ATTACHMENT 2 - DRAWINGS.pdf

PDF 302 KB Posted

Attached to
Lower Monumental Lock & Dam Powerhouse Entry Doors Federal contract opportunity
Solicitation number
W912EF25QA037
Issued by
Department of the Army Corps of Engineers Engineering District Walla Walla

About this file

This document is an architectural drawing from the US Army Corps of Engineers showing detailed design specifications for automatic sliding doors at two different elevations (EL 460 and EL 553). The drawings include multiple views including plan views, interior elevations, sections, and floor layouts, with specific technical details such as door dimensions (5'-4" and 6'-0"), incorporation of existing badge reader functionality, and a panic bar feature to disconnect the door opener during power failure events. The drawing set is dated 4 JUN 2025, with a solicitation and contract number format of W91328-XX-X-XXXX, and includes two general notes indicating the document is for information purposes and referencing additional specification details for door requirements.

View the file

Other files for this federal contract opportunity

Other files attached to Lower Monumental Lock & Dam Powerhouse Entry Doors, newest first.
File Type Posted
ATTACHMENT 1 - TECHNICAL SPECIFICATIONS_AMENDMENT 0002.pdf PDF
Solicitation Amendment W912EF25QA0370002 SF 30.pdf PDF
Solicitation Amendment W912EF25QA0370001 SF 30.pdf PDF
ATTACHMENT 1 - TECHNICAL SPECIFICATIONS_AMENDMENT 0001.pdf PDF
ATTACHMENT 3 - DOOR PICTURES.pdf PDF
ATTACHMENT 1 - TECHNICAL SPECIFICATIONS.pdf PDF
Solicitation - W912EF25QA037.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NEW AUTOMATIC

SLIDING DOOR

A9 X-101

DOOR TO INCORPORATE

EXISTING BADGE READER

FUNCTIONALITY

CONCRETE OPENING

3' - 4 1/2"

4'

0"

PANIC BAR OR OTHER EQUAL FEATURE TO

DISCONNECT OPENER IN POWER FAILURE EVENT

4 - MAIN FLOOR &

WAREHOUSE

460' - 0"

A9 X-101

SINGLE LIGHT,

24"x24" +/-

NEW SLIDER DOOR

W/ MOTION SENSOR, WIRED TO

EXISTING BADGE READER

(QTY 1 NEEDED)

NOT TO EXCEED

8' - 4 1/2"

SLAB WIDTH

3' - 5 1/2" +/-

6'

SL

AB

H

T

MOTION SENSOR

PANIC BAR OR OTHER EQUAL

FEATURE TO DISCONNECT OPENER

IN POWER FAILURE EVENT

4' - 0"

4 - MAIN FLOOR &

WAREHOUSE

460' - 0"

C O

N C

R

ET

E O

PE

N

IN

G

7'

1/

2"

CONC. OPENING

5' - 4"

8"

X-101A15

DOOR TO INCORPORATE

EXISTING BADGE READER

FUNCTIONALITY

6' - 0"

NEW AUTOMATIC

SLIDING DOOR

PANIC BAR OR OTHER EQUAL

FEATURE TO DISCONNECT

OPENER IN POWER FAILURE

EVENT

9 - TOP OF DAM

553' - 0"

15"x15"+/- LIGHT

PANIC BAR

(SWING OUT)

(IF DOOR DESIGN

ALLOWS)

EXTERIOR ROOF HT

560' - 2"

C O

N C

R

ET

E O

PE

N

IN

G

7'

2"

7'

2"

SL

AB

H

T

(OPEN POSITION)

MOTION SENSOR

X-101 G1

X-101 F15

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

FI

LE

N O

C :\U se rs

\g 4e cd bj e\ O ne D riv e

- U S

Ar m y C or ps o f E ng in ee rs

LO

M O

F

IL

ES

\C

LO

C

AL

R

EV

IT

W

O R

K

\3 .P

PO

W

ER

H O

U

SE

\3 .P

ER

EC

TI

O N

B

AY

M

AS

TE

R .rv t 6/

/2

7:

:5

AM

X-101

W

AL

LA

W

AL

LA

D

IS

TR

IC

T

N

R

D A

VE

W

AL

LA

W

AL

LA

, W

A

B.

E

D D

Y

B.

E

D D

Y

J.

M

AL

Y

JU

N

W

8-

XX

-X

-X

XX

X

W

8-

XX

-X

-X

XX

X

FO

R

IN

FO

R M

AT

IO

N O

N

LY

EN

TR

Y D

O O

R S

- E L

EL

LO

W

ER

M

O N

U M

EN

TA

L

LO

C K

D

AM

R

EP

LA

C

EM

EN

T

EN

TR

Y

D O

O R

S

SN

AK

E R

IV

ER

, O R

EG

O

N , W

AS

H

IN

G

TO

N

, A N

D

ID

AH

O

PO

W

ER

H

O U

SE

ER

EC

TI

O

N B

AY

GENERAL NOTES

1. FOR INFORMATION ONLY

2. REFER TO SPECIFICATIONS FOR DOOR REQUIREMENT DETAILS

1/4" = 1'-0"G1 EL 460 DOOR - PLAN VIEW

1/4" = 1'-0"A1 EL 460 DOOR - INTERIOR ELEV.

1/4" = 1'-0"A9 EL 460 DOOR - SECTION

1/4" = 1'-0"F15 EL 553 DOOR - PLAN VIEW

1/4" = 1'-0"A15 EL 553 DOOR - INTERIOR ELEV.

1" = 20'-0"G9 4 - EL 460 - MAIN FLOOR & WAREHOUSE

1/8" = 1'-0"K15 EL 553 FL9 - TOP OF DAM

File details come from the government source that posted it. Updated .