Attachment 2 - JUBJ 23-4706 Repair Rooms Bldg 1410 Drawings.pdf
PDF 1 MB Posted
- Attached to
- Repair Rooms, Building 1410 Gunter
- Solicitation number
- FA330024R0004
About this file
This package includes construction drawings and specifications for repair work at Building 1410 on Maxwell Air Force Base, along with the corresponding solicitation for the federal contract opportunity. The drawings detail repairs needed for 12 dorm rooms, including installing new drywall, flooring, smoke detectors, and pipe insulation. Work also involves cleaning, priming and painting walls, doors and trim throughout. The solicitation was issued by the Air Force Air Education and Training Command for repairs at Building 1410 on Maxwell AFB under solicitation number FA330024R0004. Responses were due on September 5, 2023. The opportunity involves construction and facility maintenance services at a government dormitory building.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
UP
D D D D D
W W W W W
ICE
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
DORM RM
ROOM
ROOM
LAUNDRY
MECH.
117a
ELEC.
117b
MEN
117c
WOMEN
PUMPS
115a
STORAGE
ENTRY/LOBBY
DAY ROOM
UP
1. INSTALL 5/8" TYPE X MOLD & MOISTURE RESISTANT GYP. BD. AT SURFACE OF SOFFIT IN EACH BEDROOM, OFFICE AND STORAGE ROOMS WITH APPLY LEVEL 5 DRYWALL FINISH, PRIME AND PAINT (2 COATS). ADJUST SPRINKLER HEADS, REQ'D.
2. CLEAN WALLS AND CLGS WITH PENETRATING DISINFECTANT SOLUTION TO ELIMINATE MILDEW. PRIME AND PAINT (2 COATS) ALL WALLS, CLGS, SOFFIT FACES AND HORZ. SURFACE OF SOFFITS IN BEDROOMS, OFFICE 128, ALL TOILET
ROOMS AND CLOSETS TO INCLUDE CLOSET SHELVING.
3. AT DORM ROOM AND CLOSETS UNINSTALL EXISTING RB AND ADHESIVE, INSTALL LVT FLOORING (SEE SOW), AND
INSTALL NEW 4" RB. MATCH EXISTING RB PROFILE AND COLOR.
4. PREPARE DOOR FRAMES FOR PAINTING, PRIME, AND PAINT (TWO COATS). AT EXTERIOR DOOR FRAMES, PAINT INTERIOR SIDE, INCLUDING JAMB, OF DOOR FRAME. CLEAN AND PAINT INTERIOR DOORS (2 COATS). CLEAN AND PAINT
(2 COATS) INTERIOR FACE OF EXTERIOR DOORS.
5. INSTALL SMOKE DETECTORS REMOVED IN PREVIOUS CONTRACT AT JUNCTION BOX AT CLG. SMOKE DETECTOR MUST
COMPLY WITH UFC 3-600-01.
6. FIRE SEAL PENETRATIONS AND PATCH HOLES IN SLEEPING UNIT WALLS TO INCLUDE PENETRATIONS ABOVE THE CLG
INSIDE THE SOFFITS. SEE FLOOR PLAN FOR SLEEPING UNIT WALLS.
7. CONDUCT ABOVE CLG INSPECTIONS WITH STM PRIOR TO CLOSING UP SOFFITS. COORDINATE INSPECTIONS WITH STM.
GENERAL NOTES FOR ROOMS 119 THRU 130:
PATCH GYP. BD. THROUGHOUT ROOM, AS REQ'D, APPLY LEVEL 5 DRYWALL FINISH, AS REQ'D, PRIME AND PAINT (2 COATS) -
CORNER TO CORNER, FLR TO CLG.
18”x18” PIPE CHASE ACCESS DOOR. 16 GA. STEEL, HINGED WITH 1” EXPOSED FLANGE PIANO HINGE, SCREW DRIVER CAM LATCH, AND WHITE POWDER COAT FINISH. FIELD VERIFY LOCATIONS. COORDINATE 20 GA. STL STUD FRAMING.
REMOVE AND REPLACE COPPER B88 TYPE L 1” DIA. DHW PIPINGWITHIN CHASE IN ROOMS 120, 122, 124 AND 126. USE PRO PRESS FITTINGS. REPAIR SHALL OCCUR DURING SCHEDULED 8-HOUR BLDG DHW SHUT DOWN. INSULATE DHW PIPING USING FIBERGLASS PREFORMED PIPING INSULATION WITH ASJ. SUPPORT NEW PIPING FROM STRUCTURE ABOVE USING CLEVIS
HANGERS 8' ON CENTER. FIELD VERIFY LOCATIONS AND EXTENT.
REMOVE EXISTING GYP. BD. CLG, CORNER TO CORNER. REMOVE ANY ACOUSTICAL BATT INSUL., REMOVE ANY MILDEW, WITHIN MTL STUDS, INSTALL NEW SOUND BATT INSUL. AS REQ'D, INSTALL NEW 5/8" TYPE X GYP. BD., APPLY LEVEL 5 DRYWALL FINISH, PRIME AND PAINT (2 COATS). WHERE WALLS HAVE TWO LAYERS OF GYP. BD. ON ONE SIDE OF MTL STUDS INSTALL TWO LAYERS OF GYP. BD. (STC-50) WALLS. SEAL PENETRATIONS IN WALLS (BOTH SIDES) WITH SEALANT MATCHING THE REQ'D FIRE
RATING.
128A
COMM
EDGE OF SOFFIT
ABOVE - TYP.
4 4
1 2
2 21
PATCH GYP. BD., AS REQ'D, APPLY LEVEL 5 DRYWALL FINISH, PRIME AND PAINT (2 COATS) - CORNER TO CORNER, FLR TO CLG.
REMOVE EXISTING GYP. BD., (CORNER TO CORNER OR EDGE OF COLUMN, FLR TO CLG. OR DECK ABOVE AT RATED WALLS), REMOVE ANY ACOUSTICAL BATT INSUL., REMOVE ANY MILDEW WITHIN MTL STUDS, INSTALL NEW SOUND BATT INSUL. AS REQ'D, INSTALL NEW 5/8" TYPE X GYP. BD., APPLY LEVEL 5 DRYWALL FINISH, PRIME AND PAINT (2 COATS). AT WET WALLS, INSTALL NEW 5/8" TYPE X MOLD & MOISTURE RESISTANT GYP. BD. WHERE WALLS HAVE TWO LAYERS OF GYP. BD. ON ONE SIDE OF MTL STUDS INSTALL TWO LAYERS OF GYP. BD. (STC-50) WALLS. SEAL PENETRATIONS IN WALLS (BOTH SIDES) WITH SEAL
MATCHING THE REQ'D FIRE RATING OF THE WALL.
REMOVE EXISTING GYP. BD., (CORNER TO CORNER OR EDGE OF COLUMN) FROM FLR TO 48" ABOVE F.F., REMOVE ANY ACOUSTICAL BATT INSUL., ANY MILDEW WITHIN MTL STUDS, INSTALL NEW SOUND BATT INSUL. AS REQ'D, NEW 5/8" TYPE X GYP.
BD., APPLY LEVEL 5 DRYWALL FINISH, PRIME AND PAINT (2 COATS). WHERE WALLS HAVE TWO LAYERS OF GYP. BD. ON ONE SIDE OF MTL STUDS INSTALL TWO LAYERS OF GYP. BD. (STC-50) WALLS. SEAL PENETRATIONS IN WALLS (BOTH SIDES) WITH
SEALANT MATCHING THE REQ'D FIRE RATING OF THE WALL.
REPLACE CEILING FANS; SIZED THE SAME AS CURRENT FAN.
SNAKE CONDENSATE DRAIN TO REMOVE BLOCKAGE TO INCLUDE DRAIN LINE TO FAN COIL UNIT.
UNINSTALL LAVATORY AND BASE CABINET. REMOVE EXISTING GYP. BD., (CORNER TO CORNER OR EDGE OF COLUMN, FLR TO CLG.). ANY ACOUSTICAL BATT INSUL., REMOVE ANY MILDEW, WITHIN MTL STUDS, INSTALL NEW SOUND BATT INSUL. AS REQ'D, INSTALL NEW 5/8" TYPE X MOLD & MOISTURE RESISTANT GYP. BD., REINSTALL LAVATORY AND BASE CABINET AND RECONNECT
PLUMBING, APPLY LEVEL 5 DRYWALL FINISH, PRIME AND PAINT (2 COATS).
REPLACE BOTTOM DOOR SEAL.
KEYED NOTES FOR ROOMS 119 THRU 130:
9 9 910 10 10 10 10 10
101010101010
DORM RM DORM RM DORM RM
DORM RM DORM RM DORM RM DORM RM DORM RM
119 121 123 125 127
128126124122
OFFICE STORAGE
STORAGE
11 4 4
ASJ ALL SURFACE JACKET
BD BOARD
CLG CEILING
CPT CARPET
CT CERAMIC TILE
DHW DOMESTIC HOT WATER
DORM DORMITORY
GYP GYPSUM
HORZ. HORIZONTAL
INSUL INSULATION
LVT LUXURY VINYL TILE
MANF MANUFACTURER
MTL METAL
NIC NOT IN CONTRACT
REQ'D REQUIRED
RB RUBBER BASE
RM ROOM
STL STEEL
ABBREVIATIONS:
HATCHED INDICATES AREAS NOT IN
CONTRACT.
LEGEND:
EXISTING WALL TO REMAIN
- REPLACE GYP. BD. ON SIDE INDICATED
EXISTING DOOR TO REMAIN
EXISTING WALL TO REMAIN
EXISTING WALL TO REMAIN
- REPLACE GYP. BD. ON BOTH SIDES
WALL WITH 1-HOUR FIRE RATING
1 1
AutoCAD SHX Text
MAXWELL AFB - GUNTER ANNEX
AutoCAD SHX Text
MAXWELL AFB, ALABAMA 36112
AutoCAD SHX Text
RENEW TWELVE ROOMS BUILDING 1410 MAXWELL A.F.B./GUNTER ANNEX AL
AutoCAD SHX Text Number:
AutoCAD SHX Text Reference
AutoCAD SHX Text Sheet
AutoCAD SHX Text
JUBJ 23-4706
AutoCAD SHX Text
05 SEP 2023
AutoCAD SHX Text Symbol
AutoCAD SHX Text Description
AutoCAD SHX Text Scale:
AutoCAD SHX Text Date:
AutoCAD SHX Text Checked By:
AutoCAD SHX Text Drawn By:
AutoCAD SHX Text Designed By:
AutoCAD SHX Text
42 CES/CEP
AutoCAD SHX Text Reviewed By:
AutoCAD SHX Text Drawing Sheet File:
AutoCAD SHX Text Drawing Folder:
AutoCAD SHX Text Date
AutoCAD SHX Text Approved
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text G
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text 1:1
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text G
AutoCAD SHX Text F
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SHEET OF 2
AutoCAD SHX Text Revisions
AutoCAD SHX Text
JUBJ 23-4706
AutoCAD SHX Text R:\Indesign\gunter\1410\JUBJ 23-4706 Repair Rooms-Dorm 1410\DWG\G1410-A1.dwg
AutoCAD SHX Text
9/21/2023 8:35:37 AM
AutoCAD SHX Text
BREDLOW, SANDRA Y CTR USAF AETC 42 CES/CENMP
AutoCAD SHX Text A-1
AutoCAD SHX Text
AutoCAD SHX Text
FLOOR PLAN - LEVEL 1
AutoCAD SHX Text
PLZ
AutoCAD SHX Text
PLZ
AutoCAD SHX Text
PLZ
AutoCAD SHX Text
PLZ
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text G1410-A1.dwg
AutoCAD SHX Text A2
AutoCAD SHX Text
FLOOR PLAN - LEVEL 1
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text 16'
AutoCAD SHX Text 24'
AutoCAD SHX Text
GRAPHIC SCALE
AutoCAD SHX Text
AutoCAD SHX Text 8'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text 16'
AutoCAD SHX Text 24'
| T-1 Title |
| G1410-A1-A-1 FLR PLAN |
| Sheets and Views |
| A-1 FLR PLAN |
| G1410-A1-A-1 FLR PLAN.pdf |
| Sheets and Views |
| A-1 FLR PLAN |
File details come from the government source that posted it. Updated .