Attachment_1_-_Specifications.pdf

PDF 154 KB Posted

Attached to
LAKE240032 CARDIAC MONITORS
Solicitation number
140P8124Q0008
Issued by

About this file

This document contains the specifications for cardiac monitor/defibrillator equipment that the National Park Service's Lake Mead National Recreation Area (NRA) is seeking to procure. The scope of the contract includes supplying and delivering the cardiac monitors, which must be brand name or equal to the Philips Tempus ALS monitor/defibrillator system. The required items include the monitor, accessories such as ECG, SpCO, and video laryngoscope components, and associated supplies. Delivery is required within 90 days of order receipt to the Lake Mead NRA location. The quoted items must have a maintenance-free battery with at least 10.75 hour capacity and an integrated video laryngoscope. If proposing an alternate product, the contractor must provide detailed specifications comparing it to the required item.

This specification document is related to the federal contract opportunity LAKE240032 CARDIAC MONITORS, Solicitation Number 140P8124Q0008, issued by the Department of the Interior National Park Service Pacific West Region for two cardiac monitors with accessories.

View the file

Other files

File Type Posted
Sol_140P8124Q0008.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specifications Cardiac Monitor/Defibrillator

Lake Mead National Recreation Area (NRA)

1.1 DESCRIPTION

1.1.1 Lake Mead NRA is in need of replacement cardiac monitor/defibrillators. Significant improvements have been made in cardiac monitor technology making models more portable, more ruggedized, and having improved battery life which allows emergency medical providers to bring this technology into more remote and austere environments which are common in the Recreation Area. These newer monitors also allow for video laryngoscope use which significantly improves success rate of and decreases the time of breathing tube placement in critical patients. These traits allow for emergency medical clinicians to provide better care to patients by bringing improved technology to patients located into more remote environments.

1.1.2 The Scope of this contract consists of:

A. Supplying the Cardiac Monitors B. Deliver or ship the equipment to Lake Mead National Recreation Area (address to be provided)

1.1.3 The contractor shall provide all materials to be purchased described in this specification. All materials shall be new and Contractor-furnished from outside the park.

1.2 Delivery Requirements

1.2.1 Deliver or ship the equipment to the following address:

Lake Mead National Recreation Area 101 Katzenbach Dr Boulder City, NV 89005

1.2.2 On or before 90 days after receipt of order

1.2.3 Delivery costs should be accounted for in the unit prices of the quoted items. Delivery costs should not be quoted as a separate item.

1.3 Required Items

1.3.1 Required items are to be brand name or equal to Philips Tempus ALS monitor/defibrillator system and items below:

Item # Item Description Qty Unit 867422 B73

Tempus Pro, Printer Tempus Pro, US Package 7

2 EA

C01 12 Lead ECG License 2 EA C02 ST & QT Real Time License 2 EA C03 Glasgow ECG algorithm 2 EA M04 SpCO Factory License 2 EA

E04 Inseego 4G Dongle Kit 2 EA 00-3020 Tempus LS MAN DEFIBRILLATOR 2 EA 01-3020 Tempus LS Electrodes-Adult 40 EA 01-3021 Tempus LS Electrodes-Pediatric 8 EA 01-2086 Masimo rainbow DCI Adult-Clip 3 ft 2 EA 01-1003 Reusable NIBP Cuff – Large adult 2 EA 01-1004 Reusable NIBP Cuff - Child 2 EA 989803204551 Capnography Supplies 2 EA 01-2187 Tempus Printer Paper Grid 110mm 2 Box 01-2010 Video Laryngoscope Blade – Size 3 2 Box 01-2011 Video Laryngoscope Blade – Size 4 2 Box 01-2063 Video Laryngoscope D Blade 2 Box 01-2044 USB C-MAC S Imager Video Laryngoscope 2 EA 989803204321 Capnography Supplies 2 EA

PHTPRC520-

BLK

Tempus Pro Independent Case, Black 2 EA

PHTLSDC7201-

BLK

Tempus LS Defibrillator Case, Black 2 EA

1.3.2 The quoted items must have at a minimum the following salient characteristics:

• Two pieces – One for monitoring, one for electrical therapy

• Maintenance free battery with 10.75 hour capacity

• Integrated video laryngoscope

1.3.3 For each "Substitution" or "Comparable Product" the Contractor submits as being "equal" to the product that has been specified, the Contractor shall submit supporting documentation that includes:

A. Detailed comparison of the characteristics of the proposed item with that specified.

B. Name, address, and telephone number of vendor.

C. Product data, including drawings, descriptions, fabrication, and samples as appropriate.

File details come from the government source that posted it. Updated .