Attachment 1 Statement of Work Part A Rm 17.pdf
PDF 3 MB Posted
- Solicitation number
- 12905B24Q0143
About this file
This document is a Statement of Work (SOW) for the Forage and Range Remodel, Room 017 project at the USDA, ARS - FRR building greenhouse in Logan, UT. The SOW outlines the scope of work, which includes removing existing cabinetry, preparing and painting the walls, laying new VCT tile flooring, installing new electrical outlets and light switches, and installing new steel casework and countertops. The contractor will be responsible for all labor, materials, and disposal of debris. The SOW provides detailed requirements for the project, including part numbers and specifications for the cabinets, countertops, and other materials to be used.
The related federal contract opportunity is a Solicitation for Room Renovations for USDA ARS in Logan, UT, with an estimated magnitude between $100,000 and $250,000. The solicitation requires the contractor to provide all labor, materials, equipment, supplies, supervision, and transportation needed to renovate Rooms 17, 121, and 122 at the USDA ARS facility in Logan, UT. The work is to be performed in accordance with the SOW and other attachments, and the completion time is 120 days after the Notice to Proceed. The applicable Department of Labor General Decision is UT20240082 dated 1/5/2024.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
United States Department of Agriculture Agricultural Research Service
STATEMENT OF WORK
Forage and Range Remodel, Room 017
Forage and Range Research Laboratory 690 North 1100 East, USU Campus Logan, UT 84322-6300
DATE: 04/26/2024
STATEMENT OF WORK
TABLE OF CONTENTS
1.0 Project Information
2.0 Project Contact Persons
3.0 Scope of Work
4.0 Project Requirement Details
5.0 Map
1.0 Project Information:
A. Project Number: 1129650
Project Title: Forage and Range Remodel, Rooms 017 and 018
B. Project Location: USDA, ARS - FRR building greenhouse
690 North 1100 East Utah State University Logan, UT 84332-6300
2.0 Project Contact Persons:
A. CONTRACTING OFFICER (CO): Michael Sherlock
Email: Michael.Sherlock@usda.gov
B. RESEARCH PROGRAM REPRESENTATIVES (RPR): Ramsey Buffham
Email: Ramsey Buffham@usda.gov
C. LOCATION ADMINISTRATIVE OFFICER (LAO):
TBD
D. Location Coordinator
TBD
mailto:Buffham@usda.gov
3.0 Scope of Work:
The Contractor shall provide all professional services necessary for the accomplishment of each project and such required services shall be in accordance with requirements as described herein.
Background: There is one laboratory in need of remodeling in this phase.
The general overview is that the lab has some existing cabinetwork that will need to be removed, the floors will need cleaned, prepared and re-tiled, the walls prepared and painted, plumbing and electrical dealt with, and then new steel case cabinets and counter tops installed.
All diagrams and part numbers for steel casework are from Formaspace, 1100 East Howard Lane, #400, Austin, TX 78753. Counter tops will be epoxy. Cabinets, countertops, and plumbing fixtures are supplied by the FRRL. Cabinets may come from a different source; these numbers and drawings are for reference purposes only.
4.0 Project Requirement Details Room 017
1. Remove existing casework, sink and cabinets. Retain wall mounted dish drying rack for re-use. Cap utilities as required. Coordinate any water, air, and electrical outages with FRR staff. Retain and reinstall drying rack over the new sink.
2. The contractor will be responsible for removal and disposal of all cabinets and construction debris.
3. Frame in the door connecting to room 016, cover with sheetrock, and prepare for painting.
4. Prepare, patch, prime and paint the walls, use PPG Manor Hall 82-3510 interior semi-gloss paint color NB1 NG6, NL5 for the topcoat.
5. Level the floor and prepare as needed for the installation of casework on the south wall.
6. Clean and prepare the floor, lay VCT tile over the floor.
The floor is currently polished cement with a varnish type sealant on it, that is coming up in a few areas. Use Armstrong 51858031 Sandrift White tile, 12”x12”x1/8”
7. Protect the tile with 2 coats of Armstrong S-495 Commercial Floor Sealer.
Follow this with three coats of Armstrong S-480 Commercial Floor Polish, spray buffing after the last coat per instructions at the end of this packet.
8. Install 4” black rubber base around all walls and cabinet work.
9. Install new light switches Leviton Model# R52-01221-20W or equal, and receptacles, white 20-amp industrial grade Leviton Model #R72-05352- 0WS, or equivalent in existing outlets, excluding the 220v outlet on the east wall. Use white colored outlets and switches.
10. Replace the GFI outlet near the sink with a new GFI outlet.
11. Install drain lines and plumbing for benches on the south wall.
12. Install new casework per drawings and specs provided. On two walls the casework will be held out 6” from the wall to accommodate plumbing and electrical. Cabinet top will cover this space.
13. Install an on-demand water heater under the sink on the south wall under the 24” sink base. This water heater shall feed the faucet on the south wall, not the main sink. The water heater will be provided by the FRRL.
14. Provide electrical for this water heater, placed in the bottom of the sink cabinet. 208v 40 amp
15. Install small sink/drain in cabinet top. Example below, near backsplash in the 24” sink base. The faucet will be the pot filler detailed below.
16.
17. Install commercial grade pot filler with flexible hose and vacuum breaker or backflow prevention on the south wall in the casework close to the back by the small sink in the sink base. Faucet provided by FRRL.
18. Install warning sign on wall behind faucet on south wall warning about hot water.
19. Install five (5) 20-amp receptacles on the south wall per the diagram, and one outlet on the east alcove wall per the diagram, all GFI protected.
These outlets must each be on their own 20-amp circuits.
20. Install tank support for the DI water tanks and reinstall the DI water supply system on the right of the main sink.
21. Re-install dish drying rack on the wall, and new paper towel and soap dispensers which shall be provided by the FRRL.
Outlet details room 017 south and east walls.
-4 GFI on their own 20 amp circuits south wall.
-two duplex receptacles, may be same circuit, north and northwest walls -replace the GFI to the right of the sink on the west wall -add a combo GFI/duplex on the east wall all GFI protected
5.0 Map
S-495 Commercial Floor Sealer "Product Information" Data Sheet / Product Spec Sheet for S-495 Commercial Floor Sealer
Sep 9, 2021•Knowledge
PRODUCT ATTRIBUTES
Use: Commercial
Use For:
Commercial resilient flooring Asphalt tile
Color: Milky, dries clear
Spread Rate: 1,500 to 2,000 square feet per gallon per coat
• Stain resistant sealer for porous or well-worn floor surfaces
• Water-based acrylic emulsion
• Provides an excellent base for S-480 Commercial Floor Polish or other commercial floor polishes
• 16% solids for easy application and excellent leveling
• Semi-permanent for resistance to conventional polish stripping
• High durability for long lasting protection
• pH of 7.8 One year
Shelf Life: One year if not opened. Keep from freezing
Available Units: Gallon - 4 gal/ctn; 5 Gallon
VOC: 0.0% per CARB Rules
STORAGE: Keep from freezing.
MSDS
Refer to the Safety Data Sheet for additional product information.
ORDER & WAREHOUSE INFORMATION
Language English/Spanish Size 1 gallon
5 gallons Item No. 1 gallon - 00495408
5 gallons - 00495508
Item UPC 1 gallon - 042369925273 (ctn)
042369165198 (bottle) 5 gallons - 042369065207
Carton Dimensions
1 gallon - 16"L x 11"W x 14"H 5 gallons - 12.5"L x 12.5"W x
14.75"H Carton Weight 1 gallon - 36.58 lbs
5 gallons - 45.39 https://armstrongflooringpartner.force.com/ArmstrongConnect/s/article/S-480-Commercial-Floor-Polish-Product-Information https://armstrongflooring.my.site.com/ArmstrongConnect/s/article/S-495-Commercial-Floor-Sealer-MSDS?r=318&ui-knowledge-components-aura-actions.KnowledgeArticleVersionCreateDraftFromOnlineAction.createDraftFromOnlineArticle=1
Items per Carton 1 gallon - 4
5 gallons - Containers sold individually
Cartons per Pallet 1 gallon - 40 5 gallons - 36
DIRECTIONS FOR USE
FLOOR PREP:
• Sweep or vacuum thoroughly
• Mop or scrub the floor with properly diluted S-485 Commercial Floor Cleaner
• Rinse carefully, if needed
• Let floor dry
SEAL AND POLISH:
• Apply 1 to 2 coats
• Pour sealer into a clean bucket (never pour sealer directly onto floor)
• Use a clean finish mop (rayon) or finish applicator
• Let dry 60 minutes between coats and before applying polish
• Apply 3 to 5 coats of S-480 Armstrong Commercial Floor Polish
STRIP:
• Strip using a commercial floor stripper, following label directions
• Scrub with a 3M blue pad, scrub brush or equal
PRODUCT IMAGE
https://armstrongflooringpartner.force.com/ArmstrongConnect/s/article/S-485-Commercial-Floor-Cleaner-Product-Information https://armstrongflooringpartner.force.com/ArmstrongConnect/s/article/S-480-Commercial-Floor-Polish-Product-Information
S-480 Commercial Floor Polish "Product Information" Data Sheet / Product Spec Sheet for S-480 Commercial Floor Polish
Jan 16, 2021•Knowledge
PRODUCT ATTRIBUTES
Use: Commercial Use For:
All Armstrong commercial vinyl floor coverings except Excelon SDT Asphalt and rubber tile Linoleum Ceramic - although not of much value on glazed ceramic Slate and terrazzo although other products are designed for better results
Do Not Use For: Wood and marble
Color: Milky, dries clear
Spread Rate: 1,500 to 2,000 square feet/gallon/coat depending on surface characteristics of the floor
• High durability for long-lasting protection.
• Metal cross-linked acrylic copolymer emulsion polish.
• 18% solids for easy application and excellent leveling.
• Dries bright for areas where buffing is not applicable or desired.
• Excellent buffing response for spray-buffing repairs or high-speed burnishing programs (up to 2,000 rpm).
• Readily strippable.
• Meets the ASTM D2047 standard for slip resistance on dry floors.
• pH of 8.5 - 8.75.
Shelf Life: One year if not opened. Keep from freezing.
Available Units: Gallon - 4 gal/ctn; 5 Gallon
VOC: VOC Content: 0%; as required by California General Consumer Products Rule, California Code of Regulations
STORAGE: Keep from freezing.
MSDS
Refer to the Material Safety Data Sheet for additional product information.
ORDER & WAREHOUSE INFORMATION
Language English/Spanish English/French
Size 1 gallon 5 gallons
1 gallon (3.78L) 5 gallons (18.9L)
Item No. 1 gallon - 00480408 5 gallons - 00480508
1 gallon - S-480601 5 gallons - S-480603
Item UPC 1 gallon - 042369059503 (ctn)
042369159500 (bottle) 5 gallons - 042369059534
1 gallon - 10042369159866 (ctn) 042369159869 (bottle)
5 gallons - NA https://armstrongflooring.my.site.com/ArmstrongConnect/s/article/S-480-Commercial-Floor-Polish-MSDS
Carton Dimensions
1 gallon - 16"L x 11"W x 14"H 5 gallons - 12.5"L x 12.5"W x
14.75"H
1 gallon - 16"L x 11"W x 14"H 5 gallons - 12.5"L x 12.5"W x
14.75"H
Carton Weight 1 gallon - 37.09 lbs 5 gallons - 45.56
1 gallon - 37.09 lbs (16.3 kg/ctn) 5 gallons - 45.5 (21.3 kg)
Items per Carton 1 gallon - 4
5 gallons - Containers sold individually
1 gallon - 4 5 gallons - Containers sold individually Cartons per Pallet
1 gallon - 40 5 gallons - 36
1 gallon - 40 5 gallons - 36
DIRECTIONS FOR USE
FLOOR PREP:
Sweep or vacuum thoroughly Wash with S-485 Armstrong Floor Cleaner Rinse thoroughly Let floor dry
POLISH - LOW TRAFFIC:
Apply 3 to 5 coats (do not apply more than four coats of polish at one time; wait a minimum of 24 hours before applying more polish) Pour polish into a clean bucket (never pour polish directly onto floor) Use a clean finish mop (rayon) or finish applicator Let dry 30 minutes between coats
POLISH - HIGH TRAFFIC:
Follow instructions above for Low Traffic; then High speed burnish
OR
Spray buff (spray-buff solution one part S-480 to two parts water)
OR
Apply 1 or 2 extra coats
Water heater details:
CHRONOMITE LABS Electric Tankless Water Heater: Indoor, 6,240 W, 2 gpm Max. Flow Rate
Item 10G725
Mfr. Model
SR-30/208 HTR-I
Product Details Catalog Page
Brand
CHRONOMITE LABS
Manufacturer Part Number
SR-30/208 HTR-I
Current
30 A https://www.grainger.com/content/general-catalog?pagelabel=2713&search=10G725
Operating Voltage
208V AC
Minimum Flow Activation
0.65 gpm
Adjustable Thermostat No
Environment Indoor
Mounting Orientation Horizontal
Maximum Delivered Temperature 160 °F
Cold Inlet Size 3/8 in
Hot Outlet Size 3/8 in
Overall Depth
2.75 in
Overall Height
6.25 in
Overall Width
9.63 in
Power Consumption 6,240 W
Standards ADA Compliant; cETLus Listed; CSA Certified; IAPMO; UL Listed; UPC
Temperature Rise @ Flow 28°F @ 1.50 gpm; 34°F @ 1.25 gpm; 43°F @ 1 gpm
Maximum Water Pressure 80 psi
Market Commercial; Residential
Application Bar Sinks; Kitchen; Lavatory; Residential; Scrub Sinks; Service Sinks; Showers
Maximum Flow Rate 2 gpm
Housing Material Aluminum
Phase Single
Minimum Delivered Temperature 140 °F
Hot Outlet Type Compression
Cold Inlet Type Compression
Element Material Celcon Plastic
Minimum Water Pressure 25 psi
Includes Compression Fittings; Faucet Flow Control
Mounting Type Wall Mounting
Cord Conductor Gauge 10 AWG Wire
UNSPSC
40101825
Country of Origin Mexico (subject to change)
| United States Department of Agriculture |
| Agricultural Research Service |
| S-495 Commercial Floor Sealer "Product Information" |
| Data Sheet / Product Spec Sheet for S-495 Commercial Floor Sealer |
| Sep 9, 2021•Knowledge |
| S-480 Commercial Floor Polish "Product Information" |
| Data Sheet / Product Spec Sheet for S-480 Commercial Floor Polish |
| Jan 16, 2021•Knowledge |
| CHRONOMITE LABS Electric Tankless Water Heater: Indoor, 6,240 W, 2 gpm Max. Flow Rate |
| Product Details |
File details come from the government source that posted it. Updated .