This document provides details for an advanced notice of a forthcoming solicitation for the Building 7 Renovation project at the Spokane Veterans Affairs Medical Center. The solicitation number will be 36C26024R0019 and will be posted shortly by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 20. The advanced notice includes drafts of the solicitation documentation and drawings of the building to be renovated. The forthcoming solicitation will seek bids for renovations to upgrade Building 7 at the Spokane VA Medical Center campus.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AESUS DESIGN GROUP PROJECT NO. 21010MANN-GRANDSTAFF VA MEDICAL CENTER, SPOKANE, WA

VA PROJECT # 668-21-101

OFFICE OF CONSTRUCTION

AND FACILITIES MANAGEMENT

Department of Veterans Affairs

BID SET SUBMITTAL DOCUMENTS

AESUS DESIGN GROUP

RENOVATE BUILDING 7 - MENTAL HEALTH

APRIL 7, 2023

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center

4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS

G.002

PROJECT INFORMATION

DX

A3-301

X

XX

X

DETAIL FLAG NUMBER

DOOR NUMBER

AE-501

BUILDING SECTION CUT

OTHER SECTION CUT

SHEET WHERE APPEARS (TYPICAL)

AE-301

AA

SHEET WHERE APPEARS

ELEVATION NUMBER

SHEET WHERE APPEARS

x x x x

EXISTING COLUMN CENTER LINEA

X

WINDOW TAG

AE-301

AA

AE-301

AA

ELEVATION NUMBER

AE-710

4 2

DASHED LINE

AROUND

AREA DETAILED

PLAN OR DETAIL NUMBERX

NOTE: IN ADDITION TO THE FOLLOWING INFECTION CONTROL MEASURES, THE

CONTRACTOR SHALL REVIEW THE VA SAFETY-QUALITY CONTROL-INFECTION

CONTROL DOCUMENTS IN THE SPECIFICATIONS. THE VA WILL PROVIDE A FORM

FOR THE CONTRACTOR TO FILL OUT

DURING CONSTRUCTION:

A. ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT

CONTAMINATION OF DUCT SYSTEM.

B. COMPLETE ALL CRITICAL BARRIERS I.E. SHEET ROCK, PLYWOOD, PLASTIC,

TO SEAL AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE

METHOD (CART WITH PLASTIC COVERING AND SEALED CONNECTION TO

WORK SITE WITH HEPA VACUUM FOR VACUUMING PRIOR TO EXIT) BEFORE

CONSTRUCTION BEGINS.

C. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA

EQUIPPED AIR FILTRATION UNITS. PROVIDE NEGATIVE AIR PRESSURE

MONITOR.

D. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES APPROPRIATELY.

E. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH

THIS ROOM SO THEY CAN BE VACUUMED USING A HEPA VACUUM CLEANER

BEFORE LEAVING WORK SITE OR THEY CAN WEAR CLOTH OR PAPER

COVERALLS THAT ARE REMOVED EACH TIME THEY LEAVE THE WORK SITE.

F. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT

IS INSPECTED BY A SAFETY OFFICER AND INFECTION CONTROL

COORDINATOR AND THOROUGHLY CLEANED BY THE ENVIRONMENTAL

MANAGEMENT SERVICES.

UPON COMPLETION OF PROJECT:

A. REMOVE BARRIER MATERIAL CAREFULLY TO MINIMIZE SPREADING OF DIRT

AND DEBRIS ASSOCIATED WITH CONSTRUCTION.

B. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY

COVERED CONTAINERS.

C. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS

SOLID LID.

D. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS.

E. WET MOP AREA WITH DISINFECTANT.

F. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS WHERE WORK IS BEING

PERFORMED.

Approved: Associate Director

Approved: Chief Facilities Management

Approved: Manager / Engineer

Approved: Director

Approved: Union representative

Approved: Safety Officer

EQ-X

CPT1

W-X

E

EA EACH

E EAST

EWC ELECTRIC WATER COOLER

ELEC ELECTRIC (AL)

EL ELEVATION

ELEV ELEVATOR

EMER EMERGENCY

ENGR ENGINEER

EQ EQUAL

EQUIP EQUIPMENT

EXIST EXISTING

ETR EXISTING TO REMAIN

EXP EXPANSION

EXP BT EXPANSION BOLT

EJ EXPANSION JOINT

EXP EXPOSED

EXT EXTERIOR

EIFS EXTERIOR INSULATION AND

FINISH SYSTEM

F

FWC FABRIC WALL COVERING

FT FEET, FOOT

FGL FIBERGLASS

FIN FINISH

FIN GR FINISH GRADE

FDV FIRE DEPARTMENT VALVE

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER

CABINET

FHC FIRE HOSE CABINET

FP FIREPROOF

FIXT FIXTURE

FLASH FLASHING

FLEX FLEXIBLE

FLR FLOOR

FD FLOOR DRAIN

FLUOR FLUORESCENT

FTG FOOTING

FDTN FOUNDATION

FRMG FRAMING

FURN FURNACE, FURNITURE

G

GA GAGE

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GL GLASS

GL BLK GLASS BLOCK

GB GRAB BAR

GR GRADE

GRAN GRANITE

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GUT GUTTER

GYP BD GYPSUM BOARD

H

HNDRL HANDRAIL

HDW HARDWARE

HDWD HARDWOOD

HD HEAD

HVAC HEATING, VENTILATING, AIR CONDITIONING

HT HEIGHT

HPT HIGH POINT

HC HOLLOW CORE

HM HOLLOW METAL

HORIZ HORIZONTAL

HB HOSE BIBB

HOSP HOSPITAL

HR HOUR

I

IN INCH

INFO INFORMATION

ID INSIDE DIAMETER

INSUL INSULATED,INSULATION

INT INTERIOR

J

JAN JANITOR

JT JOINT

K

KPL KICKPLATE

KIT KITCHEN

KB KNEE BRACE

L

LAB LABORATORY

LAM LAMINATE

LC LAUNDRY CHUTE

LV LAVATORY

LT LIGHT

LD LINEAR DIFFUSER

L CL LINEN CLOSET

LL LIVE LOAD

LLV LONG LEG VERTICAL

LPT LOW POINT

M

MACH MACHINE

MH MANHOLE

MFD MANUFACTURED

MFR MANUFACTURER

MRB MARBLE BASE

MRF MARBLE FLOOR

MKR BD MARKER BOARD

MO MASONRY OPENING

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MED MEDICAL

MC MEDICINE CABINET

MEMB MEMBRANE

MTL METAL

MIN MINIMUM, MINUTE

MISC MISCELLANEOUS

MOD MODIFIED

MLDG MOLDING

N

NAT FIN NATURAL FINISH

NOM NOMINAL

N NORTH

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NTS NOT TO SCALE

NO NUMBER

O

OFF OFFICE

OC ON CENTER

OPNG OPENING

OPP OPPOSITE

OPH OPPOSITE HAND

ORCH ORCHESTRA

ORN ORNAMENTAL

OD OUTSIDE DIAMETER

OH OVERHANG, OVERHEAD

OF/CI OWNER FURNISHED/

CONTRACTOR INSTALLED

O OXYGEN

P

P PAINT

PR PAIR

PNL PANEL

PTD PAPER TOWEL DISPENSER

PTN PARTITION

PERF PERFORATED

PC PIECE

PLAM PLASTIC LAMINATE

PLAS PLASTIC, PLASTER

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PCC PRECAST CONCRETE

PREFAB PREFABRICATE

PREFIN PREFINISH

PROD PRODUCTION

Q

QTY QUANTITY

QT QUARRY TILE

A

AFF ABOVE FINISHED FLOOR

ACST ACOUSTIC (AL)

ACT ACOUSTICAL CEILING TILE

APC ACOUSTICAL PANEL CEILING

AWP ACOUSTICAL WALL PANEL

AWT ACOUSTICAL WALL

ADJ ADJUSTABLE

A/C AIR CONDITIONING

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

AB ANCHOR BOLT

AL ANGLE

APPROX APPROXIMATE

ARCH ARCHITECT (URAL)

ASPH ASPHALT

ASSY ASSEMBLY

AUTO AUTOMATIC

AWN AWNING

B

BALC BALCONY

BSMT BASEMENT

BM BEAM, BENCHMARK

BR BEDROOM

BLKG BLOCKING

BD BOARD

BOT BOTTOM

BRKT BRACKET

BRK BRICK

B CL BROOM CLOSET

BLDG BUILDING

BLT IN BUILT-IN

BUR BUILT-UP ROOFING

C

CAB CABINET

CPT CARPET

CSMT CASEMENT

CI CAST IRON

CB CATCH BASIN

CLG CEILING

CEM CEMENT

CL CENTER LINE

CER CERAMIC

CT CERAMIC TILE

CO CLEANOUT, CASED OPENING

CLR CLEAR, COLOR

CLO CLOSET

COL COLUMN

CMPST COMPOSITE

CONC CONCRETE

CMU CONCRETE MASONRY UNIT

CONSTR CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACTOR

COTR CONTRACTING OFFICER

CJ CONTROL JOINT

COP COPING

CU COPPER

CG CORNER GUARD

CORR CORRIDOR

CNTR COUNTER

CSK COUNTER SUNK

D

DMPF DAMPPROOFING

DL DEAD LOAD

DEMO DEMOLITION

DET DETAIL

DIA DIAMETER

DIFF DIFFUSER

DIM DIMENSION

DR DOOR, DRAIN

DH DOUBLE HUNG

DN DOWN

DS DOWNSPOUT

DWR DRAWER

DWG DRAWING

DF DRINKING FOUNTAIN

DUPL DUPLICATE

R

R RADIUS, RISER

RWD REDWOOD

REF REFERENCE, REFRIGERATOR

REINF REINFORCE

REQD REQUIRED

RB RESILIENT BASE

RF RESILIENT FLOORING

RA RETURN AIR

REV REVISION

RD ROOF DRAIN

RM ROOM

RO ROUGH OPENING

RS ROUGH SAWN

S

SCHED SCHEDULE

SECT SECTION

SHTHG SHEATHING

SHT SHEET

SHV SHELVING

SIM SIMILAR

S SOUTH

SP FIN SPECIAL FINISH

SPEC SPECIFICATION

SQ SQUARE

SF SQUARE FEET

SST STAINLESS STEEL

STD STANDARD

STL STEEL

STL JST STEEL JOIST

STOR STORAGE

STRUCT STRUCTURAL

S4S SURFACED FOUR SIDES

SUSP SUSPEND

SW SWITCH

SYMM SYMMETRICAL

T

TK BD TACKBOARD

TEL TELEPHONE

TV TELEVISION

TMPD TEMPERED

TEMP TEMPORARY

TER TERRAZZO

THK THICKNESS

TPD TOILET PAPER DISPENSER

T&G TONGUE AND GROOVE

TOS TOP OF SLAB, STEEL

T TREAD

TYP TYPICAL

U

UC UNDERCUT

UNFIN UNFINISH

UNO UNLESS NOTED OTHERWISE

V

VAC VACUUM

VR VAPOR RETARDER

VNR VENEER

VP VENEER PLASTER

VIF VERIFY IN FIELD

VERT VERTICAL

VEST VESTIBULE

VCT VINYL COMPOSITION TILE

VWC VINYL WALL COVERING

W

W CAB WALL CABINETS

WC WALL COVERING, WATER CLOSET

WP WATERPROOFING, WEATHER

WT WEIGHT

WWF WELDED WIRE FABRIC

W WEST

WF WIDE FLANGE

WDW WINDOW

W/ WITH

W/O WITHOUT

WD WOOD

WDP WOOD PANELING

4815 ASSEMBLY ST.

Department of Veterans Affairs

KEYED NOTE

WALL TYPE

X

X WINDOW TREATMENT TYPE

EQUIPMENT

INTERIOR FINISH TYPE

FURNITURE, FIXTURE, EQUIPMENT

CONTRACT LIMIT LINE

COLUMN CENTER LINE

NEW WALL

DEMOLITION

EXISTING WALL SPOKANE VA MEDICAL CENTER

APPROVED FOR CONSTRUCTION

Project No: 668-21-101

SPOKANE, WA 99205-6197

DESIGN TEAM

ABBREVIATIONS OWNER

CODE REFERENCES

BUILDING CODE:

2021 INTERNATIONAL BUILDING CODE

2018 WASHINGTON STATE BUILDING CODE

2018 WASHINGTON STATE EXISTING BUILDING CODE

2018 WASHINGTON STATE ENERGY CODE

2018 INTERNATIONAL ENERGY CONSERVATION CODE

2018 WASHINGTON STATE FIRE CODE

ACCESSIBILITY CODE & GUIDELINES:

ABAAS & BFDG

MECHANICAL CODE:

2018 INTERNATIONAL MECHANICAL CODE

PLUMBING CODE:

2018 INTERNATIONAL PLUMBING CODE

ELECTRICAL CODE:

2018 INTERNATIONAL ELECTRICAL CODE

PROJECT DESCRIPTION

FACILITY MAP

SYMBOL LEGEND

BUILDING INFORMATION

THIS IS AN EXISTING SINGLE-STORY BUILDING WITH A NEW MECHANICAL

ROOM ADDITION.

GENERAL NOTES

VICINITY MAP

INFECTION CONTROL MEASURES

DEDUCTIVE ALTERNATE #1: REMOVE EXTERIOR WALKWAY COVER

DEDUCTIVE ALTERNATE #2: REMOVE MILLWORK AND COUNTERTOP IN

COPY/WORK ROOM. VA TO PROVIDE FURNITURE.

DEDUCTIVE ALTERNATE #3: PATCH AND REPAIR EXISTING ROOF IN LIEU OF

REPLACING THE ROOF.

DEDUCTIVE ALTERNATE #4: CHECK-IN DESK TO BE VA PROVIDED AND

INSTALLED

DEDUCTIVE ALTERNATE #5: EXISTING BOTTLED EYEWASH TO REMAIN, NO NEW

EYEWASH IN HAC REQUIRED.

DEDUCTIVE ALTERNATE #6: EXISTING FDC AT PARKING ISLAND TO BE

UTILITIZED. NO NEW FDC REQUIRED.

THE SCOPE OF WORK SHALL BE THE RENOVATION OF AN EXISTING SINGLE-STORY

BUILDING AT THE MANN-GRANDSTAFF VA MEDICAL CENTER. THE PRIMARY SCOPE OF

THIS PROJECT IS TO REPLACE THE MECHANICAL AIR HANDLER UNITS AND

PLUMBING. THE SCOPE INCLUDES UPGRADING THE BUILDING TO MEET THE MENTAL

HEALTH DESIGN REQUIREMENTS PROVIDED BY THE VA TIL AND ALL APPLICABLE

CODES. A MECHANICAL ROOM OF 516 SF WILL BE ADDED TO THE BUILDING AND CIVIL

SIDEWALKS WILL BE UPDATED FOR THIS EXPANSION.

THIS WORK SHALL INCLUDE BUT NOT BE LIMITED TO ARCHITECTURAL, STRUCTURAL,

MECHANICAL, PLUMBING, & ELECTRICAL.

ALTERNATES

DESCRIPTIONSYMBOL

RENOVATE BUILDING 7 - MENTAL HEALTH

MANN-GRANDSTAFF VA MEDICAL CENTER

DEPARTMENT OF VETERANS AFFAIRS

Architect

MPE Engineers

1050 E. Southern Ave. Suite 5, Tempe, Arizona 85282

AESUS Design Group

1050 E. Southern Ave. Suite 5, Tempe, Arizona 85282

AESUS Design Group

Orlando Gonzales (ogonzales@aesusdesign.com)

480-454-2861

David Combs (dcombs@aesusdesign.com)

480-454-2861

Structural Engineers

NORTH

Landscape ArchitectBUILDING OCCUPANCY:

GROUP I-2; B, S2 (INCIDENTIAL USES)

CONSTRUCTION TYPE:

EXISTING = TYPE II (ORIGINAL BLDG) AND TYPE V (OFFICE ADDITIONS)

PROPOSED MECHANICAL ROOM ADDITION = TYPE II

-FIRE RESISTANCE IN ACCORDANCE WITH IBC TABLES 601 & 602

-ENTIRE BUILDING TO BE FULLY SPRINKLER THE ENTIRE BUILDING

-NO FIRE SEPARATION REQUIRED

-ENTIRE BUILDING TO RECEIVE FIRE ALARM SYSTEM UTILIZING A TOTAL

EVACUATION STRATEGY.

-ENTIRE BUILDING TO RECEIVE EMERGENCY LIGHTING.

BUILDING AREA:

ACTUAL

EXISTING 7,900 SF

REMODEL 7,900 SF

ADDITION 516 SF

TOTAL 8,416 SF

BUILDING IS WITHIN ALLOWABLE AREA FOR TYPE II AND V (IBC 506.2)

BUILDING HEIGHT:

ACTUAL

HEIGHT 14 FT

STORIES 1

BUILDING IS WITHIN ALLOWABLE AREA FOR TYPE II AND V (IBC 504.3)

OCCUPANCY LOAD FACTORS (NFPA 101 TABLE 7.3.1.2):

ASSEMBLY = 1:15

BUSINESS = 1:150

STORAGE = 1:500

MINIMUM NUMBER OF EXITS (TABLE 1006.3.2)

OCCUPANT LOAD PER STORY MIN EXITS PER STORY

1-500 2

EXIT ACCESS TRAVEL DISTANCE (TABLE 1017.2)

I-2 OCCUPANCY WITH SPRINKLERS = 200 FEET

DEAD END CORRIDORS (IBC 1020.4)

I-2 OCCUPANCY WITH SPRINKLERS = 20 FEET

PROJECT SITE

1050 E. Southern Ave. Suite 5, Tempe, Arizona 85282

AESUS Design Group

NFPA

NFPA 101 LIFE SAFETY CODE

NFPA NATIONAL FIRE CODES

NFPA 900 (OSHA)

David Combs (dcombs@aesusdesign.com)

480-454-2861

MANN-GRANDSTAFF

A. ANY CHANGES MUST BE APPROVED BY CO BEFORE DOING ANY

ADDITIONAL WORK. WORK SCHEDULE TO BE PERFORMED DURING

REGULAR DAY SHIFT HOURS (8AM-4:30PM) ANY WORK OUTSIDE OF

REGULAR SCHEDULE REQUIRES APPROVAL FROM CO.

B. REFER TO PROJECTS LAYDOWN, STAGING, AND IMPACT AREAS FOR

LAYDOWN AND STAGING AREAS - COORDINATE WITH CO.

C. PERFORM WORK IN ACCORDANCE WITH VHA DIRECTIVE 2017-7715

SAFETY AND HEALTH DURING CONSTRUCTION ACTIVITIES AND VHA

DIRECTIVE 7703 OCCUPATIONAL SAFETY MANAGEMENT SYSTEMS IN

VHA, 19HEF.

D. WORK PERFORMED FOR THIS PROJECT MAY INTERRUPT SERVICE TO

ADJACENT AREAS AT TIMES BUT WILL NOT INTERRUPT OVERALL

FACILITY OPERATION. SEE ELECTRICAL FOR POWER INTERRUPTION

AND OUTAGE REQUIREMENTS.

E. CONTRACTOR TO VERIFY ALL DETAILS AGAINST EXISTING

CONDITIONS PRIOR TO PURCHASE OF EQUIPMENT AND PRIOR TO

CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR BRINGING ANY

DISCREPANCIES IN PLANS AND EXISTING SITE CONDITIONS TO

IMMEDIATE ATTENTION OF CONTRACTING OFFICER.

F. CONTRACTOR SHALL PERFORM ALL WORK AND PROVIDE ALL

MATERIALS IN ACCORDANCE WITH VA MASTER CONSTRUCTION

SPECIFICATIONS, WHICH CAN BE FOUND AT

HTTP://WWW.CFM.VA.GOV/TIL/. WHERE DISCREPANCIES ARE FOUND

THE MORE STRINGENT SHALL APPLY.

G. NOT ALL KEYNOTES ARE ON ALL SHEETS.

225 Broadway, Suite 1250, San Diego, CA 92101

Thornton Tomasetti

Ross Cussen (rcussen@thorntontomasetti.com) 619-550-5900

MES Group, Inc.

550 North Reo Street Suite 203 Tampa, FL 33609 D: 813.331.5089 M: 727.510.3597

Civil Engineers Calibre 9090 S Ridgeline Blvd, Suite 105, Highlands Ranch, CO 80129 Blake Gude (bgude@calibre-engineering.com)

303-760-0434

Low Voltage:

PROOF, WORKING POINT

CONTRACTOR

PARKING AREA

CONEX FARM

LAYDOWN

AREA

JOBSITE

TRAILER

and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center

4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS

G.003

ROOM SCHEDULE & SHEET INDEX

ROOM SCHEDULE - LEVEL-01

NUMBER NAME AREA

VA STANDARD

PROGRAM

AREA

B7-050 MECHANICAL ROOM CRAWL SPACE 516 ft² -

B7-051 ENTRANCE 138 ft² 120nsf

B7-100 RECEPTION 87 ft² 120nsf

B7-101 WAITING AREA 359 ft² 160nsf

B7-102 ADA TOILET 73 ft² 60nsf

B7-103 ADA TOILET 72 ft² 60nsf

B7-104 ADA TOILET 62 ft² 60nsf

B7-106 ADA TOILET 62 ft² 60nsf

B7-107 COPY / WORK 102 ft² 120nsf

B7-109 OFFICE 102 ft² 125nsf

B7-111 OFFICE 102 ft² 125nsf

B7-112 GROUP/CONFERENCE ROOM 305 ft² 300nsf

B7-113 TELEHEALTH 223 ft² 125nsf

B7-114 OFFICE 138 ft² 125nsf

B7-117 TELEHEALTH 203 ft² 125nsf

B7-118 OFFICE 111 ft² 125nsf

B7-119 TELEHEALTH 203 ft² 125nsf

B7-120 OFFICE 111 ft² 125nsf

B7-121 TELEHEALTH 222 ft² 125nsf

B7-122 IT CLOSET 137 ft² 120nsf

B7-124 STAFF LOUNGE 162 ft² 80nsf

B7-125 STORAGE 50 ft² 80nsf

B7-126 ELECTRICAL 137 ft² 120nsf

B7-127 ADA TLT 53 ft² 60nsf

B7-128 ADA TLT 53 ft² 60nsf

B7-130 EXISTING OFFICE 107 ft² 125nsf

B7-131 EXISTING OFFICE 105 ft² 125nsf

B7-132 EXISTING OFFICE 104 ft² 125nsf

B7-133 EXISTING OFFICE 104 ft² 125nsf

B7-134 EXISTING OFFICE 105 ft² 125nsf

B7-135 EXISTING OFFICE 105 ft² 125nsf

B7-136 EXISTING OFFICE 105 ft² 125nsf

B7-137 EXISTING OFFICE 103 ft² 125nsf

B7-138 EXISTING OFFICE 103 ft² 125nsf

B7-139 EXISTING OFFICE 100 ft² 125nsf

B7-140 EXISTING OFFICE 107 ft² 125nsf

B7-141 EXISTING OFFICE 148 ft² 125nsf

B7-142 EXISTING OFFICE 128 ft² 125nsf

B7-143 EXISTING OFFICE 111 ft² 125nsf

B7-144 EXISTING OFFICE 147 ft² 125nsf

B7-145 OFFICE 110 ft² 125nsf

B7-147 HOUSE KEEPING 82 ft² -

B7-150 MECHANICAL ROOM 516 ft² -

B7-C1 CORRIDOR 1748 ft² -

7919 ft²

ISSUED SHEETS

- Sheet Name 10

S U

B M

IT

T

A L

S U

B M

IT

T

A L

S U

B M

IT

T

A L

S U

B M

IT

T

A L

0%

S ub m is si on

B id

S et

S ub m is si on

GENERAL

G.001 COVER SHEET ■ ■ ■ ■ ■ ■

G.002 PROJECT INFORMATION ■ ■ ■ ■ ■ ■

G.003 ROOM SCHEDULE & SHEET INDEX ■ ■ ■ ■

CIVIL

CD.100 EXISTING CONDITIONS AND DEMO ■ ■ ■ ■

CS.100 CIVIL SITE PLAN ■ ■ ■ ■

GR100 GRADING ■ ■ ■ ■

GR110 SIDEWALK CROSS-SECTIONS ■ ■

EC100 EROSION AND SEDIMENT CONTROL ■ ■ ■ ■

DT100 CIVIL DETAILS ■ ■ ■ ■

ARCHITECTURAL

A.001 ARCHITECTURAL SITE PLAN ■ ■ ■ ■ ■ ■

AD.101 DEMOLITION FLOOR PLAN ■ ■ ■ ■ ■ ■

ALS.200 ARCHITECTURAL LIFE SAFETY PLAN ■ ■ ■ ■

A.200 UTILITY BASEMENT FLOOR PLAN ■ ■ ■ ■

A.201 PROPOSED FLOOR PLAN ■ ■ ■ ■ ■ ■

A.202 ROOF PLAN ■ ■ ■ ■ ■ ■

A.210 ENLARGED PLANS & ELEVATIONS ■ ■ ■ ■ ■

A.300 PARTITION TYPES ■ ■ ■ ■

A.301 REFLECTED CEILING PLAN ■ ■ ■ ■

A.302 PARTITION HEAD DETAILS ■ ■ ■ ■

A.304 GYP BD DETAILS 01 ■ ■ ■ ■

A.320 ADAAG/ANSI TOILET LAYOUTS AND STD ACCESSORIES ■ ■ ■ ■

A.324 ACCESSORIES, WALL PROT, EQUIP, MOUNTING DETAILS ■ ■ ■ ■

A.331 DOOR, SAFETY GLAZING AND LOUVER INFORMATION ■ ■ ■ ■

A.350 CABINET DETAILS ■ ■ ■ ■ ■

A.401 CEILING DETAILS ■ ■ ■ ■

A.601 EXTERIOR ELEVATIONS AND SECTIONS ■ ■ ■ ■

A.701 EIFS & SITE DETAILS ■ ■ ■ ■

A.751 ROOF DETAILS ■ ■ ■ ■

A.901 INTERIOR FINISH PLAN ■ ■ ■ ■ ■

STRUCTURAL

S-000 COVER SHEET ■

S-001 GENERAL STRUCTURAL NOTES ■

S-002 GENERAL STRUCTURAL NOTES ■

S-003 LEGEND AND ABBREVIATIONS ■

S-004 LAP SPLICES, DEVELOPMENT LENGTH, AND STANDARD HOOKS

SCHEDULES

S-005 SPECIAL INSPECTIONS AND STRUCTURAL TESTING ■

S-006 SPECIAL INSPECTIONS AND STRUCTURAL TESTING ■

S-010 LOADING PLANS ■

S-020 MODEL VIEWS ■

S-100 FRAMING PLANS - MECHANICAL ADDITION ■

S-110 FRAMING PLANS-SEISMIC UPGRADE RETROFITS ■

S-200 TYPICAL FOUNDATION WALL DETAILS ■

S-201 TYPICAL SLAB ON GRADE DETAILS ■

S-300 TYPICAL STEEL BEAM DETAILS ■

S-301 TYPICAL STEEL BEAM PENETRATION DETAILS ■

S-302 TYPICAL ROOF DECK DETAILS ■

S-400 TYPICAL CONCRETE DETAILS ■

S-500 SECTIONS AND DETAILS ■

MECHANICAL

M.001 MECHANICAL GENERAL NOTES, ABBREVIATIONS & SYMBOLS ■ ■ ■ ■ ■

MD.201 MECHANICAL DEMOLITION FLOOR PLAN ■ ■ ■ ■ ■

M.201 MECHANICAL FLOOR PLAN ■ ■ ■ ■ ■

M.202 MECHANICAL ROOF PLAN ■ ■ ■

M.501 MECHANICAL DETAILS ■ ■ ■ ■

M.502 MECHANICAL DETAILS ■ ■ ■ ■

M.601 MECHANICAL SCHEDULES ■ ■ ■ ■ ■

M.801 MECHANICAL CONTROLS ■ ■ ■

M.802 MECHANICAL CONTROLS ■ ■ ■

PLUMBING

P.001 PLUMBING GENERAL NOTES, SYMBOLS & ABBREVIATIONS ■ ■ ■ ■ ■

PD.201 PLUMBING DEMOLITION FLOOR PLAN ■ ■ ■ ■ ■

P.201 PLUMBING FLOOR PLAN ■ ■ ■ ■ ■

P.202 PLUMBING ROOF PLAN ■ ■ ■

P.501 PLUMBING DETAILS ■ ■ ■ ■

ELECTRICAL

E.000 SYMBOLS AND ABBREVIATIONS ■ ■ ■ ■ ■

ES.101 ELECTRICAL SITE PLAN ■ ■ ■ ■

ED.101 ELECTRICAL DEMO POWER PLAN ■ ■ ■ ■ ■

EP.100 ELECTRICAL POWER PLAN - BASEMENT ■ ■ ■ ■ ■

EP.101 ELECTRICAL POWER PLAN - GROUND LEVEL ■ ■ ■ ■ ■

EP.102 ELECTRICAL POWER PLAN - ROOF LEVEL ■ ■ ■ ■ ■

EP.103 ELECTRICAL MECHANICAL POWER PLAN ■ ■ ■ ■ ■

EP.104 LIGHTNING PROTECTION AND GROUNDING PLAN ■ ■ ■ ■

EP.401 ELECTRICAL DETAILS ■ ■ ■

EP.402 ELECTRICAL DETAILS ■ ■ ■

EP.403 LIGHTNING PROTECTION DETAILS ■ ■ ■

EP.405 GROUNDING DETAILS ■ ■ ■

EP.406 TYPICAL MOUNTING HEIGHT DETAILS ■ ■ ■

EP.407 TYPICAL LABELING DETAILS ■ ■ ■

EP.408 TYPICAL LABELING DETAILS ■ ■ ■

EP.501 ELECTRICAL MECHANICAL SCHEDULES ■ ■ ■ ■ ■

EP.601 ELECTRICAL ONE-LINE DIAGRAM ■ ■ ■ ■

EP.701 ELECTRICAL PANEL SCHEDULES ■ ■ ■ ■

EL.100 ELECTRICAL LIGHTING PLAN - BASEMENT ■ ■ ■ ■ ■

EL.101 ELECTRICAL LIGHTING PLAN - GROUND LEVEL ■ ■ ■ ■ ■

EL.102 PHOTOMETRIC ■ ■ ■

EL.400 LIGHTING DETAILS ■ ■ ■

SPECIAL SYSTEMS

EY.000 ELECTRICAL SYSTEMS GENERAL SHEET ■ ■ ■

EY.201 ELECTRICAL SYSTEMS NEW FLOOR PLAN ■ ■ ■

EY.300 LOW VOLTAGE SYSTEMS DETAILS ■ ■ ■

FIRE PROTECTION

FD.101 PROPOSED FIRST FLOOR FIRE PROTECTION DE ■ ■ ■

FX.001 LEGEND, NOTES, DETAILS - FIRE PROTECTION ■ ■ ■

FX.002 FIRE PROTECTION CALCULATIONS ■ ■ ■

FX.101 PROPOSED FIRST FLOOR FIRE PROTECTION PLAN ■ ■ ■

FX.201 PROPOSED FIRE FLOOR FIRE PROTECTION ROOM CLASSIFICATIONS ■ ■ ■

FX.901 SPRINKLER ISOMETRIC ■ ■ ■

FD.101 PROPOSED FIRST FLOOR FIRE PROTECTION DEMO PLAN

FX.001 LEGEND, NOTES, DETAILS - FIRE PROTECTION

FX.002 FIRE PROTECTION CALCULATIONS

BLDG 7

BLDG 15

IN

D

E P

E N

D E

N C

E W

A Y

FREEDOM WAY

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center 4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS 6

35754

JA

MES A LA N GUSKYCO

LO

RADO REG I STERED

PROFESS IONA L ENGIN

EE

R

04-05-2023

EXISTING CONDITIONS &

DEMOLITION

CD100

# KEY NOTES:

LEGEND:

SHEET NOTES:

IN

D

E P

E N

D E

N C

E W

A Y

FREEDOM WAY

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center 4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS 6

35754

JA

MES A LA N GUSKYCO

LO

RADO REG I STERED

PROFESS IONA L ENGIN

EE

R

04-05-2023

CS100

CIVIL SITE PLAN

# KEY NOTES:

IN

D

E P

E N

D E

N C

E W

A Y

FREEDOM WAY

EX.1904.4

EX.1905.2

EX.1904.3

EX.1905.5

EX.1903.7

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center 4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS 6

35754

JA

MES A LA N GUSKYCO

LO

RADO REG I STERED

PROFESS IONA L ENGIN

EE

R

04-05-2023

GRADING SHEET

GR100

# KEY NOTES:

FREEDOM WAY

0+20 0+25 0+30

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center 4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS 6

35754

JA

MES A LA N GUSKYCO

LO

RADO REG I STERED

PROFESS IONA L ENGIN

EE

R

04-05-2023

SIDEWALK CROSS-SECTIONS

GR110

SECTIONS

IN

D

E P

E N

D E

N C

E W

A Y

FREEDOM WAY

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center 4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS 6

35754

JA

MES A LA N GUSKYCO

LO

RADO REG I STERED

PROFESS IONA L ENGIN

EE

R

04-05-2023

STORM WATER CONTROL

EC100

LEGEND:

# KEY NOTES:

and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center 4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS 6

CIVIL DETAILS

DT100

1.4' X 2.3' CONCRETE DUCT BANK

3" MONOLITHIC CURB

N.T.S

35754

JA

MES A LA N GUSKYCO

LO

RADO REG I STERED

PROFESS IONA L ENGIN

EE

R

04-05-2023

A.601/ 1

A .6

EXISTING

BUILDING 27 BUILDING 7

MENTAL HEALTH BUILDING

(NOT IN CONTRACT)

IN

D

E P

E N

D E

N C

E D

R

IV

E

NEW SIDEWALK

NEW MECHANICAL

BUILDING

(516 ft2) C O

V E

R E

D

W

L K

W A

Y

25' - 0"

MRI ADDITION

(NOT IN CONTRACT)

FUTURE BUILDING

(AREA OF RENOVATION = 7,462 ft2)

CONCRETE BARRIERS TO BE

PROVIDED BY CONTRACTOR AT

25 FT FROM FACE OF BUILDING

7 TO PREVENT VEHICULAR

TRAFFIC ACCESS

PSRDM SETBACK

REQUIREMENT

PROPOSED NEW

CRAWLSPACE ACCESS

EXISTING

CRAWLSPACE

ACCESS

PSRDM SETBACK

P S

R D

M S

E T

B A

C K

PSRDM SETBACK

P S

R D

M S

E T

B A

C K

Q U

IR

E

M E

N T

FUTURE ADDITION

EXISTING

LANDSCAPE TO

REMAIN

EXISTING

LANDSCAPE TO

REMAIN

EXISTING

LANDSCAPE TO

REMAIN

N

W

S

ID

E W

A L

K

EXISTING

SIDEWALK

EXISTING

SIDEWALK

EXISTING

SIDEWALK

EXISTING

TO REMAIN

EXISTING

TO REMAIN

EXISTING

TO REMAIN

EXISTING

TO REMAIN

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center

4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS

A.001

ARCHITECTURAL SITE PLAN

1" = 10'-0"01 ARCHITECTURAL SITE PLAN

(E L) "7E

(E L) "7C

(E ) "7A

(E ) "7E

B

WORK

WAIT

HALL

FEMALE TLT

STOR

MALE TLT

GROUP

OFFICE

STOR

TLT

OFFICE OFFICE GROUP OFFICE OFFICE OFFICE

GROUP OFFICE OFFICE OFFICE

TLT

STOR

HALL HALL

OFFICE

NOURISHH

A

LL

HALL

M E

C H

OFFICEOFFICEOFFICEOFFICE

O

FFIC

EOFFICEOFFICEOFFICE

HALL

HALL

HSKP

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICEOFFICEOFFICE

HALL

FEMALE TLT

101A

101B

103A

109 111 115 117 119 121

112 114 118 120

1371361351341

132131130

140139138

B

C

32.521 1.5

2 2

2 2

222222222222

2 2 2 4

5 5 5 5 5 5 5 5 5 5 56 6

6 6 6 6 6 6 6 6 6 6

7 7 7 7

7777777777

8 8 8 8 8

8 9

9 9 9 9

1 1 1

6 6

6 6 6

7 7

9 9 9 9 9

DEMOLITION SYMBOL LEGEND

KEYED DEMOLITION NOTES

ITEMS SHOWN DASHED TO BE

DEMOLISHED

HATCH INDICATES AREA TO BE COVERED

BY KEYED NOTES LOCATED WITHIN

01 02

GENERAL DEMOLITION NOTES

A. EXISTING CONSTRUCTION TO BE REMOVED IS INDICATED ON THE

DRAWINGS: COORDINATE DEMOLITION WITH ARCHITECTURAL DRAWINGS

AND REQUIREMENTS SHOWN ON ALL MECHANICAL PLUMBING AND

ELECTRICAL, AND STRUCTURAL DRAWINGS

B. EXISTING CONDITIONS SHOWN ARE FROM AVAILBLE RECORD DRAWINGS

AND VISUAL FIELD SURVEYS. THE CONTRACTOR SHALL VERIFY ACTUAL

EXISTING CONDITIONS AND NOTIFY THE OWNER OF ANY DISCREPENCIES.

C. CONDUCT DEMOLITION TO MINIMIZE INTERFERENCE WITH ADJACENT

BUILDING AREAS

D. AREA OF WORK CONTAINS BUILDING INFRASTRUCTURE WHICH MAY BE

CRITICAL TO THE ONGOING OPERATIONS OF THE HOSPITAL. ATTENTION

SHALL BE BROUGHT TO THE COR PRIOR TO ANY DEMOLITION OR SHUT-

DOWNS. REFER TO SPECIFICATIONS FOR MAJOR AND MINOR SHUTDOWN

PROCEDURES.

E. PROTECT EXISTING MATIERALS AND EQUIPMENT WHICH ARE NOT TO BE

DEMOLISHED. CONTRACTOR TO PROTECT FROM DAMAGE ALL EXISTING

FLOORS, WALLS, CEILINGS, ETC. CONTRACTOR IS RESPONSIBLE FOR

REPAIR AND REPLACEMENT OF ALL DAMAGED FLOORING, WALLS,

CEILINGS, ETC. IF AREAS NEED TO BE REPAIRED, FINISHES ARE TO MATCH

EXISTING. CONTRACTOR TO DOCUMENT EXISTING CONDITIONS WITHIN ALL

DEMOLITION/CONSTRUCTION AREAS. PHOTOGRAPHIC DOCUMENTATION

TO BE PROVIDED TO COR BEFORE ANY DEMOLITION/CONSTRUCTION

COMMENCES.

F. MAINTAIN PROTECTED EGRESS AND ACCESS TO THE WORK. ALSO

MAINTAIN REQUIRED EGRESS AROUND TEMPORARY PARTITIONS.

G. REMOVE ANY UNUSED OR ABANDONED MATERIALS IN WALLS AND ABOVE

CEILINGS.

H. THE CONTRACTOR SHALL NOTIFY THE OWNER IN ADVANCE OF ANY

SCHEDULED DEMO WORK IN THE AREA TO ALLOW THE OWNER TO REMOVE

PERSONAL BELONGINGS AND DESIGNATE ALL MEDICAL EQUIPMENT,

FURNITURE, AND OTHER ITEMS TO BE SALVAGED AND STORED BY THE

CONTRACTOR. ALL ITEMS NOT DESIGNATED AS "SALVAGED" BY THE

OWNER AFTER THIS TIME SHALL BE DISPOSED OF BY THE CONTRACTOR.

REFER TO SPECIFICATION FOR NOTIFICATION REQUIREMENTS.

I. OWNER SHALL REMOVE ALL EQUIPMENT AND WALL-MOUNTED FURNITURE,

AND ALL WALL MOUNTED SINGAGE AND ARTWORK TO BE SALVAGED PRIOR

TO COMMENCEMENT OF DEMOLITION.

J. SCOPE OF WORK TO BE REMOVED IS SHOWN WITH DASHED LINES.

COORDINATE EXTENT OF DEMOLITION OF EXISTING ITEMS TO BE

PARTIALLY DEMOLISHED WITH THE FLOOR PLAN AND REFLECTED CEILING

PLAN.

K. REMOVE AND SALVAGE ANY DOORS, DOOR CLOSERS, AND MAGNETS,

PNEUMATIC DAMPER OPERATORS, AND HEATING COIL ACTUATORS AND

VLAVES. SALVAGED ITEMS ARE TO BE STORED BY CONTRACTOR IF THEY

ARE TO BE RE-USED IN PROJECT.

L. CONTRACTOR SHALL REMOVE EXISTING INSULATION OR PIPE JACKETING

WHERE IT DOES NOT COMPLY WITH FIRE STOPPING REQUIREMENTS AT

PIPING PENETRATIONS AND OTHER CONDITIONS WHERE FIRE STOPPING IS

REQUIRED. REFER TO, AND COMPLY WITH, I.B.C. SECTION 712.

M. REMOVE ANY REMAINING CASEWORK AND EQUIPMENT NOT INDICATED ON

PLANS IN SPACES, REQUIRING DEMOLITION IN ITS ENTIRETY.

N. REMOVE AND DISPOSE OF ALL DEMOLISHED MATERIALS OFF-SITE WHICH

ARE NOT SCHEDULED TO REMAIN, BE RELOCATED, OR BECOME THE

PROPERTY OF THE OWNER.

O. DO NOT PROCEED WITH DEMOLITION WORK BEFORE THE INSTALLATION OF

CONSTRUCTION TUNNEL AND BARRICADES. RELOCATE CONSTRUCTION

BARRICADES AS NECESSARY FOR CONSTRUCTION WORK AND/OR AS

DIRECTED BY VA AT NO ADDITIONAL COST TO VA.

P. CONTRACTOR TO SUBMIT BARRICADE LOCATIONS DRAWINGS TO VA FOR

REVIEW AND APPROVAL PRIOR TO THE INSTALLATION.

Q. PROVIDE CONSTRUCTION BARRICADE IN ALL OCCUPIED AREAS AS

REQUIRED AND/OR AS DIRECTED BY VA AT NO ADDITIONAL COST TO VA.

R. PROVIDE TEMPORARY EXIT SIGNS AND ILLUMINATION LEVELS PER THE IBC

AND VA GUIDELINES. ALL EGRESS PATHS SHALL REMAIN CLEAR AT ALL

TIMES.

S. ALL CONSTRUCTION BARRICADES FIRE-RATING SHALL MAINTAIN FIRE

RATING CONTINUITY OF THE SURROUNDING WALLS. FIRE-RATING OF

CONSTRUCTION ACCESS DOORS SHALL BE APPROPRIATE FOR THE FIRE-

RATED WALL TYPES. PAINT ALL TUNNELS AND BARRICADES ON THE SIDE

VISIBLE TO THE PUBLIC.

T. CONTRACTOR TO VERIFY EXISTING CONDITIONS AT ALL COLUMNS AND

CHASES PRIOR TO DEMOLITION

U. REMOVE CONSTRUCTION TUNNEL AND BARRICADE AT COMPLETION OF

EACH PHASE AND EACH PROJECT'S CONSTRUCTION WORK, U.O.N.

V. DO NOT PENETRATE THE FLOOR SLAB WITHOUT COORDINATING WITH

STRUCTURAL REQUIREMENTS.

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center

4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS

AD.101

DEMOLITION FLOOR PLAN

1/8" = 1'-0"1 LEVEL 01_DEMOLITION

DEMOLITION KEYNOTE LEGEND

KEY

VALUE KEYNOTE TEXT

1 DEMOLISH EXISTING WALL

2 REMOVE DOOR

3 REMOVE PLUMBING FIXTURES & ACCESSORIES

4 EXISTING DOOR TO REMAIN. REPLACE HARDWARE PER SCHEDULE.

5 REMOVE EXISTING GYP BD, POWER, AND DATA. EXISTING STUDS TO

REMAIN

6 REMOVE EXISTING CEILING AND ALL CEILING MOUNTED

ACCESSORIES OR FIXTURES

7 REMOVE EXISTING FINISHES

8 REMOVE EXISTING WINDOWS AND REPLACE WITH NEW ENERGY

EFFICIENT WINDOWS IN PLACE

9 REMOVE EXISTING WINDOW. INFILL EXTERIOR WALL AND PATCH

FINISHES AS REQUIRED

B

C C

32.521 1.50 0.5

BC

72 ft²

ADA TOILET

B7-103

102 ft²

COPY /

WORK

B7-107

102 ft²

OFFICE

B7-109

359 ft²

WAITING

AREA

B7-101

223 ft²

TELEHEALTH

B7-113

305 ft²

GROUP/CONFERENCE

ROOM

B7-112

203 ft²

TELEHEALTH

B7-117

203 ft²

TELEHEALTH

B7-119

222 ft²

TELEHEALTH

B7-121

138 ft²

OFFICE

B7-114

162 ft²

STAFF

LOUNGE

B7-124

53 ft²

ADA TLT

B7-127

53 ft²

ADA TLT

B7-128

50 ft²

STORAGE

B7-125

137 ft²

IT CLOSET

B7-122

110 ft²

OFFICE

B7-145

147 ft²

EXISTING

OFFICE

B7-144

111 ft²

EXISTING

OFFICE

B7-143

128 ft²

EXISTING

OFFICE

B7-142

148 ft²

EXISTING

OFFICE

B7-141107 ft²

EXISTING

OFFICE

B7-140

100 ft²

EXISTING

OFFICE

B7-139

103 ft²

EXISTING

OFFICE

B7-138

103 ft²

EXISTING

OFFICE

B7-137

105 ft²

EXISTING

OFFICE

B7-136 105 ft²

EXISTING

OFFICE

B7-135

105 ft²

EXISTING

OFFICE

B7-134

104 ft²

EXISTING

OFFICE

B7-133104 ft²

EXISTING

OFFICE

B7-132

105 ft²

EXISTING

OFFICE

B7-131

107 ft²

EXISTING

OFFICE

B7-130

82 ft²

HOUSE

KEEPING

B7-147

137 ft²

ELECTRICAL

B7-126

516 ft²

MECHANICAL

ROOM

B7-150

C L R

111 ft²

OFFICE

B7-118

73 ft²

ADA TOILET

B7-102

102 ft²

OFFICE

B7-111

111 ft²

OFFICE

B7-12062 ft²

ADA TOILET

B7-104

62 ft²

ADA TOILET

B7-106

1748 ft²

CORRIDOR

B7-C1

F.F. = 1905.66

F.F. = 1905.66

8' - 7"

138 ft²

ENTRANCE

B7-051

87 ft²

RECEPTION

B7-100

TRAVEL DISTANCE

40' - 5"

TRAVEL DISTANCE

72'-0"

TRAVEL DISTANCE

128'-4"

FEC FEC

FEC

FEC

FEC

6' - 0"

6' - 0"

6' - 0"

2' - 8"

TRAVEL DISTANCE

124'-0"

REFER TO A.201 FOR

ADDITIONAL INFORMATION

AT IT CLOSET

FEC

LIFE SAFETY PLAN OCCUPANCY LOAD CALCULATIONS

BUSINESS: 1 OCCUPANT PER 150 SF

3,850 SF / 150 = 26 OCCUPANTS

STORAGE: 1 OCCUPANT PER 500 SF

920 SF / 500 = 2 OCCUPANTS

ASSEMBLY: 1 OCCUPANT PER 15 SF

1042 SF / 15 = 70 OCCUPANTS

TOTAL OCCUPANTS = 98

EXIT REQUIREMENTS

MINIMUM EXIT WIDTH = 32" (PER IBC 1010.1.1)

MINIMUM PROVIDED EXIT WIDTH = 32"

GENERAL LIFE SAFETY PLAN NOTES

BUILDING OCCUPANCY:

GROUP I-2; B, S2 (INCIDENTIAL USES)

CONSTRUCTION TYPE:

EXISTING = TYPE II (ORIGINAL BLDG) AND TYPE V (OFFICE ADDITIONS)

PROPOSED MECHANICAL ROOM ADDITION = TYPE II

- FIRE RESISTANCE IN ACCORDANCE WITH IBC TABLES 601 & 602.

- ENTIRE BUILDING TO BE FULLY SPRINKLERED.

- NO FIRE SEPARATION REQUIRED.

- ENTIRE BUILDING TO RECEIVE FIRE ALARM SYSTEM UTILIZING A

TOTAL EVACUATION STRATEGY.

- ENTIRE BUILDING TO RECEIVE EMERGENCY LIGHTING.

- EXISTING EXITS TO REMAIN.

- EXISTING TRAVEL DISTANCES TO REMAIN.

- ALL CORRIDORS UPGRADED TO 6'-0" CLEAR WIDTH.

BUILDING AREA:

ACTUAL

EXISTING 7,900 SF

REMODEL 7,900 SF

ADDITION 516 SF

TOTAL 8,416 SF

BUILDING IS WITHIN ALLOWABLE AREA FOR TYPE II AND V (IBC 506.2)

BUILDING HEIGHT:

ACTUAL

HEIGHT 14 FT

STORIES 1

BUILDING IS WITHIN ALLOWABLE AREA FOR TYPE II AND V (IBC 504.3)

OCCUPANCY LOAD FACTORS (NFPA 101 TABLE 7.3.1.2):

ASSEMBLY = 1:15

BUSINESS = 1:150

STORAGE = 1:500

MINIMUM NUMBER OF EXITS (TABLE 1006.3.2)

OCCUPANT LOAD PER STORY MIN EXITS PER STORY

1-500 2

EXIT ACCESS TRAVEL DISTANCE (TABLE 1017.2)

I-2 OCCUPANCY WITH SPRINKLERS = 200 FEET

DEAD END CORRIDORS (IBC 1020.4)

I-2 OCCUPANCY WITH SPRINKLERS = 20 FEET

LIFE SAFETY PLAN LEGEND

EXIT SYMBOL

EXIT SIGN -

HATCH INDICATES EXIT

TEXT AND ARROW

INDICATES DIRECTION

NON RATED WALL

FIRE EXTINGUISHER CABINET

FIRE EXTINGUISHER ON HOOK

TRAVEL DISTANCE FROM

THE MOST REMOTE POINT

TO THE CLOSEST EXIT

XXX'-X"

FEC

FE

EXIT CORRIDOR

STORAGE

BUSINESS

ASSEMBLY

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center

4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS

ALS.200

ARCHITECTURAL LIFE SAFETY PLAN

3/16" = 1'-0"1 LEVEL 01_LIFE SAFETY PLAN

B

C C

32.521 1.50 0.5

BC

MECHANICAL

ROOM

CRAWL

SPACE

B7-050

EXISTING CRAWL

SPACE TO REMAIN

PROVIDE NEW CRAWL

SPACE ACCESS AT

EXISTING MECHANICAL

OPENING. FIELD VERIFY.

REFER TO STRUCTURAL

DRAWINGS FOR CONCRETE

RETAINING WALL DETAILS

EXISTING CRAWL SPACE

ACCESS TO REMAIN

A.601

28' - 6" 8' - 0" 41' - 0" 40' - 5" 15' - 8" 27' - 1"

NEW OPENING,

REFER TO

STRUCTURAL

NEW OPENING,

REFER TO

STRUCTURAL

NEW OPENING,

REFER TO

STRUCTURAL

NEW OPENING,

REFER TO

STRUCTURAL

" 2

/8

EXISTING

OPENING TO

REMAIN

EXISTING

OPENING TO

REMAIN

EXISTING

OPENING TO

REMAIN

INFILL EXISTING

OPENINGS, PAINT TO

MATCH EXISTING

ADJACENT WALL

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center

4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS

A.200

UTILITY BASEMENT FLOOR PLAN

3/16" = 1'-0"1 LEVEL 00 - CRAWL SPACE

N O

R T

H

.6

B

C C

32.521 1.5

72 ft²

ADA TOILET

B7-103

102 ft²

COPY /

WORK

B7-107

102 ft²

OFFICE

B7-109

359 ft²

WAITING

AREA

B7-101

223 ft²

TELEHEALTH

B7-113

305 ft²

GROUP/CONFERENCE

ROOM

B7-112

203 ft²

TELEHEALTH

B7-117

203 ft²

TELEHEALTH

B7-119

222 ft²

TELEHEALTH

B7-121

138 ft²

OFFICE

B7-114

162 ft²

STAFF

LOUNGE

B7-124

53 ft²

ADA TLT

B7-127

53 ft²

ADA TLT

B7-128

50 ft²

STORAGE

B7-125

137 ft²

IT CLOSET

B7-122

110 ft²

OFFICE

B7-145

147 ft²

EXISTING

OFFICE

B7-144

111 ft²

EXISTING

OFFICE

B7-143

128 ft²

EXISTING

OFFICE

B7-142

148 ft²

EXISTING

OFFICE

B7-141107 ft²

EXISTING

OFFICE

B7-140

100 ft²

EXISTING

OFFICE

B7-139

103 ft²

EXISTING

OFFICE

B7-138

103 ft²

EXISTING

OFFICE

B7-137

105 ft²

EXISTING

OFFICE

B7-136 105 ft²

EXISTING

OFFICE

B7-135

105 ft²

EXISTING

OFFICE

B7-134

104 ft²

EXISTING

OFFICE

B7-133104 ft²

EXISTING

OFFICE

B7-132

105 ft²

EXISTING

OFFICE

B7-131

107 ft²

EXISTING

OFFICE

B7-130

82 ft²

HOUSE

KEEPING

B7-147

137 ft²

ELECTRICAL

B7-126

516 ft²

MECHANICAL

ROOM

B7-150

C L R

111 ft²

OFFICE

B7-118

0 0.5

BC

EXISTING TO

REMAIN

A

A3

A

A3

A

A3

A

A3

A3

A

A3

A

A3

A3A 3A3 A3

4 4 4 4 4 4 4 4 4 4 4

73 ft²

ADA TOILET

B7-102

C H

E C

K I

N

S K

A

A

A

A 3A

/A.210 01

A

A3

B

-1

102 ft²

OFFICE

B7-111

111 ft²

OFFICE

B7-120

62 ft²

ADA TOILET

B7-104

62 ft²

ADA TOILET

B7-106

B

-1

B

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

A

A

R

B7-C1

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

B

-1

B7-127

B7-128

B

-1

B

-1

B

-1

B7-107A

B7-101 ø 5' - 6"

E3 A

H3

A

H3

6 6 6 6 6 6

4 4

/A.210 10/A.210 04

B

-1

B

-1

B

-1

B

-1

T2 T2

T1

T1B

-1

B

-1

B

-1

B

-1

A3

A3

T3

1748 ft²

CORRIDOR

B7-C1

B

-1

2BOTTLE

FILLER

T3

F.F. = 1905.66

F.F. = 1905.66

PBCR

PB

HS HS

HSHS

PB

HS

HS

HS

HS

HSHS

HSHS

PBCR

CR

CR

CR

CR

A.601

8' - 7"

B

-0

B7-003

VA TO PROVIDE AND

INSTALL ALL WINDOW

COVERINGS, TYPICAL

B7-150

7' - 7 1/4" 7' - 7 1/4" 9' - 4 7/8" 20' - 0 3/4" 2' - 4 7/8" 8' - 0" 2' - 4 7/8" 2' - 0" 6' - 4 7/8" 2' - 0" 2' - 6 1/2" 9' - 6 7/8" 2' - 9 1/2" 2' - 5 1/2" 14' - 7" 7' - 11 1/2" 6' - 0"

/8

/4

/8

/4

2' - 0" 6' - 4 7/8"

2' - 0"

6' - 4 7/8" 2' - 0" 6' - 4 7/8" 2' - 0" 15' - 10 7/8" 2' - 0" 14' - 4 7/8" 2' - 0" 14' - 4 7/8" 2' - 0" 19' - 1 3/4"

CLR

6' - 0" 8' - 1 1/2"

1' - 9"

3' - 3" 11' - 10 1/2"

/8

/8

C L R

7' - 7 1/2" 4' - 5" 15' - 3" 4' - 5" 15' - 5" 4' - 5" 15' - 4" 4' - 5" 15' - 8 5/8" 4' - 5" 15' - 0 1/4" 4' - 5"

H

CLR

6' - 0"

C L R ø ø 5' - 6"A

A

8 8 8 8 88

CR

6' - 5" 7' - 10 3/8"

A

9 9 9 9 9 9 9 9 9 9

9 9

CR CR

28' - 6" 8' - 0" 41' - 0 1/8" 40' - 4 3/4" 15' - 7 5/8" 27' - 0 7/8"

CLR

6' - 0"

A3

A3 A3 A3

A3

/4

A3A3A3A3 A3A3

A3A3

B7-142

B7-143

B7-144

A3A3 6"

M

88 8

A3 A3 A3 A3

A

A.701

A.701

A.701

/A.701 08

/A.210 13

5 5

2 2

222222222222

1 1 1 1 1

4 1/2" 8' - 10 5/8"

/A.701 07

9' - 0" 10' - 6" 9' - 0"

/A.701 07 /A.701 07

/A.701 07

A.701

FLOOR PLAN GENERAL NOTES

A. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE. LARGER SCALE

DRAWINGS SHALL HAVE PRECEDENCE OVER SMALLER SCALE

DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE OWNER OF ANY

DISCREPENCIES OR CONFLICTS BEFORE PROCEEDING WITH THAT

PORTION OF THE WORK.

B. ALL DIMENSIONS ARE TAKEN FROM EXISTING FACE OF WALLS

C. PRIOR TO START OF ANY WORK, THE CONTRACTOR IS REQUIRED

TO VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE

EXTENT AND NATURE OF WORK TO BE PERFORMED. EXISTING

CONDITIONS MAY SLIGHTLY VARY FROM THOSE SHOWN ON THE

DRAWINGS. THE CONTRACTOR SHALL VERIFY EXISTING

CONDITIONS, DIMENSIONS, AND MATERIALS IN THE FIELD AND

GENERATE A LIST OF DISCREPANCIES IN WRITING AND REPORT

TO THE OWNER. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

D. THE CONTRACTOR SHALL COORDINATE EQUIPMENT AND

MATERIAL TRAFFIC AND STORAGE WITH THE OWNER.

E. ALL ASPECTS OF CONTRACTOR STAGING AND CONSTRUCTION

PHASING SHALL BE APPROVED BY THE OWNER.

F. ALL UTILITY WORK SHALL BE COORDINATED WITH MECHANICAL,

PLUMBING, ELECTRICAL, AND FIRE PROTECTION.

G. REFER AND ADHERE TO THE INFECTION PREVENTION MEASURE

REQUIREMENTS IN SPECIFICATION SECTION 01 35 26 17.

H. EXTEND BOTH SIDES OF GYPSUM BOARD AT PARTITIONS TO

UNDERSIDE OF STRUCTURE IN AREAS WITHOUT CEILING AND

SEAL AIR TIGHT, TYPICAL, U.O.N.

I. PROVIDE HIGH IMPACT GYPSUM WALLBOARD UP TO 4'-0" A.F.F. AT

THE FOLLOWING LOCATIONS:

CORRIDORS, EQUIPMENT STORAGE ROOMS, AND STORAGE

ALCOVES

J. PROVIDE INSULATION FOR ALL INTERIOR SOUND RATED

PARTITIONS, U.O.N. EXTEND INSULATION AND GYPSUM BOARD ON

BOTH SIDES TO UNDERSIDE OF STRUCTURE. NOTCH PARTITION

TIGHTLY AROUND FRAMING AND OTHER CEILING OBSTRUCTIONS,

AND SEAL AIR TIGHT, TYPICAL, U.O.N.

K. PROVIDE CONTINUOUS FIRE RATED CONSTRUCTION AROUND ALL

RECESSED FIXTURES AND ACCESSORIES LOCATED IN FIRE RATED

PARTITIONS

L. PROVIDE AND COORDINATE BACKING PLATES FOR ALL

EQUIPMENT, ACCESSORIES, CASEWORK, ETC.

M. WHERE FLOOR FINISHES CHANGE BETWEEN TWO ROOMS,

TRANSITION SHALL OCCUR AT CENTER OF DOOR, U.O.N.

N. ADJUST FURRING SPACE AS NECESSARY TO CLEAR ANY PIPES OR

CONDUITS WITHIN THE FURRED SPACE. PROVIDE 1/2-INCH

MINIMUM CLEARANCE BETWEEN PIPES/CONDUITS AND THE BACK

OF GYPSUM BOARD, U.O.N.

O. PROVIDE ADDITIONAL FULL HEIGHT 16 GA. STEEL STUDS FROM

FLOOR TO STRUCTURE ABOVE AT EACH ADJUSTABLE SHELF

STANDARD LOCATION.

P. PROVIDE TWO ROWS OF CONTINUOUS BACKING PLATES ALONG

ALL PARTITIONS INSIDE STORAGE ROOMS, U.O.N. VERIFY

MOUNTING HEIGHT OF THE BACKING PLATES WITH OWNER, U.O.N.

Q. WHERE (N) WORK IS INSTALLED IN (E) PARTITIONS, REPLACE (E)

STUDS AS NECESSARY FOR PROPER SUPPORT OF GYP BD.

ASSEMBLY AND WALL MOUNTED EQUIPMENT, EITHER RECESSED

OR SURFACE MOUNTED.

R. PATCH ALL AREAS OF FIREPROOFING WHERE REMOVED FOR

INSTALLATION OF NEW WORK.

S. REMOVE (E) GYP. BD. AS NECESSARY TO INSTALL ALL DUCT,

PIPING, CONDUIT AND ACCESSORIES. REINSTALL GYP. BD. FINISH

TO MATCH EXIST. CONDITIONS AND TO VA'S ACCEPTANCE.

T. REPLACE CORRIDOR CEILING AND FLOORING FINISHES AND PAINT

AFTER REMOVAL OF CONSTRUCTION BARRICADES.

U. PROVIDE FIRESTOPPING AND/OR SEALANT AT ALL UNPROTECTED

PENETRATIONS AND OPENINGS IN EXISTING RATED PARTITIONS

AND FLOOR SLABS EXPOSED DURING THE CONSTRUCTION

PROJECT THAT ARE WITHIN THE PROJECT AREA.

V. CONFIRM THAT ALL EXISTING WIFI IS REMOVED AND SALVAGED

AND RELOCATED IN PLACE. CONTRACTOR TO COORDINATE WITH

OWNER.

W. THE CONTRACTOR SHALL COORDINATE ALL ROOF TOP WORK

WITH THE OWNER AND EXISTING WARRANTY INFORMATION.

X. PRIOR TO SAW CUTTING AND OR CORE DRILLING CONCRETE, THE

CONTRACTOR SHALL V-RAY USING "A MODERN DETECTION

SYSTEM" TO LOCATE REINFORCING AND OBSTRUCTIONS IN THE

CONCRETE.

Y. IF ASBESTOS CONTAINING MATERIALS ARE SUSPECTED, STOP ALL

WORK IN THE AREA AND REPORT TO OWNER.

Z. PROTECT ALL EXISTING CONDITIONS & EQUIPMENT DURING

CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR

PROTECTING ANY OPENINGS AND REPONSIBLE FOR ANY DAMAGE

THAT MAY RESULT FROM SUCH OPENINGS BEING LEFT

UNPROTECTED OR THOSE THAT HAVE OCCURED AS A RESULT OF

PROTECTING THE OPENINGS.

AA. ALL DOORS TO BE LOCATED 6" FROM NEAREST WALL UNLESS

NOTED OTHERWISE.

AB. ALL EQUIPMENT AND FURNITURE SHOWN AS DASHED LINES ARE

VA PROVIDED AND VA INSTALLED. U.O.N.

POWER/DATA SYMBOL LEGEND

PLAN ELEVATION DESCRIPTION

QUAD ELECTRICAL, E4N

DUPLEX ELECTRICAL (EMERGENCY), E2E

CODE BLUE, CB

DATA PORT, D1

OUTLET HEIGHT 18"

DUPLEX ELECTRICAL, E2N

CR CARD READER, ELECTRONIC

PB

PUSH BUTTON AUTO DOOR OPERATOR,

ELECTRONIC

HS HAND SENSOR AUTO DOOR OPERATOR,

ELECTRONIC

DUPLEX ELECTRICAL, GFCI

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM

08-6231

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

Dwg. of

668-21-101

Spokane VA Medical Center

4815 Assembly ST Spokane, WA 99205-6197

AESUS

B7

B7

B1

AESUS

A.201

PROPOSED FLOOR PLAN

3/16" = 1'-0"01 LEVEL 01_PROPOSED FLOOR PLAN

FLOOR PLAN KEYNOTE LEGEND

KEY VALUE KEYNOTE TEXT

1 VA PROVIDED FURNITURE

2 EXISTING DOOR TO REMAIN. REPLACE HARDWARE PER

SCHEDULE.

3 NEW WALL

4 ADD ANTI-SHATTER FILM TO EXISTING WINDOWS TO

REMAIN, TYPICAL

5 POWER AND DATA FOR KIOSK VA TO SEND SPECIFICATIONS

6 REPLACE WINDOW IN PLACE PER WINDOW SCHEDULE.

PATCH AND REPAIR STUCCO AND REPAINT AS REQUIRED

TO MATCH EXISTING EXTERIOR WALL

7 ACCESS HATCH FOR BASEMENT

8 INFILL AND MATCH EXISTING

9 EXISTING STUDS TO REMAIN. NEW PAINTED GYPSUM

BOARD UP TO BOTTOM OF STRUCTURE, WITH SOUND

INSULATION AND ACOUSTICAL SEALANT TO MATCH WALL

TYPE A3

10 VA TO PROVIDE AND INSTALL WINDOW COVERINGS,

TYPICAL

11 IT CLOSET TO HAVE 4'X 8' AC GRADE 3/4" TRADE SIZE

PLYWOOD BACKBOARD PAINTED HIGH-GLOSS WHITE WITH

TWO COATS OF FIRE RESISTANT PAINT

.6

B

C C

32.521 1.5

REMOVE EXISTING ROOF AND

ROOF MOUNTED EQUIPMENT.

REPLACE WITH INSULATION AND

TPO ROOF MEMBRANE

NEW TPO ROOF

0 0.5

BC

28' - 6" 8' - 0" 41' - 0" 40' - 5" 15' - 8" 27' - 1"

REMOVE EXISTING ROOF AND

ROOF MOUNTED EQUIPMENT.

REPLACE WITH INSULATION AND

TPO ROOF MEMBRANE

REMOVE EXISTING ROOF AND

ROOF MOUNTED EQUIPMENT.

REPLACE WITH INSULATION AND

TPO ROOF MEMBRANE

REMOVE EXISTING

ROOF AND ROOF

MOUNTED EQUIPMENT.

REPLACE WITH

INSULATION AND TPO

ROOF MEMBRANE

SLOPE

1/4" / FT

S L

O P

E

/4 " / F

T

S L

O P

E

/4 " / F

T

S L

O P

E

/4 " / F

T

S L

O P

E

/4 " / F

T

CRICKET CRICKET CRICKET

EXISTING PARAPET TO

REMAIN.

EXISTING PARAPET TO

REMAIN.

EXISTING PARAPET TO

REMAIN.

EXISTING PARAPET TO

REMAIN.

/A.751 073

A.601

S L

O P

E

/4 " / F

T

A.751

A.751

A.751

A.751

NEW ROOF DRAIN

AND OVERFLOW

SCUPPER WITH

DOWNSPOUT

ROOF DRAIN

AND OVERFLOW

SCUPPER WITH

DOWNSPOUT

EXISTING ROOF

DRAIN TO REMAIN

EXISTING ROOF

DRAIN TO REMAIN

EXISTING ROOF

DRAIN TO REMAIN

EXISTING ROOF

DRAIN AND

OVERFLOW

SCUPPER WITH

DOWNSPOUT TO

REMAIN

EXISTING ROOF

DRAIN AND

OVERFLOW

SCUPPER WITH

DOWNSPOUT TO

REMAIN

EXISTING ROOF

DRAIN AND

OVERFLOW

SCUPPER WITH

DOWNSPOUT TO

REMAIN

EXISTING ROOF

DRAIN AND

OVERFLOW

SCUPPER WITH

DOWNSPOUT TO

REMAIN

EXISTING ROOF

DRAIN AND

OVERFLOW

SCUPPER WITH

DOWNSPOUT TO

REMAIN

A.751

A.751

EQUIPMENT PAD

AT ROOF

EXHAUST

EQUIPMENT PAD

AT ROOF

EXHAUST

A.751

/A.751 16

ROOF PLAN GENERAL NOTES

1. ROOF TYPE: TPO OVER INSULATION

2. ALL ROOFING SURFACES TO SLOPE 1/4" VERTICAL PER

1' - 0" HORIZONTAL MINIMUM, U.N.O.

3. HATCHING INDICATES AREAS WHERE THE ROOF SLOPE

SURFACE SLOPE IS ACHIEVED WITH TAPERED INSULATION.

THE ROOF SURFACE SLOPE IN AREAS WITHOUT HATCHING

IS ACHIEVED WITH SLOPING STRUCTURE, U.N.O.

4. TOP OF INSULATION HEIGHTS, HIGH POINTS AND LOW

POINTS, ARE INDICATED AS THE TOP OF ROOF SURFACE

ABOVE THE ROOF DRAIN(S). (I.E. + 3.5" WHERE HIGH POINT

OF ROOF DRAIN SUMP IS +0"

5. REFER TO SHEET A.751 FOR TYPICAL ROOF DETAILS.

6. ALL ROOF TOP MECHANICAL, ELECTRICAL AND/OR

PLUMBING EQUIPMENT SHOWN FOR INFORMATION ONLY.

REFERENCE MECHANICAL, ELECTRICAL AND PLUMBING

DOCUMENTS AND SPECIFICATIONS FOR SPECIFIC DESIGN

INFORMATION.

7. PROVIDE WALKWAY PROTECTION TO MAJOR

MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT AS

REQUIRED TO PROVIDE SERVICE ACCESS. WALKWAY

PROTECTION IS INDICATED AS A GENERAL LAYOUT AND

MAY NOT SHOW ALL FINAL LOCATIONS OF ALL EQUIPMENT.

8. EXISTING ROOFS TO REMAIN, U.N.O.

9. REFERENCE DEMOLITION PLANS AND SECTIONS.

10. PATCH AND REPAIR EXISTING ROOFS DAMAGED

DURING CONSTRUCTION.

1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542designgroup

Architecture, Engineering, and Sustainable Design

AESUS

KEY PLAN NTS NORTH

Drawing Title: Project Title:

Date

Location

Checked

Building Number:

Project Number:

Drawing Number:

Drawn

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management

RENOVATE BUILDING 7 -

MENTAL HEALTH

Location:

Bid Set Submittal

APRIL 7, 2023

o n e e ig h th in c h o n e fo o t

B

A

C

D

E

F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t