Attachment 1 Statement of Work.pdf

PDF 317 KB Posted

Attached to
Concrete Water Crossing for USDA ARS in Bushland, TX
Solicitation number
1232SA25Q0538
Issued by

About this file

This Performance Work Statement (PWS) details a procurement request by the USDA Agricultural Research Service for constructing a reinforced concrete water crossing and drop structure at the Conservation and Production Research Laboratory in Bushland, Texas. The project requires building a 20-foot wide by 60-foot long improved ford with six-inch thick steel-reinforced concrete, including a 20-foot by 8-foot water spreading drop structure with a 1-foot vertical drop at a 1:2 slope to reduce water erosion.

The technical specifications call for ½-inch rebar placed on 1-foot centers, concrete with 4,000 psi compressive strength, and a flat bottom with 20-foot transitions sloping upward to meet existing roadway surfaces. The project is located at geographic coordinates 35°10'37"N 102°05'32"W, with the primary purpose of enabling all-weather access to the 1,500-acre federal property and preventing erosion of the existing unimproved ford. The required delivery date is 30 July 2024, and the procurement method involves soliciting bids from local vendors.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UNITED STATES DEPARTMENT of AGRICULTURE

AGRICULTURE RESEARCH SERVICE

CONSERVATION and RESEARCH LABORATORY 2300 Experiment Station Road

Bushland, Texas, 79012

April 8, 2025

Summary of Procurement Request for a Purchase

Requirement Name: Concrete water crossing and drop structure

Suggested Method of Procurement: bids from local vendors

POC: Steve Evett, LD Email: steve.evett@usda.gov Cell: 806-584-1018

Prior Contract: N/A

Required Delivery Date: 1 through 30 July 2025

Performance Work Statement / Statement of Work:

General Information:

Background and Purpose: The USDA, Agricultural Research Service (USDA-ARS) requires an improved ford (low water crossing) at 35°10'37"N 102°05'32"W to enable all-weather access to federal property and goods and to prevent erosion of the existing unimproved ford. The Conservation and Production Research Laboratory (CPRL) conducts field crop research. The purpose of the request is to replace an existing unimproved ford with a reinforced concrete improved ford at an entrance to the property from County Road 34 (see Figure 1). This procurement action is to replace the unimproved ford, which is badly eroding to the point of stopping traffic from entering and exiting the property, with a reinforced concrete ford. Due to the size of the laboratory grounds (1,500 acres), a viable all-weather entrance from County Road 34 is essential to allow entrance and egress, which can become a safety issue if a wildfire occurs. To protect assets at the Conservation and Production Research Laboratory (CPRL), 2300 Experiment Station Road, Bushland, Texas 79012, it is necessary to purchase this improved concrete ford.

1. Definitions:

1. USDA: Unites States Department of Agriculture

2. ARS: Agricultural Research Service

3. CPRL: Conservation and Production Research Laboratory

4. SOW: Statement of Work

5. NRCS: USDA Natural Resources Conservation Service

6. Ford: A type of water crossing consisting of a low spot in a roadway

CONTRACTOR REQUIREMENTS:

2. Technical Requirements/Tasks:

The objective is to purchase the construction of a reinforced concrete improved ford consisting of steel reinforced concrete six inches thick over an area of 20 feet by 60 feet with drop structure on east side (Fig. 1 and Fig. 2).

mailto:steve.evett@usda.gov

CONSERVATION and RESEARCH LABORATORY

Contractor Requirements:

The requirement is excavation of soil, placement of steel reinforcing bars, and placement of concrete according to Figure 1 and product specifications.

Product Specifications:

1. Improved reinforced concrete ford width of 20 feet.

2. Improved ford length in direction of travel of 60 feet.

3. Reinforced concrete to be six inches thick with ½-inch rebar on 1-foot centers throughout and compressive strength of 4,000 psi.

4. Improved ford flat bottom of 20 feet length and level in direction of travel, with 20-foot transitions sloping upward to roadway on either side in direction of travel.

5. Water spreading drop structure with dimensions of 20 feet by 8 feet in plan view (Fig.

1) and sloping drop of 1 foot at 1:2 slope on downstream side of ford bottom to a flat apron to reduce erosive energy of water flows per Figure 2, also made with reinforced concrete per item 3.

6. Placement such that transition to existing roadway and surrounding terrain is smooth.

3. Deliverable / Schedule:

Key Deliverables

Item No. Deliverable Objective Due

1 Improved ford Per above technical requirements / task 30 July 2024

4. Government Furnished:

5. Travel:

N/A

6. Contractor’s Key Personnel:

N/A

7. Security Requirements:

N/A

8. Data Rights:

N/A

9. Section 508 – Electronic and Information Technology Standards:

N/A

10. Performance Requirement Measures:

N/A

CONSERVATION and RESEARCH LABORATORY

11. Market Research Quotes (if any): Three quotes and information included

12. GSA Source: N/A

Figure 1. Approximate position and size of improved reinforced concrete ford to replace existing unimproved dirt ford in entrance road. Black outline is reinforced concrete with middle third being the 20 feet of level bottom and the outside two thirds being sloped upward to meet the existing road surface. The red outline is the approximate size and shape of the reinforced concrete drop structure.

CONSERVATION and RESEARCH LABORATORY

Figure 2. Cross-section view of bottom of improved reinforced concrete ford showing drop structure and flat apron.

5. Travel: