Attachment_2_Final_Drawing.pdf
PDF 15 MB Posted
- Attached to
- USGS FRD OBSERVATORY SHOP/GARAGE PRJ
- Solicitation number
- 140G0222R0018
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
12" HDPE
INV. = 219.05'12" HDPE
INV. = 219.25'
12" RCP
INV. = 218.93'
12" RCP
INV. = 219.09'
12"
12" HDPE
INV. = 220.13'
12" HDPE
INV. = 220.17'12" RCP
INV. = 219.81'
8"
FP
FIN.FLR.
227.69'
12" MTL
INV. = 216.85'
12" MTL
INV. = 215.67'
30"
RD EC
RDCO
S S-1489 S S-1490
23"
W
EC
1"
FIN.FLR.
217.06'
ECEC
EC
EC
U U-1859
RD
EC
EC
EC
EC
ER EB
EB
EM
ECEC
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.CONC
MONUMENTS
EX.GRAVEL
EX.A/C
UNITS
EX.STANDPIPE
SHED
EX.STANDPIPE
SHED
EX.TRANS
EX.GENERATOR
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.OVERGROWN
BROKEN MACADAM
EX.BROKEN MACADAM
EX.MACADAM
EX.MACADAM
EX.MACADAM
EX.MACADAM
EX.GRASS
EX.GRASS
EX.GRASS
EX.GRASS
EX.GRASS
EX.GRASS
EX.GRASS
EX.CONC
LID
EX.TARGET
EX.BRASS DISK
MONUMENT
EX.BLOCK
WALL
EX.ANTENNA
EX.CONC RAMP
TESLA ROAD
N 6759225
E
N 6758875
E
N 6758875
E
LIMIT OF FIELD RUN SURVEY
LIMIT OF FIELD RUN SURVEY
LIMIT OF FIELD RUN SURVEY
LIMIT OF FIELD RUN SURVEY
FORT A P HILL
TAX MAP: 44-A-1
B: 442 / P: 614
11B 11A
11A
11B
EX. 2 CY
DUMPSTER
LIMITS OF EXCLUSION ZONE
D-1
D-2
OHE
CLEAN OUT
DRAIN INLET
ELECTRIC MH
BOLLARD
HAND BOX
ELECTRIC BOX
ELECTRIC CONDUIT
UTILITY POLE
SANITARY MH
SIGN (ONE-POST)
STORM DRAIN MH
STREET LIGHT
TRAVERSE STATION
WATER VALVE
SPOT ELEVATION
MAJOR CONTOUR
MINOR CONTOUR
CONC. CURB
SURVEY LIMITS
FENCE LINE
O/H ELECTRIC
U/G ELECTRIC
U/G GAS
U/G SANITARY
U/G STORM
UG WATER
U/G TELEPHONE
PROPERTY LINE
E
G
SS
D W
C.O.
X X
EXISTINGDESCRIPTION
BUILDING EX. BLDG
BITUMINOUS CONCRETE PAVING EX. MACADAM
+ 625.5
T
REMOVE
DECIDUOUS / EVERGREEN TREES 6"12" 3"
EX. CONC.PORTLAND CEMENT CONCRETE
LEGEND
BITUMINOUS MILL AND OVERLAY PAVING
D-1 SAW CUT EXISTING BITUMINOUS CONCRETE PAVEMENT.
D-2 2" MILL AND OVERLAY OF EXISTING BITUMINOUS CONCRETE PAVEMENT.
DEMOLITION NOTES
GENERAL NOTES
1. THIS PLAT IS BASED UPON A FIELD-RUN TOPOGRAPHIC SURVEY PERFORMED BY WBCM
IN JULY, 2021 AND REFLECTS SITE CONDITIONS AS OF THAT DATE.
2. COORDINATES AND DIRECTIONS SHOWN HEREON ARE REFERRED TO THE VIRGINIA
STATE PLANE NORTH COORDINATE SYSTEM, NAD 83/2011 AS DETERMINED FROM REAL
TIME KINEMATIC SURVEYING AS BROADCAST BY THE LEICA SMARTNET NETWORK.
3. ELEVATIONS SHOWN HEREON ARE REFERRED TO THE NORTH AMERICAN VERTICAL
DATUM OF 1988 (NAVD 88), AS DETERMINED BY R.T.K. G.P.S. OBSERVATIONS AS
BROADCAST BY THE LEICA SMARTNET NETWORK(GEOID18).
4. ADDITIONAL SPOT ELEVATIONS RESIDE IN THE ELECTRONIC VERSION OF THIS
DRAWING BUT ARE NOT PLOTTED HEREON.
5. THE LOCATION OF EXISTING UNDERGROUND UTILITIES IS SHOWN IN AN APPROXIMATE
WAY ONLY. THE DESCRIPTION OF THE UNDERGROUND UTILITIES AS SHOWN HEREON
WERE BASED SOLEY UPON FIELD OBSERVATIONS AND HAVE NOT BEEN COMPARED TO
OR VERIFIED WITH RECORD UTILITY DRAWINGS OR FIELD TEST PITS. THE SIZE, TYPE
AND LOCATION OF THE UTILITY LINES SHOULD BE VERIFIED BY THE USER OF THIS
DRAWING.
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ACTUAL SITE CONDITIONS
PRIOR TO THE START OF ANY WORK. THERE IS NO WARRANTY OR GUARANTEE ON THE
COMPLETENESS OR CORRECTNESS OF THE EXISTING CONDITION INFORMATION. ANY
DISCREPANCY FOUND SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT/ENGINEER PRIOR TO THE START OF ANY WORK.
7. THE WORDS "CERTIFY" OR "CERTIFICATION" AS USED HEREON ARE UNDERSTOOD TO
BE AN EXPRESSION OF PROFESSIONAL OPINION BY THE UNDERSIGNED SURVEYOR,
BASED UPON HIS BEST KNOWLEDGE, INFORMATION, AND BELIEF. AS SUCH, IT DOES
NOT CONSTITUTE A GUARANTEE NOR A WARRANTY, EXPRESSED OR IMPLIED.
W.B.C.M. SURVEY TRAVERSE CONTROL LISTING
PT# NORTHING EASTING ELEV. DESCRIPTION
900 6,758,826.57 11,806,729.89 221.43 REBAR & CAP
901 6,759,207.51 11,806,331.49 213.61 REBAR & CAP
902 6,759,428.41 11,806,449.90 212.09 REBAR & CAP
903 6,759,228.67 11,806,604.05 222.40 REBAR & CAP
904 6,759,176.88 11,806,833.05 224.60 REBAR & CAP
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1"=30'-0" 30 0 15 30 60
C01
R.S.S.
B.W.L.
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DEGIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
Designing Infrastructure for Tomorrow®
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
18905.002 12-16-2021
FINAL SUBMISSION
12-16-2021
FINAL SUBMISSION
EXISTING CONDITIONS PLAN
WHITNEY BAILEY COX & MAG
12/16/21
12" HDPE
INV. = 219.05'12" HDPE
INV. = 219.25'
12" RCP
INV. = 218.93'
12" RCP
INV. = 219.09'
12"
12" HDPE
INV. = 220.13'
12" HDPE
INV. = 220.17'12" RCP
INV. = 219.81'
8"
FP
FIN.FLR.
227.69'
12" MTL
INV. = 216.85'
12" MTL
INV. = 215.67'
30"
RD EC
RDCO
S S-1489 S S-1490
23"
W
EC
1"
FIN.FLR.
217.06'
RD
EC
EC
EC
ER EB
EB
EM
ECEC
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.CONC
MONUMENTS
EX.GRAVEL
EX.A/C
UNITS
EX.STANDPIPE
SHED
EX.STANDPIPE
SHED
EX.TRANS
EX.GENERATOR
EX.OVERGROWN
BROKEN MACADAM
EX.MACADAM
EX.MACADAM
EX.MACADAM
EX.MACADAM
EX.GRASS
EX.GRASS
EX.GRASS
EX.GRASS
EX.GRASS
EX.BRASS DISK
MONUMENT
EX.BLOCK
WALL
EX.ANTENNA
EX.CONC RAMP
TESLA ROAD
N 6759225
E
N 6758875
E
N 6758875
E
LIMIT OF FIELD RUN SURVEY
LIMIT OF FIELD RUN SURVEY
FORT A P HILL
TAX MAP: 44-A-1
B: 442 / P: 614
11B 11A
11A
11B
EX. 2 CY
DUMPSTER
LIMITS OF EXCLUSION ZONE
LOD
LO
D
LOD
E
E
E
E
E
E
E
E
E
E E
E E
E E
222223
OHE
CLEAN OUT
DRAIN INLET
ELECTRIC MH
BOLLARD
HAND BOX
ELECTRIC BOX
ELECTRIC CONDUIT
UTILITY POLE
SANITARY MH
SIGN (ONE-POST)
STORM DRAIN MH
STREET LIGHT
TRAVERSE STATION
WATER VALVE
SPOT ELEVATION
MAJOR CONTOUR
MINOR CONTOUR
CONC. CURB
SURVEY LIMITS
FENCE LINE
O/H ELECTRIC
U/G ELECTRIC
U/G GAS
U/G SANITARY
U/G STORM
UG WATER
U/G TELEPHONE
PROPERTY LINE
E
G
SS
D W
C.O.
X X
EXISTINGDESCRIPTION
BUILDING EX. BLDG
BITUMINOUS CONCRETE PAVING EX. MACADAM
+ 625.5
T
DECIDUOUS / EVERGREEN TREES 6"12" 3"
EX. CONC.PORTLAND CEMENT CONCRETE
LEGEND
BITUMINOUS MILL AND OVERLAY PAVING
NEW
+ 221.5
LEGEND
N-1 MEET EXISTING CONDITIONS.
N-2 NEW SHOP GARAGE BUILDING, SEE ARCHITECTURAL DRAWINGS FOR DETAILS.
N-3 NEW DOUBLE WALL 300 GALLON FUEL TANK, SEE DETAIL #3 ON SHEET C04.
N-4 NEW FULL DEPTH BITUMINOUS CONCRETE PAVING, SEE DETAIL #1 ON SHEET C03.
N-5 NEW 2" MILL AND OVERLAY OF BITUMINOUS CONCRETE PAVING, SEE DETAIL #2 ON
SHEET C03.
N-6 NEW CONCRETE BOLLARD, SEE STRUCTURAL DRAWLING'S FOR DETAILS.
N-7 NEW 1'-0" DEEP CONCRETE CONTAINMENT BARRIER,SEE DETAIL #4 ON SHEET C03.
CONSTRUCTION NOTES
NEW BUILDING
FF. EL. 223.28
N-2
N-3 N-6
(3TYP)
LOD
LOD
LOD
LOD
LO
D
LO
D
LO
D
LOD
LOD
LOD
SF
SF
SF
SF
SF
70, L.F. SILT FENCE
E E
E E
E E
N-1
N-7
N-4
(4 TYP)
0.5% 223.20 223.20
223.15
222.95
223.15
222.00
223.20
5.0%
222.65
223.20
1.4%
222.53
223.20
222.41
223.39 4.3%
223.17
1.0%
222223
2.0%
222.68
223.20
LIMITS OF DISTURBANCE
= 3,550 SQ.FT.
5'
5'
5.5' 6.25'
5'
5'
21.83'
37.83'
10'
GEOMETRY POINT TABLE
PT #
DESCRIPTION
CORNER BUILDING
CORNER BUILDING
CORNER BUILDING
CORNER BUILDING
NORTHING
6759054.10
6759091.62
6759094.39
6759056.86
EASTING
11806851.92
11806847.12
11806868.78
11806873.57
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1"=30'-0" 30 0 15 30 60
GENERAL NOTES
1. THIS PLAT IS BASED UPON A FIELD-RUN TOPOGRAPHIC SURVEY PERFORMED BY WBCM
IN JULY, 2021 AND REFLECTS SITE CONDITIONS AS OF THAT DATE.
2. COORDINATES AND DIRECTIONS SHOWN HEREON ARE REFERRED TO THE VIRGINIA
STATE PLANE NORTH COORDINATE SYSTEM, NAD 83/2011 AS DETERMINED FROM REAL
TIME KINEMATIC SURVEYING AS BROADCAST BY THE LEICA SMARTNET NETWORK.
3. ELEVATIONS SHOWN HEREON ARE REFERRED TO THE NORTH AMERICAN VERTICAL
DATUM OF 1988 (NAVD 88), AS DETERMINED BY R.T.K. G.P.S. OBSERVATIONS AS
BROADCAST BY THE LEICA SMARTNET NETWORK(GEOID18).
4. ADDITIONAL SPOT ELEVATIONS RESIDE IN THE ELECTRONIC VERSION OF THIS
DRAWING BUT ARE NOT PLOTTED HEREON.
5. THE LOCATION OF EXISTING UNDERGROUND UTILITIES IS SHOWN IN AN APPROXIMATE
WAY ONLY. THE DESCRIPTION OF THE UNDERGROUND UTILITIES AS SHOWN HEREON
WERE BASED SOLEY UPON FIELD OBSERVATIONS AND HAVE NOT BEEN COMPARED TO
OR VERIFIED WITH RECORD UTILITY DRAWINGS OR FIELD TEST PITS. THE SIZE, TYPE
AND LOCATION OF THE UTILITY LINES SHOULD BE VERIFIED BY THE USER OF THIS
DRAWING.
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ACTUAL SITE CONDITIONS
PRIOR TO THE START OF ANY WORK. THERE IS NO WARRANTY OR GUARANTEE ON THE
COMPLETENESS OR CORRECTNESS OF THE EXISTING CONDITION INFORMATION. ANY
DISCREPANCY FOUND SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT/ENGINEER PRIOR TO THE START OF ANY WORK.
7. THE WORDS "CERTIFY" OR "CERTIFICATION" AS USED HEREON ARE UNDERSTOOD TO
BE AN EXPRESSION OF PROFESSIONAL OPINION BY THE UNDERSIGNED SURVEYOR,
BASED UPON HIS BEST KNOWLEDGE, INFORMATION, AND BELIEF. AS SUCH, IT DOES
NOT CONSTITUTE A GUARANTEE NOR A WARRANTY, EXPRESSED OR IMPLIED.
W.B.C.M. SURVEY TRAVERSE CONTROL LISTING
PT# NORTHING EASTING ELEV. DESCRIPTION
900 6,758,826.57 11,806,729.89 221.43 REBAR & CAP
901 6,759,207.51 11,806,331.49 213.61 REBAR & CAP
902 6,759,428.41 11,806,449.90 212.09 REBAR & CAP
903 6,759,228.67 11,806,604.05 222.40 REBAR & CAP
904 6,759,176.88 11,806,833.05 224.60 REBAR & CAP
R.S.S.
B.W.L.
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DEGIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
Designing Infrastructure for Tomorrow®
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
18905.002 12-16-2021
FINAL SUBMISSION
12-16-2021
FINAL SUBMISSION C02
SITE LAYOUT PLAN
ENLARGEMENT DETAIL
SCALE: 1" = 10'
SEE ENLARGEMENT
DETAIL THIS SHEET
1"=10'-0" 10 0 5 10 20
VARIES
1'-3" TO 2'-1"
24" MIN.
SEE NOTE 2.
2" CLR. TYP.
3" CLR. TYP.
VARIES, 2" MIN.
SEE NOTE 1.
NOTES:
1. SEE PLAN FOR TOP OF WALL ELEVATION.
2. CONSTELLATION ENERGY SHALL CONFIRM THE BOTTOM OF FOOTING ELEVATION BASED ON
SOIL CONDITIONS AND EXISTING UTILITIES -24" MIN.
3. CONCRETE PROVIDED SHALL HAVE A MIN. 28 DAY COMPRESSIVE STRENGTH OF 3 KSI.
4. REINFORCING STEEL SHALL BE DEFORMED GRADE 60 BARS CONFORMING TO ASTM 615.
1'0.5'1'
#4 @ 8", VERTICAL CENTER
IN WALL.
#5 @ 12", HORIZONTAL.
2" x 3" KEY
(4) #5 CONTINUOUS TOP &
BOTTOM.
PAVEMENT SECTION
SEE DETAIL 2,
THIS SHEET.
1" CHAMFER, TYP.
CAULK AND SEAL JOINT.
SEE DETAIL 6, THIS SHEET.
C03 SCALE: 1" = 5'-0"
CONTAINMENT DIKE WALL BARRIER
SECTION
C03 SCALE: 1" = 1'-0"
BITUMINOUS CONCRETE PAVING
SECTION
8" 1 1 2"
AGGREGATE BASECOURSE CR6
(CRUSHER RUN)
BITUMINOUS CONCRETE BINDER
COURSE HMA SUPERPAVE 19.0 mm
(PG 64-22)
BITUMINOUS CONCRETE SURFACE
COURSE HMA SUPERPAVE 9.5mm (PG 64-22)
FINISHED GRADE
3 1 2"
TOP OF COMPACTED SUBGRADE
TACK COAT
NOTES:
1. MAINTAIN POSITIVE DRAINAGE AT ALL TIMES.
2. AT PERIMETERS OF OVERLAY PAVING AREAS: MEET NEW ROAD PAVING
SECTION FINISHED GRADE FLUSH.
3. MILL THE TOP 2INCHES OF THE PARKING LOT AND ROADWAY SURFACE.
4. EXAMINE THE MILLED SURFACE. CUT OUT ANY FAILED BASE COURSE AREA
EXHIBITING ALLIGTOR OR PATCHWORK CRACKING, WHICH MAY HAVE BEEN
HIDDEN BELOW THE SURFACE COURSE, TO EXPOSE THE UNDERLYING SOIL OR
CRUSHED STONE BASE.
5. CLEAN EXPOSED LINEAR CRACKS IN THE EXPOSED SURFACE, FILLING CRACKS
THINNER THAN 1/4-INCH WIDTH WITH LIQUID ASPHALT AND FILLING CRACKS
LARGER THAN 1/4-INCH WITH SAND/ASPHALT MIX.
6. PLACE THE LIQUID ASPHALT TACK COAT AND APPROPRIATE PAVEMENT GRADE
GEOTEXTILE FABRIC ACROSS THE ENTIRE OVERLAY AREA TO MEET
MANUFACTURER'S REQUIREMENTS. PAVING FABRIC SHOULD BE INSTALLED
BY AN APPROVED SPECIALTY CONTRACTOR.
7. PLACE A 2-INCH THICK OVERLAY SECTION OF HOT-MIX ASPHALT (9.5MM
SUPERPAVE, LEVEL 10 OVER THE ENTIRE OVERLAY AREA.
C03 SCALE: 1" = 1'-0"
MILL AND OVERLAY PAVEMENT SECTION
SECTION
2"
EXISTING AGGREGATE BASECOURSE
TOP OF COMPACTED SUBGRADE
EXISTING BITUMINOUS CONCRETE
2" BITUMINOUS CONCRETE SURFACE
COURSE HMA SUPERPAVE 9.5mm
(PG 64-22)
TACK COAT
FINISHED GRADE
TRUPAVE ENGINEERED PAVING MAT OR APPROVED EQUAL
R.S.S.
B.W.L.
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DEGIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
Designing Infrastructure for Tomorrow®
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
18905.002 12-16-2021
FINAL SUBMISSION
12-16-2021
FINAL SUBMISSION C03
SITE DETAILS
C03 SCALE: 1" = 1'-0"
300 GALLON DOUBLE WALL TANK
SECTION
3"12"
1% MIN.
0.5%
0.5%
3 4" 3 4"
VARIES
1'-3" TO 2'-1"
24" MIN.
SEE NOTE 2.
2" CLR. TYP.
3" CLR. TYP.
VARIES, 2" MIN.
SEE NOTE 1.
NOTES:
1. SEE PLAN FOR TOP OF WALL ELEVATION.
2. CONSTELLATION ENERGY SHALL CONFIRM THE BOTTOM OF FOOTING ELEVATION BASED ON
SOIL CONDITIONS AND EXISTING UTILITIES -24" MIN.
3. CONCRETE PROVIDED SHALL HAVE A MIN. 28 DAY COMPRESSIVE STRENGTH OF 3 KSI.
4. REINFORCING STEEL SHALL BE DEFORMED GRADE 60 BARS CONFORMING TO ASTM 615.
1'0.5'1'
0.5'
FL
OW
SINGLE FILTER MEDIA OUTFALL
1"TYP.
3"
TYP.3"TYP.
12" TYP.
1.5 " M
IN
SINGLE OUTFALL WALL SECTION
#4 @ 8", VERTICAL CENTER
IN WALL.
#5 @ 12", HORIZONTAL.
2" x 3" KEY
(4) #5 CONTINUOUS TOP &
BOTTOM.
PAVEMENT SECTION
SEE DETAIL 2,
THIS SHEET.
1" CHAMFER, TYP.
CAULK AND SEAL JOINT.
SEE DETAIL 6, THIS SHEET.
C03 SCALE: 1" = 5'-0"
CONTAINMENT DIKE WALL BARRIER
SECTION
2"
1 2"
27" LAP
27" LAP
6" PETRO PIPE FILTER
MEDIA OUTFALLS.
24"X12"X3" PAVEMENT
DEPRESSION FOR FILTER
MEDIA REPLACEMENT
CONTAINMENT WALL, SEE
DETAIL THIS SHEET
NEW CONTAINMENT WALL
#4 REBAR, TYP.FILTER MEDIA, TYP.
INVERT.
TOP OF WALL
6" PETRO PIPE SLEEVE WITH FLANGE
CAST INTO WALL PER MANUFACTURER
SPEC. OR APPROVED EQUAL.
INVERT OUT
INVERT IN
CONTAINMENT WALL,
SEE DETAILS THIS SHEET
STAINLESS FASTENERS
SPI PETRO-PIPE OR
APPROVED EQUAL
PAVEMENT SECTION,
SEE DETAIL ON SHEET C03CAULK AND SEAL JOINT,
SEE DETAIL 6, THIS SHEET
DEPRESSED AREA FOR FILTER
MEDIA REPLACEMENT
EXISTING / PROPOSED GRADE
CAST SLEEVE PER MANUFACTURER
SPEC. SEE SECTION VIEW FOR REBAR
PLACEMENT.
C04 SCALE: 1/2" = 1'-0"
FILTER MEDIA OUTFALL DETAIL
SECTION
C04 SCALE: 1" = 1'-0"
CAULK AND SEAL JOINT DETAIL
SECTION
PROVIDE W=1/2" X D=1" CAULK CHANNEL.
CAULK PAVEMENT CONNECTION WITH:
SONNEBORN SONOLASTIC NP1
POLYURETHANE JOINT SEALANT.
PROPOSED CONTAINMENT WALL
PAVEMENT SECTION,
SEE DETAIL ON SHEET C03
C04 SCALE: 1" = 1'-0"
TYPICAL REINFORCING AND JOINT DETAIL
SECTION
CUT ALTERNATE LONGITUDINAL BARS AT
CONTROL AND CONSTRUCTION JOINTS.
PROVIDE CONTROL OR CONSTRUCTION
JOINTS @ 25'-0" MAX. ON CENTER
CONTRACTOR SHALL SUBMIT SHOP
DRAWINGS WITH LOCATION OF JOINTS
BEFORE CONSTRUCTION.
VOLCLAY WATERSTOP FULL HEIGHT OF WALL.
2" X 3" KEY (TYP.) W/ VOLCLAY WATERSTOP FULL
HEIGHT OF WALL.
1/2" DEEP GROOVE
NOTES:
1. PROVIDE CORNER BARS OF THE SAME SIZE AND SPACING AS THE
HORIZONTAL WALL REINFORCING.
CORNER REINFORCING DETAIL CONSTRUCTION JOINT
CONTROL JOINT
R.S.S.
B.W.L.
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DEGIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
Designing Infrastructure for Tomorrow®
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
18905.002 12-16-2021
FINAL SUBMISSION
12-16-2021
FINAL SUBMISSION C04
SITE DETAILS
30'-0" 3'-4" 4'-0"
2'-8" 9'-8" 2'-0" 9'-8" 6'-0" 3'-4" 4'-0"
3'- 4"
3'- 4"
5'- 8"
3'- 4"
5'- 8"
3'- 4"
10'-0"8"25'-4"
'-4
2'- 8"
3'- 4"
2'- 0"
4'- 0"
1'- 3"
WORKSHOPGARAGE
DASHED LINES INDICATE
BLDG OUTLINE BELOW
+3 /12
S
LO
PE
1'-
6" 1'-
6"
6" DIAM BOLLARD
C
A301A101
A
A301A101
B
A301A101
D01D02D03
D04D05
W1
W1
W2
W1
PROJECT NAME: FREDERICKSBURG SHOP/GARAGE BUILDING
FREDERICKSBURG, VIRGINIA
APPLICABLE CODES:
2012 Virginia Uniform State Building Code (USBC)
2018 International Building Code, (IBC)
2015 International Conservation Code (IECC)
2018 International Mechanical Code (IMC)
2011 National Electrical Code NEC (EC)
IBC 2018 REVIEW:
Proposed Facility = 826 SF, One Story, 16' Max Height
Occupancy by Code = 4
Chapter 3: Use Group & Occupancy Classification : Section 311.2 Moderate-hazard storage, Group S-1
Allowable Building Height (Table 504.3) = 110', Construction Type IIB Not-Sprinklered (Proposed = 16')
Allowable Number of Stories (Table 504.4) = 2, Construction Type IIB Not-Sprinklered (Proposed = 1)
Allowable Area Factor = 17,500 SF, Construction Type IIB Not-Sprinklered (Proposed 826 SF)
Chapter 6: Table 601 (Fire Resistance Rating Requirements)
Primary Structural Frame Type IIB Construction = 0 HR
Bearing Wall, Exterior = 0 HR
Bearing Wall, Interior = 0 HR
Non-Bearing Wall, Exterior (Table 602) = 0 HR
Non-Bearing Wall, Interior = 0 HR
Floor Construction = 0 HR
Roof Construction = 0 HR
Chapter 9: Automatic Sprinkler Systems (Section 903.2.9 Group S-1) = Not Required
Chapter 10: Means of Egress (Table 1004.1.2)
Accessory storage area = 300 gross
Business areas = 100 gross
Occupant Load = 4 Occupants
Section 1005.1 Minimum required egress multiplier = 0.3 inches for stairways and 0.2 for other egress components.
Section 1005.3.2 Egress Components (Doors) = 0.2" per occupant (32" wide clear door opening provided)
Table 1015.1 Spaces with one exit or exit doorway less than Maximum Occupant Load of 29.
Table 1017.2 Exit Access Travel Distance
Storage S-1 = 200' without Sprinkler System (travel distance with building complies with requirements)
Section 1020.4. Building does not have any dead end corridors.
Table 1021.2 Stories with One Exit (29 max occupants & 75' travel distance). Building complies with requirements.
IECC TABLE C402.2
CLIMATE ZONE 4
Insulation Entirely Above Deck R-25ci
Walls, Above Grade, Mass R-9.5ci
Slab-on-Grade, Unheated R-10 for 24" below
W H
MATL TYPE MATL TYPE
W1
W2
W H
MATL TYPE MATL TYPE
ROOM FINISH SCHEDULE
ROOM NAME FLOOR
N S E W
WALLS
CEILING NOTES
DOOR AND FRAME SCHEDULE
DOOR
NO.
W H THK
SIZE
MATL TYPE
DOOR
MATL TYPE
HEAD JAMB SILL
DETAIL
FRAME
HARDW
SET
REMARKS
TYPE
WIDTH HEIGHT
DIMENSIONS
MATERIAL REMARKS
INSULATED GLAZING
D01 3'-0" 7'-2" 1 3/4" FRP 1
HARDWARE SET #2: DOORS D01 & D03
-3 HINGES
-1 ENTRANCE & DEADBOLT LOCKSET
-1 DOOR CLOSER
-WEATHERSTRIPPING
-ALUM THRESHOLD
D02 1 3/4" 2
D03 1 3/4" 1
D04 9'-8"
D05
3'-4" 4'-0"
3'-4"
WINDOW SCHEDULE
GARAGE
WORKSHOP
FRP = FIBERGLASS REINFORCED POLYESTER
AT = ALUMINUM THRESHOLD
HARDWARE SET #5: DOOR D02
-3 HINGES
-1 PASSAGE SET
-1 DOOR CLOSER
HARDWARE SCHEDULE
C.S.
C.S.
C.S. = CONCRETE SEALER
GB = GYPSUM BOARD, PAINTED
10'-0"
E = EXPOSED STRUCTURE, PAINTED
METAL-CLAD WOOD
FRP
FRP
FRP
FRP
FRP
P
3'-0" 7'-2"
3'-0" 7'-2"
9'-8" 10'-0"
A
B
A
STEEL C -
STEEL C -
INSULATED COILING DOOR, ELECTRIC
INSULATED COILING DOOR, ELECTRIC
F1
4'-0" METAL-CLAD WOOD
CLEAR & TEMPERED GLAZING
POLISHED CONCRETE FLOOR
POLISHED CONCRETE FLOOR
P P P
P P P P
E
GB
CEILING
HEIGHT
8'-0"
A C
F1
B
F1
F1
A2/A302 -
A3/A302
A3/A302
D3/A301
D3/A301
J1/A301
J1/A301
J2/A301
J3/A301
J3/A301
AT
AT
TYPE
SLIDING
FIXED
PROJECT INFORMATION
DRYWALL CEILING
LIGHT FIXTURE-
SEE ELECTRICAL
NCAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1/4"=1'-0" 1286410
A1
SCALE: 1/4" = 1'-0"
FLOOR PLAN
A101A101
A3
SCALE: 1/4" = 1'-0"
ROOF PLAN
A01A01
ROOF PLAN & SCHEDULES
A101
FLOOR PLAN,
A2
SCALE: 1/4" = 1'-0"
REFLECTED CEILING PLAN
A01A01
18905.002
12-16-2021
FINAL SUBMISSION
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DESIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
STAMP:
AutoCAD SHX Text
DOOR TYPE
AutoCAD SHX Text 12"x12" LOUVER @ D04 ONLY
AutoCAD SHX Text
TEMPERED GLASS VISION PANEL
AutoCAD SHX Text
FRAME TYPE
FINISH FLOOR
EL: 0.00'
FINISH FLOOR
EL: 0.00'
FINISH FLOOR
EL: 0.00'
FINISH FLOOR
EL: 0.00'
FIBER CEMENT SIDING
ASPHALT ROOF SHINGLES
ALUM CLAD FASCIA BOARD
METAL CLAD SLIDING WINDOW
w/ CEMENT BOARD TRIM
FIBER CEMENT SIDING
ALUM CLAD FASCIA BOARD
9'-8" W x 10'-0" H COILING
OVERHEAD DOOR
CEMENT BOARD DOOR
TRIM, TYP
FIBER CEMENT SIDING
ALUM CLAD RAKE BOARD
FIBER CEMENT SIDING
ALUM CLAD RAKE BOARD
FRP DOOR & FRAME
CONCRETE PAD @ DOOR
CONCRETE PAD
@ DOOR FINISH GRADE
FINISH GRADE
FINISH GRADE
FINISH GRADE
METAL CLAD SLIDING WINDOW
w/ CEMENT BOARD TRIM
METAL CLAD SLIDING WINDOW
w/ FIBERGLASS TRIM
SIGNAGE
PAINTED 6" DIAM x 42"
HIGH BOLLARD
BOLLARD BEYOND
BOLLARD BEYOND
+3/12 SLOPE
+3/12 SLOPE
SIGNAGE INFORMATION:
SINAGE TEXT: WORKSHOP
SIZE: 5"H x 15"W
FONT SIZE: 1 1/2"
FONT STYLE: STANDARD BOLD
FONT COLOR: WHITE
BACKGROUND: BLACK
MATERIAL: ALUMINUM
FRP DOOR &
FRAME
4'- 6"
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1/4"=1'-0" 1286410
N
SCALE: 1/4" = 1'-0"
NORTH ELEVATION
A201A101
W
SCALE: 1/4" = 1'-0"
WEST ELEVATION
A201A101
S
SCALE: 1/4" = 1'-0"
SOUTH ELEVATION
A201A101
E
SCALE: 1/4" = 1'-0"
EAST ELEVATION
A201A101
ELEVATIONS
A201
EXTERIOR
18905.002
12-16-2021
FINAL SUBMISSION
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DESIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
STAMP:
FINISH FLOOR
EL: 0.00'
FINISH FLOOR
EL: 0.00'
T.O. CMU
EL: 14.00'
T.O. MASONRY
EL: 8.67'
FINISH FLOOR
EL: 0.00'
TYPICAL WALL CONSTRUCTION
· FIBER CEMENT SIDING ON WOOD FURRING
· 2-1/2" RIGID INSULATION (R-9.5 CI )
· DAMPPROOFING ON 8" CMU (SEE STRUC)
T.O. CMU
EL: 14.00'
T.O. MASONRY
EL: 8.67'
TYPICAL ROOF CONSTRUCTION
· ASPHALT SHINGLE ROOF
· SYNTHETIC UNDERLAYMENT
· 1/2" ROOF SHEATHING ON WOOD FURRING
· 4-1/2" RIGID INSULATION (R-25 CI)
· 5/8" PLYWOOD SHEATHING
· WOOD FRAMING @ 24" OC (SEE STRUC)
TYPICAL FLOOR CONSTRUCTION
· POLISHED 6" CONCRETE SLAB (SEE STRUC)
· 10 MIL VAPOR BARRIER
· 4" GRAVEL BASE
· 2" x 24" VERT & HORIZ RIGID INSULATION (R-10)
AT BUILDING PERIMETER
10' HIGH ELEC
OVERHEAD
COILING DOOR
GARAGE
TYPICAL ROOF CONSTRUCTION
TYPICAL WALL CONSTRUCTION
BUILDING SECTION NOTES
6" DIAM x 42"
HIGH PAINTED
METAL BOLLARD
TYPICAL FLOOR CONSTRUCTION
+3/12 SLOPE
TYPICAL ROOF CONSTRUCTION
METAL CLAD SLIDING WINDOW
WORKSHOP
TYPICAL ROOF CONSTRUCTION
TYPICAL WALL CONSTRUCTION
+3/12 SLOPE
METAL CLAD SLIDING WINDOW
8'- 0"
WORKSHOPGARAGE
TYPICAL WALL CONSTRUCTION
FRP DOOR & FRAME
TYPICAL FLOOR CONSTRUCTION
8'- 0"
DRYWALL CEILING
1'-6"
1'-6"
1'-6"
1'-6"
CONCRETE PAD @ DOOR
EXPOSED ROOF JOISTS
FINISH GRADE
FINISH GRADE
DRYWALL PARTITION
TO UNDERSIDE OF
STRUCTURE
EXPOSED ROOF
JOISTS & ROOF DECK
3'- 4"
DRYWALL
CEILING
A1
C2
C3
B2
C2A3
A2
DOOR LINTEL- REFER TO
STRUCTURAL
FRP DOOR & FRAME
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
2 1/2" (R-9.5) RIGID
INSULATION
1x3 FIBER CEMENT
WINDOW TRIM
FLASHING
1/2" CEMENT BD TRIM FRP DOOR & FRAME
SEALANT, BOTH SIDES
CEMENT BOARD TRIM
1x3 CEMENT BD
DOOR TRIM
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
CEMENT BOARD TRIM
1x3 CEMENT BD
DOOR TRIM
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
FRP DOOR & FRAME
SEALANT, BOTH SIDES
SHIM
8: CMU
INSULATED COILING
DOOR
STEEL ANGLE GUIDE
8" CMU
STEEL ANGLE JAMB
METAL CLAD WD
WINDOW
SEALANT, BOTH SIDES
CEMENT BOARD TRIM
1x3 CEMENT BD
DOOR TRIM
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1/4"=1'-0" 1286410
B
SCALE: 1/4" = 1'-0"
BUILDING SECTION
A301A101
A
SCALE: 1/4" = 1'-0"
BUILDING SECTION
A301A101
C
SCALE: 1/4" = 1'-0"
BUILDING SECTION
A301A101
SECTIONS
A301
BUILDING
H1
SCALE: 1 1/2" = 1'-0"
DOOR HEAD DETAIL
A301A101
J1
SCALE: 1 1/2" = 1'-0"
DOOR JAMB DETAIL
A301A101
J2
SCALE: 1 1/2" = 1'-0"
DOOR JAMB DETAIL
A301A101
J3
SCALE: 1 1/2" = 1'-0"
DOOR JAMB DETAIL
A301A101
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1 1/2"=1'-0" 210.50
J4
SCALE: 1 1/2" = 1'-0"
WINDOW JAMB DETAIL
A301A101
18905.002
12-16-2021
FINAL SUBMISSION
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DESIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
STAMP:
AutoCAD SHX Text A301
AutoCAD SHX Text A302
AutoCAD SHX Text A301
AutoCAD SHX Text A302
AutoCAD SHX Text A301
AutoCAD SHX Text A302
AutoCAD SHX Text A301
AutoCAD SHX Text A302
AutoCAD SHX Text A301
AutoCAD SHX Text A302
AutoCAD SHX Text
SIMILAR
AutoCAD SHX Text A301
AutoCAD SHX Text A302
AutoCAD SHX Text A301
AutoCAD SHX Text A302
2" RIGID INSULATION-
24" HORIZONTAL
DAMPPROOFING
12" CMU, GROUT
SOLID
2" RIGID INSULATION
HORZ JOINT REINF @
16" OC
6" CONCRETE SLAB-
SEE STRUCTURAL
EXPANSION JOINT
SILL FLASHING
EXTERIOR SILL
EXTENSION BY
WINDOW
MANUFACTURER
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
CONCRETE FOOTING-
SEE STRUCTURAL
SEALANT AROUND
WINDOW FRAME
SHIM, AS REQUIRED
METAL CLAD WOOD
WINDOW, SEE
WINDOW SCHEDULE
DAMPPROOFING
ON 8" CMU
FINISH GRADE
2 1/2" RIGID
INSULATION
BASE FLASHING
SOLID BULLNOSE 8"
CMU WINDOW SILL
SEALANT AROUND
WINDOW FRAME
STEEL LINTEL- SEE
STRUCTURAL
SEALANT AROUND
WINDOW FRAME
METAL CLAD WOOD
WINDOW, SEE
WINDOW SCHEDULE
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
HANGAR SPACING @
48" OC MAX
1 1/2" COLD ROLLED
CHANNELS @ 48" OC MAX
FURRING CHANNELS @
24" OC
1/2" GYPSUM BOARD
3'- 4"
4'- 0 3
/8"
2 1/2" (R-9.5) RIGID
INSULATION
1x3 FIBER CEMENT
WINDOW TRIM
FLASHING
1/2" CEMENT BD TRIM
w/ DRIP-STRIP
4 1/2" (R-25) RIGID INSULATION
5/ 8" PLYWOOD SHEATHING
TREATED 2x6 WOOD BLOCKING w/ ANCHOR BOLT
MASONRY REINF- REFER
TO STRUCTURAL
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
2 1/2" (R-9.5) RIGID
INSULATION
1/2" PLYWOOD NAILER ON
WOOD FURRING @ 24" OC
ASPHALT ROOF SHINGLES ON
SYNTHETIC UNDERLAYMENT
DAMPPROOFING
ON 8" CMU
BLOCKING PER JOIST
MANUFACTURER
JOIST CONNECTION BY
JOIST MANUFACTURER1/2" EXTERIOR
GYPSUM BD SOFFIT
ALUM WRAP OVER 3/4"
PLYWOOD SHEATHING
EAVE FLASHING OVER
TREATED 2x6 FASCIA
SEALANT AROUND
WINDOW FRAME
STEEL LINTEL- SEE
STRUCTURAL
1/2" CEMENT BD TRIM
w/ DRIP-STRIP
SEALANT AROUND
WINDOW FRAME
METAL CLAD WOOD WINDOW,
SEE WINDOW SCHEDULE
HANGAR SPACING @
48" OC MAX
1 1/2" COLD ROLLED
CHANNELS @ 48" OC MAX
FURRING CHANNELS
@ 24" OC
1/2" GYPSUM BOARD 1x3 FIBER CEMENT
WINDOW TRIM
2 1/2" (R-9.5) RIGID
INSULATION
TREATED 2x6 WOOD BLOCKING w/
ANCHOR BOLT
4 1/2" (R-25) RIGID INSULATION
5/ 8" PLYWOOD SHEATHING
1/2" PLYWOOD NAILER ON
WOOD FURRING @ 24" OC
ASPHALT ROOF SHINGLES ON
SYNTHETIC UNDERLAYMENT
ALUM WRAP OVER 3/4"
PLYWOOD FASCIA
EAVE FLASHING OVER
TREATED 2x6 FASCIA
1/2" EXTERIOR
GYPSUM BD SOFFIT
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
FLASHING
I-JOIST- SEE STRUCTURAL
MASONRY REINF- REFER
TO STRUCTURAL
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
2 1/2" (R-9.5) RIGID
INSULATION
DAMPPROOFING
ON 8" CMU
TREATED RAKE WALL
FRAMING ABOVE CMU
4 1/2" (R-25) RIGID INSULATION
5/ 8" PLYWOOD SHEATHING
1/2" PLYWOOD NAILER ON
WOOD FURRING @ 24" OC
ASPHALT ROOF SHINGLES ON
SYNTHETIC UNDERLAYMENT
RAKE FLASHING
ALUM WRAP OVER
TREATED (2) 2 x 8
FASCIA BOARD
DOOR LINTEL- SEE
STRUCTURAL
FIBER CEMENT SIDING
ON TREATED WOOD
FURRING @ 24" OC
2 1/2" (R-9.5) RIGID
INSULATION
1x3 FIBER CEMENT
WINDOW TRIM
FLASHING
COILING DOOR HOOD
1/2" CEMENT BD TRIM
w/ DRIP-STRIP
DOOR LINTEL- REFER TO
STRUCTURAL
HANGAR SPACING @
48" OC MAX
1 1/2" COLD ROLLED
CHANNELS @ 48" OC MAX
FURRING CHANNELS @
24" OC
1/2" GYPSUM BOARD
5/8" GYPSUM BD
EA.SIDE ON 3-5/8"
METAL STUDS @
24" OC
FRP DOOR & FRAME
8" CMU
A1
SCALE: 1-1/2" = 1'-0"
WALL SECTION
A301A101
CAUTION:
IF THIS DRAWING IS A REDUCTION,
USE THE GRAPHIC SCALES.
1 1/2"=1'-0" 210.50
C2
SCALE: 1-1/2" = 1'-0"
WALL SECTION
A301A101 C3
SCALE: 1-1/2" = 1'-0"
WALL SECTION
A301A101
B2
SCALE: 1-1/2" = 1'-0"
WALL SECTION
A301A101
SECTIONS
A302
WALL
A2
SCALE: 1-1/2" = 1'-0"
WALL SECTION
A301A101
A2
SCALE: 1-1/2" = 1'-0"
WALL SECTION
A301A101
18905.002
12-16-2021
FINAL SUBMISSION
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D
The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DESIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
STAMP:
ELECTRICAL LEGEND ABBREVIATIONS
S M
S MP
S a
,, , ,S S 2 S 3
S 4
S WP
S MC
S OS
F
J J
M
CB
GFI
SYMBOL DESCRIPTION
LIGHTING FIXTURE - TYPE AS INDICATED
SWITCH - SINGLE POLE, DOUBLE POLE, THREE WAY, FOUR
WAY, SUBSCRIPT DENOTES OUTLETS CONTROLLED
- MOUNTING HEIGHT 4'-0"
SWITCH - OCCUPANY SENSOR, MOMENTARY CONTACT,
WEATHER PROOF - MOUNTING HEIGHT 4'-0"
JUNCTION BOX - CEILING, WALL MOUNTED - SIZE PER NEC
OR AS INDICATED
DISCONNECT SWITCH - FUSED, NON-FUSED - TYPE AND
RATING AS INDICATED
MANUAL MOTOR STARTER, H.P. RATED SWITCH, H.P. RATED
SWITCH WITH PILOT LIGHT - MOUNTING
HEIGHT 4'-0" - TYPE AND RATING AS REQUIRED
MOTOR - HORSEPOWER AS NOTED
DUPLEX RECEPTACLE - 20A., 125V. - MOUNTING HEIGHT
18" UNLESS NOTED OTHERWISE
GFI RECEPTACLE - 20A., 125V. - MOUNTING HEIGHT 18"
UNLESS NOTED OTHERWISE
HOMERUN TO PANEL - NUMBER OF ARROWS INDICATE
CONDUIT - IN OR UNDER FLOOR
CONDUIT - IN OR ON CEILING OR WALLS
TO TOP
PANELBOARD - TYPE AS NOTED - MOUNTING HEIGHT 6'-6"
ENCLOSED CIRCUIT BREAKER
NUMBER OF CIRCUITS AND NUMBER OF CROSSLINES
INDICATES NUMBER OF #12 PHASE & NEUTRAL
CONDUCTORS - WHERE NO CROSSLINES APPEAR
2#12 CONDUCTORS ARE IMPLIED. GROUND WIRE IS
NOT SHOWN BUT REQUIRED. PROVIDE #12 GROUND
WIRE UNLESS OTHERWISE INDICATED.
1. ALL WIRE SIZES SHOWN ARE FOR COPPER CONDUCTORS.
2. DO NOT ROUTE CONDUIT EXPOSED ON BUILDING EXTERIOR. CONDUIT SHALL
ENTER BUILDING AT CLOSEST POINT OF USAGE SERVING EXTERIOR EQUIPMENT
UNLESS OTHERWISE INDICATED.
3. AMPACITY FOR CONDUCTORS 100 AMPS AND LESS SHALL BE BASED ON THE 60
DEGREE C AMPACITY RATING AS DEFINED BY THE NATIONAL ELECTRICAL CODE.
CONDUCTORS FOR AMPACITIES GREATER THAN 100 AMPS SHALL BE BASED ON
THE 75 DEGREE C RATING AS DEFINED BY THE NATIONAL ELECTRICAL CODE.
4. ELECTRICAL EQUIPMENT SUITABLE FOR EXTERIOR USE SHALL BE NEMA 3R RATED
UNLESS OTHERWISE INDICATED.
5. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES IN FORCE AT THE TIME OF
CONSTRUCTION.
6. PROVIDE EQUIPMENT REQUIRING AIR CIRCULATION WITH THE CLEARANCE
REQUIRED BY THE MANUFACTURER UNLESS OTHERWISE INDICATED.
7. ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL EQUIPMENT
INSTALLATION WITH OTHER TRADES.
8. FEEDER TAPS TO PARALLEL CONDUCTORS SHALL TAP ALL PARALLEL
CONDUCTORS.
9. FOR PARALLEL CONDUCTORS, DO NOT RUN ALL OF THE SAME PHASES IN A SINGLE
CONDUIT. EACH PARALLELED CONDUIT SHALL CONSIST OF ALL THREE PHASE
WIRES, NEUTRAL AND GROUND, AS APPLICABLE.
10. THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS AND
ELEVATIONS OF EXISTING WORK PRIOR TO FABRICATION AND INSTALLATION OF
NEW MATERIAL.
11. THE CONTRACTOR SHALL SATISFY THEMSELVES AS TO THE LOCATION OF
EXISTING UTILITIES.
12. THE CONTRACTOR SHALL EXERCISE CARE WHEN WORKING NEAR AREAS THAT ARE
EXISTING TO REMAIN. IF THE CONTRACTOR DAMAGES ANY OF THOSE AREAS
DURING THE COURSE OF CONSTRUCTION, REPAIR IN-KIND WITHOUT CHARGE TO
THE OWNER.
13. A SEPARATE GROUND AND NEUTRAL WIRE SHALL BE RUN WITH EACH FEEDER AND
BRANCH CIRCUIT. GROUND WIRE SHALL BE SIZED AS REQUIRED BY THE NATIONAL
ELECTRICAL CODE, UNLESS OTHERWISE INDICATED.
14. WHERE CIRCUIT BREAKERS ARE ADDED TO EXISTING PANELBOARDS, CIRCUIT
BREAKERS SHALL MATCH THE PANELBOARD'S AIC RATING.
15. ALL CIRCUIT BREAKERS SERVING HVAC EQUIPMENT SHALL BE HACR TYPE.
16. PROVIDE AN UNGROUNDED CONDUCTOR (NEUTRAL) TO ALL LIGHTING CONTROL
SWITCH LOCATIONS. TERMINATE WIRE FOR FUTURE USE IF NOT USED FOR THE
CURRENT PROJECT.
17. COORDINATE EXACT LOCATION AND MOUNTING HEIGHTS OF ALL DEVICES WITH
ARCHITECTURAL DRAWINGS PRIOR TO INSTALLATION.
GENERAL NOTES: (APPLY TO ALL ELECTRICAL DRAWINGS)
A
AC
AFF
AIC
BKR
C
CB
CLG
C
CT
CU
DISC
DN
DWG
EF
EX
F
FDR
FLA
GFI
GRD
HP
HZ
JB
KCMIL
KVA
KW
LF
LTG
MAX
M.H.
MIN
MISC
MLO
MTD
NC
NEC
NF
NIC
NL
NO.,#
N.O.
O/C
OH
P
PVC
SF
SPECS
TYP
UG
UH
UL
V W W/
WP
XFMR
AMPERE
ALTERNATING CURRENT
ABOVE FINISHED FLOOR
AMPERES INTERRUPTING CAPACITY
BREAKER
CONDUIT
CIRCUIT BREAKER
CEILING
CENTER LINE
CURRENT TRANSFORMER
COPPER
DISCONNECT
DOWN
DRAWING
EXHAUST FAN
EXISTING
FUSED OR FUSIBLE
FEEDER
FULL LOAD AMPERES
GROUND FAULT INTERRUPTER
GROUND
HORSEPOWER
HERTZ
JUNCTION BOX
THOUSAND CIRCULAR MILS
KILO-VOLTS-AMPERES
KILOWATTS
LINEAR FEET
LIGHTING
MAXIMUM
MOUNTING HEIGHT
MINIMUM
MISCELLANEOUS
MAIN LUGS ONLY
MOUNTED
NORMALLY CLOSED
NATIONAL ELECTRICAL CODE
NON-FUSED
NOT IN CONTRACT
NIGHT LIGHT
NUMBER
NORMALLY OPEN
ON CENTER
OVERHEAD
POLE (1P., 2P., 3P.)
POLYVINYL CHLORIDE
SQUARE FOOT
SPECIFICATIONS
TYPICAL
UNDERGROUND
UNIT HEATER
UNDERWRITERS LABORATORIES
VOLTS
WATTS
WITH
WEATHERPROOF
TRANSFORMER
L
- MOUNTING HEIGHT 18" UNLESS NOTED OTHERWISE
- TYPE AS INDICATED OR SCHEDULED
SPECIAL PURPOSE RECEPTACLE - WALL MOUNTED
E
EMERGENCY LIGHT - REMOTE HEADS - TYPE AS INDICATED
LOW VOLTAGE, D.C., EMERGENCY WIRING SYSTEM
- 2#10-3/4"C., UNLESS OTHERWISE NOTED
EXIT LIGHT - CEILING, WALL MOUNTED - SHADED AREA
INDICATES ILLUMINATED FACE - PROVIDE
DIRECTIONAL ARROWS AS INDICATED
- WALL MOUNTING HEIGHT 7'-6"
OCCUPANCY SENSOR WITH DUAL TECHNOLOGY SENSORS
- CEILING MOUNTED.
CONTROL DEVICE - POWER/RELAY PACK
OS OCCUPANCY SENSOR
SPLIT DUPLEX RECEPTACLE - 20A., 125V. - MOUNTING HEIGHT
18" UNLESS NOTED OTHERWISE - FACEPLATE SHALL
CONDUIT - UNDERGROUND ELECTRICE
EB ELECTRIC HANDHOLE / PULL BOX - 18" x 18" x 18".
MAINTAIN SERVICE LOOP WITHIN HANDHOLE.
IDENTIFY THE CONTROLLED OUTLET.
18905.002 12-16-2021
FINAL SUBMISSION
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DEGIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
STAMP:
E01
ELECTRICAL LEGENDS,
ABBREVIATIONS & NOTES
KAW
FJL
GFI
PANELBOARD 'L'
SS
L-8
MC
MC
GFI
GFI
PTAC-1
208V, 1Ø,
27.5 MCA
EUH-1
208V, 3Ø, 7.5 kW.
NEMA 6-30R
MM
S M
EE
GFI
A
A Y
X Y
X
L-1,3 L-5
L-2,4,6
J
L-17 L-12
OS
J
S
DIESEL FUEL PUMP
120V, 5.8 FLA, 14 HP
L-11
M
WP
EF-1
120V, 1Ø, 12 HP.
J J S M S M
L-18L-16
BB
A
A
A
A
GARAGE
OFFICE
S
GFI
WP
GFI
WP
L-7
BB
OS
OS
(APPLY TO THIS SHEET ONLY)DRAWING NOTES:
EQUIPMENT DISCONNECT MEANS SHALL BE FURNISHED BY
THE EQUIPMENT SUPPLIER, INSTALLED AND WIRED BY THE
ELECTRICAL CONTRACTOR.
PROVIDE 3P-100A CIRCUIT BREAKER IN SERVICE ENTRANCE
PANEL LOCATED BEHIND BUILDING "B12 - COIL CONTROL"
TO REPLACE THE EXISTING CIRCUIT BREAKER FEEDING "B9
- BATTERY HOUSE". PROVIDE TWO SETS OF (4 #2/0 & 1 #3
GROUND WIRE IN 2" CONDUIT) FROM EXISTING SERVICE
PANEL TO PANELBOARD "L", APPROXIMATELY 550'. DIRECT
BURY AT A MINIMUM OF 24" FROM TOP OF CONDUIT. SEE
DRAWING E03 FOR ADDITIONAL INFORMATION
3 #10, 1 #10 GROUND WIRE IN 3/4" CONDUIT.
CONNECTION TO OVERHEAD COILING DOOR AND CONTROL
SWITCH. COORDINATE EXACT REQUIREMENTS WITH
EQUIPMENT MANUFACTURER AND EXACT LOCATION WITH
ARCHITECT.
INSTALL UNDER CLASS I, DIVISION 2 REQUIREMENTS.
PROVIDE CONDUIT WITH EXPLOSION-PROOF REDUCER
SEAL AT BOTH POINTS OF EMERGENCE ABOVE GRADE.
2 #10, 1 #10 GROUND WIRE IN 3/4" CONDUIT.
(APPLY TO THIS SHEET ONLY)GENERAL NOTES:
1. COORDINATE FINAL WIRING DEVICE LOCATIONS WITH
ARCHITECT/ EQUIPMENT LOCATIONS.
2. NO SURFACE MOUNTED CONDUIT OR JUNCTION BOXES
ALLOWED WITHIN THE BUILDING.
18905.002 12-16-2021
FINAL SUBMISSION
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DEGIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
STAMP:
E02
ELECTRICAL PLAN
ROOM PLAN - ELECTRICAL WORK
KAW
FJL
0 2' 4' 8' 12' 1/4"=1'-0"
IF THIS PLAN IS A REDUCTION, GRAPHIC
SCALES MUST BE USED.
GRAPHIC SCALE
CAUTION:
SCALE: 14" = 1'-0"
NOT TO SCALE
LIGHTING CONTROL NOTES:
1. DO NOT ATTEMPT TO POWER MORE THAN 4 DEVICES, BE IT SENSORS
OR AUXILLARY PACKS, FROM A SINGLE POWER PACK.
2. LOADS ARE AUTO ON / AUTO OFF.
3. THE RECOMMENDED LOW VOLTAGE WIRE IS 18AWG.
4. ONLY ONE POWER PACK PER ROOM IS SHOWN FOR CLARITY. USE
ADDITIONAL POWER PACKS IF MORE THAN 4 DEVICES ARE SHOWN ON
PLANS.
5. OCCUPANCY SENSORS SHALL BE SET FOR 20 MINUTE TIME-OUT DELAY.
LIGHTING CONTROL DIAGRAM
N
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.SIDED
BLDG
EX.SIDED
BLDG
EX TRANSFORMER
EX GENERATOR
EX BUILDING "B9 - BATTERY HOUSE"
EX BUILDING "B12 - COIL CONTROL"
TESLA ROAD
EX. ELEC EQUIPMENT
(C/T,TRANSFER SWITCH,
DISTRIBUTION PANEL)
ON KINDORF RACK
E
E
E
E
E
E
E
E
5' MINIMUM FROM ROAD
E
E E
E E
E
18905.002 12-16-2021
FINAL SUBMISSION
WOODFORD, VA 22580
4270 TESLA ROAD
A
B
2 3
C
D
1 2 3
4 5
4 5
PROJECT:
CONSULTANTS:
C
EBL ENGINEERS, LLC
MECHANICAL * ELECTRICAL * FIRE PROTECTION
8005 Harford Road, Baltimore, Maryland 21234-5701
D The Professional Engineering Center e-mail ebl@eblengineers.com
(410) 668-8000 FAX (410) 668-8001
B
A
SHEET TITLE
CHECKED BY:
MARK
PROJECT NO:
DATE:
DRAWN BY:
ISSUE:
DATE DESCRIPTION
DEGIGN OF SHOP/GARAGE
USGS FREDERICKSBURG
MAGNETIC OBSERVATORY
WHITNEY BAILEY COX & MAGNANI, LLC
300 East Joppa Road Suite 200
Baltimore, MD 21286
410.512.4500 www.wbcm.com
WBCM
STAMP:
E03
ELECTRICAL SITE PLAN
KAW
FJL
0 15' 30' 60' 90' 1'=30'-0"
IF THIS PLAN IS A REDUCTION, GRAPHIC
SCALES MUST BE USED.
GRAPHIC SCALE
CAUTION:
ELECTRICAL SITE PLAN
SCALE: 1" = 30'-0"
N
(APPLIES TO THIS SHEET ONLY)DRAWING NOTES:
TWO SETS OF (4 #2/0 & 1 #3 GROUND WIRE IN 2" CONDUIT).
DIRECT BURY AT A MINIMUM OF 24" FROM TOP OF CONDUIT.
MAKE CONNECTION TO PANELBOARD "L". SEE SHEET E02
FOR ADDITIONAL INFORMATION.
| Architectural Signed.pdf |
| 2016101404-A101 |
| Sheets and Views |
| Floor & Roof Plans |
| 2016101404-A201 |
| Sheets and Views |
| Exterior Elevations |
| 2016101404-A301 |
| Sheets and Views |
| Building Sections |
| 2016101404-A302 |
| Sheets and Views |
| Wall Sections |
| Electrical Signed.pdf |
| Sheets and Views |
| 18905.002 E01-E01 |
| 18905.002 E02-E02 |
| 18905.002 E03-E03 |
| Electrical Signed.pdf |
| Sheets and Views |
| 18905.002 E01-E01 |
| 18905.002 E02-E02 |
| 18905.002 E03-E03 |
File details come from the government source that posted it. Updated .