Attachment 2 - Minimum Salient Characteristics.pdf
PDF 100 KB Posted
- Attached to
- Air compressor Replacement (brand name or equal)
- Solicitation number
- FA302026Q0093
About this file
This document is a Minimum Salient Characteristics Summary that establishes baseline technical specifications for a high-pressure breathing air compressor system procurement, with BAUER Compressors identified as the benchmark standard or approved equal.
The required system encompasses eight integrated components: (SC01) a four-stage, air-cooled compressor block rated for minimum continuous operating pressure of 6,000 PSI with a minimum charging rate of 13.0 SCFM to enable rapid recharge cycles; (SC02) a three-position containment fill station certified to NFPA 1901 standards accommodating SCBA and SCUBA cylinders up to 31 inches in length with simultaneous dual and tri-fill capability for operator blast protection; (SC03) four ASME-certified 6,000 PSI air storage cylinders securely mounted in an integrated rear rack assembly unified with the compressor frame to provide high-volume cascade storage; (SC04) a multi-stage breathing air purification system producing air compliant with CGA Grade E and NFPA 1989 standards, equipped with real-time Carbon Monoxide and Hydrogen Sulfide gas monitors featuring visual and audible fault alarms; (SC05) an Industrial Programmable Logic Controller with minimum 7.0-inch color touchscreen HMI, automatic condensate drain system, and automatic safety shutdown for low oil pressure, high temperature, and over-pressurization; (SC06) a heavy-duty sound-attenuated acoustic cabinet enclosure with an integrated 100-foot high-pressure hose on heavy-duty reel and external/remote fill port for refilling mobile apparatus; (SC07) maximum exterior dimensions not exceeding 101" L × 38" W × 78" H with fully assembled operational weight between 4,350 and 4,550 lbs to ensure fitment onto existing concrete floor pads; and (SC08) turnkey services including site survey, delivery, rigging, physical anchoring, utility tie-ins, independent certified air sample analysis, legacy unit deinstallation/disposal, and operator training.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Minimum Salient Characteristics Summary
Vendors must indicate whether their proposed system (benchmark or equal) meets or exceeds the following baseline specifications:
Benchmark Standard: BAUER Compressors (or approved equal)
Item
Salient Characteristic Category
Minimum Required Technical Specification / Threshold
Operational Function
SC-
Compressor Assembly
Four-stage, air-cooled, high-pressure breathing air compressor block rated for a minimum continuous operating pressure of 6,000 PSI with a minimum charging rate of 13.0 SCFM.
Rapid recharge cycles for high-pressure breathing air systems.
SC-
Containment Fill Station
Three (3) position containment fill station certified to NFPA 1901 standards; accommodates SCBA and SCUBA cylinders up to 31 inches in overall length;
provides simultaneous dual and tri-fill capability at all three positions.
Operator blast protection during simultaneous cylinder recharging.
SC-
Air Storage System
Four (4) ASME-certified 6,000 PSI air storage cylinders securely mounted in an integrated rear rack assembly unified with the compressor frame.
High-volume cascade storage reserve without external detached racks.
SC-
Purification & Monitoring
Multi-stage breathing air purification system producing air compliant with CGA Grade E and NFPA 1989; equipped with real-time Carbon Monoxide (CO) and Hydrogen Sulfide (H₂S) gas monitors with visual and audible fault alarms.
Eliminates toxic air contamination risks for emergency responders.
SC-
Automation & Safety Controls
Industrial Programmable Logic Controller (PLC) with a minimum 7.0-inch color touchscreen HMI;
automatic condensate drain system with collection reservoir; automatic safety shutdown for low oil pressure, high temperature, and over-pressurization.
Automated fail-safe protection and simplified user operation.
SC-
Auxiliary Fill & Noise Control
Heavy-duty sound-attenuated acoustic cabinet enclosure; integrated 100-foot high-pressure hose on heavy-duty reel; external/remote fill port configured to refill exterior apparatus and mobile vehicle-mounted cascade systems.
Noise suppression in station; remote refilling of mobile fire apparatus.
SC-
Physical Footprint & Weight
Maximum exterior dimensions must not exceed 101" L × 38" W × 78" H; fully assembled operational weight must remain between 4,350 lbs and 4,550 lbs.
Strict physical and structural fitment onto existing concrete floor pad.
SC-
Turnkey Services
Site survey, delivery, rigging, physical anchoring, utility tie-ins, independent certified air sample analysis, legacy unit de-installation/disposal, and operator training.