Fire Alarm Inspection; Pine Knot JCC, KY. Federal contract opportunity
Solicitation number
1282A724Q0004
Issued by
Department of Agriculture Forest Service

About this file

This document summarizes the details of a federal solicitation for fire alarm inspection services at the Pine Knot Job Corps Center located in Pine Knot, Kentucky. The solicitation was issued by the Department of Agriculture Forest Service under number 1282A724Q0004. The solicitation seeks inspection services for the fire alarm system at the Pine Knot JCC campus. The document provides an overview of the campus layout including various buildings and structures. Relevant buildings are identified along with their current uses such as administration, housing, dining, vocational training, and recreation facilities. The campus map and floor plans attached to the document provide additional location details.

View the file

Other files for this federal contract opportunity

Other files attached to Fire Alarm Inspection; Pine Knot JCC, KY., newest first.
File Type Posted
Attachment_3_Wage_Determination_2015-4695.pdf PDF
Sol_1282A724Q0004.pdf PDF
Attachment_4_Previous_Fire_Inspection_Report.pdf PDF
Attachment_1_Statement_of_Work.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

300/310

345/346

STAFF HOUSING

R o u t e

J

O

B

C

R

P

S

R

A

D

STAFF

APARTMENTS

ABANDONED

SEWAGE

PUMPS

0 125 250 500 Feet

Existing Site Plan

Pine Knot Civilian Conservation Center

Pine Knot, Kentucky

BUILDINGS

46 - FORMER STORAGE (VACANT)

77 - TRAILER (VACANT)

100-00- ADMINISTRATION BUIL

200-00- WELL

210-10- COUNSE

220-SAFETY/CRT/COMPUTER TECH/IT

230-30- VACANT TRADE BUIL

240-40- WELDING/CENTER MAINTEN

250-50- CARPENTRY

260-60- VOCATION/WPO/

270-70- WELDING PROJECTS/TRADE MATERIAL STO

300/310- SUPPLY WAREHOUSE/FIRE CACHE

320-20- AUTO MECHANICS

360-60- FLAMMABLE STO

400-00- STUDENT ACTIVITY CE

410 HUMPHREY DORMITORY (FEMALE)

420-20- KING HALL DORM (M

430-30- PERKINS DORM (M

440-40- WASHINGTON DORM (M

450-50- LAU

500-00- ACADEMIC EDUCA

510 -DINING HALL

520-20- CULINARY

530-30- FORESTRY CONSERVATION/FIREFIGH

600-00- GYMNASIUM/RECREATION

STRUCTURES

50A-CARPENTER SHOP GAZEBO

80 - STORAGE SHED

90 - STORAGE

105-05- GAZE

115-15- GUARD S

216 - GAZEBO

225-25- GAZE

235-35- MAINTENANCE STORAGE

245-45- GAZE

255-55- CARPENTRY

305-05- GAZE

315-15- STORAGE SH

316-16- STORAGE SH

325-25- POLE BUILDING STO

335-35- GAZE

345/346- STOR GARAGE 1/

POLE BLDG STOR 1

355-55- FLEET VEHICLE KEY S

365-65- FUEL PUMPS (ABANDO

401-01- GAZE

405-05- GAZE

406-06- GAZEB

445-45- GAZEB

455-55- GAZEB

456-56- RESIDENT STO

STORAGE

RECREATION

MEDICAL/DENTAL

EDUCATION

DORMITORY

CAFETERIA

ADMINISTRATION

FUNCTION LEGEND

VACANT

5 April 2023

505-05- GAZEB

508-08- CONTAIN

515-15- DINING PAVI

517-17- STORAGE SH

521-21- GAZEB

525-STORAGE GARAGE

535-35- POLE BUILDING STORA

601-01- AMPHITHE

602-02- PAVI

603-03- STORAGE SH

605-05- GAZEB

611-11- RECREATION STORA

612-12- RECREATION STORA

613-13- RECREATION STORA

614-14- CONTAINER 2- FUEL STO

615-15- RECREATION STORA

625-25- DUG O

626-26- DUG O

Building Descriptions and Structures PINE KNOT Civilian Conservation Center

BUILDING 100 - ADMINISTRATION BUILDING

COMPUTER

PROGRAM CLERKCENTER

DIRECTOR

ADMINISTRATIVE

OFFICER

MAIL ROOM

SUPPORT

SERVICES

SUPERVISOR

CONFERENCE

ROOM

ELEC

W

M

K I T

C H

E N

DN

DN

RECEPTION

DATA RACK

PULL-DOWN

STAIR TO

ATTIC BELOW

ATTIC FLOOR

ABOVE

CONFERENCE

ROOM

OFFICE

OFFICE

BUILDING 100

ADMINISTRATION BUILDING

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

ADMINISTRATION

Building Descriptions Date: 03/06/2023Center : Pine Knot (00320) Page: 12 of 128

Building: 0100 - ADMINISTRATION BUILDING

There is a 12 gallon electric hot water heater, American Water Heater, model# E61-12U-125SVComments:

PVC None None

Electric Water Cooler Hose Bibb Lavatory Sink Water Closet (Tank)

Gas (Natural)

None None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Split Direct Expansion (Air

Cooled)

Single Duct

Fan Coil

Refrigerant

Refrigerant

Electric

Electric

Mechanical

Mechanical

None

None

Entire Building

Electronic Equipment

Room

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

The outside units are a Lenox model HS14-651-9P and Tempstar model N4A360AKC400 (mfg date April 2014)

The outside unit is a Liebert model PFH027A-PL7. This system heats and cools the computer room.

Comments:

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping System

4. Distribution System

Page: 13 of 128

Building: 0100 - ADMINISTRATION BUILDING

Comments: Electrical service of 120/240V to the building is provided from a pole-mounted utility-owned transformer (25KVA) bank, located at the west side of the building, via a 350A pole-mounted main circuit breaker.

From this circuit breaker the electrical service is routed to the building via underground cable and terminated in the 400A main distribution panelboard with 350A main circuit breaker (MCB). The utility submeter for this building is mounted at the utility pole.

FIRE ALARM

Comments: The fire alarm control panel is a Notifier SGL 404. This panel is located in the kitchen electrical closet.

Comments: The Center's main incoming communication systems (telephone and internet) are located in the computer room of this building. The public address system is not connected and therefore is not operational.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

High Intensity Discharge (HID) Comments: Building-mounted light fixtures are controlled by astronomical time clock, located in the electrical closet.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Offices

Storage Rooms

Toilets

Conference Rooms

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Distribution Panel 120/240V, 1-Phase, 3 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

Number of Deficiencies = 1

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

COMMUNICATION

Type Location N/A N/A

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required No

Number of Deficiencies = 1

BUILDING 200 - WELLNESS

EXAM 1

CMHC

CLOSET

COPYBATH 2

MEDICAL

STORAGE

BREAK ROOM

KITCHEN

TEAP

JAN

STORAGE

WAIT

RECEPTION

EXAM 2

EXAM 3

OFFICE

BATH 1

MECH

T

FEMALE

WARD

DN

MALE WARD

TLT

T

T

T

BUILDING 200

WELLNESS

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

MEDICAL/DENTAL

Page: 17 of 128

Building: 0200 - WELLNESS

Domestic hot water is provided by a Richmond model TES85-18-G 80 gallon electric water heater.Comments:

Cast Iron None None

Electric Water Cooler Lavatory Shower/Bathtub Sink Water Closet (Flush Valve)

Gas (Natural)

Wet None ABC Type Fire Extinguisher

Comments: There is a sprinkler system in the attic of the building where the mechanical equipment is located.

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Single Duct Refrigerant Electric Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

The three outside condensing units are Trane model TTB042D.Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping System

Page: 18 of 128

Building: 0200 - WELLNESS

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the north side of the building, via a 400A pole-mounted disconnect switch, that feeds the building service entrance equipment. From this main disconnect switch the electrical service is routed to the building via underground cable and terminates in the electrical trough which feeds one 400 A main panelboard with 400 A main circuit breaker and one 200 A disconnect switch.

FIRE ALARM

Comments: The fire alarm control panel is a Simplex 4007. This panel is located in the lobby.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control Panel Flow Switch Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Comments: Recorded footcandle levels include natural light contribution.

High Intensity Discharge (HID) Comments: Building-mounted lighting are controlled by astronomical time clock located in the electrical room.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Offices

Medical/Dental

Storage Rooms

Reception

Corridors & Stairs

Wards (Patient)

Toilets

Housing Lounge

Equipment Rooms (Elec/Mech)

Area Recommended Recorded Light Type

Selected Lighting w/ Battery Battery Backup

Main Distribution Panel 120/208V, 1-Phase, 3 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 2

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

LIGHTING

BUILDING 220 - SAFETY/CRT/COMPUTER TECH/IT

ORIENTATION

STAFF OFFICE

TOILET TOILET

IT

COMPUTER

SERVICE

TECHNOLOGY

UPUP

FIRST FLOOR

OFFICE

OFFICE

UP

STO.

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

NON-ACADEMIC

VOCATION/THEORY

BUILDING 220

SAFETY/CRT/COMPUTER

TECH/IT

CTR OFFICE

CTR COMPUTER

ROOM

STORAGE

DN DN

ROOF

SECOND FLOOR

DN

STORAGE

COMPUTER SERVICE

TECH ((CTR)

STORAGE

CTR OFFICE

T

SAFETY OFFICE

BUILDING 220

SAFETY/CRT/COMPUTER

TECH/IT

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

NON-ACADEMIC

ADMINISTRATION

Page: 28 of 128

Building: 0220 - SAFETY/CRT/COMPUTER TECH/IT

None None ABC Type Fire Extinguisher

Comments: Electrical service of 120/240V to the building is provided from a pole-mounted utility-owned transformer bank, located at the north side of the building, via a 600A pole-mounted main distribution panel. From this distribution panelboard the electrical service is routed to the building via underground cable and terminates in the two 225A panelboard with 225A main circuit breaker (MCB0, and two 150A main lugs only panelboards.

FIRE ALARM

Comments: The fire alarm control panel is a Simplex 4007. This panel is located in the first-floor instructor office.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Comments: Recorded footcandle levels include natural light contribution.

High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Classrooms

Offices

Storage Rooms

Vocational

Toilets

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Distribution Panel 120/240V, 1-Phase, 3 Wire Panelboard Receptacles, GFCI, Switches

Sprinkler System Stand Pipe System Fire Suppression

Emergency Exit

FIRE PROTECTION

ELECTRICAL SERVICES

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

Type Location N/A N/A

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required

Number of Deficiencies = 0

BUILDING 230 - VACANT TRADE BUILDING

TEMPORARY

STORAGE

TOILET

BUILDING 230

VACANT TRADE BUILDNG

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

VACANT

Page: 33 of 128

Building: 0230 - VACANT TRADE BUILDING

None None ABC Type Fire Extinguisher

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the east side of the building, via a 400A pole-mounted main disconnect switch that feeds the building service entrance equipment. From this disconnect switch the electrical service is routed to the building via underground cable and terminates in the 200A main panelboard with 200A main circuit breaker. Building service entrance equipment consists of one 400A main panelboard with 400A main circuit breaker (MCB), and one 200A panelboard with 200A main circuit breaker (MCB), FIRE ALARM

Comments: The fire alarm control panel is a Simplex 4001. This panel is located in the masonry shop area.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Comments: Recorded footcandle levels include natural light contribution.

Incandescent Comments: The exterior building-mounted light fixtures are controlled by a photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Classrooms

Offices

Storage Rooms

Toilets

Vocational

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Panelboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, Switches

Sprinkler System Stand Pipe System Fire Suppression

Emergency Exit

FIRE PROTECTION

ELECTRICAL SERVICES

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

Type Location N/A N/A

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required No

BUILDING 240 - WELDING/CENTER MAINTENANCE

FIRST FLOOR

MEZZANINE

STORAGE

OFFICE

MAITENANCE

SHOP

FLAMMABLE &

PAINT

STORAGE

TOOL

STORAGE

WELDING

SHOP

GRINDING

SHOP

OXYGEN/

ACETYLENE

STORAGE

TOILET

OFFICE

CLASSROOM

STORAGE

STORAGE

STORAGE

T

WELDING/CENTER

MAINTENANCE

BUILDING 240

60 Feet15 300

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

VOCATION/THEORY

STORAGE/SUPPORT

Page: 38 of 128

Building: 0240 - WELDING/CENTER MAINTENANCE

Domestic hot water is provided by a US/Craftmaster model E1F50RD045V 50-gallon electric water heater.

Comments:

Cast Iron None None

Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Multi-Compartment Sink Urinal Water Closet (Tank)

Gas (Natural)

None None ABC Type Fire Extinguisher

Comments: Electrical service of 120/240V to the building is provided from a pole-mounted utility-owned transformer bank, located at the east side of the building, via a 1,200A pole-mounted main disconnect switch that feeds the building service entrance equipment. From this disconnect switch the electrical service is routed to the building via underground cable and terminates in the 1,200A main distribution panelboard with 1,200A main circuit breaker. Building electrical equipment consists of one 1,200A main distribution panelboard (MDP) with 1,200A main circuit breaker (MCB), one 400A panelboard with 400A main circuit breaker (MCB), two 225A panelboards with 225A MCB, and two 200A panelboards with 200A MCB.

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Incandescent Comments: The exterior building-mounted light fixtures are controlled by a photocell.

Main Panelboard 120/240V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Page: 39 of 128

Building: 0240 - WELDING/CENTER MAINTENANCE

FIRE ALARM

Comments: The fire alarm control panel is a Fire-Lite MS4424B. This panel is located in the paint shop area.

Comments: The building is connected to the LAN.

Audible Alarm Control Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

T8 - Fluorescent

T8 - Fluorescent

T12 - Fluorescent

T12 - Fluorescent

High Intensity Discharge (HID)

Incandescent

T12 - Fluorescent

Offices

Classrooms

Storage Rooms

Vocational

Vocational

Vocational

Toilets

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Emergency Exit

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

Make Up air systems are deteriorated, and there is no exhaust system for the Welding Shop.

Interior Lighting2.

Emergency /Exit Lighting3.

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING UTILITY METERING

Structure: Good Exterior: Good Interior: Good Mechanical: Poor Electrical: Fair

Type Location N/A N/A

CARBON MONOXIDE DETECTION

Detection Required No

Number of Deficiencies = 0

IMPAIRMENT

BUILDING 250 - CARPENTRY SHOP

CARPENTRY SHOP

DUST COLLECTOR

OFFICE

CARPENTRY

CLASS

TOILET

STORAGE

TOILET

STORAGE

STORAGE

STORAGE

BUILDING 250

CARPENTRY SHOP

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

Page: 44 of 128

Building: 0250 - CARPENTRY SHOP

Two electric water heaters are 10 gallon each Richmond model 6EP10-1.Comments:

Cast Iron None None

Electric Water Cooler Fixed Emergency Eyewash Hose Bibb Lavatory Sink Water Closet (Tank)

Gas (Natural)

None None ABC Type Fire Extinguisher

Comments: Electrical services of 120/208V, 1-phase and 3-phase to the building are provided from a pole-mounted utility-owned transformer bank located at the northeast side of the building via overhead cable to one 200A, 3-pole main circuit breaker (MCB), one 200A, 2-pole main circuit breaker, and one 100A, 120/208V, 1-phase panelboard with 100A main circuit breaker (MCB) located in the carpentry shop.

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Incandescent Comments: The exterior building-mounted light fixtures are controlled by a photocell.

Main Circuit Breaker 120/240V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

ELECTRICAL SERVICES Number of Deficiencies = 3

Page: 45 of 128

Building: 0250 - CARPENTRY SHOP

FIRE ALARM

Comments: The fire alarm control panel is a Siemens FS-250 located in the carpentry shop.

Comments: The building is connected to the LAN. The public address system is not connected and therefore is not operational.

Audible Alarm Control Panel Duct Smoke Detector Heat Detector Manual Pull Station Visual Alarm

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

T8 - Fluorescent

T12 - Fluorescent

T12 - Fluorescent

High Intensity Discharge (HID)

T12 - Fluorescent

Classrooms

Offices

Storage Rooms

Vocational

Toilets

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Emergency Exit

Number of Deficiencies = 2

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

Two electrical panels are more than forty years old, deteriorated, overloaded and undersized for the existing loads.

There is no heat in the Shop area.

Interior Lighting2. Number of Deficiencies = 1

Emergency /Exit Lighting3.

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING UTILITY METERING

Structure: Good Exterior: Good Interior: Good Mechanical: Fair Electrical: Poor

Type Location N/A N/A

CARBON MONOXIDE DETECTION

Detection Required No

Number of Deficiencies = 0

BUILDING 260 - VOCATION/WPO/AWPO

OFFICE

ASSIST. WPO

CONFERENCE

WPO/CONFERERRNCE ROOM

TOILET

W

M

CLOSET

OFFICE

COPY ROOM

OFFICE

BUILDING 260

VOCATION/WPO/AWPO

20 Feet100 5

PINE KNOT CIVILIAN CONSERVATION

CENTER

STORAGE SUPPORT

Page: 49 of 128

Building: 0260 - VOCATION/WPO/AWPO

There is a 30 gallon electric water heater, Richmond model 6K30-2.Comments:

Cast-Iron None None

Electric Water Cooler Lavatory Sink Urinal Water Closet (Tank)

Gas (Natural)

None None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Packaged Direct

Expansion (Air Source)

Single Duct None Electric Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Cooling is provided by the same units that provide heating. The model numbers are given under heating.

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping System

Page: 50 of 128

Building: 0260 - VOCATION/WPO/AWPO

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank located at the northwest side of the building via underground cable and terminates in the 200A main branch panelboard with 200A main circuit breaker (MCB).

FIRE ALARM

Comments: The fire alarm control panel is by Simplex 4007. This panel is located in the maintenance office.

Comments: The building is connected to the LAN. The public address system is not connected and therefore is not operational.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None None

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

Incandescent Comments: The exterior building-mounted light fixtures are controlled by a photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Offices

Storage Rooms

Conference Rooms

Toilets

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Branch Panel 120/208V, 1-Phase, 3 Wire Branch Panel Only Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

COMMUNICATION

Electric Water Gas No NoNo

BUILDING UTILITY METERING

Type Location N/A N/A

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required

BUILDING 300/0310 - SUPPLY WAREHOUSE/FIRE CACHE

WAREHOUSE

FIRE FIGHTING/

URBAN FORESTRY

OFFICE

LOADING

DOCK

T

DN

DN

FIRE FIGHTING/

URBAN FORESTRY

STORAGE

OFFICE

SUPPLIES

CLOTHES

STORAGE

MVD

BUILDING 300/310

SUPPLY WAREHOUSE/FIRE CACHE

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

VOCATION/THEORY

Page: 59 of 128

Building: 0300/0310 - SUPPLY WAREHOUSE/FIRE CACHE

There is a 10 gallon electric hot water heater, Richmond model 6EP-1.Comments:

Cast Iron None None

Electric Water Cooler Lavatory Water Closet (Tank)

Comments: Richmond 6EP10-1, 10 Gallon electric water heater

Gas (Natural)

None None ABC Type Fire Extinguisher

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the north side of the building, via a 200A pole-mounted circuit breaker that feeds the building service entrance equipment. From this disconnect switch the electrical service is routed to the building via underground cable and terminated in the 200A main panelboard with 200A main circuit breaker (MCB).

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Incandescent Comments: The exterior building-mounted light fixtures are controlled by a photocell.

Main Panelboard 120/240V, 3-Phase, 4 Wire Panelboard Receptacles, Switches

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Page: 60 of 128

Building: 0300/0310 - SUPPLY WAREHOUSE/FIRE CACHE

FIRE ALARM

Comments: The fire alarm control panel is a Honeywell 6700 located in the warehouse area.

Comments: The building is connected to the LAN.

Audible Alarm Control Panel Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None None

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

T12 - Fluorescent

T12 - Fluorescent

T8 - Fluorescent

T12 - Fluorescent

Offices

Storage/Warehouse-Active

Classrooms

Toilets

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Emergency Exit

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 1

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING UTILITY METERING

Structure: Good Exterior: Good Interior: Good Mechanical: Good Electrical: Good

Type Location N/A N/A

CARBON MONOXIDE DETECTION

Detection Required No

Number of Deficiencies = 0

IMPAIRMENT

Potentially Impaired

DOL Responded

DOL Determination

Potential Impaired Comments DOL Determination Discussion/Comments

BUILDING 320 - AUTO MECHANICS SHOP

TOILET TOILET

AUTO MECHANICS

SHOP

AUTO MECHANICS

CLASSROOM

OFFICE

TOOL ROOM

CLASSROOM

RECYCLING

STORAGE

STORAGE

BUILDING 320

AUTO MECHANICS SHOP

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

Page: 64 of 128

Building: 0320 - AUTO MECHANICS SHOP

Domestic hot water is provided by a Richmond Perfect 30-gallon water heater.Comments:

Comments:

Cast Iron Outdoor None

A grease and oil interceptor is installed outside the building, on the northeast corner adjacent to the sewage lift station.

Electric Water Cooler Fixed Emergency Eyewash Sink Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the southeast side of the building, via two circuit breakers, one 225A pole-mounted circuit breaker and one 225A wall-mounted circuit breaker that feeds the building service entrance equipment. Building service entrance equipment consists of two 225A main panelboards with 225A main circuit breakers.

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.

Main Panelboard 120/208V, 1-Phase, 3 Wire Panelboard Receptacles, Switches

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

ELECTRICAL SERVICES Number of Deficiencies = 2

Page: 65 of 128

Building: 0320 - AUTO MECHANICS SHOP

FIRE ALARM

Comments: The fire alarm control panel is a Siemens FS-250. This panel is located in the office.

Comments: The building is connected to the LAN.

Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

High Intensity Discharge (HID)

T8 - Fluorescent

Classrooms

Offices

Storage Rooms

Vocational

Toilets

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Emergency Exit

GENERAL BUILDING CONDITION

Rating X Good

Fair Poor

Interior Lighting2.

Emergency /Exit Lighting3.

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No NoNo

BUILDING UTILITY METERING

Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good

Type Location N/A N/A

CARBON MONOXIDE DETECTION

Detection Required No

Number of Deficiencies = 0

IMPAIRMENT

Potentially Impaired

DOL Responded

DOL Determination

Potential Impaired Comments DOL Determination Discussion/Comments

BUILDING 400 - STUDENT ACTIVITY CENTER

W M

T

JAN

NIGHT

SHIFT

MAIL ROOM

RESIDENTIAL

MANAGER

RESIDENTIAL

SUPERVISOR

STORAGE

CSO

LOUNGE

STORAGESTUDENT

GOV.ASSOC.

OFFICE

CANTEEN

RAMP

DN

FIREPLACE

DEPUTY

CENTER

DIRECTOR

MEDICATION

ROOM

BUILDING 400

STUDENT ACTIVITIES

CENTER

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

ADMINISTRATION

RECREATION

HOUSING

MEDICAL/DENTAL

Page: 72 of 128

Building: 0400 - STUDENT ACTIVITY CENTER

Domestic hot water is provided by a 20-gallon electric water heater.Comments:

PVC None None

Electric Water Cooler Lavatory Sink Urinal Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher

Copper Copper Electric Building Water Softener No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Direct Expansion (Air

Source)

Single Duct Refrigerant Electric Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

The furnaces are provided with evaporator coils matched to Lennox outdoor air cooled condensing units. One is a model HS26-060-2P and one is a model HS26-048-2P.

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping

Page: 73 of 128

Building: 0400 - STUDENT ACTIVITY CENTER

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the south side of the building, via a 400A pole-mounted disconnect switch. From this distribution panelboard the electrical service is routed to the building via underground cable and terminates in the 400A panelboard with 300A main circuit breaker (MCB).

FIRE ALARM

Comments: The fire alarm control panel is a Simplex 4007. This panel is located in the residential manager's office.

Comments: The building is connected to the LAN.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None None

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

Incandescent Comments: The exterior building-mounted light fixtures are controlled by a photocell.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

High Intensity Discharge (HID)

Offices

Corridors & Stairs

Storage Rooms

Lounges

Study Room

Area Recommended Recorded Light Type

None Battery Backup

Main Branch Panel 120/208V, 1-Phase, 3 Wire Branch Panel Only Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

COMMUNICATION

Type Location N/A N/A

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required No

BUILDING 410 - HUMPHREY DORMITORY (FEMALE)

DORM ROOMS

(TYPICAL)

DORM ROOMS

(TYPICAL)

TOILET/SHOWERS

TOILET/SHOWERS

M E

C H

DORM ROOMS

(TYPICAL)

DORM ROOMS

(TYPICAL)

R.A.

LOUNGE

STORAGE

J

STORAGE

J

STORAGE

DN

STORAGE

BUILDING 410

HUMPHREY DORMITORY

(FEMALE)

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

STUDENT HOUSING

Page: 77 of 128

Building: 0410 - HUMPHREY DORMITORY (FEMALE)

There are two 120 gallon hot water heaters. One is a Rheemglass model EGS18-120G and the other is a Richmond Perfect model TES120-36G.

Comments:

Cast Iron None None

Electric Water Cooler Hose Bibb Lavatory Shower Shower/Bathtub Sink Water Closet (Flush Valve)

None

Wet None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Heat Pump (Air

Source)

Single Duct Refrigerant Electric Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

There are two outside heat pump units. One unit is a Trane model TWA060C300A and the other unit is a Maytag model DT5BD-060K.

Comments:

Number of Deficiencies = 1

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3. Number of Deficiencies = 1

Fuel Distribution4.

Number of Deficiencies = 1FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping System

Page: 78 of 128

Building: 0410 - HUMPHREY DORMITORY (FEMALE)

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the east side of the building, via a 400A pole-mounted main circuit breaker. From this circuit breaker the electrical service is routed to the building via underground cable and terminates in the 400A main panelboard with 400A main circuit breaker (MCB). The service equipment is located in the electrical/mechanical room.

FIRE ALARM

Comments: The fire alarm control panel is a Siemens FS-250. This panel is located in the RA office.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Flow Switch Heat Detector Manual Pull Station Smoke Detector Tamper Switch Visual Alarm

Comments: Recorded footcandle levels include natural light contribution.

Light Emitting Diode (LED) Comments: The exterior building-mounted light fixtures are controlled by a time clock.

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Sleeping Rooms

Offices

Storage Rooms

Equipment Rooms (Elec/Mech)

Shower

Laundry Room

Housing Lounge

Corridors & Stairs

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Panelboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 1

Type Location None None

There is no gas in this building.

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required

BUILDING 420 - KING HALL DORMITORY (MALE)

MECH/ELEC

LOWER LEVEL

UP

UP

T T

OFFICE

IT

OFFICE

OFFICE

OFFICE

OFFICE

BUILDING 420

KING HALL DORMITORY

(MALE)

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

ADMINISTRATION

RECREATION

DORM ROOMS

(TYPICAL)

DORM ROOMS

(TYPICAL)

TOILET/SHOWERS

TOILET/SHOWERS

MECH

DORM ROOMS

(TYPICAL)

DORM ROOMS

(TYPICAL)

R.A. OFFICE

LOUNGE

RAMP

RAMP

STORAGE

FIRST FLOOR

JAN

JAN

DN

DN

DN

DN

BUILDING 420

KING HALL DORMITORY

(MALE)

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

Page: 82 of 128

Building: 0420 - KING HALL DORMITORY (MALE)

There are two 120 gallon each electric hot water heaters. One is a Rheem model EGS18-120-G and the other is a Bradford White model MII120-18-3SF-39.

Comments:

Cast Iron None None

Electric Water Cooler Hose Bibb Lavatory Service Sink Shower Urinal Water Closet (Flush Valve)

None

None None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Heat Pump (Air

Source)

Single Duct Refrigerant Electric Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Three split system heat pumps serve the dorm. The three outdoor units for the dorm are as follows:

Rudd-Rheem model RP1424AJINA (mfg 2/2017), Tempstar model N4H3609HB400 (mfg 2/2011) and International Comfort Products model R2H360GHR4.

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping System

Page: 83 of 128

Building: 0420 - KING HALL DORMITORY (MALE)

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the northwest side of the building, via a 600A pole-mounted main circuit breaker. From this circuit breaker the electrical service is routed to the building via underground cable and terminated in the 600A main panelboard with 600A main circuit breaker (MCB). The service equipment is located in the electrical/mechanical room.

FIRE ALARM

Comments: The fire alarm control panel is a Simplex 4007. This panel is located in the RA office.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Comments: Recorded footcandle levels include natural light contribution.

Light Emitting Diode (LED) Comments: Building-mounted lighting is controlled by an astronomical time clock located in the electrical/mechanical room.

T8 - Fluorescent

T8 - Fluorescent

Compact Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T12 - Fluorescent

Compact Fluorescent

T8 - Fluorescent

Sleeping Rooms

Offices

Storage Rooms

Housing Lounge

Corridors & Stairs

Shower

Equipment Rooms (Elec/Mech)

Toilets

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Panelboard 120/240V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

Type Location None None

There is no gas in this building.

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required

BUILDING 430 - PERKINS DORMITORY (MALE)

DORM ROOM

(TYPICAL)

DORM ROOM

(TYPICAL)

STORAGE

LOUNGE

DORM ROOM (TYPICAL)

DORM ROOM (TYPICAL)

M E

C H

R.A. OFFICE

RAMP RAMP

JAN

JAN

RAMP

R A

M P

STORAGE

DN

DN

DN

STORAGE

DN

UNDER

CONSTRUCTION

UNDER

CONSTRUCTION

BUILDING 430

PERKINS DORMITORY

(MALE)

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

Page: 87 of 128

Building: 0430 - PERKINS DORMITORY (MALE)

Domestic hot water is provided by two Bradford White model MII120-183SF39 120 gallon electric water heaters.

Comments:

Cast Iron None None

Electric Water Cooler Hose Bibb Lavatory Shower Sink Urinal Water Closet (Flush Valve)

None

None None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Heat Pump (Air

Source)

Single Duct Refrigerant Electric Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Outdoor units are Trane model 2TWA0060A3000AB, and Goodman CPLJ48-1B plus International Comfort Product model X12147111, mfg date April 2012.

Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

Number of Deficiencies = 1FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping

Page: 88 of 128

Building: 0430 - PERKINS DORMITORY (MALE)

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the west side of the building, via a 600A pole-mounted main circuit breaker. From this circuit breaker the electrical service is routed to the building via underground cable and terminated in the 600A main panelboard with 600A main circuit breaker (MCB). The service equipment is located in the electrical/mechanical room.

FIRE ALARM

Comments: The fire alarm control panel is a Simplex 4007. This panel is located in the RA office.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Comments: Recorded footcandle levels include natural light contribution.

High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.

T8 - Fluorescent

T8 - Fluorescent

Compact Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Sleeping Rooms

Offices

Storage Rooms

Housing Lounge

Corridors & Stairs

Shower

Toilets

Equipment Rooms (Elec/Mech)

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Panelboard 120/240V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

Type Location None None

There is no gas in this building.

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required No

BUILDING 440 - WASHINGTON DORMITORY (MALE)

LOUNGE

R.A. OFFICE

DORM ROOM

(TYPICAL)

STORAGE

DORM ROOM

(TYPICAL)

DORM ROOM

(TYPICAL)

TOILET/SHOWERS

MECH

DORM ROOM

(TYPICAL)

STORAGE

STORAGE

STORAGE

JAN

JAN

DN

DN

STORAGE

BUILDING 440

WASHINGTON DORM (MALE)

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

Page: 92 of 128

Building: 0440 - WASHINGTON DORMITORY (MALE)

Domestic hot water is provided by two 120 gallon electric water heaters. One water heater is a Bradford White model MII120-18-35F-39 and the other is a Richmond Perfect model ES-TES120- 18G.

Comments:

Cast Iron None None

Electric Water Cooler Hose Bibb Lavatory Service Sink Shower Urinal Water Closet (Flush Valve)

None

None None ABC Type Fire Extinguisher

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Split Heat Pump (Air

Source)

Single Duct Refrigerant Electric Mechanical None Entire Building

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Cooling is provided by three split system heat pumps, data for which is provided under heating.Comments:

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping System

Page: 93 of 128

Building: 0440 - WASHINGTON DORMITORY (MALE)

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the west side of the building, via a 600A pole-mounted main circuit breaker. From this circuit breaker the electrical service is routed to the building via underground cable and terminates in the 600A main panelboard with 600A main lugs only (MLO). The service equipment is located in the electrical/mechanical room.

FIRE ALARM

Comments: The fire alarm control panel is a Simplex 4007. This panel is located in the RA office.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control/Annunciator Panel Duct Smoke Detector Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Comments: Recorded footcandle levels include natural light contribution.

Light Emitting Diode (LED) Comments: The exterior building-mounted light fixtures are controlled by a time clock.

T8 - Fluorescent

Incandescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Sleeping Rooms

Storage Rooms

Offices

Housing Lounge

Corridors & Stairs

Shower

Laundry Room

Equipment Rooms (Elec/Mech)

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Panelboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3. Number of Deficiencies = 1

Type Location None None

There is no gas in this building.

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required

BUILDING 450 - LAUNDRY

MECH

LAUNDRY

MECH.

TOILET

JAN/

STORAGE

COMMERCIAL

WASHER &

DRYER

BUILDING 450

LAUNDRY

20 Feet100 5

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

Page: 97 of 128

Building: 0450 - LAUNDRY

Hot water is provided by two 100 gallon each Bradford White model EF100T250E3NA2 gas-fired water heaters.

Comments:

Comments:

Cast Iron None None

There is an external lint trap installed on the sewer outside the building.

Electric Water Cooler Hose Bibb Lavatory Sink Water Closet (Tank)

Gas (Natural)

None None ABC Type Fire Extinguisher

Copper Copper Gas-Fired None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

None None None None Natural None None

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

System Type

Air Distribution

Piping System

Control System

Fresh Air Intake

Energy Conservation Area

Served

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

3. Air Conditioning

Area Served

Control System

Heat Distribution

Fresh Air Intake

Piping

4. Distribution System Number of Deficiencies = 1

Page: 98 of 128

Building: 0450 - LAUNDRY

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the north side of the building, via a 600A pole-mounted disconnect switch. From this disconnect switch the electrical service is routed to the building via underground cable and terminates in the 400A main panelboard with 400A main circuit breaker (MCB).

FIRE ALARM

Comments: The fire alarm control panel is a Fire-Lite Alarms- MS 2. This panel is located in the storage room. There are some smoke detectors which are battery operated.

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

Audible Alarm Control Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm

None Closed Circuit TV None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.

T8 - Fluorescent

T8 - Fluorescent

T12 - Fluorescent

Laundry Room

Toilets

Equipment Rooms (Elec/Mech)

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Main Panelboard 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Emergency Exit

ELECTRICAL SERVICES

Exterior Lighting1.

Interior Lighting2.

Emergency /Exit Lighting3.

COMMUNICATION

Electric Water Gas No NoNo

BUILDING UTILITY METERING

Type Location N/A N/A

CARBON MONOXIDE DETECTION

LIGHTING

Detection Required No

BUILDING 500 - ACADEMIC EDUCATION

FIRST FLOOR

MECH

M

W

STUDENT STORAGE

COPY

CLASSROOM

UPUP

MECH

CPP/

TABE

OFFICE

OFFICE

CLASSROOM

OFFICE

CPP/

TABE

BUILDING 500

ACADEMIC EDUCATION

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

ACADEMIC

NON-ACADEMIC

SECOND FLOOR

COMPUTER

LAB

CLASSROOM

STAFF

LOUNGE

M W

CUSTODIAL

ROOM AND

STAFF TOILET

JAN

STORAGE/

MEDS

PRINCIPAL

COPY ROOM

STORAGE

LIBRARY

LANGUAGE

ARTS

CLASSROOM

DN DN DN

CLASSROOM

CLASSROOM

BUILDING 500

ACADEMIC EDUCATION

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

ACADEMIC

Page: 103 of 128

Building: 0500 - ACADEMIC EDUCATION

Hot water is provided by a 30 gallon electric water heater.Comments:

Cast Iron Outdoor None

Electric Water Cooler Lavatory Service Sink Urinal Water Closet (Flush Valve)

None

None None ABC Type Fire Extinguisher

Comments: Electrical service of 120/208V to the building is provided from a pole-mounted utility-owned transformer bank, located at the south side of the building, via a 600A pole-mounted main disconnect switch. From this disconnect switch the electrical service is routed to the building via underground cable and terminated in the trough. Building service entrance equipment consists of two 225A main panelboards with 225A main circuit breaker (MCB), and one 400A 3-pole disconnect switch. The service equipment is located in the electrical/mechanical room.

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.

Main Panelboards 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, Switches

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Water Distribution1.

Sanitary Distribution2.

Fixtures3.

Fuel Distribution4.

FIRE PROTECTION

ELECTRICAL SERVICES Number of Deficiencies = 1

Exterior Lighting1.

Page: 104 of 128

Building: 0500 - ACADEMIC EDUCATION

FIRE ALARM

Comments: The fire alarm control panel is a Simplex 4001. This panel is located in the educational office on the second floor.

Comments: The public address system is not connected and therefore not operational.

Audible Alarm Control/Annunciator Panel Heat Detector Manual Pull Station Smoke Detector Visual Alarm

Connected to Main System None None TV with VCR

Telephone Security Public Address Television

Comments: Recorded footcandle levels include natural light contribution.

Incandescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

T8 - Fluorescent

Storage Rooms

Offices

Classrooms

Toilets

Equipment Rooms (Elec/Mech)

Housing Lounge

Corridors & Stairs

Area Recommended Recorded Light Type

Battery Backup Battery Backup

Emergency Exit

GENERAL BUILDING CONDITION

Rating

Comments:

X Good Fair Poor

Exterior doors, frames and sidelights are damaged.

Interior Lighting2.

Emergency /Exit Lighting3.

COMMUNICATION

The facility condition is not impacting the functional use of the facility.

The facility condition IS impacting the functional use of the facility.

The facility condition IS SIGNIFICANTLY impacting the functional use of the facility.

Electric Water Gas No N/ANo

BUILDING UTILITY METERING

Structure: Good Exterior: Fair Interior: Good Mechanical: Good Electrical: Good

Type Location N/A N/A

CARBON MONOXIDE DETECTION

Detection Required No

BUILDING 510 - DINING HALL

DINING

SERVING

JAN

M

W

MECH

TRASH CANS

FREEZERS

DRY FOOD

STORAGE

OFFICE

CULINARY ARTS

DISHWASHING

KITCHEN

FREEZER

STORAGE

DN

LOADING

DOCK

DN

PANTRY/

STORAGE

BUILDING 510

DINING HALL

40 Feet200 10

PINE KNOT CIVILIAN CONSERVATION

CENTER

PINE KNOT, KENTUCKY

FOOD SERVICE

Page: 109 of 128

Building: 0510 - DINING HALL

Domestic hot water is provided by two 100 gallon Bradford White model D100T1993M gas-fired water heaters.

Comments:

Cast Iron Outdoor None

Electric Water Cooler Hose Bibb Lavatory Multi-Compartment Sink Water Closet (Flush Valve)

Gas (Natural)

None None ABC Type Fire Extinguisher, K Type Fire Extinguisher, Wet Chemical

Comments: Electrical service of 120/208V to the building is provided from a pad-mounted utility-owned transformer, located at the west side of the building, via underground cable and terminated in the 1,600A main distribution panelboard (MDP) with 1,600A main circuit breaker (MCB). The service equipment is located in the electrical/mechanical room.

Copper Copper Electric None No

Hot Water Cold Water Water Heater Water Treatment HW Storage Tank

Grease InterceptorWaste / Vent Interior Storm

Service Entrance Electrical Characteristics Distribution Equipment Wiring Devices

High Intensity Discharge (HID) Comments: The exterior building-mounted light fixtures are controlled by a photocell.

Main Distribution Panel 120/208V, 3-Phase, 4 Wire Panelboard Receptacles, GFCI, Switches

Sprinkler System Stand Pipe System Fire Suppression

PLUMBING

Wat…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .