This is a Technical and Packaging Requirements attachment for a US Coast Guard Aviation Logistics Center Request for Quotation (RFQ 70Z03826QJ0000323) for the procurement of special purpose cable. The document establishes mandatory technical and quality standards that all offerors must satisfy and confirm through checkbox acknowledgments submitted with their quotations.

Offerors must demonstrate the ability to provide manufacturer company information, CAGE codes, coating types, and strand specifications for wire orders. All wire and cable must be manufactured and inspected in accordance with SAE standards, accompanied by the manufacturer's Quality Assurance Testing Report including finished wire resistance checks and OEM data sheets. A Certificate of Conformance (COC) per FAR 52.246-15 is required to verify airworthiness and suitability for USCG aircraft installation. All wire must be newly manufactured and approved, marked in accordance with SAE AS22759 and/or NAVAIR 01-1A-505-1 standards with part numbers and manufacturer CAGE codes, manufactured within the last 12 months, and delivered as full continuous spools with no breaks or multiple segments. Each spool must be clearly identified with spool numbering, National Stock Number, part number, manufacturer lot number, and manufacturing date. Wire marking requirements specify spacing every 6 to 60 inches in black or green lettering, with exceptions for contrast purposes; wire 26 gauge and smaller is exempt from marking requirements. Quality Assurance requires access to both spool ends for inspection, with proper termination using heat shrink on bitter ends. Offerors must specify FOB shipping point and estimated shipping costs if FOB Origin is claimed; all quotes are considered FOB Destination unless otherwise stated. Failure to submit requested attachments or non-compliance with any technical and packaging requirement will result in an unacceptable technical rating and elimination from further evaluation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1 Attachment 2 - Technical and Packaging Requirements -

70Z03826QJ0000323

US COAST GUARD
AVIATION LOGISTICS CENTER
ELIZABETH CITY, NC 27909-5001
All offerors MUST be able to satisfy all the technical and packaging requirements as outlined below. Confirmation must be provided by checking all the boxes below and submitting with the quotation. Failure to submit the requested attachments will result in an "unacceptable" rating for technical acceptability and the offerors quote will not be further evaluated.
FALSEOfferors must be able to provide the Manufacturer Company, Cage Code, type of coating applied to the wire, and number of strands and strand size applicable to wire order.
FALSEWire and Cable shall be manufactured and inspected in accordance with (IAW) SAE Standards per wire/cable. Please include manufacturer’s Quality Assurance Testing Report including “Finished Wire Resistance Check”, OEM’s Data Sheet, and results of the test IAW SAE specifications with shipment.
FALSEThe Contractor shall furnish a Certificate of Conformance (COC) in accordance with Federal Acquisition Regulation (FAR) clause 52.246-15. COC must be submitted in the format specified in the clause. Offerors must be able to provide necessary certification including traceability to the manufacturer, manufacturer's (COC) to ensure parts are in airworthy condition, suitable for installation on USCG aircraft.
FALSEAll wire shall be NEW approved wire. The Contractor shall provide documentation with a statement verifying that all wire shall be NEW approved wire, in response to this RFQ. (For example, no wire outer insulation containing PVC), for this wire would be disqualifying for aerospace standards.
FALSEEach reel of wire shall be a full spool when possible. Spools shall be a continuous run with no break. Multiple segments per spool are not authorized and will be rejected by Quality Assurance. Wire must be marked IAW SAE AS22759 and/or NAVAIR 01-1A-505-1 and manufactured within last 12 months.
FALSEWire and Cable marking should show the part number (e.g., M22759/12-20-9) and manufacturer Cage Code (e.g., 12ABC). Marking is typically every 12 inches, but may be every 6 to 60 inches apart, in black or green color. (Exception to include when outer jacket requires a stark contrast to identify wire number, such as black jacket and white lettering). The lack of proper marking is reason for rejection. NOTE: Wire size 26 gauge and smaller does not require marking. The date of manufacture shall be listed on every spool data label as well as the type of coating applied to the wire.
FALSEQA requires access to both ends of Wire and Cable on the spool for inspection. All Wire and Cable must be terminated correctly, for example, heat shrink on bitter end of wire. Each spool of wire needs to be identified with (example: 1 of 6, or use manufacturers assigned name), National Stock Number, Part Number, manufacturer lot number of wire order, and date of manufacturer listed on tag of spool (usually the wire comes with the manufacturers assigned name “LRB” already designated on the spool).
FALSEThe FOB Shipping Point (Destination or Origin) and Estimated Shipping Cost if FOB Origin. All quotes will be considered FOB Destination unless FOB Origin is clearly stated, and shipping costs are included.
FALSEOfferors acknowledge that any wire that is delivered and that does not adhere to these technical and packaging requirements may fail inspection and be rejected by Quality Assurance.
COMPANY:
CAGE:
CONTACT: