This document is a detailed engineering drawing and specification for a precast concrete pad (Part Number 100002190) designed by Jensen Precast. The pad is a rectangular concrete structure with specific dimensional specifications: 5'-0" long, 2'-6" wide, and 1'-0" deep, with an approximate weight of 1,530.67 lbs. Key technical specifications include a 28-day concrete compressive strength of 5000 PSI, reinforcing steel complying with ASTM A615 or A706 Grade 60 standards, and designed for a loading specification of A-03 (300 psf). The drawing includes a bill of materials listing concrete mix, anchor dogbone, reinforcing mat, and insert ferrule loop components, along with detailed lifting instructions specifying a 1500 PSI lift with 4 lift connections at a minimum 60° sling angle. The document also provides technical details about soil unit weights, lateral pressures, and installation requirements for the precast concrete pad.

View the file

Other files

File Type Posted
Attachment 3 - Vault Design.pdf PDF
Attachment 1 - Items List and Specifications.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLAN VIEW

SECTION A-A SECTION B-B

A A

B

B

BILL OF MATERIALS

DESCRIPTIONPART NUMBERQTYUNIT QTYITEM

CONCRETE MIX GENERIC 5000 PSI10001142510.171 ft^310.171 ft^31

ANCHOR DOGBONE P52 2T X 3-3/8" GALV100002867412

REINFORCING MAT 300127324300127324213

INSERT FERRULE LOOP 1/2 X 2-3/4 PLATED FX-5100002765414

0.

id w

SHEET:

REV:

B-1

4/16/2021 5/7/2021MODIFIED:CREATED:

PART NUMBER: DRAWN BY:

DESCRIPTION:

Pad 3258x12 NVE 24-0721

LIFTING TYPE:REINFORCEMENT

TYPE:

DESIGN SPEC: LOADING SPEC:

BURY DEPTH:

WWW.JENSENPRECAST.COM

Above Ground to N/A

WATER LEVEL:

A-03 (300 psf)

Below Structure APPROX. WEIGHT: 1530.67 Lbs

100002190 B. Gentry-Dunn DogboneRebar

Agency Specified

©2021 Jensen Precast- All rights reserved.

All materials appearing as Jensen Precast documents and the like are proprietary work product and are protected under U.S. copyright and other laws.

Unless in conjunction with business conducted with Jensen Precast, any use of Jensen Precast work product without express, written consent is prohibited, and recipient is prohibited from distributing any and all work product to non-approved third parties under penalty of civil action.

CASTING LAYOUT

NOTES

■ FOR COMPLETE DESIGN AND PRODUCT INFORMATION CONTACT JENSEN PRECAST.

LIFTING NOTES

■ THIS CONCRETE PRODUCT IS DESIGNED TO BE LIFTED AT 1500PSI WITH 4 LIFT

CONNECTIONS EQUALLY LOADED TO 2 LIFTING POINTS AT A MINIMUM 60° SLING ANGLE,

MEASURED FROM HORIZONTAL.

CHANGE HISTORY

REV DESCRIPTION DATE BY

A INITIAL RELEASE

B 2104-50756 UPDATED PER NVE SPEC 4/20/2021 BGD

2'-6" [30.00 in]

4'-10" [58.00 in]

1'-0" [12.00 in]

5'-0" [60.00 in]

2'-8" [32.00 in]

1'-4" [16.00 in]

2'-10" [34.00 in]

1 1/2"

TYP

1 1/2"

TYP

6"

TYP

6"

TYP 4

PLAN VIEW

SECTION C-CSECTION D-D

D

D

C C

0.

id w

SHEET:

REV:

B-1

4/16/2021 5/7/2021MODIFIED:CREATED:

PART NUMBER: DRAWN BY:

DESCRIPTION:

Pad 3258x12 NVE 24-0721

LIFTING TYPE:REINFORCEMENT

TYPE:

DESIGN SPEC: LOADING SPEC:

BURY DEPTH:

WWW.JENSENPRECAST.COM

Above Ground to N/A

WATER LEVEL:

A-03 (300 psf)

Below Structure APPROX. WEIGHT: 1530.67 Lbs

100002190 B. Gentry-Dunn DogboneRebar

Agency Specified

©2021 Jensen Precast- All rights reserved.

All materials appearing as Jensen Precast documents and the like are proprietary work product and are protected under U.S. copyright and other laws.

Unless in conjunction with business conducted with Jensen Precast, any use of Jensen Precast work product without express, written consent is prohibited, and recipient is prohibited from distributing any and all work product to non-approved third parties under penalty of civil action.

REINFORCING CAGE REVIEW

• ALL CONCRETE TO HAVE A 28 DAY COMPRESSIVE STRENGTH OF 5000 PSI.

• REINFORCING STEEL SHALL COMPLY WITH ASTM A615 GRADE 60 OR ASTM A706 GRADE 60. BAR BENDING

AND PLACEMENT SHALL COMPLY WITH THE LATEST ACI STANDARD. EQUIVALENT AREA WELDED WIRE

REINFORCEMENT CAGES MAY BE UTILIZED IN LIEU OF GRADE 60 REINFORCING BARS.

• WELDED WIRE REINFORCEMENT SHALL COMPLY WITH ASTM A1064 GRADE 80 STANDARDS

• LIFTING INSERTS FOR HANDLING SHALL BE INSTALLED PER MANUFACTURER'S REQUIREMENTS.

• BURY DEPTH Above Ground TO N/A

• WATER LEVEL: Below Structure

• DESIGN SPECIFICATION: Agency Specified

• LOADING SPECIFICATION: A-03 (300 psf)

• SOIL UNIT WEIGHT DRY - 110 lbs/cu.ft.

• EQUIVALENT LATERAL PRESSURE DRY - 40 lbs/cu.ft.

• SOIL UNIT WEIGHT WET - 120 lbs/cu.ft.

• EQUIVALENT LATERAL PRESSURE WET - 80 lbs/cu.ft.

1 1/2"

CLR

1 1/2"

CLR

1 1/2"

CLR