Attachment_2_-_Drawings.pdf
PDF 6 MB Posted
- Attached to
- ZION-HOUSING INTERIOR REHABILITATION
- Solicitation number
- 140PS126Q0018
About this file
These are final construction documents for interior replacement work at Watchman Housing locations within Zion National Park under the National Park Service. The project specifications cover kitchen and bathroom renovations across multiple quarters (Quarters 35, 36, 42, and 46), with work scheduled for completion by March 31, 2026.
Kitchen requirements include removal and disposal of existing countertops, cabinets, sinks, drainpipes, garbage disposals, and range hoods. New installations must feature factory-finished knotty alder cabinets with light to medium stain and catalyzed conversion varnish topcoat applied per AWI/AWMAC standards, with brushed nickel hardware and soft-close mechanisms on all doors and drawers. Mid-grade quartz countertops in beige or warm neutral tones with minimal veining shall include a 4-inch matching backsplash, preapproved by the Contracting Officer's Representative (COR). Double-bowl stainless steel undermount kitchen sinks and Moen Sleek pull-down faucets are specified. Bathroom work requires similar cabinet and countertop specifications with undermount porcelain lavatory sinks, Moen Chateau Chrome low-arc faucets, American Standard Champion toilets (1.28 GPF), and Broan NU-Tone exhaust fans. Flooring includes Engineered Floors Pure Color carpet in Warm Sand for bedrooms and Lyrus Flex Elite luxury vinyl plank flooring in Reef finish for common areas and bathrooms. All measurements require site verification prior to fabrication, with window and fixture protection mandatory throughout construction. Existing flooring adhesives and fasteners shall be removed and disposed of, with subsurfaces leveled per manufacturer specifications. MDF baseboard (5" × 9/16" beveled) is required where complete house replacement is needed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140PS126Q0018_Amd_0002.pdf | ||
| Sol_140PS126Q0018_Amd_0001.pdf | ||
| Attachment_4_-_Hardware_Salient_Characteristics_(Or_Equal).pdf | ||
| Attachment_6_-_WD_UT20260038_5_18_2026.pdf | ||
| Attachment_5_-_Limitations_on_Subcontracting.xlsx | XLSX spreadsheet | |
| Attachment_3_-_Q_A_Document.xlsx | XLSX spreadsheet | |
| Sol_140PS126Q0018.pdf | ||
| Attachment_1_-_Statement_of_Work.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AutoCAD SHX Text
SPRINGDALE
AutoCAD SHX Text
ROCKVILLE
AutoCAD SHX Text
AutoCAD SHX Text
EAST
AutoCAD SHX Text
FORK
AutoCAD SHX Text
VIRGIN
AutoCAD SHX Text
RIVER
AutoCAD SHX Text
COALPITS
AutoCAD SHX Text
WASH
AutoCAD SHX Text
VIRGIN
AutoCAD SHX Text
RIVER
AutoCAD SHX Text
VIRGIN
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
CREEK
AutoCAD SHX Text
LEFT FORK
AutoCAD SHX Text
RIGHT FORK
AutoCAD SHX Text
DEEP
AutoCAD SHX Text
CREEK
AutoCAD SHX Text
GOOSE CREEK
AutoCAD SHX Text
BLUE
AutoCAD SHX Text
SPRINGS
AutoCAD SHX Text
RESERVOIR
AutoCAD SHX Text
KOLOB
AutoCAD SHX Text
RESERVOIR
AutoCAD SHX Text
WASHINGTON CO.
AutoCAD SHX Text
KANE CO.
AutoCAD SHX Text
IRON COUNTY
AutoCAD SHX Text
WASHINGTON COUNTY
AutoCAD SHX Text
WASHINGTON COUNTY
AutoCAD SHX Text
KANE COUNTY
AutoCAD SHX Text
IRON COUNTY
AutoCAD SHX Text
WASHINGTON COUNTY
AutoCAD SHX Text V.C.
AutoCAD SHX Text
KOLOB
AutoCAD SHX Text
CANYONS
AutoCAD SHX Text
ORDERVILLE
AutoCAD SHX Text
CANYON
AutoCAD SHX Text
GREAT
AutoCAD SHX Text
WEST
AutoCAD SHX Text
CANYON
AutoCAD SHX Text
PARUNUWEAP
AutoCAD SHX Text
CANYON
AutoCAD SHX Text
TOWERS
AutoCAD SHX Text
OF THE
AutoCAD SHX Text
VIRGIN
AutoCAD SHX Text
AutoCAD SHX Text
TO
AutoCAD SHX Text
MT. CARMEL
AutoCAD SHX Text
JUNCTION &
AutoCAD SHX Text
AutoCAD SHX Text
TO
AutoCAD SHX Text
AutoCAD SHX Text
TO
AutoCAD SHX Text
& ST. GEORGE
AutoCAD SHX Text
AutoCAD SHX Text
TO CEDAR CITY
AutoCAD SHX Text
KOLOB
AutoCAD SHX Text
CREEK
AutoCAD SHX Text
KOLOB
AutoCAD SHX Text
TERRACE
AutoCAD SHX Text
ROAD
AutoCAD SHX Text
LODGE
AutoCAD SHX Text
ZION
AutoCAD SHX Text
GROTTO
AutoCAD SHX Text
RIVER
AutoCAD SHX Text
VIRGIN
AutoCAD SHX Text
FORK
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
SOUTH
AutoCAD SHX Text
WATCHMAN
AutoCAD SHX Text
ZION CANYON CANYON HEADQUARTERS & MUSEUMMUSEUM
AutoCAD SHX Text
VISITOR CENTER
AutoCAD SHX Text
THIS PROJECT
AutoCAD SHX Text
ZION
AutoCAD SHX Text
NATIONAL
AutoCAD SHX Text
PARK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
UTAH
AutoCAD SHX Text
ARIZONA
AutoCAD SHX Text
NEVADA
AutoCAD SHX Text
ARIZONA
AutoCAD SHX Text
NEVADA
AutoCAD SHX Text
UTAH
AutoCAD SHX Text
MT. CARMEL
AutoCAD SHX Text
JUNCTION
AutoCAD SHX Text
ST. GEORGE
AutoCAD SHX Text
CEDAR
AutoCAD SHX Text
CITY
AutoCAD SHX Text
AutoCAD SHX Text
ALT
AutoCAD SHX Text
AutoCAD SHX Text
PANACA
AutoCAD SHX Text
CALIENTE
AutoCAD SHX Text
AutoCAD SHX Text
MILFORD
AutoCAD SHX Text
AutoCAD SHX Text
PAGE
AutoCAD SHX Text
BRYCE
AutoCAD SHX Text
CANYON
AutoCAD SHX Text N.P.
AutoCAD SHX Text
LAKE MEAD
AutoCAD SHX Text N.R.A.
AutoCAD SHX Text
GRAND
AutoCAD SHX Text
CANYON
AutoCAD SHX Text N.P.
AutoCAD SHX Text
TROPIC
AutoCAD SHX Text
KANAB
AutoCAD SHX Text
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
SPRINGS
AutoCAD SHX Text N.M.
AutoCAD SHX Text
CEDAR
AutoCAD SHX Text
BREAKS
AutoCAD SHX Text N.M.
AutoCAD SHX Text
BASIC DATA:
AutoCAD SHX Text
STATE
AutoCAD SHX Text
NATIONAL PARK SERVICE
AutoCAD SHX Text
DENVER SERVICE CENTER
AutoCAD SHX Text
REGION
AutoCAD SHX Text
COUNTY
AutoCAD SHX Text
DEPARTMENT OF THE INTERIOR
AutoCAD SHX Text
UNITED STATES
AutoCAD SHX Text
LOCATION WITHIN PARK
AutoCAD SHX Text
NAME OF PARK
AutoCAD SHX Text
TITLE OF DRAWING
AutoCAD SHX Text
INTERIOR REPLACEMENT
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
CV
AutoCAD SHX Text
AutoCAD SHX Text
WASHINGTON
AutoCAD SHX Text
UTAH
AutoCAD SHX Text
OF
AutoCAD SHX Text
PKG.
AutoCAD SHX Text
NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text
INTERMOUNTAIN
AutoCAD SHX Text TOPO MAP ISBN-0-915630-08-7 1979; PARK MINI FOLDER 1992; REVISED & REDRAWN 8/93. UPDATED 11/98. SGS.
AutoCAD SHX Text
PMIS: 327856, 336905, 336789
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text
INTERMOUNTAIN
AutoCAD SHX Text TOPO MAP ISBN-0-915630-08-7 1979; PARK MINI FOLDER 1992; REVISED & REDRAWN 8/93. UPDATED 11/98. SGS.
AutoCAD SHX Text
FINAL CONSTRUCTION DOCUMENTS - 03/31/2026
AutoCAD SHX Text
AMPHITHEATER
AutoCAD SHX Text
CAMPGROUND
AutoCAD SHX Text
PICNIC AREA
AutoCAD SHX Text
RANGER STATION
AutoCAD SHX Text
PARK HEADQUARTERS
AutoCAD SHX Text
VISITOR CENTER
AutoCAD SHX Text
HQ.
AutoCAD SHX Text V.C.
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
STATE LINE
AutoCAD SHX Text
UNPAVED ROAD
AutoCAD SHX Text
COUNTY LINE
AutoCAD SHX Text
CREEK OR RIVER
AutoCAD SHX Text
PAVED ROAD
AutoCAD SHX Text
PARK BOUNDARY
AutoCAD SHX Text
%%UINDEX
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NO.
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SUB
AutoCAD SHX Text Quarters 35 Kitchen Elevations and Notes Quarters 35 Half-Bath Elevations and Notes Quarters 35 Bathroom Elevations and Notes Quarters 36 Kitchen Elevations and Notes Quarters 36 Half-Bath Elevations and Notes Quarters 36 Bathroom Elevations and Notes Quarters 42 Kitchen Elevations and Notes Quarters 42 Half-Bath Elevations and Notes Quarters 42 Bathroom Elevations and Notes Quarters 46 Kitchen Elevations and Notes Quarters 46 Half-Bath Elevations and Notes Quarters 46 Bathroom Elevations and Notes Flooring Details and Notes Fixture Details and Notes
AutoCAD SHX Text A1 A1.1 A1.2 A2 A2.1 A2.2 A3 A3.1 A3.2 A4 A4.1 A4.2 A5 A5.1
AutoCAD SHX Text 1 2 3 4 5 6 7 8 9 10 11 12 13 14
AutoCAD SHX Text
SCALE OF MILES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SCALE OF MILES
AutoCAD SHX Text
SCALE OF KILOMETERS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION NATIONAL PARK
6'-9.00"
2'-11.50"
3.50"
2'-2.50"
9'-10.50"
3'-5.00" 3'-5.00"
1'-2.50"
2'-11.50"
3.50"
9'-10.50"
ELEVATION OF WEST KITCHEN WALL
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. MICROWAVE, OVEN, AND FRIDGE TO BE PROPERLY REMOVED AND
STORED IN THE GARAGE FOR REINSTALL.
4. KITCHEN COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES, BRAIDED
LINES, GARBAGE DISPOSALS AND RANGE HOODS TO BE REMOVED
AND DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL DOUBLE-BOWL STAINLESS STEEL KITCHEN
SINK(S), UNDERMOUNT TYPE, WITH EQUAL OR OFFSET
COMPARTMENTS, COMPLETE WITH MOUNTING HARDWARE, SEALANT,
AND REQUIRED ACCESSORIES.
UPPER CABINETS TO BE 12" DEEP
ELEVATION OF EAST KITCHEN WALL
UPPER CABINETS TO BE 12" DEEP
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 35 ELEVATIONS -
AutoCAD SHX Text
KITCHEN EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/24/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A1
2'-1.00"
2'-7.50"
3.50"
ELEVATION OF HALF BATHROOM
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. TOILET TOWEL BARS, AND MIRRORS TO BE PROPERLY PROTECTED IN
PLACE. ANY DAMAGE DONE DURING CONSTRUCTION ILL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR.
4. BATHROOM COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES,
BRAIDED LINES AND TOILETS IN QU42 AND 46 TO BE REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL UNDERMOUNT PORCELAIN LAVATORY SINK(S),
WHITE, WITH INTEGRAL OVERFLOW, COMPLETE WITH MOUNTING
HARDWARE, SEALANT, AND REQUIRED ACCESSORIES, INSTALLED
BENEATH COUNTERTOP FOR A FLUSH AND SEAMLESS FINISH.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 35 ELEVATIONS -
AutoCAD SHX Text
HALF BATH EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/24/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A1.1
4'-3.00"
2'-6.50"
3.50"
1'-9.00"
2'-7.50"
3.50"
ELEVATION OF VANITY ELEVATION OF BATHROOM
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. TOILET TOWEL BARS, AND MIRRORS TO BE PROPERLY PROTECTED IN
PLACE. ANY DAMAGE DONE DURING CONSTRUCTION ILL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR.
4. BATHROOM COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES,
BRAIDED LINES AND TOILETS IN QU42 AND 46 TO BE REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL UNDERMOUNT PORCELAIN LAVATORY SINK(S),
WHITE, WITH INTEGRAL OVERFLOW, COMPLETE WITH MOUNTING
HARDWARE, SEALANT, AND REQUIRED ACCESSORIES, INSTALLED
BENEATH COUNTERTOP FOR A FLUSH AND SEAMLESS FINISH.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 35 ELEVATIONS -
AutoCAD SHX Text
BATHROOM EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/24/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A1.2
3'-5.00"
1'-2.50"
2'-11.50"
3.50"
9'-10.50"
6'-9.00"
2'-11.50"
3.50"
2'-2.50"
9'-10.50"
3'-5.00"
ELEVATION OF WEST KITCHEN WALL ELEVATION OF EAST KITCHEN WALL
UPPER CABINETS TO BE 12" DEEP
UPPER CABINETS TO BE 12" DEEP
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. MICROWAVE, OVEN, AND FRIDGE TO BE PROPERLY REMOVED AND
STORED IN THE GARAGE FOR REINSTALL.
4. KITCHEN COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES, BRAIDED
LINES, GARBAGE DISPOSALS AND RANGE HOODS TO BE REMOVED
AND DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL DOUBLE-BOWL STAINLESS STEEL KITCHEN
SINK(S), UNDERMOUNT TYPE, WITH EQUAL OR OFFSET
COMPARTMENTS, COMPLETE WITH MOUNTING HARDWARE, SEALANT,
AND REQUIRED ACCESSORIES.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 36 ELEVATIONS -
AutoCAD SHX Text
KITCHEN EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/24/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A2
4'-11.00"
ELEVATION OF MASTER BATHROOM
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. TOILET TOWEL BARS, AND MIRRORS TO BE PROPERLY PROTECTED IN
PLACE. ANY DAMAGE DONE DURING CONSTRUCTION ILL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR.
4. BATHROOM COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES,
BRAIDED LINES AND TOILETS IN QU42 AND 46 TO BE REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW SINK CABINET TO BE INSTALLED. TO BE SIMILAR SIZE TO OTHER
HOMES IN THE PROJECT. FINAL CABINET SIZE TO BE APPROVED BY
THE COR.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL UNDERMOUNT PORCELAIN LAVATORY SINK(S),
WHITE, WITH INTEGRAL OVERFLOW, COMPLETE WITH MOUNTING
HARDWARE, SEALANT, AND REQUIRED ACCESSORIES, INSTALLED
BENEATH COUNTERTOP FOR A FLUSH AND SEAMLESS FINISH.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 36 ELEVATIONS -
AutoCAD SHX Text
MASTER BATH EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/24/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A2.1
4'-3.00"
2'-6.50"
3.50"
1'-9.00"
2'-7.50"
3.50"
ELEVATION OF VANITY ELEVATION OF BATHROOM
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. TOILET TOWEL BARS, AND MIRRORS TO BE PROPERLY PROTECTED IN
PLACE. ANY DAMAGE DONE DURING CONSTRUCTION ILL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR.
4. BATHROOM COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES,
BRAIDED LINES AND TOILETS IN QU42 AND 46 TO BE REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL UNDERMOUNT PORCELAIN LAVATORY SINK(S),
WHITE, WITH INTEGRAL OVERFLOW, COMPLETE WITH MOUNTING
HARDWARE, SEALANT, AND REQUIRED ACCESSORIES, INSTALLED
BENEATH COUNTERTOP FOR A FLUSH AND SEAMLESS FINISH.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 36 ELEVATIONS -
AutoCAD SHX Text
BATHROOM EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/24/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A2.2
2' 6"
1'
2' 10.25"
3.50"
10'
2'-11.50"
3.50"
2'-2.50"
9'-10.50"
3'-5.00"
ELEVATION OF EAST KITCHEN WALLELEVATION OF WEST KITCHEN WALL
UPPER CABINETS TO BE 12" DEEP
UPPER CABINETS TO BE 12" DEEP
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. MICROWAVE, OVEN, AND FRIDGE TO BE PROPERLY REMOVED AND
STORED IN THE GARAGE FOR REINSTALL.
4. KITCHEN COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES, BRAIDED
LINES, GARBAGE DISPOSALS AND RANGE HOODS TO BE REMOVED
AND DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL DOUBLE-BOWL STAINLESS STEEL KITCHEN
SINK(S), UNDERMOUNT TYPE, WITH EQUAL OR OFFSET
COMPARTMENTS, COMPLETE WITH MOUNTING HARDWARE, SEALANT,
AND REQUIRED ACCESSORIES.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 42 ELEVATIONS -
AutoCAD SHX Text
KITCHEN EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/25/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A3
4' 1.25"
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. TOILET TOWEL BARS, AND MIRRORS TO BE PROPERLY PROTECTED IN
PLACE. ANY DAMAGE DONE DURING CONSTRUCTION ILL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR.
4. BATHROOM COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES,
BRAIDED LINES AND TOILETS IN QU42 AND 46 TO BE REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW SINK CABINET TO BE INSTALLED. TO BE SIMILAR SIZE TO OTHER
HOMES IN THE PROJECT. FINAL CABINET SIZE TO BE APPROVED BY
THE COR.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL UNDERMOUNT PORCELAIN LAVATORY SINK(S),
WHITE, WITH INTEGRAL OVERFLOW, COMPLETE WITH MOUNTING
HARDWARE, SEALANT, AND REQUIRED ACCESSORIES, INSTALLED
BENEATH COUNTERTOP FOR A FLUSH AND SEAMLESS FINISH.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 42 ELEVATIONS -
AutoCAD SHX Text
MASTER BATH EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/25/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A3.1
4' 2.25"
2' 6.5"
3.50"
2' 6.5"
3.50"
2' 3.75"
ELEVATION OF VANITY ELEVATION OF BATHROOM
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. TOILET TOWEL BARS, AND MIRRORS TO BE PROPERLY PROTECTED IN
PLACE. ANY DAMAGE DONE DURING CONSTRUCTION ILL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR.
4. BATHROOM COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES,
BRAIDED LINES AND TOILETS IN QU42 AND 46 TO BE REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL UNDERMOUNT PORCELAIN LAVATORY SINK(S),
WHITE, WITH INTEGRAL OVERFLOW, COMPLETE WITH MOUNTING
HARDWARE, SEALANT, AND REQUIRED ACCESSORIES, INSTALLED
BENEATH COUNTERTOP FOR A FLUSH AND SEAMLESS FINISH.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 42 ELEVATIONS -
AutoCAD SHX Text
BATHROOM EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/25/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A3.2
2' 8"
1'
2' 9.75"
3.50"
9' 10.50"
2' 9.75"
3.50"
1' 1' 9"
1'
2' 7.50"
9'-10.50"
ELEVATION OF EAST KITCHEN WALLELEVATION OF WEST KITCHEN WALL
UPPER CABINETS TO BE 12" DEEP
UPPER CABINETS TO BE 12" DEEP
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. MICROWAVE, OVEN, AND FRIDGE TO BE PROPERLY REMOVED AND
STORED IN THE GARAGE FOR REINSTALL.
4. KITCHEN COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES, BRAIDED
LINES, GARBAGE DISPOSALS AND RANGE HOODS TO BE REMOVED
AND DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL DOUBLE-BOWL STAINLESS STEEL KITCHEN
SINK(S), UNDERMOUNT TYPE, WITH EQUAL OR OFFSET
COMPARTMENTS, COMPLETE WITH MOUNTING HARDWARE, SEALANT,
AND REQUIRED ACCESSORIES.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 46 ELEVATIONS -
AutoCAD SHX Text
KITCHEN EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/24/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A4
4'-11.00"
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. TOILET TOWEL BARS, SHELVES, AND MIRRORS TO BE PROPERLY
PROTECTED IN PLACE. ANY DAMAGE DONE DURING CONSTRUCTION
ILL BE REPAIRED OR REPLACED AT THE EXPENSE OF THE
CONTRACTOR.
4. BATHROOM COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES,
BRAIDED LINES AND TOILETS IN QU42 AND 46 TO BE REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL UNDERMOUNT PORCELAIN LAVATORY SINK(S),
WHITE, WITH INTEGRAL OVERFLOW, COMPLETE WITH MOUNTING
HARDWARE, SEALANT, AND REQUIRED ACCESSORIES, INSTALLED
BENEATH COUNTERTOP FOR A FLUSH AND SEAMLESS FINISH.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 46 ELEVATIONS -
AutoCAD SHX Text
MASTER BATH EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A4.1
4' 6.25"
2' 7"
3.50"
2' 8"
3.50"
ELEVATION OF VANITY ELEVATION OF BATHROOM
NOTES:
1. ALL MEASUREMENTS TO BE SITE VERIFIED BY CONTRACTOR PRIOR
TO FABRICATION AND INSTALL.
2. WINDOW AND WINDOW FRAMING TO BE PROTECTED IN PLACE. ANY
DAMAGE DONE DURING CONSTRUCTION WILL BE REPAIRED AT THE
EXPENSE OF THE CONTRACTOR.
3. TOILET TOWEL BARS, AND MIRRORS TO BE PROPERLY PROTECTED IN
PLACE. ANY DAMAGE DONE DURING CONSTRUCTION ILL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR.
4. BATHROOM COUNTERTOPS AND CABINETS, SINKS, DRAINPIPES,
BRAIDED LINES AND TOILETS IN QU42 AND 46 TO BE REMOVED AND
DISPOSED OF OFF SITE BY THE CONTRACTOR.
4.1. VISIBLE WALL SURFACE DAMAGE SHALL BE REPAIRED AND
PAINTED TO MATCH EXISTING SURFACES.
5. NEW CABINETS MEASUREMENTS TO MATCH EXISTING LAYOUT.
6. PROVIDE FACTORY-FINISHED KNOTTY ALDER CABINETS WITH A LIGHT
TO MEDIUM STAIN AND CATALYZED CONVERSION VARNISH TOPCOAT,
SATIN SHEEN, APPLIED IN ACCORDANCE WITH AWI/AWMAC
STANDARDS, PRODUCING A UNIFORM APPEARANCE THAT ENHANCES
NATURAL WOOD GRAIN; FINISH SHALL BE DURABLE AND
MOISTURE-RESISTANT.
6.1. CABINET AND DRAWER HARDWARE SUCH AS HANDLES AND
PULL-KNOBS SHALL BE BRUSHED NICKEL FINISH.
6.2. PROVIDE AND INSTALL SOFT-CLOSE HARDWARE ON ALL CABINET
DOORS AND DRAWERS, ENSURING SMOOTH, QUIET OPERATION
AND FULL CLOSURE. CABINET DOORS SHALL INCLUDE
NON-VISIBLE HARDWARE.
7. PROVIDE AND INSTALL MID-GRADE QUARTZ COUNTERTOPS IN A
UNIFORM BEIGE OR WARM NEUTRAL TONE WITH MINIMAL TO NO
VEINING OR PATTERN (FINE SPECKLED APPEARANCE ACCEPTABLE),
INCLUDING A 4-INCH MATCHING BACKSPLASH, CONSISTENT IN COLOR
AND FINISH. TO BE PREAPPROVED BY THE COR.
8. PROVIDE AND INSTALL UNDERMOUNT PORCELAIN LAVATORY SINK(S),
WHITE, WITH INTEGRAL OVERFLOW, COMPLETE WITH MOUNTING
HARDWARE, SEALANT, AND REQUIRED ACCESSORIES, INSTALLED
BENEATH COUNTERTOP FOR A FLUSH AND SEAMLESS FINISH.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
QU 46 ELEVATIONS -
AutoCAD SHX Text
BATHROOM EXISTING
AutoCAD SHX Text
LAYOUT AND NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 01/28/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
A4.2
NOTES:
1. All measurements to be site verified by contractor prior to fabrication and install.
2. Carpet to be installed in all bedrooms for quarters 6, 11, 38, 39, 41, 42, 46, and 51.
3. Carpet and pad will be removed and disposed of. all existing flooring adhesives and fasteners will be removed and disposed of.
3.1. Existing vinyl flooring shall not be removed unless approved by COR.
4. Where complete house baseboard replacement is required, new baseboard shall be mdf, 5”x 9/16”, beveled.
5. Existing flooring subsurface shall be cleaned and prepared according to carpet/lvp manufacturers recommendations. uneven subsurface's will be leveled using leveling mix or methods specified by flooring material manufacturer.
6. All new flooring shall be installed according to manufacturer's specifications and installation guidelines.
Brand: Lyrus Flex Elite Color: Reef 9" x 60" alternative products shall be of equal or greater quality and shall be preapproved by the COR.
Brand: Engineered Floors Style: Pure Color - Step by Step Color: Warm Sand alternative products shall be of equal or greater quality and shall be preapproved by the COR.
NOTES:
1. All measurements to be site verified by contractor prior to fabrication and install.
2. LVP to be installed in all common area and bathrooms for quarters 6, 11, 38, 39, 41, 42, 46, and 51.
3. Carpet and pad will be removed and disposed of. all existing flooring adhesives and fasteners will be removed and disposed of.
3.1. Existing vinyl flooring shall not be removed unless approved by COR.
4. Where complete house baseboard replacement is required, new baseboard shall be mdf, 5”x 9/16”, beveled.
5. Existing flooring subsurface shall be cleaned and prepared according to carpet/lvp manufacturers recommendations. uneven subsurface's will be leveled using leveling mix or methods specified by flooring material manufacturer.
6. All new flooring shall be installed according to manufacturer's specifications and installation guidelines.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
WATCHMAN FLOORING
AutoCAD SHX Text
REPLACEMEMNT DETAILS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/24/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
AutoCAD SHX Text A5
AutoCAD SHX Text A
AutoCAD SHX Text
CARPET DETAILS
AutoCAD SHX Text A5
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text B
AutoCAD SHX Text
LUXURY VINYL PLANK FLOORING (LVP) DETAILS
AutoCAD SHX Text A5
NOT TO SCALE
NOTES:
1. Moen, Sleek, Spot Resistant Stainless steel, One Handle Pull Down.
2. Alternative products shall be of equal or greater quality. Alternative product to be preapproved by COR.
NOTES:
1. Moen, Chateau Chrome One-Handle Low Arc Bathroom Faucet.
2. Alternative products shall be of equal or greater quality. Alternative product to be preapproved by COR.
NOTES:
1. American Standard (Brand), Champion (Model), Two-Piece 1.28 GPF Single Flush Elongated chair Height Toilet with Slow-close Seat in White
2. Alternative products shall be of equal or greater quality. Alternative product to be preapproved by COR.
NOTES:
1. Badger 5, 12 HP Garbage Disposal.
2. Alternative products shall be of equal or greater quality. Alternative product to be preapproved by COR.
NOTES:
1. Broan NU-Tone MTR Series.
2. Alternative products shall be of equal or greater quality. Alternative product to be preapproved by COR.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
TECH. REVIEW:
AutoCAD SHX Text
SUB SHEET NO.
AutoCAD SHX Text
PMIS/PKG NO.
AutoCAD SHX Text
DRAWING NO.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
OF
AutoCAD SHX Text
TITLE OF SHEET
AutoCAD SHX Text
WATCHMAN FIXTURE
AutoCAD SHX Text
REPLACEMEMNT DETAILS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ZION
AutoCAD SHX Text
MM
AutoCAD SHX Text
ZION
AutoCAD SHX Text 03/31/2026
AutoCAD SHX Text
WATCHMAN HOUSING
AutoCAD SHX Text
ZION NATIONAL PARK
AutoCAD SHX Text 327856
AutoCAD SHX Text A5.1
AutoCAD SHX Text A
AutoCAD SHX Text
KITCHEN FAUCET
AutoCAD SHX Text A5.1
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text B
AutoCAD SHX Text
BATHROOM FACUET
AutoCAD SHX Text A5.1
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text C
AutoCAD SHX Text
TOILET (QU 42 AND 46)
AutoCAD SHX Text A5.1
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text D
AutoCAD SHX Text
GARBAGE DISPOSAL
AutoCAD SHX Text A5.1
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text E
AutoCAD SHX Text
KITCHEN RANGE HOOD
AutoCAD SHX Text A5.1
NOT TO SCALE
File details come from the government source that posted it. Updated .