- Solicitation number
- FA441824Q0088
About this file
This document outlines the salient characteristics for a federal contract opportunity solicited by the Department of the Air Force Air Mobility Command (AMC) under Solicitation Number FA441824Q0088. The contract requires the provision of:
(A) 92 cubic yards of 4000 psi concrete with 2-6 inch slump
(B) 500 cubic yards of 3/4 minus standard road type graded aggregate base course (GABC)
(C) 400 cubic yards of sand/clay mixture fill
(D) 1,300 feet of silt fence
(E) 200 stakes at 1/2x2x36 inches
(F) 100 stakes at 2x2x6 inches
(G) 7,500 square feet of 6x6 - 8 / 8 - W2.1 X W2.1 reinforcing wire mesh
(H) 1,500 Concrete Forming Plastic Rebar Chairs at 3.875" - 4" tall
The products and services support the Air Force's Air Mobility Command (AMC) training requirements, including hosting mission training for 2 medium sized structures and 3 small sized structures to support Ready Airman Training (RAT) courses.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SALIENT CHARACTERISTICS
ATSO YARD SITE DEVELOPMENT
I. GENERAL OVERVIEW.
This memo outlines the salient characteristics for: (A) ninety-two (92) cubic yards of concrete 4000 psi between 2-6 slump; (B) five-hundred (500) cubic yards of graded aggregate base course (GABC) 3/4 minus standard road type; (C) four hundred (400) cubic yards of fill, sand/clay mixture; (D) One thousand three-hundred (1300) feet of silt fence; (E) two-hundred (200) stakes, 1/2x2x36; (F) one-hundred (100) stakes, 2x2x6; (G) seven thousand five-hundred (7,500) square feet of reinforcing wire mesh, 6x6 - 8 / 8 - W2.1 X
W2.1; (H) one thousand five-hundred (1500) Concrete Forming Plastic Rebar Chair, 3.875" - 4" Tall.
II. SPECIFICATIONS.
At a minimum the equipment and accessories shall possess the following specifications:
(A) Ninety-two (92) cubic yards of concrete.
Specifications for the concrete shall be 4000 psi between a 2-6 slump.
(B) Five-hundred (500) cubic yards of graded aggregate base course (GABC)
Specifications for the GABC shall be 3/4 minus standard road type
(C) Four hundred (400) cubic yards of soil fill
Specifications for the fill shall be a sand/clay mixture
(D) One thousand three-hundred (1300) feet of silt fence
(E) Two-hundred (200) stakes, 1/2x2x36
Specifications for the stakes shall be 1/2x2x36
(F) One-hundred (100) stakes, 2x2x6
Specifications for the stakes shall be 2x2x6
(G) Seven thousand five-hundred (7,500) square feet of reinforcing wire mesh
Specifications for the wire mesh shall be 6x6 - 8 / 8 - W2.1 X W2.1
(H) One thousand five-hundred (1500) Concrete Forming Plastic Rebar Chair
Specifications for the rebar chairs shall be 3.875" - 4" Tall.
III. COMPLIANCE AND STANDARDS:
Ensure that the materials comply with relevant industry standards and regulations, including but not limited to:
American Concrete Institute (ACI)
American Society of Civil Engineers (ASCE)