This document is a Technical Inspection Report for the dehumidification plant at the Leghorn Army Depot in Italy. The report details the inspection of various components of the HVAC system, including the air ducts, air handling units, and air filters. It provides assessments of the system's cleanliness, microbial growth, and air flow measurements. The report identifies any issues or deficiencies found during the inspection, such as excessive particulate matter, mold growth, and non-compliant air flow rates. It also includes recommendations for maintenance and potential replacement of air filters. This Technical Inspection Report is related to a federal contract opportunity for the Maintenance and Repair of Dehumidification Plants at the Leghorn Army Depot, DMC, USAG Italy. The contract will be a hybrid firm-fixed price and time and material type, with a performance period of one base year and two option years.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ALLEGATO 6/Enclosure 6 - Rapporto di Prova dell'Ispezione Tecnica/Technical Inspection Report

DATE/DATE: _________________ TECNICO/TECHNICIAN: ________________________________ EDIFICIO/BLDG: ____________________________________

IDENTIFICAZIONE IMPIANTO/PLANT IDENTIFICATION (Identificare le componenti ispezionate e l'ubicazione/Identify the plant component inspected and their location)

LIMITI SITO ISPEZIONATO*

PARTICOLATO DEPOSITATO NELLE CONDOTTE 1 g/m2

CRESCITA DI MUFFE ASSENTE

CIRCOSRITTA E

MODERATA

ESTESA

E/O

DIFFUSA

ASSENTE

SEDIMENTI, DETRITI, RESTI DI ORIGINE ANIMALE ASSENTI PRESENTI - ASSENTI

CADUTA DI CARICO

NOMINALE DEI

FILTRI PULITI

CADUTA DI

CARICO RILEVATA

CON

MANOMETRO

DIFFERENZIALE

IL FILTRO

E'

ESAUSTO?

SI/NO

TEMPO PREVISTO DI ESAURIMENTO DEL FILTRO -

SITO/I ANOMALIA

VERIFICA DELLA PRESENZA DI SORGENTI CONTAMINATI INTERNE

L'uso di tutti gli ambienti climatizzati corrisponde a quanto previsto da progetto di impianto?

PORTATA DELL'ARIA AI TERMINALI DI MANDATA

La misura, a campione, della portata dell'aria ai terminali di mandata d'immissione corrisponde a quella prevista da progetto di impianto?

PARAMETRI MICROCLIMATICI (T, UR, V)*

I parametri microclimatici rientrano nei valori previsti per gli ambienti monitorati?

CARICA BATTERICA

UFC/g POLVERE

LIMITE DI

CONTAMINAZION

E BATTERICA

30.000 UFC/g

CARICA FUNGINA

UFC/g POLVERE

LIMITE DI

CONTAMINAZION

E FUNGINA

15.000 UFC/g

I BATTERI E I FUNGHI PRESENTI NELLE DIVERSE COMPONENTI

DELL'IMPIANTO POSSONO ESSERE TRASPORTATI DAL FLUSSO

D'ARIA NEGLI AMBIENTI CLIMATIZZATI E RAPPRESENTARE UN

RISCHIO PER LA SALUTE DEI LAVORATORI

VERIFICA DELLE CONDIZIONI IGIENICHE (CONDOTTE, UTA, SERRANDE) / VERIFY THE HYGIENIC CONDITIONS (DUCTS, AHU, SHUTTER)

*Specificare il sito ispezionato e la sua ubicazione nell'edificio

_________________________ g/m2

MISURAZIONE DELLA PORTATA DELL'ARIA A MONTE E A VALLE DEI CORPI FILTRANTI / AIR FLOW MEASUREMENT BEFORE AND AFTER THE FILTERS

LA DIFFERENZA DI PRESSIONE DELL'ARIA RILEVATA PRIMA E

DOPO I CORPI FILTRANTI DELL'UTA E' INDICATIVA DELL'ENTITA'

DELL'INTASAMENTO DEI FILTRI DERIVANTE DALLA PRESENZA DI

POLVERE E SPORCIZIA

NOTE

NOTE

NOSI

VERIFICHE NEGLI AMBIENTI DI LAVORO / INSPECTIONS AT WORK SITES

MONITORAGGIO MICROBIOLOGICO DELL'IMPIANTO: POLVERE / MICROBIOLOGICAL MONITORING OF THE PLANT: DUST

IN CASO DI RISPOSTA NEGATIVA

*T: Temperatura, UR: Umidita' Relativa, V: Velocita' dell'Aria