Attachment 10 Site Self Assessment XMatrix.xlsx

XLSX spreadsheet 328 KB Posted

Attached to
C1BG--402-22-700 EHRM Infrastructure Upgrades - Togus ME (VA-22-00030102)
Solicitation number
36C77622R0080
Issued by

About this file

This presolicitation notice is seeking Statements of Qualifications (SF 330) from firms for Architect-Engineering services related to EHRM infrastructure upgrades at the Togus VA Medical Center in Augusta, Maine. Key details include:

  • The project has an estimated construction value between $10-20 million. Required design disciplines include architecture, mechanical, electrical, plumbing, structural, civil, fire protection, and industrial hygiene.

  • Submissions are due by June 7, 2022. The selection process will include evaluating SF 330s followed by discussions with the most highly qualified firms. The highest rated firm will be notified for negotiations and potential award of a firm-fixed price design contract.

  • The project has a 100% SDVOSB set-aside. Evaluation criteria include specialized experience with IT and network infrastructure projects, professional qualifications of staff, capacity to complete the work on schedule, and past performance history. Knowledge of local conditions and experience with construction period services are also criteria.

  • The required upgrades address deficiencies identified in an infrastructure self-assessment of over 30 buildings and sites at the medical center campus. Work includes network backbone, structured cabling, electrical and UPS systems, HVAC, and telecom room renovations.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DropDown Values

Space UseUPSHVACSPACEDISTRICTTERRITORY
ADMINInstalled - AdequateInstalled - AdequateYESAdequate - Room for expansion1T1
CLINICALInstalled - InadequateInstalled - IndequateNOAdequate - No room for expansion2T2
OtherNot InstalledNot InstalledInadequate - makeshift installations3T3
ExcludeMissing dataMissing data4T4
5T5

XMATRIX Summary

StationLocationNameBuildingRoomCablingPatch PanelsFiberPowerBondingUPSDedicated CoolingTempHumidityRacks SensorsSpaceNotes
402TogusTogus VAMC & ROC200149XXXXXXXXXXX
402TogusTogus VAMC & ROC200152XXXXXXXXXXX
402TogusTogus VAMC & ROC200246XXXXXXXXXXX
402TogusTogus VAMC & ROC200315XXXXXXXXXXNO
402TogusTogus VAMC & ROC200New 4th FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC200New 5th FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC200New 7th FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC200635XXXXXXXXXXNOServices 3 floors
402TogusTogus VAMC & ROC200c006XXXXXXXXXXX
402TogusTogus VAMC & ROC200c103XXXXXXXXXXX
402TogusTogus VAMC & ROC200c203XXXXXXXXXXX
402TogusTogus VAMC & ROC200c303XXXXXXXXXXX
402TogusTogus VAMC & ROC200E305XXXXXXXXXXX
402TogusTogus VAMC & ROC200New E GroundXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC200New E 1st FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC200New E 2nd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC200New E 4th FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC2011XXXXXXXXXXXGrounds
402TogusTogus VAMC & ROC202TRXXXXXXXXXXX
402TogusTogus VAMC & ROC203105XXXXXXXXXXX
402TogusTogus VAMC & ROC203New 2nd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC203New 3rd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC204160AXXXXXXXXXXX
402TogusTogus VAMC & ROC204New 2nd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC204New 3rd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC205202XXXXXXXXXXX
402TogusTogus VAMC & ROC205New 1st FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC205New 3rd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC206213XXXXXXXXXXNO
402TogusTogus VAMC & ROC206New 1st FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC206New 3rd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC207201XXXXXXXXXXX
402TogusTogus VAMC & ROC207New 1st FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC207New 3rd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC208107XXXXXXXXXXX
402TogusTogus VAMC & ROC209New BasementXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC209New 1st FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC209209XXXXXXXXXXX
402TogusTogus VAMC & ROC210109XXXXXXXXXXNO
402TogusTogus VAMC & ROC210New 2nd FlNONONONONONONONONONONO2nd Floor Exception
402TogusTogus VAMC & ROC211107XXXXXXXXXXX
402TogusTogus VAMC & ROC212100XXXXXXXXXXX
402TogusTogus VAMC & ROC221100BXXXXXXXXXXX
402TogusTogus VAMC & ROC232202XXXXXXXXXXNOPool/Gym; 1st Floor Exception; not in scope
402TogusTogus VAMC & ROC232New 1st FlNONONONONONONONONONONO1st Floor Exception
402TogusTogus VAMC & ROC235New TRXXXXXXXXXXXNew TR; Chapel
402TogusTogus VAMC & ROC238104XXXXXXXXXXX
402TogusTogus VAMC & ROC240New TRXXXXXXXXXXXNew TR; Warehouse
402TogusTogus VAMC & ROC24815XXXXXXXXXXX
402TogusTogus VAMC & ROC24820NONONONONONONONONONONODemark; Not in scope
402TogusTogus VAMC & ROC248New 1st FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC248New 2nd FlXXXXXXXXXXXNew TR
402TogusTogus VAMC & ROC255106XXXXXXXXXXX
402TogusTogus VAMC & ROCBQ1BSMTXXXXXXXXXXXException for other floors; only 1 TR needed; not in scope
402TogusTogus VAMC & ROCBQ3New TRXXXXXXXXXXX
402TogusTogus VAMC & ROCBQ4BSMTXXXXXXXXXXX
402TogusTogus VAMC & ROCBQ27100XXXXXXXXXXX
402TogusTogus VAMC & ROCBQ32207XXXXXXXXXXX
402TogusTogus VAMC & ROCBQ69New TRXXXXXXXXXXX
402TogusTogus VAMC & ROC200SCA 1st FlXXXXXXXXXXXNew SCA Project 402-313
402TogusTogus VAMC & ROC200SCA 2nd FlXXXXXXXXXXXNew SCA Project 402-313
402TogusTogus VAMC & ROCCLC1TRXXXXXXXXXXXNew CLC Project 402-315
402TogusTogus VAMC & ROCCLC2TRXXXXXXXXXXXNew CLC Project 402-315
402TogusTogus VAMC & ROC300TRXXXXXXXXXXXFisher House
402TogusTogus VAMC & ROCMRITRXXXXXXXXXXX
402TogusTogus VAMC & ROC24815NONONONONONONONONONONONot in scope; duplicate
402TogusTogus VAMC & ROC248105XXXXXXXXXXNOVBA Data Center;
VAMC TOTALS6363636363636363636363574
StationLocationNameBuildingRoomCablingPatch PanelsFiberPowerBondingUPSDedicated CoolingTempHumidityRacks SensorsSpaceNotes
402M4TogusBANGOR CBOC190AXXNONOXXXXXXNOLease expires 1/9/2031
TogusBINGHAM CBOC100NONONONONONONONONONONOOut of scope; Closed
TogusBANGOR VET CEN120NONONONONONONONONONONOVet Center, out of scope
402HKTogusCALAIS CBOC110XXNONOXXXXXXNOLease expires 4/30/2025
402GATogusCARIBOU CBOC21BNONONONONONONONONONONOOut of scope; Lease expires 2/28/2022;
TogusCARIBOU VET CEN100NONONONONONONONONONONOVet Center, out of scope
TogusLEWISTON VET CEN100NONONONONONONONONONONOVet Center, out of scope
402GFTogusLINCOLN CBOC116XXNONOXXXXXXNOLease expires 1/31/2027
402M5TogusPORTLAND CBOC121NONONONONONONONONONONOLease expires 2/28/2022; New Portland CBOC in Construction; Out of scope
TogusPORTLAND VET CENATTICNONONONONONONONONONONOVet Center, out of scope
402GCTogusRUMFORD CBOC312NONONONONONONONONONONOBuilding new CBOC; Lease expires 5/31/2022; Out of scope
402GDTogusSACO CBOC235NONONONONONONONONONONOOut of scope; Lease expires 2/28/2022;
TogusSANFORD VET CEN100NONONONONONONONONONONOVet Center, out of scope
402GETogusLEWISTON CBOCTRXXNONOXXXXXXNOLease expires 12/12/2031
StationData CenterNameBuildingRoomSpaceHVACCable DistroWANUPSNOTES
402VA Maine HCSTogus VAMC & ROC209203XXXXXHVAC and UPS aging out
General Notes
X~included in scope of NRM project
NO~not included in scope
TR Notes
Cabling:
Fiber:
Power:
Data Center Notes
Existing Fiber may not meet needs; Need to connect higher speed fiber for JSA;
additional Fiber may be needed between core and DC ( one in DC and the other in entrance/PBX)
Vertical constraints; 1 ft Raised Floor;
Recommend new data center space; Stand alone DC construction
*CRACs:CRACS are 21 yrs old and failing, ductwork improperly designed
60 kW available
Cooling is adequate with distribution and reliability concerns.
*Power:UPSs are 15 years old
Eaton 150 kW
Is the Data Center able to accept the JSA and FDSS at the time of scoping?
JSA - ReadinessNot ready to accept: space constraints; cooling is adequate with distribution concerns; power is adequate but not redundant; Network core is split between two buildings, will need a fiber connection.
FDS -ReadinessNot ready to accept: space constraints; cooling is adequate with distribution concerns; power is adequate but not redundant; Network core is split between two buildings, will need a fiber connection.

Tab1-EUO-Room TR-DC-Assessment

IT INFRASTRUCTURE SURVEY
OITFMS for Column H OIT/FMSOITOIT/FMSOIT/FMSOITOITOIT
VA DISTRICT (1-5)VA IT TERRITORY (T1-T5)VHA VISN NumberVHA Station NumberOfficial Station NameSITE-Specific Station Site (Such as Division, CBOC, etc.)BUILDING NumberTR (Closet) or Data Center (DC) ROOM NUMBERROOM TYPEAREAS SERVEDROOM AREA TYPE CATEGORYUTP CABLE TYPE
(enter whole # to represent %)EVALUATION UTP CABLE TYPE-ROOMPATCH PANEL (Enter Whole Numbers)Patch Panel TypeEVALUATION PATCH PANELS-ROOMEVALUATION-PATCH CABLESFIBER-Enter Whole Numbers or Pick CategoryROOM FIBER EVALUATIONSatellite Site-LAN-Enter Whole Numbers or Pick Category Note: Satellite Sites are defined as sites "non VAMC" sites, such as CBOC's, Contract Clinics, Leased Space, Vet CentersSatellite-WAN
(enter circuit and outlet quantity in whole numbers)-VHAMissing DataNormal Power 208V 1ɸ (enter circuit and outlet quantity in whole numbers)-VHANormal Power 208V 3ɸ
(enter circuit and outlet quantity in whole numbers)-VHAEmergency Power 120V 1ɸ
(enter circuit and outlet quantity in whole numbers)-VHAMissing DataEmergency Power 208V 1ɸ
(enter circuit and outlet quantity in whole numbers)-VHAEmergency Power 208V 3ɸ
(enter circuit and outlet quantity in whole numbers)-VHAElectrical Bonding Bussbar Installed Yes/NoAre Outlets Adequate or Inadequate for Go-Live Readiness?Are Circuits Adequate or Inadequate for Go-Live Readiness?How Many UPS's Are Present?UPS (VHA)EVALUATION-UPSRoom HVACRoom HumidityCabinet/Rack ServerTR Closet or Data Center Dimensions (VHA), Measure to 2 decimal placesRoom ConditionEVALUATION-Room Condition ImpactSpace Issue CommentsEVALUATION SPACE DIMENSIONSCOMMENTS
Patient Care (Direct)Indirect and Non-Patient CareCat 3Cat 5Cat 5eCat 6Cat 6ATotal (Calculated)Is the Cable in the Room Cat 5e or Greater? If so, Cabling is considered Adequate for Go-Live Readiness. If not, Cabling is Inadequate.WALL Mount Total # of PortsRACK/FRAME Mount Total # of PortsIn Cabinet Mount Total # of PortsTOTAL # of Ports (Calculated)66-block Punch Down110-block Punch DownModular (RJ-45)Are the Patch Panels Adequate or Inadequate for Go-Live Readiness?Estimated UTP Cable Count
Whole Number EstimateDo patch cables in the closet meet or exceed the category ratings for their fixed cabling channels? YES-ADEQUATE/NO-INADEQUATE If NO, mismatched patch panels will require OIT remediation.Single-Mode StrandsSingle-Mode Fiber Run LengthSingle Mode Fiber Run Termination PointMulti-Mode StrandsMulti-Mode Fiber Run LengthMulti- Mode Fiber Run Termination PointIs the in the Room Fiber Adequate or Inadequate Go-Live Readiness?Single-Mode StrandsSingle-Mode Fiber Run LengthSingle Mode Fiber Run Termination PointMulti-Mode StrandsMulti-Mode Fiber Run LengthMulti- Mode Fiber Run Termination PointNumber of CircuitsAre there at least two diverse WAN circuits upstream from each CBOC? Yes/NoCircuit 1-BandwidthCircuit 1- TypeCircuit 1-CIR-Committed Information RateDemarcation (Bldg, Room)Describe Circuit 1 Path and ProviderCircuit 2-BandwidthCircuit 2- TypeCircuit 2-CIR-Committed Information RateDemarcation (Bldg, Room)Describe Circuit 2 Path and ProviderAre Satellite WAN Circuits Adequate/ Inadequate for Go-Live Readiness?15 Amp
Note: Data Center Rooms also include rooms with any servers that have non-OIT maintenance on the server.Clinic(s)/ Out-Patient ServicesDiagnostic (Imaging, Labs etc.)Procedure/Treatment (Surgery, ED, Endo, Chemo, etc.)InpatientPharmacyResidential (Dom, CLC, TR, Hoptel, etc.)Specific Area Listing (Free Text)Care Support (SPS,Transcription, etc.)Administrative/Office (Dir, Finance, FM, etc.)Specific Area Listing (Free Text)Clinical, Non-Clinical, or Mixed Clinical/Non-ClinicalWhole Number Count of Patch Panel TypeWhole Number Count of Patch Panel TypeWhole Number Count of Patch Panel TypeAre all Patch Panels Cat 5e or Greater? Yes/NoCat3Cat5Cat5eCat 6Cat6AIn useInstalledFiber TypePerformance 10 GbE (Building to Building)OS-Distance to Termination Point (Measured Length in feet)OS- Termination Point
(Building / Room)In useInstalledFiber Type OM1 (Orange)Fiber Type (OM2) OrangeFiber Type (OM3) AquaFiber Type (OM4) AquaPerformance 40 GbE (Intra-Building)OM-Distance to Termination Point (Measured Length in feet)OM- Termination Point
(Building / Room)In useInstalledFiber TypePerformance 10 GbE (Building to Building)OS-Distance to Termination Point (Measured Length in feet)OS- Termination Point
(Building / Room)In useInstalledFiber TypeOM-Distance to Termination Point (Measured Length in feet)OM- Termination Point
(Building / Room)In use CircuitsTotal Installed CirucuitsNumber of Outlets In UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets In UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets In UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in UseTotal Number of OutletsIn use CircuitsTotal Installed CircuitsNumber of Outlets in Use

* Does the room comply with the Telecommunications Infrastructure Standard?Adequate is defined as physical space exists to accommodate installation of commercially acquired racks, network switches, and patch panels.

An example of a "makeshift" installation would be where wall mounted patch panels are being used due to no rack space available. Or, "homemade" racks are being used to mount equipment due to size constraints.

Enter Either TR for Telecom Room (Closet) or DC for Data CenterYES/NOYES/NOYES/NOYES/NOYES/NOYES/NOYES/NOYES/NOEnter Clinical, Non-Clinical, or Mixed (Clinical and Non-Clinical)Mark Adequate or InadequateMark Adequate or InadequateWhole #Whole #OS1, OS2Select Either
OS1 – 10G up to 10Km OS2 – 100G up to 200KmWhole #Whole #Strand Count, Whole #Strand Count, Whole #Strand Count, Whole #Strand Count, Whole #Select One Below

OM1 – 1Gb up to 300M OM2 – 1Gb up to 600M OM3 – 40-100Gb up to 100M

OM4 – 100Gb up to 150MMark Adequate or InadequateWhole #Whole #OS1, OS2Select Either
OS1 – 10G up to 10Km OS2 – 100G up to 200KmWhole #Whole #OM1, OM2, OM3, OM4Whole #Mark Adequate or Inadequate
5T1VA Puget Sound(example)Seattle Division(example)1101TRMixed51550300100%Adequate288Inadequate1443144286YES412OS11/ B701012OM11/ B70Adequate412OS11/ B701012
1T11402Togus200149TRXXXXXXXX702010100%4811
1T11402Togus200152TRXXXXXXXX702010100%9622
1T11402Togus200246TRXXXXXXXX702010100%432
1T11402Togus200635TRXXXXXXXX702010100%528
1T11402Togus200c006TRXXXXXXXXMixed702010100%9622
1T11402Togus200c103TRXXXXXXXXMixed702010100%14422
1T11402Togus200c203TRXXXXXXXXMixed702010100%62466
1T11402Togus200c303TRXXXXXXXXMixed702010100%9622
1T11402Togus200E305TRXXXXXXXXMixed702010100%4811
1T11402Togus2011TRXXXXXXXXMixed702010100%4822
1T11402Togus203105TRXXXXXXXXMixed702010100%19222
1T11402Togus204160ATRXXXXXXXXMixed702010100%9622
1T11402Togus205202TRXXXXXXXXMixed702010100%38411
1T11402Togus206213TRXXXXXXXXMixed702010100%33622
1T11402Togus207201TRXXXXXXXXMixed702010100%24022
1T11402Togus208107TRXXXXXXXXMixed702010100%4822
1T11402Togus209224TRXXXXXXXXMixed702010100%96
1T11402Togus210109TRXXXXXXXXMixed702010100%9622
1T11402Togus211107TRXXXXXXXXMixed702010100%4822
1T11402Togus212100TRXXXXXXXXMixed702010100%4822
1T11402Togus221100BTRXXXXXXXXMixed702010100%481111
1T11402Togus232202TRXXXXXXXXMixed702010100%481111
1T11402Togus238104TRXXXXXXXXMixed702010100%4822
1T11402Togus24820TRXXXXXXXXMixed702010100%48
1T11402Togus255106TRXXXXXMixed702010100%4822
1T11402TogusBQ1BSMTTRXMixed702010100%4822
1T11402TogusBQ4BSMTTRXMixed702010100%4811
1T11402TogusBQ27100TRXMixed702010100%4811
1T11402TogusBQ32207TRXMixed702010100%481122
432T11402Togus24815TRXXXXXXXXMixed702010100%43222
1T11402Togus248105TRXMixed702010100%240
1T11402TogusBANGOR CBOC190ATRXXXXXMixed702010100%288YES10MBMetro E10 MBCentiryLink1.5MbpsDS-11.5MbpsAT&T
1T11402TogusBINGHAM CBOC100TRXXXXXMixed702010100%48NO1.5MbpsDS-11.5MbpsAT&T
1T11402TogusBANGOR VET CEN120TRXVET CENTERXVET CENTERMixed702010100%48NO100MBMetro E100 MBCenturyLink
1T11402TogusCALAIS CBOC110TRXXXXXMixed702010100%48NO30MBMetro E30 MBCenturyLink
1T11402TogusCARIBOU CBOC21BTRXXXXXMixed702010100%48YES1.5 MbMPLS3MbCenturyLink30MBMetro E30MBAT&T
1T11402TogusCARIBOU VET CEN100TRXVET CENTERXVET CENTERMixed702010100%48YES1.5MBMPLS1.5MBCenturyLink1112000
1T11402TogusLEWISTON VET CEN100TRXVET CENTERXVET CENTERMixed702010100%240YES1.5MBMPLS1.5MBCenturyLink1.5MbMPLS1.5MBAT&T
1T11402TogusLINCOLN CBOC116TRXXXXXMixed702010100%48YES30MBMetro E30 MBAT&T
1T11402TogusPORTLAND CBOC121TRXXXXXMixed702010100%144NO30MBMetro E30 MBAT&T
1T11402TogusPORTLAND VET CENATTICTRXVET CENTERXVET CENTERMixed702010100%48NO1.5MBMPLS1.5MBCenturyLink0000113
1T11402TogusRUMFORD CBOC312TRXXXXXMixed702010100%96NO30MBMetro E30MBCenturyLink
1T11402TogusSACO CBOC235TRXXXXXMixed702010100%96YES4.5 MbpsDS-1x34.5MbpsCenturyLink30MBMetro E30MBAT&T
1T11402TogusSANFORD VET CEN100TRXVET CENTERXVET CENTERMixed702010100%48YES1.5MbpsMPLS1.5MbpsCenturyLink1.5MbpsMPLS1.5MbpsCenturyLink0000111
1T11402TogusLEWISTON CBOCMixed702010100%240YES30MBMetro E30 MBCenturyLink30MBMetro E30MBAT&T
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%00000343418180000
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%
0%

Tab2-DC Room Data Collection

OITFMSOITOITOIT/FMSOITFMS (with OIT as needed)FMSOITOIT
VA DISTRICT (1-5)VA IT TERRITORY (T1-T5)VHA VISN NumberVHA Station NumberOfficial Station NameSITE-Specific Station Site (Such as Division, CBOC, etc.)BUILDING NumberCloset ROOM NUMBERROOM TYPE is Data CenterData Center Assessment Team
Site LayoutRacksSPACE EVALUATIONENVIRONMENTALENVIRONMENTALCOOLING EVALUATIONEVALUATION COMMENTSCable DistributionCABLING AND DISTRIBUTION EVALUATIONWAN
GENERAL NOTES: FOR MEASUREMENTS, USE 2 DECIMAL PLACES. FOR COUNTS, WHOLE NUMBERSARCHITECTUREARCHITECTUREARCHITECTUREARCHITECTUREMECHANICALMECHANICAL-SYSTEM 1 SECTIONMECHANICAL-SYSTEM 2 SECTIONMECHANICAL-SYSTEM 3 SECTIONMECHANICAL-TOTAL ROOM COOLING CAPACITYENVIRONMENTAL/MECHANICALENVIRONMENTAL/MECHANICALTELECOMMUNICATIONSTELECOMMUNICATIONSTELECOMMUNICATIONS
Date Of Survey (MM/DD/YYYY)Survey Team -List First and Last NamesSite Plan Yes or NoFloor Plan Yes or NoFrom TR/Closet Tab: Rm. Length (ft)From TR/Closet Tab: Rm. Width (ft)Number of 2-Post RacksNumber of 4 Post RacksNumber of CabinetsTotal Number of Racks (all types) and CabinetsMeasure (ft/in)/Check Access Path Clearance for moving cabinets/rack in and out of doors. Any issue with installing 84.6" high by 30"wide cabinets on pallet? Yes/NoDoes site have a raised floor Yes/NoRaised Floor Height (ft)Do you have enough space and access clearance (Adequate/Inadequate) to deploy 4 additional cabinets?Description of Cooling Distribution System Description Categories: Fully Ducted , Hot-Cold Aisle, No Air ContainmentNumber of UnitsUnit Redundancy: Select from None (N), Redundant (N+1), Parallel Redundant (2N), OtherSystem 1 MakeSystem 1 ModelSystem 1 Age (from Manufacturer Datecode which gives Mfr Date or Install Date)System 1-Total Room Available Cooling Capacity (kW) Note: From TR/Closet Tab, Convert "Tons to kW" .System 2 MakeSystem 2 ModelSystem 2 Age (from Manufacturer Datecode which gives Mfr Date or Install Date)System 2-Total Room Available Cooling Capacity (kW) Note: From TR/Closet Tab, Convert "Tons to kW" .System 3 MakeSystem 3 ModelSystem 3 Age (from Manufacturer Datecode which gives Mfr Date or Install Date)System 3-Total Room Available Cooling Capacity (kW) Note: From TR/Closet Tab, Convert "Tons to kW" .Total Room Available Cooling Capacity (kW) Note: after considering Redundancy.Total Critical Load on Cooling System (UPS Output Load) (kW)Available Cooling Capacity (kW) = (Total Available Cooling)-(Total Critical Load on Cooling System)Cooling System Sufficient to support additional workload (Adequate/Inadequate)Cooling Comments (Enter Data for additional cooling systems here)Telecommunications cable trays (Yes/No)Structured cabling system used (Yes/No)Dedicated Redundant Horizontal Distribution Area for the Main Computer Room (Yes/No)Dedicated Redundant Main Distribution Area (Yes/No)Is Cabling and Distribution Adequate/Inadequate for Data Center?Number of CircuitsAre there at least two diverse WAN circuits upstream from each VAMC? Yes/No
5T1VA Puget Sound(example)Seattle Division(example)1101DC
111402VA Maine HCSN/A209203Data Center1/27/20Andrew Cook, Chris CurtisYesYes5813101618NoYes1NOLiebert Floor Units - raised floor4N+1LiebertBF067A-CAM21 yr old35.2 KWLiebertBF067A-CAM21 yr old35.2 KW70.435.2NORETURN DUCTWORK NOT ADEQUATELY LOCATED CAUSING SHORT CYCLING OF UNITS. LIEBERT UNITS ARE 21 YEARS OLD AND FAIL IN HOT WEATHER.YESNoNONO2Yes

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .