Attachment 2 - Salient Characteristics - 70Z03825QH0000121.pdf

PDF 379 KB Posted

Attached to
Purchase of Alodine Tank System
Solicitation number
70Z03825QH0000121
Issued by

About this file

This document is an Attachment 2 - Salient Characteristics for solicitation 70Z03825QH0000121, detailing specifications for an Alodine Tank System to be delivered to the U.S. Coast Guard Aviation Logistics Center. The system requires a 4-tank configuration with specific dimensional requirements (34"L x 24"W x 26"D per tank), including an Etch Tank, two Rinse Tanks, and an Alodine Tank, with the ability to adjust dimensions for build needs.

Key technical requirements include a secondary catch containment with 110% capacity of the largest tank, circulation pump systems on the Etch and Alodine tanks, pneumatic drain valve and manifold systems, polypropylene construction, lids on all tanks, and electrical components positioned above 18" from the hangar floor. The tanks must be factory new, come with an industry standard warranty, and require a Certificate of Conformance upon delivery. Compliance with EPA 40 CFR 264.175 and OSHA 29 CFR 1910.1200 regulations is mandated, with a total system length not exceeding 11 feet.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 2 – Salient Characteristics – 70Z03825QH0000121

Alodine Tank System - 4 tank system with secondary catch containment with 110% max hold capacity of the largest tank.

o Etch Tank - 34"L x 24"W x 26"D (Can be adjusted for build needs) o Rinse Tank - 34"L x 24"W x 26"D (Can be adjusted for build needs) o Alodine Tank - 34"L x 24"W x 26"D (Can be adjusted for build needs) o Rinse Tank - 34"L x 24"W x 26"D (Can be adjusted for build needs) o Secondary Catch Containment Capable of holding 110% of the largest tank; EPA 40 CFR 264.175, OSHA 29 CFR 1910.1200

Total length not to exceed 11' max Etch Tank and Alodine Tank must include a circulation pump system on the back wall of each tank.

All tanks must have drain via valve and manifold system by pneumatic pump. Manifold must come out on the right-side end and must be capable of connecting a flexible hose for HAZ Waste collection.

All tanks must have lids All tanks and Secondary Containment must be made of Polypropylene material or equivalent Electrical must be above 18" from hangar floor Industry Standard Warranty Delivery to USCG Aviation Logistics Center, HMF1 Certificate of Conformance required Tanks must be manufactured, factory new