Attachment 1 Specifications.pdf
PDF 190 KB Posted
- Attached to
- Pivot Irrigation Replacement Federal contract opportunity
- Solicitation number
- 12805B24Q0499
About this file
This document is an Attachment 1 Specifications document related to a federal contract opportunity for the replacement of four irrigation pivot systems at the Roman L. Hurska U.S. Meat Animal Research Center in Clay Center, Nebraska.
The specifications provide detailed requirements for the replacement of four irrigation pivots, including general specifications such as minimum structural and control feature requirements, sprinkler package design, and drive system specifications. The pivots are to be installed in specific locations in Clay County, Nebraska, with a required completion date of December 31, 2024. The government point of contact is Danny Trausch.
The related federal contract opportunity is Solicitation Number 12805B24Q0499 for "Pivot Irrigation Replacement", a small business set-aside with a NAICS code of 811310 and a $12.5M size standard. Quotes are due by August 14, 2024, and the government intends to award a firm fixed price purchase order to the responsible offeror whose quote conforms to the specifications and is the most advantageous based on technical acceptance, past performance, and price.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_12805B24Q0499_Amd_0002.pdf | ||
| Sol_12805B24Q0499_Amd_0001.pdf | ||
| Sol_12805B24Q0499.pdf | ||
| Attachment 2 Wage Determination 2015-5357 Rev 22.pdf | ||
| Attachment 3 Site Visit Information.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 1 Specifications
Specifications Document: 36CD, 74AB, 44CD, 53B IRRIGATION PIVOT SYSTEMS SPECIFICATION
BACKGROUND AND PURPOSE:
Scientists at the Roman L. Hurska U.S. Meat Animal Research Center (USMARC) are developing scientific information and new technologies to solve high priority problems for the U.S. beef, swine, and sheep industries. USMARC can produce a large amount of the feed required to feed such a large animal population. Nearly all the fields used to produce forage and other feeds are under pivots to keep the crops properly watered and at peek production. Due to extreme weather conditions resulting in damage to four pivots we are needing full replacement of each of the four.
CONTRACTOR REQUIREMENTS:
36CD pivot replacement:
GENERAL SPECIFICATIONS
Pivot will be installed in south 80 of section NW quarter 7-6-7W, and north 80 of SW quarter in 7-6-7W in Clay County Nebraska. This pivot is currently a 1990’s T/L System with a total wetted radius of approximately 1370 feet.
Equipment manufacturer shall have a continuous production record of center pivot irrigation systems for a minimum of 15 years.
The center pivot system(s) provided by the manufacturer shall be of their latest and proven design.
All structural members of the center pivot systems including the pipe, shall be hot-dipped galvanized on all surfaces. Certain nominal items/brackets may be painted.
System should be of standard height with a minimum 105” ground clearance at the lowest truss. Wheelbase shall be minimum 150”.
The center pivot system shall be equipped with 11.2” x 38” 8 ply+ non-directional tires and appropriately sized wheels.
Existing chemigation valve, flow meter and service pipe may be reused on new installation. If existing equipment is not reusable, include replacement prices with pivot bid.
The center pivot systems shall be a minimum of seven towers, overall length of approximately 1296 feet.
Typical ¼ section center pivot, site visitation is required to ensure that pivot is optimally sized to maintain existing irrigated acres and avoids obstacles located under the pivot.
One copy of all pertinent instruction and/or operation manuals shall be provided with each center pivot installed.
Materials, equipment, and services not specifically mentioned in these specifications, but obviously required for the completion of the installation, shall be provided, or installed by the successful offeror as though fully specified and shown.
SYSTEM CONTROL FEATURES:
Travel direction and application depths with at least 16 programable sectors controlled at pivot point.
GPS Position and remote control ready.
Application depth changes automatically by field position using VRI sector programming.
Endgun, stop in slot, and auto reverse controlled and set from pivot point electronically and remote control ready.
Automatic start up on water pressure for 480-volt systems.
Beacon light located at pivot point indicating operation status.
SPRINKLER PACKAGE:
The system shall be designed and installed to meet the following criteria:
Design flow of 5.6 GPM/ACRE minimum but the well pumps 800 GPM currently.
The pivot is currently serviced by a natural gas engine powered by a T/L hydraulic pump.
Top inlet pressure 30 to 35 PSI, End pressure 20 to 25 PSI with Nelson Rotators.
Sprinkler package – Standard outlet spacing for the system. Preference for an above pipe sprinkler package. Sprinkler packages for perennial pasture should be of type and/or design that will not apply water on tower wheel tracks.
A Nelson SR-100 (or equal) end gun with pressure booster pump, sized to match water distribution of main spans.
One copy of sprinkler package design printout shall be provided for each pivot.
The systems will be used on primarily level upland Hastings and Crete silty clay loams.
Specifications for Hydrostatic drive center pivot systems:
Hydrostatic drive systems shall meet all the structural, control features and general specifications previously described and the following:
Irrigation system should be equipped with swivel pivot point.
A separate or attached concrete pad shall be installed at pivot points, that are not currently equipped, for mounting of the hydraulic pump.
All necessary hydraulic and electrical hookups shall be made by the successful bidder.
Specifications for electric drive center pivot systems:
Electric drive systems shall meet all the structural, control features and general specifications previously described and the following:
All electrical controls and installations should meet or exceed NEMA specifications. Systems shall be properly grounded in accordance with the National Electric Code.
Surge and over current protection: Lightning arrestor.
All necessary electrical hookups shall be made by the successful bidder.
A new 15KW Lima generator will need to be included/installed with this bid.
74AB pivot replacement:
GENERAL SPECIFICATIONS
Pivot will be installed in half section of 33-7-8W in Clay County Nebraska. This pivot is currently a 2012-2015 T/L System with a total wetted radius of approximately 1370 feet and is situated in the middle of the section.
Equipment manufacturer shall have a continuous production record of center pivot irrigation systems for a minimum of 15 years.
The center pivot system(s) provided by the manufacturer shall be of their latest and proven design.
All structural members of the center pivot systems including the pipe, shall be hot-dipped galvanized on all surfaces. Certain nominal items/brackets may be painted.
System should be of standard height with a minimum 105” ground clearance at the lowest truss. Wheelbase shall be minimum 150”.
The center pivot system shall be equipped with 11.2” x 38” 8 ply+ non-directional tires and appropriately sized wheels.
Existing chemigation valve, flow meter and service pipe may be reused on new installation. If existing equipment is not reusable, include replacement prices with pivot bid.
The center pivot systems shall be a minimum of seven towers, overall length of approximately 1296 feet.
Typical ¼ section center pivot, site visitation is required to ensure that pivot is optimally sized to maintain existing irrigated acres and avoids obstacles located under the pivot. This pivot is in an irrigated pasture with water tanks and the pivot must be measured to miss the water tanks and permanent fences established.
One copy of all pertinent instruction and/or operation manuals shall be provided with each center pivot installed.
Materials, equipment, and services not specifically mentioned in these specifications, but obviously required for the completion of the installation, shall be provided, or installed by the successful offeror as though fully
Travel direction and application depths with at least 16 programable sectors controlled at pivot point.
Design flow of 5.6 GPM/ACRE minimum but the well pumps 800 GPM currently.
The pivot is serviced by 480 volts at the pivot point.
Top inlet pressure 30 to 35 PSI, End pressure 20 to 25 PSI with Nelson Rotators.
package. Sprinkler packages for perennial pasture should be of type and/or design that will not apply water on tower wheel tracks.
A Nelson SR-100 (or equal) end gun with pressure booster pump, sized to match water distribution of main spans.
A separate or attached concrete pad shall be installed at pivot points, that are not currently equipped, for
Electric drive systems shall meet all the structural, control features and general specifications previously described and the following:
All electrical controls and installations should meet or exceed NEMA specifications. Systems shall be
44CD pivot replacement:
GENERAL SPECIFICATIONS
Pivot will be installed in west half section of 36-7-8W in Clay County Nebraska. This pivot is currently a 1990’s Valley System with a total wetted radius of approximately 1370 feet.
Equipment manufacturer shall have a continuous production record of center pivot irrigation systems for a minimum of 15 years.
The center pivot system(s) provided by the manufacturer shall be of their latest and proven design.
All structural members of the center pivot systems including the pipe, shall be hot-dipped galvanized on all surfaces. Certain nominal items/brackets may be painted.
System should be of standard height with a minimum 105” ground clearance at the lowest truss. Wheelbase shall be minimum 150”.
The center pivot system shall be equipped with 11.2” x 38” 8 ply+ non-directional tires and appropriately sized wheels.
Existing chemigation valve, flow meter and service pipe may be reused on new installation. If existing equipment is not reusable, include replacement prices with pivot bid.
The center pivot systems shall be a minimum of seven towers, overall length of approximately 1284 feet.
Typical ¼ section center pivot, site visitation is required to ensure that pivot is optimally sized to maintain existing irrigated acres and avoids obstacles located under the pivot.
One copy of all pertinent instruction and/or operation manuals shall be provided with each center pivot installed.
Materials, equipment, and services not specifically mentioned in these specifications, but obviously required for the completion of the installation, shall be provided, or installed by the successful offeror as though fully
Travel direction and application depths with at least 16 programable sectors controlled at pivot point.
Design flow of 5.6 GPM/ACRE minimum but the well pumps 800 GPM currently.
The pivot is serviced by 480 volts at the pivot point from generator ran from a natural gas engine.
Top inlet pressure 35-40 PSI, End pressure 25 to 30 PSI with Nelson Rotators.
package. Sprinkler packages for perennial pasture should be of type and/or design that will not apply water on tower wheel tracks.
A Nelson SR-100 (or equal) end gun with pressure booster pump, sized to match water distribution of main spans.
A separate or attached concrete pad shall be installed at pivot points, that are not currently equipped, for
Electric drive systems shall meet all the structural, control features and general specifications previously described and the following:
All electrical controls and installations should meet or exceed NEMA specifications. Systems shall be
All necessary electrical hookups shall be made by the successful bidder.
A new 15KW Lima generator will need to be included/installed with this bid.
53B pivot replacement:
GENERAL SPECIFICATIONS
Pivot will be installed in half section of 26-7-8W in Clay County Nebraska. This pivot is currently a 2015-2020 Reinke System with a total wetted radius of approximately 1370 feet and is situated in the middle of the section.
Equipment manufacturer shall have a continuous production record of center pivot irrigation systems for a minimum of 15 years.
The center pivot system(s) provided by the manufacturer shall be of their latest and proven design.
All structural members of the center pivot systems including the pipe, shall be hot-dipped galvanized on all surfaces. Certain nominal items/brackets may be painted.
System should be of standard height with a minimum 105” ground clearance at the lowest truss. Wheelbase shall be minimum 150”.
The center pivot system shall be equipped with 11.2” x 38” 8 ply+ non-directional tires and appropriately sized wheels.
Existing chemigation valve, flow meter and service pipe may be reused on new installation. If existing equipment is not reusable, include replacement prices with pivot bid.
The center pivot systems shall be a minimum of seven towers, overall length of approximately 1296 feet.
Typical ¼ section center pivot, site visitation is required to ensure that pivot is optimally sized to maintain existing irrigated acres and avoids obstacles located under the pivot. This pivot is in an irrigated pasture with water tanks and the pivot must be measured to miss the water tanks and permanent fences established.
One copy of all pertinent instruction and/or operation manuals shall be provided with each center pivot installed.
Materials, equipment, and services not specifically mentioned in these specifications, but obviously required for the completion of the installation, shall be provided, or installed by the successful offeror as though fully
Travel direction and application depths with at least 16 programable sectors controlled at pivot point.
Design flow of 5.6 GPM/ACRE minimum but the well pumps 800 GPM currently.
The pivot is serviced by 480 volts at the pivot point from generator ran from a natural gas engine.
Top inlet pressure 35 to 40 PSI, End pressure 25 to 30 PSI with Nelson Rotators.
package. Sprinkler packages for perennial pasture should be of type and/or design that will not apply water on tower wheel tracks.
A Nelson SR-100 (or equal) end gun with pressure booster pump, sized to match water distribution of main spans.
A separate or attached concrete pad shall be installed at pivot points, that are not currently equipped, for
Electric drive systems shall meet all the structural, control features and general specifications previously described and the following:
All electrical controls and installations should meet or exceed NEMA specifications. Systems shall be
A new 15KW Lima generator will need to be included/installed with this bid.
Deliverable/Schedule/Address:
Normal business hours are anticipated for installation, but 1 weeks’ notice of prior approval to install the each pivot is required. Installation is anticipated to be in summer/fall of 2024 but must be installed before December 31, 2024.
USMARC
844 Road 313 Clay Center, NE 68933
36CD 74AB 44CD 53B
South 80 of section NW quarter 7-6-7W, and north 80 of SW quarter in 7-6-7W in Clay County Nebraska
East half section of 33-7-8W in Clay County Nebraska
West half section of 36-7- 8W in Clay County
Nebraska
East half section of 26-7-8W in Clay County
Nebraska
Key Deliverables
Item No. Deliverable Objective
1 Fully equipped pivot installed in 36CD
One (1) pivot delivered and installed by December 31, 2024.
2 Fully equipped pivot installed in 74AB
One (1) pivot delivered and installed by December 31, 2024.
3 Fully equipped pivot installed in 44CD
One (1) pivot delivered and installed by December 31, 2024.
4 Fully equipped pivot installed in 53B
One (1) pivot delivered and installed by December 31, 2024.
Government Point of Contact:
Danny Trausch, 402-762-4120, danny.trausch@usda.gov mailto:danny.trausch@usda.gov
| BACKGROUND AND PURPOSE: |
| GENERAL SPECIFICATIONS |
| Design flow of 5.6 GPM/ACRE minimum but the well pumps 800 GPM currently. |
| The pivot is currently serviced by a natural gas engine powered by a T/L hydraulic pump. |
| Top inlet pressure 30 to 35 PSI, End pressure 20 to 25 PSI with Nelson Rotators. |
| Sprinkler package – Standard outlet spacing for the system. Preference for an above pipe sprinkler package. Sprinkler packages for perennial pasture should be of type and/or design that will not apply water on tower wheel tracks. |
| Specifications for Hydrostatic drive center pivot systems: |
| Irrigation system should be equipped with swivel pivot point. |
| A separate or attached concrete pad shall be installed at pivot points, that are not currently equipped, for mounting of the hydraulic pump. |
| All necessary hydraulic and electrical hookups shall be made by the successful bidder. |
| Specifications for electric drive center pivot systems: |
| All necessary electrical hookups shall be made by the successful bidder. |
| A new 15KW Lima generator will need to be included/installed with this bid. |
| GENERAL SPECIFICATIONS |
| Design flow of 5.6 GPM/ACRE minimum but the well pumps 800 GPM currently. |
| The pivot is serviced by 480 volts at the pivot point. |
| Top inlet pressure 30 to 35 PSI, End pressure 20 to 25 PSI with Nelson Rotators. |
| Sprinkler package – Standard outlet spacing for the system. Preference for an above pipe sprinkler package. Sprinkler packages for perennial pasture should be of type and/or design that will not apply water on tower wheel tracks. |
| Specifications for Hydrostatic drive center pivot systems: |
| Irrigation system should be equipped with swivel pivot point. |
| A separate or attached concrete pad shall be installed at pivot points, that are not currently equipped, for mounting of the hydraulic pump. |
| All necessary hydraulic and electrical hookups shall be made by the successful bidder. |
| Specifications for electric drive center pivot systems: |
| All necessary electrical hookups shall be made by the successful bidder. |
| GENERAL SPECIFICATIONS |
| Design flow of 5.6 GPM/ACRE minimum but the well pumps 800 GPM currently. |
| The pivot is serviced by 480 volts at the pivot point from generator ran from a natural gas engine. |
| Top inlet pressure 35-40 PSI, End pressure 25 to 30 PSI with Nelson Rotators. |
| Sprinkler package – Standard outlet spacing for the system. Preference for an above pipe sprinkler package. Sprinkler packages for perennial pasture should be of type and/or design that will not apply water on tower wheel tracks. |
| Specifications for Hydrostatic drive center pivot systems: |
| Irrigation system should be equipped with swivel pivot point. |
| A separate or attached concrete pad shall be installed at pivot points, that are not currently equipped, for mounting of the hydraulic pump. |
| All necessary hydraulic and electrical hookups shall be made by the successful bidder. |
| Specifications for electric drive center pivot systems: |
| All necessary electrical hookups shall be made by the successful bidder. |
| A new 15KW Lima generator will need to be included/installed with this bid. |
| GENERAL SPECIFICATIONS |
| Design flow of 5.6 GPM/ACRE minimum but the well pumps 800 GPM currently. |
| The pivot is serviced by 480 volts at the pivot point from generator ran from a natural gas engine. |
| Top inlet pressure 35 to 40 PSI, End pressure 25 to 30 PSI with Nelson Rotators. |
| Sprinkler package – Standard outlet spacing for the system. Preference for an above pipe sprinkler package. Sprinkler packages for perennial pasture should be of type and/or design that will not apply water on tower wheel tracks. |
| Specifications for Hydrostatic drive center pivot systems: |
| Irrigation system should be equipped with swivel pivot point. |
| A separate or attached concrete pad shall be installed at pivot points, that are not currently equipped, for mounting of the hydraulic pump. |
| All necessary hydraulic and electrical hookups shall be made by the successful bidder. |
| Specifications for electric drive center pivot systems: |
| A new 15KW Lima generator will need to be included/installed with this bid. |
| All necessary electrical hookups shall be made by the successful bidder. |
| Normal business hours are anticipated for installation, but 1 weeks’ notice of prior approval to install the each pivot is required. Installation is anticipated to be in summer/fall of 2024 but must be installed before December 31, 2024. |
| USMARC |
| 844 Road 313 |
| Clay Center, NE 68933 |
| Government Point of Contact: |
| Danny Trausch, 402-762-4120, danny.trausch@usda.gov |