This document is a Statement of Work (SOW) for the demolition and removal of 4 concrete/metal stock tanks and installation of 4 fiberglass stock tanks at the Oklahoma & Central Plains Agricultural Research Center (OCPARC), Southern Plains Experimental Range (SPER) in Woodward, Oklahoma.
The SOW outlines the specific requirements, including providing all materials, labor and expertise to demolish and remove the existing tanks and piping, clean the concrete pads, and install 3 - 24'x2' and 1 - 12'x2' heavy duty, single seam, two ply side and bottom, fiberglass stock tanks. The new tanks must include new overflow piping and removable fence panels/gates. The work is to be performed during standard business hours, Monday through Friday, excluding federal holidays. A mandatory site visit is required prior to submitting an offer.
The related federal contract opportunity is Solicitation Number 12805B24Q0378 for the Demolition and Removal of 4 Concrete/Metal Stock Tanks and Replacement with Fiberglass Tanks. This is a small business set-aside with a NAICS code of 115115, Farm Labor Contractors and Crew Leaders, and a size standard of $19.0 Million. Offers are due by August 5, 2024 at 1:00 p.m. Central and will be awarded as a firm-fixed price purchase order.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 12805B24Q0378 Combined Synopsis Solicitation.pdf | ||
| Attachment 2 Wage Determination.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
PURPOSE AND CONTENT
The Oklahoma & Central Plains Agricultural Research Center (OCPARC), Southern Plains Experimental Range (SPER) 2000 18th Street, Woodward, OK 73801 is in need of the demolition and removal of 4 concrete/metal stock tanks and installation of 4 fiberglass stock tanks.
BACKGROUND
The Facilities and Site
SPER consists of approximately 5,400 acres and is currently engaged in developing and improving native grasses and wheat pasture supplementation research for grazing cattle. The 4 concrete/metal stock tanks and continuous fencing being replaced are over 25 years old.
Specific Requirements and Specifications
1. Provide all materials, labor and expertise to demo and remove 4 existing stock tanks piping and fencing and install new, four (4) single seam, heavy duty fiberglass stock tanks equal or comparable to WW Tanks, with additional accessories, and fencing.
2. Clean existing concrete pads and replace old overflow piping.
3. Install three (3) 24’x2’ and one (1) 12’x2’ heavy duty, single seam, two ply side and bottom, fiberglass stock tanks equal or comparable to WW fiberglass tanks as per manufacture recommendations.
4. Install new overflow piping to match existing size, configuration, and to a sufficient depth to provide protection from hazards imposed by traffic, animals and freezing.
5. Install new removable fence panels/gates to separate watering areas in the same tank without uprights in tank. (see fig. 1)
6. Clean up old materials, trash and debris resulting from the tear-out and install.
7. Inspect and test new stock tanks.
8. Work hours: 7:00am-4:00pm, Monday-Friday except for recognized Federal
Holidays. Work outside of these hours requires the prior consent of the Contracting Officer.
9. Site visit attendance is mandatory to provide an offer on this solicitation. Site Visit details will be included in the solicitation.
Point of Contact:
Joe Goodballet, Facility Maintenance Representative Oklahoma & Central Plains Agricultural Research Center USDA, Agricultural Research Service 2000 18th Street Woodward, OK 73801 Phone: 580-571-6434, Fax: 580-256-1322, Email, joe.goodballet@usda.gov
Current Metal Tank Example:
mailto:joe.goodballet@usda.gov
Current Concrete Tank Example:
Example of Fence to be removed:
Example of Configuration of Replacement:
SPER consists of approximately 5,400 acres and is currently engaged in developing and improving native grasses and wheat pasture supplementation research for grazing cattle. The 4 concrete/metal stock tanks and continuous fencing being replaced are ov...
File details come from the government source that posted it. Updated .