached, B266, Rooms S200 and S226 Existing (sheets I-7 and I-8)
The Contractor shall include an itemized quote that includes labor to receive, inspect, deliver to project job site, and install product per approved final design layout.
The Contractor may include AutoCAD design hours for all phases of design (initial, revisions and final).
The Contractor may include design hours for in person meetings to review all phases of design (initial, revisions and final), finish selections, site visits (field measurement), and any other means and methods for the contractor to execute the project.
Reference section 3.2.11 for updated power harness requirements per UFC 3-520-01 (Change 2, 16 January 2025).
For this project provide power poles and base feeds for the workstations and modular walls. A certified electrician shall provide hardwire connection complete from the workstations/ modular walls to building power. Provide break box labeling for new and/or altered circuit.
Certified electrician to provide connection complete from white noise system to building power. Provide break box labeling for new and/or altered circuit. Provide all applicable installation and material to make complete connection to building. Responsible for supplying any conduit, which may be required to complete system installation in accordance with specifications and local building codes. Install cables in raceways and cable trays
White Noise:
o Final Acceptance Testing: Provide a minimum of 10 days' notice of acceptance test performance schedule. Schedule tests after pretesting has been successfully completed.
o Perform sound-masking evaluation tests in accordance with [ASTM E1130] [ASTM E1573][ASTM E2638], with measurements and calculations in accordance with ANSI S3.5. Report test results in accordance with the requirements in [ASTM E1130] [ASTM E1573].
o Retest: Correct deficiencies identified by tests and observations, and retest until compliance with specified requirements is achieved.
1-SOW Statement of Work -Furniture Package Wright Patterson AFB, OH
• Baffles (clouds):
o HVAC, Fire suppression, and alarm systems will not be altered. Products to be installed per code and manufacturer guidelines around existing site. Reference
2.4.6 (but not limited to) o Average Horizontal Illumination for open office: 30 footcandle (FC) at 2’-6” AFF. Horizontal Illuminance Uniformity: 2:1 average to minimum (note – some calculations use maximum to average, others maximum to minimum, we need average to min). Contractor to ensure we maintain this proper rating when baffles are installed.
• Carpet:
o Contractor to repair any drywall/ wall surface material that is damaged if existing
4” cove base is not removed properly.
o Contractor to remove existing flooring for all areas within rooms S200 and S226, with the exception of the comm closet. Reference B266, S200 and S226 New attachment, sheets I-5 and I-6 for layouts and section 7.2.1.2 for additional requirements regarding removal o For this project, use of the DAF Mandatory Carpet BPA vehicle shall be incorporated into the solicitation. The Carpet II enterprise-wide vehicles can be met without having to split the efforts into separate solicitations. PCOs would insert language similar to that in attachment A utilizing clauses 52.251-1 GOVERNMENT SUPPLY SOURCES and 252.251-7000 ORDERING FROM
GOVERNMENT SUPPLY SOURCES.
• For this project repair/replace flooring and ceiling, where applicable if damaged upon furniture/ cloud installation of project.
• The Contractor shall provide overall 2D Floor Plan and detailed 3D Image of each typical.
• Optional site visit. Site visit to occur on 15 August 2025 at 10:00 EDT.
For this project we require the following product types: Product Types in Project: systems and modular furniture, seating, storage, modular walls, ceiling clouds, sound masking and flooring.
All workstation storage to be keyed alike per station. No two stations to utilize the same core.
Basis of design: equivalent or better
Workstation- Systems
Typical WS.1
Tag Item Description Finishes
Overall QTY: 106
Room 200: 45 Room 226: 61
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• To come from same manufacturer as WS.1A, WS.1AA, WS.1B, WS.2
• 6’W x 6’L systems workstation
• Panels:
• 3” panel system
• 50”H panels with 12” frosted glass stack. Overall panel height 62”+/-
• Interior: Grade B tackable fabric
• Two integrated, magnetized marker boards
• Span over return (as depicted in rendering above)
• Provide markers and magnetized accessory cup
• Exterior: Wood grain laminate
• Minimum of (4) duplex receptacles (total of 8 plug in points).
**Not to exceed 9 plug in points per station
• Minimum of (1) duplex receptacle (total of 2 plug in points) in beltline above return
• Minimum of (3) duplex receptacles (total of 6 plug in points) in raceway/ and or below worksurface
• Minimum of (2) comm knockouts per station
• Stations to be powered via power pole or base feed. Refer to I-1 and I-2 drawings for locations. Power poles to have separation for comm and electrical. Base feed whips may need to be 6’ to connect to surface mounted junction box. Contractor to confirm once base feeds are installed post award by Government
• Name plate holder for outside of panel
• Acrylic front with accessibility to interchange signage
• Provide template for user to print out inserts
• Signage cannot hang from frosted panel stacker
• Install on laminate front. Not to damage laminate
CONTINUATION ON NEXT PAGE
Not all items in rendering correctly reflect specifications below
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band):
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Cushion top:
• Minimum grade
CONTINUATION Workstation- Systems
Typical WS.1
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Height adjustable desk:
• 2’W x 6’L +/-
• Min weight capacity of 250lbs
• (1) Low profile C or T leg and (1) leg integrated/ concealed in return’s storage
• Extended height adjustment
• Min range: 20”; Max range: 50”
• Simple up/down mechanism only
• Cord length to reach raceway receptable at seated/standing heights
• Minimum of (2) wire management cutouts
• Power strip with minimum of (6) outlets and surge protector
• Mounted below desk (tape is not acceptable)
• Cord length to connect to station panel at standing and seated height
• Cord to be concealed in wire management. Excessive cabling not to hang down
• Wire management
• Below worksurface, tray to be open and easily accessible. Not to close against bottom of worksurface
• Vertical wire carrier to be installed from surface and connected to height adjustable leg. No excessive cabling to hang on floor
• 3mm thick edge band that matches worksurface
• Pivot pencil tray
• Privacy screen:
• Dimensions:
• To span length of desk
• Height above desk: 22”+/-
• Not to hang more than 12” below surface.
• Mounting
• Mounted to edge/below surface. Not on surface top
• Screens to be secure and not wobble
• Bracket mount
• Mounting tape is NOT acceptable
• Screen to raise and lower with desk
• ½”+/- wire gap
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band):
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Cushion top:
• Minimum grade
Overall QTY: 106
Room 200: 45 Room 226: 61
CONTINUATION ON NEXT PAGE
Not all items in rendering correctly reflect specifications below
Typical WS.1
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Dual monitor arm
• Grommet mounted or clamp on (not to interfere with privacy screen)
• Single post with dual array and sliders
• Height adjustable
• Minimum 10-year warranty
• Mobile pedestal file
• Min: 17”D x 14”W x 20”H, Max: 19”D x 16”W x 24” H
• Pencil drawer
• Cushion top
• Locking
• Clamp on power unit:
• Minimum (2) power receptacles
• Minimum (1) USB A + C
• Return:
• 16” W x 54”L +/-
• Height to align with desk (two tops acceptable) or banquette height
• 3mm thick edge band that matches worksurface
• Combination open and closed storage
• Closed storage to be locking
• Coat tower:
• Min: 11”W x 48”H, Max: 13”W x 50”H. Depth to align with return
• Finished back
• Coat rod
• Coat/ bag hook
• Pull
• Locking
Overall QTY: 106
Room 200: 45 Room 226: 61
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band):
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Cushion top:
• Minimum grade
Workstation- Administration Systems
Typical WS.1A
Tag Item Description Finishes
Overall QTY: 3
Room 226: 3
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• To come from same manufacturer as WS.1, WS.1AA, WS.1B, WS.2
• 6’W x 6’L systems workstation
• Panels:
• 3” panel system
• Spline: 50”H panels with 12” frosted glass stack. Overall panel height
62”+/-
• Desk approach: 42”H+/-
• Transaction top to span length of desk
• Interior: Grade B tackable fabric
• Two integrated, magnetized marker boards
• Span over return (as depicted in rendering above)
• Provide markers and magnetized accessory cup
• Exterior: Wood grain laminate
• Minimum of (4) duplex receptacles (total of 8 plug in points).
**Not to exceed 9 plug in points per station
• Minimum of (1) duplex receptacle (total of 2 plug in points) in beltline above return
• Minimum of (3) duplex receptacles (total of 6 plug in points) in raceway/ and or below worksurface
• Minimum of (2) comm knockouts per station
• Stations to be powered via power pole. Refer to I-2 drawing for locations.
Power poles to have separation for comm and electrical.
• Name plate holder for outside of panel
• Acrylic front with accessibility to interchange signage
• Provide template for user to print out inserts
• Signage cannot hang from frosted panel stacker
• Install on laminate front. Not to damage laminate
CONTINUATION ON NEXT PAGE
Not all items in rendering correctly reflect specifications below
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band):
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Minimum grade
CONTINUATION Administration Systems
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Height adjustable desk:
• 2’W x 6’L +/-
• Min weight capacity of 250lbs
• (1) Low profile C or T leg and (1) leg integrated/ concealed in return’s storage
• Extended height adjustment
• Min range: 20”; Max range: 50”
• Simple up/down mechanism only
• Cord length to reach raceway receptable at seated/standing heights
• Minimum of (2) wire management cutouts
• Power strip with minimum of (6) outlets and surge protector
• Mounted below desk (tape is not acceptable)
• Cord length to connect to station panel at standing and seated height
• Cord to be concealed in wire management. Excessive cabling not to hang down
• Wire management
• Below worksurface, tray to be open and easily accessible. Not to close against bottom of worksurface
• Vertical wire carrier to be installed from surface and connected to height adjustable leg. No excessive cabling to hang on floor
• 3mm thick edge band that matches worksurface
• Pivot pencil tray
• Fixed surface “gap cover” with long grain applied. To be stationary between height adjustable desk and panel. Entire desk cannot raise and lower, it would conflict with the transaction top. When height adjustable desk is at seated height, the fixed surface will align and there will not be a gap of “dead space”. To span length of desk and remaining depth to gallery panel
• To maintain at minimum, 42” from the desk edge front to the back panel
CONTINUATION ON NEXT PAGE
Typical WS.1A
Overall QTY: 3
Room 226: 3
Not all items in rendering correctly reflect specifications below
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band) and transaction top:
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Minimum grade 3
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Dual monitor arm
• Grommet mounted or clamp on (not to interfere with transaction top)
• Single post with dual array and sliders
• Height adjustable
• Minimum 10-year warranty
• Mobile pedestal file
• Min: 17”D x 14”W x 20”H, Max: 19”D x 16”W x 24” H
• Pencil drawer
• Cushion top
• Locking
• Clamp on power unit:
• Minimum (2) power receptacles
• Minimum (1) USB A + C
• Return:
• 16” W x 54”L +/-
• Height to align with desk (two tops acceptable) or banquette height
• 3mm thick edge band that matches worksurface
• Combination open and closed storage
• Closed storage to be locking
• Coat tower:
• Min: 11”W x 48”H, Max: 13”W x 50”H. Depth to align with return
• Finished back
• Coat rod
• Coat/ bag hook
• Pull
• Locking
Typical WS.1A
Overall QTY: 3
Room 226: 3
Not all items in rendering correctly reflect specifications below
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band) and transaction top:
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
Workstation- Administration Systems
Typical WS.1AA
Tag Item Description Finishes
Overall QTY: 1
Room 226: 1
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• To come from same manufacturer as WS.1, WS.1A, WS.1B, WS.2
• *DIFFERENCE BETWEEN WS.1A AND WS.1AA IS THE ADDITION OF A WING PANEL ALONG RETURN
AND BASE FEED
• 6’W x 6’L systems workstation
• Panels:
• 3” panel system
• Spline: 50”H panels with 12” frosted glass stack. Overall panel height
62”+/-
• Desk approach: 42”H+/-
• Transaction top to span length of desk
• Interior: Grade B tackable fabric
• Two integrated, magnetized marker boards
• Span over return (as depicted in rendering above)
• Provide markers and magnetized accessory cup
• Exterior: Wood grain laminate
• Minimum of (4) duplex receptacles (total of 8 plug in points).
**Not to exceed 9 plug in points per station
• Minimum of (1) duplex receptacle (total of 2 plug in points) in beltline above return
• Minimum of (3) duplex receptacles (total of 6 plug in points) in raceway/ and or below worksurface
• Minimum of (2) comm knockouts per station
• Station to be powered via base feed. Refer to I-2 drawing for location
• Name plate holder for outside of panel
• Acrylic front with accessibility to interchange signage
• Provide template for user to print out inserts
• Signage cannot hang from frosted panel stacker
• Install on laminate front. Not to damage laminate
CONTINUATION ON NEXT PAGE
Not all items in rendering correctly reflect specifications below
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band) and transaction top:
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Height adjustable desk:
• 2’W x 6’L +/-
• Min weight capacity of 250lbs
• (1) Low profile C or T leg and (1) leg integrated/ concealed in return’s storage
• Extended height adjustment
• Min range: 20”; Max range: 50”
• Simple up/down mechanism only
• Cord length to reach raceway receptable at seated/standing heights
• Minimum of (2) wire management cutouts
• Power strip with minimum of (6) outlets and surge protector
• Mounted below desk (tape is not acceptable)
• Cord length to connect to station panel at standing and seated height
• Cord to be concealed in wire management. Excessive cabling not to hang down
• Wire management
• Below worksurface, tray to be open and easily accessible. Not to close against bottom of worksurface
• Vertical wire carrier to be installed from surface and connected to height adjustable leg. No excessive cabling to hang on floor
• 3mm thick edge band that matches worksurface
• Pivot pencil tray
• Fixed surface “gap cover” with long grain applied. To be stationary between height adjustable desk and panel. Entire desk cannot raise and lower, it would conflict with the transaction top. When height adjustable desk is at seated height, the fixed surface will align and there will not be a gap of “dead space”. To span length of desk and remaining depth to gallery panel
• To maintain at minimum, 42” from the desk edge front to the back panel
CONTINUATION ON NEXT PAGE
Not all items in rendering correctly reflect specifications below
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band) and transaction top:
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Cushion top:
• Minimum grade 3
Typical WS.1AA
Overall QTY: 1
Room 226: 1
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Dual monitor arm
• Grommet mounted or clamp on (not to interfere with privacy screen)
• Single post with dual array and sliders
• Height adjustable
• Minimum 10-year warranty
• Mobile pedestal file
• Min: 17”D x 14”W x 20”H, Max: 19”D x 16”W x 24” H
• Pencil drawer
• Cushion top
• Locking
• Clamp on power unit:
• Minimum (2) power receptacles
• Minimum (1) USB A + C
• Return:
• 16” W x 54”L +/-
• Height to align with desk (two tops acceptable) or banquette height
• 3mm thick edge band that matches worksurface
• Combination open and closed storage
• Closed storage to be locking
• Coat tower:
• Min: 11”W x 48”H, Max: 13”W x 50”H. Depth to align with return
• Finished back
• Coat rod
• Coat/ bag hook
• Pull
• Locking
Not all items in rendering correctly reflect specifications below
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band) and transaction top:
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Cushion top:
• Minimum grade 3
Typical WS.1AA
Workstation- Systems
Typical WS.1B
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• To come from same manufacturer as WS.1, WS.1A, WS.1AA and WS.2 *DIFFERENCE BETWEEN WS.1 AND WS.1B IS THE ADDITION OF A WING PANEL ALONG RETURN AND
WILL ONLY BE POWERED VIA BASE FEED
• 6’W x 6’L systems workstation
• Panels:
• 3” panel system
• 50”H panels with 12” frosted glass stack. Overall panel height 62”+/-
• Interior: Grade B tackable fabric
• Two integrated, magnetized marker boards
• Span over return (as depicted in rendering above)
• Provide markers and magnetized accessory cup
• Exterior: Wood grain laminate
• Minimum of (4) duplex receptacles (total of 8 plug in points).
**Not to exceed 9 plug in points per station
• Minimum of (1) duplex receptacle (total of 2 plug in points) in beltline above return
• Minimum of (3) duplex receptacles (total of 6 plug in points) in raceway/ and or below worksurface
• Minimum of (2) comm knockouts per station
• Stations to be powered via base feed. Refer to I-2 drawing for locations.
Base feed whips may need to be 6’ to connect to surface mounted junction box. Contractor to confirm once base feeds are installed post award by Government
• Name plate holder for outside of panel
• Acrylic front with accessibility to interchange signage
• Provide template for user to print out inserts
• Signage cannot hang from frosted panel stacker
• Install on laminate front. Not to damage laminate
CONTINUATION ON NEXT PAGE
Overall QTY: 8
Room 226: 8
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band):
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Cushion top:
• Minimum grade 3
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Height adjustable desk:
• 2’W x 6’L +/-
• Min weight capacity of 250lbs
• (1) Low profile C or T leg and (1) leg integrated/ concealed in return’s storage
• Extended height adjustment
• Min range: 20”; Max range: 50”
• Simple up/down mechanism only
• Cord length to reach raceway receptable at seated/standing heights
• Minimum of (2) wire management cutouts
• Power strip with minimum of (6) outlets and surge protector
• Mounted below desk (tape is not acceptable)
• Cord length to connect to station panel at standing and seated height
• Cord to be concealed in wire management. Excessive cabling not to hang down
• Wire management
• Below worksurface, tray to be open and easily accessible. Not to close against bottom of worksurface
• Vertical wire carrier to be installed from surface and connected to height adjustable leg. No excessive cabling to hang on floor
• 3mm thick edge band that matches worksurface
• Pivot pencil tray
• Privacy screen:
• Dimensions:
• To span length of desk
• Height above desk: 22”+/-
• Not to hang more than 12” below surface.
• Mounting
• Mounted to edge/below surface. Not on surface top
• Screens to be secure and not wobble
• Bracket mount
• Mounting tape is NOT acceptable
• Screen to raise and lower with desk
• ½”+/- wire gap
CONTINUATION ON NEXT PAGE
Typical WS.1B
Overall QTY: 8
Room 226: 8
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band):
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Cushion top:
• Minimum grade 3
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Dual monitor arm
• Grommet mounted or clamp on (not to interfere with privacy screen)
• Single post with dual array and sliders
• Height adjustable
• Minimum 10-year warranty
• Mobile pedestal file
• Min: 17”D x 14”W x 20”H, Max: 19”D x 16”W x 24” H
• Pencil drawer
• Cushion top
• Locking
• Clamp on power unit:
• Minimum (2) power receptacles
• Minimum (1) USB A + C
• Return:
• 16” W x 54”L +/-
• Height to align with desk (two tops acceptable) or banquette height
• 3mm thick edge band that matches worksurface
• Combination open and closed storage
• Closed storage to be locking
• Coat tower:
• Min: 11”W x 48”H, Max: 13”W x 50”H. Depth to align with return
• Finished back
• Coat rod
• Coat/ bag hook
• Pull
• Locking
Typical WS.1B
Overall QTY: 8
Room 226: 8
• Panels and privacy screen:
• Interior-Minimum grade B woven, with min of 10 patterns
• Exterior: Woodgrain laminate: Minimum 12 options
• Trim: Minimum of 6 metal options
• Work surface (with matching edge band):
• Minimum of 12 HPL wood grain options
• Supports and storage:
• Minimum of 6 metal options
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh, metal or PET
• Cushion top:
• Minimum grade 3
Boss Box- Systems with Modular Furniture
Typical WS.2
Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• 8’-0” x 8’-0” systems workstation
• Panels:
• 3” panel system
• Min Overall: 79”H; Max Overall: 84”H
• Frosted glass stack:
• Min: 14”H; Max: 19”H
• Interior:
• Tackable fabric
• (A) Integrated markerboard
• 30”H +/-
• Magnetized
• Provide accessory cup and markers
• Exterior: Wood grain laminate
• Stations to be powered via power pole. Refer to I-1 and I-2 drawings for locations.
Power poles to have separation for comm and electrical.
• Minimum of (3) duplex receptacles (total of 6 plug in points). Not to exceed 8 plug in points.
• Minimum of (1) duplex receptacles (total of 2 plug in points) in beltline above worksurface
• Minimum of (2) duplex receptacles (total of 4 plug in points) in raceway below surface
• Minimum of (1) comm knock out
• Sliding door
• 36”W
• Frosted
• Locking. Not to lock into floor
• Bar pull
• Name plate holder for outside of panel
• Acrylic front with accessibility to interchange signage
• Provide template for user to print out inserts
• Signage cannot hang from frosted panel stacker
• Install on laminate front. Not to damage laminate
CONTINUATION ON NEXT PAGE
Not all items in rendering correctly reflect specifications below
A A
AA
X X
Overall QTY: 26
Room 200: 11 Room 226: 15
• Panels:
• Interior-Minimum grade B woven, with min of 10 patterns
• White magnetized markerboard
• Exterior- Wood laminate, minimum of 15 wood laminate options
• Frosted glass stack
• Trim: Minimum grade
B, powder coated
• Work surface, modesty, storage and shelf:
• Minimum of 15 wood grain HPL laminate options
• Matching edge band
• Supports, storage and base:
• Minimum of 5 metal
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh or PET
• Task light:
• Minimum 3 metal options
CONTINUATION Boss Box- Systems with Modular Furniture
Typical WS.2
Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
CONTINUATION ON NEXT PAGE
Not all items in rendering correctly reflect specifications below
Overall QTY: 26
Room 200: 11 Room 226: 15
• T-shape
• Height adjustable desk
• Desk: 2’W x 5’L +/-
• Adjustable telescoping leg. Box shroud and post adjustable leg are not acceptable
• Min weight capacity of 250lbs
• Minimum of (2) grommets
• 3mm thick edge band that matches worksurface
• 1/3-1/2 modesty panel
• Pivot pencil tray
• Clamp on power unit
• Minimum (2) power receptacles
• Minimum (1) USB A + C
• Dual monitor arm
• Grommet mounted or clamp on (not to interfere with modesty panel)
• Single post with dual array and sliders
• Height adjustable
• Minimum 10-year warranty
• Dimmable LED desk light
• One touch dimmable feature
• Energy-saving occupancy sensor
• Counterbalance arm which rotates up to 180 degrees
• Power strip with minimum of (6) outlets and surge protector
• Mounted below desk (tape is not acceptable)
• Cord length to connect to station panel at standing and seated height
• Cord to be concealed in wire management. Excessive cabling not to hang down
• Wire management
• Below worksurface, tray to be open and easily accessible. Not to close against bottom of worksurface
• Vertical wire carrier to be installed from surface and connected to height adjustable leg. No excessive cabling to hang on floor
• Panels:
• Interior-Minimum grade B woven, with min of 10 patterns
• White magnetized markerboard
• Exterior- Wood laminate, minimum of 15 wood laminate options
• Frosted glass stack
• Trim: Minimum grade
B, powder coated
• Work surface, modesty, storage and shelf:
• Minimum of 15 wood grain HPL laminate options
• Matching edge band
• Supports, storage and base:
• Minimum of 5 metal
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh or PET
• Task light:
Boss Box- Systems with Modular Furniture
Typical WS.2
Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
Not all items in rendering correctly reflect specifications below
Overall QTY: 26
Room 200: 11 Room 226: 15
• Return: 2’W x 6’-6”+/- (to match footprint of I-1 drawing)
• Align with height of desk when at seated height
• 3mm thick edge band that matches worksurface
• Closed storage flanking desk
• Lateral file
• Box/box/file
• Pencil drawer
• Pulls
• Locking
• Overhead and shelf
• Overhead to span over lateral file (30”+/-). Height to align with wardrobe
• Mounted to panel
• Sliding door(s)
• Locking
• Shelf to span full length between overhead and wardrobe. Height to align with wardrobe
• Mounted to panel (not freestanding)
• Laminate/wood back (as depicted above in image)
• Combination wardrobe cabinet
• Min: 23”D x 23”W x 70”H; Max: 25”D x 25”W x 74”H
• Soft close on all drawers and doors if available
• Full length coat storage:
• Hanging bar
• Coat hook
• Pull
• Locking
• Storage tower
• Adjustable shelving
• File/file or box/box/ file below
• Pulls
• Locking
• Panels:
• Interior-Minimum grade B woven, with min of 10 patterns
• White magnetized markerboard
• Exterior- Wood laminate, minimum of 15 wood laminate options
• Frosted glass stack
• Trim: Minimum grade
B, powder coated
• Work surface, modesty, storage and shelf:
• Minimum of 15 wood grain HPL laminate options
• Matching edge band
• Supports, storage and base:
• Minimum of 5 metal
• Pulls on storage fronts:
• Minimum of 2 metal options
• Wire management basket:
• Mesh or PET
• Task light:
Lateral File with Common Top
Typical L.1
Tag Item Description
• Metal:
• Minimum of
(8) metal sections
• Common Top:
• Minimum of
12 TFL or HPL selections
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Minimum: 17” W x 40”L x 37”H
• Maximum: 19” W x 48”L x 42”H
• Locking
• Hanging rails
• Individual laminate common top (not shared between the units) ** Image does not depict common top
Finishes
Overall QTY: 15
Room 200: 6 Room 226: 9
Seating- Multipurpose
Typical S.2
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Nesting
• Mid-back
• Mesh back
• Upholstered seat
• Fixed angled arms integrated from the chair back down to the base
• Weight activated back tilt
• 4 angled leg, double caster base
• 300lb minimum weight capacity
• 15 year, 24/7 warranty
• Mesh back:
• Minimum of
8 options
• Upholstered seat:
• Minimum grade 3
• Frame:
• Minimum of
3 options.
Fog and white to be option
Sit On It, Movi is depicted
Overall QTY: 68
Room 200: 38 Room 226: 30
Seating-Bar Stool
Typical S.3
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Upholstery:
• Minimum grade F
• Wood Back:
• Minimum of 5 selections
• Metal Base:
• Minimum of
4 selections
JSI, Knox is depicted
• To come from same manufacturer as S.3A
• To fit appropriately below T. 2
• Minimum overall: 17”D x 18”W
• Maximum overall: 19”D x 20”W
• Bar height
• Armless
• Upholstered seat
• Wood back (no cut outs)
• (4) Metal legs with glides
• Footrest
• Minimum of 250lb weight capacity
Overall QTY: 8
Room 200: 4 Room 226: 4
Seating-Stool
Typical S.3A
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
JSI, Knox is depicted
• To come from same manufacturer as S.3
• To fit appropriately below T. 3
• Minimum overall: 17”D x 18”W
• Maximum overall: 19”D x 20”W
• Standard height
• Armless
• Upholstered seat
• Wood back (no cut outs)
• (4) Metal legs with glides
• Footrest
• Minimum of 250lb weight capacity
Overall QTY: 4
Room 226: 4
• Upholstery:
• Minimum grade F
• Wood Back:
• Minimum of 5 selections
• Metal Base:
• Minimum of
4 selections
Seating- Lounge
Typical S.4
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Upholstery:
• Minimum grade F
• Base:
• Minimum of 5 wood selections
• MCM moulded back and arms lounge
• Minimum overall: 27”W x 27”D x 31”H
• Maximum overall: 30”W x 30”D x 34”H
• Low-mid back
• Fully upholstered
• Angled arms integrated into back and seat (no wood/ metal trim)
• Four-legged angled base or four-prong swivel base
• Wood
• Wall saver
• Minimum of 300lb weight capacity
Encore, Melina and Kimball, Superkool are depicted
Overall QTY: 2
Room 226: 2
Seating, Sofa
Typical S.5
Tag Item Description Finishes
For Government Use OnlyMeets
Reason(s) does not meet:
Basis of design: equivalent or better
Does Not Meet
• 2-seated sofa
• Overall: 70”W x 35”D x 34”H +/-
• Fully upholstered
• Straight track or slopped arms
• Arms connected to frame
• Seat cushions attached to frame
• Back pillows attached to back frame
• Base options:
• Low profile square legs (wood or metal)
• U-shaped base (metal)
Overall QTY: 1
Room 226: 1
• Upholstery:
• Minimum grade F
• Base:
• Minimum of 5 wood selections
Kimball, Collette is depicted
Table- Conference Room
Typical T.1
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• 3’ x 8’ +/- table
• Standard height
• Levitating top
• Solid wood legs with metal brace connecting to levitating top
• Ellora integrated power unit
• Flush close door
• 2 power receptacles/1 data openings/2 USB A+
• Cable(s) to reach to building power
• Wire management below table. Easily accessible
• To hold minimum of (2) electrical cords and (1) comm cable
• Provide organized routing in table leg to floor power. Reference typical MW.1 for additional specifications
• Surface:
• Minimum of
12 HPL
options
• Base:
• Minimum of
4 metal options
Overall QTY: 2
Room 200: 2
Enwork, Ligori is depicted
Table- Parsons
Typical T.2
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Parsons table
• To come from same manufacturer as T.3
• Bar height:
• Min: 16”D x 116”W; Max: 20”D x 122”W (one piece top)
• HPL laminate top
• HPL or wood sides/ supports
• Modesty panel only for structural support
• (2) Flush mount power units per table
• Include minimum of (2) power receptacles and
(1) knock out for comm cable
• Wire management below table. Easily accessible
• To hold minimum of (4) cords
• Top/ supports:
• Minimum of
12 HPL
selections and or matching veneer
Overall QTY: 2
Room 200: 1
Table- Parsons
Typical T.3
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Parsons table
• To come from same manufacturer as T.2
• Standard height:
• Min: 16”D x 116”W; Max: 20”D x 122”W (one piece top)
• HPL laminate top
• HPL or wood sides/ supports
• Modesty panel only for structural support
• (2) Flush mount power units
• Include minimum of (2) power receptacles and
(1) knock out for comm cable
• Wire management below table. Easily accessible
• To hold minimum of (4) cords
Overall QTY: 1
Room 226: 1
• Top/ supports:
• Minimum of
12 HPL
selections and or matching veneer
Break Area-Casework
Typical BA.1
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Chassis and doors:
• Minimum
12 wood grain HPL or
TFL
selections
• Countertop and backsplash:
• Minimum grade 2 solid surface
• Base and wall hung cabinets
• To come from same manufacturer as BA.2
• 108”W +/- Reference I-1 drawing for layout
• Floor mounted base cabinets:
• 30”D x 36”H+/-
• Full overlay, hinged doors
• NO wire pulls, bar pull or modern pull
• Soft close doors
• Solid surface countertop with backsplash
• 4” vinyl cove base toe kick (can coordinate with
FL.2)
• Upper cabinets:
• Full overlay, hinged doors
• NO wire pulls, bar pull or modern pull
• Soft close doors
• Flat top
• Include all necessary installation items to accommodate base and upper cabinets to building wall and floor
Break Area-Casework
Typical BA.2
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Chassis and doors:
• Minimum
12 wood grain HPL or
TFL
selections
• Countertop and backsplash:
• Minimum grade 2 solid surface
• Base and wall hung cabinets
• To come from same manufacturer as BA.1
• “L-Shaped”
• Dimensions noted above +/-
• Floor mounted base cabinets:
• 30”D x 36”H+/-
• Full overlay, hinged doors
• NO wire pulls, bar pull or modern pull
• Soft close doors
• Solid surface countertop with backsplash
• 4” vinyl cove base toe kick (can coordinate with
FL.2)
• Upper cabinets:
• Fit in accordance to I-2 drawing (screen shot above)
• Full overlay, hinged doors
• NO wire pulls, bar pull or modern pull
• Soft close doors
• Flat top
• Include all necessary installation items to accommodate base and upper cabinets to building wall and floor
Waste Bin-Personal
Typical WB.1
Tag Item Description Finishes
QTY: 150
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Black plastic• 7 gallon plastic waste bin
• 14” x 10” x 15”H +/-
• Rolled rim
• To be installed at every workstation, boss box, collaboration space and team room
Waste Bin-Communal
Typical WB.2
Tag Item Description Finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Minimum of 3 metal options
• 38 gallon waste receptacle
• Sloped top with square opening for trash
• Integrated bag arm
• Adjustable glides
• Metal
Magnuson Group, Slope is depicted
Overall QTY: 2
Stationary Privacy Screen
Typical SS.1
Tag Item Description
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• To come from same manufacturer as SS.2
• Suspended privacy screen with laser cut outs
• Min: 46”W x 90”H
• Max: 50”W x 95”H
• Top mount
• Anchored into ceiling and floor. Contractor to provide all manufacturer specified items to securely install to facility
• Minimum 9 mm PET
• Minimum of (5) PET laser patterns
Finishes
Overall QTY: 2
Room 200: 1 Room 226: 1
• PET:
• Minimum of 18 color
Turf, Static Screen is depicted
Stationary Privacy Screen
Typical SS.2
Tag Item Description
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• To come from same manufacturer as SS.1
• Suspended privacy screen with laser cut outs
• Min: 80”W x 90”H
• Max: 88”W x 95”H
• Top mount
• Anchored into ceiling and floor. Contractor to provide all manufacturer specified items to securely install to facility
• Minimum 9 mm PET
• Minimum of (5) PET laser patterns
Finishes
Overall QTY: 1
Room 226: 1
• PET:
• Minimum of 18 color
Turf, Static Screen is depicted
Modular Wall- Team Room
Typical MW.1
Tag Item Description
• Modular walls:
• Interior:
• Minimum grade B woven upholstery or minimum of
(5) wood grain laminate options
• Exterior:
• Clear glass with frosted film
• Trim:
• Minimum of
(2) metal options
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• To come from same manufacturer as MW.2
• Approximate footprint is 12’W x 23’L
• Reference I-1 drawing for dimensions and location
• Ceiling height 9’-5”
• Modular wall height to fall 18” below ceiling. Min height: 90”; Max height: 95”
• Interior:
• A) Television (provided by Government) to be mounted to wall. Provide items necessary for anchoring tv. Provide mount.
• Either woven or wood grain laminate
• B) Top and bottom woven or wood grain laminate (to match central monitor area).
Center, 36”H+/- integrated magnetized markerboard at average standing height.
Provide markers and accessory cup
• Exterior:
• C) Glass with 36”+/- frosted film. Film installed to create privacy when users are seated
• Walls to be structurally sound:
• Can anchor into floor
• Excessive airplane cabling is not acceptable
• No cross-beam structures
• Power pole/beams acceptable
• Connect to building’s drywall and columns where applicable
• (2) Sliding doors:
• Bar pull
• Glass with 36”+/- frosted film. Film installed to create privacy when users are seated.
Film to align with walls
• Soft close
• Electrical and Comm:
• Total of (4) duplex receptacles (8 plug in points).
• (1) duplex behind tv screen (per side)
• (1) duplex near raceway (per side)
• Provide (2) comm knock outs
• Provide power poles for electrical/ cabling. Power poles to have separation for comm and electrical. Reference I-1 drawing for locations
• Floor raceway power with wire management:
• Low profile, concealed under carpet raceway with exposed power/comm below table (T.1). Raceway to connect to modular wall and run below T.1. Minimum (2) plug in points and comm knock out
Finishes
Overall QTY: 1
Room 200: 1
A A
B B
B B
C
C
EXISTING DEMOUNTABLE WALL
Legrand, Express Kit is depicted
Modular Wall
Typical MW.2
Tag Item Description
• Modular walls:
• Exterior:
• Clear class with frosted film
• Trim:
• Minimum of
(2) metal options
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• To come from same manufacturer as MW.1
• Approximate footprint is 5’-2”W
• Reference I-1 drawing for dimensions and location
• Ceiling height 9’-5”
• Modular wall or systems panel height to fall 18” below ceiling. Min height: 90”; Max height: 95”
• Exterior:
• Glass with 36”+/- frosted film. Film installed to create privacy when users are seated
• Walls to be structurally sound:
• Can anchor into floor
• Excessive airplane cabling is not acceptable
• No cross-beam structures
• Power pole/beams acceptable
• Connect to building’s drywall and columns where applicable
• Hinged door:
• Bar pull
• Glass with 36”+/- frosted film. Film installed to create privacy when users are seated.
Film to align with walls
• Soft close if applicable
Finishes
Privacy Pod- 4 Person
Typical P.2
Tag Item Description Finishes
• Minimum 30dB interior sound proofing
• Sealed and fully enclosed unit (open threshold not acceptable)
• Dimensions:
• Exterior minimum: 91”W x 50”D x 89”H. Exterior maximum: 87”W x 92”D x 92”H
• Exterior:
• Radius exterior corners
• Powder coated panels
• Door
• Door handle. Latch to strike plate to release the door. Guaranteed seal
• Interior
• Motion activated circulation fan
• Motion activated light(s)
• Minimum of one ceiling light. Dimmable
• (2) fixed love seats
• Span majority of pod’s depth
• Width to fit in accordance with table
• Fully upholstered
• 4 leg or plinth base
• Peninsula table
• Minimum: 27”W x 35”L
• Laminate
• Minimum (1) power receptacle and (1) Communication knock out
• Interior panel construction PET or polyester
• Interior carpet
• Stain resistant
• 36” +/- H frosted band. To be installed centrally at seated height on both sides with glass, to add privacy
• Easily movable
• GREENGUARD Gold certified
• Minimum of a 10’ cord
• Require dedicated power pole on workstations to accommodate privacy pod. Plug and play (receptacle on power pole) and channel for communication cabling. Pole to have separation.
• Minimum of 5-year warranty
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
Framery, Four is depicted
• Exterior:
• Need to provide minimum of black white and blue options
• Black trim
• Interior:
• Walls- Minimum of 2 color options
• Flooring- Minimum of 2 color options
• Seating: Minimum of 2 color options
• Stain resistant
• Table: Minimum of 2 HPL/TFL options
Example of frosted band
Overall QTY: 3
Room 200: 2
Window Treatment, Roller Shades
Tag Item Description Finishes
• Provide and install new roller shade
• Include facia, hardware and pull
• Window is approximately 57”W x 88”H
• Minor variants per window
• Woven
• Metal fascia
• Manual pull (chain)
• Sun control shade:
• 3% openness
• Minimum of 95% UV blockage
• Bacteria and fungal resistance
• Greenguard certified
• Polyester, vinyl, polyester or combination or the three mentioned materials
• White backing
• Fire Classification-NFPA 701
• Minimum of 10-year warranty
• Existing mini blinds, fascia and any corresponding hardware to be demoed. Some areas have curtains which are to remain. Reference section 7.2 of the SOW for additional information.
• Draper/ Phifer/ Mecho Shade, equivalent or better
• Provide white, off white and light gray finish selections
• Fascia:
• Minimum of 2 metal finishes
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
Basis of design: equivalent or better
Typical WT.1
Overall QTY: 58
Room 200: 26 Room 226: 32
Ceiling Baffles- Cloud
Typical BF.1
Tag Item Description Finishes
• “Waffle” cloud
• Square or softened circular shape
• Hatched with openings. Not solid cloud shape
• Minimum: 46”L x 46” W x 6”H
• Maximum: 53”L x 53” W x 12”H
• Minimum NRC rating of .5
• Minimum of 9 mm HPD
• ASTM E84 Class A
• PET
• Minimum 50% post- consumer recycled content
• Intermix minimum of 2 colors
• Installation:
• Refer to I-3 and I-4 for reflected ceiling plan and cloud location
• To be hung level and parallel
• Ceiling height: Dropped ceiling with 24”x 48” in-lay tiles
• Approximately 9’-5”
• Top of cloud to hang 10”+/- below ceiling grid
• Airplane cabling or commercial heavy-duty cabling per manufacturer’s guidelines
• Baffles not to sway
For Government Use OnlyMeets Does Meets
Reason(s) does not meet:
• PET:
• Minimum of 18 color options
Overall QTY: 94
Room 200: 39 Room 226: 55
Basis of design Lencore, Logison, equivalent or better
Sound Masking
Typical SM.1
Tag Item Description Finishes
• White noise sound masking for rooms S200 and S226
• Overall quantity takes into consideration the two room locations. Not the individual speaker count
• To coordinate with baffles and new furniture layout
• Flush mount
• Ceiling height (floor to grid) 9’-5”
• Height above grid needs to be confirmed, however approximately 2’ from finished ceiling to deck
• Variable sound levels
• Full range speakers
• Network control panel. To be installed in comm closet. Single, system control for entire project scope by providing operation of multiple system zoning components from a single, central location
• Control Panel should be 1RU or 2RU maximum.
• Connections Comply with UL 60065
• Power Supply: NFPA 70, Class 2
• Ethernet Connection: TIA 485
• Serial Connection: RS-232 port
• Output to Loudspeaker Control Units: NFPA 70, Class 2
• Full Masking Spectrum Capable between 100-10,000 Hz, Scalable to Accommodate all Size Facility (single office to multi building campus), Reconfigurable for Expansion, In Room Control and Software Control Capable
• All programming of the Sound Masking Network shall be handled by the manufacturer
• Paging and or music applications are not required for this project
• Minimum 10-year warranty
• Reference section 1.0 of the SOW for additional specifications
For Government Use OnlyMeets Does Meets
Reason(s) does not meet:
• White
Overall QTY: 1
Located in rooms S200 and S226
Flooring- Carpet
Typical FL.1
Tag Item Description
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Utilize the Air Force Carpet II Program for carpet and adhesive
• Interface: Streaming collection, Bitrate, color: Dark Aqua
• 4” or 4 1/2” rubber cove base (contractor to verify site once existing is removed). Color TBD
• To conceal any discolored drywall/ wall once existing cove is removed
• Vinyl transition strips to be installed at areas where flooring (existing or new) will not be level. Color TBD
• Removal and disposal of existing carpet to occur off base by contractor. Items to be recycled in reclamation program
• Patch and prep flooring
• Carpet backing will be slightly lower than existing carpet. Contractor to feather impacted areas.
• *Mounding up floor leveling is not an appropriate means or method
• Private office and conference room furniture to remain as is. Contractor to lift/ jack up the existing furniture to demo existing carpet and install new.
• Manufacturer specified pressure sensitive adhesive
• Backing: Glass Back: CQuest GB
• Installation method: 45-degree ashlar
• Reference B266 Rooms S200 and S226 attachment, sheets I-5 and I-6 for directional location, flooring takeoff/layout.
• Include 5% attic stock
Flooring- LVT
Typical FL.2
Tag Item Description
For Government Use OnlyMeets Does Not Meet
Reason(s) does not meet:
• Interface: Fresco Valley, Ridge, color: Mushroom
• 4” or 4 1/2” rubber cove base (contractor to verify site once existing is removed). Color TBD
• To conceal any discolored drywall/ wall once existing cove is removed
• To coordinate with BA.1 and BA.2
• Vinyl transition strips to be installed at areas where flooring (existing or new) will not be level. Color TBD
• Removal and disposal of existing carpet to occur off base by contractor. Items to be recycled in reclamation program
• Patch and prep flooring
• Manufacturer specified pressure sensitive adhesive
• Size: 19.69” x 19.69”
• Total thickness 4.5mm
• Installation method-quarter turn
• Reference B266 Rooms S200 and S226 attachment, sheets I-5 and I-6 for directional location, flooring takeoff/layout.
• Include 5% attic stock
Once the contract has been awarded, it becomes the responsibility of the contractor to validate the actual site conditions as well as any specific programming needs of the customer.
This is the start of the file's text. The full file is on GovTribe.