- BGNDRF - Repair AHU-01 Evaporator Coil
- Solicitation number
- 140R4025Q0022
About this file
This is a Statement of Work (SOW) for repairing a 10-ton Trane Air Handling Unit (AHU-01) at the Brackish Groundwater National Desalination Research Facility (BGNDRF) in Alamogordo, NM. The Bureau of Reclamation requires repairs to address refrigerant leaks identified in the evaporator coil, including removing and replacing the evaporator coil, thermal expansion valves, and filter dryers, with reuse of existing refrigerant supplemented by new R-22 if needed.
The work includes inspecting and verifying scope, ordering Trane Original Equipment Manufacturer parts, performing lock-out/tag-out procedures, recovering refrigerant, replacing components, evacuating the system, and recharging with recovered/supplemental refrigerant. The period of performance is 60 days after notice to proceed. The contractor must be licensed for HVAC work and certified to handle R-22 refrigerant. The NAICS code is 238220. Key submittals required include a schedule, equipment specifications, safety program, and refrigerant documentation. The facility operates Monday through Friday, 8:00 AM to 4:30 PM MST, and site visits are available upon request. Pricing is structured with separate CLINs for parts, travel, labor, equipment, and optional new R-22 refrigerant.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140R4025Q0022_Amd_0001.pdf | ||
| Coil_and_other_AHU_pics_0001.pdf | ||
| Attachment_3-_WD_NM_2015-5455_dated_12-23-24.pdf | ||
| Attachment_2_-_Price_Schedule.docx | DOCX document | |
| Sol_140R4025Q0022.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work
1.0 - Abbreviations, Definitions, and Acronyms The Bureau of Reclamation commonly uses the following definitions listed below:
AAO Albuquerque Area Office (USBR) ASTM American Society for Testing and Materials (International) BGNDRF Brackish Groundwater National Desalination Research Facility CO Contracting Officer COR Contracting Officer’s Representative CS Contract Specialist DIAR Department of Interior Acquisition Regulation EB Elephant Butte EBHD Elephant Butte Historic District FAR Federal Acquisition Regulation MST Mountain Standard Time NMED New Mexico Environment Department OGR Onsite Government Representative OSHA Occupational Safety and Health Administration RSHS Reclamation Safety and Health Standards UL Underwriters Laboratories USBR Untied States Bureau of Reclamation
2.0 - Introduction The Bureau of Reclamation, Upper Colorado Region, Brackish Groundwater National Desalination Research Facility, (Reclamation) has a need to repair their 10-ton Trane Air Handling Unit (AHU). Leaks have been identified in the evaporative coil and 22 lbs of refrigerant were added November 21, 2024. The expected repairs required to get the unit functional include removing and replacing the evaporator coil, thermal expansion valves, and the filter dryers. The remaining refrigerant must be captured and reused; if needed supplemental R- 22 refrigerant will be required. The contractor must be licensed to perform work on HVAC units, able to recover, add, and purchase R22 refrigerant, and capable of performing the work within a reasonable timeframe.
2.1 – Location and Hours of Operations The Reclamation facility is located at 500 La Velle Road, Alamogordo, NM 88310.
Reclamation’s standard business hours are Monday through Friday from 8:00 AM to 4:30 PM MST except federal holidays.
2.2 – Site Visit Reclamation can host a site visit if requested by prospective bidder.
The current period of performance for this Statement of Work (SOW) is 60 days after notice to proceed, however repairs are requested as soon as possible to lower the amount of additional refrigerant needed. Adjustments to the schedule will be considered if weather will impact quality and safety during the project activities/tasks. An option for purchasing additional refrigerant is included, as it is possible that new R-22 refrigerant will be needed by the time work starts.
2.3 - Background
The Brackish Groundwater National Desalination Research Facility (BGNDRF) is a federal facility that operates under the United States Department of Interior, Bureau of Reclamation
(Reclamation). Established by an Act of Congress, the facility mission is to promote sustainable advanced water treatment research and technology development for inland brackish groundwater sources and, specifically, to conduct research for the development of cost-effective, robust desalination and alternative energy technologies that produce sustainable new supplies of water and power for municipal, industrial, agricultural, and environmental purposes
2.4 – North American Industry Classification System (NAICS) The NAICS for this work is 238220 - Heating, Ventilation, and Air Conditioning (HVAC) contractors.
2.5 - Purpose The purpose is to protect and maintain the federally owned asset. The facility is equipped with a Trane Split System, with a 10-ton Trane condenser installed at ground level outside the building and a 10-ton Trane air handling unit installed inside the building at the mezzanine level. The part number for the AHU is TWE120B00EL and the associated condenser is TTA120B400EA; both have a Manufacturer Date of 10/2006.
The condenser and evaporator were both inspected in November 2024 by an Alamogordo-area HVAC company. Using a dye pack in the refrigerant and an inspection two weeks after new refrigerant was added, leaks were found in the evaporator coil. The service technician suggested replacing the evaporator coil unit, thermal expansion valves, and refrigerant filter dryers.
3.0 – Security and Safety This section describes the security and safety requirements for this Reclamation facility. The following sub-sections provide additional details for various considerations on this effort.
3.1 - Safety Contractor and its subcontractors shall comply and incorporate into their safety and health programs/plans the following safety requirements:
Occupational Safety and Health Administration (OSHA) Part 1926 Construction.
Reclamation Safety and Health Standards (RSHS) which can be found at the following website: https://www.usbr.gov/ssle/safety/RSHS/rshs.html.
The contractor and its subcontractors (if applicable) shall promptly report all facts regarding accidents, near miss(es), emergencies, and/or mishaps involving Government property damage or injury to Government personnel and to cooperate in any resulting safety investigation.
The contractor shall notify the Contracting Officer’s Representative and Contracting Officer by one of the following methods: in person, by telephone, and/or by email within four hours of all incidents. Reclamation’s personnel will notify Reclamation’s Safety and Health office. The contractor shall immediately secure the incident area and any damaged property. If requested by Reclamation Safety and Health office, the Contractor shall submit all pertinent maintenance and training records for equipment or personnel involved in the safety incident(s). If the Government investigates the safety incident, the contractor and the subcontractors shall cooperate fully and assist the Government personnel with the investigation.
4.0 – Provided to Offeror
4.1 – Point of Contact The following key Government personnel are
Contracting Officer: XXX 555 Broadway Blvd., Suite 100 Albuquerque, New Mexico 87102-2352
(505) xxx xxx@usbr.gov
Project Manager/ Malynda Cappelle Contracting Officer’s Representative 500 Lavelle Road Alamogordo, New Mexico 88310-9228
(575) 443-6553 mcappelle@usbr.gov
4.2 – Government provided Utilities The Government will make available electricity for repair activities. The facility restroom will be made available for use by the Contractor.
If project work requires disconnection of any utilities such as electrical, water, HVAC equipment, etc., provide a minimum of 48-hour notice to the Government.
SUMMARY OF WORK
PART 1 GENERAL
1.01 LOCATION
A. Work is located at the Brackish Groundwater National Desalinization Research Facility (BGNDRF), 500 La Velle Road, Alamogordo, NM 88310.
1.02 PRINCIPAL COMPONENTS OF WORK
A. HVAC Component Replacement
1. Inspect AHU-01 Evaporator Coil, Order Parts Verify scope of work is adequate and repairs are feasible.
Identify and order evaporator coil and other parts required for repair
2. Lock Out - Tag Out Affected employees should be notified that the equipment will be shut down and locked out.
Equipment should be shut down using normal shutdown procedures.
All energy sources should be isolated.
Lock and/or tag devices should be attached to switches and energy controls.
Verify equipment cannot be powered on during maintenance.
3. Refrigerant Recovery Refrigerant from each circuit shall be recovered into a new properly labeled recovery cylinder.
Recovered system refrigerant shall be recovered using a new inline filter drier at the inlet of the recovery machine.
The actual weight of the recovered refrigerant shall be recorded.
4. Evaporator Coil Existing evaporator coil unit shall be removed and replaced with Original Equipment
Manufacturer replacement parts from Trane. Original Equipment Manufacturer replacement parts from Trane.
5. Thermal Expansion Valves Existing Thermal Expansion Valves shall be removed and replaced with new Original
Equipment Manufacturer replacement parts from Trane.
6. Filter Drier
Existing filter driers should be removed and replaced with new Original Equipment Manufacturer replacement parts from Trane.
7. Evacuate System The system should be evacuated and held at the manufacturer recommended vacuum micron level for the manufacturer recommended amount of time.
8. System Charge
The system circuits shall be recharged using the recovered refrigerant. If the weight of recovered refrigerant differs from the manufacturer’s recommended weight, additional refrigerant that is like in kind can be added at the direction of the Contracting Officer.
The Trane manual suggests that 18.8 lbs of refrigerant is needed for a 10-ton compressor, however, different temperatures and field installation may require more. 22 lb was added in November 2021.
1.03 SPECIFICATIONS REQUIREMENTS
A. Requirements in Division 1, General Requirements, apply to Divisions 2 through 52.
B. Imperative statements in these specifications are Contractor requirements, unless otherwise stated.
C. Where specifications are written in streamlined form, words “shall be” are included by inference where a colon (:) is used within sentence or phrase.
1.04 DEFINITIONS
A. When specifications use a word or term defined in Federal Acquisition Regulations (FAR), definition of the word or term shall be in accordance with FAR sections in effect at the time solicitation was issued.
1.05 ACRONYMS
A. The following acronyms apply to specifications Divisions 1 through 52:
1. CO: Contracting Officer.
2. COR: Contracting Officer’s Representative.
3. GR: Onsite Government Representative.
PART 2 PRODUCTS
Not Used
PART 3 EXECUTION
3.01 SPECIFIC REQUIREMENTS/TASKS
A. Contractor shall perform its work in a reasonable manner and in accordance with industry standards. Contractor shall furnish and supply the tools, equipment, labor, and materials necessary for the proper performance of its work, except to the extent specifically excluded herein.
3.02 CONTRACTOR FURNISHED PROPERTY
A. The Contractor shall furnish all facilities, materials, equipment and services necessary to fulfill the requirements of this contract, except for the Government Furnished Utilities specified in SOW 4.2.
Not Used
SECTION 01 33 00
SUBMITTALS
PART 1 GENERAL
1.01 REFERENCE STANDARDS
A. American Society of Mechanical Engineers (ASME)
1. ASME Y14.1-12 Decimal Inch Drawing Sheet Size and Format
B. National Institute of Building Sciences (NIBS)
1. NIBS NCS-14 United States National CAD Standards, Version 6
1.02 DEFINITIONS
A. Days: Calendar days.
B. Required Submittal Number (RSN): Identifies items to be submitted together as a complete submittal.
C. Submittal Types, as listed in Table 01 33 00A - List of Submittals:
1. A - Action:
a. Government will respond as to adequacy of submittal.
b. Action submittals are considered to be “shop drawings” within terms of clause at FAR 52.236-21, Specifications and Drawings for Construction.
2. I - Informational:
a. Government will acknowledge receipt of Informational submittals.
b. Government may reject an Informational submittal when submittal does not satisfy contract requirements. Contractor shall correct mistakes or deficiencies in rejected Informational submittals and resubmit.
c. Informational submittals are considered to be “shop drawings” within terms of clause at FAR 52.236-21, Specifications and Drawings for Construction, except that approval by Government is not required.
1.03 SUBMITTAL REQUIREMENTS
A. In case of conflict between requirements of this section and requirements included elsewhere in these specifications, requirements included elsewhere take precedence.
B. General:
1. Prepare in English.
2. Label with contract number and title, and RSN.
3. Measurement Units: US Customary Units
4. Provide a unique transmittal number for each submittal.
C. Drawings:
1. Minimum Identification in Title Block:
a. Contract number and title.
b. Contractor’s or supplier’s title and drawing number.
c. Date.
2. Reserve 3- by 3-inch space next to title block for review stamps.
3. Size: D size (22 inches by 34 inches) as defined by ASME Y14.1.
4. Draw to scale using computer drafting or drafting equipment, unless otherwise specified.
a. Computer drafted drawings:
1) In accordance with NIBS NCS.
2) Electronic file format: Compatible with AUTOCAD, Version 2018 or later.
3) Compile using “eTransmit” utility in AUTOCAD.
b. Drawing prepared with drafting equipment, when allowed: Lettering shall be neat.
5. Drawings Designated as “Government Format” in Specifications:
a. Computer drafted.
b. Government will provide electronic AutoCAD format template.
c. Title block and sheet format:
1) As shown on standard drawing 40-D-7102.
2) Government will supply template.
3) Government will supply specific title block information to be used.
6. Final Drawings:
a. Computer drafted.
b. Government will supply electronic AutoCAD format template.
c. Show as-built changes, including revision dates, made during installation.
Indicate changes by clouding.
7. Electronic Files: On CD or DVD discs.
D. Product Data:
1. Mark manufacturer's data for commercial products or equipment, such as catalog cut sheets.
a. Identify manufacturer's name, type, model, size, and characteristics.
b. Illustrate that product or equipment meets requirements of specifications.
c. Mark items to be furnished in a manner that will photocopy (no highlighter).
d. Strike through items that do not apply.
E. Certifications:
1. Certifications by a registered professional: Signed and sealed by registered professional.
2. Manufacturer’s certifications: Signed by authorized representative of manufacturer.
F. Photographs:
1. Prints: Professional quality 8-inch by 10-inch color for each listed view.
a. Identify with adhesive labels on back.
1) Include contract number, name of equipment and view title.
2) Do not type directly on back of photograph.
2. Include negatives, or digital files on CD or DVD in .jpeg or similar format.
G. Samples and Color Selection Submittals:
1. Label with complete manufacturer's product and color identification.
2. Include type and quantity of materials specified in the referenced section in each “set” of samples.
3. Samples: Representative of product to be installed. Xerographic sheets for color selection are not acceptable.
4. Color Chips: Sample paint chips. Ink color reproductions are not acceptable.
5. Label each sample, sample kit, set of color chips, or color chart with contract number and title.
6. The Government will select architectural color and pattern after product approval.
1.04 SUBMITTALS PROCEDURES
A. Submit only checked submittals. Submittals without evidence of Contractor's approval will be returned for resubmission.
B. Submit complete sets of required materials for each RSN as specified in “Submittals Required” column in Table 01 33 00A - List of Submittals. A complete set includes all listed items for RSNs with multiple parts.
C. Submit number of sets specified in “No. of sets to be sent to:” columns in Table 01 33 00A - List of Submittals.
D. Include the following information in transmittal letters:
1. Contract number and title.
2. RSN for each attached submittal.
3. Responsible code.
4. Number of sets for each RSN.
5. Identify submittal as initial or resubmittal.
E. Resubmittal of submittals not approved:
1. Mark changes such that they are readily identifiable and show revision date.
2. Describe reasons for significant changes in transmittal letter.
3. Resubmit returned submittals within 7 days after receiving comments, unless otherwise directed.
4. Requirements for initial submittals apply to resubmittals.
F. More than 1 RSN may be submitted under a transmittal letter, provided responsible code is same.
1.05 REVIEW OF SUBMITTALS
A. Time Required:
1. Submittal review will require 7 days for review of each submittal or resubmittal, unless otherwise specified.
2. Time required for review of each submittal or resubmittal begins when complete sets of materials required for a particular RSN are received and extends through return mailing postmark date.
B. Time in Excess of Specified:
1. CO may extend contract completion date to allow additional time for completing work affected by excess review time.
a. Time extension will be to extent that excess review time caused delay to contract completion date.
b. Time extension will not exceed time used in excess of specified number of days for review of submittals or resubmittals.
c. Concurrent days of excess review time resulting from review of 2 or more separate submittals or resubmittals will be counted only once in extending contract completion date.
2. No time extension will be allowed if Contractor fails to make complete action submittals in sequence and within time periods specified.
3. Adjustment for delay will be made only to extent that
a. Approval was required under contract, and
b. Requests for approval were properly and timely submitted and were approved.
4. Adjustment will be subject to terms of paragraphs (b) and (c) of the clause at FAR 52.242-14, Suspension of Work; however, no such delay shall be deemed to be a “suspension order” as the term is used in that clause.
C. Return of Submittals:
1. Action Submittals: One set of submittals required for action will be returned either approved, approved with comments, or not approved.
a. Revise and resubmit submittals not approved.
b. Do not change designs without approval of CO after drawings, documentation, and technical data have been approved.
2. Informational Submittals: Government will acknowledge Informational submittals.
a. Informational submittals will not be returned when they satisfy contract requirements.
b. Informational submittals that do not satisfy contract requirements may be returned for resubmittal or additional information may be requested.
1.06 TRANSMITTAL
A. Addresses for codes listed in Table 01 33 00A - List of Submittals:
1. Contracting Officer, Bureau of Reclamation, 555 Broadway Boulevard NE, Albuquerque NM 87102
2. Facility Manager, Bureau of Reclamation, 500 La Velle Rd, Alamogordo NM 88310
B. Send original transmittal letter with appropriate number of sets to office listed in “Responsible Code” column in Table 01 33 00A - List of Submittals.
1. Responsible codes starting with “86-6” are located in Technical Service Center.
Send these submittals to TSC address shown above.
C. Send copy of transmittal letter with appropriate number of sets to offices that are not responsible code, but show “No. of sets to be sent to” in Table 01 33 00A - List of Submittals.
D. When “No. of sets to be sent to” is 0, send a copy of transmittal letter to that office.
E. Submittals required by specifications, but not listed in Table 01 33 00A - List of Submittals:
1. Submit in accordance with this section.
2. Submit to COR, unless otherwise specified.
PART 2 PRODUCTS
Not Used
PART 3 EXECUTION
Not Used
Table 01 33 00A. - List of Submittals
* Submittal Types: A - Action, I - Information ** CO indicates Contracting Officer, COR indicates Contracting Officer Representative, PM indicates Project Manager.
RSN
Clause or
Section Title
Submittals required Due date or delivery time Type
Respon-sible code
No. of sets to be sent to: **
CO COR PM
I-1 Schedule Schedule
Within 14 days before work commences.
I COR 1 1 1
I-2 Trane equipment provided
Spec sheets for evaporator, thermal expansion valves, filter driers
Within 14 days before work commences.
I COR 1 1 1
I-3 Safety and Health (WBR 1452.223-81)
Safety Program Submitted and accepted before commencing onsite work. See section 3 of RSHS
I COR 0 1
I-4 Refrigerant Information
Document R22 removed (lb), NEW R22 added (lb), document pressures at end.
Submitted with (or before) final invoice
I CO/ COR 0 1
I-4 Work Documentation
Manuals, pictures, other information necessary for future troubleshooting
Submitted with (or before) final invoice
I CO/ COR 0 1
END OF SECTION
Price Schedule Line Item No.
Supplies or Services Quantity Unit Unit Price
Amount
CLIN
00010
Parts -Trane OEM
1 Evaporator Unit 1 EA $ $
2 Thermal Expansion Valve 2 EA $ $ 3 Filter Dryer 2 EA $ $ 4 Insulation – outdoor refrigerant lines 15 ft $ $
5 Other (specify) $ $ 6 Other (specify) $ $
CLIN
00020
Travel
1 Round Trip
Miles $ $ 2 Per Diem Days $ $
CLIN
00030
Labor
1 Travel Time HR $ $ 2 Service Time HR $ $
CLIN
00040
Equipment
1 Recovery Cylinder and Filter Dryer
2 EA $ $
Optional Work
New R22 Refrigerant
CLIN00050 R22 Refrigerant addition 22 lb $
Clin 00010-00040 Subtotal $
Taxes and/or Other Fees % $
TOTAL CONTRACT PRICE $
Note: There are four CLINs for this requirement; however, there are multiple sublines needing price breakout. Two lines are provided in CLIN 10, however, they can be left blank if not needed. Indicate whether travel is required and if freight charges are included in pricing for Trane parts.
PROVIDE A DETAILED LISTING FOR EACH TO INCLUDE LABOR CATEGORIES,
LABOR RATES, MATERIAL AND EQUIPMENT LISTING AND ASSOCIATED
RATES
Offers will be considered for award on the following Price Schedule, but no offer will be considered for award on only a part of the Schedule.
Offers are subject to the terms and conditions of this request for proposal.
Picture of AHU-01 showing associated ductwork. The yellow arrow indicates the location of the air handler. The evaporator coil is accessed from the other side. The black arrow indicates the refrigerant lines.
Picture of AHU-01 showing associated ductwork. The yellow arrow indicates the location of the air handler and the access panels for the evaporator coil.
AHU-01 Trane Manufacturer Info
Trane Condenser unit (for awareness – this unit is working)
Split System Cooling Units
Split System Cooling Units
7 1/2 through 20 Ton - 60 Hz
Air Handlers
5 through 20 Ton - 60 Hz
SS-PRC004-ENMarch 2001
Cooling Coils
10 Ton
©American Standard Inc. 2001 SS-PRC004-EN
Introduction
Split System Cooling Units . . .
Designed With Your Needs In Mind.
The Trane reputation for quality and reliability in air conditioning continues with the Odyssey™ family of light commercial split systems. Trane paid attention to your needs to make sure you get a system that will meet your job requirements every time...and at a competitive price.
Couple Trane’s reputation for quality and reliability in split system air conditioners with efficiency, flexibility and installation ease...and you have systems that will give you “ Simply the Best Value”.
Manufacturing Control
Trane’s exclusive control over the design and manufacturing of all major components is unique in the industry.
This approach assures us total control over both the quality and reliability of these components. And allows us to custom match components to deliver the best in split system performance.
Designing the Details
Careful attention was given to designing the details — from control wiring to the access panels. Odyssey units feature time-saving colored and numbered wiring and removable panels which allow complete access to all major components and controls. All outdoor units feature external high and low pressure switches for easy diagnosing and servicing of the unit. And service valves with gauge ports are provided.
Standardized Cabinets
In addition all cabinets have been standardized; so when you are servicing an outdoor unit or an air handler all components are in the same location from unit to unit.
Filters
The 5, 7½ and 10 ton air handlers are supplied with 1" throwaway filters as standard. The filter racks were designed to easily convert for installation of 2" filters. The 15 and 20 ton air handlers are supplied with 2" filters as standard.
UL Listed and ARI Certified
Trane meets or exceeds all nationally recognized agency safety and design standards. Each condensing unit is UL designed, approved, and labeled in accordance to UL Standards: UL 1995 for central cooling air conditioners, refrigeration and air conditioning condensing and compressor units. Each air handler is designed, approved and labeled in accordance to UL 465 and UL 1995 standard for heat pumps. Each unit is certified in accordance with ARI Standard 210/360 or 365.
Contents
SS-PRC004-EN
Introduction
Features and Benefits
Application Considerations
Selection Procedure
Model Number Description
General Data
Performance Data
Cooling Performance Fan Performance
Controls
Electric Power
Dimension and Weights
Mechanical Specifications
SS-PRC004-EN4
Features and Benefits
Condensing Unit Options
The Odyssey split system product line includes condensing units in single, unloading and dual compressor options.
The 7½ and 10-ton single compressor models feature single refrigeration circuitry lowering job installation costs by requiring only one set of refrigerant lines. These units are ideal for the low cost, new construction jobs as well as renovation and replacement buildings.
Equally important, Odyssey offers a single refrigerant circuit/capacity unloading option in 10 and 15 ton condensing units. These unloading units feature dual manifolded scroll compressors. They offer an excellent opportunity for both new construction and replacement jobs with two stages of capacity modulation and a single refrigeration circuit.
In addition, Odyssey includes a 10, 12½, 15 and 20-ton dual compressor unit to give true stand-by protection; if one compressor fails, the second will automatically start-up. Also, the first compressor can be serviced without shutting down the unit since refrigerant circuits are independent.
Dual compressors are not just for protection, they also save energy costs. Most buildings are designed for the peak load requirements yet the building usually operates at less than peak load. During light load conditions only one compressor functions to maintain the space comfort thus reducing the need for energy. For instance, the EER of the 10-ton unit at ARI conditions is 9.5 and at part load conditions it is 10.3.
Trane split systems have been specified in thousands of applications and you’ll find Odyssey will win you even more jobs with it’s smaller, more manageable cabinet. This lighter, compact design will save time and money for rigging and installation. And the compactness will permit Trane’s unit to replace almost any unit — effortlessly.
Low Ambient Cooling Operation
Each condensing unit can operate to 35°F (1.6°C) as standard. An accessory Head Pressure Control gives you the capability to operate to 0°F (-18°C). All condensing units offer these accessories:
• Head Pressure Control
• Coil Guard Kits
• Isolators both Rubber-in-Shear and
Spring Type
• Anti-Short-Cycle Kit
• Time Delay Relay
• Black Epoxy Coated Coil
Air Handlers Offer More Flexibility
Flexibility is a key to meeting changing market requirements. Odyssey split systems offer not only various compressor options but also convertible air handlers. The air handlers can be installed either vertically in a mechanical room or horizontally above a ceiling. And it doesn’t require any removal of panels to make either airflow application work.
These air handlers have a double sloped condensate drain pan that allows for either airflow configuration. And the drain pan can easily be removed for cleaning. All the air handlers feature factory-installed belt drive and ball bearing evaporator fans with adjustable sheaves for maximum airflow performance. In fact, the standard motor on the 10-ton air handler will deliver 4000 cfm (6796 m3/h) at 1.4” ESP (350 Pa). Additionally, oversized motors are available for higher static applications.
5SS-PRC004-EN
Odyssey — A Complete Split System
Odyssey delivers the flexibility to select a complete system that meets your particular job requirements. Air handlers are designed, tested, and rated with outdoor units to let you select the proper match between capacity and load. Heat pumps can also be matched with Trane built-up air handlers. Also, these matched systems can be quickly engineered for specific applications using Trane’s computerized selection and load programs.
Odyssey air handler versatility is further increased by a complete line of accessories designed to match and install smoothly:
• Discharge Plenum and Grille
• Return Grille
• Subbase
• Electric Heaters
• High Static Evaporator Motor
• Isolators both Rubber-in-Shear and
Spring Type
• A Full Line of Thermostats
• Outdoor Thermostat
Odyssey Lowers Installation Costs
Your installation costs are reduced with Odyssey. Both outdoor units and air handlers are factory packaged and assembled so jobsite installation is quick and easy. You get a complete unit with all the components, controls and the internal wiring factory ready for a smooth jobsite start-up.
Unlike some competitive models the following components are factory-installed in Trane air handlers:
l Single Point Power Entry l Blower wheel and housing l Evaporator motor with sheaves and pulleys l Low Voltage Terminal Board l Transformer (Most Models) l Contactor l Fan relay l DX Coil with complete refrigeration circuitry l Expansion Valve and Check Valves
There’s no need to install components and put together the air handler on the job. This provides you with less labor cost and fewer chances for installation errors which cause callbacks. All this means saving you money both in replacement and new construction applications.
Features and Benefits
SS-PRC004-EN6
Application Considerations
Low Ambient Cooling
As manufactured, these units can operate to 35° F (1.6°F) in the cooling mode of operation. An accessory head pressure control will allow operation to 0° F (-18°C) outdoor ambient. When using these units with control systems such as bypass changeover Variable Air Volume, make sure you consider the requirement for a head pressure control to allow low ambient cooling.
Application of this product should be within the catalogued airflow and performance considerations. The System Selection Program will simulate product performance for a set of given conditions. It is recommended that the program should be run at the lowest outdoor ambient and supply air flow rates requiring cooling or heating operation for a particular unit. For more information on the System Selection Program contact your local Trane Representative.
Clearance Requirements
The recommended clearances identified with unit dimensions should be maintained to assure adequate serviceability, maximum capacity and peak operating efficiency. Actual clearances which appear inadequate should be reviewed with the local Trane Representative.
180° Blower Rotation
The 5, 7½, and 10 ton air handler blower section can be rotated 180° to change the discharge pattern. This modification must be done in the field and requires an addition of kit. See unit installer's guide.
Typical Split System Application
Typical Horizontal Air Handler Application
ATTACHING
Typical Vertical Air Handler Application
DISCHARGE PLENUM
AND GRILL ASSEMBLY
HEATING COIL AND
ENCLOSURE ASSEMBLY
AIR HANDLER
RETURN AIR GRILLE
SUB-BASE
ISOLATORS
(SPRING OR RUBBER)
VERTICAL DRAIN
HORIZONTAL
DRAIN
7SS-PRC004-EN
Selection Procedure
TTA Cooling Capacity Step 1 — Calculate the building’s total and sensible cooling loads at design conditions. Use the Trane calculation form or any other standard accepted method.
Step 2 — Size the equipment using Table PD-1. Match the cooling loads at design conditions.
Example: The following are the building cooling requirements:
A Electrical Characteristics: 460/60/3 B Summer Design Conditions:
Entering Evaporator Coil:
80° F (26.6° C) DB/67° F (19.4° C) WB
Outdoor Ambient: 95° F (35° C)
C Total Cooling Load: 88 MBh (25KW) D Sensible Cooling Load: 64 MBh (19 KW) E Airflow: 3000 cfm (5097 m3/hr)
External Static Pressure:
0.73 in. w.g. (183 Pa)
Table PD-1 shows that a TTA090A4 matched with a TWE090A has a gross cooling capacity of 89.9 MBh (26 kW) and 64.3 MBh (19 kW) sensible capacity at 95° F (35° C) DB ambient and 3000 cfm (5097 m3/hr) with 80° F (26.6° C) DB/ 67° F (19.4° C) WB air entering the evaporator.
To find the net cooling capacities, fan motor heat must be subtracted.
Determine the total unit static pressure:
External Static 0.77 in (191 Pa) Standard Filter 1 in. 0.10 in (25 Pa) Supplementary Electric Heat 0.23 in (57 Pa) Total Static Pressure 1.10 in (272 Pa) Note: The Evaporator Fan Performance Table has included the effect of a 1 in.
filter already. Therefore, the actual Total Static Pressure is 1.10 in. – 0.10 in. = 1.00
in. (275 Pa - 25 Pa = 250 Pa).
With 3000 cfm (5097 m3/hr) and 1.00 inches (250 Pa), Table PD-25 shows a 1.17 Bhp (.87 kW).
Note: The formula below the table can be used to calculate Fan Motor Heat,
3.5 X Bhp = MBh
(1.375 x kW = kW)
3.5 X 1.17 = 4.10 MBh
(1.375 x kW = 1.2 kW)
Net Total Cooling Capacity = 89.9 MBh - 4.10 MBh = 85.80 MBh (= 26 kW - 1.2 kW = 25 kW)
Net Sensible Cooling Capacity = 64.3 MBh - 4.10 MBh = 60.20 MBh (=19 kW - 1.2 kW = 18 kW)
Heating Capacity Step 1 — Calculate the building heating load using the Trane calculation form or other standard accepted method.
Step 2 — Size the system heating capacity to match the calculated building heating load. The following are building heating requirements:
A Total Heating Load at 97.0 MBh (28 kW) B 3000 cfm (5097 m3/hr) C Electric Supplementary Heaters
From Table PD-42, the 34.88 kW heater has a capacity of 119,045 Btuh. From Table ED-5, the 34.88 kW at 460v indicates the heater model number is BAYHTRL435A. This heater will adequately cover the building’s heating requirement.
Air Delivery Selection External static pressure drop through the air distribution system has been calculated to be 0.77 inches of water gauge (193 Pa). From Table PD-41 static pressure drop through the electric heater is 0.23 inches of water (0.77 in. + 0.23 in.
= 1.00 in. (193 Pa + 58 Pa = 250 Pa). Enter Table PD-25 for TWE090A4 at 3000 cfm (5097 m3/hr) and 1.00” (250 Pa) static pressure. The standard motor at 821 RPM will give the desired airflow.
SS-PRC004-EN8
Model Number Description
Digit 9, 10 - Factory - Installed Options
00 = Packed Stock 0S = Black Epoxy Coated Coil
Digit 8 - Electrical Characteristics
3 = 208-230/60/3 4 = 460/60/3 K = 380/60/3
Split System Condensing Unit Model Nomenclature
Digits 1, 2, 3 - Product Type
TTA = Split System Cooling
Digits 4, 5, 6 - Nominal Gross Cooling
Capacity (MBh)
090 = 7½ Tons 120 = 10 Tons 150 = 12½ Tons 180 = 15 Tons 240 = 20 Tons
Digit 7- Major Development Sequence
A = Single Compressor B = Dual Compressor C = Dual Manifolded
Compressors Digit 12- Service Digit
A = First
Digit 11- Minor Design Sequence
B = Second
T T A 0 9 0 A 3 0 0 B A
1 2 3 4 5 6 7 8 9 10 11 12
Air Handler Model Nomenclature
Digit 9, 10 - Factory - Installed Options
00 = Packed Stock
Digit 8 - Electrical Characteristics
1 = 208-230/60/1 3 = 208-230/60/3 4 = 460/60/3 K = 380/60/3
Digits 1, 2, 3 - Product Type
TWE = Split System Heat Pump/ Cooling Air Handler
Digits 4, 5, 6 - Nominal Gross Cooling
Capacity (MBh)
060 = 5 Tons 090 = 7½ Tons 120 = 10 Tons 180 = 15 Tons 240 = 20 Tons
Digit 7- Refrigerant Circuit
A = Single B = Dual
Digit 12- Service Digit
A = First
Digit 11- Minor Design Sequence
C = Third
T W E 0 9 0 A 1 0 0 C A
1 2 3 4 5 6 7 8 9 10 11 12
9SS-PRC004-EN
General Data (Condensing Units)
Table GD-1 General Data — 7½, 10 Ton Condensing Units
7½ Ton 10 Ton 10 Ton 10 Ton Single Compressor Single Compressor Dual Compressor Manifolded Compressors
TTA090A3, A4, AK TTA120A3, A4, AK TTA120B3, B4, BK TTA120C3, C4
Cooling Performance1
Gross Cooling Capacity Matched Air Handler (kW) 90,000 (26.35) 123,000 (36.01) 122,000 (35.72) 122,000 (35.72)
Condensing Unit Only2 (kW) 89,000 (26.06) 122,000 (35.72) 119,000 (34.84) 122,000 (35.72) ARI Net Cooling Capacity3 (kW) 87,000 (25.47) 119,000 (34.84) 118,000 (34.55) 118,000 (34.55)
EER4
Matched Air Handler (COP) 9.5 (2.79) 9.2 (2.70) 8.9 (2.49) 9.4 (2.75) Condensing Unit Only (COP) 10.3 (3.02) 10.0 (2.92) 9.9 (2.90) 10.6 (3.10) System Integrated Part Load Value5 — — 9.8 12.5 Condensing Unit Only IPLV5 — — 11.87 13.8
System kW/Condensing Unit kW 9.14/8.63 12.9/12.23 13.88/12.00 12.55/11.53 Compressor
No./Type 1/Trane 3-D® Scroll 1/Trane 3-D® Scroll 2/Trane Climatuff® 2/Manifolded Scrolls No. Motors/HP (kW) 1/7.50 (5.59) 1/10.00 (7.46) 2/5.00 (3.73) 2/5.00 (3.73) Motor RPM 3450 3450 3450 3450
Sound Rating (BELS)6 8.8 8.8 9.0 8.8 System Data7
No. Refrigerant Circuits 1 1 2 1 Suction Line - in. (mm) OD 13/8 (34.93) 13/8 (34.93) 11/8 (28.58) 13/8 (34.93) Liquid Line - in. (mm) OD ½ (12.70) ½ (12.70) 3/8 (9.53) ½ (12.70)
Outdoor Coil - Type Plate Fin Plate Fin Plate Fin Plate Fin Tube Size - in. (mm) OD .375 (9.53) .375 (9.53) .375 (9.53) .375 (9.53) Face Area - sq ft (m2) 15.33 (1.42) 18.4 (1.71) 18.4 (1.71) 18.4 (1.71) Rows/FPI 2/20 2/20 2/20 2/20
Outdoor Fan - Type Propeller Propeller Propeller Propeller No. Used/Diameter - in. (mm) 1/26 (660.40) 1/28 (711.20) 1/28 (711.20) 1/28 (711.20) Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 Cfm (m3/h) 5,670 (9633.38) 7,790 (13235.29) 7,790 (13235.29) 7,790 (13235.29) No. Motors/HP (kW) 1/.50 (0.37) 1/1.00 (0.75) 1/1.00 (0.75) 1/1.00 (0.75) Motor RPM 1100 1100 1100 1100
Refrigerant Charge (Field Supplied) (Lbs of R-22)8 (kg) 13.0 (5.90) 16.0 (7.26) 18.8 (8.53) 15.5 (7.03)
NOTES:
1. Cooling Performance is rated at 95°F (35°C)ambient, 80°F (27°C) entering dry bulb, 67°F (19°C) entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360-93.
2. Condensing Unit Only Gross Cooling Capacity rated at 45°F (7°C) saturated suction temperature and at 95°F (35°C) ambient.
3. ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft. (7.62 m) of 1 3/8" (34.9 mm), 1/2" (12.7 mm) OD interconnecting tubing.
4. EER is rated at ARI conditions and in accordance with DOE test procedures.
5. Integrated Part Load Value is based On ARI Standard 210/240, 340/360 or 365. Units are rated at 80°F (27°C) ambient, 80°F (27°C) entering dry bulb, and 67°F (19°C) entering wet bulb at ARI rated cfm.
6. Sound Rating shown is tested in accordance with ARI Standard 270.
7. System Data based on maximum linear length 80 ft. (24 m) Maximum lift: suction 60 ft. (18 m), liquid 60 ft. (18 m) For greater lengths, refer to refrigerant piping applications manual.
8. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft. (7.6 m) of interconnecting refrigerant lines. All units are shipped with a small nitrogen holding charge only.
SS-PRC004-EN10
Data (Condensing Units)
Table GD-2 General Data — 12½, 15 and 20 Ton Condensing Units
12½ Ton 15 Ton 15 Ton 20 Ton Dual Compressor Dual Compressor Manifolded Compressors Dual Compressor
TTA150B3, B4, BK TTA180B3, B4, BK TTA180C3, C4, CK TTA240B3, B4, BK
Cooling Performance1
Gross Cooling Capacity Matched Air Handler (kW) 152,000 (44.51) 182,000 (53.29) 182,000 (53.29) 241,000 (70.56) Condensing Unit Only2 (kW) 146,000 (42.75) 181,000 (53.00) 177,000 (51.83) 236,000 (69.10)
ARI Net Cooling Capacity3 (kW) 148,000 (43.33) 177,000 (51.83) 176,000 (51.53) 234,000 (68.52)
EER4
Matched Air Handler (COP) 9.3 (2.74) 9.5 (2.77) 9.5 (2.78) 9.0 (2.64) Condensing Unit Only2 (COP) 10.3 (3.01) 10.3 (3.05) 10.6 (3.11) 9.8 (2.89) System Integrated Part Load Value5 11.1 11.2 12.0 10.9 Condensing Unit Only IPLV5 11.9 12.9 14.0 12.3
System kW/Condensing Unit kW 15.81/14.2 18.68/17.39 18.52/16.65 25.98/23.90 Compressor
No./Type 2/Trane Climatuff® 2/Trane 3-D® Scrolls 2 /Manifolded 3-D® Scrolls 2/Trane 3-D® Scrolls No. Motors/HP (kW) 2/6.25 (4.66) 2/7.50 (5.59) 2/7.50 (5.59) 2/10.00 (7.46) Motor RPM 3450 3450 3450 3450
Sound Rating (BELS)6 8.8 8.8 9.0 8.8 System Data7
No. Refrigerant Circuits 2 2 1 2 Suction Line - in. (mm) OD 11/8 (28.58) 13/8 (34.93) 15/8 (41.28) 13/8 (34.93) Liquid Line - in. (mm) OD 3/8 (9.53) ½ (12.70) 5/8 (15.88) ½ (12.70)
Outdoor Coil - Type Plate Fin Plate Fin Plate Fin Plate Fin Tube Size - in. (mm) OD .375 (9.53) .375 (9.53) .375 (9.53) .375 (9.53) Face Area - sq ft (m2) 24.0 (2.23) 30.7 (2.85) 30.7 (2.85) 43.8 (4.07) Rows/FPI 2/18 2/20 2/20 2/15
Outdoor Fan - Type Propeller Propeller Propeller Propeller No. Used/Diameter - in. (mm) 1/28 (711.20) 2/26 (660.40) 2/26 (660.40) 2/28 (711.20) Drive Type/No. Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM (m3/h) 8,120 (13795.96) 10,900 (18519.23) 11,340 (19266.77) 16,120 (27388.04) No. Motors/HP (kW) 1/1.00 (0.75) 2/.50 (0.37) 2/.50 (0.37) 2/1.00 (0.75) Motor RPM 1100 1100 1100 1100
Refrigerant Charge (Field Supplied) (Lbs of R-22)8 (kg) 25.2 (11.43) 27.2 (12.34) 27.0 (12.25) 36.0 (16.33)
NOTES:
1. Cooling Performance is rated at 95°F (35°C)ambient, 80°F (27°C) entering dry bulb, 67°F (19°C) entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net and includes the effect of fan motor heat. Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360-93.
2. Condensing Unit Only Gross Cooling Capacity rated at 45°F (7°C) saturated suction temperature and at 95°F (35°C) ambient.
3. ARI Net Cooling Capacity is calculated with matched blower coil and 25 ft. (7.62 m) of 1 3/8" (34.9 mm), 1/2" (12.7 mm) OD interconnecting tubing.
4. EER is rated at ARI conditions and in accordance with DOE test procedures.
5. Integrated Part Load Value is based On ARI Standard 210/240, 340/360 or 365. Units are rated at 80°F (27°C) ambient, 80°F (27°C) entering dry bulb, and 67°F (19°C) entering wet bulb at ARI rated cfm.
6. Sound Rating shown is tested in accordance with ARI Standard 270.
7. System Data based on maximum linear length 80 ft. (24 m) Maximum lift: suction 60 ft. (18 m), liquid 60 ft. (18 m) For greater lengths, refer to refrigerant piping applications manual.
8. Refrigerant (operating) charge is for condensing unit (all circuits) with matching blower coils and 25 ft. (7.6 m) of interconnecting refrigerant lines. All units are shipped with a small nitrogen holding charge only.
11SS-PRC004-EN
Data (Air Handlers)
Table GD-3 General Data — Air Handlers
5 Ton 5 Ton 7½ Ton 7½ Ton 10 Ton Single Circuit Dual Circuit Single Circuit Dual Circuit Single Circuit
TWE060A1, A3 TWE060B1,
A4, AK B3, B4 TWE090A1,A31, AK TWE090B1,B31 TWE120A1 TWE120A31, AK
System Data No. Refrigerant Circuits 1 2 1 2 1 1 Suction Line OD - in. (mm) 1 1/8 (28.58) 3/4 (19.05) 1 3/8 (34.93) 1 1/8 (28.58) 1 3/8 (34.93) 1 3/8 (34.93) Liquid Line OD - in. (mm) 3/8 (9.53) 5/16 (7.94) 1/2 (12.70) 3/8 (9.53) 1/2 (12.70) 1/2 (12.70)
Indoor Coil - Type Plate Fin Plate Fin Plate Fin Plate Fin Plate Fin Plate Fin Tube Size - in. .375 .375 .375 .375 .375 .375 Face Area - sq. ft. (m2) 5.0 (0.46) 5.0 (0.46) 8.1 (0.75) 8.1 (0.75) 11.2 (1.04) 11.2 (1.04) Rows/FPI 3/12 3/12 3/12 3/12 3/12 3/12 Refrigerant Control Expansion Valve Expansion Valve Expansion Valve Expansion Valve Expansion Valve Expansion Valve Drain Connection Size -in. 1 PVC 1 PVC 1 PVC 1 PVC 1 PVC 1 PVC
Indoor Fan - Type Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal Centrifugal No. Used/Diameter x Width - in. (mm) 1 / 12 x 12 1 / 12 x 12 1 / 15 x 15 1 / 15 x 15 1 / 15 X 15 1 / 15 x 15
(1 / 30.48 x 30.48) (1 / 30.48 x 30.48) (1 / 38.1 x 38.1) (1 / 38.1 x 38.1) (1 / 38.1 x 38.1) (1 / 38.1 x 38.1) Drive Type/ No. Speeds Belt/Adjustable Belt/Adjustable Belt/Adjustable Belt/Adjustable Belt/Adjustable Belt/Adjustable CFM (m3/h) 2000 (3398) 2000 (3398) 3000 (5097) 3000 (5097) 4000 (6796) 4000 (6796) No. Motors 1 1 1 1 1 1 Motor HP (kW) - Standard/Oversized .75/1.00 (.56/.75) .75/1.00 (.56/.75) 1.50/2.00 (1.12/1.49) 1.50/2.00 (1.12/1.49) 2.00/3.00 (1.49/—) 2.00/3.003 (1.49/2.243) Motor Rpm 17252 1725 1725 1725 1725 1725 Motor Frame Size 56 56 56H 56H 56HZ 56HZ
Filters - Type/Furnished Throwaway/Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes Throwaway/Yes
(No.) Size Recommended - in. [mm] (1) 16 x 20 x 1 (1) 16 x 20 x 1 (3) 16 x 25 x 1 (3) 16 x 25 x 1 (4) 16 x 25 x 1 (4) 16 x 25 x 1
(1) 20 x 20 x 1 (1) 20 x 20 x 1
[(1) 40.6 x 50.8 x 2.54][(1) 40.6 x 50.8 x 2.54][(3) 40.6 x 63.5 x 2.54] [(3) 40.6 x 63.5 x 2.54][(4) 40.6 x 63.5 x 2.54][(4) 40.6 x 63.5 x 2.54] [(1) 50.8 X 50.8 X 2.54][(1) 50.8 X 50.8 X 2.54]
ARI tested and certified with various heat pumps in accordance with ARI Standard 210/240 or 340/360-93 certification program. Refer to Performance Data section in this catalog.
NOTES:
1. Ships wired for 208-230/3/60. Field convertible to 460/3/60.
2. TWE060A1 has Motor RPM of 3450 for oversized motor.
3. TWE120A1 does not have an oversized motor option.
Table GD-3 — Continued
10 Ton 15 Ton 20 Ton Dual Circuit Dual Circuit Dual Circuit
TWE120B31
TWE120B1 TWE120BK TXE120B500B TWE180B3, B4, BK TWE240B3, B4, BK
System Data
No. Refrigerant Circuits 2 2 2 2 2 Suction Line OD - in. (mm) 1 1/8 (28.58) 1 1/8 (28.58) 1 1/8 (28.58) 1 3/8 (34.93) 1 3/8 (34.93) Liquid Line OD - in. (mm) 3/8 (9.53) 3/8 (9.53) 3/8 (9.53) 1/2 (12.70) 1/2 (12.70)
Indoor Coil - Type Plate Fin Plate Fin Plate Fin Plate Fin Plate Fin Tube Size (in.) .375 .375 .375 .375 .375 Face Area - sq. ft. (m2) 11.2 (1.04) 11.2 (1.04) 11.2 (1.04) 16.3 (1.51) 21.6 (2.01) Rows/FPI 3/12 3/12 3/12 3/12 3/12 Refrigerant Control Expansion Valve Expansion Valve Expansion Valve Expansion Valve Expansion Valve Drain Connection Size (in.) 1 PVC 1 PVC 1 PVC 1 PVC 1 PVC
Indoor Fan - Type Centrifugal Centrifugal — Centrifugal Centrifugal No. Used/Diameter x Width - in. (mm) 1 / 15 x 15 1 / 15 x 15 — 2 / 15 X 15 2 / 15 X 15
(1 / 38.1 x 38.1) (1 / 38.1 x 38.1) — (2 / 38.1 x 38.1) (2 / 38.1 x 38.1) Drive Type/ No. Speeds Belt/Adjustable Belt/Adjustable — Belt/Adjustable Belt/Adjustable CFM (m3/h) 4000 (6796) 4000 (6796) — 6000 (10194) 8000 (13592) No. Motors 1 1 — 1 1 Motor HP (kW) - Standard/Oversized 2.00/— (1.49/2.243) 2.00/3.00 (1.49/2.24) — 3.00/5.00 (2.24/3.72) 5.00/7.50 (3.72/5.59) Motor Rpm 1725 1725 — 1750/1735 1750/3470 Motor Frame Size 56HZ 56HZ — 145T 184T
Filters -
Type/Furnished Throwaway/Yes Throwaway/Yes Throwaway/No2 Throwaway/Yes Throwaway/Yes (No.) Size Recommended - in. [mm] (4) 16 x 25 x 1 (4) 16 x 25 x 1 (4) 16 x 25 x 1 (8) 15 x 20 x 2 (4) 16 x 25 x 2
(4) 16 x 20 x 2 [(4) 40.6 x 63.5 x 2.54] [(4) 40.6 x 63.5 x 2.54] [(4) 40.6 x 63.5 x 2.54] [(8) 38.1 x 50.8 x 5.1] [(4) 40.6 x 63.5 x 5.1]
[(4) 40.6 x 50.8 x 5.1] ARI tested and certified with various heat pumps in accordance with ARI Standard 210/240 or 340/360-93 certification program. Refer to Performance Data section in this catalog.
NOTES:
1. Ships wired for 208-230/3/60. Field convertible to 460/3/60.
2. Coil has filter rack as standard, but no filters. When using this coil as a duct coil, use below size recommended. Filters for coil not recommended when using coil with upflow gas furnaces.
SS-PRC004-EN12
Performance Data (7½ Ton)
Table PD-1 — Gross Cooling Capacities (MBh) 7½ Ton TTA090A Condensing Unit with 7½ Ton TWE090A Air Handler — (I-P)
Ambient Temperature (°F) 85 95 105 115
Enter.
Dry Entering Wet Bulb (°F)
CFM Bulb 61 67 73 61 67 73 61 67 73 61 67 73 Airflow (°F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 83.2 65.7 91.5 55.6 100.3 37.2 80.2 64.2 88.2 54.2 96.6 35.9 77.0 62.6 84.7 52.8 92.8 34.6 73.6 60.8 81.0 51.4 88.8 33.3 2700 80 83.7 76.7 91.9 63.5 100.5 48.8 80.8 75.2 88.4 61.7 96.9 47.5 77.7 73.6 84.9 60.1 93.2 46.1 74.5 71.9 81.3 58.5 89.4 44.7
85 85.6 85.61 92.1 74.1 100.9 60.3 83.1 83.11 88.8 72.6 97.3 58.9 80.4 80.41 85.4 71.0 93.6 57.5 77.5 77.51 81.8 69.3 89.8 56.1 90 89.9 89.91 92.7 85.1 101.0 71.2 87.3 87.31 89.5 83.6 97.5 69.8 84.5 84.51 86.2 82.1 93.8 68.3 81.6 81.61 82.8 80.5 90.1 66.7 75 84.8 68.6 93.1 53.9 101.8 37.8 81.7 67.1 89.7 52.5 98.0 36.5 78.4 65.4 86.1 51.0 94.0 35.2 74.9 63.7 82.3 49.5 89.9 33.7
3000 80 85.5 80.6 93.3 65.8 102.1 50.4 82.5 79.1 89.9 64.3 98.4 49.1 79.4 77.5 86.4 62.7 94.6 47.7 76.1 75.8 82.7 61.0 90.7 46.3 85 88.2 88.21 93.7 77.7 102.5 62.9 85.7 85.71 90.4 76.2 98.9 61.5 82.8 82.81 86.8 74.6 95.1 60.1 79.9 79.91 83.2 72.9 90.9 58.2 90 92.7 92.71 94.6 89.8 102.7 74.6 90.0 90.01 91.4 88.3 99.1 73.1 87.1 87.11 88.0 86.8 95.3 71.6 84.1 84.11 84.2 84.21 91.5 70.1 75 86.1 71.4 94.4 55.6 103.0 38.5 82.9 69.8 90.9 54.2 99.1 37.1 79.6 68.1 87.2 52.7 95.0 35.7 76.0 66.3 83.4 51.2 90.9 34.2
3300 80 87.1 84.5 94.6 68.3 103.4 51.9 84.1 82.9 91.2 66.8 99.6 50.5 80.5 80.51 87.6 65.2 95.8 49.2 77.5 77.51 83.8 63.5 91.8 47.7 85 90.6 90.61 95.1 81.1 103.8 65.3 87.9 87.91 91.7 79.6 99.9 63.5 84.9 84.91 88.1 78.0 96.0 62.0 81.9 81.91 84.4 76.4 92.1 60.5 90 95.2 95.21 96.3 94.3 104.1 77.8 92.3 92.31 93.1 92.8 100.4 76.3 89.4 89.41 89.4 89.41 96.6 74.8 86.3 86.31 86.4 86.41 92.7 73.2 75 87.2 74.0 95.5 57.3 104.0 38.9 84.0 72.4 91.9 55.8 100.0 37.5 80.6 70.7 88.2 54.3 95.9 36.1 77.0 68.9 84.0 52.3 91.7 34.7
3600 80 88.6 88.1 95.8 70.7 104.5 53.3 85.2 85.21 92.3 69.2 100.7 52.0 82.3 82.31 88.6 67.5 96.7 50.6 79.2 79.21 84.7 65.8 92.7 49.2 85 92.6 92.61 96.3 84.5 104.8 67.2 89.8 89.81 92.9 82.9 101.0 65.7 86.8 86.81 89.3 81.3 97.1 64.2 83.6 83.61 85.5 79.7 93.1 62.6 90 97.3 97.31 97.4 97.4 105.3 80.9 94.4 94.41 94.5 94.51 101.5 79.4 91.4 91.41 91.4 91.41 97.6 77.9 88.2 88.21 88.3 88.31 93.7 76.3
NOTES:
1. Dry coil condition. Total Gross Cooling Capacity (MBh) shown to the left is not applicable. In this case the Sensible Heat Capacity (SHC) is the total capacity.
All capacities shown are gross and have not considered indoor fan heat.
To obtain net cooling capacities subtract indoor fan heat.
MBH = Total Gross Cooling Capacity SHC = Sensible Heat Capacity
Table PD-1a — Gross Cooling Capacities (kW) 7½ Ton TTA090A Condensing Unit with 7½ Ton TWE090A Air Handler — (SI)
Ambient Temperature (°C)
29.4 35.0 40.6 46.1
Enter.
Dry Entering Wet Bulb (°C) m3/h Bulb 16.1 19.4 22.8 16.1 19.4 22.8 16.1 19.4 22.8 16.1 19.4 22.8 Airflow (°C) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC
24 24.4 19.2 26.8 16.3 29.4 10.9 23.5 18.8 25.8 15.9 28.3 10.5 22.6 18.3 24.8 15.5 27.2 10.1 21.6 17.8 23.7 15.0 26.0 9.7 4586 27 24.5 22.5 26.9 18.6 29.4 14.3 23.7 22.0 25.9 18.1 28.4 13.9 22.8 21.6 24.9 17.6 27.3 13.5 21.8 21.1 23.8 17.1 26.2 13.1
29 25.1 25.1 27.0 21.7 29.5 17.6 24.3 24.3 26.0 21.2 28.5 17.3 23.5 23.5 25.0 20.8 27.4 16.8 22.7 22.7 23.9 20.3 26.3 16.4 32 26.3 26.3 27.1 24.9 29.6 20.8 25.6 25.6 26.2 24.5 28.5 20.4 24.8 24.8 25.2 24.0 27.5 20.0 23.9 23.9 24.2 23.6 26.4 19.5 24 24.8 20.1 27.3 15.8 29.8 11.1 23.9 19.6 26.3 15.4 28.7 10.7 23.0 19.2 25.2 14.9 27.5 10.3 21.9 18.6 24.1 14.5 26.3 9.9
5098 27 25.0 23.6 27.3 19.3 29.9 14.8 24.2 23.2 26.3 18.8 28.8 14.4 23.2 22.7 25.3 18.4 27.7 14.0 22.3 22.2 24.2 17.9 26.5 13.5 29 25.8 25.8 27.4 22.7 30.0 18.4 25.1 25.1 26.5 22.3 28.9 18.0 24.3 24.3 25.4 21.8 27.8 17.6 23.4…
This is the start of the file's text. The full file is on GovTribe.