EAST BRANCH CLARION RIVER
SPILLWAY SAFETY FENCE
PROJECT LOCATION AND VICINITY MAP
AND WORK AREA LIMITS
DWG EBR FENCE-01
SPILLWAY SAFETY FENCE WORK AREA LIMITS
PROJECT LOCATION AND VICINITY MAP
WORK AREA
NOTES
1. FOR THE CONTRACTOR’S INFORMATION, THE AREA
DOWNSTREAM OF THE SPILLWAY IS NOT ACCESSIBLE
BY EQUIPMENT TO THE CONSTRUCTION SITE DUE TO
THE AREA BEING PERPETUALLY WET AND SOGGY.
2. THE SITE IS, IN GENERAL, STEEP AND DIFFICULT TO AC-
CESS. FENCE ALIGNMENT TERRAIN AND CROSS SEC-
TION INFORMATION HAS BEEN PROVIDED WITH THE
SPECIFICATIONS.
3. THE CONTRACTOR SHALL BE REQUIRED TO SUBMIT A
SITE ACCESS AND WORK PLAN FOR APPROVAL THAT
CLEARLY SHOWS HOW THE CONTRACTOR INTENDS TO
PERFORM THE WORK IN ACCORDANCE WITH THE SPECI-
FICATIONS.
EAST BRANCH CLARION RIVER
SPILLWAY SAFETY FENCE
FENCE ALIGNMENT AND GENERAL NOTES
DWG EBR FENCE-02
NOTES
1. THE TERRAIN ABOVE THE CONCRETE SPILLWAY
IS STEEP AND UNPROTECTED. PURPOSE OF
FENCE IS TO PREVENT PUBLIC AND DEER FROM
FALLING INTO THE SPILLWAY.
2. THE PROPOSED ALIGNMENT SHOWN IS ALONG A
BENCH ABOVE THE SPILLWAY.
3. SEE SPECIFICATIONS AND FENCE DETAIL
DRAWING FOR ADDITIONAL FENCE REQUIRE-
MENTS.
4. PROPOSED ALIGNMENT IS ONLY APPROXIMATE.
ACTUAL ALIGNMENT SHALL BE DETERMINED IN
THE FIELD IN THE PRESENCE OF THE ACO OR
DESIGNATED REPRESENTATIVE.
5. LINE POST SPACING SHALL BE A MAXIMUM OF
20 FEET.
6. POST SPACING AND ALIGNMENT SHALL BE AD-
JUSTED TO COMPENSATE FOR TERRAIN OR OB-
STACLES AND TO MINIMIZE NEED FOR BRACING.
7. THE CONTRACTOR IS RESPONSIBLE FOR DETER-
MINING APPROPRIATE EQUIPMENT AND CON-
STRUCTION METHODS TO PERFORM THE WORK
IN A SAFE MANNER.
8. AN AREA BETWEEN 8AND 10 FEET WIDE HAS
BEEN CLEARED OF BRUSH AND SMALL TREES
ALONG THE FENCE ALIGNMENT.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
ANY ADDITIONAL CLEARING DUE TO REGROWTH
OF VEGETATION OR FOR ANY ADDITIONAL
CLEARING REQUIRED TO COMPLETE THE WORK.
10. GATES SHALL BE INSTALLED AT THE APPROXI-
MATE LOCATIONS SHOWN AS AGREED TO BY
THE ACO. GATES SHOULD BE LOCATED AT A
CORNER TO MINIMIZE NEED FOR ADDITIONAL
BRACING.
APPROX. LOCATION
OF GATES
APPROX. FENCE
ALIGNMENT
SPILLWAY SAFETY FENCE ALIGNMENT
DAM
SPILLWAY
WIRE
STRAINER
6” DIA. TREATED
POST
4” DIA. TREAT-
ED POST
12.5 GA HIGH TENSILE
BRACE WIRE
6” DIA. TREATED
POST
PIN PIN
GRADE
10’ SPACING
TYPICAL DOUBLE BRACING (DOUBLE H-BRACE)
(REQUIRED MAX EVERY 1,000 FT)
23/96/6, 12½ GA
WOVEN WIRE
FABRIC
EAST BRANCH CLARION RIVER
SPILLWAY SAFETY FENCE
FENCE DETAILS
DWG EBR FENCE-03
M
A X
GRADE
ON-SITE SOIL FILL
MAY NEED TO BE
GRADED TO SUIT
TERRAIN
6” DIA. TREATED LINE
POST
TERRAIN ADJUSTMENTS
20’ MAX SPACING
4” DIA. TREATED
LINE POST
TYPICAL LINE POST SPACING
20’ MAX SPACING
(MAY NEED TO BE ADJUST TO SUIT TERRAIN)
23/96/6, 12½ GA
WOVEN WIRE
FABRIC
NOTES
1. WOODEN LINE POSTS SHALL BE MIN 4“ DIAMETER OR 6”X6”
SQUARE (NOMINAL).
2. END, CORNER AND DOUBLE BRACING POSTS SHALL BE MIN 6”
DIAMETER OR 8”X8” (NOMINAL).
3. ALL HARDWARE, WIRE, FASTENERS, BOLTS, GATE AND GATE COM-
PONENTS SHALL BE HOT-DIPPED GALVANIZED STEEL.
4. ALL POSTS SHALL BE SET A MINIMUM OF 36“ BY MECHANICALLY
DRIVING OR AUGURING. AUGURED HOLES SHALL BE BACKFILLED
WITH COMPACTED CRUSHED STONE AGGREGATE, CONFORMING
TO PENNDOT 2A OR 2RC.
5. CONTRACTOR MAY SUBMIT FOR APPROVAL ALTERNATIVE MATERI-
ALS SUCH AS GALVANIZED STEEL POSTS OR ALTERNATIVE SYS-
TEMS, SUCH AS STEEL POSTS AND STEEL POST SLEEVES. ALTER-
NATES MAY BE APPROVED IF FENCE HEIGHT OF 8 FT IS MAIN-
TAINED AND INCLUDES THE GATES AS SHOWN.
WIRE
STRAINER
6” DIA. TREATED
POST
4” DIA. TREAT-
ED POST
12.5 GA HIGH TENSILE
BRACE WIRE
6” DIA. TREATED
POST
PIN PIN
PULL OF FABRIC
GRADE
10’ SPACING
TYPICAL END BRACING (H-BRACE)
(REQUIRED AT ALL CORNERS, ENDS AND GATES)
TYPICAL CORNER BRACING
(DOUBLE H-BRACE) ISOMETRIC VIEW
(REQUIRED WHERE THE ALIGNMENT CHANGES 15 DEGREES OR MORE)
SEE TYPICAL END BRACING DETAIL FOR ADDITIONAL REQUIREMENTS
6” DIA. TREATED
POSTS
12.5 GA HIGH
TENSILE
BRACE WIRES
23/96/6, 12½ GA
WOVEN WIRE
FABRIC
4” DIA. TREATED
POST
4” DIA. TREATED
LINE POST
TYPICAL 4’-0” WIDE X 7-6” HIGH GATE DETAIL
J-HOOK HINGE BOLTS AND
HINGE WITH NUTS AND
WASHERS FOR MOUNTING
TO POST. LAG BOLTS NOT
ALLOWED.
MIN. 1-3/4” DIA GALVANIZED
TUBE FRAME
6”X6”X6 Ga/6 Ga
GALVANIZED WIRE FABRIC,
WELDED TO GATE FRAME
6” MAX GROUND
EAST BRANCH CLARION RIVER
SPILLWAY SAFETY FENCE
END, CORNER AND GATE DETAILS
DWG EBR FENCE-04
HEAVY DUTY
GALVANIZED TWO-WAY
LOCKABLE SLAM LATCH
(SEE SPECIFICATIONS)
6” DIA. TREATED
POST
NOTES
1. SEE DRAWING EBR FENCE-03 FOR ADDITIONAL NOTES AND
DETAILS
GATE
6” DIA. TREATED POST
M
A X