Attachment 2 Salient Charecteristics.docx
DOCX document 31 KB Posted
- Solicitation number
- 36C24923Q0060
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment 5 Knox Dental Lab Layout.pdf | ||
| 36C24923Q0060_4.docx | DOCX document | |
| Attachment 4 Knox Dental Lab Layout -.pdf | ||
| 36C24923Q0060_3.docx | DOCX document | |
| 36C24923Q0060_2.docx | DOCX document | |
| Attachment 3 Statement of Work revised.docx | DOCX document | |
| 36C24923Q0060_1.docx | DOCX document | |
| Attachment 1 Price Schedual.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Brand Name or Equal Worksheet (“Salient Characteristics”)
Item: Complete Installation of Dental Laboratory
1) Essential/significant physical, functional, or performance characteristics.
Salient characteristics are those characteristics that make an item equal to the brand name item we specify. Specifically, salient characteristics are those characteristics of the brand name item that the VA needs.
Salient Characteristics
· Must include two- year warranty for products installed by the vendor
· Must include installation by vendor (or a certified installer deemed by vendor (to avoid warranty cancellation otherwise)
· Cabinetry in polisher/sandblaster/sand vac/boilout tank/denture press area must measure total (no more than 22’6 5/8”w):
| Lower/base cabinets must include closure panel and masonite cover | |
| Lower/base cabinets in polisher work area/station must measure 3’wX 3’ 6 7/8”h | |
| Lower/base cabinet in sandvac work area/station must measure 2’6”w X 3’6 7/8”h | |
| Wall cabinetry in sandva and polisher work area/station must be 3’w X 3’h | |
| Wall cabinetry in boilout tank/denture press area must be 3’w X 3-4’h | |
| Polisher and sanvac area must not exceed 5’8” in total width space | |
| Boil out unit work area/station must measure 8’ 6” in total width | |
| Counter top affixed to polisher/sanblaster area must have 3.5 grommet for sandvac hose to collect sand | particles from sandblaster unit. |
· Vendor must supply the boilout tank unit
· Vendor must supply bench top polishing hood
· Vendor must supply sandvac
| Sandvac must be 115.00 voltage, at minimum |
| Sandvac must have 5.0 Amps, at minimum |
· Cabinetry in model trimmer/dental impression pour up work area/station must measure total of 15’w
| Lower/base cabinets must include a total width of 17’8”w | |
| Divided lower/base cabinets into sections: (1) 3’wX3’6 7/8” , (2) 2’6”w X 3’6 7/8” h, (1) 2’w X 3’ 6 7/8”, | (1) 1’ 6”w X 3’ 6 7/8” h, (1) 4’ w X 3’ 6 7/8” h lower cabinetry |
| Wall cabinetry in model trimmer/dental impression pour up work area/station must measure total 15’ w, | divided into (3) 3’w X 4’ h, (2) 3’ w X 2-3’ h |
Vendor must supply sink Vendor must supply model trimmer:
| Must be 1600 w and 3000 rpm motor, at minimum |
| Must have 121 mm work window, at minimum |
| Must supply 115 v, 60 Hz, at minimum |
| Must be 340mm h X 420 w, weight must not exceed 14.5 kg, at minimum |
· Workstations (dental lab technician) must be divided into 4 separate work areas( 2 to each area/total 4) each containing:
| 8’ w with 1/2 “overhang X 2’7 ¾” h |
| Workstations must contain self-contained dust collector and control panel for vacuum speed |
| Workstation areas must have solid/non porous surface |
| Workstation areas must each have LED overhead lighting/35watt |
| Workstation areas must each have (2) 40” case pan shelving on 14.25” support tubes |
| Workstation areas must contain air blow gun |
| Workstation areas must have ½” flex line for gas |
| Workstation areas must have 3/8” area for air connection |
| Workstations must be pre-piped and pre-wired, partially assembled prior to installation |
· Ceramic workstation area must be 10’3” w X 2’ 10 ¾” h Workstation must have self-contained dust collector and control panel for vacuum speed
· Lessor will make final utility connections
EXACT SPECIFICATIONS MUST BE MET IN ORDER FOR SQUARE FOOTAGE/SPACE ALLOTED IN NEW SITE.
File details come from the government source that posted it. Updated .