This presolicitation notice seeks SF 330 qualification packages from firms for an Architect-Engineering contract to provide design services. Key details include:

  • The project is to design EHRM infrastructure upgrades at the Canandaigua VA Medical Center in Canandaigua, New York, with an estimated construction value between $10-20 million. Required services include network infrastructure installation, IT system renovations and upgrades, electrical and mechanical work.

  • The contract will be awarded by September 2022. The anticipated period of performance for design completion is 365 calendar days from notice to proceed.

  • Evaluation criteria are specialized experience designing similar IT and network infrastructure projects within the past 5 years, professional qualifications and licensing of staff, capacity to complete the work on schedule, and past performance on government and private sector projects.

  • Submissions are due by July 1, 2022 and must not exceed 30 pages. The solicitation is a 100% SDVOSB set-aside. Firms must be verified as SDVOSBs by the time of submission.

View the file

Other files for this federal contract opportunity

Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Station Location Name Building Room Cabling

Patch

Panels Fiber

528a5 Canandaigua VAMC Main Campus 1 207 NA NA NA

528a5 Canandaigua VAMC Main Campus 1 302 NA NA NA

528a5 Canandaigua VAMC Main Campus 1 10 NA NA NA

528a5 Canandaigua VAMC Main Campus 1 TR-4 NA NA NA

528a5 Canandaigua VAMC Main Campus 2 TR1-1 NA NA NA

528a5 Canandaigua VAMC Main Campus 2 TR1-2 NA NA NA

528a5 Canandaigua VAMC Main Campus 2 TR2-3 NA NA NA

528a5 Canandaigua VAMC Main Campus 2 TR2-4 NA NA NA

528a5 Canandaigua VAMC Main Campus 3 TR-1 NA NA NA

528a5 Canandaigua VAMC Main Campus 3 TR-1 NA NA NA

528a5 Canandaigua VAMC Main Campus 3 TR-3 NA NA NA

528a5 Canandaigua VAMC Main Campus 4 TR-1 NA NA NA

528a5 Canandaigua VAMC Main Campus 4 TR-2 NA NA NA

528a5 Canandaigua VAMC Main Campus 4 TR-3 NA NA NA

528a5 Canandaigua VAMC Main Campus 5 6 X X X

528a5 Canandaigua VAMC Main Campus 6 1a X X X

528a5 Canandaigua VAMC Main Campus 6 TR2-1 NA NA NA

528a5 Canandaigua VAMC Main Campus 6 TR2-2 NA NA NA

528a5 Canandaigua VAMC Main Campus 7 14 X X X

528a5 Canandaigua VAMC Main Campus 8 1a X X X

528a5 Canandaigua VAMC Main Campus 9 10 NA NA NA

528a5 Canandaigua VAMC Main Campus 9 10 NA NA NA

528a5 Canandaigua VAMC Main Campus 9 10 NA NA NA

528a5 Canandaigua VAMC Main Campus 10 1 X X X

528a5 Canandaigua VAMC Main Campus 11 1a X X X

528a5 Canandaigua VAMC Main Campus 12 1a NA NA NA

528a5 Canandaigua VAMC Main Campus 16 11 NA NA NA

528a5 Canandaigua VAMC Main Campus 20 Basement NA NA NA

528a5 Canandaigua VAMC Main Campus 33 7a NA NA NA

528a5 Canandaigua VAMC Main Campus 34 9a NA NA NA

528a5 Canandaigua VAMC Main Campus 36 13 X X X

528a5 Canandaigua VAMC Main Campus 36 132 X X X

528a5 Canandaigua VAMC Main Campus 36 TR-3 X X X

528a5 Canandaigua VAMC Main Campus 37 TR-4 X X X

528a5 Canandaigua VAMC Main Campus 37 137 X X X

528a5 Canandaigua VAMC Main Campus 37 7c X X X

528a5 Canandaigua VAMC Main Campus 37 7d X X X

528a5 Canandaigua VAMC Main Campus 37 6 X X X

528a5 Canandaigua VAMC Main Campus 118 9 X X X

39 15 15 15

Station Data Center Building Building Room Space HVAC Cable Distro

528a5 Canandaigua VAMC Main Hospital 37 7 NO X X

JSA Half rack of space. Power and cooling ok, but not redundant.

FDS space available, but constrained. Cooling and power not redundant. Critical load on UPS

X ~included in scope of NRM project

NO ~not included in scope

TR Notes

Cabling:

Fiber:

Power:

Data Center Notes

*CRACs:

General Notes

VAMC TOTALS

Power Bonding UPS

Dedicated

Cooling Temp Humidity Racks Sensors Space

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

X X X X X X X NO

X X X X X X X NO

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

X X X X X X X X

X X X X X X X NO

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

X X X X X X X X

X X X X X X X X

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

NA NA NA NA NA NA NA NA

X X X X X X X NO

X X X X X X X X

X X X X X X X X

NA NA NA NA NA NA NA NO

NA NA NA NA NA NA NA NA

X X X X X X X X

X X X X X X X NO

13 13 13 13 13 13 13 8

WAN UPS

X X

NOTES

Need HVAC, Notes

Space good >200 sqft. Part of CARES MAJOR project is covering all of Building 1. Will mod scope to include EHRM requirements

Space good >200 sqft. Part of CARES MAJOR project is covering all of Building 1. Will mod scope to include EHRM requirements

Space good >200 sqft. Part of CARES MAJOR project is covering all of Building 1. Will mod scope to include EHRM requirements

Space good >200 sqft. Part of CARES MAJOR project is covering all of Building 1. Will mod scope to include EHRM requirements

Space 200 sqft. Part of CARES MAJOR project is covering all of Building 2. Will mod scope to include EHRM requirements

Space 200 sqft. Part of CARES MAJOR project is covering all of Building 2. Will mod scope to include EHRM requirements

Space 200 sqft. Part of CARES MAJOR project is covering all of Building 2. Will mod scope to include EHRM requirements

Space 200 sqft. Part of CARES MAJOR project is covering all of Building 2. Will mod scope to include EHRM requirements

200 sqft. Part of CARES MAJOR project is covering all of Building 4. Will mod scope to include EHRM requirements

200 sqft. Part of CARES MAJOR project is covering all of Building 4. Will mod scope to include EHRM requirements

200 sqft. Part of CARES MAJOR project is covering all of Building 4. Will mod scope to include EHRM requirements

216 sqft. Part of CARES MAJOR project is covering all of Building 4. Will mod scope to include EHRM requirements

216 sqft. Part of CARES MAJOR project is covering all of Building 4. Will mod scope to include EHRM requirements

213 sqft. Part of CARES MAJOR project is covering all of Building 4. Will mod scope to include EHRM requirements

Space good

Adequate space, 13'x9'.

Adequate space, 13'x9'. Construction complete, awaiting hand-off from contractror. Part of project 528A5-17-526.

Adequate space, 13'x9'. Construction complete

Moving to cottages

Moving to cottages

Space good. Part of CARES MAJOR project is covering all of Building 9. Will mod scope to include EHRM requirements

Space good. Part of CARES MAJOR project is covering all of Building 9. Will mod scope to include EHRM requirements

Space good. Part of CARES MAJOR project is covering all of Building 9. Will mod scope to include EHRM requirements

Install conditioned box for space

Install conditioned box for space

Project in design for reno for new Boiler Plant 528A5-20-502 part of project

Will be demolished or vacated. No EHRM infrastructure required.

Will be demolished or vacated. No EHRM infrastructure required.

Will be demolished or vacated. No EHRM infrastructure required.

adequate space new TR for second floor

New room for 2nd floor

Data Center? 931ft2. Treat as TRs in scope for TR will relocate to main data center

237ft2 cage within electric room

NOTES

Need HVAC,