Attachment 1 - STC PRD Requirements Thresholds and Objectives.xlsx
XLSX spreadsheet 29 KB Posted
- Solicitation number
- 70RWMD25RFI00000010
About this file
This document is a detailed Technical Requirements Matrix for a Personal Radiation Detector (PRD) for the Countering Weapons of Mass Destruction (CWMD) Securing the Cities (STC) program. The comprehensive spreadsheet outlines 41 operational requirements and 12 functional requirements for a gamma radiation detection device, specifying both threshold and objective performance standards across multiple technical domains including radiation detection capabilities, cybersecurity, physical characteristics, environmental durability, battery performance, and data transmission.
Key technical specifications include detection sensitivity requirements (80-95% probability of detection), alarm capabilities (visual/audible/vibration), cybersecurity protocols, compact physical dimensions (10-12 cm x 6.5-8 cm x 3.5-4 cm), maximum weight of 240-400 grams, battery life of 24-168 hours, operational temperature range of -20°C to +50°C, and compatibility with Android 12+/iOS 16+ mobile devices. The document is part of a pre-solicitation Request for Information (RFI) by the Department of Homeland Security's Office of Procurement Operations, seeking commercial off-the-shelf (COTS) gamma detecting PRDs for market research purposes.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI Notice 70RWMD25RFI00000010- STC PRD FY25.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Operational Requirements | |||||
| OR# | Operational Requirement | Threshold | Objective | Clarification | Meets or Does Not Meet |
| Reference/ Explanation | Available Test Data |
| PRD-OR-01 |
KPP-1 The STC PRD shall have T/O radiation detection capability.
| Amplifying Information: PRDs with detector materials that are designed to detect neutron radiation may not be submitted for evaluation. PRDs with neutron detectors built-in but disabled by the manufacturer with no way for the operator to re-enable this function may be submitted for evaluation. | Gamma only | Same as Threshold | Requires 3rd party independent testing at a minimum to substantiate claim of “meets.” |
| PRD-OR-02 | The STC PRD shall have cumulative Probability of Detection (Pd) of T/O. |
Amplifying Information: In this context, the probability of detection (Pd) is a statistical measure of the likelihood that the sensor (PRD) clearly detects the presence of ionizing radiation it is intended to monitor for. Include multiple points for Pd assessment.
| See FR-01 | 80% | 95% |
| PRD-OR-03 |
KPP-2 The STC PRD shall have T/O alarm types.
Amplifying Information: At least one type of alarm must be operational under any configuration of the PRD. In other words, it shall not be possible to deactivate all alarms at the same time.
| See FR-02 and FR-03 | Visual, audible, and vibration (tactile) | Same as Threshold | Requires 3rd party independent testing at a minimum to substantiate claim of “meets.” |
| PRD-OR-04 | While in “Vibrate Only” mode, all STC PRD T/O shall be automatically disabled. |
| Amplifying Information: The PRD shall have a minimum of two alarm modes. One in which all three types of detection alarms (visual, audible, and vibrate) are fully functional and one in which only the vibration alarm is active. The display shall still be visible and readable without the requirement of a backlight. The requirement that at least one type of alarm must be operational under any configuration of the PRD (OR-03) still applies. | Lighted indicators (e.g., LED, display backlight, etc.) | Same as Threshold |
| PRD-OR-05 | The STC PRD false alarm rate for gamma radiation shall be T/O. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 6.1. The threshold and objective values assume the PRD is operated in a stable background environment. A false alarm is defined as either a false positive or a false negative. A false positive is a situation in which the PRD alarms indicating the presence of ionizing radiation when no radiation source exists. A false negative is a situation in which the PRD fails to alarm when in the presence of an ionizing radiation source. Test data should provide context to the results in case one or more devices do not meet this requirement. | ≤ 0.25 per hour | ≤ 0.125 per hour |
| PRD-OR-06 | The STC PRD shall alarm in T/O after reaching a distance of closest approach to a gamma source for 19 out of 20 trials. |
| Amplifying Information: IAW ANSI N42.32, 2016, Section 6.2. Increase exposure rate to 50 μR/h above background at a distance of closest approach of 1.5 m and a speed of 1.2 m/s. Test data should provide context to the results in case one or more devices do not meet this requirement. | ≤ 2 s | ≤ 1 s |
| PRD-OR-07 | The STC PRD Time to Alarm threshold (OR-06) shall not be affected by slowly increasing radiation levels when approaching a radiation source at a speed of T/O for 10 out of 10 trials. |
Amplifying Information: Per ANSI N42.32, 2016, Section 6.4 (gamma only) start at background. Move the source at the speed indicated by the threshold or objective values to produce an exposure rate of 50 μR/h at the distance of closest approach (1.5m). Test data should provide context to the results in case one or more devices do not meet this requirement.
| See FR-04 | 0.5 m/s | 1.5 m/s |
| PRD-OR-08 |
KPP-3 The STC PRD shall have a minimum overload threshold of at least T/O.
| Amplifying Information: When exposed to an exposure rate that is two times the maximum dose rate/exposure rate (OR-38) or higher, the PRD shall alarm, the alarm shall remain active, and an over-range indication shall be displayed for the duration of the over-range exposure. PRDs with an overload threshold of less than two times the maximum dose rate/exposure rate (OR-38) threshold may not be submitted for evaluation. Test data should provide context to the results in case one or more devices do not meet this KPP requirement. | 25 mR/h | 1 mR/h | Requires 3rd party independent testing at a minimum to substantiate claim of “meets.” |
| PRD-OR-09 | The STC PRD shall display an over-range condition and recover from the over-range field within T/O. |
Amplifying Information: IAW ANSI N42.32 2016, Section 6.6, the manufacturer shall state the exposure rate for which the over-range indication is displayed. When exposed to an exposure rate that is two times the maximum exposure rate specified by the manufacturer, the indication of the PRD shall remain at the maximum of the range, and an over-range indication shall be displayed for the duration of the exposure. The PRD shall provide the same initial exposure rate value as the one before the PRD was exposed to the radiation field within 1 min after the radiation field is reduced. If the exposure rate value is not provided the test cannot be performed and the PRD fails the test. Test data should provide context to the results in case one or more devices do not meet this requirement.
| See FR-05 | 2 minutes | 1 minute |
| PRD-OR-10 | The STC PRD shall display radiation levels in one or both of the T/O formats. |
Amplifying Information: IAW ANSI N42.32 2016, Section 5.8, the PRD only needs to have one of the two display formats and the display may be backlit, except as indicated in OR-04. The PRD itself shall have a display in addition to the user interface of a mobile device if a mobile application is used. Test data should provide context to the results in case one or more devices do not meet this requirement. Digital display: The PRD directly displays the measured exposure rate, dose rate, ambient dose equivalent rate or count rate (e.g., μR/h or cps).
| Unit-less display: The PRD displays a numerical value (e.g., 1 to 9) that may be proportional to the radiation field but is not explicitly reported as the exposure, dose or ambient dose-equivalent rate or count rate. | Same as Threshold except the PRD has both types of displays and the operator can choose which display to view. | |
| PRD-OR-11 | For STC PRDs with a displayed exposure rate, the displayed exposure rate shall be within T/O of the 137Cs exposure rate of the applied field. |
For STC PRDs with a unit-less display, the displayed numerical value (e.g., 1 to 9) shall equate to the T/O.
Amplifying Information: IAW ANSI N42.32 2016, Section 6.5.1, the manufacturer shall provide the maximum exposure rate value or a conversion table to convert the displayed value to an exposure rate. Test data should provide context to the results in case one or more devices do not meet this requirement.
For PRDs with a “Displayed” exposure rate, the manufacturer shall provide the maximum exposure rate value for the PRD. If the value is not provided, then the PRD shall be tested assuming a maximum exposure rate value of 2 mR/h.
For PRDs with unit-less displays, the manufacturer shall provide a conversion table to convert the displayed numerical value to an exposure rate. If the manufacturer does not provide a conversion table, then the PRD cannot be tested and the device shall fail the test. (Displayed) ±30%
(Unit-less display) - 137Cs exposure rate field corresponding to the middle value (of the exposure rate range) for the displayed numerical value. (Displayed) ±20%
(Unit-less display) - 137Cs exposure rate field corresponding to the middle value (of the exposure rate range) for the displayed numerical value.
PRD-OR-12 The STC PRD shall provide cybersecurity protection to Bluetooth (BT) communications using T/O.
Amplifying Information: The vendor shall provide a detailed description of the Bluetooth protocols used, to include but not limited to:
• The level of security.
• Method of pairing.
• Type of encryption used.
In accordance with DHS Policy Directive 4300A Handbook Attachment 6 [16], the BT connection shall be configured such that:
• Bluetooth functionality shall be disabled when the PRD is not in use.
• The PRD only allows manual pairing and prompts the user to authorize any incoming connection requests; auto pairing may not be implemented.
• The PRD shall be in non-discoverable mode, except during device pairing.
| • Devices shall use Bluetooth low energy option to minimize the range of communication. | BT 4.1 specification or higher with FIPS approved algorithm (NIST SP 800-121 REV. 2) | Same as Threshold |
| PRD-OR-13 | The STC PRD shall have unique T/O identifiers. |
Amplifying Information: Consistent with DHS Policy Directive Number: 4300A, V13.3 2023, Information Technology System Security Program, Sensitive Systems:
• Unique logical identifiers shall not be reused.
• Unique logical identifiers shall be included on all communication interfaces (e.g., Media Access Control address on network connections, System ID on BT connections) in accordance with industry standards.
| • Unique physical identifier (e.g., serial number bar code) will be provided by the government. | Logical and physical | Same as Threshold |
| PRD-OR-14 | If applicable, any future changes made to the STC PRD device software shall require T/O authentication. |
Amplifying Information: There is no requirement for the PRD to have software that is updateable by CWMD or the end-user; however, if it does this requirement applies. Consistent with DHS Policy Directive Number: 4300A, V13.3 2023, Information Technology System Security Program, Sensitive Systems:
• A group authenticator shall be considered a single authenticator (e.g., password, passcode) used per device. An individual authenticator shall be considered a discrete authenticator (e.g., personal identification number [PIN]) per individual user, normally associated with a user identifier.
• Authentication may be made at the PRD level or as part of the setup software.
• Software updates can use certificates to validate the authenticity of the update.
• If applicable the vendor shall provide design documentation that describes the security features of the PRD.
| The manufacturer shall notify CWMD what modifications are made during each update. | Group | Individual |
| PRD-OR-15 | The STC PRD shall have an operational availability (Ao) of T/O. |
| Amplifying Information: Ao = Mean uptime/(mean uptime + mean downtime). Uptime is defined as the amount of time that the PRD is operating or capable of operating. Downtime is defined as the amount of time that the PRD is not capable of being operated for any reason, such as breakage, being out for repair, or the logistics associated with the repair. | ≥ 98% | ≥ 99.5% |
| PRD-OR-16 | The STC PRD shall have both T/O low battery indicators. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 5.13, the batteries that are used shall be widely available, shall not be unique to the PRD, and shall be replaceable in the field with tools that are easily obtained or are commercially available (e.g., screwdriver, coin). | Visible and audible | Same as Threshold |
| PRD-OR-17 | The STC PRD batteries shall be capable of powering the PRD in a non-alarm state for T/O. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 5.13, the batteries that are used shall be widely available, shall not be unique to the PRD, and shall be replaceable in the field with tools that are easily obtained or are commercially available (e.g., screwdriver, coin). | ≥ 24 hours | ≥ 168 hours |
| PRD-OR-18 | The STC PRD batteries shall be capable of powering the PRD’s audible, visual, and vibration alarms for T/O while continuously alarming. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 5.13, the batteries that are used shall be widely available, shall not be unique to the PRD, and shall be replaceable in the field with tools that are easily obtained or are commercially available (e.g., screwdriver, coin). | ≥ 30 min | ≥ 60 min |
| PRD-OR-19 | The STC PRD shall have a mean time between failure of T/O. |
| Amplifying Information: A failure is a severe degradation or total loss of a mission essential function. Mission essential functions may include detecting, analyzing, alarming, displaying, and communicating. The MTBF threshold of 43,800 hours equates to 1,825 days or 5 years. | ≥ 43,800 hrs | ≥ 87,600 hrs |
| PRD-OR-20 | The STC PRD shall operate as intended over the T/O range of relative humidity (RH) |
| Amplifying Information: IAW ANSI N42.32 2016, Section 7.3, the temperature at which testing is performed shall be 35 °C (± 2 °C). No alarms or spurious indications shall occur due to the changes in humidity. | 40% to 93% | 25% to 99% |
| PRD-OR-21 | The STC PRD shall operate as intended at temperatures from –20 °C (-4 °F) to +50 °C (122 °F). |
| Amplifying Information: IAW ANSI N42.32 2016, Section 7.1, if the manufacturer specifies a narrower operating temperature range, testing shall not be performed, and the PRD fails the test. If the manufacturer specifies a broader operating range, the instrument shall be tested at the broader temperature range specified by the manufacturer. Relative humidity shall be less than 75%. | The PRD response is acceptable if no alarms or spurious indications occur due to temperature changes, the PRD continues to alarm when exposed to the test source at all temperatures, and the display is readable at all temperatures. | The PRD response is acceptable if it meets the Threshold and the post-test measurements are within the values described in ANSI N42.32 2016, Section 4.8. |
| PRD-OR-22 | The STC PRD shall be able to operate as intended when switched on at the low temperature limit of -20 °C and at the high temperature limit of 50 °C within T/O. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 7.5, if the manufacturer specifies a narrower operating temperature range, testing shall not be performed, and the PRD fails the test. | 5 min | 2 min |
| PRD-OR-23 | The STC PRD shall withstand exposure to random vibrations at T/O spectral density at frequencies associated with the operation of body-worn equipment. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 9.1, the frequency endpoints associated with the operation of body-worn equipment are 5 Hz and 500 Hz. The physical condition and functionality of the PRD shall not be affected by the vibration (e.g., solder joints shall hold, nuts and bolts shall not come loose). No alarms or spurious indications shall occur as a result of the vibrations alone. | 0.01 g2/Hz | Same as Threshold |
| PRD-OR-24 | The STC PRD shall have a MTAT of T/O. |
Amplifying Information: The STC PRD shall operate without the need for scheduled maintenance. Scheduled maintenance includes any maintenance of the PRD except for:
• Charging and changing of batteries.
• Non-invasive cleaning.
• System operational checks (these functions shall require no special training or tools).
The formula for MTAT is: MTAT = (MTTR + Waiting Time) where:
• MTTR – the actual time a technician spends repairing the device.
| • Waiting Time – any time the device spends in a queue or idle state as the manufacturer awaits spare parts, ships the device to another repair facility, finds time to repair the device, spends time conducting a quality control review of the device, etc. | ≤ 30 days | ≤ 20 days |
| PRD-OR-25 | The STC PRD case design shall meet the requirements stated for ingress protection (IP) code T/O. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 7.4, IP53 refers to protection from the ingress of dust and spraying water. For IP53, the ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the PRD or to impair safety, and water sprayed at all six surfaces of the PRD shall have no harmful effects. | IP53 | IP67 |
| PRD-OR-26 | The STC PRD shall not be affected by exposure to electrostatic discharges at voltages of up to T/O. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 8.1, the method of testing shall be the contact discharge technique. When exposed to these electrostatic discharges, the PRD shall function correctly. No alarms or spurious indications shall occur as a result of the electrostatic discharges alone. | ± 6 kV | Same as Threshold |
| PRD-OR-27 | The STC PRD shall not be affected by radio-frequency (RF) fields over the frequency range of 80 MHz to 2.5 GHz at an intensity of T/O. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 8.2, when exposed to these RF fields, the PRD shall function correctly. No alarms or spurious indications shall occur as a result of the RF radiation alone. | 40 V/m | 50 V/m |
| PRD-OR-28 | The STC PRD shall operate as intended when exposed to a T/O magnetic field in all three mutually orthogonal orientations. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 8.3, no alarms or spurious indications shall occur as a result of the magnetic field alone. The gauss is a unit of measurement of magnetic induction, also known as magnetic flux density and essentially refers to the intensity of a magnetic field. Amperes per meter (A/m) is an indication of the magnetic field strength. | 100 A/m (1.3 gauss) 60 Hz AC | 100 A/m (10 gauss) 60 Hz AC |
| PRD-OR-29 | The STC PRD shall be fully operational within T/O of exposure to rapid temperature changes. |
Amplifying Information: IAW ANSI N42.32 2016, Section 7.2, the rapid temperature changes shall be from 22 °C to –20 °C, –20 °C to 22 °C, 22 °C to 50 °C, and 50 °C to 22 °C with each change being made in less than five minutes. If the manufacturer specifies a narrower operating temperature range, testing shall not be performed, and the PRD fails the test.
| See FR-06 | 2 min | 1 min |
| PRD-OR-30 | The STC PRD shall alarm as intended after being subjected to drops on each of its six surfaces from a height of T/O onto a concrete floor. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 9.2, there shall be no visible external damage to the PRD, except for minor scratches or nicks on the case, and all control functions shall be verified to be operating correctly. | 1.5m (≈ 5ft) | 2.44m (≈ 8ft) |
| PRD-OR-31 | The STC PRD response shall be unaffected by T/O impacts, such as those that may occur from low intensity impacts from sharp contact with hard surfaces. |
| Amplifying Information: IAW ANSI N42.32 2016, Section 9.3, the objective of this test is to ensure the PRD’s response shall be unaffected by from low intensity impacts from sharp contact with hard surfaces. The test shall be performed on each side of the PRD case, and there shall be three impacts on each side of the PRD. The 0.2 J impact is equivalent to a mass of 0.2 kg moving at 1.4 m/s over a distance of 0.1m. The performance is acceptable if no alarms or spurious indications occur as a result of the impacts alone. | 0.2 Joules |
| (≈ 0.15 ft/lbs) | 0.27 Joules |
(≈ 0.2 ft/lbs) PRD-OR-32 The STC PRD shall be provided with PC supporting software that runs on a T/O operating system.
Amplifying Information: The intent of the vendor-provided software is to perform software updates, configuration changes, calibrations, and some level of troubleshooting.
| See FR-07, FR-08, and FR-09 | Windows 10 or newer | Same as Threshold |
| PRD-OR-33 | The STC PRD shall demonstrate cyber resilience such that the PRD will continue to perform designed T/O operations throughout all incidents. |
Amplifying Information: Reference DHS Policy Directive Number: 4300A, V13.3 2023, Information Technology System Security Program, Sensitive Systems. Upon re-establishment of communications following any communication failures, the PRD shall transmit all information collected during the time frame of the communications failure.
| See FR-10, FR-11, and FR-12 | R/N detection | R/N detection, including the ability to transfer data |
| PRD-OR-34 |
KPP-4 The STC PRD shall have dimensions of T/O.
| Amplifying Information: These dimensions exclude any holster or carrying case. Length is 20cm, width is 10cm, and height or thickness is 5cm. | ≤ 12 cm x 8 cm x 4 cm | ≤ 10 cm x 6.5 cm x 3.5 cm | Requires 3rd party independent testing at a minimum to substantiate claim of “meets.” |
| PRD-OR-35 |
KPP-5 The STC PRD shall have a maximum mass of T/O.
| Amplifying Information: IAW ANSI N42.32 2016, Section 5.3. The PRD as it is worn during use, including the battery and holster or clip, shall be weighed. | ≤ 400g (≈ 0.88lbs) | ≤ 240g (≈ 0.53lbs) | Requires 3rd party independent testing at a minimum to substantiate claim of “meets.” |
| PRD-OR-36 | Powering off the STC PRD shall require either T/O. |
| Amplifying Information: None | (1) A two-step process - or - |
| (2) A sustained hold of the power button for a minimum of 10 seconds | (1) A two-step process - or - |
(2) A sustained hold of the power button for a minimum of 5 seconds PRD-OR-37 The STC PRD shall physically accommodate the 5th to 95th percentile of operators when conducting T/O activities.
| Amplifying Information: The STC PRD must physically accommodate the majority of operators and minimize the potential for fatigue or injury over the course of short- and long-term use. Fifth to 95th was based on MIL-STD-1472H. Per this standard, “the multivariate central 90 percent of suitably clothed and equipped males of the target user population and the multivariate central 90 percent of suitably clothed and equipped females of the target user population will be able to use and fit the system to accomplish required physical tasks under consideration. The distribution of the 10 percent not accommodated by the design, including range of adjustment of system features, should be evenly split between the smaller and larger portions of the population.” | Primary screening and routine maintenance | Same as Threshold |
| PRD-OR-38 | The STC PRD shall provide a unique visible, audible, and vibration notification to the operator when the dose rate/exposure rate exceeds T/O. |
| Amplifying Information: Exposure rate is a measure of the amount of radiation present in the environment and is usually expressed in units such as milliRoentgens per hour (mR/h). Dose rate is a measure of the amount of radiation that is absorbed by a person (or object) and is usually expressed in units such as millirems per hour (mrem/h). In reality, for gamma rays there is approximately a one-to-one ratio between exposure rate and dose rate. While not a requirement, the preferred unit of measurement is (mR/h). | 2 mR/h | An operator adjustable dose rate setting | |
| PRD-OR-39 | Amplifying Information: IAW ANSI N42.32 2016, Section 8.4 and as described in the FCC/CFR15.109 rules for unintentional radiators Class A digital devices. | Emission frequency Field strength range (MHz) (microvolts/meter) |
30–88 100 88–216 150 216–960 200
| Above 960 500 | Same as Threshold | |
| PRD-OR-40 | The STC PRD shall have the capability to connect with and transmit data to T/O devices. |
Amplifying Information: At a minimum, the desired connection between the PRD and smart phone/tablet shall be made via Bluetooth. Smart phones and tablets using
• Android 12 and higher - and -
| • iOS 16 and higher | Same as Threshold |
| PRD-OR-41 |
KPP-06 The STC PRD shall be capable of transmitting data containing the T/O information.
Amplifying Information: IAW ANSI N42.32 2016, Section 5.14, the data format shall meet the ANSI N42.42 requirements. The transfer protocol shall be fully described in the manufacturer’s technical manual. No data shall be lost due to changing or recharging batteries. • Manufacturer name
• Instrument model
• Serial number
• Software version
• Gamma detector type (e.g., CsI(Tl), NaI(Tl), GMT)
• Date and time of measurement
• Measured radiation levels (e.g., exposure rate, dose rate, or level)
| • Gamma-ray alarm indication | Same as Threshold with the additional data field of “operating hours” | Requires 3rd party independent testing at a minimum to substantiate claim of “meets.” | |||||
| Functional Requirements | |||||||
| FR# | OR# | Functional Requirement | Threshold | Objective | Clarification | Meets or Does Not Meet |
| Reference/ Explanation | Available Test Data | ||
| PRD-FR-01 | PRD-OR-02 | The STC PRD shall demonstrate the Probability of Detection (Pd) listed in PRD OR-02 when exposed for T/O. |
| Amplifying Information: In this context, the probability of detection (Pd) is a statistical measure of the likelihood that the sensor (PRD) clearly detects the presence of ionizing radiation it is intended to monitor for. Include multiple points for Pd assessment. Test data should provide context to the results in case one or more devices do not meet this requirement. | Up to 30 seconds (dwell time) to Co57 shielded by 5 millimeters of steel producing 2.33 (± 10%) 122 kilo electron volts (keV) photons/cm2- second and separately to Ba-133 shielded by 5mm of steel producing 1.44 (± 10%) 356 keV photons/cm2-second based on a background radiation level of 7.5 μR/hr. | Same as Threshold | |
| PRD-FR-02 | PRD-OR-03 | The STC PRD shall have an audible alarm with a T/O. |
N42.32, 2016 Section 5.10.1., the audible alarm of the PRD shall be activated with the appropriate radiation sources (137Cs) and the A-weighted sound level measured at a distance of 30 cm from the source. Test data should provide context to the results in case one or more devices do not meet this requirement.
| Note: Volumes of approximately 50 dB are generally considered pleasant for human hearing; however, may not be loud enough for an operator to hear over ambient noise levels. Volumes above 70 dB over a prolonged period of time may damage a person’s hearing. Discomfort levels start around 100 dB and volumes above 120 dB can cause immediate harm to a human being’s hearing. | A-weighted sound level between 70 dB(A) and 100 dB(A) | A-weighted sound level between 85 dB(A) and 100 dB(A) | |
| PRD-FR-03 | PRD-OR-03 | The STC PRD audible alarm shall have a frequency within the range of T/O. |
| Amplifying Information: IAW ANSI N42.32, 2016 Section 5.10.1., the audible alarm of the PRD shall be activated with the appropriate radiation sources (137Cs) and the frequency measured at a distance of 30 cm from the source. Test data should provide context to the results in case one or more devices do not meet this requirement. | 1000 Hz to 4000 Hz. | Same as Threshold | |
| PRD-FR-04 | PRD-OR-07 | The STC PRD shall alarm in ≤2 s after exposure to an increase in the background radiation level of 50 μR/h above background while moving at a speed of T/O. |
| Amplifying Information: IAW ANSI N42.32, 2016, Section 6.2, the PRD shall alarm in ≤2 s after exposure to an increase in the ambient radiation level of 50 μR/h above background for 241Am, 137Cs and 60Co sources when moving at a speed of 1.2 m/s at a distance of closest approach of 1.5 m. | 0.6 m/s (+/-10 %) | 1.2 m/s (+/-10 %) | |
| PRD-FR-05 | PRD-OR-09 | The STC PRD Time to Alarm threshold (OR-06) shall not be affected by slowly increasing radiation levels when approaching a radiation source at a speed of T/O. |
| Amplifying Information: IAW ANSI N42.32, 2016, Section 6.4 (gamma only), the 137Cs source shall produce an exposure rate of 50 μR/h (± 20%) above background at the reference point of the PRD at the distance of closest approach of 1.5 m. | ≤0.5 m/s | Same as Threshold | |
| PRD-FR-06 | PRD-OR-29 | The STC PRD shall operate as intended when exposed to rapid temperature changes within T/O. |
Amplifying Information: IAW ANSI N42.32, 2016, Section 7.2, each temperature change shall be made in less than 5 minutes. The temperature ranges are:
• (22 °C to –20 °C),
• (–20 °C to 22 °C),
• (22 °C to 50 °C), and
| • (50 °C to 22 °C) | 60 minutes | 30 minutes | |
| PRD-FR-07 | PRD-OR-32 | The STC PRD shall require T/O software updates to be authenticated. |
Amplifying Information:
• Applicable in all cases where the device requires updates to be made by CWMD.
• Software updates can use certificates to validate the authenticity of the update.
| • The vendor shall provide design documentation that describes the operation of the authentication features. | All | Same as Threshold | |
| PRD-FR-08 | PRD-OR-32 | The STC PRD shall require all changes made to the device detection settings to be authenticated T/O. |
Amplifying Information:
• Changes to detection settings should not be permitted without authentication either by group or individual user.
• A group authenticator shall be considered a single authenticator (e.g., password, passcode) used per device. An individual authenticator shall be considered a discrete authenticator (e.g., personal identification number [PIN]) per individual user, normally associated with a user identifier.
| • Authentication may be made at the PRD level or as part of the setup software. | Group authentication | Individual authentication | |
| PRD-FR-09 | PRD-OR-32 | The supporting software shall collect T/O audit information of all changes made to PRD software and detection settings. |
Amplifying Information: None a. What type of event occurred.
b. When the event occurred.
c. Where the event occurred.
d. Source of the event;
e. Outcome of the event.
f. Identity of any individuals, subjects, or objects/entities associated with the event.
Audit information shall be protected from changes (to include deletion) by all users.
| Same as Threshold | ||
| PRD-FR-10 | PRD-OR-33 | The PRD shall provide a T/O alert to the operator of any communication anomalies that prevents data from being transmitted from the PRD to the mobile device. |
| Amplifying Information: Any alerts should be clear to the operator that they are in response to communication issues. | Audible and visual | Same as Threshold | |
| PRD-FR-11 | PRD-OR-33 | The PRD shall continue to T/O regardless of the state of the communications interface (BT). |
| Amplifying Information: None | Detect and alarm | Same as Threshold | |
| PRD-FR-12 | PRD-OR-33 | The PRD shall allow an operator to reset device to manufacturer’s known good state. |
Amplifying Information: Manufacturer’s known good state (factory default settings) shall be protected and not modifiable and shall be checked whenever the PRD is started. Yes/No (Pass/Fail) Same as Threshold