Smith River Border Station - HVAC Split System Working Drawings

This is a set of working drawings prepared by GHD Inc. for the State of California Department of General Services (DGS), Division of the State Architect (DSA), for the Smith River Border Station HVAC Split System project located at 17200 US 101, Smith River, California 95567. The project involves the installation of a ductless split HVAC system to replace existing furnace and associated equipment. The scope includes demolition of existing furnace, return and supply registers, and flex ductwork; installation of four ductless fan coil units (FC-101, FC-102, FC-103, and FC-201) with associated refrigerant piping and condensate drain systems; installation of supply fan filter boxes with MERV-13 filters; and installation of new electrical distribution panel and disconnect switches. The project includes modifications to both the floor level and a 438-square-foot mezzanine area. DGS Project Number 13984 references work order M29562 with an expiration date of June 30, 2027. Project Manager Anthony Brown and mechanical engineer Terry Wong are identified as responsible parties. The drawings were prepared as of February 2, 2026, and reviewed by DSA on April 14, 2026.

The working drawings establish detailed design specifications and installation requirements, including thermostat mounting heights of 48 inches above finished floor and ductless fan coil mounting at 80 inches above finished floor to the unit's bottom. Electrical work requires compliance with the latest California Electrical Code and includes a 200-ampere, 240-volt, single-phase meter main panel with branch circuit panel replacement and dedicated disconnect switches for equipment. The documents specify that all existing equipment and piping dimensions and locations must be verified in the field prior to demolition and construction, with all discrepancies reported immediately to the engineer. Refrigerant piping uses 3/8-inch suction lines and 1/4-inch liquid lines, and condensate drains consist of 5/8-inch copper pipe routed to the nearest lavatory fixture or daylighted outdoors six inches above finished grade. The project requires coordination with the owner regarding shutdown of existing systems and adherence to manufacturer's installation instructions for all equipment.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TEST MARK (For DSA Use Only) Prior to adding document to the Session the Plan Reviewer shall place this test mark off the top edge of the first sheet and change status to "INCORPORATE".

If Back-check menu does not show or the color does not change to green, the Plan Reviewer shall fix the back-check menu. For guidance on how to fix the back-check menu, refer to PR 18-06, Appendix D, Checklist D2.

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926

04/14/2026

D E P A R T M E N T O F G E N E R A L S E R V I C E S

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926

M001

MECHANICAL LEGEND,

ABBREVIATIONS AND

GENERAL NOTES

AS NOTED

02-02-2026

13984

CONSULTANT:

117 PARK PLACE

POINT RICHMOND

CALIFORNIA 94801

(510) 236-7435 www.intres.com

IR PROJECT #2017-050-06

STAMP:

ABCDEFGHIJKLMNOPQRSTU

ABCDEFGHIJKLMNOPQRSTU

Issue No.

Date Description

Project

Supervisor Designed Drawn Checked

File Date Vault File Number

Sheet Title

DGS Project # Work Order

Reference North Sheet Scale

Sheet Number

X

Project Manager: Anthony Brown 916 879-1021 Voice

Anthony.brown@ dgs.ca.gov

707 Third Street, 3rd Floor

Design Services Section

Facility Management Division State of California

West Sacramento, California 95605

Department of General Services

GHD Inc.

2235 Mercury Way Suite 150 Santa Rosa California 95407 USA T 1 707 523 1010 W www.ghd.com

SMITH RIVER

BORDER

STATION - HVAC

SPLIT SYSTEM

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

M29562 6/30/27

No.

Exp.

RE

G I

S T

ER

ED PRO F E S S I ON A L ENGI NEER

S TA T E O F C A L I F O R N I A

T E R R Y W O NG

M E C H A N I C A L

GENERAL MECHANICAL NOTESABBREVIATIONS

FD

FSD

M

DUCT SECTION, SUPPLY AIR UP

DUCT SECTION, RETURN AIR UP

DUCT SECTION, EXHAUST AIR UP

DUCT SECTION, SUPPLY AIR DN

DUCT SECTION, RETURN AIR DN

DUCT SECTION, EXHAUST AIR DN

FLEXIBLE DUCT

FIRE AND SMOKE DAMPER

FIRE DAMPER

DIRECTION OF FLOW

MANUAL VOLUME DAMPER

WALL SUPPLY OUTLET, RETURN GRILLE

CEILING DIFFUSER

CEILING RETURN

CEILING EXHAUST

DUCT SMOKE DETECTOR

THERMOSTAT

REMOTE SENSOR

MOTORIZED ACTUATOR

S

AV

FOS

CWS

SYMBOL

FUEL OIL (SUPPLY)

FUEL OIL (RETURN)

CHILLED WATER SUPPLY

CHILLED WATER RETURN

HEATING HOT WATER SUPPLY

HEATING HOT WATER RETURN

CONDENSER WATER SUPPLY

CONDENSER WATER RETURN

REFRIGERANT LIQUID

REFRIGERANT SUCTION

AUTOMATIC AIR VENT

BLOW OFF STRAINER

FILTER AND STRAINER LINE

PRESSURE GAGE

PRESSURE GAGE AND COCK

PRESSURE REDUCING VALVE

RELIEF OR SAFETY VALVE

STRAINER

TEMPERATURE GAGE

PUMP (PLAN)

PUMP (SCHEMATIC)

EXPANSION LOOP

CAP

CONCENTRIC REDUCER

UNION

THREE-WAY MANUAL VALVE

BALL VALVE

BUTTERFLY VALVE

DIAPHRAGM VALVE

GATE VALVE

GLOBE VALVE

CHECK VALVE

POINT OF CONNECTION

FLEXIBLE CONNECTOR

THERMOMETER

PETE'S PLUG

AIR TERMINAL IDENTIFICATION

AIR TERMINAL MARK

AIRFLOW, CFM

NOTE:

ARROWS INDICATE DIRECTION OF AIRFLOW

NO ARROWS INDICATE 4-WAY AIRFLOW

AIR TERMINAL NECK SIZE (IF SHOWN)

KEYNOTE

ROOM NAME AND ROOM NUMBER

DETAIL INDICATOR SECTION INDICATOR

MECHANICAL EQUIPMENT

DESIGNATION

(SEE SCHEDULE)

DETAIL NUMBER

SHEET NUMBER ON WHICH DETAIL

APPEARS

SECTION LETTER

SHEET NUMBER ON WHICH SECTION

APPEARS

SHEET ANNOTATION

CARBON DIOXIDE SENSOR

DESCRIPTION

FOR

CWR

HHWS

HHWR

CS

CR

RL

RS

P

A AMPERES, AREA

ABS ACRYLONITRILE-BUTADIENE

-STYRENE

AD AREA DRAIN

AFF ABOVE FINISHED FLOOR

AG ABOVE GRADE

APPROX APPROXIMATE

AS AIR SEPARATOR

AVG AVERAGE

BD BALANCE DAMPER

BDD BACK DRAFT DAMPER

BFP BACK FLOW PREVENTER

BG BELOW GRADE

BHP BRAKE HORSEPOWER

BOD BOTTOM OF DUCT

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT

PER HOUR

C CELSIUS

℄ CENTERLINE

CCW COUNTER CLOCKWISE

CD CEILING DIFFUSER,

CONDENSATE DRAIN

CFM CUBIC FEET PER MINUTE

CH CHILLER

CHWP CHILLED WATER PUMP

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CI CAST IRON

CMPR COMPRESSOR

CONT CONTINUED

CT COOLING TOWER

CU COPPER

CU FT CUBIC FEET

CU IN CUBIC INCHES

CW COLD WATER, CLOCKWISE

CWP CONDENSER WATER PUMP

CWR CONDENSER WATER RETURN,

CWS CONDENSER WATER SUPPLY

CWV COMBINATION WASTE & VENT

D DEPTH

DB DECIBEL, DRY BULB

DEG DEGREE(S)

DIA DIAMETER

DN DOWN

DPT DIFFERENTIAL PRESSURE

TRANSMITTER

DS DOWN SPOUT

DWG DRAWING

(E) EXISTING

EA EACH

EAT ENTERING AIR TEMPERATURE

EF EXHAUST FAN

EFF EFFICIENCY

EG EXHAUST GRILLE

ELEV ELEVATION

ENT ENTERING

ESP EXTERNAL STATIC PRESSURE

F FLOW

FACP FIRE ALARM CONTROL PANEL

FCO FLOOR CLEAN OUT

FD FLOOR DRAIN, FIRE DAMPER

FDC FIRE DEPARTMENT

CONNECTION

FM FLOW METER

FP FIRE PROTECTION

FPI FINS PER INCH

FPM FEET PER MINUTE

FPS FEET PER SECOND

FS FLOW SWITCH

FSD FIRE/SMOKE DAMPER

FSP FIRE SPRINKLER

FT FOOT, FEET

G GAS

GA GAUGE

GALV GALVANIZED

GPD GALLONS PER DAY

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

GPS GALLONS PER SECOND

HD HEAD

HG MERCURY

HWR HEATING WATER RETURN

HWS HEATING WATER SUPPLY

HP HORSEPOWER

HR HOSE REEL, HOUR

HT HEIGHT

HVAC HEATING, VENTILATION

& CONDITIONING

HW HOT WATER

HWR HOT WATER RETURN

HZ FREQUENCY

ID INSIDE DIAMETER

INVERT INVERT ELEVATION

IW INDIRECT WASTE

KW KILOWATTS

KWH KILOWATTS PER HOUR

L LENGTH

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LF LINEAR FEET

LPG LIQUID PETROLEUM GAS

LTG LIGHTING

LVG LEAVING

LWT LEAVING WATER TEMPERATURE

MAX MAXIMUM

MBH 1,000 BTUH

MCC MOTOR CONTROL CENTER

MD MOTORIZED DAMPER

MFR MANUFACTURER

MIN MINIMUM, MINUTE

MTD MOUNTED

MUA MAKE UP AIR

(N) NEW

NC NORMALLY CLOSED, NOISE CRITERIA

NIC NOT IN CONTRACT

NO NORMALLY OPEN, NUMBER

NTS NOT TO SCALE

OA OUTSIDE AIR

OBD OPPOSED BLADE DAMPER

OC ON CENTER

OD OUTSIDE DIAMETER

ORD OVERFLOW ROOF DRAIN

PB POLYBUTYLENE

PE POLYETHYLENE

PPM PARTS PER MILLION

POC POINT OF CONNECTION

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH,

ABSOLUTE

PSIG POUNDS PER SQUARE INCH, GAGE

PVC POLYVINYL CHLORIDE

RA RETURN AIR

RD ROOF DRAIN

REQ REQUIRED

RG RETURN GRILLE

RH RELATIVE HUMIDITY

RPM REVOLUTIONS PER MINUTE

RPS REVOLUTIONS PER SECOND

SAD SEE ARCHITECTURAL DRAWINGS

STD STANDARD

SOV SHUT OFF VALVE

SD SUPPLY DIFFUSER, STORM DRAIN

SS SANITARY SEWER, STAINLESS STEEL

TD TEMPERATURE DIFFERENTIAL

TEMP TEMPERATURE

TOD TOP OF DUCT

TP TOTAL STATIC PRESSURE

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

V VENT, VOLT

VEL VELOCITY

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

VP VELOCITY PRESSURE

VTR VENT THROUGH ROOF

W WIDTH

W/ WITH

WB WET BULB

WG WATER GAGE

W/O WITHOUT

WRG WALL RETURN GRILLE

WSR WALL SUPPLY REGISTER

WH WATER HEATER

WHA WATER HAMMER ARRESTOR

XFMR TRANSFORMER

YR YEAR

Z ZONE

HVAC PIPING

MECHANICAL SYMBOLS LEGEND

1. THESE DRAWINGS ARE BASED UPON AVAILABLE DOCUMENTS, WHICH MAY NOT ACCURATELY

PORTRAY AS-BUILT CONDITIONS. EXISTING EQUIPMENT AND PIPING SIZES, LOCATIONS, AND

DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO DEMOLITION AND CONSTRUCTION.

NOTIFY THE ENGINEER IMMEDIATELY OF ALL DISCREPANCIES AFFECTING THE REMOVAL OF

EXISTING EQUIPMENT AND PIPING, AND THE INSTALLATION OF NEW EQUIPMENT AND PIPING.

2. INSTALL PIPING AND DUCTWORK TO BEST SUIT FIELD CONDITIONS AND COORDINATE WITH THE

INSTALLATION WORK OF OTHER TRADES. THESE DRAWINGS ARE DIAGRAMMATIC, DO NOT SCALE

TO DETERMINE EXACT LOCATION OF PIPING.

3. PROTECT ALL EXISTING EQUIPMENT THAT IS TO REMAIN. VERIFY WITH OWNER WHAT SYSTEMS

WILL REMAIN OPERATIONAL THROUGHOUT CONSTRUCTION. NOTIFY THE OWNER PRIOR TO

SHUTTING DOWN ANCILLARY SYSTEMS OR EQUIPMENT.

4. REPAIR AND/OR REPLACE ALL EXISTING UTILITIES, STRUCTURAL ELEMENTS, EQUIPMENT, PIPING, CONDUIT, DUCTWORK, ETC. THAT IS DAMAGED OR BECOMES INOPERABLE AS A RESULT OF THIS

WORK.

5. COORDINATE MODIFICATIONS TO EXISTING SYSTEMS WITH OWNER TO MINIMIZE SHUTDOWN TIME

OF BUILDING SYSTEMS.

6. FOR ALL MECHANICAL SYSTEMS CONTROLS, PROVIDE CONDUIT AND WIRING IN ACCORDANCE

WITH DIVISION 26 SPECIFICATIONS AND MANUFACTURER'S REQUIREMENTS.

7. ALL SANITARY AND SANITARY VENT PIPING SHALL SLOPE AT 14" PER 12" UNLESS OTHERWISE

NOTED.

SYMBOLDESCRIPTION

DD

T

CO2

12x12 SD-1

WH

X-501

A X-301

MECH ROOM

RCR RCR DBR

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926 http://www.ghd.com/

FD

A

B

C

D

E

1 2 3 4 5

WOMEN

MEN

INSPECTION

BAYS

STORAGE

GENERATOR

OFFICE

A

B

C

D

E

1 2 3 4 5

438 SF

MEZZANINE

M101

FLOOR AND

MEZZANINE PLANS

SMITH RIVER, CALIFORNIA 95567

AS NOTED

02-02-2026

13984

CONSULTANT:

117 PARK PLACE

POINT RICHMOND

CALIFORNIA 94801

(510) 236-7435 www.intres.com

IR PROJECT #2017-050-06

STAMP:

ABCDEFGHIJKLMNOPQRSTU

ABCDEFGHIJKLMNOPQRSTU

Issue No.

Date Description

Project

Supervisor Designed Drawn Checked

File Date Vault File Number

Sheet Title

DGS Project # Work Order

Reference North Sheet Scale

Sheet Number

X

Project Manager: Anthony Brown 916 879-1021 Voice

Anthony.brown@ dgs.ca.gov

707 Third Street, 3rd Floor

Design Services Section

Facility Management Division State of California

West Sacramento, California 95605

Department of General Services

GHD Inc.

2235 Mercury Way Suite 150 Santa Rosa California 95407 USA T 1 707 523 1010 W www.ghd.com

SMITH RIVER

BORDER

STATION - HVAC

SPLIT SYSTEM

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

M29562 6/30/27

No.

Exp.

RE

G I

S T

ER

ED PRO F E S S I ON A L E NGI NEER

STA T E O F C A L I F O R N I A

T E R R Y W O N G

M E C H A N I C A L

1/4" = 1'-0"2 MEZZANINE PLAN

1/4" = 1'-0"1 FLOOR PLAN

FC

FC

FC

FC

HP

(E) FURNACE

HP

(E) GENERATOR

(E) LPG STORAGE TANKS

TFC-101

TFC-102

TFC-103

T FC-201

(E) SUPPLY REGISTER

TO REMAIN

(E) RETURN REGISTER

(E) 1/2" GAS LINE

L

8"Ø

8" Ø

SHEET GENERAL NOTES

1. MOUNT THERMOSTATS 48" ABOVE FINISHED FLOOR TO TOP OF THERMOSTAT.

2. MOUNT DUCTLESS FAN COILS 80" ABOVE FINISHED FLOOR TO BOTTOM OF UNIT.

SHEET KEYNOTES

1. DEMOLISH EXISTING FURNACE AND ASSOCIATED APPURTENANCES. DISCONNECT GAS

LINE AND CAP. CAP THE BOTTOM OF FLUE, FLUE TO REMAIN ABANDONED IN PLACE.

2. DEMOLISH EXISTING RETURN REGISTER AND PATCH OPENING INTO SPACE. MATCH PAINT

WITH EXISTING.

3. DEMOLISH EXISTING FLEX DUCT AND ASSOCIATED APPURTENANCES.

4. DEMOLISH EXISTING SUPPLY REGISTER AND PATCH OPENING INTO SPACE. MATCH PAINT

WITH EXISTING.

5. PROVIDE FAN FILTER BOX WITH 24" x 12" x 2" MERV-13 FILTER. REFER TO SUPPLY FAN

SCHEDULE ON SHEET M-601 FOR FILTER BOX SIZING. PROVIDE FLEXIBLE CONNECTION

BETWEEN FAN AND DUCTWORK.

6. 12" W x 10" H LOUVER OPENING. PROVIDE STAINLESS STEEL INSECT SCREEN.

7. ROUTE 5/8" CONDENSATE DRAIN TO NEAREST LAVATORY FIXTURE TAILPIECE. PROVIDE

LAVATORY TAILPIECE W/ CONDENSATE DRAIN CONNECTION.

8. DAYLIGHT 5/8" DWV COPPER CONDENSATE DRAIN OUTDOORS, TERMINATE 6" ABOVE

FINISHED GRADE.

(E) 6"Ø FLEX DUCT

SF

REUSE EXISTING FLEX DUCT

(E) 1/2" GAS LINE

(E) 1/2" GAS LINE

(E) 1/2" GAS LINE

CONTINUED ON 2, M101

(E) SUPPLY REGISTER

TO REMAIN

(E) SUPPLY REGISTER

TO REMAIN

RCR RCR DBR

5/8" CONDENSATE DRAIN

3/8" SUCTION

1/4" LIQUID

3/8" SUCTION

1/4" LIQUID

3/8" SUCTION

1/4" LIQUID

3/8" SUCTION

1/4" LIQUID

5/8" CONDENSATE DRAIN

3/8" SUCTION

1/4" LIQUID TO FC-103

3/8" SUCTION

1/4" LIQUID TO FC-101 & FC-102

3/8" SUCTION

1/4" LIQUID TO FC-201

5/8" CONDENSATE DRAIN FROM HP-1

5/8" CONDENSATE DRAIN FROM HP-2 8

5/8" CONDENSATE DRAIN.

ROUTE THROUGH ATTIC

SPACE

5/8" CONDENSATE DRAIN.

ROUTE THROUGH ATTIC

SPACE

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926

ALIGN VERTICAL LEGS OF WALL

BRACKETS W/ (E) STUDS

(N) x4 BLOCKING BETWEEN (E) STUDS

(E) STUDS @ 16" OC. VERIFY IN FIELD

(5 MIN) 3" LAG SCREWS, 1/4" DIA MIN, UPSIZE AS

NEEDED TO FIT EQUIPMENT MOUNTING HOLES

(3) 3" LAG SCREWS PER LEG, 1/4"

DIA MIN, UPSIZE AS NEEDED TO

FIT EQUIPMENT MOUNTING HOLES

EMBED

SCREWS PER PROFILE

(E) STUD WALL

BLOCKING PER PROFILE

PROFILE ELEVATION

MIN 3"

MAX 30"

MIN 10.5"

MAX 16"

M601

MECHANICAL DETAILS

AND SCHEDULES

RCR RCR DBR

AS NOTED

02-02-2026

13984

CONSULTANT:

117 PARK PLACE

POINT RICHMOND

CALIFORNIA 94801

(510) 236-7435 www.intres.com

IR PROJECT #2017-050-06

STAMP:

ABCDEFGHIJKLMNOPQRSTU

ABCDEFGHIJKLMNOPQRSTU

Issue No.

Date Description

Project

Supervisor Designed Drawn Checked

File Date Vault File Number

Sheet Title

DGS Project # Work Order

Reference North Sheet Scale

Sheet Number

X

Project Manager: Anthony Brown 916 879-1021 Voice

Anthony.brown@ dgs.ca.gov

707 Third Street, 3rd Floor

Design Services Section

Facility Management Division State of California

West Sacramento, California 95605

Department of General Services

GHD Inc.

2235 Mercury Way Suite 150 Santa Rosa California 95407 USA T 1 707 523 1010 W www.ghd.com

SMITH RIVER

BORDER

STATION - HVAC

SPLIT SYSTEM

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

M29562 6/30/27

No.

Exp.

RE

G I

S T

ER

ED PRO F E S S I ON A L E NGI NEER

STA T E O F C A L I F O R N I A

T E R R Y W O N G

M E C H A N I C A L

1 WALL BRACKET ANCHORAGE

NTS

HANGER BRACKET

3/8"Ø ASTM A36 GALVANIZED

THREADED ROD W/ NUT AND

WASHER AT EACH SIDE OF

ATTACHMENT TO EQUIPMENT

AND ATTACHMENT TO UNISTRUT,

TYP.

DUCT

MECHANICAL

EQUIPMENT AS

SHOWN ON PLANS

3" x 3" x 12" W/(1) 1/2" DIA THRU BOLT OR 12" DIA x

3-1/2" LAG BOLT, TYP.

" M

AX

2 SUSPENDED FAN DETAIL

NTS

FINISHED WALL

WALL MOUNTED DUCTLESS

AIR HANDLING UNIT AND

INSTALLATION PLATE

#10 SCREWS

(TYP. 2) AT EACH

WALL STUD

BLOCKING AS REQUIRED

WITH #10 SCREWS (TYP. 2)

AT EACH WALL STUD.

WALL STUD.

3 DUCTLESS FAN COIL MOUNTING

NTS

NOTE: REFER TO MANUFACTURERS INSTRUCTIONS FOR

INSTALLATION. MOUNT UNIT 80" ABOVE FINISHED FLOOR TO

BOTTOM OF UNIT.

A35, FRAMING CLIP W/#8 FHWS AT

EACH SIDE, TOP & BOTTOM, TYP.

NOTE: REFER TO MFR INSTRUCTIONS FOR MOUNTING

CONDENSING UNIT TO BRACKET.

2" P-TRAP

GROUND JOINT CONNECTION

5/8" CONDENSATE

DRAIN CONNECTION

FINISHED WALL

2" FEMALE NPT OUTLET

WALL ESCUTEON

4 TAILPIECE CONDENSATE DRAIN CONNECTION DETAIL

NOT TO SCALE

BACK-UP

MATERIAL

WATERPROOF

SEALANT

WALL

PIPE SLEEVE

PIPE

INSULATION WHERE REQUIRED

ESCUTCHEON PLATE

(WHERE EXPOSED)ANCHOR

EXTERIOR INTERIOR

5 PIPE THRU EXTERIOR WALL DETAIL

NOT TO SCALE

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926

M701

MECHANICAL

TITLE 24

AS NOTED

02-02-2026

13984

CONSULTANT:

117 PARK PLACE

POINT RICHMOND

CALIFORNIA 94801

(510) 236-7435 www.intres.com

IR PROJECT #2017-050-06

STAMP:

ABCDEFGHIJKLMNOPQRSTU

ABCDEFGHIJKLMNOPQRSTU

Issue No.

Date Description

Project

Supervisor Designed Drawn Checked

File Date Vault File Number

Sheet Title

DGS Project # Work Order

Reference North Sheet Scale

Sheet Number

X

Project Manager: Anthony Brown 916 879-1021 Voice

Anthony.brown@ dgs.ca.gov

707 Third Street, 3rd Floor

Design Services Section

Facility Management Division State of California

West Sacramento, California 95605

Department of General Services

GHD Inc.

2235 Mercury Way Suite 150 Santa Rosa California 95407 USA T 1 707 523 1010 W www.ghd.com

SMITH RIVER

BORDER

STATION - HVAC

SPLIT SYSTEM

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

M29562 6/30/27

No.

Exp.

RE

G I

S T

ER

ED PRO F E S S I ON A L ENGI NEER

STA T E O F C A L I F O R N I A

T E R R Y W O NG

M E C H A N I C A L

RCR RCR DBR

DSA

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926

EDGE OF ELECTRICAL BOX BOLT

HOLES TO ALIGN WITH STUDS

PROFILE ELEVATION

EMBED

(4) 3" LAG SCREWS, 1/4" Ø MIN,

UPSIZE AS NEEDED TO FIT

EQUIPMENT MOUNTING HOLES

1'-3"2 1/2"2" 4'-

4" 2"

2 1/2"

SCREWS PER PROFILE

(E) STUD @ 16" OC,

VERIFY IN FIELD

(E) STUD WALL

EMBED

(2) 3" LAG SCREWS, 1/4" Ø MIN,

UPSIZE AS NEEDED TO FIT

EQUIPMENT MOUNTING HOLES

EDGE OF DISCONNECT BOX

(N) x4 BLOCKING

BETWEEN (E) STUDS

(E) STUD @ 16" OC,

VERIFY IN FIELD

SCREWS PER PROFILE

(E) STUD WALL

PROFILE ELEVATION

6"2"

1 3 /4" 2"

BLOCKING PER PROFILE

E001

ELECTRICAL LEGEND,

ABBREVIATIONS AND

GENERAL NOTES

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

RK RK EAO

AS NOTED

02-02-2026

13984

CONSULTANT:

117 PARK PLACE

POINT RICHMOND

CALIFORNIA 94801

(510) 236-7435 www.intres.com

IR PROJECT #2017-050-06

STAMP:

ABCDEFGHIJKLMNOPQRSTU

ABCDEFGHIJKLMNOPQRSTU

Issue No.

Date Description

Project

Supervisor Designed Drawn Checked

File Date Vault File Number

Sheet Title

DGS Project # Work Order

Reference North Sheet Scale

Sheet Number

X

Project Manager: Anthony Brown 916 879-1021 Voice

Anthony.brown@ dgs.ca.gov

707 Third Street, 3rd Floor

Design Services Section

Facility Management Division State of California

West Sacramento, California 95605

Department of General Services

GHD Inc.

2235 Mercury Way Suite 150 Santa Rosa California 95407 USA T 1 707 523 1010 W www.ghd.com

SMITH RIVER

BORDER

STATION - HVAC

SPLIT SYSTEM

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

ANNOTATION

CONDUIT

MAIN SWITCHBOARD

DISTRIBUTION PANEL BOARD

COMBINATION METER/MAIN SERVICE PANEL

BRANCH CIRCUIT PANEL BOARD, SURFACE OR FLUSH MOUNTED

LIGHTING CONTROL PANEL

SIGNAL TERMINAL CABINET OR CONTROL PANEL

SURFACE OR FLUSH MOUNTED

SIGNAL TERMINAL BACKBOARD

CONCRETE UNDERGROUND HAND HOLE

(NUMBER DENOTES CHRISTY SIZE)

TRANSFORMER

EQUIPMENT

OR

OR

N30

OR

OR

DENOTES HEIGHT IN INCHES

AFF (INTERIOR) AFG (EXTERIOR)

GENERAL ELECTRICAL NOTESELECTRICAL SYMBOLS LEGEND

KEYNOTE

RACEWAY, FEEDER OR CIRCUIT DESIGNATION (SEE SCHEDULE)

LIGHTING FIXTURE TYPE DESIGNATION

(SEE SCHEDULE)

DETAIL INDICATOR SECTION INDICATOR

MECHANICAL EQUIPMENT DESIGNATION

(SEE SCHEDULE)

DUPLEX RECEPTACLE, 20A 125V 2P 3W, GROUNDING TYPE,

MOUNTING HEIGHT: +18" AFF UON

DUPLEX RECEPTACLE - EMERGENCY POWER

SPECIAL PURPOSE RECEPTACLE AS DESIGNATED

SEE 'SPECIAL SYMBOLS' ON EACH SHEET

JUNCTION BOX, CODE SIZED UON

DISCONNECT SWITCH - FUSED WHERE APPLICABLE

MOTOR STARTER, COMBINATION WITH DISCONNECT SWITCH

MOTOR STARTER OR CONTROLLER

MOTOR CONNECTION

POWER POLE: P=POWER, T=TELEPHONE, D=DATA, C=COMBINATION

GROUND ROD

GUY WIRE AND ANCHOR

CONDUIT INSTALLED ABOVE GRADE

CONDUIT INSTALLED UNDERGROUND OR UNDER SLAB

CONDUIT STUB-OUT WITH CAP

FLEXIBLE CONDUIT WHIP TO LIGHT FIXTURE OR EQUIPMENT

DENOTES TYPE

DENOTES WATTS

POWER

#10

CONDUIT HOME RUN TO DESIGNATED PANEL, TERMINAL, OR CONTROL CABINET

EXAMPLES:

NOTE FOR CONDUIT: THE TIC MARKS INDICATE THE QUANTITY OF #12 AWG WIRES

OR, IF INDICATED, THE QUANTITY OF OTHER SIZE WIRE OR CABLES.

SEE THE SINGLE LINE DIAGRAM FOR FEEDER SIZES.

EXAMPLES: = (3) #12 = (2) #10

L1-4

INDICATES

BRANCH PANEL

INDICATES CIRCUIT

BREAKER I.D.

COMMA INDICATES MULTIPLE

SINGLE POLE CIRCUITS

L1-6,8 L1-10/12

SLASH INDICATES

MULTI-POLE CIRCUIT

= (1) TYPE F1 CABLE. SEE CABLE SCHEDULE.

DETAIL NUMBER

SHEET NUMBER ON

WHICH DETAIL APPEARS

SECTION LETTER

SHEET NUMBER ON WHICH

SECTION APPEARS

OR

OR

OBJECT LINES

NEW OBJECTS

(HEAVY CONTINUOUS LINES, UNDERGROUND CONDUIT

HEAVY DASHED LINES)

EXISTING OBJECTS TO REMAIN. MAY INCLUDE NEW CIRCUITING ETC.

(FINE CONTINUOUS LINES, UNDERGROUND CONDUIT

FINE DASHED LINES)

EXISTING OBJECTS TO BE DEMOLISHED

(EXTRA FINE DASHED LINES, SCREENED)

ABBREVIATIONS

(D) DEMOLISH

(E) EXISTING

(F) FUTURE

(N) NEW

A AMPERES

AC ALTERNATING CURRENT

AF AMP FRAME

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AIC AMPS INTERRUPTING CAPACITY

ATS AUTOMATIC TRANSFER SWITCH

AWG AMERICAN WIRE GAUGE

BAT BATTERY

BFG BELOW FINISH GRADE

CATV CABLE TELEVISION

C CONDUIT

CB CIRCUIT BREAKER

CCTV CLOSED CIRCUIT TELEVISION

CO CONDUIT ONLY

CPT CONTROL POWER TRANSFORMER

CT CURRENT TRANSFORMER

CU COPPER

DC DIRECT CURRENT

EF EXHAUST FAN

EGU ENGINE GENERATOR UNIT

EM EMERGENCY

EMT ELECTRICAL METALLIC TUBING

ENT ELECTRICAL NON-METALLIC TUBING

EP EXPLOSION PROOF

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FC FOOT CANDLE

FU FUSE

GND GROUND

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GFI GROUND FAULT INTERRUPTER

GFR GROUND FAULT RELAY

HID HIGH INTENSITY DISCHARGE

HOA "HAND-OFF-AUTO" SWITCH

HP HORSEPOWER

HPS HIGH PRESSURE SODIUM

HVAC HEATING, VENTILATION &

AIR-CONDITIONING

IG ISOLATED GROUND

JB JUNCTION BOX

KAIC KILO-AMPS INTERRUPTING CAPACITY

KV KILOVOLT

KVA KILOVOLT-AMP

KW KILOWATT

KWH KILOWATT-HOUR

LPG LIQUID PROPANE GAS

LPS LOW PRESSURE SODIUM

LV LOW VOLTAGE

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MCP MOTOR CIRCUIT PROTECTOR

MFR MANUFACTURER

MH METAL HALIDE

MLO MAIN LUGS ONLY

MV MEDIUM VOLTAGE

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NTS NOT TO SCALE

PA PUBLIC ADDRESS

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE

PB PULL BOX, ELECTRICAL

RECPT RECEPTACLE, OUTLET

RGS RIGID GALVANIZED STEEL (CONDUIT)

RVSS REDUCED VOLTAGE SOFT START

RTU REMOTE TERMINAL UNIT

TV TELEVISION MONITOR (SET)

TVSS TRANS. VOLT. SURGE SUPPRESSOR

UF UNDER FLOOR

UG UNDERGROUND

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

V VOLT

VA VOLT-AMP

VFD VARIABLE FREQUENCY DRIVE

WP WEATHERPROOF

WPI WEATHERPROOF IN USE

XFMR TRANSFORMER

1. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED VERSION OF THE CALIFORNIA

ELECTRICAL CODE (CEC).

2. THE CONTRACTOR SHALL MAINTAIN ALL EQUIPMENT IN A SAFE AND RESPONSIBLE MANNER.

KEEP DEAD FRONT EQUIPMENT IN PLACE WHILE EQUIPMENT IS ENERGIZED. CONDUCT ALL

CONSTRUCTION OPERATIONS IN A SAFE MANNER FOR EMPLOYEES AS WELL AS OTHER WORK

PERSONS OR ANYONE VISITING THE JOB SITE. PROVIDE BARRIERS, FLAGS, TAPE, ETC. AS

REQUIRED TO MAINTAIN SAFETY.

3. PRIOR TO COMMENCING WORK ON EXISTING SYSTEMS OR WHERE EXISTING SYSTEMS REQUIRE

TEMPORARY SHUT DOWNS, COORDINATE WITH OWNERS REPRESENTATIVE. WHERE

DISCONNECTING, MODIFYING OR WORKING ON EXISTING EQUIPMENT OR SYSTEMS, PROVIDE A

WRITTEN METHOD OF PROCEDURE OUTLINING DATES, TIMES, DURATION AND DESCRIPTION OF

PROPOSED WORK FOR APPROVAL PRIOR TO COMMENCING WORK . WORK ON EXISTING

EQUIPMENT SHALL NOT COMMENCE UNTIL WRITTEN AUTHORIZATION IS GIVEN BY THE OWNERS

REPRESENTATIVE.

4. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING

LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURERS

INSTRUCTIONS.

5. ALL EQUIPMENT SHALL BE GROUNDED PER THE REQUIREMENTS OF CEC ARTICLE 250.

EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN ALL POWER SYSTEM

RACEWAYS.

6. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL DIMENSIONS PRIOR TO

CONSTRUCTION.

7. ALL WORK ON OR AROUND UTILITY EQUIPMENT AND FEEDERS SHALL BE COORDINATED WITH

THAT UTILITY. ALL WORK ON UTILITY EQUIPMENT SHALL BE TO UTILITY STANDARDS AND

REQUIREMENTS.OR

J

J

J

T

A

WH

E-501

A E-301

F1

P

M

J J

+48"

1 PANEL BOARD ANCHORAGE NOT TO SCALE

2 DISCONNECT SWITCH ANCHORAGE NOT TO SCALE

EAO

E25957RE

G I

S T

ER

ED PRO F E S S I ON A L ENG I NEER

S T A T E O F C A L I F O R N I A

E L E C T R I C A L

RE

B E

C C A O . K EA T I NG

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926

A

B

C

D

E

1 2 3 4 5

WOMEN

MEN

INSPECTION

BAYS

STORAGE

GENERATOR

OFFICE

A

B

C

D

E

1 2 3 4 5

438 SF

MEZZANINE

E101

ELECTRICAL SITE

PLAN

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

RK RK EAO

AS NOTED

02-02-2026

13984

CONSULTANT:

117 PARK PLACE

POINT RICHMOND

CALIFORNIA 94801

(510) 236-7435 www.intres.com

IR PROJECT #2017-050-06

STAMP:

ABCDEFGHIJKLMNOPQRSTU

ABCDEFGHIJKLMNOPQRSTU

Issue No.

Date Description

Project

Supervisor Designed Drawn Checked

File Date Vault File Number

Sheet Title

DGS Project # Work Order

Reference North Sheet Scale

Sheet Number

X

Project Manager: Anthony Brown 916 879-1021 Voice

Anthony.brown@ dgs.ca.gov

707 Third Street, 3rd Floor

Design Services Section

Facility Management Division State of California

West Sacramento, California 95605

Department of General Services

GHD Inc.

2235 Mercury Way Suite 150 Santa Rosa California 95407 USA T 1 707 523 1010 W www.ghd.com

SMITH RIVER

BORDER

STATION - HVAC

SPLIT SYSTEM

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

SHEET GENERAL NOTES

1. TYPICAL POWER CIRCUITS CONSIST OF (2) #12 AWG, #12 GND IN 3/4" RGS

CONDUIT.

2. COORDINATE EXACT LOCATION OF ELECTRICAL EQUIPMENT WITH

ARCHITECT AND MECHANICAL EQUIPMENT.

SHEET KEYNOTES

1. DISCONNECT AND REMOVE (E) BRANCH CIRCUIT PANEL, PRESERVE CIRCUITS AND

PREPARE TO RECONNECT TO (N) PANEL. PROVIDE BRANCH CIRCUIT PANEL WITH

FEATURES AS SHOWN ON PANEL SCHEDULE. PROVIDE CIRCUIT BREAKERS FOR (E)

LOADS TO MATCH ORIGINAL CIRCUIT BREAKER RATINGS. RECONNECT (E) LOADS TO (N)

PANEL.

2. PROVIDE DISCONNECT SWITCH AND POWER CIRCUIT TO INDICATED EQUIPMENT.

PANEL A 1

FC

FC

FC

FC

HP

SF

(E) FURNACE

HP

(E) GENERATOR

(PROTECT IN PLACE)

(E) LPG STORAGE TANKS

(PROTECT IN PLACE)

(E) METER MAIN SERVICE

ENTRANCE PANEL "MP"

(PROTECT IN PLACE)

1 ELECTRICAL FLOOR PLAN

SCALE: 1/4" = 1'-0"

2 MEZZANINE ELECTRICAL PLAN

SCALE: 1/4" = 1'-0"

PANEL-A, CKT-22

PANEL "MP"

PANEL "MP"

TO HP-1

TO HP-2

(E) RECEPTACLE TO REMAIN

(E) RECEPTACLE TO REMAIN

(E) RECEPTACLE TO REMAIN

(E) RECEPTACLE TO REMAIN

(E) RECEPTACLE TO REMAIN

(E) RECEPTACLE TO REMAIN

EAO

TO HP-1

TO HP-1

E25957RE

G I

ST

ER

ED PRO F E S S I ON A L ENGI NEER

S TA T E O F C A L I F O R N I A

E L E C T R I C A L

RE

B E

C C A O . K E A T I NG

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926

E601

ELECTRICAL SINGLE

LINE DIAGRAM AND

SCHEDULES

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

AS NOTED

02-02-2026

13984

CONSULTANT:

117 PARK PLACE

POINT RICHMOND

CALIFORNIA 94801

(510) 236-7435 www.intres.com

IR PROJECT #2017-050-06

STAMP:

ABCDEFGHIJKLMNOPQRSTU

ABCDEFGHIJKLMNOPQRSTU

Issue No.

Date Description

Project

Supervisor Designed Drawn Checked

File Date Vault File Number

Sheet Title

DGS Project # Work Order

Reference North Sheet Scale

Sheet Number

X

Project Manager: Anthony Brown 916 879-1021 Voice

Anthony.brown@ dgs.ca.gov

707 Third Street, 3rd Floor

Design Services Section

Facility Management Division State of California

West Sacramento, California 95605

Department of General Services

GHD Inc.

2235 Mercury Way Suite 150 Santa Rosa California 95407 USA T 1 707 523 1010 W www.ghd.com

SMITH RIVER

BORDER

STATION - HVAC

SPLIT SYSTEM

17200 US 101

SMITH RIVER, CALIFORNIA 95567

DGS PROJ #13984

200A 2P

M

(E) METER MAIN PANEL "MP"

240V 1PH

200A

METER NUMBER: 96 471 553

N G

125A

2P PANEL

A

25A 2P

20A 2P

HP-1

HP-2

SHEET KEYNOTES

1.

SHEET KEYNOTES

1. PROVIDE CIRCUIT BREAKER WITH RATINGS AS INDICATED IN (E) PANEL.

2. REPLACE (E) BRANCH CIRCUIT PANEL WITH (N) PANEL. PROVIDE BRANCH CIRCUIT

PANEL WITH FEATURES AS SHOWN ON PANEL SCHEDULE.

GENERAL NOTES

1. REFER TO SITE PLAN FOR EQUIPMENT LOCATIONS.

1 SINGLE LINE DIAGRAM

SCALE: NONE

2 ELECTRICAL SCHEDULES

SCALE: NONE

70A 2P

GENERATOR

G

(E) ATS

(E) GENERATOR 16KW

TO UTILITY

(3) #10 AWG, #10 GND IN 3/4" C

VD: 2.84%

(3) #10 AWG, #10 GND IN 3/4" C

VD: 0.94%

FEEDERS TO REMAIN

3 MECHANICAL CONNECTION SCHEDULE

SCALE: NONE

E25957RE

G I

S T

ER

ED PRO F E S S I ON A L E NGI NEER

S TA T E O F C A L I F O R N I A

E L E C T R I C A L

RE

B E

C C A O . K E A T I NG

RK RK EAOEAO

DIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP

DIV. OF THE STATE ARCHITECT

APP: INC:

REVIEWED FOR

SS FLS ACS

DATE:

01-122926

File details come from the government source that posted it. Updated .