Attachment 2 Site Plan (Att 5 in PWS)..pdf
PDF 10 MB Posted
- Attached to
- DDAY 80 Normandy American Cemetery (NOAC)
- Solicitation number
- W564KVDDAY80CemeterySynopsis
About this file
This synopsis outlines requirements for ceremony support services for the 80th Annual D-Day Celebration at the Normandy American Cemetery in France. The solicitation will require contractors to provide staging, platforms and seating; turf protection; media support; ceremonial wreaths; artificial roadways and walkways; site support; tents; power distribution; and ablution support services for an event expected to draw over 12,000 people from May 30th to June 7th, 2024. Draft performance work statements and drawings are attached as appendices to provide industry with an early view of requirements. Contractors are instructed to submit any questions on an attached spreadsheet. The Army Contracting Command will offer a site visit in Normandy, and further trip details will be provided in the forthcoming solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 1 NOAC Draft PWS.pdf | ||
| Attachment 3 IQtG ..xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAFT
542ND
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
SHEET ID
O
VE
R
AL
L
SI
TE
P
LA
N
A T
O M
AH
A
BE
AC
H C
ER
EM
O N
Y
SI
TE
2N
D E
N D
ET
F
ES
T-
A O
D C
SE
N
G U
SA
R
EU
R
W
IE
SB
AD
EN
, G
ER
M
AN
Y
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
M
AJ
. S
AN
TI
AG
O
SI
ZE
AN
SI
D
IS
SU
E D
AT
E:
U S
AR
M
Y
EU
R O
PE
O
PE
R
AT
IO
N A
TL
AN
TI
C
R
ES
O
LV
E
O-001
JUGGERNAUTS
NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.
MEDIA AREA
SEE SHEET O-003
CEREMONY SEATING AREA
SEE SHEETS O-007 THRU O-009
STAGE AREA
SEE SHEET O-010
VETERANS AREA
SEE SHEET O-004
VISITOR CENTER
(EXISTING)
GENERAL SHEET NOTES
NORTH ARROW
N
0 m 75 m 150 m
OVERALL SITE PLAN AT OMAHA BEACH CEREMONY SITE1
DV AREA
SEE SHEET O-004
HLZ AREA
SEE SHEETS O-005A THRU O-005B
FRENCH
MEDICAL TENT
MEDICAL TENT
SEE SHEET O-010
MEDIA ROW
SEE 2/O-006
LSA
SEE SHEET O-002
CONTRACTOR AREA
SEE SHEET O-002
OMAHA CEREMONY AREA
SEE 1/O-006
1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION
AND GENERAL NOTES.
2. LAYOUT ADHERES TO STANDOFF AND SEPARATION
REQUIREMENTS PER REFERENCED CODES AND
STANDARDS. REFER TO SHEET G-001.
TH
D -D
AY
C
ER
EM
O N
Y N
O R
M
AN
D Y, F R
AN
C
E
SI
TE
L
AY
O
U
TS
JM
D
JM
D
JU
N
E
MANNED 24 HOUR GUARD
SHACK PROVIDED BY ABMCDRAFT
ECUECU
ECU ECU ECU
542ND
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
TH
D -D
AY
C
ER
EM
O N
Y
SHEET ID
N O
R M
AN
D
Y, F
R
AN
C E
SI
TE
L
AY
O U
TS
O M
AH
A
D V
AN
D
V
ET
ER
AN
S
AR
EA
EN
LA
R G
ED
P
LA
N
2N
D E
N D
ET
F
ES
T-
A O
D C
SE
N
G U
SA
R
EU
R
W
IE
SB
AD
EN
, G
ER
M
AN
Y
D
ES
IG
N
ED
B
Y:
BA
S D
R
AW
N B
Y:
BA
S C
H
EC
KE
D
B Y:
M
AJ
. S
AN
TI
AG
O
SI
ZE
AN
SI
D
IS
SU
E D
AT
E:
JU
N
E
U S
AR
M
Y
EU
R O
PE
O
PE
R
AT
IO
N A
TL
AN
TI
C
R
ES
O
LV
E
O-004
JUGGERNAUTS
NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.
GENERAL SHEET NOTES
NORTH ARROW
N
OMAHA DV AND VETERANS AREA - ENLARGED PLAN1
ADA ACCESSIBLE RAMP
REFER TO NOTE 9
VETERANS TENT
20m x 50m
REFER TO NOTE 3 DISTINGUISHED
VISITOR (DV) TENT
10m x 50m
REFER TO NOTE 4
MEDICAL TENT
10m x 10m
GENERATOR AREA
ADA ACCESSIBLE
LATRINES (TYP)
HANDWASH SINK (TYP)
EXISTING FENCE LINE
(APPROXIMATE)
PORTION OF FENCE TO BE REMOVED
REFER TO NOTE 7
EXISTING GATE
1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION
AND GENERAL NOTES.
2. LAYOUT ADHERES TO STANDOFF AND SEPARATION
REQUIREMENTS PER REFERENCED CODES AND
STANDARDS. REFER TO SHEET G-001.
3. 20M X 50M VETERANS TENT IS ASSUMED TO SERVE 250
PAX MAX AT 15 SF PER PERSON.
4. 10M X 50M DV TENT IS ASSUMED TO SERVE 150 PAX
MAX AT 16 SF PER PERSON.
5. CONSTRUCT TENT PLATFORM WITH CARE;
STRUCTURAL SUPPORTS USED TO ACHIEVE A CERTAIN
ELEVATION OR LEVELNESS OF TENT FLOOR MUST BE
DESIGNED TO COMPLY WITH ALL APPLICABLE CODES
AND INSTALLATION REQUIREMENTS.
6. VETERANS TENT IS TO BE PROVIDED WITH WINDOW
WALL ALONG NW SIDE TO ALLOW VISIBILITY OF BEACH.
7. ABMC TO REMOVE PORTION OF FENCE FOR CATERING
DELIVERY. COORDINATE REMOVAL OF ADDITIONAL
FENCE PANELS AS NECESSARY.
8. ENVIRONMENTAL CONTROL UNITS (ECU) SHOWN ARE
GRAPHICAL ONLY. ECU SHALL BE PROVIDED AS
REQUIRED BY TENT MANUFACTURER.
9. ADA ACCESSIBLE RAMPS ARE TO BE PROVIDED WITH A
1:12 MAX SLOPE AND COMPLY WITH ALL OTHER
APPLICABLE CODES AND STANDARDS.
10. HAZARDOUS MATERIAL WASTE SHALL BE COLLECTED
AND STORED IN ACCORDANCE WITH APPLICABLE
ENVIRONMENTAL CODES AND REGULATIONS.
11. ABHC WILL REMOVE EXISTING SHRUBS FOR TENT
EMPLACEMENT.
12. INSTALL SIGNAGE ALONG FOOT PATHS TO DIRECT
PEDESTIRAN TRAFFIC AND INDICATE DIRECTION TO
LATRINES.
0 m 12 m 24 m
..\..\542 Polo Logo.jpg
ENVIRONMENTAL CONTROL
UNIT (TYP)
GENERAL SHEET NOTES
NORTH ARROW
N
0 m 30 m 60 m
MEDIA ROW2
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
SHEET ID
O M
AH
A
C
ER
EM
O
N Y
AR
EA
L
AY
O U
T (1
O F
4)
2N
D E
N D
ET
F
ES
T-
A O
D C
SE
N
G U
SA
R
EU
R
W
IE
SB
AD
EN
, G
ER
M
AN
Y
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
M
AJ
. S
AN
TI
AG
O
SI
ZE
AN
SI
D
IS
SU
E D
AT
E:
U S
AR
M
Y
EU
R O
PE
O
PE
R
AT
IO
N A
TL
AN
TI
C
R
ES
O
LV
E
JUGGERNAUTS
NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.
6m x 5m AREA
REF NOTE 4
1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION
AND GENERAL NOTES.
2. LAYOUT ADHERES TO STANDOFF AND SEPARATION
REQUIREMENTS PER REFERENCED CODES AND
STANDARDS. REFER TO SHEET G-001.
3. THE LAYOUT OF MEDIA AREAS IN MEDIA ROW IS
ASSUMED TO BE UNCHANGED FROM THE 75TH
ANNIVERSARY. SPACE ALLOCATION SHALL BE
ADJUSTED AS NECESSARY FOR THE 80TH
ANNIVERSARY.
4. SPACE IS ALLOCATED FOR MEDIA AREAS AS SHOWN.
MEDIA ENTITIES ARE RESPONSIBLE FOR PROVIDING
THEIR OWN FACILITIES AND UTILITIES AS NECESSARY.
5. A 6m x5m TENT PROVIDED BY USAREUR WILL INCLUDE
WIFI AND POWER.
TH
D -D
AY
C
ER
EM
O N
Y N
O R
M
AN
D Y, F R
AN
C
E
SI
TE
L
AY
O
U
TS
CEREMONY SEATING AREA
SEE SHEETS O-007 THRU O-009
STAGE AREA
SEE SHEET O-010
SEE 3/O-006
FRENCH
MEDICAL TENT
MEDICAL TENT
SEE SHEET O-010
LATRINES
SEE 3/O-006
MEDIA ROW
SEE 2/O-006
LANDING AREA
1 OVERALL CEREMONY AREA AT OMAHA BEACH
0 m 75 m 150 m
OMAHA CEREMONY AREA
4m x 4m AREA
REF NOTE 4
6m x 6m AREA
REF NOTE 4
6m x 5m AREA
REF NOTE 4
4m x 4m AREA
REF NOTE 4
4m x 4m AREA
REF NOTE 4
LATRINES (TYP)
30 m 60 m
LANDING AREA
O-006
LANDING AREA
MEDIA RISERS
AP
PR
O
AC
H
TO
S
TA
G E
CARPETED AREA
0 m
JM
D
JM
D
JU
N
E
SPACE ALLOCATED FOR MEDIA
ENTITIES (REFER TO NOTE 4)
HANDWASH SINK (TYP)
USAREUR AREA
6m x 5m
NORTH ARROW
N
CARPETED AREA
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
SHEET ID
O M
AH
A
C
ER
EM
O
N Y
AR
EA
L
AY
O U
T (2
O F
4)
2N
D E
N D
ET
F
ES
T-
A O
D C
SE
N
G U
SA
R
EU
R
W
IE
SB
AD
EN
, G
ER
M
AN
Y
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
M
AJ
. S
AN
TI
AG
O
SI
ZE
AN
SI
D
IS
SU
E D
AT
E:
U S
AR
M
Y
EU
R O
PE
O
PE
R
AT
IO
N A
TL
AN
TI
C
R
ES
O
LV
E
JUGGERNAUTS
NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.
1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION
AND GENERAL NOTES.
2. LAYOUT ADHERES TO STANDOFF AND SEPARATION
REQUIREMENTS PER REFERENCED CODES AND
STANDARDS. REFER TO SHEET G-001.
TH
D -D
AY
C
ER
EM
O N
Y N
O R
M
AN
D Y, F R
AN
C
E
SI
TE
L
AY
O
U
TS
O-007
2/O-009
1/O-008
OVERALL CEREMONY SEATING AREA AT OMAHA BEACH
0 m 30 m 60 m
1/O-009
3/O-009
4/O-009
JM
D
JM
D
JU
N
E
VIDEO SCREENDRAFT
NORTH ARROW
N
0 m 10 m 20 m
CEREMONY SEATING SECTION1
CARPETED AREA
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
SHEET ID
O M
AH
A
C
ER
EM
O
N Y
AR
EA
L
AY
O U
T (3
O F
4)
2N
D E
N D
ET
F
ES
T-
A O
D C
SE
N
G U
SA
R
EU
R
W
IE
SB
AD
EN
, G
ER
M
AN
Y
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
M
AJ
. S
AN
TI
AG
O
SI
ZE
AN
SI
D
IS
SU
E D
AT
E:
U S
AR
M
Y
EU
R O
PE
O
PE
R
AT
IO
N A
TL
AN
TI
C
R
ES
O
LV
E
JUGGERNAUTS
NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.
MEDIA RISERS
1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION
AND GENERAL NOTES.
2. LAYOUT ADHERES TO STANDOFF AND SEPARATION
REQUIREMENTS PER REFERENCED CODES AND
STANDARDS. REFER TO SHEET G-001.
3. SPEAKER STANDS & TOWERS, LIGHT STANDS &
TOWERS, VIDEO WALLS, AND SOUND BOOTH SHOWN
ON DRAWINGS ARE FOR GRAPHICAL REPRESENTATION
ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR
TO DETERMINE THE NUMBER AND SIZE OF THE
AUDIO/VISUAL FEATURES.
4. WITHIN SEATING AREA, CONSTRUCT PROTECTIVE
FRAME AROUND CONCRETE BENCHES AS NECESSARY.
5. WOODEN PLATFORM SUPPORTING SEATING AREA
SHALL BE DESIGNED AND CONSTRUCTED WITH
VIBRATION MITIGATION PER THE MEDIA EQUIPMENT
REQUIREMENTS.
6.
7.
8.
9.
10.
11.
SEAT SIZE AND SPACING SHALL COMPLY WITH IBC
REQUIREMENTS. PROPOSED LAYOUTS PROVIDES
SEATING FOR A TOTAL OF 12,469 PERSONNEL
(INCLUDING THE SEATING ON STAGE) .
THE ELEVATION CHANGE FROM THE STAGE AREA TO
THE OVERLOOK IS ACCOMPLISHED OVER THE
AVAILABLE LENGTH WITH A BUILT UP STRUCTURE. THE
STRUCTURE IS TEMPORARY AND A 1:9 RAMP DESIGN
AND CONSTRUCTION SHALL COMPLY WITH APPLICABLE
BUILDING CODES AND STANDARDS.
RAMP IS INTENDED FOR DESCENT TO OVERLOOK.
INCLUDE NON-ADA SIGNAGE. ACCESSIBILITY RAMPS
ARE TO BE PROVIDED WITH A 1:12 MAX SLOPE AND
COMPLY WITH ADA AND HOST NATION CODES AND
STANDARDS.
TRI-LEVEL MEDIA PLATFORMS ARE ISOLATED FROM
GENERAL SEATING AREA.
INSTALL SIGNAGE INDICATING FLOOR PATHS AND
DIRECTIONS TO LATRINES.
TH
D -D
AY
C
ER
EM
O N
Y N
O R
M
AN
D Y, F R
AN
C
E
SI
TE
L
AY
O
U
TS
WHEEL CHAIR SEATING (TYP)
O-008
247 SEATS
256 SEATS
240 SEATS
240 SEATS
251 SEATS
251 SEATS
260 SEATS
260 SEATS
720 SEATS
ADA ACCESSIBLE RAMP
SPEAKER STAND
SPEAKER STAND (TYP)
MEDIA
RISER
MEDIA
RISER
STAGE AREA
SEE SHEET O-010
TEMPORARY BARRIER TO SEPARATE SEATING AREAS
SOUND BOOTH
LIGHT TOWER
SPEAKER TOWER
LIGHT TOWER
SPEAKER TOWER
SPEAKER
TOWER
720 SEATS
1:9 RAMP (TYP)
REFER TO NOTE 7
ADA ACCESSIBLE RAMP (TYP)
REFER TO NOTE 9
294 SEATS
294 SEATS
MEDIAPLATFORM
JM
D
JM
D
JU
N
E
RAMP SLOPE DIRECTION
UP
END OF BUILT UP
RAMP STRUCTURE
REFER TO NOTE 7
LEVEL LANDING
REFER TO NOTE 8
COVERED BAND PLATFORM
15m x 7m
JTAC/AIR CONTROL
INTERLOCKING CROWD CONTROL BARRIER (TYP)
NORTH ARROW
N
CARPETED AREA
O-009
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
SHEET ID
O M
AH
A
C
ER
EM
O
N Y
AR
EA
L
AY
O U
T (4
O F
4)
2N
D E
N D
ET
F
ES
T-
A O
D C
SE
N
G U
SA
R
EU
R
W
IE
SB
AD
EN
, G
ER
M
AN
Y
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
M
AJ
. S
AN
TI
AG
O
SI
ZE
AN
SI
D
IS
SU
E D
AT
E:
U S
AR
M
Y
EU
R O
PE
O
PE
R
AT
IO
N A
TL
AN
TI
C
R
ES
O
LV
E
JUGGERNAUTS
NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.
1. REFER TO SHEET G-001 FOR ADDITIONAL INFORMATION
AND GENERAL NOTES.
2. LAYOUT ADHERES TO STANDOFF AND SEPARATION
REQUIREMENTS PER REFERENCED CODES AND
STANDARDS. REFER TO SHEET G-001.
3. SPEAKER STANDS, LIGHT STANDS, AND VIDEO
SCREENS SHOWN ON DRAWINGS ARE FOR GRAPHICAL
REPRESENTATION ONLY. IT IS THE RESPONSIBILITY OF
THE CONTRACTOR TO DETERMINE THE NUMBER AND
SIZE OF THE AUDIO/VISUAL FEATURES.
4. WITHIN SEATING AREA, CONSTRUCT PROTECTIVE
FRAME AROUND CONCRETE BENCHES AS NECESSARY.
5. ADA ACCESSIBLE RAMPS ARE TO BE PROVIDED WITH A
1:12 MAX SLOPE AND COMPLY WITH ALL OTHER
APPLICABLE CODES AND STANDARDS.
TH
D -D
AY
C
ER
EM
O N
Y N
O R
M
AN
D Y, F R
AN
C
E
SI
TE
L
AY
O
U
TS
CEREMONY SEATING SECTION3
0 m 10 m 20 m
REFER TO
1/O-009
REFER TO
1/O-009
450 SEATS
540 SEATS
400 SEATS
400 SEATS
400 SEATS
400 SEATS
300 SEATS
420 SEATS
380 SEATS
480 SEATS
480 SEATS
480 SEATS
480 SEATS
480 SEATS
600 SEATS
600 SEATS
513 SEATS
513 SEATS
CEREMONY SEATING SECTION
0 m 10 m 20 m
CEREMONY SEATING SECTION
0 m 10 m 20 m
CEREMONY SEATING SECTION
0 m 10 m 20 m
JM
D
JM
D
JU
N
E
ADA ACCESSIBLE RAMP (TYP)
REFER TO NOTE 5
ADA ACCESSIBLE RAMP
SPEAKER STAND
SPEAKER TOWER
VID
EO
SCREEN
VID
EO
SCREEN
VIDEO SCREEN
VIDEO SCREEN
VIDEO SCREEN
1 2 3 4 5 6 7 8 9 10
G
F
E
D
C
B
A
TH
D -D
AY
C
ER
EM
O N
Y
SHEET ID
N O
R M
AN
D
Y, F
R
AN
C E
SI
TE
L
AY
O U
TS
EN
LA
R G
ED
S
IT
E
PL
AN
A T
M O
N U
M
EN
2N
D E
N D
ET
F
ES
T-
A O
D C
SE
N
G U
SA
R
EU
R
W
IE
SB
AD
EN
, G
ER
M
AN
Y
D
ES
IG
N
ED
B
Y:
IN
IT
IA
LS
D
R
AW
N B
Y:
IN
IT
IA
LS
C
H
EC
KE
D
B Y:
M
AJ
. S
AN
TI
AG
O
SI
ZE
AN
SI
D
IS
SU
E D
AT
E:
FE
B
U S
AR
M
Y
EU
R O
PE
O
PE
R
AT
IO
N A
TL
AN
TI
C
R
ES
O
LV
E
O-010
542ND
JUGGERNAUTS
.\542 Polo Logo.jpg
NOTICE: This drawing is subject to change and provided for general information and planning purposes only. This drawing is not a build to design document.
ADA RAMP, TYP.
-REF NOTE 1
SELF-SUPPORTING OVERHEAD
STAGE STRUCTURE
-REF NOTE 4
6m W x 5m H SCREEN
WALL, TYP.
TRUSS LEGS WITH FOUNDATION
(FND) PER MANUFACTURER'S
REQUIREMENTS. FND SIZE
SHOWN IS GRAPHICAL ONLY.
GENERAL SHEET NOTES
1. ALL RAMPS ARE TO BE 2 METERS WIDE MINIMUM AND
BE PROVIDED WITH 1:12 MAX SLOPE U.N.O.
2. RAISED FLOOR STEPS ARE TO BE 203 mm AT EACH
STEP LOCATION. RAMPS WITH 1:12 MAX SLOPE ARE TO
BE PROVIDED BOTH SIDES AS SHOWN.
3. OVERHEAD STAGE STRUCTURE SHALL BE
SELF-SUPPORTING AND AVOID INTERACTION WITH ALL
EXISTING MONUMENT INFRASTRUCTURE.
4. OVERHEAD STAGE STRUCTURE SHALL BE INSTALLED
PER MANUFACTURER'S REQUIREMENTS WITH
FOUNDATION SIZED TO MINIMIZE SOIL DISTURBANCE.
OVERHEAD STRUCTURE SHALL BE DESIGNED BY A
REGISTERED DESIGN PROFESSIONAL TO RESIST ALL
LATERAL AND VERTICAL LOADS IN ACCORDANCE WITH
ALL APPLICABLE CODES AND STANDARDS.
5. DRAWINGS DEPICT A SCHEMATIC SITE DESIGN ONLY.
FURTHER DEVELOPMENT AND DESIGN IS REQUIRED TO
ENSURE COMPLIANCE WITH ALL APPLICABLE CODES
AND STANDARDS. ELEVATIONS SPECIFIED ARE TO BE
VERIFIED IN THE FIELD (V.I.F.).
10m x 10m MED TENT
ECU
ECU
TOILETS
HAND WASH SINK
UP
UP
UP
9m x m
S
TA
G E
NORTH ARROW
ENLARGED SITE PLAN AT MONUMENT
RAMP LANDING, FLAT
UP
UP
UP
..\..\542 Polo Logo.jpg
PLATFORM WITH TIERED
SEATING VIA STEPPED FLOORS
-REF NOTE 3
RAMP SLOPE DIRECTION
RAMP BY ABMC (NOT IN SCOPE)
NEW RAMP REQUIRED
ADA ACCESSIBLE SEAT
STANDARD SEAT
TIERED SEATING PLATFORM
STAGE
0 m 5 m 10 m
N
± 0.0
+635mm
UP
UP
UP
+6 m m
+8 m m
+1
1m m
+1
4m m
V.I.F.
+635mm
ELEVATION
REFERENCE
TIERED SEATING STEP, TYP.
V.I.F.
-1575mm
RAMP BOTH SIDES OF TIERED
SEATING STAGE, 1.12m WIDTH
MIN. PROVIDE HANDRAILS BOTH
SIDES AS REQUIRED.
TURF PROTECTION
AS REQUIRED, TYP.
1.2 m CLR MIN, TYP. EACH SIDE
U P
| Normandy G-000 |
| Normandy G-001 |
| G-001 |
| Normandy C-001 |
| C-001 |
| Normandy C-002 |
| C-002 |
| Normandy C-003 |
| C-003 |
| Normandy C-004 |
| C-004 |
| Normandy O-001 |
| O-001 |
| Normandy O-002 |
| O-002 |
| Normandy O-003 |
| O-003 |
| Normandy O-004 |
| O-004 |
| Normandy O-005A |
| O-005A |
| Normandy O-005B |
| O-005B |
| Normandy O-006 |
| O-006 |
| Normandy O-007 |
| O-007 |
| Normandy O-008 |
| O-008 |
| Normandy O-009 |
| O-009 |
| Normandy O-010 |
| G-001 |
| Normandy S-001 |
| S-001 |
| Normandy S-002A |
| S-002A |
| Normandy S-002B |
| S-002B |
| Normandy S-003A |
| S-003A |
File details come from the government source that posted it. Updated .