Attachment 2 - Drawings - 589A5-21-702 EHRM Training and Admin Topeka Drawings.pdf
PDF 21 MB Posted
- Solicitation number
- 36C77622B0058
About this file
This file attachment is related to a federal contract solicitation for construction renovation services. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking offers to renovate the EHRM Training Room located in Topeka, Kansas. Offerors should reference solicitation number 36C77622B0058 in their responses. The solicitation involves renovating the specified training room space at the Topeka VA Medical Center campus to upgrade facilities and improve the learning environment for employee health risk management training programs. Responses are due by the date specified on FedBizOpps for this opportunity. The awarded contractor will be expected to complete the construction and renovation work according to required specifications, designs, and standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C77622B0058 0001.docx | DOCX document | |
| S05 - Vendor Questions and Answers.pdf | ||
| Attachment 1 - Specs - 589A5-21-702 EHRM Training and Admin Topeka (1).pdf | ||
| Attachment 6 - DBA Wage Rate - Shawnee County - 10-7-22.pdf | ||
| Attachment 3 - Site Visit Memo.docx | DOCX document | |
| Attachment 4 - Contractor Safety - Environmental Form.docx | DOCX document | |
| Attachment 7 - Limitations on Subcontracting - Construction.docx | DOCX document | |
| Attachment 5 - COVID-19 Safety Protocols 12-14-21.pdf | ||
| 36C77622B0058.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B L
E A
C H
E R
S
UP
UP
UP
UP
UP
DN
UP UP
UPUP
UP
SW GAGE BLVD
S W
1S
T S
T R
E E
T
BUILDING 1
BUILDING 21
B U
IL
D
IN
G
BLDG 1, ROOM A145
BLDG 1, ROOM C106
BLDG 1, ROOM C114
BLDG 5, ROOM B214
BLDG 5, ROOM B207
BLDG 21, ROOM 106
BLDG 21, ROOM 103
th re e in c h e s o n e fo o t 6 o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENG.
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
1424 GLEN COVE DRIVE
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
COMMISSIONING
ES2
13401 N SANTA FE AVE.
OKLAHOMA CITY, OK 73114
(405) 528-4500
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:2 :3
P
M
COVER SHEET
NR
01 62
BGJ
BID DOCUMENTS
EHRM TRAINING AND ADMINISTRATION
SPACE SUPPORT DESIGN
VA PROJECT NUMBER: 589A5-21-702
EHRM TRAINING AND
ADMINISTRATION SPACE
SUPPORT DESIGN
1/27/2022
589A5-21-702
COLMERY-O'NEIL VA MC
2200 SW GAGE BLVD
TOPEKA, KS 66622
COLMERY-O'NEIL VA MEDICAL CENTER
2200 SW GAGE BLVD
TOPEKA, KS 66622
BID DOCUMENTS
GI000
1, 5, 21
SPUR #: 1794.14
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[00] GENERAL
01 GI000 COVER SHEET
02 GI001 GENERAL INFORMATION
[02] ENVIRONMENTAL
03 HA100 BUILDING 1 - FIRST FLOOR - ENVIRONMENTAL HAZARDS
04 HA500 BUILDING 5 - SECOND FLOOR - ENVIRONMENTAL HAZARDS
05 HA210 BUILDING 21 - FIRST FLOOR - ENVIRONMENTAL HAZARDS
[03] STRUCTURAL
06 S-001 STRUCTURAL GENERAL NOTES
[04] ARCHITECTURAL
07 AE101 REFERENCE PLAN - BLDG 1
08 AE102 REFERENCE PLAN - BLDG 5
09 AE103 REFERENCE PLAN - BLDG 21
10 AE401 ENLARGED PLANS - BLDG 1 - RM A145
11 AE402 ENLARGED PLANS - BLDG 1 - RM C106
12 AE403 ENLARGED PLANS - BLDG 1 - RM C114
13 AE404 ENLARGED PLANS - BLDG 1 - RM C114
14 AE405 ENLARGED PLANS - BLDG 5 - RM 214A
15 AE406 ENLARGED PLANS - BLDG 5 - RM 207
16 AE407 ENLARGED PLANS - BLDG 21 - RM 106
17 AE408 ENLARGED PLANS - BLDG 21 - RM 103
18 AF700 INTERIOR ELEVATIONS
19 AF701 INTERIOR ELEVATIONS
20 AF702 DETAILS AND SCHEDULES
21 AF703 SECTION DETAILS
[05] FIRE PROTECTION
22 FA001 FIRE ALARM NOTES MATRIX AND RISER DIAGRAM
23 FA101 FIRE ALARM AUDIBILITY AND INTELLIGIBILITY - BLDG 1 - C114
24 FA102 FIRE ALARM AUDIBILITY AND INTELLIGIBILITY - BLDG 5 - B207
25 FA103 FIRE ALARM AUDIBILITY AND INTELLIGIBILITY - BLDG 21 - B214
26 FA401 FIRE ALARM ENLARGED PLANS - BLDG 1
27 FA402 FIRE ALARM ENLARGED PLANS - BLDG 1
28 FA403 FIRE ALARM ENLARGED PLANS - BLDG 5
29 FA404 FIRE ALARM ENLARGED PLANS - BLDG 21
30 FA500 FIRE ALARM DETAILS
31 FX001 FIRE SPRINKLER NOTES
32 FX101 FIRE SUPRESSION HAZARD CLASSIFICATION - BLDG 1 - C114
33 FX102 FIRE SUPRESSION HAZARD CLASSIFICATION - BLDG 5 - B207
34 FX103 FIRE SUPRESSION HAZARD CLASSIFICATION - BLDG 21 - B214
35 FX500 FIRE SPRINKLER DETAILS
[06] MECHANICAL
36 M-000 MECHANICAL LEGEND, ABBREVIATIONS, AND GENERAL NOTES
37 M-101 REFERENCE PLAN - BLDG 1
38 M-401 ENLARGED PLANS - BLDG 1
39 M-501 MECHANICAL DETAILS AND SCHEDULES
[07] ELECTRICAL
40 E-000 ELECTRICAL LEGEND AND ABBREVIATIONS
41 E-101 ELECTRICAL REFERENCE PLAN - BLDG 1 - LEVEL 1
42 E-102 ELECTRICAL REFERENCE PLAN - BLDG 5 - LEVEL 5
43 E-103 ELECTRICAL REFERENCE PLAN - BLDG 21 - LEVEL 1
44 E-401 ENLARGED PLANS - BUILDING 1
45 E-402 ENLARGED PLANS - BUILDING 1
46 E-403 ENLARGED PLANS - BUILDING 1
47 E-404 ENLARGED PLANS - BUILDING 5
48 E-405 ENLARGED PLANS - BUILDING 5
49 E-406 ENLARGED PLANS - BUILDING 21
50 E-407 ENLARGED PLANS - BUILDING 21
51 E-601 ELECTRICAL ONE-LINE DRAWING - BUILDING 1, 5 AND 21
52 E-602 ELECTRICAL SCHEDULES AND DETAILS
53 E-603 ELECTRICAL PANELBOARD SCHEDULES
[08] TECHNOLOGY
54 T-000 TECHNOLOGY LEGEND AND ABBREVIATIONS
55 T-101 TECHNOLOGY REFERENCE PLAN - BLDG 1 - LEVEL 1
56 T-102 TECHNOLOGY REFERENCE PLAN - BLDG 5 - LEVEL 5
57 T-103 TECHNOLOGY REFERENCE PLAN - BUILDING 21 - LEVEL 1
58 T-401 ENLARGED PLANS - BLDG 1
59 T-402 ENLARGED PLANS - BLDG 1
60 T-403 ENLARGED PLANS - BLDG 5
61 T-404 ENLARGED PLANS - BLDG 21
62 T-501 TECHNOLOGY DETAILS
TOTAL SHEETS: 62
DEDUCT ALTERNATES
DEDUCT OPTION 1:
EXCLUDING RENOVATION SCOPE FOR ROOM 106 IN BUILDING 21
DEDUCT OPTION 2:
EXCLUDING RENOVATION SCOPE FOR ROOM 145 IN BUILDING 1
1" = 200'-0"
COLMERY-O'NEIL VA MEDICAL CENTER CAMPUS MAP
BUILDING 1 - KEY PLAN
BUILDING 5 - KEY PLAN
BUILDING 21 - KEY PLAN
N
N
N
N
No. REVISION DESCRIPTION DATE
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -3
M
IN
1'-6" MIN1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
VA TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
"M A
X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
" 4' -0
M
IN
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
'-0
WALL
WALL
4' -0
M
A X
WALL HOOK
7' -0
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
4' -0
"M A
X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
2'-6"
4' -0
2'-6"
4' -0
HANDRAILS AND
BUMPERGUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS
SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2021 VA INFRASTRUCTURE STANDARD FOR TELECOMMUNICATION SPACES
• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2021 NATIONAL FIRE CODES (NFPA)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2021 INTERNATIONAL MECHANICAL CODE
• 2020 NATIONAL ELECTRICAL CODE (NEC), NFPA 70
• 2021 INTERNATIONAL PLUMBING CODE (IPC)
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT
NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.
DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES
EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ASHRAE 90.1 - 2019 EDITION
BUILDING LOCATION: TOPEKA, KS
CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 4A
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM
AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.
BUILDING ENVELOPE REQUIREMENTS (5.5 )
BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)
ROOFS REQUIRED DESIGNED
INSULATION: R-30 c.i. EXISTING METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls EXISTING
ATTIC AND OTHER: R-49 EXISTING
WALLS, ABOVE GRADE
MASS: R-9.5 c.i. EXISTING METAL BUILDING: R-0 + R-15.8 c.i. EXISTING STEEL-FRAMED: R-13 + R-7.5 c.i. EXISTING WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 EXISTING
WALL, BELOW GRADE
BELOW-GRADE WALL: R-7.5 c.i. EXISTING
FLOORS
MASS: R-14.6 c.i. EXISTING
STEEL-FRAMED: R-30 EXISTING
WOOD-FRAMED AND OTHER: R-30 EXISTING
SLAB-ON-GRADE FLOORS
UNHEATED SLABS: R-15 for 24 in. EXISTING HEATED SLABS: R-20 for 24 in. EXISTING
OPAQUE DOORS
SWINGING: U-0.370 EXISTING
NONSWINGING: U-0.310 EXISTING
FENESTRATION (TABLE 5.5-4):
VERTICAL FENESTRATION, U-FACTOR
FIXED: U-0.36 EXISTING
OPERABLE: U-0.45 EXISTING
ENTRANCE DOOR: U-0.63 EXISTING
DEFINITIONS
c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM
NR = NO (INSULATION) REQUIREMENT
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL
CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE
ENTIRE DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY
WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY
ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE
CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK
AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN
PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED
OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE
OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT
PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE
ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER
DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A
WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE
AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND
ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,
BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL
DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE
OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION
DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND
OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND
SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL
SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE
DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO
THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH
SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,
EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR
INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60
CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS
DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER
MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE
THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS
REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,
IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME
SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF
THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY
OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE
INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN
ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY
AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING
THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR
DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING
BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE
DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION
DOCUMENTS.
13. REFER TO THE DESIGN BINDER FOR THE ICRA INFORMATION DOCUMENTATION.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
ROOM NAME
000A
150 SF
/1 A101
X0000
6"
3' -0
M
A X
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINIUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALK BOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CPT CAROET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPXOY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 6"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4"
6"
3"
6" 1'
-6
6" MAX
7" - 9" 11" MIN
17" - 25"
M
IN
6' -0
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -6
M
A X
5' -0
M
A X
R
RAF RESILIENT ATHETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SPECIALTY COATING
SD STATIC DISSIPATIVE FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSTICLAL TILE
VP VENEERED PLASTER
VT VINYL TILE
VV VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
th re e in c h e s o n e fo o t 6 o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENG.
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
1424 GLEN COVE DRIVE
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
COMMISSIONING
ES2
13401 N SANTA FE AVE.
OKLAHOMA CITY, OK 73114
(405) 528-4500
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
/2
/2
:2 :3
P
M
GENERAL INFORMATION
NR
02 62
BGJ
BID DOCUMENTS
EHRM TRAINING AND
ADMINISTRATION SPACE
SUPPORT DESIGN
1/27/2022
589A5-21-702
COLMERY-O'NEIL VA MC
2200 SW GAGE BLVD
TOPEKA, KS 66622
GI001
1, 5, 21
SPUR #: 1794.14
t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENG.
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
1424 GLEN COVE DRIVE
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
COMMISSIONING
ES2
13401 N SANTA FE AVE.
OKLAHOMA CITY, OK 73114
(405) 528-4500
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
STAMP:
Drawing Number
Building Number
P
M
BUILDING 1 - FIRST FLOOR - ENVIRONMENTAL
HAZARDS
CD
03 62
JR
EHRM TRAINING AND
ADMINISTRATION SPACE
SUPPORT DESIGN
01/27/2022
589A5-21-702
COLMERY-O'NEIL VA MC
2200 SW GAGE BLVD
TOPEKA, KS 66622
HA100
1, 5, 21
SPUR #: 1794.14
No. REVISION DESCRIPTION DATE
KEY NOTES
REMOVE RESILIENT COVE BASE COVER MOLDING AND ADHESIVE FROM
THE UNDERLYING 6" ASBESTOS TERRAZZO BASE USING MANUAL MEANS
AND LOW VOC CHEMICAL METHODS WITHIN A REGULATED AREA, 60 LF
COVE BASE.
REMOVE NON-ASBESTOS CARPET AND ADHESIVE FROM UNDERLYING 6"
ASBESTOS TERRAZZO BASE USING MANUAL MEANS AND LOW VOC
CHEMICAL METHODS IN A REGULATED AREA, 75 LF OF COVE BASE.
HIDDEN ASBESTOS WINDOW CAULK AND/OR GLAZE, PROTECT AS
NECESSARY.
ASBESTOS TRANSITE AND/OR BLACK TAR (PACM) PRESENT IN HEAT
CONVECTOR WALL POCKET, PROTECT AS NECESSARY.
ASBESTOS PIPE INSULATION AND MUDDED FITTINGS PRESENT IN
PLASTER CHASE, PROTECT AS NECESSARY.
ASSUMED ASBESTOS BLACK TAR AT EXTERIOR WALL FACE AND VOID,
PROTECT AS NECESSARY.
ASSUMED HIDDEN WINDOW ASSEMBLY WITH ASBESTOS AND LEAD
COMPONENTS, PROTECT AS NECESSARY.
ASBESTOS TERRAZZO COVEBASE PRESENT BEHIND INTERIOR FINISH
WALLS, PROTECT AS NECESSARY.
ASBESTOS BUILT-UP ROOF SYSTEM (PACM), PROTECT AS NECESSARY.
ASBESTOS TERRAZZO COVEBASE MAY BE PRESENT BEHIND INTERIOR
FINISH WALLS, PROTECT AS NECESSARY.
DO NOT PROCEED WITH DUCT DEMOLITION OR REMOVAL OF DUCT
INSULATION UNTIL WHICH TIME AN ASBESTOS SURVEY WITH LISTED
SUSPECT ASBESTOS SAMPLE RESULTS HAVE BEEN PROVIDED TO THE
VACOR. PROCEED IN ACCORDANCE WITH ANY ASBESTOS RELATED
INSTRUCTIONS. IN CONCORDANCE WITH REMOVAL OF DRYWALL
CEILING, CONDUCT SURVEY ABOVE CEILING WITH MATERIAL EMPHASIS
OF ASBESTOS DUCT INSULATION, ASBESTOS DUCT SEAM SEALANTS,
AND CAULKS. CONTRACTOR INSPECTION SURVEY TO BE PERFORMED
BY A VACOR APPROVED LICENSED ASBESTOS INSPECTOR. WHERE
ASBESTOS MATERIALS ARE PRESENT AND WILL BE IMPACTED BY WORK,
PERFORM ALL DUCT DEMOLITION/REMEDIATION AT ADDITIONAL COST BY
LICENSED PERSONNEL WITHIN A NEGATIVE PRESSURE ENCLOSURE IN
ACCORDANCE WITH SPECIFICATION 02 82 11, TRADITIONAL ASBESTOS
ABATEMENT, 1 INSPECTION SURVEY.
WHERE 9" X 9" FLOOR TILE AND/OR UNDERLYING BLACK MASTIC IS
ENCOUNTERED UNDER CARPET, STOP WORK AND REPORT DISCOVERY
TO VACOR, PROTECT AS NECESSARY. AN APPROVED LICENSED
ASBESTOS INSPECTOR IS REQUIRED TO VISUALLY OBSERVE NUMEROUS
LOCATIONS UNDER CARPET IN CENTER AREAS TO ACCESS POTENIAL.
WHERE 9" X 9" FLOOR TILE IS OBSERVED, REMOVE AT ADDITIONAL COST
BY LICENSED PERSONNEL WITHIN A NEGATIVE PRESSURE ENCLOSURE
IN ACCORDANCE WITH SPECIFICATION 02 82 13 19, ASBESTOS FLOOR
TILE AND MASTIC ABATEMENT.
REMOVE DOOR FRAME WITH LBP USING MANUAL MEANS WITHIN A
NEGATIVE PRESSURE ENCLOSURE, 1 DOOR FRAME AND 1 NEGATIVE
PRESSURE ENCLOSURE.
LBP ORANGE LBP STEAM OR DRAIN PIPE, PROTECT AS NECESSARY.
LBP ORANGE PIPE HANGERS AND/OR SADDLES, PROTECT AS
NECESSARY.
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
UP
UP
DN
UP
DF
DF
A7 A7
L3
L3
A7
A7
A7
A7
A5 A4
A3
A6 A4
A3
A1
L2
A4
A3
A4
A3A3 A3
A6
L2
L2
L3
A2
L3
L3
L1
A9
L3
A8
A2
A8
A10
GENERAL NOTES
CONTRACTOR IS TO BE LICENSED TO ENGAGE IN ASBESTOS AND LEAD RELATED PROJECT WORK AND USE LICENSED/TRAINED PERSONNEL.
ABATEMENT WORK WILL REQUIRE THREE MOBILIZATIONS TO FACILITATE WORK FLOW IN ACCORDANCE WITH AN APPROVED PROJECT SCHEDULE.
WITHIN AN NPE, HVAC AIR FLOW SHALL BE SHUTDOWN AND DUCT OPENINGS COVERED WITH CRITICAL BARRIERS THROUGHOUT ABATEMENT. SCHEDULE SHUTDOWNS WITH THE VACOR TO ACCOMMODATE
FACILITY AND CONSTRUCTION REQUIREMENTS.
ALL AUTHORIZED PERSONNEL WITHIN AN NPE SHALL DON, AT MINIMUM, HALF FACE AIR PURIFYING RESPIRATORS WITH P100 FILTERS, DISPOSABLE DUST SUITS (WITH BOOT AND HEAD COVERS) AND GLOVES.
RESPIRATORY PROTECTION MAY REQUIRE USE OF POWERED AIR PURIFYING RESPIRATORS.
REGULATED AREA NEGATIVE PRESSURE ENCLOSURES SHALL BE PREPARED IN ACCORDANCE WITH THE FOLLOWING:A) ALL FLOORS, CEILINGS AND WALLS SHALL BE ISOLATED USING 2-LAYERS OF 6-MIL POLY
SHEETING; B) OSHA ASBESTOS SIGNAGE AT ENTRANCE TO REGULATED AREAS; C)SINGLE-POINT OF ENTRY WITH 3-STAGE WET DECONTAMINATION STATION TO ALLOW WORKERS TO REMOVE PPE, WASH AND
VACUUM THEMSELVES OFF PRIOR TO EXITING THE REGULATED WORK AREA; D) MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN WG OR BETTER) USING HEPA FILTERED AIR MACHINES WITH EXHAUST ROUTED TO
OUTDOORS; E) MINIMUM OF 4 AIR CHANGES PER HOUR; F) CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS TO CHANGE INTO STREET CLOTHES (OPAQUE POLY REQUIRED AS NEEDED FOR PRIVACY); G)
RENEWABLE ADHESIVE MATS IMMEDIATELY OUTSIDE OF REGULATED WORK AREA TO ENSURE FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO OTHER AREAS OF FACILITY.
PERFORM ABATEMENT USING THE FOLLOWING CONTROLS: A) HEPA FILTERED VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B) ONLY MANUAL REMOVAL MEANS/TOOLS ARE ALLOWED TO DISTURB ACM
(MECHANICAL TOOLS PROHIBITED FOR ACM REMOVAL).
CLEANING OF REGULATED WORK AREAS IS TO INCLUDE HEPA VACUUMING & WET WIPING METHODS. REGULATED AREAS ARE TO PASS A SUCCESSFUL VISUAL INSPECTION BY THE VPIH PRIOR TO COLLECTION OF
CLEARANCE SAMPLES.
VPIH WILL PERFORM PERIMETER AIR MONITORING, VISUAL INSPECTIONS AND FINAL AIR CLEARANCE SAMPLING.
CONTRACTOR TO PERFORM OSHA EMPLOYEE EXPOSURE MONITORING.
WASTE PRODUCED DURING REMEDIATION SHALL BE COLLECTED, CONTAINERIZED, LABELED, CHARACTERIZED AND DISPOSED IN ACCORDANCE WITH ASBESTOS AND LEAD SPECIFICATIONS 02.82.11 AND 02833313.
WASTE CONTAINERS, TOOLS, EQUIPMENT, ETC. SHALL BE WET WIPED PRIOR TO LEAVING REGULATED WORK AREA.
WHERE THE COMBINED AREA OF THE NPE INCLUDING , DECONTAMINATION, LOADOUT, AND WORK CHAMBERS DOES NOT FIT WITHIN A ROOM, THE DECON/LOADOUT CONFIGURATION MAY EXTEND INTO 1/2 WIDTH
OF THE HALLWAY AS REQUIRED TO ALLOW PASSAGE IN CORRIDOR
A11
A11
A12
A11
BID DOCUMENTS
A12
L1
L2
L3
VISUAL KEY
AREA OF ASBESTOS TERRAZZO COVE BASE
NEGATIVE PRESSURE ENCLOSURE
2,000 CFM HEPA FILTERED AIR MACHINE
3-STAGE WET DECON CHAMBER
DEC
AIR
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text A141
AutoCAD SHX Text C110
AutoCAD SHX Text C109
AutoCAD SHX Text C107
AutoCAD SHX Text C108
AutoCAD SHX Text C116F
AutoCAD SHX Text C116A
AutoCAD SHX Text C116
AutoCAD SHX Text C116B
AutoCAD SHX Text C105
AutoCAD SHX Text C104
AutoCAD SHX Text C106
AutoCAD SHX Text C115
AutoCAD SHX Text A142
AutoCAD SHX Text A143F
AutoCAD SHX Text C116C
AutoCAD SHX Text C116D
AutoCAD SHX Text C119
AutoCAD SHX Text C120
AutoCAD SHX Text C124
AutoCAD SHX Text C125
AutoCAD SHX Text C121
AutoCAD SHX Text C122
AutoCAD SHX Text C123
AutoCAD SHX Text C123B
AutoCAD SHX Text C123A
AutoCAD SHX Text C126
AutoCAD SHX Text C127
AutoCAD SHX Text C1-02
AutoCAD SHX Text A145
AutoCAD SHX Text C117
AutoCAD SHX Text C104F
AutoCAD SHX Text C116E
AutoCAD SHX Text C105E
AutoCAD SHX Text A143
AutoCAD SHX Text C102
AutoCAD SHX Text C101
AutoCAD SHX Text A144
AutoCAD SHX Text C103
AutoCAD SHX Text C113
AutoCAD SHX Text C112
AutoCAD SHX Text C111
AutoCAD SHX Text C114D
AutoCAD SHX Text C114
AutoCAD SHX Text C114B
AutoCAD SHX Text C114C
AutoCAD SHX Text C114C
AutoCAD SHX Text C114
AutoCAD SHX Text C1-03
AutoCAD SHX Text C1-01
AutoCAD SHX Text A142A
AutoCAD SHX Text A101G
AutoCAD SHX Text C114T
AutoCAD SHX Text A1-E4
AutoCAD SHX Text A101H
AutoCAD SHX Text A101J r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENG.
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
1424 GLEN COVE DRIVE
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
COMMISSIONING
ES2
13401 N SANTA FE AVE.
OKLAHOMA CITY, OK 73114
(405) 528-4500
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
STAMP:
Drawing Number
Building Number
P
M
BUILDING 5 - SECOND FLOOR -
ENVIRONMENTAL HAZARDS
CD
04 62
JR
EHRM TRAINING AND
ADMINISTRATION SPACE
SUPPORT DESIGN
01/27/2022
589A5-21-702
COLMERY-O'NEIL VA MC
2200 SW GAGE BLVD
TOPEKA, KS 66622
HA500
1, 5, 21
SPUR #: 1794.14
No. REVISION DESCRIPTION DATE
KEY NOTES
REMOVE NON-ASBESTOS FLOOR TILE WITH UNDERLYING FLOOR LEVELER AND ASBESTOS
BLACK MASTIC USING MANUAL MEANS WITHIN NEGATIVE PRESSURE ENCLOSURE, 1,400 SF.
REMOVE NON-ASBESTOS FLOOR TILE WITH UNDERLYING ASBESTOS BLACK MASTIC REMNANT
USING MANUAL MEANS WITHIN NEGATIVE PRESSURE ENCLOSURE, 725 SF.
REMOVE RESILIENT COVE BASE MOLDING AND REMOVE MASTIC FROM THE 6" ASBESTOS
UNDERLYING TERRAZZO BASE USING MANUAL MEANS AND CHEMICAL METHODS WITHIN A
NEGATIVE PRESSURE ENCLOSURE, 145 LF RM B207 AND 110 LF IN ROOM B214A.
HIDDEN ASBESTOS WINDOW CAULK AND/OR GLAZE, PROTECT AS NECESSARY.
ASBESTOS TRANSITE AND/OR BLACK TAR (PACM) PRESENT IN HEAT CONVECTOR WALL POCKET,
PROTECT AS NECESSARY.
POTENTIAL FOR ASBESTOS PIPE INSULATION AND MUDDED FITTINGS, PROTECT AS NECESSARY.
ASSUMED ASBESTOS BLACK TAR AT EXTERIOR WALL FACE AND VOID, PROTECT AS NECESSARY.
ASBESTOS BUILT-UP ROOF SYSTEM (PACM), PROTECT AS NECESSARY.
LBP WINDOW COMPONENTS, PROTECT AS NECESSARY.
A1
A2
A3
A4
A5
A6
A7
A8
L1
VISUAL KEY
ABATEMENT AREA OF FLOOR TILE WITH UNDERLYING FLOOR LEVEL AND ASBESTOS BLACK
MASTIC
ABATEMENT AREA OF FLOOR TILE WITH UNDERLYING ASBESTOS BLACK MASTIC REMNANT
AREA OF ASBESTOS TERRAZZO COVE BASE
NEGATIVE PRESSURE ENCLOSURE
3-STAGE WET DECON CHAMBER
2,000 CFM HEPA FILTERED AIR MACHINE
DEC
AIR
B223A
B223B C236A C236B
B223
B223C
C236 C236C
B222
B224
B221
B225
B215
B214C
B226
B215E
B214A B211E
A202E
B211 B210
B214 B213
B212
B209
B207A
B208
B206
A201E
B205
B204 B203
A202
A201
A257
C256 C255
C253A
C253
C251 C252A
C254
C250
C249
C248
C247
C245C
C246
C245D
B217/B218
B219
B2-C1
A2-C1
A227
B220F
DN
B220
B226A B226B
DN
UP
A229
A228F
A228
C240
C2-C1
C247E
A230
EL-1
A231 A232
C223A
C233
C233B
C242
C241
C244E
C234
C238
C238F
DN
C239
C244
C245
C245B
C235 C237
B207
C252
B B
B
B P
C
P
C
C A
L1
A5
A4
L1
A5
A4
L1
A4
A3
A2
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A4
A8
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
L1
A5
A4
A4L1
A4L1
A4
L1
A4
L1
A3
A8
A7
A7
A6
A7
A7
A6
BID DOCUMENTS
GENERAL NOTES
CONTRACTOR IS TO BE LICENSED TO ENGAGE IN ASBESTOS AND LEAD RELATED PROJECT WORK AND USE LICENSED/TRAINED PERSONNEL.
ABATEMENT WORK WILL REQUIRE THREE MOBILIZATIONS TO FACILITATE WORK FLOW IN ACCORDANCE WITH AN APPROVED PROJECT SCHEDULE.
WITHIN AN NPE, HVAC AIR FLOW SHALL BE SHUTDOWN AND DUCT OPENINGS COVERED WITH CRITICAL BARRIERS THROUGHOUT ABATEMENT. SCHEDULE SHUTDOWNS WITH THE VACOR TO ACCOMMODATE FACILITY AND CONSTRUCTION REQUIREMENTS.
ALL AUTHORIZED PERSONNEL WITHIN AN NPE SHALL DON, AT MINIMUM, HALF FACE AIR PURIFYING RESPIRATORS WITH P100 FILTERS, DISPOSABLE DUST SUITS (WITH BOOT AND HEAD COVERS) AND GLOVES. RESPIRATORY PROTECTION MAY REQUIRE USE OF POWERED AIR PURIFYING
RESPIRATORS.
REGULATED AREA NEGATIVE PRESSURE ENCLOSURES SHALL BE PREPARED IN ACCORDANCE WITH THE FOLLOWING:A) ALL FLOORS, CEILINGS AND WALLS SHALL BE ISOLATED USING 2-LAYERS OF 6-MIL POLY SHEETING; B) OSHA ASBESTOS SIGNAGE AT ENTRANCE TO REGULATED
AREAS; C)SINGLE-POINT OF ENTRY WITH 3-STAGE WET DECONTAMINATION STATION TO ALLOW WORKERS TO REMOVE PPE, WASH AND VACUUM THEMSELVES OFF PRIOR TO EXITING THE REGULATED WORK AREA; D) MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN WG OR BETTER)
USING HEPA FILTERED AIR MACHINES WITH EXHAUST ROUTED TO OUTDOORS; E) MINIMUM OF 4 AIR CHANGES PER HOUR; F) CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS TO CHANGE INTO STREET CLOTHES (OPAQUE POLY REQUIRED AS NEEDED FOR PRIVACY); G) RENEWABLE
ADHESIVE MATS IMMEDIATELY OUTSIDE OF REGULATED WORK AREA TO ENSURE FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO OTHER AREAS OF FACILITY.
PERFORM ABATEMENT USING THE FOLLOWING CONTROLS: A) HEPA FILTERED VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B) ONLY MANUAL REMOVAL MEANS/TOOLS ARE ALLOWED TO DISTURB ACM (MECHANICAL TOOLS PROHIBITED FOR ACM REMOVAL).
CLEANING OF REGULATED WORK AREAS IS TO INCLUDE HEPA VACUUMING & WET WIPING METHODS. REGULATED AREAS ARE TO PASS A SUCCESSFUL VISUAL INSPECTION BY THE VPIH PRIOR TO COLLECTION OF CLEARANCE SAMPLES.
VPIH WILL PERFORM PERIMETER AIR MONITORING, VISUAL INSPECTIONS AND FINAL AIR CLEARANCE SAMPLING.
CONTRACTOR TO PERFORM OSHA EMPLOYEE EXPOSURE MONITORING.
WASTE PRODUCED DURING REMEDIATION SHALL BE COLLECTED, CONTAINERIZED, LABELED, CHARACTERIZED AND DISPOSED IN ACCORDANCE WITH ASBESTOS AND LEAD SPECIFICATIONS 02.82.11 AND 02833313.
WASTE CONTAINERS, TOOLS, EQUIPMENT, ETC. SHALL BE WET WIPED PRIOR TO LEAVING REGULATED WORK AREA.
WHERE THE COMBINED AREA OF THE NPE INCLUDING , DECONTAMINATION, LOADOUT, AND WORK CHAMBERS DOES NOT FIT WITHIN A ROOM, THE DECON/LOADOUT CONFIGURATION MAY EXTEND INTO 1/2 WIDTH OF THE HALLWAY AS REQUIRED TO ALLOW PASSAGE IN CORRIDOR
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
F r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. A-930 EXP. 12/31/2023
ENGR REG. NO. E-2586 EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENG.
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
1424 GLEN COVE DRIVE
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
COMMISSIONING
ES2
13401 N SANTA FE AVE.
OKLAHOMA CITY, OK 73114
(405) 528-4500
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
STAMP:
Drawing Number
Building Number
P
M
BUILDING 21 - FIRST FLOOR -
ENVIRONMENTAL HAZARDS
CD
05 62
JR
EHRM TRAINING AND
ADMINISTRATION SPACE
SUPPORT DESIGN
01/27/2022
589A5-21-702
COLMERY-O'NEIL VA MC
2200 SW GAGE BLVD
TOPEKA, KS 66622
HA210
1, 5, 21
SPUR #: 1794.14
No. REVISION DESCRIPTION DATE
KEY NOTES
REMOVE NON-ASBESTOS FLOOR TILE WITH UNDERLYING ASBESTOS BLACK MASTIC USING
MANUAL MEANS WITHIN NEGATIVE PRESSURE ENCLOSURE, 1,000 SF.
REMOVE SINK IN WHOLE WITH ASBESTOS CONTAINING BLACK SINK SOUNDPROOFING WITHIN
EXISTING NEGATIVE PRESSURE ENCLOSURE, 1 EACH.
ASSUMED ASBESTOS HVAC DUCT INSULATION ABOVE PLASTER CEILING, PROTECT AS
NECESSARY.
HIDDEN ASBESTOS WINDOW CAULK AND/OR GLAZE, PROTECT AS NECESSARY.
ASBESTOS TRANSITE AND/OR BLACK TAR (PACM) PRESENT IN HEAT CONVECTOR WALL POCKET,
PROTECT AS NECESSARY.
ASBESTOS BUILT-UP ROOF SYSTEM (PACM), PROTECT AS NECESSARY.
ASSUMED ORANGE LBP CEILING HANGERS, PROTECT AS NECESSARY.
A1
VISUAL KEY
ABATEMENT AREA OF FLOOR TILE WITH UNDERLYING ASBESTOS BLACK MASTIC
NEGATIVE PRESSURE ENCLOSURE
3-STAGE WET DECON CHAMBER
2,000 CFM HEPA FILTERED AIR MACHINE
DEC
AIR
A2
A3
A4
A5
A6
L1
115A
106B 106C
109A
109F
110E
111E
116P
111F
118F
119A
CDR1
121A
B
A
A5
A4
A5
A4
A4
A2
A3
A1
A3
A1
A3
A1
L1
A6
A5
A4
A5
A4
A5
A4
A5
A4
A5
A4
A5
A4 A4
A4
A4
A6
A5
A4
A5
A4
A5
A4
A4
A4
A3
BID DOCUMENTS
GENERAL NOTES
CONTRACTOR IS TO BE LICENSED TO ENGAGE IN ASBESTOS AND LEAD RELATED PROJECT WORK AND USE LICENSED/TRAINED PERSONNEL.
ABATEMENT WORK WILL REQUIRE THREE MOBILIZATIONS TO FACILITATE WORK FLOW IN ACCORDANCE WITH AN APPROVED PROJECT SCHEDULE.
WITHIN AN NPE, HVAC AIR FLOW SHALL BE SHUTDOWN AND DUCT OPENINGS COVERED WITH CRITICAL BARRIERS THROUGHOUT ABATEMENT. SCHEDULE SHUTDOWNS WITH THE VACOR TO ACCOMMODATE FACILITY AND CONSTRUCTION REQUIREMENTS.
ALL AUTHORIZED PERSONNEL WITHIN AN NPE SHALL DON, AT MINIMUM, HALF FACE AIR PURIFYING RESPIRATORS WITH P100 FILTERS, DISPOSABLE DUST SUITS (WITH BOOT AND HEAD COVERS) AND GLOVES. RESPIRATORY PROTECTION MAY REQUIRE USE OF POWERED AIR PURIFYING
RESPIRATORS.
REGULATED AREA NEGATIVE PRESSURE ENCLOSURES SHALL BE PREPARED IN ACCORDANCE WITH THE FOLLOWING:A) ALL FLOORS, CEILINGS AND WALLS SHALL BE ISOLATED USING 2-LAYERS OF 6-MIL POLY SHEETING; B) OSHA ASBESTOS SIGNAGE AT ENTRANCE TO REGULATED
AREAS; C)SINGLE-POINT OF ENTRY WITH 3-STAGE WET DECONTAMINATION STATION TO ALLOW WORKERS TO REMOVE PPE, WASH AND VACUUM THEMSELVES OFF PRIOR TO EXITING THE REGULATED WORK AREA; D) MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN WG OR BETTER)
USING HEPA FILTERED AIR MACHINES WITH EXHAUST ROUTED TO OUTDOORS; E) MINIMUM OF 4 AIR CHANGES PER HOUR; F) CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS TO CHANGE INTO STREET CLOTHES (OPAQUE POLY REQUIRED AS NEEDED FOR PRIVACY); G) RENEWABLE
ADHESIVE MATS IMMEDIATELY OUTSIDE OF REGULATED WORK AREA TO ENSURE FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO OTHER AREAS OF FACILITY.
PERFORM ABATEMENT USING THE FOLLOWING CONTROLS: A) HEPA FILTERED VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B) ONLY MANUAL REMOVAL MEANS/TOOLS ARE ALLOWED TO DISTURB ACM (MECHANICAL TOOLS PROHIBITED FOR ACM REMOVAL).
CLEANING OF REGULATED WORK AREAS IS TO INCLUDE HEPA VACUUMING & WET WIPING METHODS. REGULATED AREAS ARE TO PASS A SUCCESSFUL VISUAL INSPECTION BY THE VPIH PRIOR TO COLLECTION OF CLEARANCE SAMPLES.
VPIH WILL PERFORM PERIMETER AIR MONITORING, VISUAL INSPECTIONS AND FINAL AIR CLEARANCE SAMPLING.
CONTRACTOR TO PERFORM OSHA EMPLOYEE EXPOSURE MONITORING.
WASTE PRODUCED DURING REMEDIATION SHALL BE COLLECTED, CONTAINERIZED, LABELED, CHARACTERIZED AND DISPOSED IN ACCORDANCE WITH ASBESTOS AND LEAD SPECIFICATIONS 02.82.11 AND 02833313.
WASTE CONTAINERS, TOOLS, EQUIPMENT, ETC. SHALL BE WET WIPED PRIOR TO LEAVING REGULATED WORK AREA.
WHERE THE COMBINED AREA OF THE NPE INCLUDING , DECONTAMINATION, LOADOUT, AND WORK CHAMBERS DOES NOT FIT WITHIN A ROOM, THE DECON/LOADOUT CONFIGURATION MAY EXTEND INTO 1/2 WIDTH OF THE HALLWAY AS REQUIRED TO ALLOW PASSAGE IN CORRIDOR
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
F
DETAIL NOTES:
EXISTING RIBBED CONCRETE SLAB.
DRILL 1/4" PILOT HOLE TO FIELD LOCATE RECEPTACLE. VERIFY
PILOT HOLE HAS NOT HIT RIB OF PAN JOIST FLOOR BEFORE
PRECEEDING. IF PILOT HOLE HITS RIB, SHIFT PILOT HOLE A
DISTANCE OF (A+B/2) PERPENDICULAR TO THE RIBS.
ACCEPTABLE REGION TO LOCATE RECEPTACLE. RECEPTACLE
SHALL BE FIELD LOCATED TO AVOID RIBS.
FIELD CUT RECTANGULAR OPENING FOR RECEPTACLE BOX
AFTER ACCEPTABLE LOCATION IS CONFIRMED. DO NOT
OVERCUT CORNERS
NOTES:
ANY REBAR ENCOUNTERED WHILE DRILLING THE PILOT HOLE
SHALL NOT BE CUT. NO REBAR SHALL BE CUT UNTIL IT IS
CONFIRMED THAT THE HOLE IS NOT OVER A RIB.
RECEPTACLE BOXES SHALL NOT BE ALUMINUM.
PATCH CONCRETE AROUND RECEPTACLE AS REQUIRED
NTS
A
B th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
STRUCTURAL ENGINEER
STAND STRUCTURAL ENG.
8234 ROBINSON ST.
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
RATED ENGINEERING
1424 GLEN COVE DRIVE
EDMOND, OK 73003
(405) 856-2965
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
COMMISSIONING
ES2
13401 N SANTA FE AVE.
OKLAHOMA CITY, OK 73114
(405) 528-4500
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH RD, UNIT 1415
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
SPUR #: 1794.14
/2
/2
:2 :5
A
M
STRUCTURAL GENERAL NOTES
CGBPWS
BID DOCUMENTS
EHRM TRAINING AND
ADMINISTRATION SPACE
SUPPORT DESIGN
01/27/2022
589A5-21-702
COLMERY-O'NEIL VA MC
2200 SW GAGE BLVD
TOPEKA, KS 66622
S001
1, 5, 21
03_Abbreviation Schedule
Abbreviation Abbreviation Name
+/- PLUS OR MINUS
ADDNL ADDITIONAL
ADJ ADJACENT
AESS ARCHITECTURALLY EXPOSED
STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
AR ANCHOR ROD
ARCH ARCHITECT OR ARCHITECTURAL
B/ BOTTOM OF
B/W BETWEEN
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOT BOTTOM
BRG BEARING
BWP BRACED WALL PANEL
CFS COLD FORMED STEEL
CHKD CHECKED
CIP CAST IN PLACE
CJ CONTROL JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONT CONTINUOUS
CTR CENTER
db DIA OF REINF BAR, DIA OF BOLT
DBA DEFORMED BAR ANCHOR
DIA or Ø DIAMETER
DIAG DIAGONAL
DIR DIRECTION
DWL DOWEL
EA EACH
EE EXTENDED END
EJ EXPANSION JOINT
ELEV ELEVATION
ENGR ENGINEER
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL
EW EACH WAY
EXIST EXISTING
EXT EXTERIOR
FDN FOUNDATION
FLG FLANGE
FLR FLOOR
FS FAR SIDE
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GALV GALVANIZED
GB GRADE BEAM
GC GENERAL CONTRACTOR
HORIZ HORIZONTAL
HSA HEADED STUD ANCHOR
HSS HOLLOW STRUCTURAL SECTION
IF INSIDE FACE
INT INTERIOR
JST JOIST
K KIPS (1000 LBS)
LCE COMPRESSION EMBEDMENT LENGTH
LCS COMPRESSION LAP SPLICE LENGTH
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LTE TENSION EMBEDMENT LENGTH
LTS TENSION LAP SLICE LENGTH
LW LIGHTWEIGHT
MFCR MANUFACTURER
MTL METAL
NIC NOT IN CONTRACT
NS NEAR SIDE
NTS NOT TO SCALE
OC ON CENTER
OF OUTSIDE FACE
OPP OPPOSITE
OVS OVERSIZED
P/C PRECAST
PAF POWDER ACTUATED FASTENER
PAR PARALLEL
PEMB PRE-ENGINEERED METAL BUILDING
PEN PENETRATION
PERP PERPENDICULAR
PL PLATE
PLF POUNDS PER LINEAR FOOT
PREFAB PREFABRICATED
PRELIM PRELIMINARY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
RC REINFORCED CONCRETE
RE: REFER TO
REINF REINFORCING
REQD REQUIRED
RF RIGID FRAME
SC SLIP CRITICAL
SDS SELF DRILLING SCREW
SIM SIMILAR
SLV SHORT LEG VERTICAL
SOG SLAB ON GRADE
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STIR STIRRUPS
STL STEEL
SW SHEAR WALL
SYM SYMMETRIC
T&B TOP AND BOTTOM
T/ TOP OF
TRANS TRANSVERSE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
W/ WITH
W/O WITHOUT
WF WIDE FLANGE
WP WORK POINT
WWR WELDED WIRE REINFORCEMENT
STRUCTURAL DESIGN CRITERIA (2021 IBC AND ASCE 7-16):
STRUCTURAL GENERAL NOTES:
1. DESIGN AND CONSTRUCTION SHALL CONFORM TO THE "INTERNATIONAL
BUILDING CODE, 2021 EDITION". REFER TO THE SPECIAL STRUCTURAL INSPECTION
NOTES FOR ADDITIONAL REQUIREMENTS.
2. CONTRACTOR TO VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING
CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO
COMMENCING WORK.
3. IF DISCREPANCIES EXIST BETWEEN STRUCTURAL PLANS, ARCHITECTURAL
PLANS, OTHER PLANS, OR SPECIFICATIONS, THE CONTRACTOR OR
SUBCONTRACTOR SHALL PROVIDE A WRITTEN REQUEST FOR CLARIFICATION FROM
THE ARCHITECT AND/OR ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
4. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER
THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S
RESPONSIBILITY TO EXECUTE AND DETERMINE FINAL ERECTION PROCEDURES,
SEQUENCING AND TO ENSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT
PARTS DURING ERECTION. THIS INCLUDES WHATEVER SHORING, SHEETING,
TEMPORARY BRACING, GUYING OR TIE DOWNS WHICH MIGHT BE NECESSARY.
5. FABRICATORS AND SUPPLIERS SHALL CLEARLY NOTE AND HIGHLIGHT CHANGES
MADE IN SHOP DRAWINGS, WHICH DO NOT COMPLY WITH THE CONTRACT
DOCUMENTS.
6. COLUMNS, BEAMS, JOISTS, OR TRUSSES SHALL NOT BE FIELD CUT OR TRIMMED
FOR ANY REASON WITHOUT THE WRITTEN APPROVAL OF THE
ARCHITECT/ENGINEER.
8. HOLES, PIPES, SLEEVES, ETC. NOT SHOWN ON THE DRAWINGS MUST BE
REVIEWED BY THE ARCHITECT/ENGINEER BEFORE PLACEMENT THROUGH
STRUCTURAL MEMBERS.
9. IF MECHANICAL AND ELECTRICAL EQUIPMENT SIZES, OR LOCATIONS DO NOT
COINCIDE WITH EQUIPMENT SHOWN ON THE PLANS, COORDINATE ADJUSTMENTS
WITH THE ARCHITECT.
10. NO AREA OF THE STRUCTURE SHALL BE LOADED WITH CONSTRUCTION
MATERIALS OR EQUIPMENT THAT EXCEEDS FINAL DESIGN CRITERIA.
1 1/2" = 1'-0"
FLOOR RECEPTACLE1
No. REVISION DESCRIPTION DATE
1/27/2022 06 62
UP
DN
UP
UP
UP
UP
UP
DN
UP UP
UPUP
UP
1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT
WALL UNLESS NOTED OTHERWISE.
This is the start of the file's text. The full file is on GovTribe.