Attachment_2_Drawings_-_Hoh_Fiber_Optic_Trenching.pdf

PDF 10 MB Posted

Attached to
Installation of Fiber Optic Cable, HOH RAin Forest
Solicitation number
140P8324B0002
Issued by

About this file

The provided document appears to be Attachment 2 - Drawings for the Hoh Fiber Optic Trenching requirement under Solicitation Number 140P8324B0002, issued by the Department of the Interior National Park Service Pacific West Region.

This solicitation is for the trenching and installation of single-mode fiber optic cable in conduit with all necessary appurtenances in the Hoh Rain Forest. The work includes providing all labor, equipment, and materials required to complete the fiber optic cable installation. No specific pricing terms, set asides, award dates, or incumbent information is provided in this attachment. This document appears to be solely the technical drawings outlining the locations and specifications for the required fiber optic cable installation work.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET SUB SHEET TITLE OF SHEET

1 G0 COVER SHEET

2 G1 GENERAL NOTES

3 G2 1968 EXISTING UTILITIES

4 G3 1992 SEWER AS-BUILT

5 G4 TRENCHING OVERVIEW

6 C1 VISITOR CENTER ELEVATION

7 C2 VISITOR CENTER TERMINATION

8 C3 WEST TRENCH ALIGNMENT

9 C4 CENTRAL TRENCH ALIGNMENT

10 C5 HOUSING TERMINATION

11 C6 EAST TRENCH ALIGNMENT

12 C7 RANGER STATION TERMINATION

13 C8 RANGER STATION ELEVATION

14 C9 TRENCH & VAULT DETAILS

15 C10 POST & NETWORK DETAILS

16 T1 PATCH PANEL WIRING DIAGRAM

UNITED STATES

DEPARTMENT OF THE INTERIOR

TITLE OF PROJECT

HOH FIBER OPTIC TRENCHING

DRAWING NO.

_149_

193,315

NATIONAL PARK SERVICE

OLYMPIC NATIONAL PARK

LOCATION WITHIN PARK

HOH RAIN FOREST

PMIS/PKG NO.

XXXXXX

REGION COUNTY STATE

PACIFIC WEST JEFFERSON WASHINGTON

SHEET

_1_ OF _16_

GENERAL NOTES

1. ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH NPS STANDARDS, THE

LATEST WASHINGTON STATE (WSDOT) STANDARD SPECIFICATIONS FOR ROAD,

BRIDGE AND MUNICIPAL CONSTRUCTION, AND RELEVANT REQUIREMENTS OF

ANSI/TIA/EIA, NECA/NEIS & lSO/IEC FOR A STRUCTURED COMMUNICATIONS

SYSTEM (IN ADDITION TO OTHER STATE AND LOCAL STANDARDS).

2. CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND

PROTECTION OF EXISTING UTILITIES. CONTACT DIG ALERT AND FIELD VERIFY

ALL UTILITIES PRIOR TO EXCAVATION. CONTRACTOR SHALL BE RESPONSIBLE

FOR MAINTAINING ALL LOCATE MARKS ONCE UTILITIES HAVE BEEN LOCATED.

3. DIMENSIONS SHOWN ON PLANS ARE TO BE USED BY CONTRACTOR TO

DETERMINE APPROXIMATE FIELD CONDITIONS. PRIOR TO CONSTRUCTION,

CONTRACTOR SHALL FIELD VERIFY EXISTING LOCATIONS, ELEVATIONS,

MATERIAL TYPES, DIAMETER OF PIPES, ETC. OF ALL UTILITIES AND FEATURES

WHERE PROPOSED IMPROVEMENTS CONNECT.

4. EXISTING FACILITIES, INCLUDING BUT NOT LIMITED TO ROADS, WALKWAYS,

SIGNAGE, STRUCTURES, AND UTILITIES DAMAGED BY CONTRACTOR’S

OPERATIONS SHALL BE RESTORED TO MATCH ORIGINAL PRE-CONSTRUCTION

CONDITION WITHOUT ADDITIONAL COST.

5. ALL DISTURBED ASPHALT, CONCRETE, GRAVEL ROADS, GRASS, DRAINAGE

PATTERNS, ROADSIDE DITCHES, TRAILS AND GRADE SHALL BE RESTORED TO

ITS ORIGINAL CONDITION OR AS CALLED FOR IN THE CONTRACT DOCUMENTS,

WHICHEVER IS MORE STRINGENT.

6. CONTRACTOR SHALL FURNISH AND INSTALL EVERYTHING REQUIRED TO

PROVIDE COMPLETE AND OPERABLE FACILITIES AS SHOWN HEREIN. IF THERE

IS AN OMISSION ON THE CONSTRUCTION DOCUMENTS, SUCH OMISSION

SHALL NOT BE CONSTRUED TO MEAN THAT THE CONTRACTOR IS NOT

REQUIRED TO FURNISH OR PROVIDE EVERYTHING THAT IS NECESSARY TO

PROVIDE COMPLETE AND OPERABLE FACILITIES.

7. EQUIPMENT USED ONSITE SHALL BE PRESSURE CLEANED AND FREE OF WEEDS,

SEED, DEBRIS AND MUD TO PREVENT INTRODUCTION AND/OR SPREAD OF

EXOTIC, INVASIVE PLANTS. EQUIPMENT SHALL BE INSPECTED DAILY FOR

LEAKS, AND NECESSARY REPAIRS SHALL BE MADE PRIOR TO OPERATION.

8. ALL CONTRACTORS WORKING WITH THE PROJECT BOUNDARIES ARE RESPONSIBLE

FOR COMPLIANCE WITH ALL APPLICABLE SAFETY LAWS, INCLUDING REQUIRED

TRENCH SHORING. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL EMPLOYEES

AND/OR SUBCONTRACTORS WITH PERSONAL PROTECTIVE EQUIPMENT AND

FOLLOWING ALL SAFETY PROTOCOLS.

9. TRENCH EXCAVATION, BEDDING AND BACKFILL SHALL BE ACCOMPLISHED IN

ACCORDANCE WITH WSDOT SECTION 7-08. TRENCH SHALL BE KEPT FREE FROM

WATER UNTIL JOINTING IS COMPLETE. CONTRACTOR SHALL MAINTAIN SUFFICIENT

PUMPING EQUIPMENT ON THE JOB TO ENSURE THESE PROVISIONS ARE CARRIED

OUT.

10. ALL COSTS INCURRED IN CORRECTION OF DEFICIENT WORK SHALL BE THE

RESPONSIBILITY OF THE CONTRACTOR.

11. CONSTRUCTION FENCING OR BARRIERS SHALL BE PROVIDED WHERE NECESSARY,

INCLUDING AROUND OPEN EXCAVATIONS WHEN WORK IS NOT ACTIVELY IN

PROGRESS, TO PREVENT THE PUBLIC FROM ENTERING WORK AREAS.

12. UNLESS OTHERWISE INDICATED, DEMOLISHED MATERIALS BECOME THE PROPERTY

OF THE CONTRACTOR. COMPLY WITH EPA REGULATIONS AND DISPOSAL

REGULATIONS OF AUTHORITIES HAVING JURISDICTION.

13. ARCHAEOLOGICAL MONITORING IS REQUIRED. PROVIDE THREE WEEKS NOTICE PRIOR

TO CONSTRUCTION START DATE.

14. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL FOR ALL WORK CONDUCTED

WITHIN THE ROAD CORRIDOR. CONTRACTOR SHALL ENSURE ONE LANE REMAINS

OPEN AND ACCESSIBLE FOR TRAVEL AT ALL TIMES.

DESIGNED:

K. COOK

SUB SHEET NO. TITLE OF SHEET

GENERAL NOTES

DRAWING NO.

_149_

193,315

TECH REVIEW:

G1 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

_2_ OF _16_

DESIGNED:

K. COOK

SUB SHEET NO. TITLE OF SHEET

1968 EXISTING UTILITIES

DRAWING NO.

_149_

193,315

TECH REVIEW:

G2 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

_3_ OF _16_

SUB SHEET NO. TITLE OF SHEET

1992 SEWER AS-BUILT

DRAWING NO.

_149_

193,315

TECH REVIEW:

G3 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

_4_ OF _16_

SUB SHEET NO. TITLE OF SHEET

TRENCHING OVERVIEW

DRAWING NO.

_149_

193,315

TECH REVIEW:

G4 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_5_ OF _16_

VISITOR

CENTER

MAINTENANCE

SHOP

RANGER

STATION

HOUSING

LEGEND:

FIBER OPTIC TRENCH

4’X4’X4’ H-20 FIBER VAULT WITH 12-PORT PATCH PANEL

STARLINK SATELLITE POST WITH ENCLOSURE

ELECTRICAL TRENCH

SUB SHEET NO. TITLE OF SHEET

VISITOR CENTER ELEVATION

DRAWING NO.

_149_

193,315

TECH REVIEW:

C1 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_6_ OF _16_

4” CONDUIT

2” CONDUIT

14 x 19 x 12

HDPE PULL BOX

INSTALL 6-PORT ST

FIBER PATCH

PANEL

APPROXIMATE

LOCATION OF

CONDUIT

PENETRATION

UNDER RAFTERS

APPROXIMATE

LOCATION OF

CONDUIT ROUTED

THROUGH ATTIC &

INTO MECHANICAL

ROOM VIA OPEN

ACCESS HATCH

NOTES:

1. TRANSITION FROM 4” HORIZONTAL (UNDERGROUND)

CONDUIT TO 2” VERTICAL CONDUIT VIA 14” X 19” X

12” HDPE PULL BOX LOCATED AT SOUTHWEST

CORNER OF VISITOR CENTER.

2. SUPPORT 2” CONDUIT AT INTERVALS NO LESS THAN

3’. ROUTE CONDUIT VERTICALLY AT SOUTHWEST

CORNER, THEN NORTH UNDERNEATH RAFTERS TO

PENETRATE ATTIC SPACE. EXTERIOR CONDUIT SHALL

BE PAINTED IN COLOR ‘BEACHWOOD’ TO MATCH

EXISTING SIDING.

3. ROUTE CONDUIT THROUGH ATTIC SPACE TO

TERMINATE AT ACCESS HATCH ON NORTH WALL OF

VISITOR CENTER MECHANICAL ROOM.

4. TERMINATE FIBER WITH 10’ OF SLACK COILED IN

ATTIC SPACE AND ONE ST SINGLE MODE CONNECTOR

PAIR CONNECTED TO NEW 6-PORT ST FIBER PATCH

PANEL, MOUNTED ON WALL.

ACCESS HATCH

SUB SHEET NO. TITLE OF SHEET

VISITOR CENTER TERMINATION

DRAWING NO.

_149_

193,315

TECH REVIEW:

C2 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_7_ OF _16_

NOTES:

1. SEE SUB SHEET NO. C1 FOR

WEST ELEVATION OF

VISITOR CENTER

2. TRENCH ALIGNMENT SHALL

FOLLOW WATER LINE

ALIGNMENT, AS INDICATED

BY PATCHED UTILITY CUTS

IN ASPHALT

MATCH TO WEST TRENCH

ALIGNMENT – SUB SHEET NO. C3

14 x 19 x 12

HDPE PULL BOX

MECHANICAL

ROOM

ROAD CUTS

INDICATING WATER

LINE TRENCH

SUB SHEET NO. TITLE OF SHEET

WEST TRENCH ALIGNMENT

DRAWING NO.

_149_

193,315

TECH REVIEW:

C3 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_8_ OF _16_

MATCH TO VISITOR CENTER

TERMINATION – SUB SHEET NO. C2

FOLLOW EXISTING

WATER LINE ALIGNMENT

& ROAD CUTS

CUT & REPLACE

CONCRETE CURB

MATCH TO CENTRAL TRENCH

ALIGNMENT – SUB SHEET NO. C4

SUB SHEET NO. TITLE OF SHEET

CENTRAL TRENCH ALIGNMENT

DRAWING NO.

_149_

193,315

TECH REVIEW:

C4 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_9_ OF _16_

NOTES:

1. FOLLOW EXISTING WATER LINE ALIGNMENT AND ROAD CUTS

2. CUT & REPLACE CONCRETE CURB (2 LOCATIONS SHOWN ON SUB SHEET NO. C4)

3. PROTECT IN PLACE OR REMOVE AND REPLACE SIGNAGE IMPACTED BY CONSTRUCTION

LOOKING SOUTH ACROSS RV PARKING

(FOREGROUND) & MAIN ROAD LOOP

LOOKING NORTH TOWARD MAIN ROAD AND PARKING LOOP

FROM HOUSING/RANGER STATION ACCESS ROAD

LOOKING NORTHWEST ALONG HOUSING/RANGER STATION ACCESS ROAD

SUB SHEET NO. TITLE OF SHEET

HOUSING TERMINATION

DRAWING NO.

_149_

193,315

TECH REVIEW:

C5 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_10_ OF _16_

NOTES:

1. TRANSITION FROM 4” HORIZONTAL (UNDERGROUND)

CONDUIT TO 2” VERTICAL CONDUIT VIA 14” X 19” X

12” HDPE PULL BOX LOCATED AT BASE OF POST.

2. INSTALL 1” ELECTRICAL CONDUIT FROM WEATHER

STATION POWER SOURCE TO NEMA 3 RATED

ENCLOSURE ON POST. PROVIDE PULL STRING FOR NPS

TO RUN 120V CONDUCTORS AT FUTURE DATE.

3. MOUNT 18” X 14” X 9” NON-METALLIC NEMA 3

LOCKABLE ENCLOSURE ON POST. TERMINATE 1” & 2”

CONDUITS FROM THE PULL BOX INTO THE

ENCLOSURE BASE. EXTEND ONE 1” CONDUIT FROM

TOP OF ENCLOSURE TO TOP OF POST FOR FUTURE

USE WITH STARLINK SATELLITE CABLE (TO BE

INSTALLED BY NPS).

4. TERMINATE FIBER WITH 2’ OF FREE STRAND (NO

JACKET) SLACK AND ONE ST SINGLE MODE

CONNECTOR PAIR CONNECTED TO NEW 6-PORT ST

FIBER PATCH PANEL, MOUNTED INSIDE ENCLOSURE.

COORDINATE WITH NPS FOR EXACT MOUNTING

LOCATION.

14 x 19 x 12

HDPE PULL BOX

AT BASE OF POST

LEGEND:

FIBER OPTIC TRENCH

STARLINK SATELLITE POST WITH ENCLOSURE

ELECTRICAL TRENCH

SUB SHEET NO. TITLE OF SHEET

EAST TRENCH ALIGNMENT

DRAWING NO.

_149_

193,315

TECH REVIEW:

C6 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_11_ OF _16_

NOTES:

1. PROVIDE AASHTO H-20 LOAD RATED

CONCRETE VAULT WITH COVER. H2 PRE-CAST,

INC. 444 VAULT BASE WITH 440-13 COVER, OR

EQUAL AS APPROVED BY NPS CONTRACTING

OFFICER. SET TOP OF VAULT FLUSH WITH

FINISHED SURFACE.

2. TERMINATE ALL FIBER OPTIC CABLE WITH 10’

OF SLACK PER LINE (COILED AND SECURED

INSIDE VAULT) AND ONE (OR MORE) ST

SINGLE MODE CONNECTOR PAIR CONNECTED

TO NEW 12-PORT ST FIBER PATCH PANEL,

MOUNTED INSIDE VAULT. SEE SUB SHEET NO.

C9 FOR VAULT DETAIL AND E1 FOR PATCH

PANEL WIRING DIAGRAM.

3. NOTE THAT RANGER STATION AND

MAINTENANCE SHOP FIBER OPTIC CONDUIT

SHALL SHARE A TRENCH UNTIL POINT OF

DIVERGENCE.

SUB SHEET NO. TITLE OF SHEET

RANGER STATION TERMINATION

DRAWING NO.

_149_

193,315

TECH REVIEW:

C7 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_12_ OF _16_

MAINTENANCE SHOP

ROUTE THROUGH WEST WALL

OF MAINTENANCE SHOP VIA

EXISTING PENETRATION

14 x 19 x 12

HDPE PULL BOX

RE-USE OR REPLACE EXISTING

1 ½” CONDUIT & PENETRATION

SUB SHEET NO. TITLE OF SHEET

RANGER STATION ELEVATION

DRAWING NO.

_149_

193,315

TECH REVIEW:

C8 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_13_ OF _16_

NOTES:

1. TRANSITION FROM 4” HORIZONTAL (UNDERGROUND) CONDUIT TO EXISTING 1 ½” VERTICAL CONDUIT VIA 14” X 19” X 12” HDPE

PULL BOX LOCATED UNDER PEAK OF RANGER STATION ON WEST SIDE. CAREFULLY CUT AND RE-CONNECT EXISTING 1 ½”

CONDUIT TO PASS THROUGH NEW PULL BOX, OR REPLACE VERTICAL SEGMENT IN-KIND.

2. PROTECT EXISTING ETHERNET CABLE INSIDE EXISTING 1 ½” CONDUIT. CUT EXISTING CONDUIT AND LOCATE PULL BOX SO THAT ETHERNET CABLE CAN BE RE-ESTABLISHED. COORDINATE ETHERNET CABLE OUTAGE WITH NPS CONTRACTING OFFICER.

3. ROUTE CONDUIT THROUGH INTERIOR WOOD CABINET TO TERMINATE AT MEDIA CONVERTER LOCATED INSIDE ENCLOSURE.

4. TERMINATE FIBER WITH 5’ OF SLACK, INCLUDING 2’ OF FREE STRAND (NO JACKET) SLACK, COILED OUTSIDE EXISTING CABINET

AND THREE ST SINGLE MODE CONNECTOR PAIRS CONNECTED TO NEW 6-PORT ST FIBER PATCH PANEL, TO BE MOUNTED BY NPS

INSIDE ENCLOSURE WITH EXISTING MEDIA CONVERTER.

RE-USE OR REPLACE

EXISTING 1 ½” CONDUIT FOR

OPTICAL FIBER

4” CONDUIT 14 x 19 x 12

HDPE PULL BOX

MEDIA CONVERTER

LOCATED INSIDE

ENCLOSURE

SUB SHEET NO. TITLE OF SHEET

TRENCH & VAULT DETAILS

DRAWING NO.

_149_

193,315

TECH REVIEW:

C9 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_14_ OF _16_

4” M

IN

2” MIN. BEDDING

A TRENCH & CONDUIT DETAIL

C9 N.T.S.

VA

RI

ES

8”

M

IN

B H-20 CONCRETE VAULT SECTIONS & PLAN

C9 N.T.S.

INSTALL MAGNETIC 3” WIDE

DETECTABLE TAPE 12” ABOVE

CONDUIT

NOTES:

1. CONCRETE 28 DAY COMPRESSIVE STRENGTH

4,500 PSI.

2. REBAR ASTM A-615 GRADE 60, MESH ASTM A-

185 GRADE 65.

3. ASTM C-857 MINIMUM STRUCTURAL DESIGN

LOADING FOR UNDERGROUND PRECAST

CONCRETE STRUCTURES.

4. H-20 LOAD RATING FOR INCIDENTAL TRAFFIC.

5. GROUT TO FULL WALL THICKNESS AROUND

PIPES AT KNOCKOUTS.

10 CF OF 1” TO 1 ½”

GRAVEL UNDER SUMP

SUB SHEET NO. TITLE OF SHEET

POST & NETWORK DETAILS

DRAWING NO.

_149_

193,315

TECH REVIEW:

C10 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_15_ OF _16_

A SATELLITE POST DETAIL

C10 N.T.S.

B FIBER OPTIC NETWORK SCHEMATIC DIAGRAM

C10 N.T.S.

NOTES:

1. WOOD SERVICE POST SHALL

BE 25’ MIN (SET 5’MIN INTO

GROUND).

2. SERVICE POST SHALL BE

SOLID (NOT LAMINATED) 6”

X 6” TIMBER, PRESSURE

TREATED FOR GROUND

CONTACT.

3. CONDUIT SHALL BE 1” & 2”

SCH 40 PVC, FASTENED TO

POST AT INTERVALS NOT

GREATER THAN 3’.

4. ALL CONDUIT AND FITTINGS

SHALL BE RAIN-TIGHT.

1” SCH

40 PVC

NEMA 3 NON-

METALLIC ENCLOSURE

18” x 14” x 9”

22” TRENCH DEPTH

TO TOP OF CONDUIT

25’ MIN

5’ MIN

1” & 2” SCH

40 PVC

HDPE LIGHT-DUTY PULL BOX

14” x 19” x 12”

36” RADIUS 90 DEGREE SCH 40

PVC SWEEP ELBOW

NPS TO MOUNT

STARLINK SATELLITE

UNIT TO TOP OF POST

(FUTURE) 120V POWER

(FROM WEATHER

STATION – NPS)

STARLINK UNIT

(W/ SATELLITE

CABLE – NPS)

- 6-PORT ST FIBER

PATCH PANEL

- MEDIA CONVERTER (NPS )

- 120V GFCI RECEPTACLE (NPS)

- STARLINK POWER SUPPLY W/

AC CABLE (NPS)

VISITOR CENTER

6-PORT ST FIBER

PATCH PANEL

RANGER STATION

6-PORT ST FIBER

PATCH PANEL

MAINTENANCE SHOP

6-PORT ST FIBER

PATCH PANEL

12-PORT SINGLE MODE ST

FIBER PATCH PANEL

4’ x 4’ x 4’ H-20 VAULT

NEMA 3 ENCLOSURE

LEGEND:

ST SINGLE MODE CONNECTORS

SUB SHEET NO. TITLE OF SHEET

PATCH PANEL WIRING DIAGRAM

DRAWING NO.

_149_

193,315

TECH REVIEW:

T1 HOH FIBER OPTIC TRENCHING

PMIS/PKG NO.

XXXXXX

DATE:

4/2024

HOH RAIN FOREST, WA

OLYMPIC NATIONAL PARK

SHEET

_16_ OF _16_

LEGEND:

SL STARLINK SATELLITE POST – HOUSING AREA

M MAINTENANCE SHOP – OFFICE CORNER

VC VISITOR CENTER – MECHANICAL ROOM

RS RANGER STATION – OFFICE AREA

ALL CONNECTIONS ON

“OTHER SIDE” OF 6-PORT

PATCH PANELS WILL BE

MADE BY NPS AFTER

FIBER OPTIC TESTING &

ACCEPTANCE

Slide Number 1
GENERAL NOTES
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7
Slide Number 8
Slide Number 9
Slide Number 10
Slide Number 11
Slide Number 12
Slide Number 13
Slide Number 14
Slide Number 15
Slide Number 16

File details come from the government source that posted it. Updated .