Attachment 1 Warehouse DB Contract design CSF Bridging Documents 9.23.2020 (1).pdf
PDF 1 MB Posted
- Solicitation number
- 72066821R00002
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 72066821R00002 RFP for Warehouse DB 11.6.2020.pdf | ||
| Attachment 2 Past Performance Information Sheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SE
NS
IT
IV
E
BU
T
UN
CL
AS
SI
FI
ED
SI
TE
LO
CA
TI
O N
PL
AN
DO
N
O T
SC
AL
E 9/
/2
DW
G.
o f 9
UP
Stairs B
UP
Stair A
UP
St air s C
W a l k w a y
W a l k w y
L G
F
P t r u t e u t e
L G F P a t r o l r o u t e
L G F P a t r o l r o u t eL G F P a t r o l r o u t e Sliding gate
P a r k i n g - l o t
R O A D
R
O
A
D
N E I G H B O R
N
E
I
H
B
RA B C D
F
G
H
1 2 3 4 5 6 8
15.6m atea
6m 6m2m1m
0.6m
Prefab guard booth Enclosed extension
New entrance gate 6m wide
I
G ra nu la rl ay
-d ow n ar ea G ra nu la r
G ra nu la r G ra nu la la y-do w n do w n la y-d la y-do w n ar ea ar ea ar ea
6m (20ft) shipping container
12m (40ft) shipping container
E
F
G
H
I
AB
O
UN
DI
NG
P
RO
PE
RT
Y
ABOUNDING PROPERTY
PRIMROSE ROAD
SENSITIVE BUT UNCLASSIFIED SHIPPING CONTAINER LAYOUT
09/19/20Do not scale DWG. 2 of 9
Varies 2.4m to 2.7m
Land slope varies in all directions
Existing perimeter wall
EXISTING TYPICAL CROSS-SECTION
Varies to allow for ground to top height of 2.7m minimum
Container load supporting reinforced concrete slab
Guard patrol walkway
Concrete parapet
2% slope
Unpaved driveway varies 5m to 6m
1200mm1200mm Varies 6m or 12 m container
Remove unsuitable to 300mm average
SECTION DETAILS NEW CONSTRUCTION
SECTION A-A (TYPICAL)
250mm road base
250 sub-base
Finished elevation
Existing ground elevation
Additional excavation (if required) 200m deep; 200mm sub-base backfill
Existing Perimeter Wall
Excavation & Backfill DWG D07
Do not scale07/2020
Varies E-W or N-S Varies E-W or N-S
SECTION A-A
BACKFILL
Container Lay-down Area ContainerRoadway Roadway
EXISTING EXCAVATION & BACKFILL (BY OTHERS)
SENSITIVE BUT UNCLASSIFIED EXISTING FILL AS BY OTHERS DO NOT SCALE DWG: 3 of 909/16/2020
(varies from 1.5% to 2.5%) beams 1200mm deep x 750mm square
Area has been previously excavated & backfilled by Others See profile as by Others rampramp
Concrete moisture & erosion barrier
EXISTING PERIMETER
WALL SECTION
SENSITIVE BUT UNCLASSIFIED WALL & LAND SECTION DO NOT SCALE 09/16/2020 DWG: 4 of 9
Riser to allow for a minimum of 2.7m high from outside of perimeter walls.
Riser type to ensure existing block wall can support load Recommended riser types are concrete block wall; concrete or chain-link fence
UP
Stairs B
UP
Stair A
UP
St air s C
W a l k w a y u t e u t e
L G F P a t r o l r o u t e
L G F P a t r o l r o u t eL G F P a t r o l r o u t e Sliding gate
P a r k i n g - l o t
R O A D
R
A
D
N E I G H B O R
N
I
H
B
RA B C D
F
G
H
1 2 3 4 5 6 8
15.6m atea
6m 6m2m1m
0.6m
Prefab guard booth Enclosed extension
New entrance gate 6m wide
I
G ra nu la rl ay
-d ow n ar ea G ra nu la r
G ra nu la r G ra nu la la y-do w n do w n la y-d la y-do w n ar ea ar ea ar ea
X
X E
F
G
H
I
Beam is non-continuous Each beam @ maximum span 5m (typical)
ABOUNDING PROPERTY
AB
O
UN
DI
NG
P
RO
PE
RT
Y
Zone 1
Zone 2 Zone 3 Zone 4
Zone 5
Covered walkway D1 D2
SENSITIVE BUT UNCLASSIFIED GRADE BEAM LAYOUT DO NOT SCALE 09/16/2020 DWG: 5 of 9
1200mm
750mm
125mm thick moisture & erosion barrier concrete slab
Finished walkway or ground elevation where applicable
Compacted fill
200mm
6m (20ft) container/Typical
12m (40ft) container/ Typical
Y20@ 150mm c/c all sides
Stirrup Y15 @ 200c/c Y15 @ 200 c/c
Welded wire mesh 100mm x 100mm square 11 gauge minimum
125mm
25mm below top of beam
SECTION X-X
BEAM & SLAB DETAILS
1200mm X 750MM typical concrete beam
Top of concrete walkway or road or fill (where applicable)
Central beam top at 75mm above outer beams
18mm bituminous impregnated filler board
18mm Bituminous joint filler
SENSITIVE BUT UNCLASSIFIED DO NOT SCALE 09/16/2020GRADE BEAM SECTION DETAILS DWG: 6 of 9
D1 D2 Existing Door D3
Lightweight prefabricated wall panel & D3 Bath stall
New walls & door Walls/aluminum panels Door/ glass & aluminum frame
Prefabricated Hardened Container (2800mm high) 6000mm x 2400mm external dimensions
Metal covered walkway/no enclosure 1500mm wide x 4000mm
New Extension
W1
W2 1800mm x 2400mm
Notes:
The guard booth to be a 2-man station Prefabricated hardened container is a used unit; USG owned.
Toilet & bath to be installed including new wall panel & D3.
D2 is existing.
Allow for 3 ceiling lights in the prefabricated unit; this includes 1 for the restroom.
Allow for repainting. all exposed surfaces
New guard booth extension:
Walls to be hollow concrete blocks (150mm x 200mm x 400mm);
reinforced in each block core; cast in-situ concrete infill.
Roof to be over new extension only.
D1/ semi-vision panel; glass with shatter proof film; minimum 4 mm thick glass; aluminum framing and non-glass panel W1 & W2/Aluminum & glass (anti-shatter film); minimum 4mm glass.
Services: 12,000 BTU/AC; 2 ceiling lights; 4 wall outlets (double port; standard) Tiled floor finish.
GUARD BOOTH DETAILS
SENSITIVE BUT UNCLASSIFIED GUARD BOOTH DETAILS DO NOT SCALE 09/16/2020 DWG: 7 of 9
Angle iron 100mm x 100mm x 12mm thick All external corners or 4 per bay @ every level
(Typical)
200mm
12mm plate 200mm x 150mm @ 2000mm along length
(Typical)
300mm to edge of plate at all corners
Medium carbon steel, quenched and tempered
Container
Concrete slab
Detail A
DETAIL A
SENSITIVE BUT UNCLASSIFIED
CONTAINER- CONTAINER WELDED CONNECTION
CONTAINER- CONCRETE CONNECTION DO NOT SCALE 09/16/2020 DWG: 8 of 9
Notes:
C1/1; C1/2 ; C1/3 designation type means container on ground; 2nd or 3rd level respectively The connection details must be checked for stability as part of the design.
The details show recommended connections along the 6m or 12m containers run of the containers.
Detail A
12mm steel plate 200mm x 150mm 2400mm c/c (Typical)
12mm steel plate 200mm x 200mm 2400mm c/c (Typical)
12mm steel plate 200mm x 150mm 2400mm c/c (Typical)
CONCRETE TO CONTAINER CONNECTION
C1/1
C2/1
C1/2
C1/3
C1/1
C1/2 C2/2
C1/3 C2/3
Beam
Container
CONTAINER TO CONTAINER
6m or 12m Side
CONTAINER TO CONTAINER
2.4m front face
OPTIONAL GEOMETRIC STACKING
FOR SLOPING SURFACES
Grade beam Grade beam
Walkway to carry riser or ramp at elevation change points
C1/1
C1/2
C1/3
SENSITIVE BUT UNCLASSIFIED OPTIONAL STACKING
FOR SLOPING SURFACES
DO NOT SCALE 09/16/2020 DWG: 9 of 9
Moisture barrier at Elevation Change Point Y (Typical)
Y
Notes The final slope of the existing land to be determined as part of the design Additional steel plate connection to be added (if required) for both container- container or container - concrete interfaces
File details come from the government source that posted it. Updated .