Attachment 2 - Lake Baldwin Asbestos Report BLD 500.pdf

PDF 34 MB Posted

Attached to
DESIGN-BUILD (DB) CONSTRUCTION: Project 675-26-100 - Refresh Lake Baldwin Pharmacy Finishes
Solicitation number
36C24825R0169
Issued by

About this file

This document is a Baseline Asbestos Assessment Survey for Building 500 at the Lake Baldwin Orlando VA Medical Center, conducted by Thunderbird-HRP JV, LLC in October 2024. The comprehensive survey identified multiple areas containing asbestos-containing materials (ACM), primarily on the first floor, including flooring materials, mastics, and duct insulation. Specifically, the assessment found approximately 5,028 square feet of mastic containing asbestos (5% Chrysotile) associated with vinyl floor tiles, and an additional 600 square feet of mosaic vinyl floor sheeting with asbestos in its backing.

The survey recommends that prior to any disturbance activities, confirmed and assumed ACM should be abated or provided with appropriate response actions. The report suggests treating any unsampled suspect materials as potentially containing asbestos until proven otherwise. Additionally, the survey recommends submitting a notification to the Florida Department of Environmental Protection at least 10 days before renovation/demolition, in accordance with state and federal regulations. The assessment was conducted following Veterans Health Administration (VHA) Directive 7714 and complies with OSHA and EPA asbestos management regulations.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Baseline Asbestos Assessment Survey

Project Location: Building 500 – Main Clinic Lake Baldwin Orlando VA Medical Center 5201 Raymond Street, Orlando, FL 32083

Prepared for:

Rohan McKenzie and Robert Edwards Contracting Offcr. and Contracting Spc.

Department of Veterans Affairs Network Contracting Office 8 (NCO 8) Orlando VA Healthcare System 13800 Veterans Way, Orlando FL 32827

Prepared by:

Thunderbird-HRP JV, LLC 2500 S. Old Highway 94, Ste. 202 St. Charles, MO 63303

February 26, 2025

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500 i

TABLE OF CONTENTS

EXECUTIVE SUMMARY ........................................................................................................... II

1. INTRODUCTION

1.1. Purpose

1.2. Scope of Services

1.3. Project Limitations

2. ASBESTOS BULK SAMPLING

2.1. Sampling Methodology

2.2. Non-Suspect Material(s)

3. SITE PROVIDED INFORMATION

3.1. Previous Assessment Activities

4. FINDINGS AND CONCLUSIONS

5. RECOMMENDATIONS

6. SIGNATURE PAGE

7. REFERENCES

TABLES

Table 1 Suspect ACM Sampling Information

FIGURES

Figure 1 1st Floor Sampling Locations Figure 2 2nd Floor Sampling Locations Figure 3 3rd Floor Sampling Locations Figure 4 4th Floor Sampling Locations Figure 5 Mezzanine Sampling Locations

APPENDICES

Appendix A Laboratory Analytical Reports Appendix B Photograph Log of Homogenous Areas Appendix C Asbestos Inspector Licenses ii

EXECUTIVE SUMMARY

Baseline Asbestos Assessment Survey

Assessment Location: Lake Baldwin Orlando VA Medical Center: Building 500 – Main Clinic, located at

13800 Veterans Way, Orlando, Florida, 32083 (referred to herein as “the Site”)

Purpose of Assessment: The Veterans Health Administration (VHA) Directive 7714 (Asbestos

Management Program), dated April 6, 2017, calls for a survey following requirements of the Asbestos

Hazard Emergency Response Act (AHERA), known as a baseline survey. The purpose of the baseline survey is to identify, quantify, and sample suspect asbestos containing material (ACM) throughout the building. The survey was conducted in accordance with the Occupational Safety and Health

Administration (OSHA) and the Environmental Protection Agency (EPA) regulations. Non-suspect materials, which are defined as materials that are not expected to contain asbestos, were not sampled or analyzed as part of this survey.

Assessment Activities: The baseline survey for Building 500 was conducted on October 24th through

October 28th, 2024, by Thunderbird-HRP JV, LLC (Thunderbird-HRP) accredited asbestos inspectors. The survey included collecting representative samples of suspect asbestos-containing materials (ACMs), assessing their condition, and quantifying the materials and hazards present throughout the building.

Samples were submitted to Arrowhead Technologies, LLC, in Clearwater, Florida, a National Voluntary

Laboratory Accreditation Program accredited laboratory (NVLAP code 200703-0), for analysis of asbestos content by the Polarized Light Microscopy (PLM) method. A summary of suspect materials included in the asbestos survey, with those reported to be ACM (if applicable) indicated in bold, is included in Table 1.

Key Findings

As detailed in Table 1, the following is provided as a summary of materials containing asbestos:

The 1st floor of Building 500 contains multiple flooring materials and mastics reported to contain asbestos and are identified as ACM. Specifically, HA-34, HA-38, HA-54, HA-56, HA-106 and HA-144 have mastic containing asbestos (approximately 5,028 square feet) with the associated vinyl floor tile containing no asbestos. HA-55 is a mosaic pattern LinoleumTM-type vinyl floor sheeting containing asbestos in the backing (approximately 600 square feet). Refer to Table 1 and Figure 1 for detailed sample descriptions and ACM locations.

The previous Asbestos Survey report conducted by OHC Environmental Engineering, dated

September 29, 2014 identified asbestos in Red Duct Mastic and Sink Undercoating in addition iii to the flooring materials and mastics identified in this report. The Red Duct Mastic and Sink

Undercoating on the first floor should be assumed positive.

Recommendations

Recommendations resulting from the Baseline Asbestos Assessment Survey include the following:

Prior to disturbance activities, any confirmed and/or assumed ACM should be abated or provided with appropriate response actions. These materials are summarized above and within

Section 4.0 of this report.

Additionally, any other suspect material not included in this report should be treated as ACM, and should not be disturbed until sampled, tested, and proven otherwise.

1. INTRODUCTION

Thunderbird-HRP was retained by the Orlando VA Healthcare System to conduct a baseline asbestos assessment survey for the Lake Baldwin Orlando VA Medical Center, Building 500 – Main Clinic, located at 5201 Raymond Street, Orlando, FL 32083 (hereinafter referred to as “the Site”). This included inspecting suspect flooring, wall, ceiling, duct and piping systems located in all areas of Building 500 (crawl space, Mezzanine, and Floors 1 – 4). The specific locations included in the survey are detailed in Section 2.0.

1.1. Purpose

The Veterans Health Administration (VHA) Directive 7714 (Asbestos Management Program), dated April

6, 2017, calls for a survey following requirements of the Asbestos Hazard Emergency Response Act

(AHERA), known as a baseline survey. The purpose of the baseline survey is to identify, quantify, and sample suspect asbestos containing material (ACM) throughout the building. The survey was conducted in accordance with the Occupational Safety and Health Administration (OSHA) and the Environmental

Protection Agency (EPA) regulations. Non-suspect materials, which are defined as materials that are not expected to contain asbestos, were not sampled or analyzed as part of this survey.

1.2. Scope of Services

This baseline asbestos assessment survey was performed using general procedures and protocols appearing in EPA 40 CFR, part 763 (AHERA Protocols), and included the following general components: (1)

Site walkthrough; (2) Identification, classification, and bulk sample collection of suspect ACM; and (3) interpretation of laboratory analytical results. The scope of services provided by Thunderbird-HRP included the following tasks:

Review of applicable regulatory standards on asbestos and pre-demolition/renovation requirements;

Coordination with a NVLAP accredited laboratory for bulk sample analysis;

Walkthrough of all areas of interest with the Site representatives and review the scope of the project;

Identification, classification, quantification, delineation, and bulk sample collection of suspect ACM which is present within the building; and

Interpretation of laboratory PLM analytical reports.

No significant scope-of-work additions or modifications other than those noted below.

1.3. Project Limitations

The following areas were not inspected due to inaccessibility, or at the request of the site contact:

Roof / Roofing materials, Building Exterior

CT Scan Addition – Under Construction

Beneath concrete floors , D

Behind or inside concrete, masonry, cementitious, rigid, or CMU Walls or Parapets or CMU walls and cavities (loose fill insulation)

Confined Wall and floor utility chases, pipe chases and/or tunnels, inside/behind walls and wall cavities, pipe/utility trenches, etc vinyl/metal windows/casings (caulking & glazing)

Mirror Glue (in Restrooms)

Room 1720, 266 & 272, Clean Rooms – Above the ceiling and under the vinyl tile was not inspected.

If any additional materials other than those sampled and reported in this survey are identified within the building, they should be treated as asbestos-containing until proven otherwise via sampling and analysis in accordance with applicable regulations.

2. ASBESTOS BULK SAMPLING

The baseline survey for Building 500 was conducted on October 24th through October 28th, 2024, by

Thunderbird-HRP accredited asbestos inspectors. The survey included collecting representative samples of suspect asbestos-containing materials (ACMs), assessing their condition, and quantifying the materials and hazards present throughout the building.

2.1. Sampling Methodology

Thunderbird-HRP personnel systematically inspected the Site building as described above, and specified by the Site representatives. During the survey, Thunderbird-HRP classified each suspect ACM as one (1) of three (3) types:

Surfacing Materials - ACM sprayed or troweled on surfaces (walls, ceilings, structural members) for acoustical, decorative, or fireproofing purposes.

Thermal System Insulation (TSI) - Insulation used to inhibit heat transfer or prevent condensation on pipes, boilers, tanks, ducts, and various other components of hot and cold-water systems and heating, ventilation, and air conditioning (HVAC) systems. This includes pipe lagging, pipe wrap;

block, batt, and blanket insulation; cements and “muds”; and a variety of other products such as gaskets and ropes; or, Miscellaneous Material – Other, largely non-friable products and materials such as flooring, floor tile, ceiling tile, roofing felt, concrete pipe, outdoor siding, and fabrics.

Thunderbird-HRP inspectors touched all suspect materials to determine the extent to which the material, when dry, may be crumbled, pulverized, or reduced to powder by hand. During the survey, suspect materials identified by the inspector were also evaluated for overall condition, and each suspect material was assigned a condition of significantly damaged, damaged, or good overall condition for the locations the materials were observed. As defined by the US EPA under Asbestos Hazard Emergency Response Act

(AHERA), a material is significantly damaged if ten percent (10%) or greater of the material is evenly deteriorated, crumbling, hanging, or if the material contains over 25% localized damage. A damaged material is one that has less than 10% evenly distributed damage or less than 25% localized damage. A material in good condition is a material with no visible damage or deterioration or showing only very limited damage or deterioration.

Each suspect ACM was also classified into a homogeneous sampling area (HA). An HA is an area which is uniform in texture and appearance, was likely installed during the same period, and is unlikely to consist of more than one type or formulation of material. Thunderbird-HRP inspectors collected samples of each material from each HA, with multiple samples of a single material collected as appropriate. Samples were not collected from materials that were readily identifiable as non-asbestos containing (i.e., wood, fiberglass, foam, rubber, paper wraps, etc.) or previously confirmed to be asbestos containing (if applicable).

To avoid disturbing the material any more than necessary and to minimize any unnecessary release of potential asbestos fibers during collection, Thunderbird-HRP’s inspectors performed bulk sampling of suspect ACM in accordance with generally accepted procedures outlined in the US EPA document

"Guidance for Controlling Asbestos-Containing Materials in Buildings" (EPA-560/5-85-024, June 1985).

Each sample was collected using wet methods and placed in clean, sealable plastic bags and labeled with a unique sample identification number.

Bulk samples were submitted to Arrowhead Technologies, LLC, in Clearwater, Florida, a National Voluntary

Laboratory Accreditation Program accredited laboratory (NVLAP code 200703-0), for analysis of asbestos content by the Polarized Light Microscopy (PLM) method.

2.2. Non-Suspect Material(s)

Non-suspect materials, which are defined as materials that are not expected to contain asbestos, were not sampled or analyzed. Non-suspect materials typically include general building materials (e.g., glass, metals, brick, fiberglass, concrete, wood, cinderblock, and rubber). Please note that if a suspect material is later identified on-site and is not among those materials identified in this report, that material must be assumed to be asbestos containing until sampled and proven otherwise. Refer to Table 1 for Suspect ACM

Sampling Information.

3. SITE PROVIDED INFORMATION

During this assessment, Site contacts provided Thunderbird-HRP with access to individual areas of the building.

3.1. Previous Assessment Activities

Site contacts provided Thunderbird-HRP with the following ACM survey:

ASBESTOS NESHAP SURVEY, Orlando Veterans Administration Medical Center, Building 500, 5201

Raymond Street, Orlando, Florida conducted by OHC Environmental Engineering, dated

September 29, 2014

4. FINDINGS AND CONCLUSIONS

The 1st floor of Building 500 contains multiple flooring materials and mastics reported to contain asbestos and are identified as ACM. Specifically, HA-34, HA-38, HA-54, HA-56, HA-106 and HA-144 have mastic containing asbestos (approximately 5,028 square feet) with the associated vinyl floor tile containing no asbestos. HA-55 is a mosaic pattern vinyl floor sheeting containing asbestos in the backing (approximately 600 square feet). Refer to Table 1 and Figure 1 for detailed sample descriptions and ACM locations.

The previous Asbestos Survey report conducted by OHC Environmental Engineering, dated

September 29, 2014, identified asbestos in Red Duct Mastic and Sink Undercoatings in addition to the flooring materials and mastics identified in this report. The Red Duct Mastic and Sink

Undercoatings on the first floor should be assumed positive.

Figures depicting sample locations are provided in Figure 1 (1st Floor), Figure 2 (2nd Floor), Figure 3 (3rd

Floor), Figure 4 (4th Floor) and Figure 5 (Mezzanine). The complete asbestos laboratory analytical reports are provided in Appendix A. A photograph log depicting each homogeneous sampling area is provided in

Appendix B, and Thunderbird/HRP inspector’s license documentation is provided in Appendix C.

5. RECOMMENDATIONS

Based on the findings of the baseline asbestos assessment survey documented in this report, Thunderbird-

HRP recommend the following:

Prior to disturbance activities, any confirmed and/or assumed ACM should be abated or provided with appropriate response actions. These materials are summarized above and within Section 4.0 of this report.

Additionally, any other suspect material not included in this report should be treated as ACM, and should not be disturbed until sampled, tested, and proven otherwise.

In accordance with Federal and State of Florida rules, Thunderbird-HRP recommends that a notification and a copy of this report be submitted to the Florida Department of Environmental

Protection (FDEP) at least 10 days prior to the onset date of renovation/demolition. The FDEP prefers that the notification be delivered via email at the following web link:

o http://www.fldepportal.com/go/submit-registration/

Correspondence or questions may be addressed by the FDEP’s Central District office o Asbestos Program Director

Florida Department of Environmental Protection

Central District

3319 Maguire Boulevard

Suite No. 232

Orlando, Florida 32803 p: 407.897.4100

6. SIGNATURE PAGE

Thunderbird-HRP, with over 40 years of combined experience in environmental consulting, certifies that the baseline asbestos assessment survey documented in this report has been completed in accordance with the NESHAP and AHERA current regulations and requirements.

EPA

Accredited

Expiration.

Date

Signature Date

Survey Conducted and Report Written by:

Mr. Adam Marenholz

25-5606- 106-277914 1/3/26

2/26/25

Survey Conducted and Report Written by:

Mr. William Swain

25-5606- 106-503921 1/3/26

Survey Conducted and Report Written by:

Mr. Richard Cwiklowski, P.E.

Senior Project Manager

STC-

20240202-

003751ABIR

2/2/25

Signature Date

Report Reviewed by:

Mr. John Stump, PG, LAC Primary Qualifying Agent HRP Associates, Inc.

Asbestos Business Organization ZA473

Report Issued by:

Darby W. Hittle, L.E.P Thunderbird Environmental LLC.

President/Owner

Rick.Cwiklowski Placed Image

7. REFERENCES

Code of Federal Regulations Title 40, Chapter 1, Subpart C, Part 61, Subpart M (https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-61/subpart-M).

United States Environmental Protection Agency, Asbestos and School Buildings (https://www.epa.gov/asbestos/asbestos-and-school-buildings).

VHA Directive 7714, Asbestos Management Program, Department of Veterans Affairs, April 6, 2017.

TABLE(S)

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 1 of 9

TABLE 1: SUSPECT ACM SAMPLING INFORMATION (BUILDING 500)

HA #* Sample IDs Material Description Material Locations

Sample Locations Type, Condition Friable (Y/N)

Approx.

Quantity

ACM

(Y/N)

Asbestos Type

HA-1 HA-1- A,B,C,D,E White mastic (on duct insulation) 1st, 2nd, and

4th Floor

A – Room 403 (Group Room #1) B – Room 418 (office room) C – Room 440 (Server Room) D – Room 1807 E – Room 219

Misc., Good N _ N ND

HA-2 HA-2-A, B, C Yellow mastic (located beneath 12” x 12” Grey carpet)

4th Floor A – Room 403 (Group Room #1) B – Room 418 (office room) C – Room 442 (Teamwork Zone)

Misc., Good N

N ND

HA-3 HA-3-A, B, C, D 2’ x 2’ white lay-in ceiling tile 4th Floor

A – Room 403 (Group Room #1) B – Room 418 (office room) C – Room 424 (Restroom) D – Room 440 (Server Room)

Misc., Good N

N ND

HA-4 HA-4-A, B Grey mastic (on duct) 4th Floor A – Room 424 (Restroom) B – Room 457 (Restroom)

Misc., Good N

N ND

HA-5 HA-5-A, B, C

White drywall

4th Floor A – Room 424 (Restroom) B – Room 433 (Breakroom) C – Room 457 (Restroom)

Misc. Cat. 2, Good

Y

_ N ND

white joint compound N ND

HA-6 HA-6-A, B, C

Grey cove base

4th Floor A – Room 433 (Breakroom) B – Room 440 (Server Room) C – Room 467 (Storage Room)

Misc., Good N

_ N ND

Tan mastic N ND

HA-7 HA-7-A, B, C

2’ x 4’ tan vinyl tile w/ grey streaks

4th Floor A – Room 433 (Breakroom) B – Room 467 (Storage Room) C – Checkout Area (409)

Misc., Good N

_ N ND

Grey mastic N ND

HA-8 HA-8-A,B,C,D,F

Red mastic (located on piping in plenum space / walls) 1st, 3rd & 4th

Floor

A – Public Corridor (408) B – Room 333 (IT Room) C – Room 333 (IT Room) D – Room 1807 (Stairwell) F – Room 1121 (Utility Closet)

Misc., Good N

_ N ND

HA-9 HA-9-A,B,C

White drywall

3rd Floor A – Room 305 (Group Room #2B) B – Room 303 (Group Room #1B) C – Room 314 (Restroom)

Misc. Cat. 2, Good

Y

_ N ND

White joint compound N ND

HA-10 HA-10-A,B,C White mastic (on duct insulation) 3rd Floor A – Room 305 (Group Room #2B) B – Room 303 (Group Room #1B) C – Room 314 (Restroom)

Misc., Good N

N ND

HA-11 HA-11-A,B,C

Yellow mastic

(located beneath 12” x 12” blue carpet) 3rd Floor A – Room 305 (Group Room #2B) B – Room 303 (Group Room #1B) C – Room 339 (Office 44)

Misc., Good N

N ND

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 2 of 9

HA #* Sample IDs Material Description Material Locations Sample Locations

Type, Condition

Friable (Y/N)

Approx.

Quantity

ACM

(Y/N) Asbestos Type

HA-12 HA-12-A,B,C 2’ x 2’ white in-lay ceiling tile 3rd Floor A – Room 305 (Group Room #2B) B – Rm 303 (Group Room #1B) C – Room 314 (Restroom)

Misc., Good Y

N ND

HA-13 HA-13-A,B,C Grey mastic on duct 3rd Floor A – Room 314 (restroom) B – Room 330 (Restroom) C – Room 306 (Restroom)

Misc., Good N

N ND

HA-14 HA-14-A,B,C,D Pinkish red fire caulk 3rd and 1st

Floor

A – Room 333 (IT Room) B – Room 333 (IT Room) C – Room 333 (IT Room) D – Room 1715 (Prep Area)

Misc., Good N

HA-15 HA-15-A Green mastic (located around PVC piping) 3rd Floor A – Room 333 (IT Room) Misc., Good N _ N ND

HA-16 HA-16-A,B,C

Grey cove base

3rd Floor A – Room 331 (Breakroom) B – Room 339 (Office 44) C – Room 375 (Mail Room)

Misc., Good N

_ N ND

Tan mastic N ND

HA-17 HA-17-A,B

2’ x 2’ tan, grey streaked vinyl floor tile

3rd Floor A – Room 331 (Breakroom) B – Room 375 (Mailroom)

Misc., Good N

_ N ND

grey mastic N ND

HA-18 HA-18-A Off-white mastic on air duct insulation Mezzanine A – mezzanine air duct insulation Misc., Good N _ N ND

HA-19 HA-19-A,B,C White mastic Mezzanine A,B,C – mezzanine air duct insulation Misc., Good N _ N ND

HA-20 HA-20-A,B,C Grey mastic Mezzanine A,B,C – mezzanine air duct insulation Misc., Good N _ N ND

HA-21 HA-21-A,B,C Dark grey mastic Mezzanine A,B,C – located on corner of air handling Unit 11 Misc., Good N

N ND

HA-22 HA-22-A,B Red mastic Mezzanine A,B – located around PVC piping through floor

Misc., Good N

N ND

HA-23 HA-23-A

White drywall

Mezzanine A – mezzanine western wall Misc. Cat. 2, Good Y

_ N ND

White joint compound N ND

HA-24 HA-24-A,B,C White mastic on air duct insulation 1st Floor (VBA) A – Room 1215 (Office 3) B – Room 1015 (Office 16) C – Room 1017 (File Room)

Misc., Good N

N ND

HA-25 HA-25-A,B,C 2’ x 2’ white, smooth in-lay ceiling tile 1st Floor (VBA) A – Room 1215 (Office 3) B – Room 1015 (Office 16) C – Room 1017 (File Room)

Misc., Good N

N ND

HA-26 HA-26-A,B,C

Clear mastic

(Located beneath grey/cracked blue carpet and black rubber backing)

1st Floor (VBA) A – Room 1215 (Office 3) B – Room 1015 (Office 16) C – Room 1032 (Conference Room)

Misc., Good N

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 3 of 9

HA #* Sample IDs Material Description Material Locations Sample Locations

Type, Condition

Friable (Y/N)

Approx.

Quantity

ACM

(Y/N) Asbestos Type

HA-27 HA-27-A,B,C

Off-white drywall

1st Floor (VBA) A – Room 1215 (Office 3) B – Room 1015 (Office 16) C – Room 1017 (File Room)

Misc. Cat. 2, Good Y

_ N ND

White joint compound N ND

HA-28 HA-28-A,B,C

Grey cove base

1st Floor (VBA) A – Room 1215 (Office 3) B – Room 1015 (Office 16) C – Room 1017 (File Room)

Misc., Good N

_ N ND

Clear / grey mastic N ND

HA-29 HA-29-A,B,C,D Red fire caulk 1st Floor (VBA) A,B,C – Room 1017 (File Room; on wall above plenum space) D – Hallway outside Room 1600A

Misc., Good N

N ND

HA-30 HA-30-A,B,C

3’ x 3’ grey splotched vinyl floor tile

1st Floor (VBA) A – Room 1017 (File Room) B,C – Room 1056 (Breakroom)

Misc., Good N

_ N ND

Red mastic N ND

HA-31 HA-31-A,B,C

Brown laminate plank flooring

1st Floor (VBA) A – Room 1048 (Copier Area) B – Room 1044C (Office Cubicle) C – Corridor 1002 (by swing doors)

Misc., Good N

_ N ND

Red mastic N ND

HA-32 HA-32-A,B,C Clear mastic (under dark grey carpet with purple cracks design)

1st Floor (VBA) A – Room 1044B (Office Cubicle) B – Room 1044C (Office Cubicle) C – Room 1044E (Office Cubicle)

Misc., Good N _ N ND

HA-33 HA-33-A,B,C,D 2’ x 2’ white fissured ceiling tile 1st Floor (Store)

A – Room 1815 (Storage Room) B – Room 1815A (Storage Room) C – Room 1815A (Storage Room) D – Room 1516A

Misc., Good Y _ N ND

HA-34 HA-34-A,B,C,D,E

12” x 12” white w/ grey marble vinyl floor tile

1st Floor

A – Room 1815 (Storage Room) B – Room 1815 (Storage Room) C – Room 1815 (Storage Room) D – Room 1127 (Exam Room) E – Room 1123B

Misc., Good N 2,000 SF

N ND

Black mastic Y 5% Chrysotile

HA-35 HA-35-A,B,C,D

White drywall

1st Floor A,B,C – Room 1815A (Storage Room) D – Hallway outside Room 1600A

Misc. Cat. 2, Good Y _

N ND

White joint compound N ND

HA-36 HA-36-A,B,C Red fire caulk 1st Floor (Store)

A – Room 1815 (Storage Room) B – Room 1815 (Storage Room) C – Room 1815A (Storage Room)

Misc., Good N _ N ND

HA-37 HA-37-A,B,C

12” x 12” white vinyl floor tile 1st Floor

(Store) A,B,C – Room 1815A (Storage Room) Misc., Good N _

N ND

Yellow mastic N ND

HA-38 HA-38-A,B,C

12” x 12” white vinyl floor tile (beneath HA-37)

1st Floor A,B – Room 1815A (Storage Room) C – Room 1516A Misc., Good N 2,000 SF black mastic Y 5% Chrysotile

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 4 of 9

HA #* Sample IDs Material Description Material Locations Sample Locations

Type, Condition

Friable (Y/N)

Approx.

Quantity

ACM

(Y/N) Asbestos Type

HA-39 HA-39-A,B,C

Grey cove base 1st Floor

(Store)

A – Room 1815A (Storage Room) B – Room 1815A (Storage Room) C – Room 1815 (Storage Room)

Misc., Good N _

N ND

Tan mastic N ND

HA-40 HA-40-A,B,C

Brown “wood” plank laminate flooring 1st Floor

(Store) A,B,C – Room 1708 (Store) Misc., Good N _

N ND

Yellow/black mastic N ND

HA-41 HA-41-A,B,C,D 2’ x 2’ white smooth in-lay ceiling tile 1st Floor A,B,C – Room 1711C (Dining Room) D – Hallway outside Room 1600A Misc., Good Y _ N ND

HA-42 HA-42-A,B,C

Beige cove base 1st Floor

(Dining Room) A,B,C – Room 1711C (Dining Room) Misc., Good N _ N ND

Yellow mastic

HA-43 HA-43-A,B,C,D,E,F White mastic on duct insulation 1st Floor

A,B,C – Room 1711C (Dining Room) D – Storage Room (Pharmacy) E – Room 1340C F – Room 142 (IT Room)

Misc., Good N _ N ND

HA-44 HA-44-A,B,C,D,E,F

White drywall

1st Floor

A,B,C – Room 1711C (Dining Room) D – Room 1340C E – Room 1801B F – Room 1704

Misc. Cat. 2, Good Y _ N ND

White joint compound

HA-45 HA-45-A,B,C Grey mastic on duct 1st Floor

(Dining Room) A,B,C – Mechanical Room within Dining Room (1711C)

Misc., Good N _ N ND

HA-46 HA-46-A,B,C,D,E 2’ x 2’ white fissured ceiling tile 1st Floor

(Dining Room)

A,B,C – Room 1711C (Dining Room) D – Room 1801B E – Room 1704

Misc., Good N _ N ND

HA-47 HA-47-A,B,C 2’ x 2’ white vinyl ceiling tile 1st Floor A – Room 1728 B – Room 1807 (Stairwell) C – Room 1817 (Storage)

Misc., Good N _ N ND

HA-48 HA-48-A Tan mastic on duct insulation 1st Floor A – Room 1728 Misc., Good N _ N ND

HA-49 HA-49-A,B,C,D,E,F

White drywall

1st Floor

A – Room 1728 B – Room 1827 C – Room 1827 D – Room 1715 (Prep Area) E – Room 1715 (Beverages Area) F – Room 1309J

Misc. Cat. 2, Good

Y _

N ND

White/grey joint compound N ND

HA-50 HA-50-A

12” x 12” white vinyl floor tile

1st Floor A – Room 1728

Misc., Good N _

Yellow mastic N ND

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 5 of 9

HA #* Sample IDs Material Description Material Locations

Sample Locations Type, Condition Friable (Y/N)

Approx.

Quantity

ACM

(Y/N)

Asbestos Type

HA-51 HA-51-A,B,C

Black cove base

1st Floor A – Room 1728 B – Room 1720C (Women’s Locker) C – Room 1827

Misc., Good N _

N ND

Clear/tan mastic N ND

HA-52 HA-52-A,B,C,D,E 2’ x 2’ white fissured (older) ceiling tile 1st Floor

(Dining Room)

A – Room 1727 B,C – Room 1827 D – Room 1715 (Prep Area) E – Room 1309J

Misc., Good Y

HA-53 HA-53-A

Tan cove base

1st Floor A – Room 1727 Misc., Good N _

N ND

Yellow mastic N ND

HA-54 HA-54-A,B,C

Yellow mastic (located beneath 2’ x 2’ green carpet – black backing)

1st Floor A – Room 1727 B – Room 1720C (Women’s Locker) C – Room 1827

Misc., Good N 800 SF

N ND

12” x 12” white vinyl floor tile N ND Black mastic Y 3% Chrysotile

HA-55 HA-55-A,B,C,D

HA-55-A,B only: yellow mastic (located beneath 12” x 12” green carpet – black backing)

1st Floor A,B – Room 1727A C – 1720CA (Restroom) D – Room 1118

Misc., Good N 600 SF

N ND

Mosaic white/tan vinyl floor sheeting Y 30% Chrysotile Yellow mastic N ND

HA-56 HA-56-A

Yellow mastic (located beneath green carpet)

1st Floor A – Room 1727B Misc., Good N 120 SF

N ND

12” x 12” grey vinyl floor tile N ND Brown mastic Y 5% Chrysotile

HA-57 HA-57-A,B,C

Light brown faux wood linoleum planking

1st Floor A – 1721 Loading Dock Hallway B – 1721 Loading Dock Hallway C – 1721 Hallway (outside Canteen)

Misc., Good N _

N ND

Yellow mastic N ND

HA-58 HA-58-A,B

Dark grey cove base

1st Floor A – Room 1712 (Canteen Office) B – Room 1715B

Misc., Good N _

N ND

Tan mastic N ND

HA-59 HA-59-A,B,C

12” x 12” white vinyl tile (located under HA-60)

1st Floor A – Room 1712 (Canteen Office) B – Room 1715B C – Room 1715A

Misc., Good N _

N ND

Yellow mastic N ND Grey levelling compound N ND

HA-60 HA-60-A,B,C

12” x 12” grey streaked linoleum tile

1st Floor A – Room 1712 (Canteen Office) B – Room 1621 (Admin Office) Misc., Good N _

N ND

Clear / yellow mastic N ND

HA-61 HA-61-A,B,C

Black, tall cove base

1st Floor A – Room 1715 (Chef Area) B – Room 1715C C – Room 1715M

Misc., Good N _

N ND

Yellow mastic N ND

HA-62 HA-62-A 2’ x 4’ grey splotched linoleum tile 1st Floor A – Room 1715B Misc., Good N _ N ND

HA-63 HA-63-A,B,C

Tan cove base

1st Floor A – Room 1715B B – Room 1715B C – Room 1715B

Misc., Good N _

White mastic N ND

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 6 of 9

HA #* Sample IDs Material Description Material Locations

Sample Locations Type, Condition

Friable (Y/N)

Approx.

Quantity

ACM

(Y/N)

Asbestos Type

HA-64 HA-64-A,B,C Tan mastic under wall vinyl sheeting 1st Floor A,B,C – Room 1715 (Paper Goods Storage) Misc., Good N _ N ND

HA-65 HA-65-A,B

12” x 12” white vinyl floor tile (thin)

1st Floor A,B – Room 1715R Misc., Good N _

N ND

Grey mastic N ND

HA-66 HA-66-A,B,C

White drywall

1st Floor A – Room 1602 (Classroom) B – Room 1612A (Copy Room) C – Room 1621

Misc. Cat. 2, Good

N _

N ND

white joint compound N ND

HA-67 HA-67-A,B,C

Grey cove base (tall)

1st Floor A – Room 1601 B – Room 1620 (Board Room) C – Room 1611

Misc., Good N _

N ND

Yellow mastic N ND

HA-68 HA-68-A

White leveling compound (located beneath red/blue carpet) 1st Floor A – Room 1621A (Copy Room) Misc., Good N _ N ND

HA-69 HA-69-A Yellow mastic (located beneath red/blue carpet) 1st Floor A – Room 1621A (Copy Room) Misc., Good N _ N ND

HA-70 HA-70-A,B,C,D,E,F Yellow mastic (located beneath 2’ x 2’ blue and white lined carpet)

1st Floor

A – Room1622 (VAM Room) B – Room 1620 (Board Room) C – Room 1617 (Offices) D – Room 1801B E – Room 1704 F – Room 1703

Misc., Good N _ N ND

HA-71 HA-71-A,B,C

Grey cove base (short)

1st Floor A – Room 1607C B – Room 1704 C – Room 1704

Misc., Good N _

N ND

Tan mastic N ND

HA-72 HA-72-A,B,C

Tan cove base

1st Floor A – Room 1616 B – Room 1607 C – Room 1607

Misc., Good N _

N ND

Yellow mastic N ND

HA-73 HA-73-A

Brown plank linoleum flooring

1st Floor A – Room 1607C (HAS Supervisor) Misc., Good N _ N ND Yellow mastic

HA-74 HA-74-A

2’ x 4’ off-white vinyl tile

1st Floor A – Room 1611 (Office) Misc., Good N _

N ND

Yellow mastic N ND

HA-75 HA-75-A,B,C 2’ x 2’ white in-lay ceiling tile 1st Floor A – Room 1802 (interview Room) B – Room 1806 C – Room 1807

Misc., Good N _ N ND

HA-76 HA-76-A,B,C,D

White drywall

1st Floor

A – Room 1802 B – Room 1806 C – Room 1807 D – Pharmacy Storage Room

Misc. Cat. 2, Good Y _

White joint compound N ND

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 7 of 9

HA #* Sample IDs Material Description Material Locations

Sample Locations Type, Condition Friable (Y/N)

Approx.

Quantity

ACM

(Y/N)

Asbestos Type

HA-77 HA-77-A,B,C

2’ x 2’ grey streaked vinyl floor tile

1st Floor A – Room 1802 B – Room 1806 C – Room 1810 (Kitchen Fridge)

Misc., Good N _

N ND

Yellow mastic N ND

HA-78 HA-78-A,B,C

Grey cove base (tall)

1st Floor A – Room 1802 B – Room 1806 C – Room 1807 (Stairwell)

Misc., Good N _

N ND

Tan mastic N ND

HA-79 HA-79-A,B,C

Grey mastic (located under grey carpet with orange lines)

1st Floor A – Room 1807 (Comm. Field Staff) B – Room 1812A C – Room 1814A

Misc., Good N _

N ND

Grey leveling compound N ND

HA-80 HA-80-A,B,C

Light grey linoleum floor sheeting

1st Floor A – Room 1807 (Stairwell) B – Room 1807 (Stairwell) C – Room 112

Misc., Good N _

N ND

Yellow mastic N ND

HA-81 HA-81-A,B,C

3’ x 3’ white with black swirled vinyl floor tile

1st Floor A – Room 1817/1824 (MSD Storage) B – Room 1817/1824 (MSD Storage) C – Room 1126 (Emerg. Treatment)

Misc., Good N _

N ND

Yellow mastic N ND

HA-82 HA-82-A,B,C,D

Greyish/pink cove base

1st Floor A – Room 117 (Lounge) B – Room 118 (Restroom) C – Room 120

Misc., Good N _

N ND

Yellow mastic N ND

HA-83 HA-83-A,B,C

12” X 12” white, grey speckled vinyl floor tile

1st Floor A – Room 117 B – Room 118 C – Area outside Pharmacy Workroom

Misc., Good N _

N ND

Yellow mastic N ND

HA-84 HA-84-A,B,C

Brown vinyl plank flooring 1st and 2nd

Floor

A – Room 120 B – Room 120 C – Room 260

Misc., Good N _

N ND

Clear/yellow mastic N ND

HA-85 HA-85-A

2’ x 2’ tan, white brushed vinyl tile 1st Floor

(Pharmacy) A – Pharmacy Storage Room Misc., Good N _

N ND

Yellow mastic N ND

HA-86 HA-86-A

Clear mastic (located beneath grey and tan carpet) 1st Floor

(Pharmacy) A – Pharmacy Workroom Misc., Good N _ N ND

HA-100 HA-100-A,B,C,D

Vinyl blue, white, and black floor sheeting

1st Floor A,B – Room 1340C (Physical Therapy) C,D – Room 1213D

Misc., Good N _

N ND

Pinkish red mastic N ND

HA-101 HA-101-A,B,C,D

Tan with grey textured floor coating

1st Floor

A – Room 1213J B – Room 1213F C – Room 1214C D – Room 1430

Misc., Good N _ N

ND

Tan Mastic ND

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 8 of 9

HA #* Sample IDs Material Description Material Locations

Sample Locations Type, Condition Friable (Y/N)

Approx.

Quantity

ACM

(Y/N)

Asbestos Type

HA-102 HA-102-A,B,C

Teal carpet mastic (located beneath grey/white carpet with black backing) 1st Floor A,B – Room 1214 C – Room 1304B Misc., Good N _ N ND

HA-103 HA-103-A,B,C,D

12” x 12” white speckled vinyl floor tile

1st Floor

A – Room 1309E B – Room 1309D C – Room 1309H D – Room 1113 (Kitchen)

Misc., Good N _

N ND

Yellow mastic N ND

HA-104 HA-104-A,B,C

Blue cove base

1st Floor A,B,C – Room 1309D Misc., Good N _

N ND

Yellow mastic N ND

HA-105 HA-105-A,B Black dental lab countertop 1st Floor A,B – Room 1306C (Dental Lab) Misc., Good N _ N ND

HA-106 HA-106-A,B,C

12” x 12” older white vinyl floor tile

1st Floor A,B,C – Room 1306 (HVAC Closet) Misc., Good N 8 SF

N ND

Black mastic Y 5% Chrysotile

HA-107 HA-107-A

Black cove base

1st Floor A – Room 1306 Misc., Good N _

N ND

Brown mastic N ND

HA-108 HA-108-A,B,C

1’ X 2’ grey streaked vinyl floor tile

1st Floor A – Room 1604 B – Room 1604A C – Room 1604C

Misc., Good N _

N ND

Greyish/yellow mastic N ND

HA-109 HA-109-A,B,C 2’ x 2’ white acoustic ceiling tile 1st Floor A,B,C – Room 1604 Misc., Good N _ N ND

HA-110 HA-110-A,B,C

3’ x 4’ grey brushed vinyl floor tile

1st Floor A,B,C – Room 1606 (Police Locker Room)

Misc., Good N _

N ND

Yellow mastic N ND

HA-111 HA-111-A,B,C,D

Blue vinyl floor sheeting (grey stencils)

1st Floor A,B,C – Room 1121 (Reception) D – Room 1459

Misc., Good N _

N ND

Grey mastic N ND

HA-112 HA-112-A,B

Grey laminate flooring

1st Floor A,B – Room 1097 (Xray Room) Misc., Good N _ N ND Yellow mastic

HA-113 HA-113-A,B,C

White laminate flooring

1st Floor A – Room 1097 (Xray Room) B – Room 1100 C – Room 1097

Misc., Good N _ N ND Yellow mastic

HA-114 HA-114-A,B

12” x 12” dark grey vinyl floor tile

1st Floor A,B – Room 1100 Misc., Good N _

N ND

Yellow mastic N ND

HA-115 HA-115-A,B,C

0.5’ x 2.5’ grey vinyl plank flooring

1st Floor A,B,C – Room 1076 (Radiology Reception)

Misc., Good N _

N ND

Orange mastic N ND

HA-116 HA-116-A,B,C

Brown/grey vinyl floor sheeting

1st Floor A,B – Room 125 C – Hallway outside Room 121

Misc., Good N _

N ND

Green/yellow mastic N ND

HA-117 HA-117-A,B,C

Grey speckled vinyl sheeting

2nd Floor A – Room 229L B – Room 229M C – Room 228

Misc., Good N _

Grey mastic N ND

Baseline Asbestos Assessment Survey Orlando VA Medical Center: BLD 500

Table 9 of 9

HA #* Sample IDs Material Description Material Locations

Sample Locations Type, Condition Friable (Y/N)

Approx.

Quantity

ACM

(Y/N)

Asbestos Type

HA-118 HA-118-A,B,C

2’ x 2’ tan streaked vinyl floor tile

2nd Floor A – Room 203C B – Room 205 C – Room 201

Misc., Good N _

N ND

Yellow/grey mastic N ND

HA-119 HA-119-A,B,C 2’ x 4’ white ceiling tile 2nd Floor A,B,C – Room 219 Misc., Good Y _ N ND

HA-120 HA-120-A,B,C

White drywall

2nd Floor A – Room 219 B – Room 205 C – Hallway outside Room 217

Misc. Cat. 2, Good N _

N ND

White joint compound N ND

HA-121 HA-121-A,B,C

Off-white streaked vinyl floor sheeting

2nd Floor A – Room 210 B – Room 209A C – Room 217

Misc., Good N _ N ND Grey mastic

Grey leveling compound Yellow mastic

HA-127 HA-127-A Black epoxy flooring 1st Floor A – Room 1510 Misc., Good N _ N ND

HA-128 HA-128-A,B,C

Yellow carpet mastic (located beneath grey camo and grey carpets) 1st Floor

A – Room 1495 (Office) B – Room 1460 C – Room 1453

Misc., Good N _ N ND

HA-129 HA-129-A,B,C 2’ x 2’ white ceiling tile 1st Floor A – Room 1438 B – Room 1451 C – Corridor E105

Misc., Good Y _ N ND

HA-142 HA-142-A,B,C Grey fireproofing Spray-Applied Crawl Space A,B,C – crawl space on ceiling Surfacing, Good N _ N ND

HA-143 HA-143-A,B,C Tan mastic on piping Crawl Space A,B,C – crawl space on piping Misc., Good N _ N ND

HA-144 HA-144-A,B,C

White carpet mastic (beneath grey, white carpet)

1st Floor A,B,C – Room 1703A Misc., Good N 100 SF

N ND

12” x 12” white, grey speckled floor tile N ND Black/yellow mastic Y 2% Chrysotile

Homogeneous sampling areas identified in this table are based on information observed at the site. Material locations and total quantities for each suspect material were estimated at the discretion of the survey inspector(s) based on only observations during the survey. These should not be construed with total locations/quantities for the site building. Quantities and locations of underlying materials such as mastics should also be confirmed at the time of abatement due to difficulty with field confirmation as estimates are based on only those locations sampled during the inspection.

*Homogeneous areas 87-99, 122-126, and 130-141 are not included in this report as they pertain to other buildings on-site.

Bold: Signifies asbestos detected >1% ND: No Asbestos Content Detected

FIGURES

OVERALL FLOOR PLAN - BUILDING 500 - FLOOR: 01

SCALE: 3/128"=1'-0"

FD

FD

FD

FD

FD

FD

FD

FD

FD

FD FD FD FD

FD

FD

FD

FD

FD

FD

FD

FD

DRAW

DRAW

DRAW

DRAW

DRAW

PHLEBOLOMY

SUP CLOSET

M TLT

W TLT

M TLT

W TLT

STAFF TLT

CLEAN

STAFF

LACACTION

ROOM

PROCESSING

SUPPLY CLOSET

STAFF

ENTRY/EXIT

SPECIMAN

PROCESS

FRONT DESK/

SPEC LOG-IN

LC

KR

LO

C

KE

R

S

DRAW

BARIC DRAW

TLT M

TLT W

BREAK ROOM

RECLINED DRAW

DRAW

VOLUNTEER INFO

CENTER

FR

ID

G E

LO

C

KE

R

S

ERG International

1999/XC

ERG International

ERG International

TV

TV

1208 ERG International

362P ERG International

ERG International

1208 ERG International

ERG International

COR2460 ERG International

COR2460 ERG International

DN

REF.

DN

BREAKROOM

OPEN OFFICE

INTERVIEW 1812A

INTERVIEW

1802A

INTERVIEW

1802 IT

PROGRAM

SUPERVISOR

PROGRAM

SUPERVISOR

OUTREACH

STORAGE

1814E

UNISEX

ELEC

1802E

ELEC

1802D

WORK AREA

1807A WORK AREA

1814A

NE LOADING

DOCK

WAITING

1800A

RECEPTION

STAFF ENTRY

1807B

STAFF ENTRY

1807C

CLOSET

1814C

UNISEX

COMMUNITY/FIELD

STAFF

COMMUNITY/FIELD

STAFF

1814G

PROGRAM

SUPERVISOR

SUPPLY

PROGRAM

MANAGER

UNDER CONSTRUCTION

HA-83-C

HA-86-A

HA-76-D,

HA-43-D

HA-80-C

HA-84-B

HA-83-A

HA-82-A,

HA-84-D

HA-128-C

HA-29-B

HA-127-A HA-67-A,

HA-74-A

HA-70-C

HA-37-D,

HA-38-C,

HA-33-D

100-ABC

108-C

HA-71-A

HA-68-A,

HA-69-A

HA-24-A

HA-25-A

HA-26-A

HA-27-A

HA-28-A

HA-28-C

HA-24-C

HA-25-C

HA-27-C

HA-29-ABC

HA-24-B

HA-25-B

HA-26-B

HA-27-B

HA-28-B

HA-30-A

HA-30-B

HA-30-C

HA-31-A

HA-32-A

HA-32-B

HA-32-C

HA-31-B HA-31-C

HA-115-A

HA-115-B

HA-115-C

HA-128-B

HA-128-A

HA-129-A HA-116-B

HA-116-A

HA-116-C

HA-34-F

109-ABC

HA-35-D

HA-44-D

HA-29-B HA-109-A

HA-108-A HA-67-A

HA-66-A

HA-70-A

HA-66-C

HA-70-B

HA-67-B

HA-41-A

HA-42-B

HA-45-A,B,C

HA-41-B

HA-43-C

HA-49-A,B,C

HA-44-F

HA-46-F

HA-70-E

HA-42-A

HA-46-A

HA-59-A

HA-52D

HA-49-E

HA-14-D

HA-40-C

HA-70-D

HA-46-D

HA-40-A

HA-48-B

HA-75-A

HA-76-A

HA-77-A

HA-78-A HA-75-B

HA-76-B

HA-77-B

HA-78-B

HA-79-A

HA-1-D

HA-75-C

HA-76-C

HA-78-C

HA-80-A

HA-47-B

HA-80-B

HA-8-D

HA-79-B

HA-77-C

HA-81-A

HA-81-B

HA-79-C

HA-47-C

HA-54-C

HA-51-C

HA-49-B

HA-52-B

HA-52-C

HA-49-C

HA-50-C

HA-52-A

HA-48-A

HA-49-A

HA-57-A

HA-55-C HA-55-A

HA-56-A

HA-54-B

HA-51-B

HA-57-A,B

HA-65-A,B

HA-61-C

HA-64-B

HA-63-A,B,C

HA-59-C

HA-58-BHA-61-A

HA-58-A

HA-49-D

HA-60-A

HA-111-C

HA-111-A

HA-111-B

HA-34-E

HA-55-D

HA-113-C

HA-113-A

HA-112-A

HA-112-B

HA-113-B

HA-81-C

HA-34-D

HA-103-D

HA-114-A,B

HA-102-C

HA-102-C

C.T.-41(HA)

HA-102-B

HA-100-C

HA-43-E

HA-44-D

HA-52-E

HA-49-F

HA-100-C,D

HA-100-A

HA-100-B

HA-101-A

HA-107-A

HA-106-A,B,C

HA-105-A,B

HA-101-B

HA-103-C

HA-103-A

HA-104-A

HA-103-B

HA-104-B

HA-104-C

Veterans Health Administration

Drawing Title Project Title

Location

Date Checked Drawn

Building Number Project Number

Drawing Number

Drawing #

U.S. DEPARTMENT OF VETERANS AFFAIRS

ORLANDO VA HEALTH CARE SYSTEMS

FACILITIES & ENGINEERING SERVICE BOB 1 of 5

BUILDING 500

02/26/2025

ASBESTOS SAMPLE LOCATIONS

BASELINE ASBESTOS SURVEY

FLOOR 01

36C24824D0112

LAKE BALDWIN BUILDING 500, MAIN CLINIC

VHAORLLuna-D Rectangle

HA-84-C

HA-119-A,B,C

HA-120-A

HA-1-E

HA-118-B

HA-117-B

HA-117-A

HA-118-A

HA-117-CHA-118-C

HA-120-B

HA-121-CHA-121-A

HA-121-B

Veterans Health Administration

Drawing Title Project Title

Location

Date Checked Drawn

Building Number Project Number

Drawing Number

Drawing #

U.S. DEPARTMENT OF VETERANS AFFAIRS

ORLANDO VA HEALTH CARE SYSTEMS

FACILITIES & ENGINEERING SERVICE BOB 2 of 5

BUILDING 500

02/26/2025

BUILDING 500- FLOOR 2

SCALE 1/32" = 1'-0"

ASBESTOS SAMPLE LOCATIONS

BASELINE ASBESTOS SURVEY

FLOOR 02

36C24824D0112

LAKE BALDWIN BUILDING 500, MAIN CLINIC

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

CHECK-IN

GROUP ROOM

#2A

JAN

BREAKROOM

WORK AREA

REST

REST

REST

ELECT

STG

343 STORAGE

DATA

ELECT

REST

REST

MED TREATM

MAIL

STORAGE

TRIAGE

OFFICE 26

OFFICE 27

OFFICE 28

OFFICE 29

OFFICE 30

OFFICE 31

GROUP ROOM

#1A

OFFICE 32

OFFICE 33

OFFICE 34

OFFICE 35

OFFICE 36

OFFICE 25

OFFICE 24

OFFICE 23

OFFICE 22

OFFICE 21

OFFICE 20

OFFICE 13

OFFICE 14

OFFICE 15

OFFICE 16

OFFICE 17

OFFICE 18

OFFICE 19

OFFICE 12

OFFICE 11

OFFICE 10

OFFICE 9

OFFICE 8

OFFICE 7

OFFICE 6

OFFICE 5

OFFICE 4

OFFICE 3

OFFICE 2

OFFICE 1

RESTROOM

WAITING

OVERFLOW

WAITING

CHECK-OUT

STG

OFFICE 37

OFFICE 38

OFFICE 40

OFFICE 39

OFFICE 41

OFFICE 42

OFFICE 43

OFFICE 44

OFFICE 45

OFFICE 46

OFFICE 48

OFFICE 47

OFFICE 49

OFFICE 50

SHAFT

SHAFT

SHAFT

SHAFT

SHAFT

SHAFT

82 180

180 82

FE

FE

FE

GROUP ROOM

#2B

GROUP ROOM

#1B

HA-11-A

HA-10-A

HA-9-A

HA-12-A HA-13-C

HA-16-C

HA-17-B

HA-9-B

HA-10-B

HA-12-B

HA-11-B

HA-13-A

HA-10-C

HA-9-C

HA-12-C

HA-16-B HA-11-C

HA-16-A

HA-17-A

HA-13-B

HA-14-A,B,C HA-8-B,C

HA-15-A

RED MASTIC ON

DUCTS UNDER

INSULATION

Veterans Health Administration

Drawing Title Project Title

Location

Date Checked Drawn

Building Number Project Number

Drawing Number

Drawing #

U.S. DEPARTMENT OF VETERANS AFFAIRS

ORLANDO VA HEALTH CARE SYSTEMS

FACILITIES & ENGINEERING SERVICE BOB 3 of 5

BUILDING 500

02/26/2025

BUILDING 500- FLOOR 3

SCALE 1/16" = 1'-0"

ASBESTOS SAMPLE LOCATIONS

BASELINE ASBESTOS SURVEY

FLOOR 03

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

2 2 2

WAITING #1

WAITING #2

CHECK-IN

407 CHECK-OUT

NURSE TRIAGE

JAN

OFFICE 1

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

OFFICE 6

OFFICE 1

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

BREAKROOM

WORK AREA

REST

OFFICE 6

NEUROP

RECORDS

POD

REST

INTERV ROOM 2

INTERV ROOM 1

EDU/ADM POD

REST

ELEC

STG

444 STORAGE

DATA

ELEC

OFFICE 15

REST 468

OFFICE 14

OFFICE 13

OFFICE 12

REST

VOC REHAB OFF

INTERV ROOM 3

POD

REST

MAIL

OBS REST

OFFICE 1

OFFICE 2

OFFICE 3

OFFICE 4

OFFICE 5

OFFICE 6

OFFICE 7

OFFICE 8

OFFICE 9

OFFICE 10

OFFICE 11

STORAGE

SUB-WAITING

GROUP ROOM #1

TEAMWORK

ZONE VOC

REHAB

TEAMWORK

ZONE EXTRA

STG

PTSD OPEN

WORK AREA

OFFICE 7

OFFICE 8

GROUP ROOM #2

VESTIBULE

Public Cooridor

Restricted Cooridor

SHAFT

SHAFT

SHAFT

SHAFT

SHAFT

SHAFT

60 180

180 60

MTD = 160'-11" CCPPTT == x6'-3x'-"3"

MAX DEAD END = 24'-8" MTD = 160'-11" CPT = 63'-3"

MAX DEAD END = 24'-8"

FE

FE

FE

HA-5-B

HA-7-A

HA-6-A

HA-6-C

HA-7-B

HA-6-B

HA-5-CHA-4-BHA-8-A

HA-2-C

HA-1-C

HA-3-D

HA-4-A

HA-5-A

HA-3-C

HA-2-B

HA-1-B

HA-3-B

HA-1-A

HA-3-A

HA-2-A

HA-7-C

Veterans Health Administration

Drawing Title Project Title

Location

Date Checked Drawn

Building Number Project Number

Drawing Number

Drawing #

U.S. DEPARTMENT OF VETERANS AFFAIRS

ORLANDO VA HEALTH CARE SYSTEMS

FACILITIES & ENGINEERING SERVICE BOB

ASBESTOS SAMPLE LOCATIONS

BASELINE ASBESTOS SURVEY

FLOOR 04

BUILDING 500

02/26/2025

BUILDING 500- FLOOR 4

SCALE 1/16" = 1'-0"

HA-20-C

HA-20-A,B

HA-19-A,C

HA-18-A

HA-23-A

HA-19-B

HA-22-A

HA-22-B

HA-21-A,B,C

Veterans Health Administration

Drawing Title Project Title

Location

Date Checked Drawn

Building Number Project Number

Drawing Number

Drawing #

U.S. DEPARTMENT OF VETERANS AFFAIRS

ORLANDO VA HEALTH CARE SYSTEMS

FACILITIES & ENGINEERING SERVICE BOB 5 of 5

BUILDING 500

01/17/2025

BUILDING 500- MEZZANINE

SCALE 1/16" = 1'-0"

ASBESTOS SAMPLE LOCATIONS

BASELINE ASBESTOS SURVEY

FLOOR MEZZANINE

APPENDIX A

LABORATORY ANALYTICAL REPORTS

Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

Rick.Cwiklowski Line

APPENDIX B

PHOTO LOG OF HOMOGENEOUS AREAS

Site Address: Orlando VA Building 500 - 5201 Raymond St, Orlando, FL Photographed: October 26, 2024

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-1: Off-white mastic on duct HA-2: Carpet mastic

HA-3: Ceiling tile (smooth and recessed) HA-4: Grey duct mastic

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-5: White joint compound and drywall HA-6: Short grey cove base with yellow adhesive

HA-7: Vinyl tile adhesive HA-8: Red caulking

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-9: White joint compound and drywall HA-10: Off white duct mastic

HA-11: Yellow/green carpet mastic HA-12: 2x2 white ceiling tile (smooth)

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-13: Grey mastic on duct HA-14: Pink fire caulking

HA-15: Grey mastic on PVC HA-16: Grey cove base and tan mastic

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-17: 2x2 tan vinyl flooring and grey mastic HA-18: Off white mastic on duct insulation

HA-19: White mastic on duct insulation HA-20: Grey mastic on duct insulation

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-21: Dark grey mastic on air handling unit

HA-22: Red mastic

HA-23: Off-white joint compound and drywall HA-24: White mastic on duct insulation

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-25: 2X2 white ceiling tile HA-26: Clear/grey mastic on carpet backing

HA-27: Off-white joint compound and drywall HA-28: Grey cove base with clear mastic

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-29: Red mastic HA-30: 3X3 grey vinyl floor tile with red mastic

HA-31: Vinyl tile and mastic HA-32: Clear mastic on carpet backing

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-33: 2x2 ceiling tile (fissured) HA-34: 12x12 white vinyl floor tile with black mastic

HA-35: White drywall with white joint compound HA-36: Red mastic

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-37: 12x12 white floor tile with yellow

HA-38: 12x12 white vinyl floor tile with black

HA-39: Grey cove base with tan mastic HA-40: Laminate wood planking (brown) with black and yellow mastic

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-41: 2x2 white ceiling tile (smooth) HA-42: Beige cove base with yellow mastic

HA-43: White mastic on duct insulation HA-44: White drywall with white joint compound

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-45: Grey mastic on duct HA-46: 2x2 white ceiling tile (fissured)

HA-47: 2x2 white vinyl ceiling tile HA-48: Tan mastic on duct insulation

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-49: White drywall with white joint

HA-50: 12x12 white vinyl floor with yellow

HA-51: Black cove base with clear and tan mastic HA-52: 2x2 white ceiling tile (fissured)

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-53: Tan cove base with yellow mastic HA-54: Yellow mastic on 12x12 tile with black mastic beneath

HA-55: Yellow mastic on white linoleum sheeting, yellow mastic beneath

HA-56: 12x12 grey vinyl floor tile with brown mastic and yellow mastic

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-57: Light brown linoleum plank flooring with yellow mastic HA-58: Dark grey cove base with tan mastic

HA-59: 12x12 white vinyl tile, yellow mastic and grey leveling compound HA-60 1x1 linoleum grey tile with clear/yellow

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-61: Black tall cove base with yellow mastic HA-62: 2x4 grey spotted linoleum tile

HA-63: Tan cove base with white mastic HA-64: Tan mastic under vinyl white sheeting

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-65: 12x12 white vinyl floor tile HA-66: White drywall with joint compound

HA-67: Tall grey cove base with yellow mastic HA-68: Red/blue carpet with yellow mastic

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-69: Red/blue carpet with yellow adhesive HA-70: 2x2 blue/white carpet with yellow

HA-71: Grey short cove base with tan mastic HA-72: Tan cove base with yellow mastic

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-73: Brown plant linoleum flooring with yellow mastic HA-74: 2x4 off white vinyl floor tile with yellow

HA-75: 2x2 white inlay ceiling tile HA-76: White drywall and plaster

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN OPC\THU2015BA - VA Orlando OPC\Photos\Photograph Log - Building 500 - Missing 4.docx

HA-77: 2x2 grey floor tile with yellow mastic HA-78: Tall grey cove base with tan mastic

HA-79: Grey/orange lined carpet with grey leveling compound and mastic HA-80: Light grey linoleum floor with yellow

M:\Data\T\THUJV - THUNDERBIRD-HRP JV, LLC\ORLANDO VA HEALTHCARE SYSTEMS, LAKE BALDWIN…

This is the start of the file's text. The full file is on GovTribe.