Attachment 2 - BBEC Iron Gate Fence Specifications - 20240624.pdf
PDF 101 KB Posted
- Attached to
- BBEC Iron Gate Replacement Federal contract opportunity
- Solicitation number
- FA301024Q0032
About this file
This document appears to be the Attachment 2 - Salient Characteristics for the BBEC Iron Gate Fence Specifications at Keesler AFB, MS. It outlines the requirements for a steel gate to replace the existing gate at the loading dock northeast end of the Bay Breeze Event Center. The gate must be black in color, manually operated, and able to withstand diverse weather conditions. The main gate should be 10'6" high x 162" wide, and the employee gate should be 10'6" high x 4' wide, both installed on existing posts using sealed bearing hinges. The gate will be delivered to and installed at the Bay Breeze Event Center on Keesler AFB.
The related federal contract opportunity is for the BBEC Iron Gate Replacement project, a total small business set-aside with an estimated magnitude between $25,000 and $100,000. The solicitation number is FA301024Q0032, and the contract will be issued by the Department of the Air Force Air Education and Training Command. A site visit has been scheduled for August 28, 2024, and bidders are directed to Sections L and M for quote preparation and evaluation factors.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 8 - BBEC Iron Gate Drawing - 20240910.pdf | ||
| Solicitation Amendment FA301024Q00320003 SF 30.pdf | ||
| Solicitation Amendment FA301024Q00320002 SF 30.pdf | ||
| Solicitation Amendment FA301024Q00320001 SF 30.pdf | ||
| Solicitation Amendment - FA301024Q00320001.pdf | ||
| Attachment 1 - BBEC Iron Gate SOW - 20240722.pdf | ||
| Solicitation - FA301024Q0032.pdf | ||
| Attachment 3 - BBEC Iron Gate Wage Determination 20240050 - 20240621.pdf | ||
| Attachment 5 - BBEC Iron Gate MSS - 20240823.xlsx | XLSX spreadsheet | |
| Attachment 7 - BBEC Iron Gate PPRL - 20240823.pdf | ||
| Attachment 4 - BBEC Iron Gate Submittal Procedures - 20240823.pdf | ||
| Attachment 6 - BBEC Iron Gate Past Performance Questionnaire - 20240823.docx | DOCX document |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Salient Characteristics
Loading Dock Gate
Keesler AFB, MS Bay Breeze Event Center
1. Requirements/Specifications
• Steel Gate, black in color to replace gate at loading dock northeast end of Event Center
GATES NEED TO MANUALLY OPEN AND CLOSE FOR DELIVERY TRUCKS
TO ENTER LOADING DOCK
MUST BE ABLE TO WITHSTAND DIVERSE/ADVERSE WEATHER
CONDITIONS.
MAIN GATE SHOULD BE SAME OR EQUAL TO BLACK IRON / BA STEEL
10'6 HIGHT X 162" WIDE, INSTALLED ON EXISTING POSTS USING SEALED
BEARING HINGES.
EMPLOYEE GATE SHOULD BE SAME OR EQUAL TO BLACK IRON/ BA
STEEL 10'6 HIGHT X 4' WIDE, INSTALLED ON EXISTING POSTS USING
SEALED BEARING HINGES.
2. Delivery Location The gate will be delivered to and installed at Bay Breeze Event Center, 500 Ploesti Dr. Keesler
AFB, MS 39534
| Text3: FA201024Q0032 |
| Text4: Attachment 2 - Salient Characteristics |