Attachment 2 Specifications.pdf

PDF 2 MB Posted

Attached to
Lawton Modular Building Site Federal contract opportunity
Solicitation number
75H70124R00030
Issued by
Department of Health and Human Services Indian Health Service

About this file

This document is an attachment related to a federal contract opportunity solicitation for the construction of a modular office building for the Indian Health Service (IHS) in Lawton, Oklahoma.

The key details are: The project will place a 6-inch concrete footing and slab in preparation for a 9,600 sq. ft. single story modular office building at the Lawton Indian Hospital. The work includes all earthwork, site preparation, exterior improvements, and utilities. This is a 100% Small Business set-aside solicitation under NAICS code 236220 with a $45 million size standard. The period of performance is 60 calendar days. The anticipated construction magnitude is between $250,000 and $500,000. A site visit is scheduled for May 14, 2024. The Government intends to award a Firm Fixed Price construction contract. Quotes are due by the deadline indicated in the SF 1442. Award will be based on conformance to the solicitation requirements, with price as the discriminating factor. All prospective offerors must be registered in the SAM database.

View the file

Other files for this federal contract opportunity

Other files attached to Lawton Modular Building Site, newest first.
File Type Posted
B05 Amendment 1.pdf PDF
Attachment 4 WH347 PAYROLL.pdf PDF
Attachment 5 Release of Claims.pdf PDF
B01 24R00030.pdf PDF
Attachment 7 Past Performance Questionnaire.docx DOCX document
Attachment 6 Specialized Experience Construction Form.docx DOCX document
Attachment 3 Geotech Report.pdf PDF
Attachment 1 Wage Determination OK20240043.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ENERGY DESIGN CRITERIA: SPECIAL CONDITIONS DESIGN CRITERIA:

AND / OR LIMITATIONS:

CODES: 2021 IBC 2022 ASHRAE 170 VHCF

NOTE: UNLESS OTHERWISE NOTED, ALL CODE REFERENCES BELOW ARE TO THE: 2023 NFPA 13 FSD NOTE: 2021 IPC 2022 ASCE 7-22 MDL

MATERIALS WHICH EQUAL OR EXCEED THOSE SPECIFIED 2021 IMC Architectural Barriers Act 1968 CLIMATE ZONE: 3A AS SHOWN IN TABLE: 902.1 (37) MAY BE SUBSTITUTED. 2023 NFPA 70 NEC Whole Building Design Guide

FOR BUILDINGS WITH OVERALL WINDOWS AND GLAZED DOOR OPENINGS 2021 NFPA 1 FC US DOE Fed Energy Mngmnt Policy TOTALING 10% OR LESS OF THE GROSS ABOVE-GRADE WALL AREA. NOTE: 2021 NFPA 101 LSC Energy Policy Act of 2005

BUILDING IS TO BE LOCATED A MINIMUM OF 10 FT. 2022 ASHRAE 90.1 10 CFR Parts 4333, Subpart D,4 & HEATING DEGREE DAYS 3480 COOLING DEGREE DAYS: 2489 FROM PROPERTY LINE OR ASSUMED PROPERTY LINE. 2023 NFPA 13 FSD 435 Subpart

2022 ASHRAE 62.1 State, Local, Tribal Codes

2023 NFPA 13 FSD OCCUPANCY CLASSIFICATION: B

ROOF: ALL WOOD JOIST / TRUSS: R-38 PORTABLE FIRE EXINGUISHERS TO BE PROVIDED AND INSTALLED OCCUPANCY CATEGORY: II

WALL: WOOD FRAMED: R-21 BY OWNER CONSTRUCTION TYPE: V-B

FLOOR: ALL WOOD JOIST / TRUSS: R-30 APPLIANCE FUEL TYPE: NATURAL GAS

WINDOWS ARE

U-FACTOR FOR WINDOWS: DESIGN LOADS:

SHGC FOR WINDOWS:

U-FACTOR FOR DOORS: ROOF LIVE LOAD: 20 PSF

FLOOR LIVE LOAD: 50 PSF

LIGHTING CONTROLS: OCCUPANT SENSOR CONTROLS FOR INTERIOR LIGHTING. CONCENTRATED FLOOR LOAD: 2000 LBS

PHOTOCELL CONTROLS FOR EXTERIOR LIGHTING CORRIDOR FLOOR LOAD: 100 PSF

MANUALLY PROGRAMMABLE TIMER FOR EXTERIOR FLOOD LIGHTS GROUND SNOW LOAD: 10 PSF

GENERAL LIGHTING: LED LIGHT WITH 4800 LUMEN LIGHT MODULE ROOF SNOW LOAD: 10 PSF

RESTROOM LIGHTING: LED LIGHT WITH 4800 LUMEN LIGHT MODULE WIND SPEED Vult: 108 MPH

EXTERIOR LIGHTING: WALL MOUNTED LED LIGHT MODULE ON PHOTOCELL WIND SPEED asd: 90

EXPOSURE: C

SEISMIC DESIGN CATEGORY: C

BUILDING AREA: 9387 S.F.

HVAC EFFICIENCY: WALL HUNG ELECTRIC HEAT PUMP HVAC UNITS: 11.00 EER OCCUPANT LOAD: 94

OCCUPANT AGE GROUP: 18+ YEARS

WATER HEATING COMPONENTS TO COMPLY WITH SECTION 804

SYSTEM CONTROLS: PROGRAMMABLE THERMOSTAT WITH OCCUPANT OVERRIDE PER 803.2.3.1 DRAWING INDEX: SHEET

NOTE: TEMPERATURE OF WATER AT LAVATORIES TO BE

OUTDOOR AIR VENTILATION RATE OF: 2350 2021 IMC DELIVERED THROUGH AN APPROVED DEVICE CONFORMING TO COVER SHEET / SPECIFICATIONS A-1

ASSE 1070 FLOOR PLAN A-2

DUCT INSULATION: WHERE DUCTING IS USED, DUCTS SHALL BE SEPARATED FROM THE EXTERIOR ELEVATIONS A-3

BUILDING EXTERIOR BY A MINIMUM OF R-8 INSULATION. CROSS-SECTION A-4

(NOTE: DUCTING USED BY PALOMAR HAS A MINIMUM R-VALUE OF 5.6, AND INTERIOR ELEVATIONS A-5

IS CONTAINED WITHIN THE BUILDING ENVELOPE.) BLOCKING & TIE-DOWN LAYOUT S-1

NOTE: CHASSIS LAYOUT S-2

DUCT SEALING: DUCTS ARE TO BE SEALED IN ACCORDANCE WITH 803.2.8 OF THE 2023 NFPA 13 FSD BUILDING IS TO BE PROVIDED WITH AN AUTOMATIC FLOOR FRAMING LAYOUT S-3

SPRINKLER SYSTEM DESIGNED AND INSTALLED BY A ROOF FRAMING LAYOUT S-4

NOTE: EXTERIOR HPS OR HALIDE LIGHTS ARE FOR SECURITY PURPOSES ONLY CONTRACTOR LICENSED BY THE : ROOF DRAINAGE LAYOUT S-4.1

ROOF: STATE FIRE MARSHAL RAFTER DETAILS S-5

RIDGE BEAM CONSTRUCTION S-6

DRAIN, WASTE & VENT SYSTEM M-1

NOTES: ACCESSIBILITY REQUIREMENTS: WATER SUPPLY SYSTEM M-2

CEILING GRID / HVAC LAYOUT M-3

DATA PLATE(S) TO BE INSTALLED ON THE COVER OF THE ELECTRICAL DISTRIBUTION PANEL AS NOTED ON SHEET A-2. LIGHTING SCHEMATIC E-1

POWER DISTRIBUTION SCHEMATIC E-2

DECALS TO BE INSTALLED ON THE REAR END, ON THE LOWER LEFT-HAND CORNER OF MODULES WITH METAL SIDING. ELECTRICAL LOAD CALCULATIONS E-3 BUILDINGS WITH SIDINGS WHICH ARE TO BE PAINTED AS A PART OF ROUTINE MAINTENANCE, THE DECALS ARE TO BE LOCATED ON THE REAR END WALL OF THE MODULE, NEAR THE MATELINE, ABOVE THE SUSPENDED CEILING TILE.

BUILDING WITH PAINTABLE SIDINGS AND HARD CEILINGS ARE TO HAVE THE DECALS LOCATED AS NOTED ON A-2.

NOTE:

PER SECTION 506.2.1 OF THE 2021 IBC WHERE A SINGLE STORY, SINGLE OCCUPANCY BUILDING HAS A MINIMUM HANDICAP ACCESSIBLE RAMP TO BE INSTALLED 25% OF THE PERIMETER OF THE BUILDING IS FACING A YARD OR PUBLIC WAY, THE MAXIMUM ALLOWABLE AREA OF THE BY OTHERS IN ACCORDANCE WITH THE A.D.A.

BUILDING IS PERMITTED TO BE INCREASED IN ACCORDANCE WITH EQUATION 5-1, EQUATION 5-1 STATES Aa=At + (NS X If), GUIDELINES.

WHERE Aa = THE ALLOWABLE AREA IN SQUARE FEET; At = THE TABULAR FACTOR (NS, S1, OR SR13 VALUE, AS APPLICABLE) IN ACCORDANCE WITH TABLE 506.2; NS = THE TABULAR ALLOWABLE AREA FACTOR IN ACCORDANCE WITH TABLE 506.2 FOR A NON-SPRINKLERED BUILDING (REGARDLESS OF WHETHER THE BUILDING HAS A SPRINKLER SYSTEM); AND If = THE AREA FACTOR INCREASE DUE TO FRONTAGE. THIS BUILDING IS TO HAVE AT LEAST TWO ADJACENT SIDES FACING A YARD OR

PUBLIC WAY OF AT LEAST TWENTY FEET (20') IN WIDTH, WHICH WILL ALLOW FOR A TOTAL BUILDIGN AREA OF 10,503 SQUARE FEET.

N .T

.S

N .T

.S

/7

/2

D at e

CFM PER EQUATION 4-1 AND TABLE 403.3.1.1 OF THE

ADULT

THE THREE YEAR SOLAR REFLECTANCE INDEX OF THE WHITE MEMBRANE ROOF IS 85.

D

AT

E:

SC

AL

E:

SEE NOTE BELOW AT LEFT!

D

ES

C R

IP

TI

O o.

BY

LA

W

TO

N

, O

KL

AH

O

M A

IH

S

LA

W

TO

N V

S/ N

: 2

L

EG

AC

Y

D R

. S

TE

. B 3-

PW

PL

AN

O , T

X.

D R

AW

N

B Y:

STEEL DOOR = 0.20

DUAL PANE/ LOW-E GLASS = 0.51

DUAL PANE/ LOW-E GLASS = 0.25

TE

L.

(4

) 8

-5

R-VALUES PROVIDED ARE AS REQUIRED TO PASS COMCHECK COMPLIANCE SOFTWARE FOR THE:

ALUMINUM

YU

R

IA

N

TO

Y

U R

IA

N

TO

, P

.E

M O

D U

LA

R

S

TR

U C

TU

R

AL

C

O N

SU

LT

AN

TS

L

LC

IHS COVID CLINIC

S/N: 2655 A-1

SHEET No.

C H

EC

K

BY

MEMBRANE

PL

O

T

SC

AL

E:

C O

VE

R

S H

EE

T

/ S

PE

C

IF

IC

AT

IO

N

S

IH

S

C O

VI

D

C

LI

N

IC

N O

R T

H I-

E

D E

SO

T

O , T

X

Ph : 4

-7

-0

, A

LL

R

IG

H

TS

R

ES

ER

VE

P A

L O

M A

R M

O D

U L

A R

B U

IL

D

IN

G

S L

L C

SCALE: 3/32" = 1'-0"

FLOOR FRAMING LAYOUT1

\\palomar-main\Company\CAD_Shares\PALOMAR\Drawings\0000 - IHS LAWTON\64147 IHS LAWTON V2.dwg, 1/8/2024 10:10:37 AM, Microsoft Print to PDF

L O

M A

R M

O D

U L

A R

B U

IL

D

IN

G

S L

L C

SCALE: 3/32" = 1'-0"

ROOF DRAINAGE LAYOUT1

\\palomar-main\Company\CAD_Shares\PALOMAR\Drawings\0000 - IHS LAWTON\64147 IHS LAWTON V2.dwg, 1/8/2024 10:11:02 AM, Microsoft Print to PDF

C-6/8

E- 2/

A- 6/

R

TU

-1

B- 4/

R

TU

-2

C -3

/5 R

TU

-3

C -2

/4

R

TU

-4

D -2

/4

R

TU

-5

E- 1/

R

TU

-6

F- 1/

R

TU

-7

A- 4 A-

B-

C -1

D -1

E-

F-5 F-

F-

B-8/10 B-2 B-11

E-

A-

B-12

-6

F-

B-

B-

D -1

P A

L O

M A

R M

O D

U L

A R

B U

IL

D

IN

G

S L

L C

POWER DISTRIBUTION SCHEMATIC

SCALE: 3/32" = 1'-0"1

\\palomar-main\Company\CAD_Shares\PALOMAR\Drawings\0000 - IHS LAWTON\64147 IHS LAWTON V2.dwg, 1/8/2024 10:12:43 AM, Microsoft Print to PDF

CONDUCTOR SIZE 100 AMP LOAD CALCULATIONS: 120 / 208v MIN. GROUND SIZE PANEL 'A' MIN. 23 LED 2'x4' Troffer x 125% x 45 1294 watts

WIRE CONDUIT SIZE WIRE 0 Fluoresent T-8's 3-Lamp x 125% x 88 0 watts

SIZE DESCRIPTION Watts Bkr. # Leg 'A' Leg 'B' Leg 'C' # Bkr. Watts DESCRIPTION SIZE 1 Ext. LED Porch Light x 125% x 22 28 watts

12 LIGHTING: OPEN OFFICE 832 20 1 832 2 0 Ext. LED Wall Pack Light x 125% x 58 0 watts

3 1440 4 20 1440 RECEPTS: SUPPLY & LOUNGE 12 0 Exhaust Fan & LED Light x 125% x 36 0 watts

12 RECEPTS: CONF. ROOM 1440 20 5 5940 6 60 4500 HVAC: RTU1 BY OTHERS 6 0 Exhaust Fan 260 cfm x 125% x 166 0 watts

7 4500 8 2P 4500 24 Recept Duplex x 180 4320 watts

12 RECEPTS: OPEN OFFICE & CONF. 1440 20 9 1946 10 20 506 LIGHTING: SUPPLY & LOUNGE 12 0 Quad Receptacle x 360 0 watts

11 0 12 0 Water Heater (240v) x 125% x 4500 0 watts

13 0 14 0 Water Cooler x 370 0 watts

15 0 16 0 Res. Microwave (1100 watt) x 1100 0 watts

17 0 18 0 Res. Refrigerator x 840 0 watts

19 0 20 1 Emergency Light x 14.4 14.4 watts

21 0 22 1 Exit Sign x 2.8 2.8 watts

23 0 24 1 Goodman AHU ASPT 2 TON / 8kw (240v) x 9000 9000

25 0 26 0 0 Bard 2.5Ton / 10kw (240v) x 12064 0 watts

0 27 0 28 0

0 29 0 30 0 TOTAL watts

TOTAL Watts Leg 'A' 5332

TOTAL Watts Leg 'B' 3386 TOTAL AMP DRAW= 40.69 amps

TOTAL Watts Leg 'C' 5940 14658

CONDUCTOR SIZE 100 AMP LOAD CALCULATIONS: 120 / 208v MIN. GROUND SIZE PANEL 'B' MIN. 8 LED 2'x4' Troffer x 125% x 45 450 watts

WIRE CONDUIT SIZE WIRE Fluoresent T-8's 3-Lamp x 125% x 88 0 watts

SIZE DESCRIPTION Watts Bkr. # Leg 'A' Leg 'B' Leg 'C' # Bkr. Watts DESCRIPTION SIZE 2 Ext. LED Wall Pack Light x 125% x 58 145 watts

12 LIGHTING: STAFF RR,SPR,UTIL 805 20 1 2005 2 20 1200 WASHER 12 Ext. LED Wall Pack Light x 125% x 58 0 watts

3 4500 4 60 4500 HVAC: RTU2 BY OTHERS 6 0 Exhaust Fan 210 cfm x 125% x 127 0 watts

5 4500 6 2P 4500 2 Exhaust Fan 80 cfm x 125% x 84 210 watts

12 RECEPTS: OPEN OFC, CONF. 1440 20 7 4240 8 25 2800 CLOTHES DRYER 10 1 Dedicated Receptacle x 1920 1920 watts

9 2800 10 2P 2800 240 V 18 Recept Duplex x 180 3240 watts

12 DED RECEPT: RECIRC PUMP 1920 20 11 2460 12 20 540 RECEPTS: HOUSEKEEP 1 12 0 Water Heater (240v) x 125% x 4500 0 watts

12 FLOOR RECEPTS: CONFERENCE 540 20 13 1260 14 20 720 FLOOR RECEPTS: CONFERENCE 12 1 Clothes Washer (120v) x 1200 1200 watts

15 0 16 1 Clothes Dryer (240v) x 5600 5600 watts

17 0 18 0 Res. Refrigerator x 840 0 watts

19 0 20 Emergency Light x 14.4 0 watts

21 0 22 Exit Sign x 2.8 0 watts

23 0 24 Goodman AHU ASPT 2 TON / 8kw (240v) x 9000 9000

25 0 26 Bard 2.5Ton / 10kw (240v) x 12064 0 watts

27 0 28 0

29 0 30 0 TOTAL watts

TOTAL Watts Leg 'A' 7505

TOTAL Watts Leg 'B' 7300 TOTAL AMP DRAW= 60.41 amps

TOTAL Watts Leg 'C' 6960 21765

CONDUCTOR SIZE 3 100 AMP LOAD CALCULATIONS: 120 / 208v MIN. GROUND SIZE PANEL 'C' MIN. 24 Fluoresent T-8's 3-Lamp x 125% x 88 2640 watts

WIRE CONDUIT SIZE 1 1/2 WIRE Fluoresent T-8's 3-Lamp x 125% x 88 0 watts

SIZE DESCRIPTION Watts Bkr. # Leg 'A' Leg 'B' Leg 'C' # Bkr. Watts DESCRIPTION SIZE Ext. LED Porch Light x 125% x 22 0 watts

1 4500 2 60 4500 HVAC: RTU4 BY OTHERS 6 Ext. LED Wall Pack Light x 125% x 58 0 watts

6 HVAC: RTU3 BY OTHERS 4500 60 3 9000 4 2P 4500 Exhaust Fan & LED Light x 125% x 36 0 watts

4500 2P 5 6750 6 25 2250 WATER HEATER 10 Exhaust Fan 260 cfm x 125% x 166 0 watts

7 2250 8 2P 2250 50 GAL 5 Recept Duplex x 180 900 watts

9 0 10 Dedicated Quad Receptacle x 1920 0 watts

12 LIGHTS: CONFERENCE 2654 20 11 3554 12 20 900 RECEPTS:OPEN OFC,CONF,MECH 12 1 Water Heater (240v) x 125% x 4500 4500 watts

13 0 14 Water Cooler x 370 0 watts

15 0 16 0 Clothes Washer (120v) x 1200 0 watts

17 0 18 Res. Refrigerator x 840 0 watts

19 0 20 1 Emergency Light x 14.4 14.4 watts

21 0 22 Alarm Panel - FireLite x 144 0 watts

23 0 24 2 Goodman AHU ASPT 2 TON / 8kw (240v) x 9000 18000

25 0 26 0 Bard 2.5Ton / 10kw (240v) x 12064 0 watts

0 27 0 28 0

0 29 0 30 0 TOTAL watts

TOTAL Watts Leg 'A' 6750

TOTAL Watts Leg 'B' 9000 TOTAL AMP DRAW= 72.32 amps

TOTAL Watts Leg 'C' 10304 26054

CONDUCTOR SIZE 100 AMP LOAD CALCULATIONS: 120 / 208v MIN. GROUND SIZE PANEL 'D' MIN. 18 LED 2'x4' Troffer x 125% x 45 1013 watts

WIRE CONDUIT SIZE WIRE Fluoresent T-8's 3-Lamp x 125% x 88 0 watts

SIZE DESCRIPTION Watts Bkr. # Leg 'A' Leg 'B' Leg 'C' # Bkr. Watts DESCRIPTION SIZE 1 Ext. LED Porch Light x 125% x 22 28 watts

1 4500 2 60 4500 HVAC: RTU5 BY OTHERS 6 Ext. LED Wall Pack Light x 125% x 58 0 watts

3 4500 4 2P 4500 0 Exhaust Fan 210 cfm x 125% x 127 0 watts

12 LIGHTS: HALL, ENTRY 1061 20 5 1781 6 20 720 RECEPTS: WAITING, HALL WOMENS 12 0 Exhaust Fan 80 cfm x 125% x 84 0 watts

7 0 8 11 Recept Duplex x 180 1980 watts

9 0 10 0 Duplex Receptacle x 180 0 watts

12 RECEPTS: IT, WAITING, HALL 1260 20 11 1404 12 20 144 ALARM PANEL 12 Water Heater (240v) x 125% x 4500 0 watts

13 0 14 Water Cooler x 370 0 watts

15 0 16 Res. Microwave (1100 watt) x 1100 0 watts

17 0 18 1 Alarm Panel - FireLite x 144 144 watts

19 0 20 1 Emergency Light x 14.4 14.4 watts

21 0 22 2 Exit Sign x 2.8 5.6 watts

23 0 24 1 Goodman AHU ASPT 2 TON / 8kw (240v) x 9000 9000

0 25 0 26 Bard 2.5Ton / 10kw (240v) x 12064 0 watts

0 27 0 28

0 29 0 30 0 TOTAL watts

TOTAL Watts Leg 'A' 4500

TOTAL Watts Leg 'B' 4500 TOTAL AMP DRAW= 33.82 amps

TOTAL Watts Leg 'C' 3185 12185

# REVISION PROJECT:

6 REVISED PER CUST. REVIEW

DRAWING No.

3-PHASE

MLO

SHEET

E-3

DATE:

1 1/2

14658

Total Watts

21765

Total Watts

Total Watts

12184

3-PHASE

MLO

1 1/2

1/8/2024

3-PHASE

MLO

3-PHASE

MLO

Total Watts

COPYRIGHT 2020 PALOMAR MODULAR BUILDINGS LLC INC. ALL RIGHTS RESERVED

1 1/2

BY: DATE: CALCS BY:

PALOMAR MODULAR BUILDINGS LLC

CHECKED BY:

RM 1/8

26054

CONDUCTOR SIZE ERROR AMP LOAD CALCULATIONS: 120 / 208v MIN. GROUND SIZE PANEL 'E' MIN. 27 LED 2'x4' Troffer x 125% x 45 1519 watts

WIRE CONDUIT SIZE WIRE Fluoresent T-8's 3-Lamp x 125% x 88 0 watts

SIZE DESCRIPTION Watts Bkr. # Leg 'A' Leg 'B' Leg 'C' # Bkr. Watts DESCRIPTION SIZE 1 Ext. LED Porch Light x 125% x 22 28 watts

6 HVAC: RTU6 BY OTHERS 4500 60 1 6750 2 25 2250 WATER HEATER 10 2 Ext. LED Wall Pack Light x 125% x 58 145 watts

4500 2P 3 6750 4 2P 2250 50 GAL Exhaust Fan & LED Light x 125% x 36 0 watts

12 RECEPTS: EXAM 1&2,WAIT, MENS 1440 20 5 2467 6 20 1027 LIGHTS: WAIT,IT,ED 1&2, SUPER 12 2 Exhaust Fan 210 cfm x 125% x 127 318 watts

7 0 8 8 Recept Duplex x 180 1440 watts

9 0 10 1 Dedicated Receptacle x 1920 1920 watts

12 LIGHTS: RR'S,SPPLY 3&4,HKEEP2 1129 20 11 3049 12 20 1920 DED. RECEPT: RECIRC PUMP 12 1 Water Heater (240v) x 125% x 4500 4500 watts

13 0 14 Water Cooler x 370 0 watts

15 0 16 Res. Microwave (1100 watt) x 1100 0 watts

17 0 18 Res. Refrigerator x 840 0 watts

19 0 20 2 Emergency Light x 14.4 28.8 watts

21 0 22 2 Exit Sign x 2.8 5.6 watts

23 0 24 0 1 Goodman AHU ASPT 2 TON / 8kw (240v) x 9000 9000

0 25 0 26 0 Bard 2.5Ton / 10kw (240v) x 12064 0 watts

0 27 0 28 0

0 29 0 30 0 TOTAL watts

TOTAL Watts Leg 'A' 6750

TOTAL Watts Leg 'B' 6750 TOTAL AMP DRAW= 52.47 amps

TOTAL Watts Leg 'C' 5516 19016

CONDUCTOR SIZE ERROR AMP LOAD CALCULATIONS: 120 / 208v MIN. GROUND SIZE PANEL 'F' MIN. 10 LED 2'x4' Troffer x 125% x 45 563 watts

WIRE CONDUIT SIZE WIRE Fluoresent T-8's 3-Lamp x 125% x 88 0 watts

SIZE DESCRIPTION Watts Bkr. # Leg 'A' Leg 'B' Leg 'C' # Bkr. Watts DESCRIPTION SIZE 0 Ext. LED Porch Light x 125% x 22 0 watts

6 HVAC: RTU7 BY OTHERS 4500 60 1 4500 2 2 Ext. LED Wall Pack Light x 125% x 58 145 watts

4500 2P 3 5220 4 20 720 RECEPTS: EX RM 5,6,7 12 Exhaust Fan & LED Light x 125% x 36 0 watts

12 RECEPTS: EX RM 2,SUPR,WAIT,HALL 1260 20 5 2700 6 20 1440 RECEPTS: EX RM 3,4,5 SUPR 12 0 Exhaust Fan 210 cfm x 125% x 127 0 watts

0 7 0 8 0 Dedicated Receptacle x 1920 0 watts

0 9 0 10 23 Recept Duplex x 180 4140 watts

12 LIGHTS: EX RM 3,4,5,6,7 722 20 11 1442 12 20 720 RECEPTS: EX 7,SPLY,HKEEP2 12 Water Heater (240v) x 125% x 4500 0 watts

13 0 14 Water Cooler x 370 0 watts

15 0 16 Res. Microwave (1100 watt) x 1100 0 watts

17 0 18 Res. Refrigerator x 840 0 watts

19 0 20 0 1 Emergency Light x 14.4 14.4 watts

21 0 22 0 0 Exit Sign x 2.8 0 watts

23 0 24 0 1 Goodman AHU ASPT 2 TON / 8kw (240v) x 9000 9000

25 0 26 0 Bard 2.5Ton / 10kw (240v) x 12064 0 watts

27 0 28 0

0 29 0 30 0 TOTAL watts

TOTAL Watts Leg 'A' 4500

TOTAL Watts Leg 'B' 5220 TOTAL AMP DRAW= 38.48 amps

TOTAL Watts Leg 'C' 4142 13862

TOTAL Watts Leg 'A' 35337 SERVICE ENTRANCE AMPS

TOTAL Watts Leg 'B' 36156 CONDUCTOR SIZE AWG

TOTAL Watts Leg 'C' 36047 GROUND SIZE AWG

CONDUIT SIZE INCH

# REVISION PROJECT:

DRAWING No.

COPYRIGHT 2020 PALOMAR MODULAR BUILDINGS LLC INC. ALL RIGHTS RESERVED

PALOMAR MODULAR BUILDINGS LLC

DATE:

1/8/2024

SHEET

E-3.1

CALCS BY:

SGD

DATE:

TOTAL AMPS

CHECKED BY:

298.50

BY:

BUILDING TOTAL LOADS

2100.06

100.36

TOTAL WATTS 107540

#N/A

#N/A

30098.09

TOTAL AMPS

Total Watts

#N/A

3-PHASE

#N/A MLO

18903

#N/A

#N/A 3-PHASE

MLO

13862

Total Watts

L O

M A

R M

O D

U L

A R

B U

IL

D

IN

G

S L

L C

ALARM SYSTEM LAYOUT

SCALE: 3/32" = 1'-0"1

\\palomar-main\Company\CAD_Shares\PALOMAR\Drawings\0000 - IHS LAWTON\64147 IHS LAWTON V2.dwg, 1/8/2024 10:20:18 AM, Microsoft Print to PDF

A1.pdf
A2.pdf
A3.pdf
A4.pdf
A5.pdf
S1.pdf
S2.pdf
S3.pdf
S4.pdf
S4.1.pdf
S5.pdf
S6.pdf
M1.pdf
M2.pdf
M3.pdf
E1.pdf
E2.pdf
E3.pdf
E4.pdf

File details come from the government source that posted it. Updated .