This document outlines the requirements for twenty-two fume extractors to be provided to the Anniston Army Depot. The extractors must meet specific technical requirements including a minimum air flow of 900 cubic feet per minute, MERV rating of 15, 460 volt 3 phase power supply, and dimensions of 43 by 48 by 36 inches. Equivalent products must include the specified filter and have a minimum 10-inch diameter and 12-foot long extraction arm. The contractor shall provide both digital and hard copy technical manuals for operations, maintenance, schematics, parts lists, troubleshooting, and other applicable technical data in English. The related federal contract opportunity is solicitation number W911KF-23-Q-0034 from the Department of the Army Materiel Command Contracting Command Detroit Arsenal to procure these 22 fume extractors for use at the Anniston Army Depot.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fume Extractor Requirement

1.0 Salient Characteristics: The government has a requirement for twenty-two (22) Miller FILTAIR Capture 5 fume extractors, part number 951575, or an equivalent product. These items are required to meet standards for three separate welding locations on Anniston Army Depot (ANAD). The following are the salient characteristics that must be met for another extractor to be considered an equivalent:

· Filter included

· Air Flow shall be 900 Cubic Feet Per Minute (CFM) minimum

· Minimum Efficiency Reporting Value (MERV) Rating – 15

· Input Voltage – 460 volts / 3 Phase / 60 Hertz / 3.7 Amps

· Motor Horsepower shall be no less than three horsepower

· Maximum Sound Level – 77 dBA

· Shall use Miller FILTAIR Capture 5 FilTek XL Replacement Filter 301106

· Minimum Ten-inch diameter extraction arm

· Minimum Twelve-feet long extraction arm

· Automatic Cleaning Filter

· Shall fit within envelop as follows Height 43 inches, Depth 48 inches, Width 36 inches

2.0 Technical Manuals: The contractor shall provide three (3) hardcopy and one (1) digital copy of the commercial-off-the-shelf (COTS) manuals for operations and maintenance. These manuals shall include electrical, hydraulic, and pneumatic schematics, as applicable; parts lists, troubleshooting procedures, preventive maintenance requirements, lubrication schedules, calibration procedures, etc. In addition, any other technical data normally furnished with the equipment shall be provided in digital as well as a hard copy. All technical data shall be furnished in the English language.