This statement of work outlines requirements for a federal contract to provide security camera systems for four dormitory buildings at Fairchild Air Force Base. The contractor shall furnish PELCO brand security cameras, a VideoXpert video management system, storage servers, licenses, cabling and installation services. Specific requirements include supplying 58 exterior and interior cameras for Building 1250, 21 cameras for Building 2257, 21 cameras for Building 2259 and 9 cameras for Building 2266. The contractor must install all equipment, configure the video management system, provide training and warranties, and ensure the systems meet technical specifications for camera coverage, recording capabilities and network integration outlined in the appendixes. The statement of work establishes quality standards, labeling conventions, installation timelines and acceptance criteria that must be followed to complete the contract.

View the file

Other files

File Type Posted
Amendment 002.pdf PDF
Attachment 1 FA462022QA145 REV 2.pdf PDF
Amendment 00001.pdf PDF
JA_Redacted.pdf PDF
FA462022QA145.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK

FY22 DORM CAMERA SYSTEMS

Buildings 1250, 2257, 2259, 2266

FAIRCHILD AFB, WA

July 2022

FA462022QA145

Attachment 1 Statement of Work

1. DESCRIPTION OF SERVICES

The Contractor shall provide a Certified VideoXpert Video Management System, BRAND NAME PELCO Security Cameras, and Surveillance system to purchase and install a combination of fixed; Pan, Tilt, Zoom (PTZ); Internet Protocol (IP); and Power over Ethernet (POE) cameras from the respective areas to the building’s switches. Additionally, provide PELCO 144TB Storage in accordance with (IAW) building specific appendixes. These cameras shall be integrated onto the existing PELCO VideoXpert system; all components shall be VideoXpert compatible. The Contractor shall perform IAW all federal, state, and local laws and regulations as well as manufacturer’s recommendations and specifications, operator and maintenance manuals, and this Statement of Work (SOW).

1.1 Scope of Work

1.1.1 Exterior Camera(s) (Depicted as “E”)

Will be an outdoor color viewing capable contained in an environmental housing with a heater.

1.1.1.1 Exterior Cameras will have PTZ, POE infrared minimum of 150 meters, low-light performance, auto-focusing, video encoding H.264/H.265, frame rate up to 30 frames, 20X optical zoom, 12X digital zoom, aspect ratio 16:9, and be 4K. Minimum resolution 3840 x 2160.

Web interface requires Firefox, Google Chrome, or Edge for accessing cameras.

1.1.1.2 Stairwell Cameras will be fixed and contained in an environmental enclosure with a heater. Cameras shall be color viewing and dome lensed with covers obscuring camera directions. Cameras shall have auto-focus, infrared minimum of 50 feet, low-light performance, day and night, video encoding H.264/H.265, POE, audio capability and frame rate up to 60 frames with a minimum resolution of 2592 x 1944. For web interface, accessing cameras must use Firefox, Chrome, or Edge.

1.1.2 Interior Fixed Cameras (Depicted as “I”)

Will be color viewing and dome lensed with covers obscuring camera directions. Cameras must have the capability of autofocus, infrared minimum of 50 feet, low-light performance, day and night, video encoding H.264/H.265, POE, audio capability, and frame rate up to 60 frames with a minimum resolution of 2592 x 1944. For web interface, accessing cameras must use Firefox, Chrome, or Edge.

1.1.3 Government Furnished Equipment (GFE)

Communication switches will be available in each building as required. Switches will have available copper RJ-45 ports, 1 gbps, POE+ (802.3at, with backwards compatibility to 802.3af), 370W of available POE power. Switches provided will be Juniper, with single Power Supply Unit (PSU). No additional cybersecurity required by the Contractor. The 92 CS/SCOI is responsible for programming all GFE switches.

1.1.4 Contractor Equipment

The Contractor shall provide ladder(s), lift or other means for elevation accessing high points regarding cameras, boxes, conduit, etc. The Contractor shall provide all tools, equipment, and other specialized tools for installation. The Contractor is responsible for any and all damage caused from installing cameras, conduit, boxes, etc.

1.1.5 Cabling and Connection

1.1.5.1 All camera Ethernet runs will be CAT 6 and run between each respective camera and GFE switches. Splices are *NOT* permitted. Cables shall *NOT* lay on ceiling tiles. Cables may run in existing cable trays or affixed to sheetrock walls above ceiling. CAT 6 cables will terminate by American National Standards Institute (ANSI) Telecommunications Infrastructure Standard (TIA) / Electronic Industries Alliance (EIA) T568B Standard unless otherwise dictated by hardware specifications unless otherwise dictated by hardware specifications.

1.1.5.2 There will be no loose or poorly fitted connections.

1.1.5.3 Exterior camera connections will be in exterior waterproof enclosures.

1.1.5.4 Pull through enclosures can be used. Enclosures used for exterior purposes shall be weatherproof.

1.1.5.5. All cabling shall be neat, organized, labeled, and have relief loops (minimum 24 inches).

Cabling shall *NOT* be bent, crimped, or in any condition or shape which degrades signal quality.

1.1.5.6 Ethernet cable shall be PURPLE color.

1.1.5.7 There shall be *NO* exposed wires, cables, etc. Only exposed cables may reside in communication/electrical rooms.

1.1.5.8 Ethernet switch connections will be labeled in accordance with the building specific appendixes.

1.1.5.9 Each interior and exterior camera run will be identified in the building specific appendixes. Additionally, the optimal views, coverage areas, sample locations photos, and building specific equipment lists will be identified in each building specific appendix.

1.1.5.10 Above-ceiling exposed cabling will be a minimum of 3 feet from lighting and 120 VAC or higher from electrical boxes, sources, etc. Wires concealed within electrical or metallic tubing (EMT) can be within 3 feet of lighting and electrical sources.

1.1.5.11 New pathways through sheetrock will be sealed with fire caulk. If running wire through existing cable trays with a fire block, after cable is ran, ensure block is in its original configuration.

1.1.6 POE Injectors

POE Injectors are permitted for longer distances and when installed per manufacturer’s installation instructions. Injectors are required to be on an uninterrupted power supply (UPS), and shall not share the GFE switch UPS. NOTE: There will be *NO* electrical extension cords plugged into the UPS.

1.1.7 Camera Mounting

Cameras requiring mounting boxes will be supplied and affixed by the Contractor. When the walls consist of concrete, the mounting boxes may be used. Mounting boxes shall *NOT* be glued to concrete. Camera mounting devices must handle high winds in excess of 50 MPH.

Drilling into the building for the purpose of mounting cameras and running cable is authorized.

1.1.8 Conduit

There shall be *NO* exposed cabling. If conduit is required, it shall be EMT or liquid tight flex conduit. Conduit fittings shall be applicable fittings for each respectable conduit types. Conduit will be hidden where possible and will only be visible when other options are no longer acceptable. Exterior cameras may have exposed conduit. Other than flex, EMT attached to brick will be painted black, conduit attached to sheetrock shall be color matched to existing paint. All exterior conduit fittings shall have waterproof compression connectors.

1.1.9 Mounting hardware and face plates

PELCO mounting brackets and camera housings shall stay the original color.

1.1.10 UPS

As required by building specific appendixes, install Cyber Power 1000VA/750 W Model PR 1000LCDM1U or 92 CS/SCOI approved equivalent. UPS shall be co-located with switch. UPS shall be racked configured for a Tripp-Lite Model SRWF6U36. There shall be *NO* daisy-chain UPS with other UPS. On-site government UPS will *NOT* be used for this application. If POE injectors are used, UPS must maintain 30 minutes of battery backup power. UPS will have an external visible label affixed to the top stating purchase and battery test dates.

1.1.11 Lockable Rack

As required by building specific appendixes, install Tripp-Lite Model SRWF6U36 lockable racks. Racks shall *NOT* be mounted to sheetrock and shall be mounted on ¾ inch plywood color matched to the room. GFE switch and UPS will reside within the rack.

1.1.12 Electrical Outlets

If additional electrical outlets are required, the Contractor is responsible for providing the required electrical outlets and terminating within the electrical breaker panel. This installation shall be performed by a licensed electrician. The breaker shall be labeled for the corresponding cameras.

1.1.13 Camera Recordings

1.1.13.1 The Contractor is responsible for purchasing PELCO VXS2-T144-12, VideoXpert Storage Server, T-Series, RAID 6, 144TB, and necessary licenses IAW building specific appendixes. The Contractor shall install the Storage Manager and activate licenses(s) on a standalone off the commercial network VideoXpert system. Storage manager will be installed into a pre-existing tower rack which has adequate space, power, and an UPS. Installation of the storage manager shall be coordinated with 92 CS/SCOI.

1.1.13.2 The Contractor will add storage manager to VideoXpert Toolbox. Coordinate with 92 SFS/ESS. Upon successful storage manager integration, the contractor shall email 92 SFS/ESS all license, entitlement(s), and associated paperwork.

1.1.13.3 All cameras programmed and assigned to record shall be verified by 92 SFS/ESS. The storage manager and cameras provided shall *NOT* decrease the bandwidth or degrade video surveillance.

1.1.14 Camera Licenses

1.1.14.1 The Contractor shall purchase applicable licenses for cameras including an offline VideoXpert and as required a 144TB recording. The contractor is responsible for activating the licenses with VideoXpert Toolbox. VideoXpert Toolbox access shall be coordinated with 92

SFS/ESS.

1.1.14.2 Following activation, the Contractor will email 92SFS/ESS all license(s), entitlement(s), activation key(s) and associated paperwork.

1.1.15 Naming Convention

Each camera location has a designated name that will not change. See building specific appendixes for camera locations/labels.

1.1.16 Appendixes

Included Appendixes will cover building specific locations, details and diagrams. The appendixes will include photos of the buildings and desired camera locations, naming conventions, parts numbers, and quantities required as well as the identified camera fields of views (FOV).

1.1.17 VideoXpert Programming

The Contractor shall provide the Media Access Controls (MAC) along with their ID numbers to the 92 SFS/ESS. Once cameras are communicating across the base network, 92 SFS/ESS will program and assign cameras to the storage manager IAW the building specific appendixes.

1.1.18 As-Builts

As-builts shall be provided in electronic, .pdf format and contain the following:

Camera locations

Naming conventions Wire type [i.e., Ethernet Type (i.e., CAT 6 Shielded, CAT 6 Unshielded)] Camera ID Patch panel port number Router number and port POE Injector information and locations (manufacturer, model & serial numbers, warranty information) Camera manufacturer date, model and serial numbers Router picture depicting the installed equipment and listing all equipment provided to the government

*NO AutoCAD building floor plans/drawings will be provided*

1.1.19 Equipment Testing

1.1.19.1 All cameras shall have latest firmware installed prior to government testing.

1.1.19.2 Before connecting to the base network, each camera feed will be viewed by the contractor. Upon successful camera video views, the contractor will provide each camera’s MAC to 92 SFS/ESS no less than 48 hours prior to testing. 92 SFS/ESS will coordinate with 92 CS/SCOI to update MACs to the applicable network switches.

1.1.19.3 Once the MACs are added to the respective network switches, 92 SFS/ESS will inform the Contractor and schedule the testing date.

1.1.19.4 Upon installation, each camera shall be tested to verify the following:

Recording Live feed Using VideoXpert software, verify each camera can be viewed based on the degree of coverage (i.e., Fixed, 180, 360 degrees) Zoom close, far, up, down Validate picture quality (washout, brightness) No pixelated or distorted camera views No obstructions, distortion, tearing, hum-bars, rolling Camera movement (choppy/fluid) Lens (free of dirt, smudges, cracks, protective film)

1.1.20 Final Acceptance

This SOW shall be used for the Government Acceptance Test (GAT). The Contractor shall provide written notice to the government no later than 48 hours prior to the final acceptance date and time. 92 SFS/ESS will conduct a final walk through and report any discrepancies to the Contractor. Once Final Acceptance is issued, *NO* close-out documents will be signed until ALL required documentation and as-builts are provided IAW this SOW.

1.1.21 Work Site

The contractor shall clean the work sites at the end of each installation day. Removal of debris and disposal off-base is mandatory. Clean cardboard ONLY may be recycled at the base Recycle Center.

1.1.22 Installation Manuals, Guides, and Pamphlets

The Contractor will provide soft or hard copy of all manufacturer installation manuals, guides, and literature to the government.

1.1.23 Quality Control

The contractor shall utilize their own internal quality control processes and procedures in performance of this requirement to guarantee quality services. The Contractor shall develop and implement procedures to identify, prevent, and ensure non-recurrence of unsatisfactory services.

The government will conduct random Quality Assurance Evaluation of all Contractor work.

Should instances of unsatisfactory performance be recurring, the Contractor’s quality control plan and supporting documentation shall be made available to the government upon request.

1.1.24 Warranty

The Contractor shall honor standard warranties by PELCO after the GAT. Acceptance by the government will be pursuant upon a completed test and certification of the installed equipment.

All equipment shall be purchased new, in the most recent model, to mitigate potentially voided warranty from long shelf time prior to installation. Prior to GAT, the Contractor will provide the government each installed component’s warranty manufacturer, date of purchase, model number, serial number, and warranty expiration date.

2. General Information

2.1 Hours of Operation

Normal hours of operation are Monday – Friday, 0730 – 1630, excluding federal holidays and/or when the government facility is closed due to local or national emergencies, administrative closings, or similar government directed facility closing.

January 1 New Year’s Day 3rd Monday in January Martin Luther King, Jr. Day 3rd Monday in February President’s Day Last Monday in May Memorial Day June 19 Juneteenth Day July 4 Independence Day 1st Monday in September Labor Day 2nd Monday in October Columbus Day November 11 Veteran’s Day 4th Thursday in November Thanksgiving Day December 25 Christmas Day

2.2 Certifications

The contractor shall provide the government with current training documents/certificate copies for installation technicians. In the event of a new or recertification for PELCO and VideoXpert

3.15 and later systems, hardware, software, and equipment installation. The contractor will maintain current certifications and adherence to PELCO standards for the duration of the contract period of performance.

2.3 Access to Base Network

Contract personnel requiring access to the Air Force network shall have completed a National Agency Check verified through the Joint Personnel Adjudication system. This is accomplished by completing the Electronic Personnel Security Questionnaire or if applicable, completing the SF 85P, Questionnaire for Public Trust Positions. Personnel shall submit all required forms through the 92 SFS for submission to the Office of Personnel Management IAW AFMAN 16- 1405 Air Force Personnel Security Program dated 1 Aug 2018.

2.4 Base Access

The Contractor shall adhere to all local base policies and regulations to access Fairchild Air Force Base including coordination for base access with 92 SFS at least 7 days prior to the requested installation start date.

2.5 Physical Security

The Contractor shall be responsible for safeguarding all government equipment, information, and property provided for Contractor use. At the close of each work period, government facilities, equipment, and materials secured. Additionally, all resources (i.e., maps, publications, instructions, photos) provided by the government to assist during the period of performance shall be surrendered upon termination of employment or the completion and final acceptance of the requirements. The Contractor shall *NOT* take any photographs of camera equipment, components, cables, power supplies, flight line, aircraft, etc. without the expressed consent of the government.

2.6 Utilities

The government will provide electricity and water services if required by the Contractor.

2.7 Escorts

The government point-of-contact shall appoint active military members to escort the Contractor and personnel as required.

3 APPENDICES

Appendix A Camera Software Appendix B Building 1250 Appendix C Building 2257 Appendix D Building 2259 Appendix E Building 2266

APPENDIX A

CAMERA SOFTWARE

PELCO VideoXpert Ops Center 3.15

PELCO VideoXpert Toolbox 3.15

Air Force Network Operating System Windows 10

APPENDIX B

BUILDING 1250

Part Number / Items list:

ITEM QTY CAMERA EQUIPMENT PART #

1 58 VideoXpert Licenses E1-1C

2 1 VideoXpert Storage Server, T-Series, RAID 6, 144TB, PELCO VXS2-T144-12

3 5 Exterior 4K Pan, Tilt, & Zoom Infrared Cameras P2820-ESR 4 53 Interior and Stairwell Fixed Infrared Cameras IMP531-1IRS

TOTAL: 117

Camera Naming Convention:

Exterior Cameras (E)

ID LABEL TYPE NOTES

FOV

DISTANCE

E1 Bldg. 1250 South East PTZ Infrared/4K 1500 Ft E2 Bldg. 1250 South West PTZ Infrared/4K 1500 Ft E3 Bldg. 1250 West PTZ Infrared/4K 1500 Ft E4 Bldg. 1250 North West PTZ Infrared/4K 1500 Ft E5 Bldg. 1250 North East PTZ Infrared/4K 1500 Ft

Interior Cameras (I) First Floor

ID LABEL TYPE NOTES

FOV

DISTANCE

I1 Bldg. 1250 1st Floor Lobby Fixed Infrared/Audio 10 x 50 Ft I2 Bldg. 1250 1st Floor A & B Wing North Hallway Fixed Infrared/Audio 5 x 50 Ft I3 Bldg. 1250 1st Floor Briefing Rm 104 Fixed Infrared/Audio 20 x 30 Ft I4 Bldg. 1250 1st Floor Laundry Rm B108 Fixed Infrared/Audio 15 x 25 Ft I5 Bldg. 1250 1st Floor Computer Rm B109 Fixed Infrared/Audio 10 X 10 Ft I6 Bldg. 1250 1st Floor Game Rm B110 Fixed Infrared/Audio 10 x 20 Ft I7 Bldg. 1250 1st Floor East Storage Rm B113 Fixed Infrared/Audio 15 x 65 Ft I8 Bldg. 1250 1st Floor West Storage Rm B113 Fixed Infrared/Audio 15 x 65 Ft I9 Bldg. 1250 1st Floor North West Storage Rm B113 Fixed Infrared/Audio 15 x 65 Ft

I10 Bldg. 1250 1st Floor A & B Wing South Hallway Fixed Infrared/Audio 5 x 50 Ft I11 Bldg. 1250 1st Floor A Wing East Hallway [1A] Fixed Infrared/Audio 5 x 40 Ft I12 Bldg. 1250 1st Floor A Wing East Hallway [1B] Fixed Infrared/Audio 5 x 40 Ft I13 Bldg. 1250 1st Floor A Wing East Hallway [2A] Fixed Infrared/Audio 5 x 40 Ft I14 Bldg. 1250 1st Floor A Wing East Hallway [2B] Fixed Infrared/Audio 5 x 40 Ft I15 Bldg. 1250 1st Floor South Emergency Stairwell Fixed Infrared/Audio 10 X 10 Ft I16 Bldg. 1250 1st Floor B & C Wing South Hallway Fixed Infrared/Audio 5 x 50 Ft I17 Bldg. 1250 1st Floor B & C Wing North Hallway Fixed Infrared/Audio 5 x 50 Ft I18 Bldg. 1250 1st Floor C Wing East Hallway Fixed Infrared/Audio 5 x 50 Ft I19 Bldg. 1250 1st Floor C Wing West Hallway [1A] Fixed Infrared/Audio 5 x 50 Ft

I20 Bldg. 1250 1st Floor C Wing West Hallway [1B] Fixed Infrared/Audio 5 x 50 Ft I21 Bldg. 1250 1st Floor North Emergency Stairwell Fixed Infrared/Audio 10 X 10 Ft

Interior Cameras Second Floor

ID LABEL TYPE NOTES

FOV

DISTANCE

I22 Bldg. 1250 2nd Floor A Wing East Hallway [2B] Fixed Infrared/Audio 5 x 40 Ft I23 Bldg. 1250 2nd Floor A Wing East Hallway [2A] Fixed Infrared/Audio 5 x 40 Ft I24 Bldg. 1250 2nd Floor A Wing East Hallway [1B] Fixed Infrared/Audio 5 x 40 Ft I25 Bldg. 1250 2nd Floor A & B Wing South Hallway Fixed Infrared/Audio 5 x 50 Ft I26 Bldg. 1250 2nd Floor A Wing East Hallway [1A] Fixed Infrared/Audio 5 x 40 Ft I27 Bldg. 1250 2nd Floor A & B Wing North Hallway Fixed Infrared/Audio 5 x 50 Ft I28 Bldg. 1250 2nd Floor B Wing Center Hallway [1A] Fixed Infrared/Audio 5 x 50 Ft I29 Bldg. 1250 2nd Floor Kitchen Hallway Rm B205 Fixed Infrared/Audio 5 x 15 Ft I30 Bldg. 1250 2nd Floor Computer Rm B208 Fixed Infrared/Audio 10 x 25 Ft I31 Bldg. 1250 2nd Floor Game Rm B207 Fixed Infrared/Audio 10 x 25 Ft I32 Bldg. 1250 2nd Floor Laundry Rm B206 Fixed Infrared/Audio 15 x 32 Ft I33 Bldg. 1250 2nd Floor B Wing Center Hallway [1B] Fixed Infrared/Audio 5 x 50 Ft I34 Bldg. 1250 2nd Floor C Wing North Hallway [1A] Fixed Infrared/Audio 5 x 50 Ft I35 Bldg. 1250 2nd Floor C Wing North Hallway [1B] Fixed Infrared/Audio 5 x 50 Ft I36 Bldg. 1250 2nd Floor C Wing East Hallway Fixed Infrared/Audio 5 x 50 Ft I37 Bldg. 1250 2nd Floor C Wing West Hallway [1A] Fixed Infrared/Audio 5 x 50 Ft I38 Bldg. 1250 2nd Floor C Wing West Hallway [1B] Fixed Infrared/Audio 5 x 50 Ft

Interior Cameras Third Floor

ID LABEL TYPE NOTES

FOV

DISTANCE

I39 Bldg. 1250 3rd Floor A Wing East Hallway [2B] Fixed Infrared/Audio 5 x 40 Ft I40 Bldg. 1250 3rd Floor A Wing East Hallway [2A] Fixed Infrared/Audio 5 x 40 Ft I41 Bldg. 1250 3rd Floor A Wing East Hallway [1B] Fixed Infrared/Audio 5 x 40 Ft I42 Bldg. 1250 3rd Floor A & B Wing South Hallway Fixed Infrared/Audio 5 x 50 Ft I43 Bldg. 1250 3rd Floor A Wing East Hallway [1A] Fixed Infrared/Audio 5 x 40 Ft I44 Bldg. 1250 3rd Floor A & B Wing North Hallway Fixed Infrared/Audio 5 x 50 Ft I45 Bldg. 1250 3rd Floor B Wing Center Hallway [1A] Fixed Infrared/Audio 5 x 50 Ft I46 Bldg. 1250 3rd Floor Kitchen Hallway Rm B305 Fixed Infrared/Audio 5 x 15 Ft I47 Bldg. 1250 3rd Floor Computer Rm B308 Fixed Infrared/Audio 10 x 25 Ft I48 Bldg. 1250 3rd Floor Game Rm B307 Fixed Infrared/Audio 10 x 25 Ft I49 Bldg. 1250 3rd Floor Laundry Rm B306 Fixed Infrared/Audio 15 x 32 Ft I50 Bldg. 1250 3rd Floor B Wing Center Hallway [1B] Fixed Infrared/Audio 5 x 50 Ft I51 Bldg. 1250 3rd Floor C Wing North Hallway [1A] Fixed Infrared/Audio 5 x 50 Ft I52 Bldg. 1250 3rd Floor C Wing North Hallway [1B] Fixed Infrared/Audio 5 x 50 Ft I53 Bldg. 1250 3rd Floor C Wing East Hallway Fixed Infrared/Audio 5 x 50 Ft

Building 1250 Exterior Camera information:

Building 1250 Interior Camera Information:

APPENDIX

BUILDING 2257

Part Numbers / Item list:

ITEM QTY CAMERA EQUIPMENT PART #

1 21 VideoXpert Licenses E1-1C 2 4 Exterior 4K Pan, Tilt, & Zoom Infrared Cameras P2820-ESR 3 17 Interior and Stairwell Fixed Infrared Cameras IMP531-1IRS

TOTAL: 42

Camera Naming Conventions:

Exterior Cameras (E)

ID LABEL TYPE NOTES

FOV

DISTANCE

E1 Bldg. 2257 North PTZ Infrared/20X Zoom 1500 Ft E2 Bldg. 2257 West PTZ Infrared/20X Zoom 1500 Ft E3 Bldg. 2257 South West PTZ Infrared/20X Zoom 1500 Ft E4 Bldg. 2257 South PTZ Infrared/20X Zoom 1500 Ft E5 Bldg. 2257 North Stairwell Fixed Infrared 30 Ft E6 Bldg. 2257 South Stairwell Fixed Infrared 30 Ft

Interior Cameras (I)

ID LABEL TYPE NOTES

FOV

DISTANCE

I1 Bldg. 2257 1St Floor South Fixed Infrared 50 Ft I2 Bldg. 2257 1st Floor North Fixed Infrared 50 Ft I3 Bldg. 2257 Lobby Fixed Infrared 30 Ft I4 Bldg. 2257 Rear Entrance Fixed Infrared 30 Ft I5 Bldg. 2257 2nd Floor North Fixed Infrared 50 Ft I6 Bldg. 2257 2nd Floor South East Fixed Infrared 50 Ft I7 Bldg. 2257 3rd Floor South Fixed Infrared 50 Ft I8 Bldg. 2257 3rd Floor North Fixed Infrared 50 Ft I9 Bldg. 2257 4th Floor North Fixed Infrared 50 Ft I10 Bldg. 2257 4th Floor South East Fixed Infrared 50 Ft I11 Bldg. 2257 Day Rm 402 Fixed Infrared 25 Ft I12 Bldg. 2257 5th Floor South Fixed Infrared 50 Ft I13 Bldg. 2257 5th Floor North Fixed Infrared 50 Ft I14 Bldg. 2257 6th Floor North Fixed Infrared 50 Ft I15 Bldg. 2257 6th Floor South East Fixed Infrared 50 Ft

Building 2257 Exterior Camera Information:

Building 2257 Interior Camera Information:

BUILDING 2259

Parts List / Item Numbers:

ITEM QTY CAMERA EQUIPMENT PART #

1 21 VideoXpert Licenses E1-1C 2 4 Exterior 4K Pan, Tilt, & Zoom Infrared Cameras P2820-ESR 3 17 Interior and Stairwell Fixed Infrared Cameras IMP531-1IRS

TOTAL: 42

Camera Naming Conventions:

Exterior Cameras (E)

ID LABEL TYPE NOTES

FOV

DISTANCE

E1 Bldg. 2259 North PTZ Infrared/20X Zoom 1500 Ft E2 Bldg. 2259 West PTZ Infrared/20X Zoom 1500 Ft E3 Bldg. 2259 South West PTZ Infrared/20X Zoom 1500 Ft E4 Bldg. 2259 South PTZ Infrared/20X Zoom 1500 Ft E5 Bldg. 2259 North Stairwell Fixed Infrared 30 Ft E6 Bldg. 2259 South Stairwell Fixed Infrared 30 Ft

Interior Cameras (I)

ID LABEL TYPE NOTES

FOV

DISTANCE

I1 Bldg. 2259 1St Floor South Fixed Infrared 50 Ft I2 Bldg. 2259 1st Floor North Fixed Infrared 50 Ft I3 Bldg. 2259 Lobby Fixed Infrared 30 Ft I4 Bldg. 2259 Rear Entrance Fixed Infrared 30 Ft I5 Bldg. 2259 2nd Floor North Fixed Infrared 50 Ft I6 Bldg. 2259 2nd Floor South East Fixed Infrared 50 Ft I7 Bldg. 2259 3rd Floor South Fixed Infrared 50 Ft I8 Bldg. 2259 3rd Floor North Fixed Infrared 50 Ft I9 Bldg. 2259 4th Floor North Fixed Infrared 50 Ft I10 Bldg. 2259 4th Floor South East Fixed Infrared 50 Ft I11 Bldg. 2259 Day Rm 402 Fixed Infrared 25 Ft I12 Bldg. 2259 5th Floor South Fixed Infrared 50 Ft I13 Bldg. 2259 5th Floor North Fixed Infrared 50 Ft I14 Bldg. 2259 6th Floor North Fixed Infrared 50 Ft I15 Bldg. 2259 6th Floor South East Fixed Infrared 50 Ft

Building 2259 Exterior Camera Information:

BLDG 2259 Interior Camera Information:

BUILDING 2266

Part Numbers / Item List

ITEM QTY CAMERA EQUIPMENT PART #

1 9 VideoXpert Licenses E1-1C 2 3 Exterior 4K Pan, Tilt, & Zoom Infrared Cameras P2820-ESR 3 6 Interior and Stairwell Fixed Infrared Cameras IMP531-1IRS

TOTAL: 18

Camera Naming Conventions

Exterior (E)

ID LABEL TYPE NOTES

FOV

DISTANCE

E1 Bldg. 2266 North PTZ Infrared/20X Zoom 1500 Ft E2 Bldg. 2266 West PTZ Infrared/20X Zoom 1500 Ft E3 Bldg. 2266 South West PTZ Infrared/20X Zoom 1500 Ft E4 Bldg. 2266 North Stairwell 1st

Floor Fixed Infrared 30 Ft

E5 Bldg. 2266 South Stairwell 2nd

Floor Fixed Infrared 30 Ft

E6 Bldg. 2266 North Stairwell 3rd

Floor Fixed Infrared 30 Ft

Interior (I)

ID LABEL TYPE NOTES

FOV

DISTANCE

I1 Bldg. 2266 Lobby Fixed Infrared 50 Ft I2 Bldg. 2266 Rear Entrance Fixed Infrared 50 Ft I3 Bldg. 2266 Day Rm 4th Floor Fixed Infrared 30 Ft

BLDG 2266 Exterior Camera Information:

BLDG 2266 Interior Camera Information: